PRODUCT DESCRIPTION
Heavy duty architectural grade track with two independently controllable circuits.
Stem or cable suspensions available.
FEATURES
• Power per Circuit: 1920W max (120V) , 4432W max (277V)
• Operating Current: Each circuit is rated 20A (2 x 20A = 40A max)
• Extruded aluminum construction
• UL & CUL listed
• 5 year WAC Lighting product warranty
W Track System - Surface Mount
SPECIFICATIONS
Materials: Solid copper alloy bus bars in an extruded aluminum
with a rectangular cross-sectional area of 4.2 mm2
Electrical: Electric feed capability through all jointers/feeders
(except Power Connector and Flexible Connector) using standard
2 inch knock-outs
Mounting: Fixtures may be installed or removed anywhere
along the track. Minimum fi xture spacing is 1 foot. Track fi xture
has safety interlocks when installed/removed. Polarization is
guaranteed throughout the system
Finish: Available in black powder coat (BK),
white powder coat (WT), or platinum anodized (PT) fi nishes
Standards: UL & CUL listed
–
Example: WHT4-PT
1a"
1c"
s"
ORDER NUMBER
Model Length Finish
WT
WHT
120V
277V
4
8
12
4'
8'
12'
BK
PT
WT
Black
platinum
White
Each section includes two matching end caps.
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Apr 2015
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Accessories Model Volt Finish Description
Live End
Connector –
Left polarity
WEDL
WHEDL
120V
277V
BK
PT
WT
Direct wiring through ceiling.
polarity on left side of track.
Live End
Connector
– right polarity
WEDR
WHEDR
120V
277V
Direct wiring through ceiling.
polarity on right side
of track.
"I" Connector WPC
WHPC
120V
277V
BK
PT
WT
Join two sections of track with
electrical continuity.
"I" power
Connector
WIC
WHIC
120V
277V
BK
PT
WT
power entry point at the
connection of two tracks.
Flexible
Connector
WFC
WHFC
120V
277V
BK
PT
WT
Transition from wall-to-wall,
wall-to-ceiling, or
ceiling-to-ceiling.
power feedable.
Canopy plate CP 120V
277V
BK
PT
WT
Covers a standard
4" octagonal box.
"L" Connector –
Left polarity
– WLLC
WHLLC
120V
277V BK
PT
WT
Join 2 track sections to make
power feedable 90° left
polarity turns.
"L" Connector –
right polarity
–WRLC
WHRLC
120V
277V
Join 2 track sections to make
power feedable 90° right
polarity turns.
"T" Connector
– Left
WLTC
WHLTC
120V
277V BK
PT
WT
Join 3 track sections.
power feedable.
polarity on outside edge.
"T" Connector
– right
WRTC
WHRTC
120V
277V
Join 3 track sections.
power feedable.
polarity on inside edge.
"X" Connector WXC
WHXC
120V
277V
BK
PT
WT
Join 4 track sections.
power feedable.
W Track System - Surface Mount
Suspension Model Length Finish Description
Stem Kit
With power
Feed
WMSP
6
12
24
36
48
96
6"
12"
24"
36"
48"
96"
BK
PT
WT
power feed to connect
with a Live End or any
Joiner/Feeder. May be
fi eld cut.
Flexible
power
Feed
WMFP 48
96
48"
96"
BK
PT
WT
Flexible power feed to
connect with a Live End
or any Joiner/Feeder.
recommended for use
with Cable Suspensions.
May be fi eld cut.
pendant
Stem Kit WMT-X
6
12
24
36
48
96
6"
12"
24"
36"
48"
96"
BK
PT
WT
Use to extend track from
the ceiling.
May be fi eld cut.
T–Bar
Stem Kit WMT-TB Extend track from drop
ceilings. May be fi eld cut.
Sloped
Ceiling Stem
Kit
WMT
XS6
XS12
XS24
XS36
XS48
XS96
6"
12"
24"
36"
48"
96"
BK
PT
WT
Use to extend track
from a sloped ceiling.
May be fi eld cut.
Sloped
Ceiling Cable
Kit
WMST XS48
XS96
48"
96"
BK
PT
WT
Extend track from a sloped
ceiling. May be fi eld cut.
Suspension
Cable Kit WMST-X
48
96
48"
96"
BK
PT
WT
Extend track from the
ceiling. May be fi eld cut.
T–Bar
Suspension
Cable Kit
WMST-TB Extend track from drop
ceilings. May be fi eld cut.
Suspension Accessories Model Finish
Suspension
Hanger Clip WMT
BK
PT
WT
"I" power Connector
Suspension Mount WMPC
BK
PT
WT
Live End
Suspension Mount WMED
BK
PT
WT
power Feed Coupler
Suspension Mount
Use with "I" power
Connector
WMIC
BK
PT
WT
"L" Connector
Suspension Mount WMLC
BK
PT
WT
"T" Connector
Suspension Mount WMTC
BK
PT
WT
"X" Connector
Suspension Mount WMXC
BK
PT
WT
Track Current Limiter Volt Rating Finish Description
Live end -
Left
WEDL
WHEDL
120V
277V
1A
2A
5A
7A
10A
12A
1 Amp
2.5Amp
5 Amp
7.5Amp
10Amp
12Amp
BK
PT
WT
Assures
compliance to
California Title 24
or ASHrAE 90.1
requirements Live end -
right
WEDR
WHEDR
120V
277V
A
B
C
D
A WEDR Live end connector (right)
B WIC I power connector
C WPC I connector
D WEC End cap
Straight Configuration
B
C
D
Horizontal Ceiling Mount
A
C
D
Vertical Wall-to-Ceiling Mount
A WEDR Live end connector (right)
B WEDL Live end connector (left)
C WFC Flexible connector
D WEC End cap
Flexible Configurations
B
B
D
A
C
C
A
A
A
A
B
F
G
H
I
J
A
B
D
E
F
G
H
I
J
C C
D
E
A WLLC L Connector Left
B WLTC T Connector Left
C WRTC T Connector Right
D WXC X Connector
Grid Configuration
A WMSP Stem kit with power feed
B WMED Live end suspension mount
C WEDR Live end connector (right)
D WMT-XS Sloped ceiling stem kit
E WMT Suspension hanger clip
F WMT-TB T bar stem kit
G WMT-X Stem kit
H WMLC L connector suspension mount
I WLLC L connector left
J WEC End cap
Stem Suspension Mount
A WMFP Flexible Stem kit with power feed
B WMED Live end suspension mount
C WEDL Live end connector (left)
D WMST-X Cable suspension kit
E WMT Suspension hanger clip
F WMST-TB T bar cable suspension kit
G WMST-XS Sloped ceiling cable kit
H WMLC L connector suspension mount
I WLLC L connector left
J WEC End cap
Cable Suspension Mount
Use one support for every 4 feet
= Indicates Electrical Continuity
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Apr 2015