HomeMy WebLinkAboutFile Documents.535 E Hyman Ave.0080.2018.ACBK0080-2018-ACBK_BuildingComment1 Subject: PlanCheck Page Label: A00.05 ACCESSIBLE PATH REFERENCE PLAN Author: justinh File Name: PlanSet.535 E Hyman Unit 108.2018.06.pdf Show a parallel approach clear space at the cashwrap station. PlanSet.535 E Hyman Unit 108.2018.06.pdf (5) Subject: PlanCheck Page Label: A00.05 ACCESSIBLE PATH REFERENCE PLAN Author: justinh File Name: PlanSet.535 E Hyman Unit 108.2018.06.pdf The boulder is obstructing your accessible route in this location, please revise. Subject: PlanCheck Page Label: A80.03 INTERIOR ELEVATIONS Author: justinh File Name: PlanSet.535 E Hyman Unit 108.2018.06.pdf The accessible fitting room bench should be shown in the interior elevation to demonstrate proper seat and back support height per 2009 ANSI section 903. If any coat racks or hooks are proposed then at least one of each type shall be provided within an accessible reach range per ANSI 803.5. It should also be dimensioned in plan view where shown elsewhere to show compliance with the sizing requirements of ANSI 903. Subject: PlanCheck Page Label: A90.02 COMPONENTS Author: justinh File Name: PlanSet.535 E Hyman Unit 108.2018.06.pdf Dimension the height of the cashwrap station on the elevations to show compliance with ANSI 904. B N.I.S. 3' - 0" 2' - 10" 3/8" = 1'-0"A1 ACCESSIBLE PATH REFERENCE PLAN Show a parallelapproach clear space at the cashwrapstation. 1 C 1.2 N.I.S. The boulder isobstructing youraccessible route in this location, please revise. LEVEL 10' - 0" C A1 A50.02 LEVEL 10' - 0" LEVEL 10' - 0" 2A2A51.01 S H E E T N U M B E RP R O J E C T N U M B E R ASPENSTAMPSINTERIOR ELEVATIONS A80.03HRC010 535 E. HYMAN AVE, UNIT 108ASPEN, CO 81611 FORTY FIVE TEN ASPEN 1/2" = 1'-0"1 FITTING ROOM - EAST ELEVATION 1/2" = 1'-0"2 FITTING ROOM - NORTH ELEVATION 1/2" = 1'-0"3 FITTING ROOM - SOUTH ELEVATION 0'1'2'4'PROJECTNORTH REV. DATE ISSUE TITLEA 06.19.18 100% DD SETB 06.22.18 PERMIT SET The accessible fitting room bench should beshown in the interior elevation to demonstrateproper seat and back support height per 2009ANSI section 903. If any coat racks or hooksare proposed then at least one of each typeshall be provided within an accessible reachrange per ANSI 803.5. It should also bedimensioned in plan view where shownelsewhere to show compliance with the sizingrequirements of ANSI 903. D D A90.02 A2 A R 0' - 1" 1/4" R 0' - 1"7' - 0"3' - 9"0' - 6"LEVEL 10' - 0" B3 A90.02 LEVEL 10' - 0" LEVEL 10' - 0" 2' - 6" LEVEL 10' - 0" 1" = 1'-0"A1 CASHWRAP - PLAN 1" = 1'-0"A2 CASH WRAP - WEST ELEVATION 1" = 1'-0"B2CASHWRAP - NORTH ELEVATION 0' Dimension the heightof the cashwrapstation on theelevations to show compliance with ANSI904. A00.05 - 5G Comments -THE PARALLEL APPROACH ACCESS HAS BEEN ADDED