HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0050.2018 (2).ARBKfantech
Ventilation Solutions
Laundries
05/22/2018
fantech
2 | Laundries
A New Day - and a New Name
for Dryer Exhaust Fans
Indicator panel
FC 4
Mounting clamps
Remember the good old days when laundry spaces were
designed so that clothes dryers could be vented directly
through an exterior wall with just a few feet of straight
duct? Those days are over. Influenced by the latest laundry
room trends (including proximity to bedrooms, multi-func-
tion capability, elaborate storage and fixtures, etc.)
builders and contractors are faced with a challenging
task to provide proper and effective dryer ventilation.
05/22/2018
fantech
Laundries | 3
Dryer Exhaust Duct Power
Ventilator
DBF 4XLT-705
Dryer location preferences often result in longer dryer exhaust duct runs
with multiple bends that reduce dryer efficiency, extend drying time and
interfere with a builder’s ability to comply with the building code. A properly
applied dryer exhaust fan, preferably one that is UL Listed, may be the only
solution that makes everyone happy – including the home inspector and the
local fire chief.
The 2012 International Residential Code (IRC) is pretty specific when
it comes to dryer exhaust venting. A dryer exhaust duct system cannot
exceed 35 feet from the dryer location to the wall or roof termination.
Each 90-degree elbow reduces this maximum allowable length by 5 feet.
Additionally, each dryer has its own specifications for exhaust duct length
(often consi- derably shorter than 35 feet). Contractors should refer to the
dryer manufacturer’s instructions to make sure the dryer exhaust duct length
does not exceed a particular model’s capability. Given these restrictions, it is
likely that dryers located in interior spaces will exceed either the IRC’s or the
dryer manufacturer’s limits on duct length.
For years, dryer exhaust fans have been successfully used in homes and
multi-family buildings with long dryer exhaust duct runs. Many homeowners,
previously burdened with long drying times and perpetually damp clothes,
have been delighted with the results.
Underwriters Laboratories (UL) has deve-
loped a supplement to UL705 specifically for
fans used for dryer exhaust and has given
these fans a new name:
Dryer Exhaust Duct Power Ventilator
(DEDPV).
05/22/2018
fantech
4 | Laundries
Model DBF 4XLT-705 allows for 4"
dryer exhaust duct runs up to 130 feet
and is UL listed per the DEDPV Supplement to
UL Standard 705.
Model DBF 4XLT-705 is equipped with an advanced
pressure sensing circuit, LED indicator display panel,
temperature limit device and fast clamps for easy
installation and maintenance.
MORE THAN
JUST A DRYER
EXHAUST FAN..
4 | Laundries
fantech
05/22/2018
fantech
Laundries | 5
Model DBF 4XLT-705 allows for 4"
dryer exhaust duct runs up to 130 feet
and is UL listed per the DEDPV Supplement to
UL Standard 705.
Model DBF 4XLT-705 is equipped with an advanced
pressure sensing circuit, LED indicator display panel,
temperature limit device and fast clamps for easy
installation and maintenance.
Laundries | 5
fantech
IT'S A UL
LISTED
DEDPV
05/22/2018
fantech
6 | Laundries
While fans of another name may be installed in dryer exhaust applications (at least for now) UL has
announced that all Dryer Exhaust Duct Power Ventilators “DEDPV” products manufactured after July 31,
2012 must comply with the supplementary DEDPV requirements of UL705.
The UL testing standards for DEDPV’s help to ensure that dryer exhaust fans can safely and effectively
assist the ventilation of a residential capacity dryer. The standard’s tests prove functionality of required
safety features, provisions for maintenance, proper air velocities for lint management, etc.
UL’s DEDPV standard has established a baseline for dryer exhaust fans. Authorities with jurisdiction can
now require UL Listed DEDPVs for installations in their communities. As well, architects
and engineers can specify UL Listed DEDPVs for their projects, knowing that the safety
of these installations is backed by a globally-recognized, independent testing and
standards company.
Distinguishing features between DEDPVs
and other dryer exhaust fans
A DEDPV must indicate proper fan operation to the
dryer operator as well as notify the dryer operator
in the event of a fan failure.
DEDPVs are most notably differentiated from
other dryer exhaust fans by these features:
A DEDPV must automatically energize when the
dryer is operated. An integral pressure switch may
be used to sense dryer operation and energize
the fan.
DEDPV fan housings must be metal, never plastic.
A DEDPV must also shut down in the event of a
dryer fire, so as not to facilitate the spread of fire
in the home.
