Loading...
HomeMy WebLinkAboutFile Documents.975 Chatfield Rd.0224.2017 (22).ARBKSpecification Data Panasonic Ventilation Fan Description Ventilating fan shall be Low Noise ceiling mount type rated for continuous run. Fan shall be ENERGY STAR rated and certified by the Home Ventilating Institute (HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: •Four–pole totally enclosed condenser motor rated for continuous run. •Power Rating shall be 120 volts and 60 hz. •Fan shall be UL listed for tub/shower enclosure when used with a GFCI branch circuit wiring. •Motor equipped with thermal–cutoff fuse. •Removable with permanently lubricated plug–in motor. Housing: •Rust proof paint, galvanized steel body. •Detachable 4" diameter duct adapter. •Built in backdraft damper. •Expandable extension bracket up to 24". •Double hangar bar system allowing for ideal positioning. Grille: •Attractive design using PP material. •Attaches directly to housing with torsion springs. Warranty: •The factory warranty shall be a minimum of 3 years limited warranty on parts. Typical Specifications: Ventilating fan shall be of the ceiling mount, ENERGY STAR rated type, with no less than 80 CFM and no more than 0.3 sone as certified by the Home Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge. Power consumption shall be no greater than 22.8 watts and ENERGY STAR rated with efficiency rating of no less than 3.5 CFM/watt. The motor shall be totally enclosed, four pole condenser type engineered to run continuously. Power rating shall be 120v/60Hz. Duct diameter shall be no less than 4". Fan shall be UL and cUL listed for tub/shower enclosure when used with GFCI branch circuit wiring. FV-08VQ3 (80 CFM) Panasonic Home & Environment |One Panasonic Way |Secaucus, NJ 07094 |866-292-7292 |www.panasonic.com/building For Complete Installation Instructions Visit www.panasonic.com/building Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: Airo w (CFM)Static Pressure (inch w.g.)Fan Curve FV-08VQ3 14-1/2” or 24” 4”4” 7-7/8” 14-1/2” or 16” 13”13” 10-1/4”10-1/4” FV-08VQ3 4" Duct(Standard) Static Pressure (inches w.g.)0.1 0.25 Air Volume (CFM)80 57 Noise (sones)0.3 NA Power Consumption (Watts)22.8 22.6 Energy Efficiency (CFM/Watts)3.5 2.5 Speed (RPM)716 909 Current (amps)0.19 0.19 Power Rating (V/Hz)120/60 Ventilation Fan Characteristics (HVI Certified Data) California Title-24 Compliant Yes EF-1 Specification Data Panasonic Ventilation Fan Description Ventilating fan shall be Low Noise ceiling mount type rated for continuous run.Fan shall be ENERGY STAR rated and certified by the Home Ventilating Institute (HVI).Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: •Four–pole totally enclosed condenser motor rated for continuous run. •Power Rating shall be 120 volts and 60 Hz. •Fan shall be UL listed for tub/shower enclosure when used with a GFCI branch circuit wiring. •Motor equipped with thermal–cutoff fuse. •Removable with permanently lubricated plug–in motor. Housing: •Rust proof paint,galvanized steel body. •Detachable 4"diameter duct adapter. •Built in backdraft damper. •Expandable extension bracket up to 24". •Double hanger bar system allowing for ideal positioning. Grille: •Attractive design using PP material. •Attaches directly to housing with torsion springs. Warranty: •The factory warranty shall be a minimum of 3 years limited warranty on parts. Typical Specifications: Ventilating fan shall be of the ceiling mount,ENERGY STAR rated type,with no less than 110 CFM and no more than 0.8 sone as certified by the Home Ventilating Institute (HVI)at 0.1 static pressure in inches water gauge.Power consumption shall be no greater than 30.7 watts and ENERGY STAR rated with efficiency rating of no less than 3.6 CFM/watt.The motor shall be totally enclosed,four pole condenser type engineered to run continuously.Power rating shall be 120v/60Hz.Duct diameter shall be no less than 4".Fan shall be UL and cUL Fan shall be California Title-24 compliant. listed for tub/shower enclosure when used with GFCI branch circuit wiring. FV-11VQ3 (110 CFM) Panasonic Home & Environment |One Panasonic Way |Secaucus,NJ 07094 |866-292-7292 |www.panasonic.com/building For Complete Installation Instructions Visit www.panasonic.com/building Model Quantity Comments Project: Location: Architect: Engineer: Contractor: Submitted by: Date: Specifications: FV-11VQ3 52.0"1.0.g.wsehcninierusserPcitatS 49011)MFC(emuloVriA AN8.0)senos(esioN 6.037.03)sttaw(noitpmusnoCrewoP 1.36.3/WattMFC:ycneiciffEygrenE 979018)MPR(deepS seYdetaRRATSYGRENE seYedoCQAIVetatSnotgnihsaW w (CFM)StaticPressure(inchw.g.)Fan Curve FV-11VQ3 14-1/2” or 24” 4”4” 7-7/8” 14-1/2” or 16” 13”13” 10-1/4”10-1/4” As of 11/06