Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.535 E Hyman Ave.0080.2018 (8).ACBK
page 1 of 2 www.luminii.com tel: 224-333-6033REV2.4 05102018 Easy-Link Line Voltage Linear Illumination System EL MODEL Ordering code 27K - 2700 K30K - 3000 K35K - 3500 K 12 - 11.5” 24 - 23.75” 36 - 35.5” 48 - 47.25” EL - Easy-Link D D - Dimming (Triac) LENGTH DIMMINGCCT 120V 120V - 120VAC VOLTAGE Finish options White powder coated Technical information Extruded aluminum line voltage linear illumination system, Easy-link features specifically designed 120V AC LED engine that provides constant illumination levels from the beginning to the end of the runs. Easy-link is suitable for cove lighting, architectural accents, under or above cabinets and many other applications. Available in sections of 12”, 24”, 36” & 48” long with the option to extend up to 10 fixtures joined together. 12”, 24”, 36” or 48” 1.20” 0.96”1.07” with mounting clip Output Options (3000K) Lumens 318 lum/ft CRI 90+ Operating Voltage 120 VAC Power Consumption Section Length Wattage 12”3.8 W 24”8.3 W 36”11.5 W 48”15 W CCT/Lumen multiplier Color temperature Multiplier (Multiple Light Output of 3000K HO) CRI 2700 K 0.81 98 3000 K 1.00 91 3500 K 0.98 95 35K24/36 L1/L2 535 E HYMAN, UNIT 108, ASPEN 08/14/2018 page 2 of 2 www.luminii.com tel: 224-333-6033REV2.4 05102018 Easy-Link Line Voltage Linear Illumination System Accessories (sold separately) Sample Layout Joiner (1 per fixture) 12” Easy-Link Cord to 120V ACsensor/switchjumper cableup to 10 Easy-link joined together jumper cable Part # JC-6 (5.9”long) Part # JC-12 (11.8”long) Part # JC-24 (23.6”long) joiner 1 provided per fixture power cord Part # PC-72 (72” long) occupancy sensor/switch (splice box) Part # EL-OSSB-WH occupancy sensor/switch (used with power cord accessory) Part # EL-OSSB-PC-WH • Provides excellent detection of large motion (walking) when mounted between 15 to 40 ft. •15 to 20 ft radial coverage overlaps area lit by a typical high bay fixture. • Recommended for fixtures that have a 1:1 spacing to mounting height ratio or less (e.g.,fixtures 30’ on center or less @ a 30’ mounting height). on/off switch (splice box) Part # EL-SB-WH on/off switch (used with power cord accessory) Part # EL-SB-PC-WH length 0.45” 2.32” 2.32” 4.35” 4.35” 1.49” 1.85” EL-OSSB-XX EL-SB-XX 72.00” 08/14/2018 2016.V02 iQ LED TAPE LIGHT 5050 CHIP SERIES iQ20 2.6 W/ft : DRY RATED NOTE: Q-Tran offers multiple LED Chip offerings based upon size and pitch,each utilizing its own binning. Utilization of multiple outputs within the same chip family will ensure flawless color matching and similar overall diffusion. iQA-LATO iQA-FLUR COMPATIBLE EXTRUSIONS 15° 50° 60° 80° 90°iQA-VEGA BEAM ANGLESBEAM ANGLES BEAM ANGLES iQA-WIDE iQA-SQUR iQA-RONDiQA-45DW-RDiQA-SLIM iQA-45DW-90 60°80°125°45° 100°128°iQA-VEVE BEAM ANGLES COMPATIBLE POWER SUPPLIES Interior Applications • QJB & QJBL • Q6M-DC & DC+CAP • QTM-eLED, QTM-DC & DC+CAP • iQ-PH 125°100°FEATURES • LED life time - 40,000 hours • Operating temperature: -4ºF ~ +113ºF • Suitable for dry location • Non-Ferrous Material • 6.57" cut points • Field cuttable • 3 year warranty © 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com 1 PROJECT NAME DATE TYPE NOTECOMPANY DIMENSIONS 1.09" 6.57" Cut Length LED Seperation .39" .09" .39" .09" NOTE: Cut marks of LED tape allows for changes in the field. COMPLIANT 2.6 watts per foot= cut every 6.57" Lead wire comes standard on all LEDs in 18" (18/2 AWG) iQ20 90 2.650 iQ Series Color Temp Chip CRI Watts Per FT Length ---- iQ20 LED Flexible Tape Light is available in 2500K, 2700K, 3000K, 3500K, and 4000K. This easy to install, flexible product is suitable for indoor, dry locations and can be cut to specification at Q-Tran or in the field. This specific iQ20 LED Flexible Tape Light is available in 2.6 watts per foot with a Chip 5050, is 24VDC, and has a CRI of over 90. It is ideal for cove lighting, cabinet lighting, office shelves, wine racks, accents, toekicks, retail displays and more. LEAD WIRE iQ20-25-50-90-2.6 Max Run / Reel Length: 35ft* | ColorTemp: 2500K | Voltage: 24VDC CRI: 90+ | LM: 79 | Watts Per Ft: 2.6 | Lumens Per Ft: 123 iQ20-27-50-90-2.6 Max Run / Reel Length: 35ft* | ColorTemp: 2700K | Voltage: 24VDC CRI: 90+ | LM: 79 | Watts Per Ft: 2.6 | Lumens Per Ft: 148 iQ20-30-50-90-2.6 Max Run / Reel Length: 35ft* | ColorTemp: 3000K | Voltage: 24VDC CRI: 90+ | LM: 79 | Watts Per Ft: 2.6 | Lumens Per Ft: 222 iQ20-35-50-90-2.6 Max Run / Reel Length: 35ft* | ColorTemp: 3500K | Voltage: 24VDC CRI: 90+ | LM: 79 | Watts Per Ft: 2.6 | Lumens Per Ft: 219 iQ20-40-50-90-2.6 Max Run / Reel Length: 35ft* | ColorTemp: 4000K | Voltage: 24VDC CRI: 90+ | LM: 79 | Watts Per Ft: 2.6 | Lumens Per Ft: 230 *Maximum length for one run of iQ20 LED 2.6. Individual Power supply cut sheets will provide max distance/loads per power supply. 35 xx 535 E HYMAN, UNIT 108, ASPEN L3 08/14/2018 © 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com 2 0 15 30 45 60 7590105 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 345 520 560 540 580 600 620 700 500 490 480 470460 380 x y 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.00.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8150001200010000900080007000600050004000300020000 400 450 500 550 600 650 700 750 800 0 15 30 45 60 7590105 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 345 520 560 540 580 600 620 700 500 490 480 470460 380 x y 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.00.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8150001200010000900080007000600050004000300020000 400 450 500 550 600 650 700 750 800 50.6% iQ20 2.6 W/ftiQLEDPHOTOMETRIC Light efficiency: Light quality: Color temperature: 2469 K 115.1° (2 C-PLANES) iQ20-25-50-90-2.6 COLOR PARAMETERS BEAM DETAILS CCT CRI CRI R9 TM30 Rf TM30 Rg CQS x y u v Duv 86.3 CIE 1931 75.1% Electrical Test Condition for1foot Output:123 lm/ft Peak:40.7 cd Power:2.6 W/ft 24V @ 0.108A CIE1931 Color Color 2469 K CRI :91.1 Beam angle 50% Field angle 10% Cutoff angle 2.5% Intensity ratio in 120°cone Intensity ratio in 90°cone Spectra 115.1°163.8°220.7° 2469 K 91.1 59.4 0.0019103.8 81.1 0.5 3.04.0 4.0 3.04.0 4.05.0 x:0.476y:0.408 x:0.476 y:0.408 47 Lumen/Watt 50.6% Light efficiency: Light quality: Color temperature: 2709 K 115.7° (2 C-PLANES) iQ20-27-50-90-2.6 COLOR PARAMETERS BEAM DETAILS CCT CRI CRI R9 TM30 Rf TM30 Rg CQS x y u v Duv 89.9 CIE 1931 75.1% Electrical Test Condition for1foot Output :148 lm/ft Peak:48.6 cd Power:2.6 W/ft 24V @ 0.108A CIE1931 2709 K CRI :91 Beam angle 50% Field angle 10% Cutoff angle 2.5% Intensity ratio in 120°cone Intensity ratio in 90°cone Spectra 115.7°164.3°220.7° 2709 K 91 56.4 0.003399.4 79.1 x:0.465y:0.421 x:0.465 y:0.421 57 Lumen/Watt 08/14/2018 0 15 30 45 60 7590105 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 345 520 560 540 580 600 620 700 500 490 480 470460 380 x y 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.00.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8150001200010000900080007000600050004000300020000 400 450 500 550 600 650 700 750 800 0 15 30 45 60 7590105 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 345 520 560 540 580 600 620 700 500 490 480 470460 380 x y 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.00.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8150001200010000900080007000600050004000300020000 400 450 500 550 600 650 700 750 800 51.6% iQ20 2.6 W/ftiQLEDPHOTOMETRIC Light efficiency: Light quality: Color temperature: 3142 K 115.7° (2 C-PLANES) iQ20-30-50-90-2.6 COLOR PARAMETERS BEAM DETAILS CCT CRI CRI R9 TM30 Rf TM30 Rg CQS x y u v Duv 89.1 CIE 1931 76.5% Electrical Test Condition for1foot Output:222 lm/ft Peak:74 cd Power:2.6 W/ft 24V @ 0.108A CIE1931 Color Color 3142 K CRI :91.2 Beam angle 50% Field angle 10% Cutoff angle 2.5% Intensity ratio in 120°cone Intensity ratio in 90°cone Spectra 115.7°163.6°174.3° 3142 K 91.2 62.3 0.0013100.1 89.0 0.4 2.04.0 3.0 2.04.0 3.04.0 x:0.429y:0.405 x:0.429 y:0.405 86 Lumen/Watt 51.4% Light efficiency: Light quality: Color temperature: 3667 K 115.6° (2 C-PLANES) iQ20-35-50-90-2.6 COLOR PARAMETERS BEAM DETAILS CCT CRI CRI R9 TM30 Rf TM30 Rg CQS x y u v Duv 89.9 CIE 1931 76.2% Electrical Test Condition for1foot Output :219 lm/ft Peak:72.6 cd Power:2.6 W/ft 24V @ 0.108A CIE1931 3667 K CRI :95 Beam angle 50% Field angle 10% Cutoff angle 2.5% Intensity ratio in 120°cone Intensity ratio in 90°cone Spectra 115.6°163.2°210.1° 3667 K 95 81.2 0.0023100.3 90.3 x:0.394y:0.38 x:0.394 y:0.38 84 Lumen/Watt © 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com 3 08/14/2018 © 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com 4 iQ LED TAPE LIGHTCOMPATIBLE POWER SUPPLIES Electronic 0-10V Dimming QTM Electronic Driver Non-Dimming QTM GND HOT NEU +- SECONDARY PRIMARY PURPLE GREY 0-10VDIMMING 0-10V DIMMABLE POWER SUPPLY iQ-LED LED Tape Light : Wire lead can be trimmed to lengthas needed #0674 FT. Q-TRAN RIP STRIPTM P/N 988182M _ Positive Negative + +- SECONDARY PRIMARY iQ-LED LED Tape Light : Wire lead can be trimmed to lengthas needed #0674 FT. Q-TRAN RIP STRIPTM P/N 988182M _ Positive Negative + GND HOT NEU 08/14/2018 © 2016, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com 5 iQ LED TAPE LIGHTCOMPATIBLE POWER SUPPLIES Magnetic with DimmerDCor DC+CAP Magnetic without DimmerDCor DC+CAP QT & Q6 iQ-PH-80 QT & Q6 iQ-LED GND HOT NEU + - SECONDARY PRIMARY iQ-LED DIMMER WITH NEUTRAL FORWARDPHASE MLV GND HOT HOT NEU + - SECONDARY PRIMARY iQ-LED GND HOT NEU + - SECONDARY PRIMARY #0674 FT. Q-TRAN RIP STRIPTM P/N 988182M _ Positive Negative + iQ-LED Tape Light : Wire lead can be trimmed to length as needed #0674 FT. Q-TRAN RIP STRIPTM P/N 988182M _ Positive Negative + iQ-LED Tape Light : Wire lead can be trimmed to length as needed #0674 FT. Q-TRAN RIP STRIPTM P/N 988182M _ Positive Negative + iQ-LED Tape Light : Wire lead can be trimmed to length as needed Phase Controlled Dimming 08/14/2018 Fixture Type: Catalog Number: Project: Location: WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Avenue • Ontario, CA 91760 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Sep 2014 PRODUCT DESCRIPTION Designed for nearly every application and interior environment, our extensive 120V Track collection offers hundres of luminaires that integrate cutting edge design and aerospace detailing with designer glass and metal finishes. Versatile yet sturdy, the track systems can be surface mounted or suspended from the ceiling, liberating luminaires from the constraints of rigid mountings and enabling the lighting design to adapt to changing styles and spaces. FEATURES • May be field cut and easily installed on a variety of surfaces • Available extension accessories • Use compatible Quick Connect™ pendants and fixtures with each system • End caps and mounting hardware included • Retrofits into many popluar track systems on the market today. SPECIFICATIONS Materials: Aluminum extrusion with copper bus wire. Electrical: 20 Amps rated, 120V. It is common practice to use tracks at 80% capacity to insure compatibility with dimmers and connectors (1920W maximum). Mounting: Can be installed on drywall, or suspended ceilings. Standards: UL & CUL listed – Example: HT6-DB ORDER NUMBER Model Length Finish HT H Track 2 4 6 8 2' 4' 6' 8' BK BN WT DB Black