Loading...
HomeMy WebLinkAboutFile Documents.971 Ute Ave.0247.2017 (10).ARBKThe City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT APPLICATION MASTER PERMIT: ______________________DATE:___________ CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 PROPERTY INFORMATION ___________________________________ _________ ___________________________ ______________ ______________ ________________________________________ __________________________________________________________________________________ ____________________________________________________________________________________________ _________________________ _______________ __________________________________ ________________________ _______________ __________________________________ PERMIT NUMBER: __________________________ CommericalMulti-FamilySingle Family Use of Building Class of Work NewAdditionAlterationRepair ________ YesNo Will there be any roof/wall penetrations? NOTICE: This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended or abandoned for a period of 180 days at any time after work is commenced. __________________ _________________ __________________ ____________________ ________________ _________________ __________ PROJECTVALUATION SQ FT OF WORK AREA UNIT SQ FT SQ FT OF LAND-SCAPE WORK SQ FT OF ROOMS WITH UTILITY WORK LOT SIZE(SQ FT) PROJECT DETAILS Mixed-Use IFFRTenant FinishDemolitionChange Order ________ ADDRESS UNIT #PARCEL ID # BLOCK TRACT OR SUBDIVISIONLOT DESCRIPTION OF WORK IN DETAIL FOR CITY USE ONLY Plan Check Permit Fee Parks Impact Energy Code REMP School Ded. Zoning (50%)Plan Check (Hourly) TDM Impact Engineering Review Zoning (Hourly)Ped. Amenity CMP (50%)Engineering (Hourly) Housing Cash in Lieu Parks Review Zoning (50%)Stormwater Utility Review CMP (50%)City Use Tax Other Electrical County Use Tax Plumbing GIS Mechanical Sanitation SUBMITTAL FEES ISSUANCE FEES __________________PLANS LOCATION _________Lot Area _________Zone District _________Deed Restricted _________Census Code _________# of Dwellings APPROVALS ISSUANCE FEES BEST CONTACTNAME CELL EMAIL OWNER NAME CELL EMAIL ____Toilets, Bidets ____Bathtub____Lavatory (Wash Basin)____Shower____Kitchen Sink (+Disposal)____Dishwasher____Laundry Bar, Utility Sink____Clothes Washer ____Floor Sink____Floor Drain____Shower____Water Heater (Pan Req)____# Gas Outlets____Water Treatment____Other_________ Fixture Counts ____Forced Air/Gravity Systems ____Wall, Suspended, or Unit Heaters ____Gas Log ____Gas Appliancew____Appliance Vents ____Heat, Refrig, Cooling, or Absorption Unit ____Boilers (includes vent) ____Air Handling Unit ____Cooling Systems____Ventilation Fans ____Range Hood ____# of Gas System Outlets ____Snowmelt System Sq Ft_________ Equipment Checklist Zoning HPC Building Fire Engineering CMP Utilities Water Stormwater Sanitation Env. Health Parks Landscape Efficiency Approved To Issue Issuance ReviewRequired Date ApprovedReviewingDepartmentReviewerInitials Call Assessor (970-920-5160) to verify NEW SQ FT Details Term DefinitionsProject Valuation: Cost of project as defined in Valuation Affadavit.Sq Ft of Work Area: Total square footage of area undergoing change or reconfiguration.Unit Sq Ft: Gross Square Footage, not FAR, of permitted unit.Lot Size: Total surveyed square footage of property.Sq Ft of Landscape Work: Square footage of disturbed exterior area.New Sq Ft: Total added square footage for additions to net livable or net leasble space.Sq Ft of Rooms with Utility Work: Total square footage, not FAR, of all rooms with plumbing work.DO YOU LIKE DOGS? August 2017 971 UTE AVENUE 273718295029 1 UTE ADDITION REPLACE EXISTING STAIRCASE, UPDATED SCOPE OF WORK RYAN DOREMUS 970-274-1421 RYAN@THUNDERBOWLARCHITECTS.COM 971 UTE KS LLC 970-925-2619 BROOKE.PETERSON@AJAX-HOLDINGS.COM 200 9/27/17 0247.2017.arbk 0085.2017.arbk TF KAEGEBEIN FINE HOMEBUILDING BRIAN WELLS 11.7.17 11/09/2017 (e) DECK OVERHANG TO REMAIN (e) WALL ASSEMBLY TO REMAIN (e) DECK STRUCTURE TO REMAIN (e) STEEL BEAM TO REMAIN (e) SOFFIT TO REMAIN (e) INTERIOR FLOORING TO REMAIN (e) 34" SHEATHING TO BE REPLACED AS NEEDED (e) FASCIA TO REMAIN. REPLACE AS NEEDED (e) WALL ASSEMBLY TO REMAIN (n) SPRAY FOAM INSULATION (n) BATT INSULATION (n) 12" DRAINAGE MAT (n) THIN SET CONCRETE, 1 8" PER 1' SLOPE AWAY FROM HOUSE (n) STONE DECKING TO MATCH EXISTING (n) CABLE RAILING SYSTEM (n) 2X2 STEEL POST (n) WOOD CAP 3"3"3'-0"2"2" (n) HOT APPLIED WATERPROOF MEMBRANE (n) FLASHING AREA IN QUESTION REGARDING LEAK (n) GYP. WALL BOARD ON CEILING NOTE: ALL SHADED AREAS ARE EXISTING CONDITIONS TO REMAIN. SCOPE OF WORK IS LIMITED TO REPLACING DAMAGED WATER PROOFING, FINISHED DECK, AND RAILING. 1 8" SLOPE Drawing Sheet / Spec Section:Scale: Date: Sketch No. - Item No.: ASI Reference.: Sketch "NOT FOR CONSTRUCTION" without ASI no. Project No.: Project Name: Sketch Name: Sketch THUNDERBOWL ARCHITECTS (a) 300 S. Spring Street, Suite 201 Aspen, CO 81611 (p) 970.710.2938 (w) www.thunderbowlarchitects.com DECK WATERPROOFING REPAIR DETAIL 01-01 ASI# 01 08/17/201717007.00 1/2" = 1'-0" 971 UTE AVENUE SPECIAL INSPECTION AND TESTING AGREEMENT To permit applicants of project requiring special inspection and\or testing per Section 1704 of the International Building Code (IBC). Project Address: __________________________________ Permit Number:______________________ BEFORE A PERMIT CAN BE ISSUED: The owner, or the engineer or architect of record, acting as the owner’s agent, shall complete two copies of this agreement and the attached Special-inspection and Testing Schedule, including the required acknowledgments. A pre-construction conference with the parties involved may be required to review the special-inspection requirements and procedures. APPROVAL OF SPECIAL INSPECTORS: Special inspectors may have no financial interest in the projects for which they provide special inspections. Special inspectors shall be approved by the building department prior to performing any duties. Special inspectors shall submit their qualifications