05/22/2018
fantech
Laundries | 7
DBF 4XLT-705
Dryer Exhaust Duct Power Ventilator
• UL Listed as a DEDPV under UL705
• Indicator panel for fan operation is included
• Temperature limit device shuts down the fan in case of a dryer fire
• Airtight, galvanized steel housing ensures no leakage into the building
• Integral pressure switch for automatic operation
• Maintains 1,200 FPM air velocity: lint is entrained in the flowing air
The Fantech dryer exhaust duct power ventilator has been specially designed to
solve the problems caused by long duct runs on clothes dryers.
When the dryer is on, Fantech's patented pressure sensing switch automatically
turns the DEDPV on. The DEDPV will turn itself off after the dryer stops. The
wall-mounted indicator panel with a low voltage LED display lets the dryer
operator know that the DEDPV is operating properly. The panel will also alert
the dryer operator of problems such as no power, blocked duct, locked motor
rotor and low speed conditions.
A 50 foot control cable is included to connect the indicator panel to the DEDPV.
The system can be used to effectively exhaust a 4 inch dryer duct run up to 130
feet in length.
Cleaning the dryer
exhaust fan is now
easier and quicker.
Removable duct sleeves
provide for easy access to
the duct and fan impeller.
Specification data
Model
Duct
size
Rated
power
Voltage /
phase
Max.
amps
0.0” Ps 0.2” Ps 0.4” Ps 0.6” Ps 0.8” Ps 1.0” Ps Shipping
weight
Item #
inch W V / ~A cfm lbs
DBF 4XLT-705 4 83 120 / 1 0.73 170 150 134 119 103 86 10 46005
Per HVI`S Certified rating program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at 0.2 inches WG.
Dimensions
1
12 2
1
12
93/4
93/4
33/4
2
3
33/4
615/16
615/16
37/8
37/8
37/8
37/8
Dimensional information is in inches.
05/22/2018
fantech
8 | Laundries
DBF Series
Dryer Exhaust Fans
DBF 110
• Maintains 1,200 FPM air velocity to entrain lint in the flowing air
• Pressure switch to activate the fan when the dryer is on
The DBF 110 dryer exhaust fan is engineered of thermoplastic resin. It can be
used on dryer duct runs up to 108 feet in length. The fan’s backward inclined
impeller blades allow lint to pass through the fan. The fan can be mounted
in any orientiation at any point along the duct run and its straight-through air
flow design allows for easy installation.
Specification data
Model
Duct
size
Rated
power
Voltage /
phase
Max.
amps
0.0” Ps 0.2” Ps 0.4” Ps 0.6” Ps 0.8” Ps 1.0” Ps Shipping
weight
Item #
inch W V / ~A cfm lbs
DBF 4XLT 4 83 120 / 1 0.73 170 150 134 119 103 86 10 40275
DBF 4XL 4 83 120 / 1 0.73 170 150 134 119 103 86 10 40095
DBF 110 4 80 120 / 1 0.72 167 150 133 113 88 63 9 411347
Per HVI`S Certified rating program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at 0.2 inches WG.
DBF 4XLT
DBF 4XL
DBF 4XL and DBF 4XLT
• Airtight, galvanized steel housing ensures no leakage into the building
• Maintains 1,200 FPM air velocity to entrain lint in the flowing duct
• Pressure switch to activate the fan when the dryer is on
• 5 1/2-foot electrical cord with plug and mounting bracket
Both models DBF 4XL and DBF 4XLT are dryer exhaust fans with backward
inclined impeller fan blades, which allow lint to pass through the fan. These
models can be used to provide dryer exhaust in duct runs up to 130 feet in
length.
The DBF 4XLT model also includes a quick connect / disconnect fast clamp,
and wall-mount indicator panel. The LED light on the panel lets the dryer
operator know the fan is working properly.
Dimensions
1
12 2
1
12
93/4
93/4
33/4
2
3
33/4
615/16
615/16
37/8
37/8
37/8
37/8
1
12 2
1
12
93/4
93/4
33/4
2
3
33/4
615/16
615/16
37/8
37/8
37/8
37/8
DBF 4XLDBF 4XLT
Dimensional information is in inches.121/2”
111/4”
91/2”
91/2”
37/8”
DBF 110
DBF 110
05/22/2018
fantech
Laundries | 9
Specification data
Model
Duct
size
Rated
power
Voltage /
phase
Max.
amps
0.0” Ps 0.2” Ps 0.4” Ps 0.6” Ps 0.8” Ps 1.0” Ps Shipping
weight
Item #
inch W V / ~A cfm lbs
RVF 4XL 4 92 120 / 1 0.84 193 172 154 136 118 91 10 40041
Per HVI`S Certified rating program, charted air flow performance has been derated by a factor based on actual test results and the certified rate at 0.2 inches WG.