Brushed Nickel White Dark Bronze each section includes two matching end caps. H TRACK 120V Single Circuit Track System 1a" n" b"Neutral Ground Circuit Selecting Connectors (example using H Track) = Electrical Continuity Polarity is just a matter of matching ends The 2 wire side of an "H" Track has an indicator groove running its length • Using a left connector, the track would run with the groove along the outside • Using a right connector, the track would run with the groove along the inside L LR L L L L Left Connector (HL–LEFT) • Groove on the Outside Edge • Contacts on the Outer Angle R R R R • Groove on the Inside Edge • Contacts on the Inner Angle Right Connector (HL–RIGHT) • In order to select the appropriate connectors to maintain electrical continuity, start at your power source and walk the length of the track. If you turn left, use a left connector. If you turn right, use a right connector. Sample Layout A SK18 18" Track suspension rod B HLE Live end connector C HT2 2 foot Section of H Track D HL–LEFT "H" Connector (Left) E H–LED17S-27 LeDme™ LeD track head F H–ENDCAP end Cap (included with track section) A B C C E F D L-T2, L-T4, L-T6 FFT ASPEN 535 E HYMAN, UNIT 108, ASPEN HT2,4,6 BK 08/14/2018 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Sep 2014 Accessories Model Finish Description Live end Connector HLE BK BN WT DB 44” × 1 a” × w” Use for direct wiring through ceiling. A canopy plate is required when using with a standard junction box. Live end BX Connector HBXLE BK BN WT DB 6” × 1a” ×1 4” Use with surface mounted BX or non-metallic sheathed cable. Also provides through the ceiling connection. "I" power Connector HI- PWR BK BN WT DB 6w” × 1a” × w”power entry point at the connection of 2 tracks. "L" Connector Left HL- LEFT BK BN WT DB 2w” × 2w” × w” Use to join 2 track sections to make power feedable 90° left polarity turns."L" Connector Right HL- RIGHT "T" Connector HT BK BN WT DB 4” × 2w” × w” Use to join 3 track sections. power feedable on H and J only. "T" Connector with opposite polarity can be custom ordered. "X" Connector HX BK BN WT DB 48” × 48” × w” Use to join 4 track sections. power feedable on H and J only. "I" Connector HI BK BN WT DB 3” × 1a” × w” Use to join two sections of track with electrical continuity. "I" Dead end Connector HI-DEC BK BN WT DB 3” × 1a” × w”Joins two sections of track without electrical continuity. Flexible Track Connector HFLX BK BN WT DB 11” × 1a” × w” Connects two track sections at variable angles. Use as a transition from wall-to-wall, wall-to-ceiling, or ceiling-to- ceiling. power feedable. Suspension Loop H- LOOP BK BN WT DB 1a” × 1a” × 3” 3 inch electrical loop accepts chain hung fixtures up to 35lbs. Contains compartment for electrical connections. 15’ Cord, Male plug HCORD BK WT 15'Maximum capacity: 7A, 800W, 120V. T-Bar Drop Ceiling Attach T-BARCLIP 12” × 14” Attaches track to T-bar drop ceilings. Use two for 2 foot or 4 foot tracks, three for 6 foot or 8 foot tracks. Canopy plate CP BK BN WT DB 42” × 42”Covers a standard 4 inch junction box. Use with any powerable connectors. Floating Canopy Connector HFC BK BN WT DB 42” × 42” × 12” Connects to octagon box. Allows track to be powered anywhere along the length of the track. Adapters Model Finish Description Quick Connect™ Adapter EN-HQ50AR BK BN WT DB Connects pendant or fixture to track. Monopoint Canopy Adapter HMP Ø 4w” BK BN WT DB Mount a single H, L or J system track fixture to a junction box. When used with a low voltage track head the transformer box will protrude off of the face of the monopoint. Track Suspension Model Finish Description All Track Suspension Kit SK 18 24 36 48 18" 24" 36" 48" BK BN WT DB extends track from ceiling. Includes track bracket, rod and ceiling canopy. Suspension Kit extender R 18 24 36 48 72 18" 24" 36" 48" 72" BK BN WT DB Use with Rod Coupler (RI) to further extend track from ceiling. Sloped Ceiling Adapter SK14 BK BN WT DB Use with suspension kits for sloped ceilings Rod Coupler RI BK BN WT DB Join two rods for suspensions longer than 48". Suspension Adjustment Collar kit SK05 BK BN WT DB Used when suspension rod is field cut to custom lengths. One kit of two required for each rod. Low Voltage Track Head extension X 6 12 18 24 36 48 6" 12" 18" 24" 36" 48" BK BN WT DB extends low voltage track heads from track. Only available as complete unit. Line Voltage Track Head extension H 18 24 36 48 18" 24" 36" 48" BK BN WT DB extends H System line voltage track heads. Wall Mount Suspension Bracket TBKT 18" BK BN WT DB extends track 24" from wall. Use two per 4’ length, three per 8’ length. H TRACK 120V Single Circuit Track System 08/14/2018 Fixture Type: Catalog Number: Project: Location: WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Avenue • Ontario, CA 91760 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Sep 2014 H TRACK CURRENT LIMITER 120V Track System Model H Track Circuit Breaker Max Wattage Finishes Dimensions Single Live end THL-HLE-1A 1 × 1A 1 × 120W BK BN DB WT Black Brushed Nickel Dark Bronze White 72” × 5” × 14” THL-HLE-2A 1 × 2.5A 1 × 300W THL-HLE-5A 1 × 5A 1 × 600W THL-HLE-7A 1 × 7.5A 1 × 900W THL-HLE-10A 1 × 10A 1 × 1200W Double Live end THL-HI-1-1A THL-HI-2-1A 1 × 1A 2 × 1A 1 × 120W 2 × 120W THL-HI-1-2A THL-HI-2-2A 1 × 2.5A 2 × 2.5A 1 × 300W 2 × 300W THL-HI-1-5A THL-HI-2-5A 1 × 5A 2 × 5A 1 × 600W 2 × 600W THL-HI-1-7A THL-HI-2-7A 1 × 7.5A 2 × 7.5A 1 × 900W 2 × 900W THL-HI-1-10A THL-HI-2-10A 1 × 10A 2 × 10A 1 × 1200W 2 × 1200W Double Live end (Left) THL-LEFT-1-1A THL-LEFT-2-1A 1 × 1A 2 × 1A 1 × 120W 2 × 120W THL-LEFT-1-2A THL-LEFT-2-2A 1 × 2.5A 2 × 2.5A 1 × 300W 2 × 300W THL-LEFT-1-5A THL-LEFT-2-5A 1 × 5A 2 × 5A 1 × 600W 2 × 600W THL-LEFT-1-7A THL-LEFT-2-7A 1 × 7.5A 2 × 7.5A 1 × 900W 2 × 900W THL-LEFT-1-10A THL-LEFT-2-10A 1 × 10A 2 × 10A 1 × 1200W 2 × 1200W Double Live end (Right) THL-RIGHT-1-1A THL-RIGHT-2-1A 1 × 1A 2 × 1A 1 × 120W 2 × 120W THL-RIGHT-1-2A THL-RIGHT-2-2A 1 × 2.5A 2 × 2.5A 1 × 300W 2 × 300W THL-RIGHT-1-5A THL-RIGHT-2-5A 1 × 5A 2 × 5A 1 × 600W 2 × 600W THL-RIGHT-1-7A THL-RIGHT-2-7A 1 × 7.5A 2 × 7.5A 1 × 900W 2 × 900W THL-RIGHT-1-10A THL-RIGHT-2-10A 1 × 10A 2 × 10A 1 × 1200W 2 × 1200W Example: THL-LEFT-1-1A-WT Low Cost Energy Code Compliance Made Easy • Easy to install and assures compliance to California Title 24 or ASHRAE 90.1 requirements • Energy code track installations are subject to wattage limitations based upon the size and usage of the space • To order appropriate current limiter, select the model number which corresponds to the H system to the maximum allowable wattage • May be mounted as a standard canopy, used in place of an “I” connector or as a live-end How It Works • If the track is overloaded the current limiter circuit breaker will trip and shut down power to the track. • May be reset when the overall sum of fixture wattages are reduced. below the circuit breaker rating • It’s that easy to ensure energy efficient usage of track installations. THL–HLe–1A Output 1 × 120W 1A × 120V = 120W max load carrying capacity H-LED820 21W H-LED820 21W H-LED820 21W H-LED820 21W H-LED820 21W H-LED820 21W ≤ 120W = 126W > 120W++++ 08/14/2018 Passion. Power. Performance. Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 1 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance.SPEQ Cylinder Track HeadsFeatures Designed to let the interior design and not the lighting take center stage, the SPEQ track head from Amerlux balances clean, minimal aesthetic design with industry leading optical performance. The fi xture has no visible heat sink or venting and has snoot perfectly matched to provide excellent glare control while maintaining the clean fi xture lines. The integral driver is fully featured with low end dimming and full 2.5 KV surge protection (not a lamp driver!) Perfect for Galleries, Retail and Commercial interiors SPEQ uses high end optical designs to ensure your space is lit perfectly and effi ciently. PROJECT: TYPE: 55 Electrical Data 9W 15W 18W 21W System Watts Amps System Watts Amps System Watts Amps System Watts Amps 120V 9 0.08 15 0.13 18 0.15 21.4 0.18 277V N/A N/A N/A N/A N/A N/A 21.8 0.08 26W 33W 41W 48W System Watts Amps System Watts Amps System Watts Amps System Watts Amps 120V 26 0.22 33 0.28 41 0.34 48 0.40 277V 26 0.09 33 0.12 41 0.15 48 0.17 Electronic constant current LED driver SPEQ Cylinder Track Heads Product Overview Type: Track Accent & Display SM MD LG Wattage (max): 15W 26W 48W Lumen Output: 1,310 2,056 3,977 LPW: 89.5 78.4 82.8 CBCP: 9,393 14,898 46,856 Color Temp: 2200K, 2700K, 3000K, 3500K, 4000K CRI: 83 typ. & 90+ typ. CrispWhite & 3K Class A LED's available Dimming: TRIAC & ELV (120V/277V) - 5% Dim Watts Delivered Lumens LPW CBCP Color Temp 9 812 91 5,824 3000K-83 15 1,310 89.5 9,393 3000K-83 18* 1,215 68.6 26,813 3000K-83 21 1,850 88 13,578 3000K-83 26 2,056 78.4 14,898 3000K-83 33 2,903 88.2 34,204 3000K-83 41 3,460 84.4 40,764 3000K-83 48 3,977 82.8 46,856 3000K-83 Performance Chart Fixture Summary (see following pages for more information)SmallMediumLargeSmall Medium Large Availability: 7/21/17 SPEQ-M/SPEQ-L 9/8/17 SPEQ-S Data is based on Spot optic, except for 18W. *18W is VNSP only. 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 2 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads Model SPEQ-S-A17† (small) SPEQ-M-A17† (medium) SPEQ-L-A17† (large) Wattage SM MD LG 9 18 33 15 21 41 26 48 Finish WT - white texture BT - black texture ST - silver texture Other fi nishes, consult factory Mounting TN1 - Global 1cir/H-Style, 120V TEK - Global 2cir/2neut, 120V TN3 - Global 3cir, 120V TN2 - Global 2cir/2neut, 277V CT - J-Style, 120V LOL - L-Style, 120V B* - busway, 120V/277V C - canopy, 120V/277V CCL2-SCP - C-clamp, black, with straight cord**, 6’ CCL2-CCP - C-clamp, black, with coil cord**, 5’ Notes: *Black busway adapter used for ST fi nish **Black cord used for BT & ST fi nish, White cord used for WT fi nish Voltage 120 277 (not available on SPEQ-S and SPEQ-M (18W only)) Beam Spreads SM MD LG SP - spot 15° VNSP - very SP - spot 15° NF - narrow fl ood 22° narrow spot 8° FL - fl ood 25° MFL - med fl ood 25° (18W only) WF - wide FL - fl ood 28° SP - spot 15° fl ood 36° WF wide fl ood 45° VNF - very VWF - very wide narrow fl ood 18° fl ood 60° NF - narrow LS - linear spread fl ood 23° 60° x 10° FL - fl ood 34° WF - wide fl ood 44° Color Temp 83 CRI: 90+ CRI: 27 - 2700K-83 229†† - 2200K-90+ CRISP - CrispWhite 30 - 3000K-83 279 - 2700K-90+ 3CLA - 3K Class A 35 - 3500K-83 309 - 3000K-90+ 40 - 4000K-83 359 - 3500K-90+ 409 - 4000K-90+ ††Note: available for SPEQ-S & SPEQ-M only Driver LE/TE - TRIAC/ELV dimming SPEQ-S/M (18W): 120V only SPEQ-M (21W/26W)/SPEQ-L: 120V/277V Options/Accessories SN - snoot HEX - hexcell louver SOL - solite beam softening lens LS - linear spread lens CB - cross blade (requires snoot) † The "A" refers to the sequential revision in a year and "xx" refers to the year of update. Updates coincide with improved performance while not changing the overall fi xture aesthetic and are refl ected in the published performance data. Please contact your Amerlux representative for explanations of changes. 