HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0050.2018 (16).ARBKPHASE CON
ENVIRONMENTAL CONSULTANTS
Final Clearance Air Monitoring Services
Date: May 8, 2018
Project: Abatement of ACM ceiling texture by demolition of the ceiling
wallboard at North of Nell Condominiums, Unit 3E, Aspen, Colorado.
Contractor: Prestige Environmental Services, Aurora, Colorado
Air Monitoring Description:
Phase Con provided final clearance air monitoring services at the project
site listed above on May 8, 2018. Air samples were situated inside the
enclosure so as to be representative of the entire work space. Air
samples were obtained utilized aggressive sampling methods to aid in
ensuring that any fibrous material left in the enclosure would be
entrained in the air during the sampling period.
Abatement Description:
Abatement of ACM ceiling texture by demolition of the ceiling wallboard.
Comments and Recommendations:
PCM analysis of the final clearance air samples revealed airborne fiber
levels inside the containment area(s) to be less than the Colorado State
Maximum Allowable Asbestos Level (MAAL) and the EPA clearance level
of 0.010 fibers per cubic centimeter of air; therefore, the area(s) may
be re-occupiefl under non -abatement conditions.
Douglas A. Close
/Colorado State Air Monitoring Specialist #2930
2166 peregrine Court
Grand Junction, CO 81507
Office: 9 0-260-3341 pceconsultaritsCagwestoffice.net
PHASE CON
ENVIRONMENTAL CONSULTANTS
PCM LABORATORY ANALYSIS
OSHA Reference Method - NIOSH 7400
Client: North of Nell Condominium Assoc. Sampling Date: 5/08/18
Aspen, Colorado Technician/Analyst: D. Close
Project: North of Nell Condos, Unit 3E CDPHE Technician ID: 2930
Aspen, Colorado
Abatement Contractor: Prestige Environmental Services, Aurora, Colorado
Description of Work: Abatement of ACM ceiling texture by demolition of the
Ceiling wallboard.
SAMPLE SAMPLE DESCRIPTION
ID
AIR VOLUME fibers/fields
f/cc
01
Final Clearance Sample -
546 L
6.5/100
Ceiling Demolition Enclosure
<0.006 f/cc
02
Final Clearance Sample -
546 L
5.0/100
Ceiling Demolition Enclosure
<0.006 F/CC
03
Final Clearance Sample -
546 L
5.0/100
Ceiling Demolition Enclosure
<0.006 F/CC
04
Final Clearance Sample -
546 L
5.0/100
Ceiling Demolition Enclosure
<0.006 F/CC
05
Final Clearance Sample -
546 L
6.5/100
Ceiling Demolition Enclosure
<0.006 F/CC
06
Blank
-----
NONE
DETECTED
07
Blank
-----
NONE
DETECTED
* Colorado State Clearance Level is 0.010 f/cc of air
—_..,
Technician/Analyst:
.i-
2166 Peregrine Court
Grand unction, CO 81507
Office: 970-260-3341 pceconsultaiits@)gwestoffice.net
Certificates
Colorado Department
of Public Health
and Environment
ASBESTOS
CERTIFICATION*
This certifies that
Douglas A. Close
Certification No.: 2930
has met the requirements of ?5-7-507, C.R.S. and Air Quality Control
Commission Regulation No. 8, Part B, and is hereby certified by t11e
state of Colorado in the following discipline:
Air Monitoring Specialist*
Issued: November 011 201?
Expires: December 08, 2018
,� This cerlilicule is valid oniv with the possession 4"1
current Division -approved lruinin!; coll-c ccrli/icutiort
in rile discipline speci/ied above.
Autt.orized APCD Representative