and are subject to personal interviews for pre-qualification. Special inspectors shall display approved identification, as stipulated by the building official, when performing the function of special inspector. Special inspection and testing shall meet the minimum requirements of the International Building Code Section 1704. The following conditions are also applicable: A. Duties and Responsibilities of the Special Inspector 1. Signify presence at job site. Special inspectors should notify contractor personnel of their presence and responsibilities at the job site. If required by the building official, they shall sign in on the appropriate form posted with the building permit. Observe assigned work. The special inspector shall observe assigned work for conformance with the building department approved (stamped) design drawings, specifications, and applicable workmanship provisions of the International Building Code. Architect\engineer-reviewed shop drawings may be used only as an aid to inspection. For continuous special-inspection, the special inspector shall be on site at all times observing the work requiring special inspection. Periodic inspections, if any, must have prior approval based on a separate written plan reviewed and approved by the building department and the engineer or architect of record. 3. Report nonconforming items. The special inspector shall bring nonconforming items to the immediate attention of the contractor and note all such items in the daily report. If any item is not resolved in a timely manner or is about to be incorporated in the work, the special inspector shall immediately notify the building department by telephone or in person, notify the engineer or architect, and post a discrepancy notice. Provide timely reports. The special inspector shall complete written inspection reports for each inspection visit and provide the reports on a timely basis determined by the building official. The special inspector or inspection agency shall furnish these reports directly to the building official, engineer or architect of record, and others as designated. [IBC Sec. 1704.1.2] These reports should be organized on a daily format and may be submitted weekly at the option of the building official. These reports should include: a. Description of daily inspections and tests made with applicable locations, b. Listing of nonconforming items, c. Report on how nonconforming items were resolved or unresolved as applicable, d. Itemized changes authorized by the architect, engineer, and building official if not included in nonconforming items. 2. 4. 1 5. Provide Final Inspection Report. The special inspector shall submit a written final report documenting required special inspections and correction of any discrepancies noted in the inspections prior to the final building inspection. B. Owner Responsibilities. The project owner, the engineer or architect or record, or an agent of the owner is responsible for employing special-inspection services. The special inspector\agency shall not be in the employ of the contractor, subcontractor or material supplier. [IBC Sec 1704.1] In case of an owner\contractor, the special inspector\agency shall be employed as specified by the building official. C. Engineer or Architect of Record Responsibilities 1. Prepare special inspection program. The engineer or architect of record shall list the items for which special inspection is required; and shall indicate any items for which the IBC or the building official approves periodic inspection and the frequency of such inspections. Respond to field discrepancies. The engineer or architect of record shall respond to uncorrected field discrepancies in design, material, or workmanship observed by the special inspector. Review shop drawings and submit design changes. The engineer or architect of record shall acknowledge and review for conformance with the construction drawings those shop drawings that may detail structural information, shall submit to the building official and to the special-inspection agency written documentation of any verbally authorized deviations from the approved construction documents, and shall submit revised documents for building official approval as required. 2. 3. D. Contractor Responsibilities 1. Notify the special inspector. The contractor is responsible for notifying the special inspector or agency regarding individual inspections for items listed on the attached schedule and as noted on the building department approved plans. Adequate notice shall be provided so the special inspector has time to become familiar with the project. Provide access to approved plans. The contractor is responsible for providing the special inspector access to approved plans. Retain special inspection records. Upon request, the contractor is also responsible for retaining, at the job site, all special inspection records completed by the special inspector. 2. 3. E. Inspection of Fabricators 1. Fabrication of structural assemblies and members. Where fabrication of structural load-bearing members and assemblies is being performed on the premises of a fabricator’s shop, IBC Section 1704.2 shall require special inspection of the fabricated items. Fabrication and implementation procedures. The special inspector shall verify that the fabricator maintains detailed fabrication and quality control procedures that provide a basis for inspection control of the workmanship and the fabricator’s ability to conform to approved construction documents and reference standards. The special inspector shall review the procedures for completeness and adequacy relative to code requirements for fabricator’s scope of work. 2. F. Approved Fabricator Responsibilities 1. Fabrication exempt inspections. Special inspections are not required where work is done on the premise of a fabricator registered and approved to perform such work without special inspection. 