HomeMy WebLinkAboutFile Documents.535 E Hyman Ave.0045.2019 (4).ACBK877.772.7775myflowater.com
FLOWATER REFILL STATIONS
GENERAL
Indoor/outdoor stand-alone, refrigerated, 7x purified
water Refill Station. Refill Stations require 1” clearance
(5” recommended) from walls and/or structures and
must be placed under cover when outdoors.
No direct sunlight.
CERTIFICATIONS/STANDARDS
ISO 9001NSF/ANSI 42, 53 & 58
NSF/ANSI 42: ensures that chlorine, taste, odor, and
particulates are filtered out. NSF/ANSI 53: ensures
health-related contaminants are filtered out.
NSF/ANSI 58: ensures fluoride, chromium, nitrates, and
TDS are reduced.ADA Compliant: These Refill Stations comply with the
requirements of the ADA (Americans with Disabilities Act).
FEED WATER
Refill Stations have been designed and built to purify
municipal tap water most efficiently at 70 psi. Refill
Stations are designed to operate on 50 psi to 100 psi
supply line pressure. If inlet pressure is above 100 psi, a
pressure regulator must be installed in the supply line.
Any damage caused by reason of connecting this
product to supply line pressure slower than 50 psi or
higher than 100 psi is not covered under FloWater’s
service policy. Refill Stations are designed to operate in
ambient temperatures 40°F~104°F (ambient
temperatures greater than 104°F can result in damage
to the carbon and advanced osmosis filters). Refill
Stations should be placed indoors if ambient
temperatures ever drop below 32°F. Any damage
caused by exposure to ambient temperatures below
32°F is not covered under FloWater’s service policy.
Operate only in non condensing humidity. Refill
Stations are prepped with a 1/4” John Guest quick-
connect fitting located in rear, lower left of unit and
require a 1/4” waterline. A water shut-off valve located
behind should be installed.
DRAIN WATER
Advanced Osmosis: Refill Stations utilizing advanced
osmosis require a drain. Advanced osmosis product
water to bypass water is a 1:2 ratio at 70 psi.
Lower water pressure results in lower
advanced osmosis efficiency. Refill Stations are
prepped with a 1/4”John Guest quick-connect fitting
located in rear, lower left of unit and require 1/4”
drain line. Depending on local plumbing codes,
FloWater may install an FDA and NSF certified check
valve/backflow preventer on the drain line. Drain lines
can be run up to 10’ vertically and 100’ horizontally
with system pressure.
SPECIFICATIONS
PURIFICATION
Refill Stations use a 7x purification system, including: a
sedi-carbon filter, carbon filter, advanced osmosis,
coconut carbon filter, mineral filter, alkaline filter, and
activated oxygen. This purification system has been
designed to handle hard water, but may require
more regular advanced osmosis or UF filter changes.
CHILLING SYSTEM
Chilling Capacity:
33.8°F~34.7°F
32.9°F~35.6°F (factory default)
35.6°F~42.8°F
37.4°F~44.6°F
Chilling capacity of drinking water based upon 80°F inlet
water and 90°F ambient. The reserve tank that feeds the
chilling tank is five gallons. The chilling tank is two gallons.Power Draw:
119.3 volts, 0.29 Amps, 30 Watts, 60 Hz (compressor off). 121 volts, 2.5 Amps, 165 Watts 60 Hz
(compressor running)Motor Compressor: Hermetically sealed, rotating type,
110~115VAC, 60Hz single phase. Sealed-in lifetime oil
supply. Equipped with electric cord and three prong
(grounded) molded rubber plug.Condenser: Air-cooled condenser with steel wire tube.
Tube emits heat in natural ambient air. Cooling Unit:
Combination tube-tank type. Tube portion is continuous
coil of copper tubing. Tank is stainless steel. Fully insulated
with EPS foam which meets Underwriters Laboratories
Inc. requirements for self-extinguishing material.Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for trouble-free
operation. It is an environmentally friendly refrigerant gas.Temperature Control: Enclosed adjustable thermostat is
initially set to maintain water temperature between
32.9°F and 35.6°F. Requires no adjustment other than for
altitude requirements. See Chilling Capacity section for
available temperature ranges.
ADA COMPLIANCE
FloWater Refill Stations comply with ADA reach
requirements with a maximum reach of 48".
05/20/2019
877.772.7775myflowater.com
PREMIUM REFILL STATIONS
INSTALLATION
Installation with Advanced OsmosisInstallation with UF Filter
WaterSource Water In
Ball Valve
FLOWATER REFILL STATIONS
AO
05/20/2019
877.772.7775myflowater.com
FLOWATER REFILL STATIONS
DIMENSIONS
68"
48"
18" 16"
Note: If placing a Refill Station in an enclosed cabinet, please leave 3" clearance on each side, and 6" clearance to
the rear. Ensure that there is sufficient venting.05/20/2019
877.772.7775myflowater.com
FLOWATER REFILL STATIONS
DIMENSIONS
ADA Reach Compliance: Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220
mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or ground.05/20/2019