HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0120.2017 (4).ARBKLochinvar.com HIGH EFFICIENCY CONDENSING BOILERS REMOTE CONNECT CAPABLE OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER 7 MODELS: 55,000 – 399,999 BTU/HR 5:1 TURNDOWN RATIO LESS THAN 20 ppm NOx DIRECT VENT FLEXIBILITY TO 100 FEET 95% AFUE Efficiency *See back page for efficiency by model Received 6/13/17 The KNIGHT® Wall Mount, engineered with Lochinvar’s exclusive SMART SYSTEM™ control and an array of other innovative features is far ahead of any heating boiler in its class. It promises and delivers ultimate ease of installation and maintenance. With up to 99% efficiency, low-NOx emissions and a fully modulating burner, it is the best ”green choice” for today’s environmentally focused market. Seven modulating/condensing stainless steel KNIGHT Wall Mount boilers are available with 55,000–399,999 Btu/hr inputs in a space- saving wall-mounted design. All are equipped for direct-vent installation with air intake and exhaust runs up to 100 feet using PVC, CPVC, Polypropylene or AL29-4C vent materials. This range of choices is ideal for residential or light-duty applications such as small hotels, schools and office buildings. For higher-demand applications, up to eight KNIGHT Wall Mount units can be installed utilizing the built-in cascading sequencer to deliver up to 3.2 million Btu/hr heating capacity. The KNIGHT Wall Mount Boiler reflects Lochinvar’s constant commitment to providing all the options you need to serve every application. Advanced Negative Regulation Technology KNIGHT safely and reliably operates with supply gas pressure as low as 4 inches water column. Negative Regulation (Neg/Reg) technology automatically adjusts fan speed to ensure the correct volume and mix of fuel and air throughout the firing range. Fire Tube Design This fully welded ASME Certified stainless steel heat exchanger uses oval shaped tubes to pass heat from the products of combustion into the water stored in the vessel. To facilitate heat transfer the tubes are manufactured with dimples to slow the flue products and extract available latent energy. With a fire tube design the flue products are inside tapered passage ways and the water is passed through the vessel. Since the flue products pass through tubes and the water is circulated through a larger diameter vessel a fire tube design allows for minimal head pressure loss through the boiler which allows the boiler to be installed easily into various hydronic applications. Water-Backed Combustion Chamber An outstanding feature of the fire tube design is a water backed combustion chamber. By having the combustion chamber surrounded by water the Knight Wall Mount has more heating surface area. This larger heating surface area allows for efficiencies up to 99%. Fully Modulating Burner The SMART SYSTEM allows fully modulating combustion with 5:1 turndown. The burner can fire as low as 20% of maximum input and modulates the firing rate up to 100% as demand increases. The burner is a single stainless steel assembly covered with woven steel mesh and fires in a 360° pattern along the entire length of the burner. This allows the compact KNIGHT to exceed the modulation capacities of units with larger multiple burners. The Smartest Choice for Condensing Boiler Performance KNIGHT offers 5 venting options and tremendous flexibility for placement of units within the building, because it permits direct-vent air intake and exhaust runs up to 100 equivalent feet using either PVC, CPVC, Polypropylene or AL29-4C stainless steel vent pipe. Direct Venting up to 100 Feet Direct Vent Vertical Concentric Direct Vent Vertical*Direct Vent Sidewall Concentric Direct Vent Sidewall*Vertical w/Sidewall Air *Optional Vent Kit Sold Separately 5 Flexible Venting Options Received 6/13/17 • multi-color graphic lcd display • navigation dial • usb port • ability to control up to three different setpoint temperatures • compatibility with copper-fin ii non-condensing boiler to create a front-end loading system • boilers with different inputs can be cascaded together to maximize boiler plant turndown • modbus capability (optional) • dhw modulation limiting • dhw night setback* • 0-10 v boiler rate output • 0-10 v signal to control variable speed boiler pump* • 0-10 v system pump signal input* • heat demand from 0-10v input • installer can program name and number into the boiler • installer adjustable freeze protection parameters • separately adjustable sh/dhw switching times* • installer access to bms and ramp delay settings *Exclusive to Lochinvar Smart System Refined Design Puts More Control and Information at your Fingertips Advanced features include: Lead-Lag Cascade The “lead” boiler modulates with demand to capacity. As demand increases, additional boilers fire and modulate to capacity. This continues, with additional boilers firing and modulating to capacity until all units are operating. Every 24 hours, the SMART SYSTEM automatically shifts the lead boiler role to the next in the sequence, distributing lead-lag runtimes equally. Efficiency Optimized Cascade This feature optimizes the modulation capabilities of the Boiler Plant while evenly distributing run time across all cascaded boilers. Every 24 hours the SMART SYSTEM automatically shifts the 1st boiler on role to the next in the sequence, distributing run time equally. SMART SYSTEM Cascade allows 2 - 8 boilers to be sequenced. New Selectable Cascade Options When multiple KNIGHT boilers are installed together, the SMART SYSTEM built-in sequencer can be set for “Lead-Lag” cascade or “Efficiency Optimized” cascade operation. At-a-Glance Color Coding yellow screen Maintenance due - shows the installer’s name and number on the display. red screen Lockout mode. blue screen Normal system operation. ® REMOTE CONNECT ® REMOTE CONNECT The CON·X·US mobile communication platform allows SMART SYSTEM to go where no other boiler has gone before.† CON·X·US provides the ability to monitor and manage multiple Knight heating boilers without ever stepping into the mechanical rooms. CON·X·US will send alerts via text or e-mail notifying of changes in system status, and anytime, from anywhere, a user can check system status and re-program any boiler function. Once downloaded, the free CON·X·US mobile application allows for remote access to all SMART SYSTEM functions using an Internet-capable device. †CON·X·US control board sold separately. Received 6/13/17 WHN-04 (Reprint WHN-04 05/16) PDP-5M-12/16-Printed in U.S.A. Smart System™ Features > SMART SYSTEM Digital Operating Control Multi-Color Graphic LCD Display with Navigation Dial and Soft Keys > Three Boiler Setpoint Temperature Inputs Plus Domestic Hot Water Prioritization > Built-in Cascading Sequencer for up to 8 Boilers Multiple Size Boiler Cascade Lead Lag Efficiency Optimization Front End Loading Capability with Copper Fin II > Outdoor Reset Control with Outdoor Air Sensor Programmable for Three Reset Temperature Inputs > Programmable System Efficiency Optimizers Night Setback DHW Night Setback* Anti-Cycling Outdoor Air Reset Curve Ramp Delay Boost Temperature & Time > Three Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable Speed Pump Control* Domestic Hot Water Pump > Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the Smart System DHW Modulation Limiting Separately Adjustable Space Heat/DHW Switching Times* > Building Management System Integration 0-10 VDC Input to Control Modulation or Set