Loading...
HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0050.2018 (16).ARBKPHASE CON ENVIRONMENTAL CONSULTANTS Final Clearance Air Monitoring Services Date: May 8, 2018 Project: Abatement of ACM ceiling texture by demolition of the ceiling wallboard at North of Nell Condominiums, Unit 3E, Aspen, Colorado. Contractor: Prestige Environmental Services, Aurora, Colorado Air Monitoring Description: Phase Con provided final clearance air monitoring services at the project site listed above on May 8, 2018. Air samples were situated inside the enclosure so as to be representative of the entire work space. Air samples were obtained utilized aggressive sampling methods to aid in ensuring that any fibrous material left in the enclosure would be entrained in the air during the sampling period. Abatement Description: Abatement of ACM ceiling texture by demolition of the ceiling wallboard. Comments and Recommendations: PCM analysis of the final clearance air samples revealed airborne fiber levels inside the containment area(s) to be less than the Colorado State Maximum Allowable Asbestos Level (MAAL) and the EPA clearance level of 0.010 fibers per cubic centimeter of air; therefore, the area(s) may be re-occupiefl under non -abatement conditions. Douglas A. Close /Colorado State Air Monitoring Specialist #2930 2166 peregrine Court Grand Junction, CO 81507 Office: 9 0-260-3341 pceconsultaritsCagwestoffice.net PHASE CON ENVIRONMENTAL CONSULTANTS PCM LABORATORY ANALYSIS OSHA Reference Method - NIOSH 7400 Client: North of Nell Condominium Assoc. Sampling Date: 5/08/18 Aspen, Colorado Technician/Analyst: D. Close Project: North of Nell Condos, Unit 3E CDPHE Technician ID: 2930 Aspen, Colorado Abatement Contractor: Prestige Environmental Services, Aurora, Colorado Description of Work: Abatement of ACM ceiling texture by demolition of the Ceiling wallboard. SAMPLE SAMPLE DESCRIPTION ID AIR VOLUME fibers/fields f/cc 01 Final Clearance Sample - 546 L 6.5/100 Ceiling Demolition Enclosure <0.006 f/cc 02 Final Clearance Sample - 546 L 5.0/100 Ceiling Demolition Enclosure <0.006 F/CC 03 Final Clearance Sample - 546 L 5.0/100 Ceiling Demolition Enclosure <0.006 F/CC 04 Final Clearance Sample - 546 L 5.0/100 Ceiling Demolition Enclosure <0.006 F/CC 05 Final Clearance Sample - 546 L 6.5/100 Ceiling Demolition Enclosure <0.006 F/CC 06 Blank ----- NONE DETECTED 07 Blank ----- NONE DETECTED * Colorado State Clearance Level is 0.010 f/cc of air —_.., Technician/Analyst: .i- 2166 Peregrine Court Grand unction, CO 81507 Office: 970-260-3341 pceconsultaiits@)gwestoffice.net Certificates Colorado Department of Public Health and Environment ASBESTOS CERTIFICATION* This certifies that Douglas A. Close Certification No.: 2930 has met the requirements of ?5-7-507, C.R.S. and Air Quality Control Commission Regulation No. 8, Part B, and is hereby certified by t11e state of Colorado in the following discipline: Air Monitoring Specialist* Issued: November 011 201? Expires: December 08, 2018 ,� This cerlilicule is valid oniv with the possession 4"1 current Division -approved lruinin!; coll-c ccrli/icutiort in rile discipline speci/ied above. Autt.orized APCD Representative SEAL