1 2 3 4 5 6 7 8 8 9 Ordering Information 1 2 3 4 5 6 7 9 Availability: 7/21/17 SPEQ-M/SPEQ-L 9/8/17 SPEQ-S L-5535 E HYMAN, UNIT 108, ASPEN SPEQ-S-A17 15 BT TN1 120 WF 309 LE/TE SN-SOL 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 3 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsSpecifi cations Application Retail, Museum, Gallery, Hospitality and Commercial accent and display lighting Construction Complete die-cast aluminum construction No exposed wiring Unique magnetic dual lock front door Tilt indicating marks for common tilt positioning SPEQ-M and SPEQ-L feature tilt locking mechanism Optical 0-90º tilt, 360º rotation (tilt lock on Medium & Large) Small uses an Amerlux Designed TIR optical system Medium use a Patented Amerlux designed TIR optical system. Large uses an Amerlux designed Refl ector optical system. Beam Spreads vary by fi xture size. Please see Specifi cation on Page 2. LED Colo r Temp Options: 2200K†††, 2700K, 3000K, 3500K, 4000K, CRISP, Class A CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) 90+ typ. (2200K†††, 2700K, 3000K, 3500K) CrispWhite* and Class A** LEDs available R9 Values: 11 (83 CRI), 55 (90+ CRI) Binning: 3 MacAdam (SDCM) Life: 50,000+ hrs, > 70% of initial lumens at 50,000 hrs *CrispWhite: CrispWhite Technology delivers the warmth of colors expected from a high 90 CRI solution but also creates the natural crisp white color similar to CMH sources. It creates impactful lighting by revealing the richest whites and vibrant colors that pop. **Class A LED: Class A LED’s have a CRI > 80 and a GAI > 80. CRI defi nes color “Naturalness” and GAI defi nes color “Saturation.” Both being high delivers rich colors and pure whites. †††Available on SPEQ-S and SPEQ-M only Electrical Wattage: SM: 9, 15 MD: 18, 21, 26 LG: 33, 41, 48 Electronic constant current LED driver, 120V/277V input This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Amerlux® recommends using additional surge protection with this unit (supplied by others), surge damage is not covered under warranty. Driver LE/TE - Leading Edge (Triac, Forward Phase) or Trailing Edge (ELV, Reverse Phase) autosensing driver dims down to less than 5% on most dimming system. Note: 120V only on SPEQ-S and SPEQ-M (18W); 120V/277V on SPEQ-M (21W/26W) and SPEQ-L See dimming pages for more information. Finish Powder coat paint. Standard colors: White Texture, Black Texture, Silver Texture Consult factory for custom RAL powder coat fi nishes Mounting Track, canopy, c-clamp and busway. Note: Ceiling mounted track only Certifi cations Approved to UL standards as tested by CSA. Intended for indoor use only. Warranty 5 year limited warranty 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 4 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads6 15/16”1 1/16”7 3/8”9 1/2”6 1/2”Ø3 7/8” Ø5 1/8” 4 15/16”3 1/8”4”5”4 3/4” 3 5/16”5 9/16”6 1/4”4 5/16”1”2 7/16”5 15/16”Ø2 3/4” Ø1 5/8” SPEQ-S SPEQ-M SPEQ-L 3 5/16”8 7/8”6 3/16” 6 1/4”1 1/8”Shown with TN1 adapter Shown with TN1 adapter Shown with TN1 adapter 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 5 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsSPEQ-S SNOOT & ACCESSORIES SPEQ-M SNOOT & ACCESSORIES SPEQ-L SNOOT & ACCESSORIES Clear Lens Linear Spread Lens Linear Spread Lens Linear Spread Lens Solite Lens Solite Lens Clear Lens Hexcell Louver Hexcell Louver Front Door Front Door Snoot Snoot Solite Lens Prismatic Lens Hexcell Louver Snoot Front Door Snoot Cross Blade (requires snoot) Cross Blade (requires snoot) 3 5/16”Ø1 5/8” 1 5/16”5 15/16”5”9”1 3/4” 2 3/8”8 7/8”5 9/16”4 5/16”7 3/8”Ø2 3/4” Cross Blade (requires snoot) Ø3 7/8” Ø5 1/8” 6 3/16”4 7/8”11 5/8”6 3/4”6 3/8”8 11/16”8 7/8”Snoot Snoot Shown with TN1 adapter Shown with TN1 adapter Shown with TN1 adapter 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 6 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60º Candelas at Nadir Deg Candela 0 5995 5 5113 15 1733 25 345 35 101 45 38 MEDIUM FLOODMedium Flood (MFL), 25° LTL # 11756217.03 Lumens: 1,192 Candelas at Nadir Deg Candela 0 9393 5 7082 15 1786 25 268 35 86 45 27 Spot (SP), 15° LTL # 11756217.01 Lumens: 1,310 SPOT D FC L W 5.0’ 375 1.5 1.5 7.5’ 167 2.3 2.3 10.0’ 94 3.1 3.1 12.5’ 60 3.8 3.8 D FC L W CB 5.0’ 242 2.1 1.7 3.0 7.5’ 108 3.1 2.7 4..0 10.0’ 60 4.1 3.6 6.0 12.5’ 40 5.0 4.4 7.0 D FC L W CB 5.0’ 155 2.5 2.2 3.0 7.5’ 72 3.6 3.2 4.0 10.0’ 40 4.8 4.3 5.0 12.5’ 26 6.0 5.3 7.0 D FC L W CB 5.0’ 119 2.8 2.6 3.0 7.5’ 54 4.1 3.7 4.0 10.0’ 30 5.5 5.0 5.0 12.5’ 19 7.0 6.3 6.0 D FC L W 5.0’ 272 1.7 1.7 7.5’ 116 2.8 2.8 10.0’ 64 3.6 3.6 12.5’ 41 4.6 4.6 D FC L W 5.0’ 166 2.3 2.3 7.5’ 74 3.4 3.4 10.0’ 42 4.5 4.5 12.5’ 27 5.6 5.6 D FC L W CB 3.0’ 141 3.3 1.8 5.0 4.0’ 85 4.1 2.4 6.0 5.0’ 53 5.2 3.0 8.0 6.0’ 38 6.3 3.5 9.0 D FC L W CB 3.0’ 513 1.7 1.2 2.0 4.0’ 364 1.7 1.4 2.0 5.0’ 235 2.1 1.7 3.0 6.0’ 162 2.6 2.2 3.0 D FC L W CB 3.0’ 108 3.3 1.9 4.0 4.0’ 59 4.6 2.8 6.0 5.0’ 39 5.5 3.3 7.0 6.0’ 27 6.9 4.0 8.0 D FC L W CB 3.0’ 353 1.9 1.3 2.0 4.0’ 249 1.9 1.6 2.0 5.0’ 151 2.5 2.2 3.0 6.0’ 111 3.0 2.6 3.0 D FC L W CB 3.0’ 83 3.6 2.4 4.0 4.0’ 47 4.7 3.0 5.0 5.0’ 30 6.0 3.8 6.0 6.0’ 21 7.4 4.7 8.0 D FC L W CB 3.0’ 252 2.2 1.6 2.0 4.0’ 177 2.3 2.0 2.0 5.0’ 105 3.0 2.7 3.0 6.0’ 79 3.5 3.1 3.0 Candelas at Nadir Deg Candela 0 4146 5 3736 15 1748 25 480 35 129 45 48 Narrow Flood (NF), 22° LTL # 11756217.02 Lumens: 1,204 NARROW FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) SPEQ-S (for SPEQ-M data see page 6; for SPEQ-L data see page 7) CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) Wattage: 9W 15W Factor: 0.62 1.0 0 15 30 45 60 75 90 2250 4500 6750 9000 0 15 30 45 60 75 90 1500 3000 4500 6000 0 15 30 45 60 75 90 1000 2000 3000 4000 APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 15W LED, 3000K (For FL, WF & VWF beam options see pg 7) 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 7 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60º Candelas at Nadir Deg Candela 0 1987 5 1904 15 1378 25 702 35 259 45 88 VERY WIDE FLOODVery Wide Flood (VWF), 60° LTL # 11756217.06 Lumens: 1,158 Candelas at Nadir Deg Candela 0 3558 5 3263 15 1717 25 539 35 144 45 51 Flood (FL), 28° LTL # 11756217.04 Lumens: 1,184 FLOOD D FC L W 5.0’ 143 2.5 2.5 7.5’ 64 3.6 3.6 10.0’ 36 4.9 4.9 12.5’ 23 6.1 6.1 D FC L W 5.0’ 80 3.3 3.3 7.5’ 36 5.0 5.0 10.0’ 20 6.6 6.6 12.5’ 13 8.3 8.3 D FC L W 5.0’ 32 5.4 5.4 7.5’ 14 8.1 8.1 10.0’ 8 10.9 10.9 12.5’ 5 14.1 14.1 D FC L W CB 3.0’ 73 3.6 2.6 4.0 4.0’ 43 4.8 3.3 5.0 5.0’ 28 6.1 4.0 6.0 6.0’ 19 7.5 4.9 7.0 D FC L W CB 3.0’ 219 2.3 1.7 1.0 4.0’ 154 2.5 2.3 2.0 5.0’ 92 3.3 2.9 2.0 6.0’ 69 3.7 3.4 3.0 D FC L W CB 3.0’ 55 3.8 2.9 3.0 4.0’ 31 4.9 3.8 4.0 5.0’ 20 6.3 4.9 5.0 6.0’ 14 7.6 5.8 6.0 D FC L W CB 3.0’ 154 2.4 2.1 1.0 4.0’ 88 3.3 3.0 2.0 5.0’ 58 4.0 3.6 2.0 6.0’ 40 4.9 4.5 3.0 D FC L W CB 3.0’ 40 3.4 3.5 2.0 4.0’ 22 4.6 5.0 2.0 5.0’ 15 5.5 6.0 3.0 6.0’ 10 6.8 7.4 4.0 D FC L W CB 3.0’ 73 3.2 3.4 1.0 4.0’ 43 4.2 4.3 1.0 5.0’ 28 5.3 5.4 1.0 6.0’ 19 6.3 6.7 1.0 Candelas at Nadir Deg Candela 0 792 5 783 15 735 25 629 35 440 45 231 Wide Flood (WF), 45° LTL # 11756217.05 Lumens: 1,171 WIDE FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) SPEQ-S (for SPEQ-M data see pages 8-9; for SPEQ-L data see page 10) CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) Wattage: 9W 15W Factor: 0.62 1.0 0 15 30 45 60 75 90 1000 2000 3000 0 15 30 45 60 75 90 500 1000 1500 2000 0 15 30 45 60 75 90 200 400 600 800 APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 15W LED, 3000K (For SP, NF & MFL beam options see pg 6) D FC L W CB 5.0’ 119 2.8 2.6 3.0 7.5’ 54 4.1 3.7 4.0 10.0’ 30 5.5 4.9 5.0 12.5’ 19 7.0 6.3 6.0 D FC L W CB 5.0’ 57 3.9 3.6 2.0 7.5’ 26 5.9 5.4 3.0 10.0’ 14 7.8 7.3 4.0 12.5’ 9 9.9 9.2 5.0 D FC L W CB 5.0’ 27 5.1 5.5 1.0 7.5’ 12 7.9 8.3 2.0 10.0’ 7 9.4 10.0 2.0 12.5’ 5 13.9 14.6 3.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 8 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60º Candelas at Nadir Deg Candela 0 13840 5 10980 15 2848 25 1022 35 130 45 34 NARROW FLOODNarrow Flood (NF), 23º LTL # 11756217.10 Lumens: 2,211 Candelas at Nadir Deg Candela 0 14900 5 11130 15 1618 25 675 35 263 45 117 Spot (SP), 15º LTL # 11756217.08 Lumens: 2,056 SPOT D FC L W 5.0’ 595 1.2 1.2 7.5’ 265 2.0 2.0 10.0’ 149 2.7 2.7 12.5’ 96 3.3 3.3 D FC L W 5.0’ 553 1.4 1.4 7.5’ 246 2.3 2.3 10.0’ 139 3.0 3.0 12.5’ 89 3.6 3.6 D FC L W 5.0’ 420 2.0 2.0 7.5’ 187 3.1 3.1 10.0’ 105 4.1 4.1 12.5’ 68 5.1 5.1 D FC L W CB 3.0’ 223 2.9 1.4 5.0 4.0’ 135 3.6 1.8 6.0 5.0’ 85 4.5 2.7 8.0 6.0’ 60 5.3 3.0 9.0 D FC L W CB 3.0’ 810 1.3 1.2 2.0 4.0’ 576 1.5 1.2 2.0 5.0’ 372 1.9 1.4 3.0 6.0’ 256 2.2 1.7 3.0 D FC L W CB 3.0’ 210 3.4 1.6 4.0 4.0’ 130 4.1 2.1 6.0 5.0’ 82 5.3 2.8 7.0 6.0’ 58 6.3 3.3 9.0 D FC L W CB 3.0’ 781 1.6 1.2 2.0 4.0’ 553 1.7 1.3 2.0 5.0’ 347 2.1 1.6 3.0 6.0’ 246 2.4 1.9 3.0 D FC L W CB 3.0’ 200 3.4 2.1 4.0 4.0’ 110 4.5 2.9 5.0 5.0’ 72 5.6 3.5 7.0 6.0’ 50 6.9 4.2 8.0 D FC L W CB 3.0’ 636 2.0 1.4 2.0 4.0’ 448 2.1 1.8 2.0 5.0’ 265 2.7 2.4 3.0 6.0’ 199 3.1 2.8 3.0 Candelas at Nadir Deg Candela 0 10490 5 9345 15 3601 25 574 35 115 45 38 Very Narrow Flood (VNF), 18º LTL # 11756217.09 Lumens: 2,261 VERY NARROW FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) Wattage: 21W 26W Factor: 0.80 1.0 CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) SPEQ-M (for SPEQ-S beam options see pages 6-7; for SPEQ-L beam options see page 10) 0 15 30 45 60 75 90 2500 5000 7500 10000 12500 15000 0 15 30 45 60 75 90 2500 5000 7500 10000 12500 0 15 30 45 60 75 90 2500 5000 7500 10000 APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 26W LED, 3000K (For FL & WF beam options see pg 9; For VNSP (18W only) beam option see pg 9) D FC L W CB 5.0’ 384 1.7 1.4 3.0 7.5’ 171 2.6 2.3 4.0 10.0’ 95 3.6 3.1 6.0 12.5’ 63 4.3 3.8 7.0 D FC L W CB 5.0’ 357 2.0 1.6 3.0 7.5’ 162 2.9 2.7 4.0 10.0’ 88 4.0 3.4 6.0 12.5’ 59 4.8 4.1 7.0 D FC L W CB 5.0’ 271 2.7 2.4 3.0 7.5’ 127 3.8 3.4 4.0 10.0’ 72 5.1 4.6 5.0 12.5’ 45 6.5 5.8 6.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 9 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsAPPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC 0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 30º30º60º Candelas at Nadir Deg Candela 0 4086 5 3945 15 3033 25 1207 35 373 45 129 VERY NARROW SPOT18W ONLYVery Narrow Spot (VNSP), 8º LTL # 11756217.13 Lumens: 1,215 Candelas at Nadir Deg Candela 0 5,225 5 4981 15 3308 25 1054 35 241 45 77 Flood (FL), 34° LTL # 11756217.11 Lumens: 2,113 FLOOD D FC L W 5.0’ 210 3.0 3.0 7.5’ 93 4.4 4.4 10.0’ 53 5.9 5.8 12.5’ 34 7.4 7.4 D FC L W 5.0’ 164 3.3 3.3 7.5’ 73 5.1 5.1 10.0’ 41 6.7 6.8 12.5’ 27 8.4 8.5 D FC L W 5.0’ 1065 1.0 1.0 7.5’ 475 1.1 1.1 10.0’ 267 1.4 1.4 12.5’ 171 1.8 1.8 D FC L W CB 3.0’ 140 3.3 2.7 3.0 4.0’ 78 4.5 3.4 4.0 5.0’ 50 5.5 4.3 6.0 6.0’ 35 6.7 5.1 7.0 D FC L W CB 3.0’ 448 2.2 1.6 1.0 4.0’ 264 2.7 2.5 2.0 5.0’ 167 3.3 3.0 2.0 6.0’ 112 4.0 3.8 3.0 D FC L W CB 3.0’ 120 3.2 2.7 3.0 4.0’ 68 4.4 3.6 4.0 5.0’ 44 5.4 4.7 5.0 6.0’ 30 6.6 5.5 6.0 D FC L W CB 3.0’ 332 2.3 2.0 1.0 4.0’ 182 3.2 3.0 2.0 5.0’ 122 3.9 3.5 2.0 6.0’ 84 4.7 4.5 2.0 D FC L W CB 3.0’ 437 1.5 1.0 5.0 4.0’ 220 2.4 1.1 7.0 5.0’ 149 2.7 1.2 8.0 6.0’ 104 3.3 1.6 10.0 D FC L W CB 3.0’ 1155 1.0 1.0 2.0 4.0’ 856 1.1 1.0 2.0 5.0’ 729 1.0 1.0 3.0 6.0’ 372 1.8 1.1 3.0 Candelas at Nadir Deg Candela 0 26810 5 10210 15 536 25 406 35 152 45 64 Wide Flood (WF), 44º LTL # 11756217.12 Lumens: 2,145 WIDE FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) ˜˜18W ONLY˜˜ 0 15 30 45 60 75 90 1250 2500 3750 5000 0 15 30 45 60 75 90 1000 2000 3000 4000 0 15 30 45 60 75 90 7500 15000 22500 CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) Wattage: 21W 26W Factor: 0.80 1.0 SPEQ-M (for SPEQ-S beam options see pages 6-7; for SPEQ-L beam options see page 10) 26W LED, 3000K (For SP, VNF & NF beam options see pg 8) D FC L W CB 5.0’ 148 3.5 3.2 2.0 7.5’ 66 5.2 4.9 3.0 10.0’ 37 7.0 6.5 4.0 12.5’ 24 8.8 8.1 5.0 D FC L W CB 5.0’ 121 3.8 3.5 2.0 7.5’ 54 5.6 5.4 3.0 10.0’ 30 7.6 7.3 4.0 12.5’ 20 9.6 9.2 5.0 D FC L W CB 5.0’ 764 1.0 1.0 3.0 7.5’ 289 1.8 1.3 4.0 10.0’ 177 2.1 1.6 6.0 12.5’ 116 2.4 2.2 7.