2 REFERENCES FROM 2009 IRC CV/CS = crawl space ventilation required, sec. R408.1 Access required, R408.4 EE = emergency escape required sec R310.1 EU = enclosed usable space under stairs shall be ½” Gyp, sec R302.7 G/D = garage/dwelling separation, sec R302.5 and R302.6 STC = Sound transmission class not less than 45 at dwelling separations, app K RV = roof and rafter ventilation required, R806.1 A = attic access 22” x 30”, 30” headroom above, R807.1 SA = smoke alarms installed to NFPA 72 requirements, sec R314 CO = carbon monoxide detector per City Ordinance 41 series 2008 SG = safety glazing required, sec R308.4 V = bathroom mechanical ventilation req. per City Ordinance 31 series 2011 GR = guardrails, 36” min ht, 4” max opening; req at 30” drop any point w/in 36” horizontally, sec R312 HR = handrails 34”-38” ht, sec R311.7.7 SI = stairway illumination, sec R303.6 PD = protect against decay, sec R317 REFERENCES FROM 2009 IMC DE = clothes dryer exhaust, sec 504. Makeup air req’d if over 200 CFM AS = access and service space for maintenance req’d, sec 306 MA = make up air required if hood exhausts greater than 400 CFM, sec 505.2 ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes, 501.2.1 IT= intake openings 10’ from lot line & contaminant sources (vents, streets), 401.4 D = fasten and seal all ductwork per 603.9 REFERENCES FROM 2009 IFGC DV = direct vent req’d, sec 303.3 CA = combustion air not taken from bedrooms, bathrooms or storage sec 303.3 OD = outdoor appliances must be listed for outdoor use, sec 303.6 REFERENCES FROM 2009 IECC F = new or replacement glazing shall not exceed 0.35 U-Value, NFRC label required, sec 402.3.6 L = 50% of lamps in permanently installed lights must be high efficacy, sec 404.1 SE = All exterior joints, cracks, holes to be caulked, gasketed, sealed, sec 402.4 REFERENCES FROM 2011 NEC EP = electric panel ‘happy space’ 30”x36”x78”, not in storage, sec 110.26 11/14/2017 tonyf 971 UTE AVE 0085.2017.ARBK DAM 11 / 16/17 0247.2017.ARBGK CIVIL ENGINEER: - CONTACT: - - COL. C.O. CEILING HEIGHT A.F.F.+13'-11" PROJECT ADDRESS: PARCEL ID: FIRE SPRINKLER SYSTEM INSTALLED: APPLICABLE CODES: ·2015 IRC (International Residential Code) Chapters 1-10 ·2015 IRC appendixes: ·Manufactured homes, F: Radon, J: Existing Buildings & Structures, H:Patio Covers, K: Sound Transmission. ·2015 IPC (International Plumbing Code) ·2015 IMC (International Mechanical Code) ·2015 IFGC (International Fuel Gas Code) ·2015 IECC (International Energy Conservation Code) - Prescriptive Path ·2015 IFC (International Fire Code) ·2014 NEC (National Electrical Code) 971 Ute Aveune, Aspen CO 81611 273718295029 NO R-15 3,682.79 sq ft EXISTING, 3,682.79 sq ft PROPOSED (NO CHANGE) Residential Front - 25', Side and Rear - 10' ZONING: F.A.R. PERMITTED USE: SETBACKS: Tread Terrazzo Thick Tempered TEL. T.C. T.B. T. THK. T.M.E. T.O.C. T.&G. TER. TEMP. To Match Existing Top of Concrete Towel Bar Top of Curb Telephone Tongue & Groove Typical Varies UnfinishedUNF. V.C.T. VAR. U.O.N. UNEXC. U.B.C. T.O. PLY T.O.W. TYP. Veneer Vertical Vestibule Volume Wood West With V.I.F. W.C. WD. W.H. W. W/ V.G.D.F. VOL. VERT. VEST. VEN. Wall Covering Water Heater Vertical Grain Douglas Fir Verify in Field Vinyl Composition Tile Top of Plywood Top of Wall Uniform Building Code Unexcavated Unless Otherwise Noted Top of PlateT.O.P. Wainscot Weight W.P. WW. WR. WT. W.S.P. W.P.M. WSCT. Welded Wire Work Point or Waterproofing Waterproof Membrane Wet Standpipe Water Resistant WithoutW/O REQ. RESIL. REINF. REG. REV. RWD. REMOV. R.O. RM. RET. Rough Opening Redwood Required Removable Room Resilient Retaining Reinforced Register Mounted Mullion Nominal North Number New Not to Scale Miscellaneous Not in Contract S.C.D. S.D. S. S.A.F.F SEP. SHT. S.H. SECT. S.E.D. SCHED. Separation Sprinkler Head Sheet See Civil Drawings Soap Dispenser/Dish See Electrical Drawings Storm Drain, Schedule Section Self-Adhesive Flexible Flashing South S.G.D. S.L.D. SHTG. S.C.D. SL. SIM. S.P.D. SPEC. S.M.D. S.S. SQ. S.LT.D. Stainless Steel Square See Lighting Drawings See Garage Drawings See Plumbing Drawings See Civil Drawings Sheathing Sliding Similar Opposite Opening On Center Overall Plaster Plywood Perimeter Plate Plastic Laminate Outside Diameter (Dim.) Point Paint Quarry Tile Partition Painted Paper Towel Receptacle Per Square Inch Pressure Treated Post Tensioned Paper Towel Dispenser Panel MUL. MISC. MTD. NOM. N.T.S. N.I.C. N. (N) Hardware Hardwood Hanger Height Horizontal Handrail Hour Hot Water Heater Hollow Metal HGT. HDW. HDWD. HGR. H.W.H. HORIZ. HR. H.R. H.M. Floor Drain Fire Extinguisher Cabinet Flat Bar Fixture Floor Srew Finish Flat Head Wood Screw Flat Head Machine OPP. O.A. O.C. O.D. PLAS. PL. Insulation Interior Inch Kitchen Joist Joint Janitor Junction Box Intermediate P.S.I. PNT. PT. P.T. P.T.R. P.T.D. PTN. Q.T. PTD. Laminate Lavatory Pound Linear Light Maintain Material Maximum Machine PNL. INTER. IN. INSUL. INT. KIT. JST. JB JT. JAN. Fluorescent Face of Finish Face of Plywood Face of Stud Footing Furring Future Frame Foot or Feet Fireproof Face of Concrete LB. LIN. LT. LAM. LAV. MAINT. MAT. MAX. MACH. General Gauge Gas Outlet Galvanized Ground Grade Glass Interrupt Ground Fault Galvanized Sheet Garbage Disposal Flashing Inside DiameterI.D. ABBREVIATIONS P.LAM. PLYWD. PERIM. OPNG. NO. or # STOR. STRL. STD. STL. S.V. SYS. SYM. S.W. System Steel Structural Sheet Vinyl Shear Wall Symmetrical Storage StandardReturn Air Recessed Radius Riser Reference Reflected Refrigerator REC. RAD. R.A. R. REFR. REFL. REF. Overlay Mechanical Membrane Minimum Metal Machine Bolt Medicine Cabinet Medium Density Manufacturer M.D.O. MEMB. MECH. M.B. M.C. MIN. MTL. MFR. Gypsum Handicapped Hose Bibb Hollow Core or Header Head Hardboard Metal S.S.D. See Structural Drawing Specification or Special See Landscape Drawings See Mechanical Drawings Revision/Revised/Reversed F.E. F.B. F.D. FIXT. FLR. F.H.W.S. FIN. F.H.M.S. CONSTR. CONN. COND. CONC. CTR. C.W. C.T. CONTR. CLOS. CONT. Center Cold Water Contractor Closet Ceramic Tile Condition Connection