Loading...
HomeMy WebLinkAboutFile Documents.975 Chatfield Rd.0224.2017 (6).ARBKHIGH EFFICIENCY RESIDENTIAL BOILERS --i /l E TUBE BOILEF SMART A a CON•X•US° REMOTE CONNECT CAPABLE LOCH -N -LINK" USB DRIVE SETUP 3 SETPOINTS WITH OUTDOOR RESET CURVES DHW RECIRCULATION PUMP CONTROL 95% 6I9cFanriFo. AFUE EFFICIENCYfe See back page br elfiaiency by motlel -A Lochinrm 7 MODELS: 55,000 — 399,999 BTU/HR TOP AND BOTTOM WATER CONNECTIONS" ¢= c UP TO 10:1 TURNDOWN RATIO" WALL MOUNT DESIGN USA HIGH EFFICIENCY BOILERS & WATER HEATERS Lochinvor. com 7FIR� E TUBE BO/LER MONEY -SAVING 95% EFFICIENCY AND EASIER THAN EVER TO INSTALL The KNIGHT wall mount fire tube boiler allows for a more flexible installation with top and bottom water connections'*. Multiple water connection locations add Flexibility by allowing boiler connections to be as close as possible to the system piping, reducing installation cost, complexity and the amount of piping needed for a job. The KNIGHT fire tube boiler operates with low pressure drop. The design incorporates a small volume of water in the heat exchanger allowing the boiler to be installed in a primary/secondary or a full -flow piped system. There is no need to change the piping to accommodate the boiler. The boiler adapts to the system. This Flexibility allows for a faster, more cost-effective boiler upgrade. -Not included on WHN400 Newest version of the SMART SYSTEM allows for easier setup and navigation of parameters. New features include DHW recirculation pump control, LOCK-WLINK USB programming, larger user interface, cascade leader redundancy and modulation factor for fine tuning aggressiveness. Modulation turndown up to 10:1 means the firing rate automatically changes as the heat load varies. A WHN111 KNIGHT boiler fires at its maximum 110,000 Btu/hr rate when load is highest, then "turns down" to as low as 10% (11,000 Btu/hr) as load decreases. A modulating boiler runs smoothly and efficiently, without frequent on/off cycling. `*Not included on WHN400 exhaust mns up to 100 equivalent feet, using PVC, CPUC, polypropylene or AL29-4C stainless steel vent pipe. 6 Inputs from 55,000 to 285,000 Btu/hr. See KNIGHT fire tube boiler literature (KHN) for more details. if M I CONiXcUg BOILER CONTROL, FROM ANYWHERE. From wherever you are, the CON X US option lets you use any Imernebcapable device to linkup with the SMART SYSTEM on an unlimited number of KNIGHT boilers. > Do regular CON•X•US checks for all your KNIGHT customers, and let them know you're monitoring their boiler's performance. pump delays and n using the CON X U`. interactive display. > Status alerts via text or e-mail lets you know when a KNIGHT boiler needs attention. With CON -X -US, you're always in touch and in control. Optional CON X US control board is sold separately. r r: SYSTE THE ULTIMATE IN BOILER CONTROL & MONITORING The industry's most advanced boiler control system now includes the CON -X -U5 Remote Connect option and LOCH -N -LINK USS Programming feature. See back cover fora complete list of SMART SYSTEM functions and features. w 4%e , It m w (F, . am ' r 421.1 dr Blue Screen Normal system operation -0 Yellow Screen Maintenance due shows rl`>M installer name &number L Red Screen Lockout mode KNIGHT BOILER DIMENSIONS AND SPECIFICATIONS KNIGHT BOILER RIGHT DIMENSIONS AND HOTTOM `e10:1 Tumdown Gr ound regard bottom water eonnections are not included on WHN40a. WHN40D operates with a 5:1 turndown. Ireformation subiectm em npaithout holds. Change' N^ m R^ for N gas models. The Nn AHglwam Ranngssnoxn arebaswon a roping aha vlaov slowness ". Loemnv "twelb beaonsunM bebleseletlinga boiler (or Insulators having unusual piping and ptdkuprtyulrements. such as lncenzy mMmm operation wherecNI upichnsystems. el.Theerngshavebeendeseemined undermepmvlslons governing farted d2X burners. SMART SYSTEM FEATURES > Smaw Systmn Dii Dperating Cahoot Multi Calor Graphic LCD Display w/Navigation Dial. Soft Keys and Loch N Link OSB programming I Three 8.11. Se lntTempeMum Inputs Plus Domestic Hol Water Prionlization I Bul Cgm IM Sequencer he up to 8 Boners, with pomade Redundancy Multiple size Boiler Cascade Lead Lag EDiciency Optimization Frani End Loading Capability I Outdoor Reset COntmt"h Outdoor AlrSmnar Programmable for Three Reael Temperature inputs I Pmgramm meSystem EMeiemy Goldberg SH Night Setback Dow Night Setback Anti Qeding Oustdoor Air ReseeCulve Ramp Dead Modulation Factor Control Boost Temperatme& Tom Four Pump UlrbW System Pump with Parameter for Continuous Operation Bailer Pump with Variable Speed Counted Boosted Hot Water Pump Domeld, Hot Water Reciro.lation Omne Net Water Pr MU.tlon DHW him piped with priority in the holler loop DHW tank piped as a zone in the system with Use pumps mntralled by the SMART SYSTEM DHW Modulation Ur itng Separately Adjustable Space Heat/DHW Switching Times I Built Managem ustSyMem lmepa0on 0 10 VOC Input to Canted Modulation or Selpoint 010 VOC Modulation Rate Output U 1 VOC Input m Enable/Disable Call for Heat -; Liodill1Vd-mr` & ever v,.rAmga )Ae(eaf to BMS Settln8s through Graphic ICD DIV" NlghWaltage Terminal Strip 130 VAC 160 Hertz / 1 Phase Power Supply Three Sete of Pump contacts > lowYONaP Tamagni Strip DHW Recirculation Pump Start/Stop 24 MC Device Relay Proving Switch Contacts Ron SWISH Contacts Alaml on Any Failure partnere Runtime Contacts DHW Thereabout Contacts 3 Spam Heat Thmmastat Contacts System Sensor Contacts BUSY Tank Sensor Contacts Outdoor Air Sensor Contacts Cascede Concepts OdO VDC EMS mal Contmi Contact 0-10 WC Boiler Rate Output Contacts 0-10 V IC Variable Speed System Pump Signal Input 010 WS Signal M ConVOl Variable Speed Bailer Pump Modbus Contacts )For. Clink ) gain Until Hours Running, Space Heating Noun Running, Domestic Hot Water Ignition Mtempts Last to lockouts MO... Reminder Custom Maintenance Reminder with Contractor Coup, Information Installer Ability to Deactivate Service Reminder ) lowWatm Dow Safaty CulNmt&Indira )Pmmyded Smuriq ) Cumnmlzebte Freeze P Obn Feammers 1*Not included on WHN400 sel-c' lie n o ® o lnr.,,.... STANDARD FEATURES >95%DOE MEMi nay(56286) > ModMMteg Burner with up W ao:l Tumdown" Direct Speak ignition Low NO. OPeation s ASME Stain ess Steel HM Exchanger 30 PSI ASME Relief Valve ) Top and Bottom wain connections(MNPDs• ) VmOol Ulalso stal OIrM Writ PJC, CWC, Pmyprupylemy or SS Venting uo to 100 feel asM 5Y6TEM CnMmI I CondmssteTrap OMm FMurm Automatic Reset High Limit Adjustable High Limit w/Manual Reset Beiter(iroining Pump Zero Clearances m Combustible Materials 15 year United WamnN (Sae WamnN for Drel SYwr Limited Paris Wonder OPTIONAL EQUIPMENT CORKAS Remade tenementary Modbus Communication BACrat MSTP Flow Switch Low Water CumBw/Manual Reset &Test Alarm Bell Concentric Vent gid Condensate Neutralization Kit BMS WWeay to LON or BACnet IF Multi Temperature Loop Contend Sidewali Vint TamtoaNpn Wireless Outdoor Sensor IF Gas Conversion Kit Rdng Ortlm M9 Standard Camtmction M2 California Code