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 10 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60ºNARROW FLOODWide Flood (WF), 36º LTL # 11756217.19 Lumens: 3,355 Spot (SP), 15º LTL # 11756217.17 Lumens: 3,977 SPOT D FC L W 5.0’ 1870 1.2 1.2 7.5’ 832 1.6 1.6 10.0’ 469 2.3 2.3 12.5’ 300 2.8 2.8 D FC L W 5.0’ 523 2.2 2.2 7.5’ 233 3.3 3.3 10.0’ 131 4.3 4.3 12.5’ 84 5.4 5.4 D FC L W 5.0’ 295 3.2 3.2 7.5’ 131 4.6 4.6 10.0’ 74 6.1 6.1 12.5’ 48 7.7 7.7 D FC L W CB 3.0’ 700 2.5 1.3 5.0 4.0’ 397 3.1 1.5 6.0 5.0’ 262 3.9 2.1 8.0 6.0’ 177 4.9 2.7 9.0 D FC L W CB 3.0’ 2390 1.2 1.1 2.0 4.0’ 1714 1.4 1.1 2.0 5.0’ 1167 1.5 1.2 3.0 6.0’ 763 2.1 1.4 3.0 D FC L W CB 3.0’ 251 3.8 2.3 4.0 4.0’ 142 4.9 3.0 5.0 5.0’ 89 6.3 3.8 6.0 6.0’ 64 7.8 4.5 8.0 D FC L W CB 3.0’ 784 2.2 1.5 2.0 4.0’ 552 2.2 1.9 2.0 5.0’ 330 2.9 2.6 3.0 6.0’ 246 3.4 3.0 3.0 D FC L W CB 3.0’ 184 3.9 2.9 3.0 4.0’ 104 4.9 3.9 4.0 5.0’ 67 6.4 4.9 5.0 6.0’ 47 7.7 5.6 6.0 D FC L W CB 3.0’ 532 2.4 2.1 1.0 4.0’ 323 3.0 2.9 2.0 5.0’ 206 3.8 3.5 2.0 6.0’ 144 4.6 4.1 3.0 Candelas at Nadir Deg Candela 0 7358 5 6950 15 4652 25 2491 35 339 45 23 Candelas at Nadir Deg Candela 0 13050 5 11530 15 5156 25 1877 35 161 45 36 Candelas at Nadir Deg Candela 0 46860 5 30380 15 3118 25 1514 35 94 45 19 Flood (FL), 25º LTL # 11756217.18 Lumens: 3,538 VERY NARROW FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) Wattage: 33W 41W 48W Factor: 0.73 0.87 1.0 CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. SPEQ-L (for SPEQ-S beam options see pages 6-7; for SPEQ-M beam options see pages 8-9) 0 15 30 45 60 75 90 12500 25000 37500 0 15 30 45 60 75 90 2500 5000 7500 10000 12500 0 15 30 45 60 75 90 1750 3500 5250 7000 D FC L W CB 5.0’ 1206 1.4 1.2 3.0 7.5’ 526 2.3 1.8 4.0 10.0’ 297 3.0 2.7 6.0 12.5’ 198 3.6 3.2 7.0 D FC L W CB 5.0’ 337 2.9 2.6 3.0 7.5’ 157 4.1 3.7 4.0 10.0’ 88 5.5 4.9 5.0 12.5’ 56 6.9 6.1 7.0 D FC L W CB 5.0’ 202 3.8 3.5 2.0 7.5’ 90 5.7 5.2 4.0 10.0’ 52 7.6 6.9 5.0 12.5’ 34 9.5 8.7 6.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 11 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsDIMMING COMPATIBILITY: Amerlux® Speq fi xtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming confi guration as the exact full confi guration (Dimmer, Fixture Quantity, Voltage, etc) may aff ect dimming performance. TRIAC (Forward Phase) DIMMING (Standard) Utilizes “Standard” incandescent dimmers that are in wide use in installations across the US. . Notes: • 120V or 277V* • Dims down to less than 5% light output (most cases) • Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! • Must meet dimmer Minimum Load Requirements per dimming manufacturer Lutron “Diva” Lutron “Nova-T” Lutron “Maestro” Lutron “Vareo” Lutron “Skylark” ETC “SR” Rack w/D20 Module Lutron “GP” Panel ETC “DRD” Rack w/D20 Module Lutron Grafi k Eye QS Compatible Dimmers Wall Box (Incandescent Style, Wattage as required)Central System TRIAC Wiring Diagram ELV - Electronic Low Voltage (Reverse Phase) DIMMING (Standard) Utilizes specialized “ELV” dimmers. Notes: • 120V or 277V* • Dims down to less than 5% light output (most cases) • Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! • Must meet dimmer Minimum Load Requirements per dimming manufacturer Lutron “Diva” Lutron “Nova-T” Lutron “Maestro” Leviton “Surslide” Lutron “Vareo” Lutron “Skylark” Leviton “Vizio” ETC “SR” Rack w/ELV10 Module Lutron “GP” Panel with PHPM-PA Interface ETC “DRD” Rack w/ELV10 Module Lutron Grafi k Eye QS with PHPM-PA Interface Compatible Dimmers Wall Box (ELV Style)Central System Black White Green Red Black V+ V- Driver Line Neutral TRIAC Dimming Control Neutral ELV Wiring Diagram Black White Green Red Black V+ V- Driver Line Neutral ELV Dimming Control NeutralGround Ground Ground Ground Line Line Notes: * Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. 08/14/2018 Passion. Power. Performance. Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 1 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance.SPEQ Cylinder Track HeadsFeatures Designed to let the interior design and not the lighting take center stage, the SPEQ track head from Amerlux balances clean, minimal aesthetic design with industry leading optical performance. The fi xture has no visible heat sink or venting and has snoot perfectly matched to provide excellent glare control while maintaining the clean fi xture lines. The integral driver is fully featured with low end dimming and full 2.5 KV surge protection (not a lamp driver!) Perfect for Galleries, Retail and Commercial interiors SPEQ uses high end optical designs to ensure your space is lit perfectly and effi ciently. PROJECT: TYPE: 55 Electrical Data 9W 15W 18W 21W System Watts Amps System Watts Amps System Watts Amps System Watts Amps 120V 9 0.08 15 0.13 18 0.15 21.4 0.18 277V N/A N/A N/A N/A N/A N/A 21.8 0.08 26W 33W 41W 48W System Watts Amps System Watts Amps System Watts Amps System Watts Amps 120V 26 0.22 33 0.28 41 0.34 48 0.40 277V 26 0.09 33 0.12 41 0.15 48 0.17 Electronic constant current LED driver SPEQ Cylinder Track Heads Product Overview Type: Track Accent & Display SM MD LG Wattage (max): 15W 26W 48W Lumen Output: 1,310 2,056 3,977 LPW: 89.5 78.4 82.8 CBCP: 9,393 14,898 46,856 Color Temp: 2200K, 2700K, 3000K, 3500K, 4000K CRI: 83 typ. & 90+ typ. CrispWhite & 3K Class A LED's available Dimming: TRIAC & ELV (120V/277V) - 5% Dim Watts Delivered Lumens LPW CBCP Color Temp 9 812 91 5,824 3000K-83 15 1,310 89.5 9,393 3000K-83 18* 1,215 68.6 26,813 3000K-83 21 1,850 88 13,578 3000K-83 26 2,056 78.4 14,898 3000K-83 33 2,903 88.2 34,204 3000K-83 41 3,460 84.4 40,764 3000K-83 48 3,977 82.8 46,856 3000K-83 Performance Chart Fixture Summary (see following pages for more information)SmallMediumLargeSmall Medium Large Availability: 7/21/17 SPEQ-M/SPEQ-L 9/8/17 SPEQ-S Data is based on Spot optic, except for 18W. *18W is VNSP only. 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 2 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads Model SPEQ-S-A17† (small) SPEQ-M-A17† (medium) SPEQ-L-A17† (large) Wattage SM MD LG 9 18 33 15 21 41 26 48 Finish WT - white texture BT - black texture ST - silver texture Other fi nishes, consult factory Mounting TN1 - Global 1cir/H-Style, 120V TEK - Global 2cir/2neut, 120V TN3 - Global 3cir, 120V TN2 - Global 2cir/2neut, 277V CT - J-Style, 120V LOL - L-Style, 120V B* - busway, 120V/277V C - canopy, 120V/277V CCL2-SCP - C-clamp, black, with straight cord**, 6’ CCL2-CCP - C-clamp, black, with coil cord**, 5’ Notes: *Black busway adapter used for ST fi nish **Black cord used for BT & ST fi nish, White cord used for WT fi nish Voltage 120 277 (not available on SPEQ-S and SPEQ-M (18W only)) Beam Spreads SM MD LG SP - spot 15° VNSP - very SP - spot 15° NF - narrow fl ood 22° narrow spot 8° FL - fl ood 25° MFL - med fl ood 25° (18W only) WF - wide FL - fl ood 28° SP - spot 15° fl ood 36° WF wide fl ood 45° VNF - very VWF - very wide narrow fl ood 18° fl ood 60° NF - narrow LS - linear spread fl ood 23° 60° x 10° FL - fl ood 34° WF - wide fl ood 44° Color Temp 83 CRI: 90+ CRI: 27 - 2700K-83 229†† - 2200K-90+ CRISP - CrispWhite 30 - 3000K-83 279 - 2700K-90+ 3CLA - 3K Class A 35 - 3500K-83 309 - 3000K-90+ 40 - 4000K-83 359 - 3500K-90+ 409 - 4000K-90+ ††Note: available for SPEQ-S & SPEQ-M only Driver LE/TE - TRIAC/ELV dimming SPEQ-S/M (18W): 120V only SPEQ-M (21W/26W)/SPEQ-L: 120V/277V Options/Accessories SN - snoot HEX - hexcell louver SOL - solite beam softening lens LS - linear spread lens CB - cross blade (requires snoot) † The "A" refers to the sequential revision in a year and "xx" refers to the year of update. Updates coincide with improved performance while not changing the overall fi xture aesthetic and are refl ected in the published performance data. Please contact your Amerlux representative for explanations of changes. 1 2 3 4 5 6 7 8 8 9 Ordering Information 1 2 3 4 5 6 7 9 Availability: 7/21/17 SPEQ-M/SPEQ-L 9/8/17 SPEQ-S L-6535 E HYMAN, UNIT 108, ASPEN SPEQ-M-A17 21 BT TN1 120 FL 309 LE/TE SN-SOL 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 3 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsSpecifi cations Application Retail, Museum, Gallery, Hospitality and Commercial accent and display lighting Construction Complete die-cast aluminum construction No exposed wiring Unique magnetic dual lock front door Tilt indicating marks for common tilt positioning SPEQ-M and SPEQ-L feature tilt locking mechanism Optical 0-90º tilt, 360º rotation (tilt lock on Medium & Large) Small uses an Amerlux Designed TIR optical system Medium use a Patented Amerlux designed TIR optical system. Large uses an Amerlux designed Refl ector optical system. Beam Spreads vary by fi xture size. Please see Specifi cation on Page 2. LED Colo r Temp Options: 2200K†††, 2700K, 3000K, 3500K, 4000K, CRISP, Class A CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) 90+ typ. (2200K†††, 2700K, 3000K, 3500K) CrispWhite* and Class A** LEDs available R9 Values: 11 (83 CRI), 55 (90+ CRI) Binning: 3 MacAdam (SDCM) Life: 50,000+ hrs, > 70% of initial lumens at 50,000 hrs *CrispWhite: CrispWhite Technology delivers the warmth of colors expected from a high 90 CRI solution but also creates the natural crisp white color similar to CMH sources. It creates impactful lighting by revealing the richest whites and vibrant colors that pop. **Class A LED: Class A LED’s have a CRI > 80 and a GAI > 80. CRI defi nes color “Naturalness” and GAI defi nes color “Saturation.” Both being high delivers rich colors and pure whites. †††Available on SPEQ-S and SPEQ-M only Electrical Wattage: SM: 9, 15 MD: 18, 21, 26 LG: 33, 41, 48 Electronic constant current LED driver, 120V/277V input This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Amerlux® recommends using additional surge protection with this unit (supplied by others), surge damage is not covered under warranty. Driver LE/TE - Leading Edge (Triac, Forward Phase) or Trailing Edge (ELV, Reverse Phase) autosensing driver dims down to less than 5% on most dimming system. Note: 120V only on SPEQ-S and SPEQ-M (18W); 120V/277V on SPEQ-M (21W/26W) and SPEQ-L See dimming pages for more information. Finish Powder coat paint. Standard colors: White Texture, Black Texture, Silver Texture Consult factory for custom RAL powder coat fi nishes Mounting Track, canopy, c-clamp and busway. Note: Ceiling mounted track only Certifi cations Approved to UL standards as tested by CSA. Intended for indoor use only. Warranty 5 year limited warranty 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 4 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads6 15/16”1 1/16”7 3/8”9 1/2”6 1/2”Ø3 7/8” Ø5 1/8” 4 15/16”3 1/8”4”5”4 3/4” 3 5/16”5 9/16”6 1/4”4 5/16”1”2 7/16”5 15/16”Ø2 3/4” Ø1 5/8” SPEQ-S SPEQ-M SPEQ-L 3 