TO THE PLANS. A00.05 - 5G Comments -THE SIZE OF THE ROCK HAS BEEN MODIFIED TO ACCOMODATE THE ACCESSIBLE PATH. -DIMENSIONS HAVE BEEN ADDED TO CLARIFY THE REQUIRED ACCESSIBLE WIDTH. A80.03 - 5G Comments -THE MIRROR AND HANGING ROD WALLS WERE SWITCHED. THIS DETAIL IS NOW SHOWN ON 2/A80.03. -THE DIMENSION CONSTRAINTS AND REQUIRED CONNECTION FOR BACK SUPPORT ARE NOTED. -THE HEIGHT OF THE COAT RACK IS ALSO NOTED ON 2/A80.03 A90.02 - 5G Comments -DIMENSIONS HAVE BEEN ADDED TO SHOW THE TOP OF COUNTER AT 2'-10" AFF. 08/14/2018 Subject: PlanCheck Page Label: E20.01 Floor Plan - Electrical Author: justinh File Name: PlanSet.535 E Hyman Unit 108.2018.06.pdf The lighting plan must show compliant lighting controls per IECC C405.2.1-405.2.5, this will include either time switch controls (C405.2.2) or occupant sensors (C405.2.1) throughout the space as well as manual light reduction controls (C405.2.2.2). Provide cutsheets for all light fixtures that provide maximum fixture wattage as well as NRTL listing. DDD JDJD 1 C 1.2 B A-1 A-12 4 1 C 21.2 B 2.3 L1A-5c A-10 A1 2 EMA-5 EMA-5 EMA-5 EMA-5 X A-7VIA LTGCONTACTOR A-9VIA LTGCONTACTOR L1A-5c L1A-5c L1A-5c L1A-5b L1A-5b L1A-5b L1A-5bL1A-5b L1A-5b L1A-5a L1A-5b L1A-5a L1A-5a L1A-5b L1A-5b L1A-5bL1A-5bL1A-5b L1A-5b L1A-5bL1A-5b L1A-5b L1A-5b L1A-5a L1A-5a L1A-5a L1A-5b L1A-5b L1A-5b L1A-5b L1A-5b L1A-5b L1A-5bL1A-5bL1A-5b L1A-5b L1A-5b L1A-5b L1A-5a L1A-5a L1A-5bL1A-5aL1A-5a L1A-5b L1A-5b L1A-5b L1A-5b L1A-5b L1A-5b L1A-5bL1A-5b L2 L2 L3 1/4" = 1'-0"1 Floor Plan - Power 1/4" = 1'-0"2 Reflected Ceiling Plan - Lighting 3 ALL MOUNTING HEIGHTS SHALL BE CONFIRMED WITH ARCHITECT PRIOR TO ROUGH-IN.4 CONTRACTOR SHALL VERIFY DIMMING METHODS FOR DIMMED FIXTURES WITH DIMMERSWITCHES/CONTROLS BEFORE PURCHASE.5 EMERGENCY FIXTURES AND EXIT SIGNS SHALL BE CONNECTED TO THE LOCAL LIGHTINGCIRCUIT AHEAD OF ALL CONTACTORS AND SWITCHING. The lighting plan must show compliantlighting controls per IECCC405.2.1-405.2.5, this will include eithertime switch controls (C405.2.2) oroccupant sensors (C405.2.1) throughoutthe space as well as manual light reductioncontrols (C405.2.2.2). Provide cutsheetsfor all light fixtures that provide maximumfixture wattage as well as NRTL listing. A90.02 - 5G Comments -THE RCP HAS BEEN UPDATED TO REFLECT VE DESIGN CHANGES. -THE LIGHTING CONTROLS ARE NOTED UNDER THE KEYNOTES "1." -REFER TO "Light.535 E Hyman unit 108.2018.08.pdf" FOR LIGHT FIXTURE CUTSHEETS. -A10.02 WAS UPDATED TO REFLECT THE REVISED LIGHTING AND REVISED CIRCUT. GENERAL NOTES: -ADDITIONAL DRAWINGS ARE INCLUDED IN THE COMMENT RESPONSE BECAUSE OF RELATED CHANGES TO THE COMMENTS ABOVE. -THE FLOOR ASSEMBLY HAS CHANGED FROM METAL STUD, PLYWOOD, AND TILE TO CONCRETE OVER STRUCTRUAL FOAM. PAUL MERRILL PRINCIPAL 5G STUDIO COLLABORATIVE 214.347.7564 08/14/2018