Construction Continuous Concrete F.O. Ply F.O.S. FLUOR. F.O.C. F.O.F. FURR. FUT. FTG. FR. FT. F.P.R.F. GALV. G.D. GEN. G. GA. GND. G.S.M. GR. GL. G.F.I. DIA. DIM. DBL. DET. D.F. DWG. DWR. D.W. DN. DR. DISP. E.J. EA. (E) E.I.F.S. E.O.S. ENCL. E.P.B. ELEC. EMER. EL. Dishwasher Edge of Slab Electrical Panel Board Enclosure Exterior Insulation & Elevation Electrical Emergency Existing Finish System Expansion Joint Each Drawing Drawer Drinking Fountain Dispenser Down Door Double Diameter Dimension Detail FLASH. At@ & < A.C. # 0 ACOUS. ALUM. ALT. ADJ. AGGR. ADJAC. BITUM. BD. ARCH. ASPH. APPROX. BM. B.O. BOT BLKG. BLK. C.B. CEM. CER. B.P. BTWN. BLDG. A.D. Catch Basin Cement Ceramic Beam Bottom of Building Paper Between Bottom Building Blocking Bituminous Board Block Diameter or Round Air Conditioning or Asphaltic Concrete Aluminum Approximate Architectural Asphalt Alternate Acoustical Area Drain Adjustable Aggregate Adjacent Pound or Number Angle And H.B. H.C. GYP. HDR. HDBD. HD. EXP. EXT. EXIST. EQUIP. F.A.U. F.A. Forced Air Unit Fire Alarm Equipment Existing Expansion Exterior CLKG. C.M.U. CLR. CLG. CNTR. Column Concrete Masonry Caulking Clean-Out Counter Unit Clear Ceiling C.J. Control Joint EqualEQ. PROJECT DIRECTORYVICINITY PLAN CONTACT: Ryan Doremus STRUCTURAL ENGINEER: LANDSCAPE DESIGN: OWNER/CLIENT: ARCHITECT: Aspen, CO 81611 Thunderbowl Architects 300 Spring St. Suite 201 Email: ryan@thunderbowlarchitects.com Ajax Holdings SHEET NUMBER INTERIOR ELEVATION NUMBERS SYMBOLS 3 A6.1 1 A4.3 DOOR SYMBOL14 1A A 3 A6.1 DETAIL NUMBER SHEET NUMBER WINDOW SYMBOL PARTITION TYPE SHEET NUMBER BUILDING SECTION NUMBER SHEET NUMBER ENLARGED DETAIL NUMBER HOSE BIBB REVISION COLOR FINISH MATERIAL HB JB XX X 1 (N)/(E) CONSTRUCTION JUNCTION BOX Aspen, Colorado 971 UTE AVENUE GENERAL NOTES PROJECT STATISTICS TYPE: OCCUPANCY: OVERALL PROJECT HEIGHT AND AREA: PROJECT SUMMARY: Type V - Non-rated Type R-3 Maximum Height N/A - Area N/A INTERIOR REMODEL OF EXISTING BATHROOMS AND UPDATING KITCHEN CABINETRY AND PLUMBING FIXTURES. - - CONTACT: - CONTRACTOR A5.2 1 2 3 4 FOR ALL DRAWINGS EXCEPT DETAILS DIMENSIONING KEY TICK LEADER DENOTES DIMENSION TO FRAMING DOT LEADER DENOTES DIMENSION TO GRIDLINE/< 2'-2"3'-6" ARROW LEADER DENOTES DIMENSION TO FINISH 3'-5" CHANGE ORDER #1 SEPTEMBER 5TH, 2017 SITE 971 UTE AVENUE ASPEN, COLORADO The work included under this contract consists of all labor, materials, transportation, tools and equipment necessary for the construction of the project leaving all work ready for use. The construction documents are the property of Thunderbowl Architects Inc and its Consultants and are to be used as instruments of service for construction of this project only. Use for any other purpose, without authorization, is not allowed. The plans indicate the general extent of new construction necessary for the work, but are not intended to be all-inclusive. All demolition and all new work necessary to allow for a finished job in accordance with the intention of the drawing is included regardless of whether shown on the drawings or mentioned in the notes. Any errors, omissions or conflicts found in the various parts of the construction documents shall be brought to the attention of the Architect and the Owner for clarification before proceeding with the work. The General Contractor shall maintain a current and complete set of the construction documents on the job site during all phases of construction for use of all the trades and shall provide all the subcontractors with current and complete construction documents as required including specifications and architectural supplementary instructions. The General Contractor shall verify and assume responsibility for all dimensions and site conditions. The General Contractor shall inspect the existing premises and take note of existing conditions prior to submitting prices. No claim shall be allowed for difficulties encountered which could have reasonably been inferred from such an examination. Written dimensions take precedence. Do not scale drawings. See SYMBOLS area of this sheet for dimension standards. All dimensions noted "verify" and "V.I.F." are to be checked by Contractor prior to construction. Immediately report any variances to the Architect for resolution, then coordinate resolution w/ all work of all trades. Coordinate all work with existing conditions, including but not limited to: irrigation pipes, electrical conduit, water lines, gas lines, drainage lines, etc. Notify Architect immediately of any conflicts. Provide adequate temporary support as necessary to assure the structural value or integrity of the building. Protect all existing building and site conditions to remain, including walls, cabinets, finishes, trees and shrubs, paving, etc. Details shown are typical. Similar details apply in similar conditions. Verify all architectural details with structural, civil, landscape and design/build drawings before ordering or installation of any work. All changes in floor materials occur at centerline of door or framed opening unless otherwise indicated on the drawings. Install all fixtures, equipment and materials per manufacturer's recommendations. Verify clearances for flues, vents, chases, soffits, fixtures, etc. before any construction, ordering of, or installation of any items of work. Sealant, caulking and flashing, etc. locations shown on drawings are not intended to be inclusive. Follow manufacturer's installation recommendations and standard industry and building practices. The General Contractor shall remove all rubbish and waste materials of all subcontractors and trades on a regular basis, and shall exercise a strict control over job cleaning to prevent any direct debris or dust from affecting, in any way, finished areas in or outside job site. Contractor shall leave premises and all affected areas clean and orderly, ready for occupancy. This includes cleaning of all glass (inside and outside) and frames, both new and existing. Any survey monuments