5/16”8 7/8”6 3/16” 6 1/4”1 1/8”Shown with TN1 adapter Shown with TN1 adapter Shown with TN1 adapter 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 5 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsSPEQ-S SNOOT & ACCESSORIES SPEQ-M SNOOT & ACCESSORIES SPEQ-L SNOOT & ACCESSORIES Clear Lens Linear Spread Lens Linear Spread Lens Linear Spread Lens Solite Lens Solite Lens Clear Lens Hexcell Louver Hexcell Louver Front Door Front Door Snoot Snoot Solite Lens Prismatic Lens Hexcell Louver Snoot Front Door Snoot Cross Blade (requires snoot) Cross Blade (requires snoot) 3 5/16”Ø1 5/8” 1 5/16”5 15/16”5”9”1 3/4” 2 3/8”8 7/8”5 9/16”4 5/16”7 3/8”Ø2 3/4” Cross Blade (requires snoot) Ø3 7/8” Ø5 1/8” 6 3/16”4 7/8”11 5/8”6 3/4”6 3/8”8 11/16”8 7/8”Snoot Snoot Shown with TN1 adapter Shown with TN1 adapter Shown with TN1 adapter 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 6 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60º Candelas at Nadir Deg Candela 0 5995 5 5113 15 1733 25 345 35 101 45 38 MEDIUM FLOODMedium Flood (MFL), 25° LTL # 11756217.03 Lumens: 1,192 Candelas at Nadir Deg Candela 0 9393 5 7082 15 1786 25 268 35 86 45 27 Spot (SP), 15° LTL # 11756217.01 Lumens: 1,310 SPOT D FC L W 5.0’ 375 1.5 1.5 7.5’ 167 2.3 2.3 10.0’ 94 3.1 3.1 12.5’ 60 3.8 3.8 D FC L W CB 5.0’ 242 2.1 1.7 3.0 7.5’ 108 3.1 2.7 4..0 10.0’ 60 4.1 3.6 6.0 12.5’ 40 5.0 4.4 7.0 D FC L W CB 5.0’ 155 2.5 2.2 3.0 7.5’ 72 3.6 3.2 4.0 10.0’ 40 4.8 4.3 5.0 12.5’ 26 6.0 5.3 7.0 D FC L W CB 5.0’ 119 2.8 2.6 3.0 7.5’ 54 4.1 3.7 4.0 10.0’ 30 5.5 5.0 5.0 12.5’ 19 7.0 6.3 6.0 D FC L W 5.0’ 272 1.7 1.7 7.5’ 116 2.8 2.8 10.0’ 64 3.6 3.6 12.5’ 41 4.6 4.6 D FC L W 5.0’ 166 2.3 2.3 7.5’ 74 3.4 3.4 10.0’ 42 4.5 4.5 12.5’ 27 5.6 5.6 D FC L W CB 3.0’ 141 3.3 1.8 5.0 4.0’ 85 4.1 2.4 6.0 5.0’ 53 5.2 3.0 8.0 6.0’ 38 6.3 3.5 9.0 D FC L W CB 3.0’ 513 1.7 1.2 2.0 4.0’ 364 1.7 1.4 2.0 5.0’ 235 2.1 1.7 3.0 6.0’ 162 2.6 2.2 3.0 D FC L W CB 3.0’ 108 3.3 1.9 4.0 4.0’ 59 4.6 2.8 6.0 5.0’ 39 5.5 3.3 7.0 6.0’ 27 6.9 4.0 8.0 D FC L W CB 3.0’ 353 1.9 1.3 2.0 4.0’ 249 1.9 1.6 2.0 5.0’ 151 2.5 2.2 3.0 6.0’ 111 3.0 2.6 3.0 D FC L W CB 3.0’ 83 3.6 2.4 4.0 4.0’ 47 4.7 3.0 5.0 5.0’ 30 6.0 3.8 6.0 6.0’ 21 7.4 4.7 8.0 D FC L W CB 3.0’ 252 2.2 1.6 2.0 4.0’ 177 2.3 2.0 2.0 5.0’ 105 3.0 2.7 3.0 6.0’ 79 3.5 3.1 3.0 Candelas at Nadir Deg Candela 0 4146 5 3736 15 1748 25 480 35 129 45 48 Narrow Flood (NF), 22° LTL # 11756217.02 Lumens: 1,204 NARROW FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) SPEQ-S (for SPEQ-M data see page 6; for SPEQ-L data see page 7) CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) Wattage: 9W 15W Factor: 0.62 1.0 0 15 30 45 60 75 90 2250 4500 6750 9000 0 15 30 45 60 75 90 1500 3000 4500 6000 0 15 30 45 60 75 90 1000 2000 3000 4000 APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 15W LED, 3000K (For FL, WF & VWF beam options see pg 7) 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 7 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60º Candelas at Nadir Deg Candela 0 1987 5 1904 15 1378 25 702 35 259 45 88 VERY WIDE FLOODVery Wide Flood (VWF), 60° LTL # 11756217.06 Lumens: 1,158 Candelas at Nadir Deg Candela 0 3558 5 3263 15 1717 25 539 35 144 45 51 Flood (FL), 28° LTL # 11756217.04 Lumens: 1,184 FLOOD D FC L W 5.0’ 143 2.5 2.5 7.5’ 64 3.6 3.6 10.0’ 36 4.9 4.9 12.5’ 23 6.1 6.1 D FC L W 5.0’ 80 3.3 3.3 7.5’ 36 5.0 5.0 10.0’ 20 6.6 6.6 12.5’ 13 8.3 8.3 D FC L W 5.0’ 32 5.4 5.4 7.5’ 14 8.1 8.1 10.0’ 8 10.9 10.9 12.5’ 5 14.1 14.1 D FC L W CB 3.0’ 73 3.6 2.6 4.0 4.0’ 43 4.8 3.3 5.0 5.0’ 28 6.1 4.0 6.0 6.0’ 19 7.5 4.9 7.0 D FC L W CB 3.0’ 219 2.3 1.7 1.0 4.0’ 154 2.5 2.3 2.0 5.0’ 92 3.3 2.9 2.0 6.0’ 69 3.7 3.4 3.0 D FC L W CB 3.0’ 55 3.8 2.9 3.0 4.0’ 31 4.9 3.8 4.0 5.0’ 20 6.3 4.9 5.0 6.0’ 14 7.6 5.8 6.0 D FC L W CB 3.0’ 154 2.4 2.1 1.0 4.0’ 88 3.3 3.0 2.0 5.0’ 58 4.0 3.6 2.0 6.0’ 40 4.9 4.5 3.0 D FC L W CB 3.0’ 40 3.4 3.5 2.0 4.0’ 22 4.6 5.0 2.0 5.0’ 15 5.5 6.0 3.0 6.0’ 10 6.8 7.4 4.0 D FC L W CB 3.0’ 73 3.2 3.4 1.0 4.0’ 43 4.2 4.3 1.0 5.0’ 28 5.3 5.4 1.0 6.0’ 19 6.3 6.7 1.0 Candelas at Nadir Deg Candela 0 792 5 783 15 735 25 629 35 440 45 231 Wide Flood (WF), 45° LTL # 11756217.05 Lumens: 1,171 WIDE FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) SPEQ-S (for SPEQ-M data see pages 8-9; for SPEQ-L data see page 10) CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) Wattage: 9W 15W Factor: 0.62 1.0 0 15 30 45 60 75 90 1000 2000 3000 0 15 30 45 60 75 90 500 1000 1500 2000 0 15 30 45 60 75 90 200 400 600 800 APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 15W LED, 3000K (For SP, NF & MFL beam options see pg 6) D FC L W CB 5.0’ 119 2.8 2.6 3.0 7.5’ 54 4.1 3.7 4.0 10.0’ 30 5.5 4.9 5.0 12.5’ 19 7.0 6.3 6.0 D FC L W CB 5.0’ 57 3.9 3.6 2.0 7.5’ 26 5.9 5.4 3.0 10.0’ 14 7.8 7.3 4.0 12.5’ 9 9.9 9.2 5.0 D FC L W CB 5.0’ 27 5.1 5.5 1.0 7.5’ 12 7.9 8.3 2.0 10.0’ 7 9.4 10.0 2.0 12.5’ 5 13.9 14.6 3.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 8 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60º Candelas at Nadir Deg Candela 0 13840 5 10980 15 2848 25 1022 35 130 45 34 NARROW FLOODNarrow Flood (NF), 23º LTL # 11756217.10 Lumens: 2,211 Candelas at Nadir Deg Candela 0 14900 5 11130 15 1618 25 675 35 263 45 117 Spot (SP), 15º LTL # 11756217.08 Lumens: 2,056 SPOT D FC L W 5.0’ 595 1.2 1.2 7.5’ 265 2.0 2.0 10.0’ 149 2.7 2.7 12.5’ 96 3.3 3.3 D FC L W 5.0’ 553 1.4 1.4 7.5’ 246 2.3 2.3 10.0’ 139 3.0 3.0 12.5’ 89 3.6 3.6 D FC L W 5.0’ 420 2.0 2.0 7.5’ 187 3.1 3.1 10.0’ 105 4.1 4.1 12.5’ 68 5.1 5.1 D FC L W CB 3.0’ 223 2.9 1.4 5.0 4.0’ 135 3.6 1.8 6.0 5.0’ 85 4.5 2.7 8.0 6.0’ 60 5.3 3.0 9.0 D FC L W CB 3.0’ 810 1.3 1.2 2.0 4.0’ 576 1.5 1.2 2.0 5.0’ 372 1.9 1.4 3.0 6.0’ 256 2.2 1.7 3.0 D FC L W CB 3.0’ 210 3.4 1.6 4.0 4.0’ 130 4.1 2.1 6.0 5.0’ 82 5.3 2.8 7.0 6.0’ 58 6.3 3.3 9.0 D FC L W CB 3.0’ 781 1.6 1.2 2.0 4.0’ 553 1.7 1.3 2.0 5.0’ 347 2.1 1.6 3.0 6.0’ 246 2.4 1.9 3.0 D FC L W CB 3.0’ 200 3.4 2.1 4.0 4.0’ 110 4.5 2.9 5.0 5.0’ 72 5.6 3.5 7.0 6.0’ 50 6.9 4.2 8.0 D FC L W CB 3.0’ 636 2.0 1.4 2.0 4.0’ 448 2.1 1.8 2.0 5.0’ 265 2.7 2.4 3.0 6.0’ 199 3.1 2.8 3.0 Candelas at Nadir Deg Candela 0 10490 5 9345 15 3601 25 574 35 115 45 38 Very Narrow Flood (VNF), 18º LTL # 11756217.09 Lumens: 2,261 VERY NARROW FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) Wattage: 21W 26W Factor: 0.80 1.0 CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) SPEQ-M (for SPEQ-S beam options see pages 6-7; for SPEQ-L beam options see page 10) 0 15 30 45 60 75 90 2500 5000 7500 10000 12500 15000 0 15 30 45 60 75 90 2500 5000 7500 10000 12500 0 15 30 45 60 75 90 2500 5000 7500 10000 APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 26W LED, 3000K (For FL & WF beam options see pg 9; For VNSP (18W only) beam option see pg 9) D FC L W CB 5.0’ 384 1.7 1.4 3.0 7.5’ 171 2.6 2.3 4.0 10.0’ 95 3.6 3.1 6.0 12.5’ 63 4.3 3.8 7.0 D FC L W CB 5.0’ 357 2.0 1.6 3.0 7.5’ 162 2.9 2.7 4.0 10.0’ 88 4.0 3.4 6.0 12.5’ 59 4.8 4.1 7.0 D FC L W CB 5.0’ 271 2.7 2.4 3.0 7.5’ 127 3.8 3.4 4.0 10.0’ 72 5.1 4.6 5.0 12.5’ 45 6.5 5.8 6.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 9 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsAPPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC 0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 30º30º60º Candelas at Nadir Deg Candela 0 4086 5 3945 15 3033 25 1207 35 373 45 129 VERY NARROW SPOT18W ONLYVery Narrow Spot (VNSP), 8º LTL # 11756217.13 Lumens: 1,215 Candelas at Nadir Deg Candela 0 5,225 5 4981 15 3308 25 1054 35 241 45 77 Flood (FL), 34° LTL # 11756217.11 Lumens: 2,113 FLOOD D FC L W 5.0’ 210 3.0 3.0 7.5’ 93 4.4 4.4 10.0’ 53 5.9 5.8 12.5’ 34 7.4 7.4 D FC L W 5.0’ 164 3.3 3.3 7.5’ 73 5.1 5.1 10.0’ 41 6.7 6.8 12.5’ 27 8.4 8.5 D FC L W 5.0’ 1065 1.0 1.0 7.5’ 475 1.1 1.1 10.0’ 267 1.4 1.4 12.5’ 171 1.8 1.8 D FC L W CB 3.0’ 140 3.3 2.7 3.0 4.0’ 78 4.5 3.4 4.0 5.0’ 50 5.5 4.3 6.0 6.0’ 35 6.7 5.1 7.0 D FC L W CB 3.0’ 448 2.2 1.6 1.0 4.0’ 264 2.7 2.5 2.0 5.0’ 167 3.3 3.0 2.0 6.0’ 112 4.0 3.8 3.0 D FC L W CB 3.0’ 120 3.2 2.7 3.0 4.0’ 68 4.4 3.6 4.0 5.0’ 44 5.4 4.7 5.0 6.0’ 30 6.6 5.5 6.0 D FC L W CB 3.0’ 332 2.3 2.0 1.0 4.0’ 182 3.2 3.0 2.0 5.0’ 122 3.9 3.5 2.0 6.0’ 84 4.7 4.5 2.0 D FC L W CB 3.0’ 437 1.5 1.0 5.0 4.0’ 220 2.4 1.1 7.0 5.0’ 149 2.7 1.2 8.0 6.0’ 104 3.3 1.6 10.0 D FC L W CB 3.0’ 1155 1.0 1.0 2.0 4.0’ 856 1.1 1.0 2.0 5.0’ 729 1.0 1.0 3.0 6.0’ 372 1.8 1.1 3.0 Candelas at Nadir Deg Candela 0 26810 5 10210 15 536 25 406 35 152 45 64 Wide Flood (WF), 44º LTL # 11756217.12 Lumens: 2,145 WIDE FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) ˜˜18W ONLY˜˜ 0 15 30 45 60 75 90 1250 2500 3750 5000 0 15 30 45 60 75 90 1000 2000 3000 4000 0 15 30 45 60 75 90 7500 15000 22500 CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) Wattage: 21W 26W Factor: 0.80 1.0 SPEQ-M (for SPEQ-S beam options see pages 6-7; for SPEQ-L beam options see page 10) 26W LED, 3000K (For SP, VNF & NF beam options see pg 8) D FC L W CB 5.0’ 148 3.5 3.2 2.0 7.5’ 66 5.2 4.9 3.0 10.0’ 37 7.0 6.5 4.0 12.5’ 24 8.8 8.1 5.0 D FC L W CB 5.0’ 121 3.8 3.5 2.0 7.5’ 54 5.6 5.4 3.0 10.0’ 30 7.6 7.3 4.0 12.5’ 20 9.6 9.2 5.0 D FC L W CB 5.0’ 764 1.0 1.0 3.0 7.5’ 289 1.8 1.3 4.0 10.0’ 177 2.1 1.6 6.0 12.5’ 116 2.4 2.2 7.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 10 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60ºNARROW FLOODWide Flood (WF), 36º LTL # 11756217.19 Lumens: 3,355 Spot (SP), 15º LTL # 11756217.17 Lumens: 3,977 SPOT D FC L W 5.0’ 1870 1.2 1.2 7.5’ 832 1.6 1.6 10.0’ 469 2.3 2.3 12.5’ 300 2.8 2.8 D FC L W 5.0’ 523 2.2 2.2 7.5’ 233 3.3 3.3 10.0’ 131 4.3 4.3 12.5’ 84 5.4 5.4 D FC L W 5.0’ 295 3.2 3.2 7.5’ 131 4.6 4.6 10.0’ 74 6.1 6.1 12.5’ 48 7.7 7.7 D FC L W CB 3.0’ 700 2.5 1.3 5.0 4.0’ 397 3.1 1.5 6.0 5.0’ 262 3.9 2.1 8.0 6.0’ 177 4.9 2.7 9.0 D FC L W CB 3.0’ 2390 1.2 1.1 2.0 4.0’ 1714 1.4 1.1 2.0 5.0’ 1167 1.5 1.2 3.0 6.0’ 763 2.1 1.4 3.0 D FC L W CB 3.0’ 251 3.8 2.3 4.0 4.0’ 142 4.9 3.0 5.0 5.0’ 89 6.3 3.8 6.0 6.0’ 64 7.8 4.5 8.0 D FC L W CB 3.0’ 784 2.2 1.5 2.0 4.0’ 552 2.2 1.9 2.0 5.0’ 330 2.9 2.6 3.0 6.0’ 246 3.4 3.0 3.0 D FC L W CB 3.0’ 184 3.9 2.9 3.0 4.0’ 104 4.9 3.9 4.0 5.0’ 67 6.4 4.9 5.0 6.0’ 47 7.7 5.6 6.0 D FC L W CB 3.0’ 532 2.4 2.1 1.0 4.0’ 323 3.0 2.9 2.0 5.0’ 206 3.8 3.5 2.0 6.0’ 144 4.6 4.1 3.0 Candelas at Nadir Deg Candela 0 7358 5 6950 15 4652 25 2491 35 339 45 23 Candelas at Nadir Deg Candela 0 13050 5 11530 15 5156 25 1877 35 161 45 36 Candelas at Nadir Deg Candela 0 46860 5 30380 15 3118 25 1514 35 94 45 19 Flood (FL), 25º LTL # 11756217.18 Lumens: 3,538 VERY NARROW FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) Wattage: 33W 41W 48W Factor: 0.73 0.87 1.0 CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. SPEQ-L (for SPEQ-S beam options see pages 6-7; for SPEQ-M beam options see pages 8-9) 0 15 30 45 60 75 90 12500 25000 37500 0 15 30 45 60 75 90 2500 5000 7500 10000 12500 0 15 30 45 60 75 90 1750 3500 5250 7000 D FC L W CB 5.0’ 1206 1.4 1.2 3.0 7.5’ 526 2.3 1.8 4.0 10.0’ 297 3.0 2.7 6.0 12.5’ 198 3.6 3.2 7.0 D FC L W CB 5.0’ 337 2.9 2.6 3.0 7.5’ 157 4.1 3.7 4.0 10.0’ 88 5.5 4.9 5.0 12.5’ 56 6.9 6.1 7.0 D FC L W CB 5.0’ 202 3.8 3.5 2.0 7.5’ 90 5.7 5.2 4.0 10.0’ 52 7.6 6.9 5.0 12.5’ 34 9.5 8.7 6.