RVF Series performance is shown with ducted inlet.
Dimensional information is in inches.
RVF 4XL
Exterior-Mount Fan for Dryer Exhausting
RVF 4XL
• Galvanized steel housing features powder-coat finish
• Mounts on the exterior side wall of the building
Fantech’s popular exterior-mount exhaust fan with white, powdercoated metal
housing can be used for dryer exhausting when paired with the accessory
DB10 pressure switch (purchased separately). The accessory pressure switch
automatically energizes the fan when the dryer is operated. Ideal for condos
and apartments as well as homes. Effective for duct runs up to 130 feet in
length.
Dimensions
Model A†B C D E
RVF 4XL 3 7/8 10 1/4 13 6 2 3/4
Air flowA
C
D B
E
05/22/2018
fantech
10 | Laundries
1/3"
21/3"
1/3"
D
DBLT 4W
Lint Trap for Dryer Exhaust Fans
Galvanized metal lint trap for dryer exhausting
applications. Use when duct length between
dryer and exhaust fan is less than 15 feet. Fits
4-inch duct and 2”x 6” construction. Features
pull out a white pull-out door with a view
window with attached removable lint filter for easy cleaning and 1/2” flange
for flush mount installation. The lint trap complements all Fantech dryer
exhaust fans.
Specification Data
Model Duct Size,
inch
Accessibility Weight,
lbs
Item #
DBLT 4W 4 Door 4 46000
DB 10
Pressure Switch
Provides fully automatic operation of
dryer exhaust fan. Fan runs for 10 minutes
when positive pressure is sensed in the
duct line then shuts off and turns on again
as needed. The switch is required for use
with fan model RVF 4XL when used in a dryer
exhaust application.
Specification Data
Model Voltage,
V
Max Current,
A
Weight,
lbs
Item #
DB 10 120 2 1 411110
FC
Fast Clamps
Our Fast Clamps facilitate the installation and
removal of fans for service and cleaning. Made
from galvanized sheet steel and fitted with an
1/3” neoprene lining, which suppresses vibration
and ensures a tight fit. The mounting clamps are
fastened together by two screws, which allow for
connecting ducts with a marginal difference in diameter. Sold in pairs.
Model øD Neoprene
lining, inch
Weight,
lbs
Item #
FC 4 4 1/3 1 411295
FC 5 5 1/3 1 411108
Dimensions
Accessories
for Dryer Exhaust Fans
Specification Data
Dimensional information is in inches.
05/22/2018
fantech
Laundries | 11
DID YOU KNOW..
Laundries | 11
That according to the National Fire
Prevention Association (NFPA), the
leading cause of home fires is from
lint ignition in the dryer or dryer
duct?
A DEDPV or Dryer Booster from Fantech maintains
an airflow that keeps lint suspended while
exhausting it to the outside, thereby reducing the
risk of fire.
That Spontaneous Combustion
can occur in the dryer after the
dryer stops due to high heat and no
airflow?
The DEDPV continues to operate for a short
period of time after the dryer stops which
cools the clothes and lessens the risk of
spontaneous combustion.
Dryers don't have an indicator to
tell if there is a build up of lint in the
duct?
A safety feature of the DBF4XLT and
DBF4XLT-705 is a visual indicator panel. This
provides the user with a visual indication of
correct operation or indication of a pressure
increase due to a blocked duct. This advanced
warning allows the user to take action to
clean the dryer exhaust duct.
That most dryers are limited to a
duct run of 35'?
Using a DEDPV or Dryer Exhaust Fans can
increase the duct run up to 130 feet, as the
fan relieves the pressure in the extended duct
allowing the dryer to work efficiently.
Dryer Exhaust Duct
Power Ventilator
DBF 4XLT-705
05/22/2018
Systemair Inc. • September, 2014 • Art. 412038 Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features,
designs, components and specifications to maintain their technological leadership position. The application
rendering presented in this brochure is for visual presentation purposes only. Please, contact a building
professional for technical guidance.
Customer Support:
Canada 800.565.3548 • USA 800.747.1762 • support@fantech.net
Send Orders:
Canada 877.747.8116 • USA 800.487.9915 • orders@fantech.net
05/22/2018