within the area of construction shall be preserved or reset by a registered civil engineer or a licensed land surveyor. Verify all finish materials with the Architect and the Owner prior to installation. On site mock-ups of building assemblies, finish assemblies, paint and/or stain samples, etc. may be required for approval. Contractor to coordinate utilities shown on architectural drawings with electrical, plumbing, mechanical, and any other consultant drawings. Contractor to coordinate all the trades. Structural observation shall be required by the Engineer for structural conformance to the approved plans. It is the General Contractors responsibility to obtain inspections and special inspections as necessary. All construction to provide a waterproof, weather tight building. Contractor should flash and caulk as necessary to achieve this requirement. S. South Oddo Engineering, Inc. CONTACT: Bob Oddo - - Kaegebein Fine Homebuilding CONTACT: Nate Kaegebein - - 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. SHEET INDEX NOT INCLUDED IN THIS SET INCLUDED IN THIS SET DATES ISSUEDSHEETTITLE DELETED FROM SET - MECHANICAL DESIGN: - - CONTACT: -Tel: (XXX) XXX-XXXX Email: Tel: (XXX) XXX-XXXX Email: Tel: (XXX) XXX-XXXX Email: Tel: (970) 945-1006 Email: bob@oddogws.com Tel: (970) 379-6228 Email: natekaegebein@kfhomebuilding.com Tel: (970) 274-1421 PERMIT SET04/06/2017G0.00 COVER Z-001 FLOOR AREA CALCULATIONS D-101 D-102 D-103 EXISTING/DEMO UPPER LEVEL FLOOR PLAN A-101 PROPOSED LOWER LEVEL FLOOR PLAN A-102 PROPOSED MAIN LEVEL FLOOR PLAN A-103 PROPOSED UPPER LEVEL FLOOR PLAN EXISTING/DEMO MAIN LEVEL FLOOR PLAN EXISTING/DEMO LOWER LEVEL FLOOR PLAN D-104 EXISTING/DEMO LOWER LEVEL RCP D-105 EXISTING/DEMO MAIN LEVEL RCP D-106 EXISTING/DEMO UPPER LEVEL RCP A-104 PROPOSED LOWER LEVEL RCP A-105 PROPOSED MAIN LEVEL RCP A-106 PROPOSED UPPER LEVEL RCP Tel: (970) 274-1421 CONTACT: Ryan Doremus (Thunderbowl Architects) Aspen, CO 81611 300 Spring St. Suite 201 Email: ryan@thunderbowlarchitects.com A-401 PROPOSED STAIR DETAILS CHANGE ORDER #109/05/2017S1.1 STRUCTURAL DETAILS PROJECT SCALE GENERAL INFORMATION SHEET 17007.00 G0.00 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 9/27/17 11/09/2017 11/14/2017 tonyf 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"DECK 202.34 sq ft FLOOR AREA 1,696.14.35 sq ft 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"FLOOR AREA 1,307.35 sq ft GARAGE 410.00 sq ft 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"FLOOR AREA 1,763.10 sq ft 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"FLOOR AREA 1,763.10 sq ft 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"FLOOR AREA 1,307.35 sq ft GARAGE 410.00 sq ft 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"W/D W/D DECK 202.34 sq ft FLOOR AREA 1,696.14.35 sq ft PROJECT SCALE FLOOR AREA CALCULATIONS 1/8" = 1'-0" 17007.00 Z-001 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1NEXISTING LOWER LEVEL 1/8" = 1'-0" 1 Z-001 0 4 8 16 Scale: 1/8" = 1'-0" EXISTING MAIN LEVEL 1/8" = 1'-0" 2 Z-001 EXISTING UPPER LEVEL 1/8" = 1'-0" 3 Z-001 PROPOSED LOWER LEVEL 1/8" = 1'-0" 4 Z-001 PROPOSED MAIN LEVEL 1/8" = 1'-0" 5 Z-001 PROPOSED UPPER LEVEL 1/8" = 1'-0" 6 Z-001 N0 4 8 16 Scale: 1/8" = 1'-0"N0 4 8 16 Scale: 1/8" = 1'-0"N0 4 8 16 Scale: 1/8" = 1'-0"N0 4 8 16 Scale: 1/8" = 1'-0"N0 4 8 16 Scale: 1/8" = 1'-0" DECK AREA GARAGE AREA FLOOR AREA PROPOSED FLOOR AREA CALCULATIONS FLOOR AREA LEGEND EXISTING FLOOR AREA CALCULATIONS LOWER LEVEL 1,763.10 sq. ft. MAIN LEVEL 1,307.35 sq. ft. GARAGE 410.00 sq. ft. DECKS/PORCH 202.34 sq. ft. TOTAL 3,682.79 sq. ft. LOWER LEVEL 1,763.10 sq. ft. MAIN LEVEL 1,307.35 sq. ft. GARAGE 410.00 sq. ft. DECKS/PORCH 202.34 sq. ft. TOTAL 3,682.79 sq. ft. 9/27/17 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"UP BED 101 CARPET ADU BED 103 CARPET ADU BATH 102 STONE ADU KITCHEN 104 STONE CLOSET 113 CARPET ADU CLOSET 105 CARPET BATH 111 STONE MEDIA ROOM 107 CARPET CRAWL SPACE 108 CONCRETE MECH. ROOM 109 CONCRETE LAUNDRY 110 STONE BUNK ROOM 112 CARPET ADU STAIR 106 CONCRETE UP CLOSET 115 CARPET BATH 114 STONE T.O. SLAB EL. = 89'-0 3/4" V.I.F. REF BUILT IN SUMP PUMP LOCATION W D REPLACE EXISTING FIXTURES AND CABINETS EXISTING MECH. EQUIPMENT TO REMAIN AREAS OF WORK AREA OF WORK WALLS AND CEILING SEPARATING ADU FROM REST OF HOUSE TO BE 1 HR FIRE RATED WITH STC OF AT LEAST 50. SEE ATTACHED LISTED WALL ASSEMBLY, GA FILE NO. WP 3261 EXISTING ADU KITCHEN APPLIANCES TO REMAIN REPLACE EXISTING ADU BATH FIXTURES AND CABINETS EXISTING EXISTING W/D TO BE REPLACED 1 1 PROJECT SCALE LOWER LEVEL DEMOLITION PLAN 1/4" = 1'-0" 17007.00 D-101 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 LOWER LEVEL DEMOLITION PLAN 1/4" = 1'-0" 1 D-101 0 2 4 8 Scale: 1/4" = 1'-0"NDEMOLITION NOTES 1.FURNISH EQUIPMENT AND PERFORM LABOR REQUIRED TO EXECUTE THE CONTRACT DOCUMENTS. 2.PROTECT EXISTING WORK TO REMAIN INCLUDING DUST CONTROL. 3.THE DRAWINGS DO NOT NECESSARILY INDICATE THE FULL EXTENT OF THE WORK TO BE PERFORMED. INSPECT THE EXISTING CONSTRUCTION CAREFULLY TO DETERMINE THE FULL EXTENT OF WORK TO BE PERFORMED AND THE CHALLENGES INVOLVED. 4.DO NOT ALLOWED DEMOLISHED DEBRIS TO ACCUMULATE ON SITE BEYOND A REASONABLE AMOUNT. MAINTAIN PROGRESSIVE DISPOSE OF DEBRIS IN A LEGAL MANNER. 5.REMOVAL OF ALL HAZARDOUS MATERIALS IS THE RESPONSIBILITY OF THE OWNER. SHOULD THE CONTRACTOR ENCOUNTER ANY HAZARDOUS MATERIALS WHILE EXECUTING DEMOLITION, THEY SHOULD CONTACT THE OWNER IMMEDIATELY. 6.VERIFY ALL SALVAGING REQUIREMENTS WITH THE OWNER PRIOR TO DEMOLITION. 7.NOTIFY OWNER 48 HOURS PRIOR TO ANY UTILITY SERVICE DISRUPTION. 8.COORDINATE EXTENT OF ALL STRUCTURAL DEMOLITION WITH THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN AND IMPLEMENTATION OF TEMPORARY SHORING AND BRACING AS REQUIRED. 9.VERIFY EXTENT OF WALL AND ROOF REMOVAL WITH STRUCTURAL ENGINEER. 10.PRIOR TO COMMENCEMENT OF DEMOLITION, EXTENT OF STRUCTURE AND/OR FINISH TO BE REMOVED MUST BE VERIFIED WITH BOTH THE OWNER AND ARCHITECT. 