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 11 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsDIMMING COMPATIBILITY: Amerlux® Speq fi xtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming confi guration as the exact full confi guration (Dimmer, Fixture Quantity, Voltage, etc) may aff ect dimming performance. TRIAC (Forward Phase) DIMMING (Standard) Utilizes “Standard” incandescent dimmers that are in wide use in installations across the US. . Notes: • 120V or 277V* • Dims down to less than 5% light output (most cases) • Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! • Must meet dimmer Minimum Load Requirements per dimming manufacturer Lutron “Diva” Lutron “Nova-T” Lutron “Maestro” Lutron “Vareo” Lutron “Skylark” ETC “SR” Rack w/D20 Module Lutron “GP” Panel ETC “DRD” Rack w/D20 Module Lutron Grafi k Eye QS Compatible Dimmers Wall Box (Incandescent Style, Wattage as required)Central System TRIAC Wiring Diagram ELV - Electronic Low Voltage (Reverse Phase) DIMMING (Standard) Utilizes specialized “ELV” dimmers. Notes: • 120V or 277V* • Dims down to less than 5% light output (most cases) • Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! • Must meet dimmer Minimum Load Requirements per dimming manufacturer Lutron “Diva” Lutron “Nova-T” Lutron “Maestro” Leviton “Surslide” Lutron “Vareo” Lutron “Skylark” Leviton “Vizio” ETC “SR” Rack w/ELV10 Module Lutron “GP” Panel with PHPM-PA Interface ETC “DRD” Rack w/ELV10 Module Lutron Grafi k Eye QS with PHPM-PA Interface Compatible Dimmers Wall Box (ELV Style)Central System Black White Green Red Black V+ V- Driver Line Neutral TRIAC Dimming Control Neutral ELV Wiring Diagram Black White Green Red Black V+ V- Driver Line Neutral ELV Dimming Control NeutralGround Ground Ground Ground Line Line Notes: * Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. 08/14/2018 Passion. Power. Performance. Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 1 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance.SPEQ Cylinder Track HeadsFeatures Designed to let the interior design and not the lighting take center stage, the SPEQ track head from Amerlux balances clean, minimal aesthetic design with industry leading optical performance. The fi xture has no visible heat sink or venting and has snoot perfectly matched to provide excellent glare control while maintaining the clean fi xture lines. The integral driver is fully featured with low end dimming and full 2.5 KV surge protection (not a lamp driver!) Perfect for Galleries, Retail and Commercial interiors SPEQ uses high end optical designs to ensure your space is lit perfectly and effi ciently. PROJECT: TYPE: 55 Electrical Data 9W 15W 18W 21W System Watts Amps System Watts Amps System Watts Amps System Watts Amps 120V 9 0.08 15 0.13 18 0.15 21.4 0.18 277V N/A N/A N/A N/A N/A N/A 21.8 0.08 26W 33W 41W 48W System Watts Amps System Watts Amps System Watts Amps System Watts Amps 120V 26 0.22 33 0.28 41 0.34 48 0.40 277V 26 0.09 33 0.12 41 0.15 48 0.17 Electronic constant current LED driver SPEQ Cylinder Track Heads Product Overview Type: Track Accent & Display SM MD LG Wattage (max): 15W 26W 48W Lumen Output: 1,310 2,056 3,977 LPW: 89.5 78.4 82.8 CBCP: 9,393 14,898 46,856 Color Temp: 2200K, 2700K, 3000K, 3500K, 4000K CRI: 83 typ. & 90+ typ. CrispWhite & 3K Class A LED's available Dimming: TRIAC & ELV (120V/277V) - 5% Dim Watts Delivered Lumens LPW CBCP Color Temp 9 812 91 5,824 3000K-83 15 1,310 89.5 9,393 3000K-83 18* 1,215 68.6 26,813 3000K-83 21 1,850 88 13,578 3000K-83 26 2,056 78.4 14,898 3000K-83 33 2,903 88.2 34,204 3000K-83 41 3,460 84.4 40,764 3000K-83 48 3,977 82.8 46,856 3000K-83 Performance Chart Fixture Summary (see following pages for more information)SmallMediumLargeSmall Medium Large Availability: 7/21/17 SPEQ-M/SPEQ-L 9/8/17 SPEQ-S Data is based on Spot optic, except for 18W. *18W is VNSP only. 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 2 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads Model SPEQ-S-A17† (small) SPEQ-M-A17† (medium) SPEQ-L-A17† (large) Wattage SM MD LG 9 18 33 15 21 41 26 48 Finish WT - white texture BT - black texture ST - silver texture Other fi nishes, consult factory Mounting TN1 - Global 1cir/H-Style, 120V TEK - Global 2cir/2neut, 120V TN3 - Global 3cir, 120V TN2 - Global 2cir/2neut, 277V CT - J-Style, 120V LOL - L-Style, 120V B* - busway, 120V/277V C - canopy, 120V/277V CCL2-SCP - C-clamp, black, with straight cord**, 6’ CCL2-CCP - C-clamp, black, with coil cord**, 5’ Notes: *Black busway adapter used for ST fi nish **Black cord used for BT & ST fi nish, White cord used for WT fi nish Voltage 120 277 (not available on SPEQ-S and SPEQ-M (18W only)) Beam Spreads SM MD LG SP - spot 15° VNSP - very SP - spot 15° NF - narrow fl ood 22° narrow spot 8° FL - fl ood 25° MFL - med fl ood 25° (18W only) WF - wide FL - fl ood 28° SP - spot 15° fl ood 36° WF wide fl ood 45° VNF - very VWF - very wide narrow fl ood 18° fl ood 60° NF - narrow LS - linear spread fl ood 23° 60° x 10° FL - fl ood 34° WF - wide fl ood 44° Color Temp 83 CRI: 90+ CRI: 27 - 2700K-83 229†† - 2200K-90+ CRISP - CrispWhite 30 - 3000K-83 279 - 2700K-90+ 3CLA - 3K Class A 35 - 3500K-83 309 - 3000K-90+ 40 - 4000K-83 359 - 3500K-90+ 409 - 4000K-90+ ††Note: available for SPEQ-S & SPEQ-M only Driver LE/TE - TRIAC/ELV dimming SPEQ-S/M (18W): 120V only SPEQ-M (21W/26W)/SPEQ-L: 120V/277V Options/Accessories SN - snoot HEX - hexcell louver SOL - solite beam softening lens LS - linear spread lens CB - cross blade (requires snoot) † The "A" refers to the sequential revision in a year and "xx" refers to the year of update. Updates coincide with improved performance while not changing the overall fi xture aesthetic and are refl ected in the published performance data. Please contact your Amerlux representative for explanations of changes. 1 2 3 4 5 6 7 8 8 9 Ordering Information 1 2 3 4 5 6 7 9 Availability: 7/21/17 SPEQ-M/SPEQ-L 9/8/17 SPEQ-S L-6S535 E HYMAN, UNIT 108, ASPEN SPEQ-M-A17 21 BT TN1 120 NF 309 LE/TE SN-SOL 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 3 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsSpecifi cations Application Retail, Museum, Gallery, Hospitality and Commercial accent and display lighting Construction Complete die-cast aluminum construction No exposed wiring Unique magnetic dual lock front door Tilt indicating marks for common tilt positioning SPEQ-M and SPEQ-L feature tilt locking mechanism Optical 0-90º tilt, 360º rotation (tilt lock on Medium & Large) Small uses an Amerlux Designed TIR optical system Medium use a Patented Amerlux designed TIR optical system. Large uses an Amerlux designed Refl ector optical system. Beam Spreads vary by fi xture size. Please see Specifi cation on Page 2. LED Colo r Temp Options: 2200K†††, 2700K, 3000K, 3500K, 4000K, CRISP, Class A CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) 90+ typ. (2200K†††, 2700K, 3000K, 3500K) CrispWhite* and Class A** LEDs available R9 Values: 11 (83 CRI), 55 (90+ CRI) Binning: 3 MacAdam (SDCM) Life: 50,000+ hrs, > 70% of initial lumens at 50,000 hrs *CrispWhite: CrispWhite Technology delivers the warmth of colors expected from a high 90 CRI solution but also creates the natural crisp white color similar to CMH sources. It creates impactful lighting by revealing the richest whites and vibrant colors that pop. **Class A LED: Class A LED’s have a CRI > 80 and a GAI > 80. CRI defi nes color “Naturalness” and GAI defi nes color “Saturation.” Both being high delivers rich colors and pure whites. †††Available on SPEQ-S and SPEQ-M only Electrical Wattage: SM: 9, 15 MD: 18, 21, 26 LG: 33, 41, 48 Electronic constant current LED driver, 120V/277V input This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Amerlux® recommends using additional surge protection with this unit (supplied by others), surge damage is not covered under warranty. Driver LE/TE - Leading Edge (Triac, Forward Phase) or Trailing Edge (ELV, Reverse Phase) autosensing driver dims down to less than 5% on most dimming system. Note: 120V only on SPEQ-S and SPEQ-M (18W); 120V/277V on SPEQ-M (21W/26W) and SPEQ-L See dimming pages for more information. Finish Powder coat paint. Standard colors: White Texture, Black Texture, Silver Texture Consult factory for custom RAL powder coat fi nishes Mounting Track, canopy, c-clamp and busway. Note: Ceiling mounted track only Certifi cations Approved to UL standards as tested by CSA. Intended for indoor use only. Warranty 5 year limited warranty 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 4 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads6 15/16”1 1/16”7 3/8”9 1/2”6 1/2”Ø3 7/8” Ø5 1/8” 4 15/16”3 1/8”4”5”4 3/4” 3 5/16”5 9/16”6 1/4”4 5/16”1”2 7/16”5 15/16”Ø2 3/4” Ø1 5/8” SPEQ-S SPEQ-M SPEQ-L 3 5/16”8 7/8”6 3/16” 6 1/4”1 1/8”Shown with TN1 adapter Shown with TN1 adapter Shown with TN1 adapter 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 5 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsSPEQ-S SNOOT & ACCESSORIES SPEQ-M SNOOT & ACCESSORIES SPEQ-L SNOOT & ACCESSORIES Clear Lens Linear Spread Lens Linear Spread Lens Linear Spread Lens Solite Lens Solite Lens Clear Lens Hexcell Louver Hexcell Louver Front Door Front Door Snoot Snoot Solite Lens Prismatic Lens Hexcell Louver Snoot Front Door Snoot Cross Blade (requires snoot) Cross Blade (requires snoot) 3 5/16”Ø1 5/8” 1 5/16”5 15/16”5”9”1 3/4” 2 3/8”8 7/8”5 9/16”4 5/16”7 3/8”Ø2 3/4” Cross Blade (requires snoot) Ø3 7/8” Ø5 1/8” 6 3/16”4 7/8”11 5/8”6 3/4”6 3/8”8 11/16”8 7/8”Snoot Snoot Shown with TN1 adapter Shown with TN1 adapter Shown with TN1 adapter 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 6 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60º Candelas at Nadir Deg Candela 0 5995 5 5113 15 1733 25 345 35 101 45 38 MEDIUM FLOODMedium Flood (MFL), 25° LTL # 11756217.03 Lumens: 1,192 Candelas at Nadir Deg Candela 0 9393 5 7082 15 1786 25 268 35 86 45 27 Spot (SP), 15° LTL # 11756217.01 Lumens: 1,310 SPOT D FC L W 5.0’ 375 1.5 1.5 7.5’ 167 2.3 2.3 10.0’ 94 3.1 3.1 12.5’ 60 3.8 3.8 D FC L W CB 5.0’ 242 2.1 1.7 3.0 7.5’ 108 3.1 2.7 4..0 10.0’ 60 4.1 3.6 6.0 12.5’ 40 5.0 4.4 7.0 D FC L W CB 5.0’ 155 2.5 2.2 3.0 7.5’ 72 3.6 3.2 4.0 10.0’ 40 4.8 4.3 5.0 12.5’ 26 6.0 5.3 7.0 D FC L W CB 5.0’ 119 2.8 2.6 3.0 7.5’ 54 4.1 3.7 4.0 10.0’ 30 5.5 5.0 5.0 12.5’ 19 7.0 6.3 6.0 D FC L W 5.0’ 272 1.7 1.7 7.5’ 116 2.8 2.8 10.0’ 64 3.6 3.6 12.5’ 41 4.6 4.6 D FC L W 5.0’ 166 2.3 2.3 7.5’ 74 3.4 3.4 10.0’ 42 4.5 4.5 12.5’ 27 5.6 5.6 D FC L W CB 3.0’ 141 3.3 1.8 5.0 4.0’ 85 4.1 2.4 6.0 5.0’ 53 5.2 3.0 8.0 6.0’ 38 6.3 3.5 9.0 D FC L W CB 3.0’ 513 1.7 1.2 2.0 4.0’ 364 1.7 1.4 2.0 5.0’ 235 2.1 1.7 3.0 6.0’ 162 2.6 2.2 3.0 D FC L W CB 3.0’ 108 3.3 1.9 4.0 4.0’ 59 4.6 2.8 6.0 5.0’ 39 5.5 3.3 7.0 6.0’ 27 6.9 4.0 8.0 D FC L W CB 3.0’ 353 1.9 1.3 2.0 4.0’ 249 1.9 1.6 2.0 5.0’ 151 2.5 2.2 3.0 6.0’ 111 3.0 2.6 3.0 D FC L W CB 3.0’ 83 3.6 2.4 4.0 4.0’ 47 4.7 3.0 5.0 5.0’ 30 6.0 3.8 6.0 6.0’ 21 7.4 4.7 8.0 D FC L W CB 3.0’ 252 2.2 1.6 2.0 4.0’ 177 2.3 2.0 2.0 5.0’ 105 3.0 2.7 3.0 6.0’ 79 3.5 3.1 3.0 Candelas at Nadir Deg Candela 0 4146 5 3736 15 1748 25 480 35 129 45 48 Narrow Flood (NF), 22° LTL # 11756217.02 Lumens: 1,204 NARROW FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) SPEQ-S (for SPEQ-M data see page 6; for SPEQ-L data see page 7) CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) Wattage: 9W 15W Factor: 0.62 1.0 0 15 30 45 60 75 90 2250 4500 6750 9000 0 15 30 45 60 75 90 1500 3000 4500 6000 0 15 30 45 60 75 90 1000 2000 