Point 0-10 VDC Modulation Rate Output 0-10 VDC Input to Enable/Disable call for heat > Access to BMS Settings through Graphic LCD Display > High-Voltage Terminal Strip 120 VAC / 60 Hertz / 1 Phase Power Supply Three Sets of Pump Contacts > Low Voltage Terminal Strip 24 VAC Device Relay Proving Switch Contacts Flow Switch Contacts Alarm on Any Failure Contacts Runtime Contacts DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10 VDC BMS External Control Contact 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Variable Speed System Pump Signal Input* 0-10 VDC Signal to Control Variable Speed Boiler Pump* Modbus Contacts > Time Clock > Data Logging Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts > Maintenance Reminder Custom Maintenance Reminder with Contractor Contact Information Installer Ability to De-activate Service Reminder > Low-Water Flow Safety Control & Indication > Password Security > Customizable Freeze Protection Parameters Standard Features > ENERGY STAR Most Efficient Recognition§ > 95% DOE AFUE Efficiency§ > Modulating Burner with 5:1 Turndown Direct-Spark Ignition Low-NOx Operation Field Convertible from Natural to LP Gas > ASME Stainless Steel Heat Exchanger 30 psi ASME Relief Valve > Vertical & Horizontal Direct-Vent PVC, CPVC, Polypropylene or SS Venting up to 100 feet > Smart System Control > Condensate Trap > Other Features Automatic Reset High Limit Adjustable High Limit w/Manual Reset Boiler Circulating Pump Wall-Mount Bracket Zero Clearances to Combustible Materials 12-Year Limited Warranty (See Warranty for Details) 5-Year Parts Warranty Optional Equipment CON·X·US Remote Connectivity Modbus Communication Flow Switch Low-Water Cutoff w/Manual Reset & Test Alarm Bell Concentric Vent Kit Condensate Neutralization Kit BMS Gateway to LON or BacNet Multi-Temperature Loop Control Sidewall Vent Termination Floor Stand Wireless Outdoor Sensor Firing Codes > M9 Standard Construction > M7 California Code * Exclusive feature, available only from Lochinvar § WHN 55-285 only Input Heating Net AHRI Model Max. Min. *AFUE Capacity Rating Number MBH MBH % MBH MBH MBH WHN055 55 11 95.0 51 44 WHN085 85 17 95.0 79 69 WHN110 110 22 95.0 102 89 WHN155 155 31 95.0 144 125 WHN199 199.9 40 95.0 185 161 WHN285 285 57 95.0 264 229 WHN399 399 80 94.4 377 328 A B C D E F G H I J K L M N O Gas Water Air Vent Shipping Conn. Conn. Inlet Size Wt. (lbs.) 33-1/4” 18-1/2” 16” 11-3/4” 10-1/2” 6-1/2” 4” 1-1/2” 3” 14-1/2” 5-3/4” 4” 3” 16-1/4” 5” 1/2” 1” 2” 2” 139 33-1/4” 18-1/2” 16” 11-3/4” 10-1/2” 6-1/2” 4” 1-1/2” 3” 14-1/2” 5-3/4” 4” 3” 16-1/4” 5” 1/2” 1” 2” 2” 142 33-1/4” 18-1/2” 19” 14-1/2” 10-3/4” 7-3/4” 7-3/4” 2-1/4” 10” 15-1/2” 5” 3-1/4” 3” 16-1/2” 2-3/4” 1/2” 1” 3” 3” 159 33-1/4” 18-1/2” 19” 14-1/2” 10-3/4” 7-3/4” 7-3/4” 2-1/4” 10” 15-1/2” 5” 3-1/4” 3” 16-1/2” 2-3/4” 1/2” 1” 3” 3” 166 33-1/4” 18-1/2” 19” 14-1/2” 11-3/4” 8” 8” 1-1/4” 10” 16-3/4” 4-3/4” 3-1/4” 2-3/4” 16-1/2” 3” 1/2” 1-1/4” 3” 3” 175 33-1/4” 18-1/2” 19” 14-1/2” 11-3/4” 8” 8” 1-1/4” 10” 16-3/4” 4-3/4” 3-1/4” 2-3/4” 16-1/2” 3” 1/2” 1-1/4” 3” 3” 184 35-1/2” 25” 21-3/4” 17-1/2” 12-1/2” 9-1/4” 9-1/2” 2-1/4” 13-1/4” 21-1/2” 9” 4-3/4” 4” 22-1/2” 3-3/4” 3/4” 1-1/2” 4” 4” 213 Notes: Indoor installation only. All information subject to change. Change "N" to "L" for LP gas models. *WHN399 value is Thermal Efficiency *The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. Knight Heating Boiler Dimensions and Specifications Knight® ® Wall-Mount Boiler Dimensions and Specifications Patent Pending Top Right Bottom Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com *Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. *The ratings have been determined under the provisions governing forced draft burners. Received 6/13/17