11.PROVIDE NECESSARY EROSION CONTROL PER LANDSCAPING OR CIVIL DRAWINGS. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. (E) CONST. TO BE REMOVED OR NEW MASONRY WALL NEW CONSTRUCTION EXISTING CONSTRUCTION AREA OF WORK AREA OF WORK LOWER LEVEL:263 sq ft TOTAL:1,548 sq ft UPPER LEVEL:935 sq ft MAIN LEVEL:350 sq ft 9/27/17 tonyf 11/14/2017 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"F.D.F.D. DN DN UP DN DN STAIR 203 WOOD STAIR 106 CONCRETE MUD ROOM 206 STONE CLOSET 205 STONE ENTRY 204 STONE GARAGE 207 CONCRETE MSTR CLOSET 208 CARPET MSTR BATH 201 STONE MASTER BED 202 CARPET T.O. PLY EL. = 99'-7 7/8" V.I.F. T.O. PLY EL. = 100'-0" V.I.F. T.O. SLAB EL. = 99'-7 7/8" V.I.F. GAS FIREPLACE AREA OF WORK BUILT IN OPEN TO ABOVE REPLACE EXISTING BATHROOM FIXTURES AREA OF WORK 1 1 PROJECT SCALE MAIN LEVEL DEMOLITION PLAN 1/4" = 1'-0" 17007.00 D-102 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 MAIN LEVEL DEMOLITION PLAN 1/4" = 1'-0" 1 D-102 0 2 4 8 Scale: 1/4" = 1'-0"NDEMOLITION NOTES 1.FURNISH EQUIPMENT AND PERFORM LABOR REQUIRED TO EXECUTE THE CONTRACT DOCUMENTS. 2.PROTECT EXISTING WORK TO REMAIN INCLUDING DUST CONTROL. 3.THE DRAWINGS DO NOT NECESSARILY INDICATE THE FULL EXTENT OF THE WORK TO BE PERFORMED. INSPECT THE EXISTING CONSTRUCTION CAREFULLY TO DETERMINE THE FULL EXTENT OF WORK TO BE PERFORMED AND THE CHALLENGES INVOLVED. 4.DO NOT ALLOWED DEMOLISHED DEBRIS TO ACCUMULATE ON SITE BEYOND A REASONABLE AMOUNT. MAINTAIN PROGRESSIVE DISPOSE OF DEBRIS IN A LEGAL MANNER. 5.REMOVAL OF ALL HAZARDOUS MATERIALS IS THE RESPONSIBILITY OF THE OWNER. SHOULD THE CONTRACTOR ENCOUNTER ANY HAZARDOUS MATERIALS WHILE EXECUTING DEMOLITION, THEY SHOULD CONTACT THE OWNER IMMEDIATELY. 6.VERIFY ALL SALVAGING REQUIREMENTS WITH THE OWNER PRIOR TO DEMOLITION. 7.NOTIFY OWNER 48 HOURS PRIOR TO ANY UTILITY SERVICE DISRUPTION. 8.COORDINATE EXTENT OF ALL STRUCTURAL DEMOLITION WITH THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN AND IMPLEMENTATION OF TEMPORARY SHORING AND BRACING AS REQUIRED. 9.VERIFY EXTENT OF WALL AND ROOF REMOVAL WITH STRUCTURAL ENGINEER. 10.PRIOR TO COMMENCEMENT OF DEMOLITION, EXTENT OF STRUCTURE AND/OR FINISH TO BE REMOVED MUST BE VERIFIED WITH BOTH THE OWNER AND ARCHITECT. 11.PROVIDE NECESSARY EROSION CONTROL PER LANDSCAPING OR CIVIL DRAWINGS. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. (E) CONST. TO BE REMOVED OR NEW MASONRY WALL NEW CONSTRUCTION EXISTING CONSTRUCTION AREA OF WORK AREA OF WORK LOWER LEVEL:263 sq ft TOTAL:1,548 sq ft UPPER LEVEL:935 sq ft MAIN LEVEL:350 sq ft 9/27/17 11/14/2017 tonyf 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"KITCHEN 308 WOOD LIVING 303 WOOD DINING 301 WOOD BED/OFFICE 306 WOOD PANTRY 307 WOOD BATH 304 WOOD STAIR 203 WOOD DECK 302 EXISTING STONE OPEN TO BELOW DN CLOSET 305 WOOD DW REF. GAS FIREPLACE T.O. PLY EL. = 110'-0" V.I.F. AREA OF WORK ROOF BELOW ROOF BELOW ROOF BELOW EXISTING RANGE AND HOOD TO REMAIN REPLACE BATHROOM FIXTURES T.O. PLY EL. = 109'-7 3/8" V.I.F. AREA OF WORK AREA OF WORK AREA OF WORK 11 1 DECK REPLACEMENT SUBMITTED AS ADDENDUM #1 08/17/2017 PROJECT SCALE UPPER LEVEL DEMOLITION PLAN 1/4" = 1'-0" 17007.00 D-103 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 UPPER LEVEL DEMOLITION PLAN 1/4" = 1'-0" 1 D-103 0 2 4 8 Scale: 1/4" = 1'-0"NDEMOLITION NOTES 1.FURNISH EQUIPMENT AND PERFORM LABOR REQUIRED TO EXECUTE THE CONTRACT DOCUMENTS. 2.PROTECT EXISTING WORK TO REMAIN INCLUDING DUST CONTROL. 3.THE DRAWINGS DO NOT NECESSARILY INDICATE THE FULL EXTENT OF THE WORK TO BE PERFORMED. INSPECT THE EXISTING CONSTRUCTION CAREFULLY TO DETERMINE THE FULL EXTENT OF WORK TO BE PERFORMED AND THE CHALLENGES INVOLVED. 4.DO NOT ALLOWED DEMOLISHED DEBRIS TO ACCUMULATE ON SITE BEYOND A REASONABLE AMOUNT. MAINTAIN PROGRESSIVE DISPOSE OF DEBRIS IN A LEGAL MANNER. 5.REMOVAL OF ALL HAZARDOUS MATERIALS IS THE RESPONSIBILITY OF THE OWNER. SHOULD THE CONTRACTOR ENCOUNTER ANY HAZARDOUS MATERIALS WHILE EXECUTING DEMOLITION, THEY SHOULD CONTACT THE OWNER IMMEDIATELY. 6.VERIFY ALL SALVAGING REQUIREMENTS WITH THE OWNER PRIOR TO DEMOLITION. 7.NOTIFY OWNER 48 HOURS PRIOR TO ANY UTILITY SERVICE DISRUPTION. 8.COORDINATE EXTENT OF ALL STRUCTURAL DEMOLITION WITH THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN AND IMPLEMENTATION OF TEMPORARY SHORING AND BRACING AS REQUIRED. 9.VERIFY EXTENT OF WALL AND ROOF REMOVAL WITH STRUCTURAL ENGINEER. 10.PRIOR TO COMMENCEMENT OF DEMOLITION, EXTENT OF STRUCTURE AND/OR FINISH TO BE REMOVED MUST BE VERIFIED WITH BOTH THE OWNER AND ARCHITECT. 11.PROVIDE NECESSARY EROSION CONTROL PER LANDSCAPING OR CIVIL DRAWINGS. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. (E) CONST. TO BE REMOVED OR NEW MASONRY WALL NEW CONSTRUCTION EXISTING CONSTRUCTION AREA OF WORK AREA OF WORK LOWER LEVEL:263 sq ft TOTAL:1,548 sq ft UPPER LEVEL:935 sq ft MAIN LEVEL:350 sq ft 9/27/17 11/14/2017 tonyf 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"F F F S.D. S.D. S.D. S.D. S.D. S.D. WR WR WR WR WRWR BED 101 ADU BED 103 ADU BATH 102 ADU KITCHEN 104 CLOSET 113 ADU CLOSET 105 BATH 111 MEDIA ROOM 107 CRAWL SPACE 108 MECH. ROOM 109 LAUNDRY 110 BUNK ROOM 112 ADU STAIR 106 CLOSET 115 BATH 114 1 PROJECT SCALE EXISTING LOWER LEVEL RCP 1/4" = 1'-0" 17007.00 D-104 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 EXISTING LOWER LEVEL RCP 1/4" = 1'-0" 1 D-104 LEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES LARGE PENDANT LIGHT FIXTURE F SDCO 8'-0" WALL MOUNTED LIGHT FIXTURE WATER RATED LIGHT FIXTURE EXHAUST FAN SPEAKER CEILING/SOFFIT HEIGHT SYMBOL RECESSED DOWNLIGHT FLORESCENT LIGHT FIXTURE WR 1.ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. 2.VERIFY IN FIELD ALL EXISTING DIMENSIONS. 3.SEE INTERIOR ELEVATIONS FOR LOCATIONS OF SCONCES, TYP. 4.PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. 5.ALL LIGHTING TO MEET 2009 IECC LIGHTING REQUIREMENTS. 