3000 4000 APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 15W LED, 3000K (For FL, WF & VWF beam options see pg 7) 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 7 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60º Candelas at Nadir Deg Candela 0 1987 5 1904 15 1378 25 702 35 259 45 88 VERY WIDE FLOODVery Wide Flood (VWF), 60° LTL # 11756217.06 Lumens: 1,158 Candelas at Nadir Deg Candela 0 3558 5 3263 15 1717 25 539 35 144 45 51 Flood (FL), 28° LTL # 11756217.04 Lumens: 1,184 FLOOD D FC L W 5.0’ 143 2.5 2.5 7.5’ 64 3.6 3.6 10.0’ 36 4.9 4.9 12.5’ 23 6.1 6.1 D FC L W 5.0’ 80 3.3 3.3 7.5’ 36 5.0 5.0 10.0’ 20 6.6 6.6 12.5’ 13 8.3 8.3 D FC L W 5.0’ 32 5.4 5.4 7.5’ 14 8.1 8.1 10.0’ 8 10.9 10.9 12.5’ 5 14.1 14.1 D FC L W CB 3.0’ 73 3.6 2.6 4.0 4.0’ 43 4.8 3.3 5.0 5.0’ 28 6.1 4.0 6.0 6.0’ 19 7.5 4.9 7.0 D FC L W CB 3.0’ 219 2.3 1.7 1.0 4.0’ 154 2.5 2.3 2.0 5.0’ 92 3.3 2.9 2.0 6.0’ 69 3.7 3.4 3.0 D FC L W CB 3.0’ 55 3.8 2.9 3.0 4.0’ 31 4.9 3.8 4.0 5.0’ 20 6.3 4.9 5.0 6.0’ 14 7.6 5.8 6.0 D FC L W CB 3.0’ 154 2.4 2.1 1.0 4.0’ 88 3.3 3.0 2.0 5.0’ 58 4.0 3.6 2.0 6.0’ 40 4.9 4.5 3.0 D FC L W CB 3.0’ 40 3.4 3.5 2.0 4.0’ 22 4.6 5.0 2.0 5.0’ 15 5.5 6.0 3.0 6.0’ 10 6.8 7.4 4.0 D FC L W CB 3.0’ 73 3.2 3.4 1.0 4.0’ 43 4.2 4.3 1.0 5.0’ 28 5.3 5.4 1.0 6.0’ 19 6.3 6.7 1.0 Candelas at Nadir Deg Candela 0 792 5 783 15 735 25 629 35 440 45 231 Wide Flood (WF), 45° LTL # 11756217.05 Lumens: 1,171 WIDE FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) SPEQ-S (for SPEQ-M data see pages 8-9; for SPEQ-L data see page 10) CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) Wattage: 9W 15W Factor: 0.62 1.0 0 15 30 45 60 75 90 1000 2000 3000 0 15 30 45 60 75 90 500 1000 1500 2000 0 15 30 45 60 75 90 200 400 600 800 APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 15W LED, 3000K (For SP, NF & MFL beam options see pg 6) D FC L W CB 5.0’ 119 2.8 2.6 3.0 7.5’ 54 4.1 3.7 4.0 10.0’ 30 5.5 4.9 5.0 12.5’ 19 7.0 6.3 6.0 D FC L W CB 5.0’ 57 3.9 3.6 2.0 7.5’ 26 5.9 5.4 3.0 10.0’ 14 7.8 7.3 4.0 12.5’ 9 9.9 9.2 5.0 D FC L W CB 5.0’ 27 5.1 5.5 1.0 7.5’ 12 7.9 8.3 2.0 10.0’ 7 9.4 10.0 2.0 12.5’ 5 13.9 14.6 3.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 8 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60º Candelas at Nadir Deg Candela 0 13840 5 10980 15 2848 25 1022 35 130 45 34 NARROW FLOODNarrow Flood (NF), 23º LTL # 11756217.10 Lumens: 2,211 Candelas at Nadir Deg Candela 0 14900 5 11130 15 1618 25 675 35 263 45 117 Spot (SP), 15º LTL # 11756217.08 Lumens: 2,056 SPOT D FC L W 5.0’ 595 1.2 1.2 7.5’ 265 2.0 2.0 10.0’ 149 2.7 2.7 12.5’ 96 3.3 3.3 D FC L W 5.0’ 553 1.4 1.4 7.5’ 246 2.3 2.3 10.0’ 139 3.0 3.0 12.5’ 89 3.6 3.6 D FC L W 5.0’ 420 2.0 2.0 7.5’ 187 3.1 3.1 10.0’ 105 4.1 4.1 12.5’ 68 5.1 5.1 D FC L W CB 3.0’ 223 2.9 1.4 5.0 4.0’ 135 3.6 1.8 6.0 5.0’ 85 4.5 2.7 8.0 6.0’ 60 5.3 3.0 9.0 D FC L W CB 3.0’ 810 1.3 1.2 2.0 4.0’ 576 1.5 1.2 2.0 5.0’ 372 1.9 1.4 3.0 6.0’ 256 2.2 1.7 3.0 D FC L W CB 3.0’ 210 3.4 1.6 4.0 4.0’ 130 4.1 2.1 6.0 5.0’ 82 5.3 2.8 7.0 6.0’ 58 6.3 3.3 9.0 D FC L W CB 3.0’ 781 1.6 1.2 2.0 4.0’ 553 1.7 1.3 2.0 5.0’ 347 2.1 1.6 3.0 6.0’ 246 2.4 1.9 3.0 D FC L W CB 3.0’ 200 3.4 2.1 4.0 4.0’ 110 4.5 2.9 5.0 5.0’ 72 5.6 3.5 7.0 6.0’ 50 6.9 4.2 8.0 D FC L W CB 3.0’ 636 2.0 1.4 2.0 4.0’ 448 2.1 1.8 2.0 5.0’ 265 2.7 2.4 3.0 6.0’ 199 3.1 2.8 3.0 Candelas at Nadir Deg Candela 0 10490 5 9345 15 3601 25 574 35 115 45 38 Very Narrow Flood (VNF), 18º LTL # 11756217.09 Lumens: 2,261 VERY NARROW FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) Wattage: 21W 26W Factor: 0.80 1.0 CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) SPEQ-M (for SPEQ-S beam options see pages 6-7; for SPEQ-L beam options see page 10) 0 15 30 45 60 75 90 2500 5000 7500 10000 12500 15000 0 15 30 45 60 75 90 2500 5000 7500 10000 12500 0 15 30 45 60 75 90 2500 5000 7500 10000 APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 26W LED, 3000K (For FL & WF beam options see pg 9; For VNSP (18W only) beam option see pg 9) D FC L W CB 5.0’ 384 1.7 1.4 3.0 7.5’ 171 2.6 2.3 4.0 10.0’ 95 3.6 3.1 6.0 12.5’ 63 4.3 3.8 7.0 D FC L W CB 5.0’ 357 2.0 1.6 3.0 7.5’ 162 2.9 2.7 4.0 10.0’ 88 4.0 3.4 6.0 12.5’ 59 4.8 4.1 7.0 D FC L W CB 5.0’ 271 2.7 2.4 3.0 7.5’ 127 3.8 3.4 4.0 10.0’ 72 5.1 4.6 5.0 12.5’ 45 6.5 5.8 6.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 9 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsAPPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC 0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 30º30º60º Candelas at Nadir Deg Candela 0 4086 5 3945 15 3033 25 1207 35 373 45 129 VERY NARROW SPOT18W ONLYVery Narrow Spot (VNSP), 8º LTL # 11756217.13 Lumens: 1,215 Candelas at Nadir Deg Candela 0 5,225 5 4981 15 3308 25 1054 35 241 45 77 Flood (FL), 34° LTL # 11756217.11 Lumens: 2,113 FLOOD D FC L W 5.0’ 210 3.0 3.0 7.5’ 93 4.4 4.4 10.0’ 53 5.9 5.8 12.5’ 34 7.4 7.4 D FC L W 5.0’ 164 3.3 3.3 7.5’ 73 5.1 5.1 10.0’ 41 6.7 6.8 12.5’ 27 8.4 8.5 D FC L W 5.0’ 1065 1.0 1.0 7.5’ 475 1.1 1.1 10.0’ 267 1.4 1.4 12.5’ 171 1.8 1.8 D FC L W CB 3.0’ 140 3.3 2.7 3.0 4.0’ 78 4.5 3.4 4.0 5.0’ 50 5.5 4.3 6.0 6.0’ 35 6.7 5.1 7.0 D FC L W CB 3.0’ 448 2.2 1.6 1.0 4.0’ 264 2.7 2.5 2.0 5.0’ 167 3.3 3.0 2.0 6.0’ 112 4.0 3.8 3.0 D FC L W CB 3.0’ 120 3.2 2.7 3.0 4.0’ 68 4.4 3.6 4.0 5.0’ 44 5.4 4.7 5.0 6.0’ 30 6.6 5.5 6.0 D FC L W CB 3.0’ 332 2.3 2.0 1.0 4.0’ 182 3.2 3.0 2.0 5.0’ 122 3.9 3.5 2.0 6.0’ 84 4.7 4.5 2.0 D FC L W CB 3.0’ 437 1.5 1.0 5.0 4.0’ 220 2.4 1.1 7.0 5.0’ 149 2.7 1.2 8.0 6.0’ 104 3.3 1.6 10.0 D FC L W CB 3.0’ 1155 1.0 1.0 2.0 4.0’ 856 1.1 1.0 2.0 5.0’ 729 1.0 1.0 3.0 6.0’ 372 1.8 1.1 3.0 Candelas at Nadir Deg Candela 0 26810 5 10210 15 536 25 406 35 152 45 64 Wide Flood (WF), 44º LTL # 11756217.12 Lumens: 2,145 WIDE FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) ˜˜18W ONLY˜˜ 0 15 30 45 60 75 90 1250 2500 3750 5000 0 15 30 45 60 75 90 1000 2000 3000 4000 0 15 30 45 60 75 90 7500 15000 22500 CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) Wattage: 21W 26W Factor: 0.80 1.0 SPEQ-M (for SPEQ-S beam options see pages 6-7; for SPEQ-L beam options see page 10) 26W LED, 3000K (For SP, VNF & NF beam options see pg 8) D FC L W CB 5.0’ 148 3.5 3.2 2.0 7.5’ 66 5.2 4.9 3.0 10.0’ 37 7.0 6.5 4.0 12.5’ 24 8.8 8.1 5.0 D FC L W CB 5.0’ 121 3.8 3.5 2.0 7.5’ 54 5.6 5.4 3.0 10.0’ 30 7.6 7.3 4.0 12.5’ 20 9.6 9.2 5.0 D FC L W CB 5.0’ 764 1.0 1.0 3.0 7.5’ 289 1.8 1.3 4.0 10.0’ 177 2.1 1.6 6.0 12.5’ 116 2.4 2.2 7.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 10 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track Heads0o Aiming Angle Horizontal Footcandles 30o Aiming Angle Horizontal Footcandles 30o Aiming Angle Vertical Footcandles 60o Aiming Angle Vertical Footcandles 30º30º60ºNARROW FLOODWide Flood (WF), 36º LTL # 11756217.19 Lumens: 3,355 Spot (SP), 15º LTL # 11756217.17 Lumens: 3,977 SPOT D FC L W 5.0’ 1870 1.2 1.2 7.5’ 832 1.6 1.6 10.0’ 469 2.3 2.3 12.5’ 300 2.8 2.8 D FC L W 5.0’ 523 2.2 2.2 7.5’ 233 3.3 3.3 10.0’ 131 4.3 4.3 12.5’ 84 5.4 5.4 D FC L W 5.0’ 295 3.2 3.2 7.5’ 131 4.6 4.6 10.0’ 74 6.1 6.1 12.5’ 48 7.7 7.7 D FC L W CB 3.0’ 700 2.5 1.3 5.0 4.0’ 397 3.1 1.5 6.0 5.0’ 262 3.9 2.1 8.0 6.0’ 177 4.9 2.7 9.0 D FC L W CB 3.0’ 2390 1.2 1.1 2.0 4.0’ 1714 1.4 1.1 2.0 5.0’ 1167 1.5 1.2 3.0 6.0’ 763 2.1 1.4 3.0 D FC L W CB 3.0’ 251 3.8 2.3 4.0 4.0’ 142 4.9 3.0 5.0 5.0’ 89 6.3 3.8 6.0 6.0’ 64 7.8 4.5 8.0 D FC L W CB 3.0’ 784 2.2 1.5 2.0 4.0’ 552 2.2 1.9 2.0 5.0’ 330 2.9 2.6 3.0 6.0’ 246 3.4 3.0 3.0 D FC L W CB 3.0’ 184 3.9 2.9 3.0 4.0’ 104 4.9 3.9 4.0 5.0’ 67 6.4 4.9 5.0 6.0’ 47 7.7 5.6 6.0 D FC L W CB 3.0’ 532 2.4 2.1 1.0 4.0’ 323 3.0 2.9 2.0 5.0’ 206 3.8 3.5 2.0 6.0’ 144 4.6 4.1 3.0 Candelas at Nadir Deg Candela 0 7358 5 6950 15 4652 25 2491 35 339 45 23 Candelas at Nadir Deg Candela 0 13050 5 11530 15 5156 25 1877 35 161 45 36 Candelas at Nadir Deg Candela 0 46860 5 30380 15 3118 25 1514 35 94 45 19 Flood (FL), 25º LTL # 11756217.18 Lumens: 3,538 VERY NARROW FLOODFIXTURE DATA: (Complete photometric data (.ies format) available upon request) Wattage: 33W 41W 48W Factor: 0.73 0.87 1.0 CCT: 2700K-83 3000K-83 3500K-83 4000K-83 Factor: 0.96 1.0 1.02 1.04 CCT: 2200K-90+ 2700K-90+ 3000K-90+ 3500K-90+ CRISP 3CLA Factor: 0.71 0.80 0.83 0.87 0.65 0.75 MULTIPLYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES fi le on website) APPLICATION DATA: D W L L WFCCB W FC CB L 30° D 30º FC Notes and Defi nitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. SPEQ-L (for SPEQ-S beam options see pages 6-7; for SPEQ-M beam options see pages 8-9) 0 15 30 45 60 75 90 12500 25000 37500 0 15 30 45 60 75 90 2500 5000 7500 10000 12500 0 15 30 45 60 75 90 1750 3500 5250 7000 D FC L W CB 5.0’ 1206 1.4 1.2 3.0 7.5’ 526 2.3 1.8 4.0 10.0’ 297 3.0 2.7 6.0 12.5’ 198 3.6 3.2 7.0 D FC L W CB 5.0’ 337 2.9 2.6 3.0 7.5’ 157 4.1 3.7 4.0 10.0’ 88 5.5 4.9 5.0 12.5’ 56 6.9 6.1 7.0 D FC L W CB 5.0’ 202 3.8 3.5 2.0 7.5’ 90 5.7 5.2 4.0 10.0’ 52 7.6 6.9 5.0 12.5’ 34 9.5 8.7 6.0 08/14/2018 Passion. Power. Performance. PROJECT: TYPE: Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com LIT-2118 • 07/17/17 • Page 11 of 11 Amerlux reserves the right to change details that do not aff ect overall function and performance. SPEQ Cylinder Track Heads SPEQ Cylinder Track HeadsDIMMING COMPATIBILITY: Amerlux® Speq fi xtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming confi guration as the exact full confi guration (Dimmer, Fixture Quantity, Voltage, etc) may aff ect dimming performance. TRIAC (Forward Phase) DIMMING (Standard) Utilizes “Standard” incandescent dimmers that are in wide use in installations across the US. . Notes: • 120V or 277V* • Dims down to less than 5% light output (most cases) • Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! • Must meet dimmer Minimum Load Requirements per dimming manufacturer Lutron “Diva” Lutron “Nova-T” Lutron “Maestro” Lutron “Vareo” Lutron “Skylark” ETC “SR” Rack w/D20 Module Lutron “GP” Panel ETC “DRD” Rack w/D20 Module Lutron Grafi k Eye QS Compatible Dimmers Wall Box (Incandescent Style, Wattage as required)Central System TRIAC Wiring Diagram ELV - Electronic Low Voltage (Reverse Phase) DIMMING (Standard) Utilizes specialized “ELV” dimmers. Notes: • 120V or 277V* • Dims down to less than 5% light output (most cases) • Consult Dimming manufacturer for installation instructions - DO NOT SHARE NEUTRALS! • Must meet dimmer Minimum Load Requirements per dimming manufacturer Lutron “Diva” Lutron “Nova-T” Lutron “Maestro” Leviton “Surslide” Lutron “Vareo” Lutron “Skylark” Leviton “Vizio” ETC “SR” Rack w/ELV10 Module Lutron “GP” Panel with PHPM-PA Interface ETC “DRD” Rack w/ELV10 Module Lutron Grafi k Eye QS with PHPM-PA Interface Compatible Dimmers Wall Box (ELV Style)Central System Black White Green Red Black V+ V- Driver Line Neutral TRIAC Dimming Control Neutral ELV Wiring Diagram Black White Green Red Black V+ V- Driver Line Neutral ELV Dimming Control NeutralGround Ground Ground Ground Line Line Notes: * Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. 08/14/2018 EMERGENCY EDG-EDGR Catalog Number Notes Type ORDERING INFORMATION For shortest lead times, configure products using bolded options.Example: EDG 1 R EL Family Housing color Number of faces Letter color Operations Options EDG Surface mount LED edge-lit exit EDGR Recessed LED edge-lit exit (blank)Brushed aluminum W White 1 Single face 2 Double face R Red on clear (single face only)1 G Green on clear (single face only)1 RMR Red on mirror2 GMR Green on mirror2 RW Red on white3 GW Green on white3 (blank)AC only EL Nickel-cadmium battery X2 Lamp wired on two separate AC circuits (specify 120V or 277V)4 SD Self-diagnostics5 (blank)None WM Recessed wall mount6 Accessories: Order as separate item. ELA US12 12” stem kit with brushed aluminum canopy7 ELA W US12 12” stem kit with white canopy7 FEATURES & SPECIFICATIONS INTENDED USE — Suitable for applications requiring attractive edge-lit exit signage, universal installa- tion and low energy consumption. CONSTRUCTION — Extruded brushed aluminum finish. Clear acrylic panels- letters measure 6” high with 3/4” stroke, with 100 ft viewing distance rating, based upon UL 924 standard. For single-face clear panels, EXIT is seen as a reversed image from the back. OPTICS — LEDs mounted on printed circuit board. The typical life of the exit LED lamp is 10 years. The LED operating frequency is 120Hz. ELECTRICAL — Dual voltage input capacity (120/277V). Battery: (EL Option) – Sealed, maintenance free nickel-cadmium battery delivers 90 minutes capacity to emergency lamps. Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostic testing (EL Option Only) for 30 seconds every 30 days and 90 minutes annually. Diagnostic evaluation of LED light source, AC to DC transfer, charging and battery condition. INSTALLATION — EDG – Universal surface (top, end or back) mounting. Canopy provided. EDGR – Recessed mounting. Bar hanger and brackets provided for both new or restricted ceiling access installation applications. Back wall mount (WM) option. Universal directional indicators. Field selected and attached. LISTINGS — UL damp location listed 32°-122°F (0°-50°C) standard. Meets UL924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. WARRANTY — 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx NOTE: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25°C. Specifications subject to change without notice. LED Edge-Lit Exits EDG EDGR LED Lamps Notes 1 For single-face clear panels, EXIT is seen as a reversed image from the back. 2 Available with single and double face. 3 White panel standard for double and single face. 4 Not available with EL and SD options. Both circuits can be energized at the same time. 5 Available with EL option only. 6 Available on EDGR single face only 7 See spec sheet ELA-StemKits. Only available for EDG. All dimensions are inches (centimeters) unless otherwise noted. EDG (surface mount) EDGR (recessed mount) Specifications EDG (End Mount) EDG (Top Mount) Length: 13-5/8 (34.6) Length: 13 (33.0) Depth: 5-1/2(14.0) Depth: 4-5/16 (11.0) Height: 11-1/8 (28.3) Height: 11-3/4 (29.8) Shipping Weight : 4 lbs (1.8 kgs) Shipping Weight : 4 lbs (1.8 kgs) EDG (Back Mount) EDGR Length: 13 (33.0) Length: 13 (33.0) Depth: 3 (7.6) Depth: 1-3/4 (4.4) Height: 11-1/8 (28.3) Height: 8 (20.3) Shipping Weight : 4 lbs (1.8 kgs) Shipping Weight : 6.8 lbs (3.1 kgs) Shipping Weight (WM option) : 8.1 lbs (3.7 kgs) EDG-1-G-EL 535 E HYMAN, UNIT 108, ASPEN X 08/14/2018 EDG-EDGR EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com © 2003-2017 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/21/17 SPECIFICATIONS KEY FEATURES EDG-EDGR LED, Surface and Recessed Mount Edge-Lit Exits Notes 1 Based on continuous operation. The typical life of the exit LED lamp is 10 years. 2 At 77°F (25°C). 3 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties. 4 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Universal chevron indicators for field selection/installation. Test Switch Pilot Light (Emergency Only) Back Mount End Mount Top Mount 4-5/16(11.0) 11-3/4(29.8) 11-1/8(28.3) 13-5/8(34.6) 12-3/4 (32.4) 5-1/2(14.0) 12-1/8(30.8) 3(7.6) 1/2(1.3) 11-1/8 (28.3) 4-3/8(11.1) 13 (33.0) 12-3/4(32.4) 3/8(1.0) ELECTRICAL Primary Circuit Type Typical LED life1 Supply voltage EDG EDGR Input Watts Max amps. Input Watts Max amps. Red LED AC only 10 years 120 2.5 0.020 3.8 0.030 277 2.8 0.010 4.5 0.014 Green LED AC only 10 years 120 2.2 0.020 3.8 0.030 277 2.2 0.010 4.5 0.020 Red LED emer- gency 10 years 120 3.0 0.030 3.8 0.031 277 3.1 0.010 4.5 0.015 Green LED emergency 10 years 120 2.6 0.020 3.8 0.031 277 2.8 0.010 4.5 0.020 13(33.0)1-3/4(4.4) 8(20.3) EDG EDGR BATTERY (EL option) Sealed Nickel-Cadmium Shelf life2 Typical life2 Maintenance3 Optimum temperature4 3 years 7-9 years none 32-122°F (0-50°C) 14-1/2 (36.8) 3-1/4 (8.3) 2-13/16(7.1) 5-1/2(14.0) 4-1/8(10.5) 15-3/4(40.0)8 (20.3) 13(33.0) EDGR WM option MOUNTING 08/14/2018 ELM2 LED Series Lamp type Housing Options ELM2 LED Two 1.5W/3.6V white LED (blank)White B Black HO High-output ni-cad battery for 6W remote capacity 1 SD Self-diagnostics NOM Meets Mexican standards T20C California Title 20 Compliance 2 ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: ELM2 LED Accessories: Order as separate catalog number. ELA Q L0304 SD Single LED indoor remote head, white, self-diagnostics 3,4,5 ELA Q L0304 Single LED indoor remote head, white 3,4,5 ELA T Q L0304 SD Twin LED indoor remote head, white, self-diagnostics 3,4,5 ELA T Q L0304 Twin LED indoor remote head, white 3,4,5 ELA QWP L0304 SD Single LED weather-proof remote head, gray, self-diagnostics 3,4,5 ELA QWP L0304 Single LED weather-proof remote head, gray 3,5 ELA T QWP L0304 SD Twin LED weather-proof remote head, gray, self-diagnostics ELA T QWP L0304 Twin LED weather-proof remote head, gray 3,5 ELA WG1 Wireguard, 15” W x 13-1/2” H x 6” D (See spec sheet ELA-WG)ELA VS Thermoplastic vandal shield6 EMERGENCY ELM2-LED Catalog Number Notes Type Thermoplastic Emergency Light ELM2 LED LED Lamp Head Ni-Cad Battery FEATURES & SPECIFICATIONS INTENDED USE — Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment with quick installation. Certain airborne contami- nants can diminish integrity of acrylic and/or polycarbonate. Click here for Acrylic-Polycarbonate Compatibility table for suitable uses. CONSTRUCTION — White, compact, low-profile contemporary design. Engineering-grade thermoplastic housing is impact-resistant, scratch-resistant and corrosion-proof. UL94V-O flame rating. UV-stable resin resists discoloration from natural and man-made light sources. Low-profile, integrated test switch/pilot light. Easily visible bright red status indicator. Unique track-and-swivel arrangement permits full range of direction of lamp head adjustment. Universal J-box mounting pattern. Tool-less access for maintenance. OPTICS — Two LED lamp heads with polycarbonate lens, 12 series-parallel white LEDs each, provide redundant light sources to ensure emergency lighting performance. Typical LED lamp life is 10 years. ELECTRICAL — Dual-voltage input capability (120/277V). Edge connector on printed circuit board ensures long-term durability. Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Short-circuit protection — current-limiting charger circuitry protects printed circuit board from shorts. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient tem- perature. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/ undercharging that shortens battery life and reduces capacity. Filtered charger input minimizes charge voltage ripple and extends battery life. AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. BATTERY: Sealed, maintenance-free nickel-cadmium battery delivers 90 minute capacity to emergency lamps. Two-state constant-current charge maximizes battery life and automatically recharges after battery discharge. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Optional high-output battery available to power both local and optional LED remote lamp heads simultaneously. Self -Diagnostics (SD- Option) Single multi-color LED indicator to display two-state charging, test activation and three-state diagnostic test. Test switch provides manual activation of 30-second diagnostic testing for on-de- mand visual inspection. Self-diagnostic testing for 30 seconds every 30 days, 30 minutes at 180-day interval, and 90 minutes annually. Diagnostic evaluation of LED light source, AC to DC transfer, charging and battery condition. INSTALLATION — Ceiling- or wall-mount standard. Flexible conduit entry provision on top of the unit. LISTINGS — UL damp location listed standard 50-104°F (10-40°C). Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Notes 1 Not available with NOM. 2 See T20C compliant product list. Only available with ELM2 LED B HO SD. 3 Only available with HO option. See spec sheet ELA Q LED. 4 Also available in black. Add "B" after ELA to order black finish. Example: ELA B Q L0304 SD. See spec sheet ELA Q LED. 5 Only compatible with Quantum LED series. 6 See spec sheet ELA VS-VS2. WARRANTY — 5-year limited warranty. (Battery is prorated). Complete warranty terms located at: www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx. Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. 535 E HYMAN, UNIT 108, ASPEN EM ELM2-LED-B-SD 08/14/2018 ELM2-LED EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 800.334.8694 www.lithonia.com ©2012-2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 04/10/18 ELM2 LED QUANTUM® Thermoplastic Emergency Light MOUNTING All dimensions are inches (centimeters). Shipping weight: 4.0 lbs. (1.8 kgs.) Mounting Plate 4-1/4(10.8) 10-1/4 (26.0) 2-3/4(7.0) 1/2” flexible conduit knockout 2-1/8(5.4) 4-1/4(10.8) 3-1/8(7.9) 5-1/8(13.0)10-1/4(26.0) 2-5/8(6.7) 3-5/8(9.2) * Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes open space with no obstructions, mounting height: 7.5’, ceiling height: 9’, and reflectances: 80/50/20. Analysis based on independently tested photometrics. SPECIFICATIONS 1 Based on continuous operation. 2 At 77°F (25°C). 3 All life safety equipment, including emergency lighting path of egress, must be maintained, serviced and tested in accordance with all National Fire Protection Association and local codes. Failure to perform the required maintenance, service or testing could jeopardize the safety of occupants and will void all warranties. 4 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. LAMP PHOTOMETRICS QUANTUM LED SERIES – SINGLE COVERAGE 3W Total White LEDs Using a single unit at a typical 7.5’ mounting height delivers an average illuminance of 1.0 FC over a distance of 24’ on a 3’ path of egress and 18’ on a 6’ path of egress. QUANTUM LED SERIES – MULTIPLE COVERAGE 3W Total White LEDs Using multiple units at a typical 7.5’ mounting height delivers 25’ center-to-center spacing on a 3’ path of egress and 20’ center-to-center spacing on a 6’ path of egress. 24' 3' 1 FC average 18' 1 FC average 6' 1 FC average 25' 3'6' 20' 1 FC average Example of single ELM2 LED unit illuminating a 3' path of egress Example of single ELM2 LED unit illuminating a 6' path of egress Example of multiple ELM2 LED units illuminating a 3' path of egress Example of multiple ELM2 LED units illuminating a 6' path of egress EXTENDED RUN-TIME FOR HIGH-OUTPUT UNITS Product Run time ELM2 LED HO (no remotes) 3.9 hours Electrical Primary Circuit Typical LED life1 Supply voltage Max amps Max watts HO/max watts 10 years 120 .04 1.44 2.88 277 .03 1.44 2.88 Ni-Cad Voltage Shelf life2 Typical life2 Maintenance3 Optimum temperature4 3.6 3 years 7-9 years none 50-104°F (10-40°C) BATTERY Remote Output Capacity Standard unit Unit/HO battery NA 6W 08/14/2018