6.ALL TIMBER WORK THAT IS TO REMAIN WILL BE SANDED AND RE-FINISHED. VERIFY FINISH WITH INTERIORS. CEILING MOUNTED SMOKE / CARBON MONOXIDE DETECTOR W/ BATTERY BACKUP SP 0 2 4 8 Scale: 1/4" = 1'-0"N9/27/17 11/14/2017 tonyf 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"S.D. S.D. F WR WR STAIR 203 STAIR 106 MUD ROOM 206 CLOSET 205 ENTRY 204 GARAGE 207 MSTR CLOSET 208 MSTR BATH 201 MASTER BED 202 OPEN TO ABOVE 1 PROJECT SCALE EXISTING MAIN LEVEL RCP 1/4" = 1'-0" 17007.00 D-105 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 EXISTING MAIN LEVEL RCP 1/4" = 1'-0" 1 D-105 LEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES LARGE PENDANT LIGHT FIXTURE F SDCO 8'-0" WALL MOUNTED LIGHT FIXTURE WATER RATED LIGHT FIXTURE EXHAUST FAN SPEAKER CEILING/SOFFIT HEIGHT SYMBOL RECESSED DOWNLIGHT FLORESCENT LIGHT FIXTURE WR 1.ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. 2.VERIFY IN FIELD ALL EXISTING DIMENSIONS. 3.SEE INTERIOR ELEVATIONS FOR LOCATIONS OF SCONCES, TYP. 4.PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. 5.ALL LIGHTING TO MEET 2009 IECC LIGHTING REQUIREMENTS. 6.ALL TIMBER WORK THAT IS TO REMAIN WILL BE SANDED AND RE-FINISHED. VERIFY FINISH WITH INTERIORS. CEILING MOUNTED SMOKE / CARBON MONOXIDE DETECTOR W/ BATTERY BACKUP SP 0 2 4 8 Scale: 1/4" = 1'-0"N9/27/17 11/14/2017 tonyf 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"S.D. S.D. SP SP SP SP SP SP F KITCHEN 308 LIVING 303 DINING 301 BED/OFFICE 306 PANTRY 307 BATH 304 STAIR 203 DECK 302 CLOSET 305 SKYLIGHT BEAM BEAM BEAM RANGE HOOD SLOPESLOPESLOPESLOPESLOPE SLOPESLOPE SLOPESLOPESLOPESLOPESLOPE SLOPESLOPE SLOPE SLOPESLOPE1 1 PROJECT SCALE EXISTING UPPER LEVEL RCP 1/4" = 1'-0" 17007.00 D-106 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 EXISTING UPPER LEVEL RCP 1/4" = 1'-0" 1 D-106 0 2 4 8 Scale: 1/4" = 1'-0"NLEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES LARGE PENDANT LIGHT FIXTURE F SDCO 8'-0" WALL MOUNTED LIGHT FIXTURE WATER RATED LIGHT FIXTURE EXHAUST FAN SPEAKER CEILING/SOFFIT HEIGHT SYMBOL RECESSED DOWNLIGHT FLORESCENT LIGHT FIXTURE WR 1.ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. 2.VERIFY IN FIELD ALL EXISTING DIMENSIONS. 3.SEE INTERIOR ELEVATIONS FOR LOCATIONS OF SCONCES, TYP. 4.PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. 5.ALL LIGHTING TO MEET 2009 IECC LIGHTING REQUIREMENTS. 6.ALL TIMBER WORK THAT IS TO REMAIN WILL BE SANDED AND RE-FINISHED. VERIFY FINISH WITH INTERIORS. CEILING MOUNTED SMOKE / CARBON MONOXIDE DETECTOR W/ BATTERY BACKUP SP 9/27/17 11/14/2017 tonyf 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"W D UP BED 101 CARPET ADU BED 103 WOOD ADU BATH 102 TILE ADU KITCHEN 104 TILE CLOSET 113 CARPET ADU CLOSET 105 WOOD BATH 111 TILE MEDIA ROOM 107 CARPET CRAWL SPACE 108 CONCRETE MECH. ROOM 109 CONCRETE LAUNDRY 110 WOOD BUNK ROOM 112 CARPET ADU STAIR 106 CONCRETE UP CLOSET 115 CARPET BATH 114 TILE MEDIA BUILT-IN SUMP PUMP LOCATION REF. REPLACE BATHROOM FIXTURES REPLACE BATHROOM FIXTURES REPLACE BATHROOM FIXTURES T.O. SLAB EL. = 89'-0 3/4" V.I.F. T T T EGRESS WINDOW EGRESS WINDOW 1 HR SEP. WALL 1 HR SEP. WALL ELECTRICAL PANEL LOCATION2'-8"2'-5"1'-6"3'-6"1'-6"2'-9"1'-6"3'-9"1'-6"2'-9"1'-6"3'-6"1'-6"NEW ADDRESS FOR ADU UNIT, 971 B NEW STAIR TREADS, HANDRAILS, AND STRINGERS. EXISTING LANDINGS TO REMAIN NEW W/D UNITS IN LAUNDRY ROOM. SEE INTERIORS EXISTING ADU KITCHEN TO REMAIN 1 1 2 A-401 3 A-401 PROJECT SCALE PROPOSED LOWER LEVEL FLOOR PLAN 1/4" = 1'-0" 17007.00 A-101 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 PROPOSED LOWER LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A-101 0 2 4 8 Scale: 1/4" = 1'-0"NALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP. PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE. FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES, PORTLANT CEMENT OR EQ. ALL GAPS BETWEEN FRAMING AND REPLACED WINDOWS TO BE FILLED WITH INSULATION TO MAINTAIN THERMAL ENVELOPE. PER 2015 IECC R503.1.1 ALL NEW WALLS TO USE ZIP OR SIMILAR PANEL SYSTEM TO MAINTAIN AIR BARRIER CONTINUITY. PER 2015 IECC TABLE R402.4.1.1 1. 2. 3. 4. 5. 6. 7. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. FLOOR PLAN GENERAL NOTES (E) CONST. TO BE REMOVED OR NEW MASONRY WALL NEW CONSTRUCTION EXISTING CONSTRUCTION 9/27/17 EP SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 DE ET Maintain 1-hr dwelling separation SEE NOTES #1 PLANS 11/14/2017 tonyf 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"DN DN UP DN DN STAIR 203 WOOD STAIR 106 CONCRETE MUD ROOM 206 EXISTING STONE CLST 205 EXISTING STONE ENTRY 204 EXISTING STONE GARAGE 207 CONCRETE MSTR CLOSET 208 CARPET MSTR BATH 201 TILE MASTER BED 202 CARPET DN NEW GAS FIREPLACE NEW TUB REPLACE SHOWER BUILT IN REPLACE TOILET BENCH NEW BUILT IN NEW BUILT IN T.O. PLY EL. = 99'-7 7/8" V.I.F. T.O. PLY EL. = 100'-0" V.I.F. T.O. SLAB EL. = 99'-7 7/8" V.I.F. T 1 HR SEP. WALLS & CEILING OPEN TO ABOVE 3'-8"8'-2" 3'-3"4'-6 1/2"4'-3"4'-3"6'-2 1/4"2'-4" 1'-9 1/4"1'-0 3/4"4'-0 3/4"1'-0 3/4"NEW GLASS WALLS NEW STAIR TREADS, HANDRAILS, AND STRINGERS. EXISTING LANDINGS TO REMAIN T T T T T 1 1 2 A-401 4 A-401 PROJECT SCALE PROPOSED MAIN LEVEL FLOOR PLAN 1/4" = 1'-0" 17007.00 A-102 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 PROPOSED MAIN LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A-102 0 2 4 8 Scale: 1/4" = 1'-0"NALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP. PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE. FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES, PORTLANT CEMENT OR EQ. ALL GAPS BETWEEN FRAMING AND REPLACED WINDOWS TO BE FILLED WITH INSULATION TO MAINTAIN THERMAL ENVELOPE. PER 2015 IECC R503.1.1 ALL NEW WALLS TO USE ZIP OR SIMILAR PANEL SYSTEM TO MAINTAIN AIR BARRIER CONTINUITY. PER 2015 IECC TABLE R402.4.1.1 1. 2. 3. 4. 5. 6. 7. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. FLOOR PLAN GENERAL NOTES (E) CONST. TO BE REMOVED OR NEW MASONRY WALL NEW CONSTRUCTION EXISTING CONSTRUCTION 9/27/17 SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 INSTALLATION INSTRUCTIONS REQUIRED ON SITE AT TIME OF INSPECTION SEE NOTES #1 PLANS 11/14/2017 tonyf 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"DWDWREF/FRZ BUILT-IN KITCHEN 308 WOOD LIVING 303 WOOD DINING 301 WOOD BED/OFFICE 306 WOOD PANTRY 307 WOOD BATH 304 TILE STAIR 203 WOOD DECK 302 STONE OPEN TO BELOW DN CLOSET 305 WOOD NEW POCKET DOOR ROOF BELOW ROOF BELOW ROOF BELOW BUILT IN NEW GAS FIREPLACE BUILT IN NEW SHOWER REPLACE BATHROOM FIXTURES T.O. PLY EL. = 110'-0" V.I.F. T.O. PLY EL. = 109'-7 3/8" V.I.F. T 1'-9 3/4"1'-9 3/4"3'-1"9'-9" 6'-1 1/2"7'-2"3'-1 1/2"1'-9 3/4"1'-9 3/4"7'-1 1/2"2'-4" EXISTING HOOD AND RANGE TO REMAIN EXISTING SKYLIGHT ABOVE TO REMAIN NEW ISLAND 2'-1"3'-0"3'-0"7'-0 1/4" NOTE: SEE INTERIOR DRAWINGS FOR KITCHEN ELEVATIONS AND APPLIANCE SPECS NEW STAIR TREADS, HANDRAILS, AND STRINGERS. EXISTING LANDINGS TO REMAIN NEW GAS BBQ GRILL NEW METAL HANDRAIL NEW STONE DECK TO MATCH EXISTING 1 1 1 2 A-401 5 A-401 PROJECT SCALE PROPOSED UPPER LEVEL FLOOR PLAN 1/4" = 1'-0" 17007.00 A-103 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 PROPOSED UPPER LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A-103 0 2 4 8 Scale: 1/4" = 1'-0"NALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP. PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE. FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES, PORTLANT CEMENT OR EQ. ALL TIMBER WORK THAT IS TO REMAIN WILL BE SANDED AND RE-FINISHED. VERIFY FINISH WITH INTERIORS. ALL WOOD FLOORS THAT ARE TO REMAIN WILL BE SANDED, PATCHED WHERE NECESSARY, AND RE-FINISHED. VERIFY FINISH WITH INTERIORS. 1. 2. 3. 4. 5. 6. 7. LEGEND SEE A0.00 FOR SYMBOLS NOT SHOWN HERE. FLOOR PLAN GENERAL NOTES (E) CONST. TO BE REMOVED OR NEW MASONRY WALL NEW CONSTRUCTION EXISTING CONSTRUCTION 9/27/17 GR SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15 EE SEE NOTES #1 PLANS 11/14/2017 tonyf 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"W D F F F SDCO SDCO SDCO SDCO SDCO SDCO WR WR WRWR WRWR F BED 101 ADU BED 103 ADU BATH 102 ADU KITCHEN 104 CLOSET 113 ADU CLOSET 105 BATH 111 MEDIA ROOM 107 CRAWL SPACE 108 MECH. ROOM 109 LAUNDRY 110 BUNK ROOM 112 ADU STAIR 106 CLOSET 115 BATH 114 NOTE: ALL EXISTING LOG BEAMS ON CEILING IN MEDIA ROOM TO BE REMOVED NEW FAN IN LAUNDRY ROOM ART ART ART ART ART 2 A-401 1 PROJECT SCALE PROPOSED LOWER LEVEL RCP 1/4" = 1'-0" 17007.00 A-104 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 PROPOSED LOWER LEVEL RCP 1/4" = 1'-0" 1 A-104 0 2 4 8 Scale: 1/4" = 1'-0"NLEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES SP LARGE PENDANT LIGHT FIXTURE F SDCO 8'-0" WALL MOUNTED LIGHT FIXTURE WATER RATED LIGHT FIXTURE EXHAUST FAN SPEAKER CEILING/SOFFIT HEIGHT SYMBOL RECESSED DOWNLIGHT FLORESCENT LIGHT FIXTURE WR 1.ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. 2.VERIFY IN FIELD ALL EXISTING DIMENSIONS. 3.SEE INTERIOR ELEVATIONS FOR LOCATIONS OF SCONCES, TYP. 4.PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. 5.ALL LIGHTING TO MEET 2015 IECC LIGHTING REQUIREMENTS. 6.ALL TIMBER WORK THAT IS TO REMAIN WILL BE SANDED AND RE-FINISHED. VERIFY FINISH WITH INTERIORS. 7.ALL EXISTING 6" CANS TO BE REPLACED WITH 4" ELEMENT CANS W/ ROUND TRIM. CEILING MOUNTED SMOKE / CARBON MONOXIDE DETECTOR W/ BATTERY BACKUP 9/27/17 L 11/14/2017 tonyf 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"SDCO SDCO WR WR F SDCO F STAIR 203 WOOD STAIR 106 MUD ROOM 206 CLST 205 ENTRY 204 GARAGE 207 MSTR CLOSET 208 MSTR BATH 201 MASTER BED 202 OPEN TO ABOVE NOTE: ALL EXISTING LOG BEAMS ON CEILING IN MASTER BEDROOM TO BE REMOVED ART ART ART ART ART 2 A-401 1 1 1 1 NOTE: ALL EXISTING EXTERIOR SCONCES TO BE REPLACED PROJECT SCALE PROPOSED MAIN LEVEL RCP 1/4" = 1'-0" 17007.00 A-105 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 PROPOSED MAIN LEVEL RCP 1/4" = 1'-0" 1 A-105 0 2 4 8 Scale: 1/4" = 1'-0"NLEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES SP LARGE PENDANT LIGHT FIXTURE F SDCO 8'-0" WALL MOUNTED LIGHT FIXTURE WATER RATED LIGHT FIXTURE EXHAUST FAN SPEAKER CEILING/SOFFIT HEIGHT SYMBOL RECESSED DOWNLIGHT FLORESCENT LIGHT FIXTURE WR 1.ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. 2.VERIFY IN FIELD ALL EXISTING DIMENSIONS. 3.SEE INTERIOR ELEVATIONS FOR LOCATIONS OF SCONCES, TYP. 4.PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. 5.ALL LIGHTING TO MEET 2015 IECC LIGHTING REQUIREMENTS. 6.ALL TIMBER WORK THAT IS TO REMAIN WILL BE SANDED AND RE-FINISHED. VERIFY FINISH WITH INTERIORS. 7.ALL EXISTING 6" CANS TO BE REPLACED WITH 4" ELEMENT CANS W/ ROUND TRIM. CEILING MOUNTED SMOKE / CARBON MONOXIDE DETECTOR W/ BATTERY BACKUP EXTERIOR SCONCE 9/27/17 11/14/2017 tonyf L 11 1 A C E FBD 5 9 7 8 10 3 6 2 4 41'-0" 3'-9"16'-3"14'-0"2'-10"4'-2"50'-6"6'-0"2'-6"2'-6"6'-6"7'-6"6'-6"5'-6"5'-9"1'-9"6'-0"DWDWREF/FRZ BUILT-IN SDCO SDCO SP SP SP SP SP SP F WR KITCHEN 308 LIVING 303 DINING 301 BED/OFFICE 306 PANTRY 307 BATH 304 STAIR 203 DECK 302 CLOSET 305 RANGE HOOD EXISTING TO REMAIN EXISTING REPLACE LIGHT FIXTURE EXISTING REPLACE LIGHT FIXTURE BEAM BEAM SKYLIGHT EXISTING TO REMAIN SLOPE SLOPE SLOPESLOPE SLOPE SLOPE SLOPE NEW REVERSE COFFER CEILING IN ROOM 306 NEW FLAT CEILING ABOVE ENTRY L.E.D. LIGHT COVE 1'-0" 4" NEW CHANDELIER ART ART ART ART ART 2 A-401 1 1 1 NOTE: ALL EXISTING EXTERIOR SCONCES TO BE REPLACED PROJECT SCALE PROPOSED UPPER LEVEL RCP 1/4" = 1'-0" 17007.00 A-106 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 PROPOSED UPPER LEVEL RCP 1/4" = 1'-0" 1 A-106 0 2 4 8 Scale: 1/4" = 1'-0"NLEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES SP LARGE PENDANT LIGHT FIXTURE F SDCO 8'-0" WALL MOUNTED LIGHT FIXTURE WATER RATED LIGHT FIXTURE EXHAUST FAN SPEAKER CEILING/SOFFIT HEIGHT SYMBOL RECESSED DOWNLIGHT FLORESCENT LIGHT FIXTURE WR 1.ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. 2.VERIFY IN FIELD ALL EXISTING DIMENSIONS. 3.SEE INTERIOR ELEVATIONS FOR LOCATIONS OF SCONCES, TYP. 4.PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. 5.ALL LIGHTING TO MEET 2015 IECC LIGHTING REQUIREMENTS. 6.ALL TIMBER WORK THAT IS TO REMAIN WILL BE SANDED AND RE-FINISHED. VERIFY FINISH WITH INTERIORS. 7.ALL EXISTING 6" CANS TO BE REPLACED WITH 4" ELEMENT CANS W/ ROUND TRIM. CEILING MOUNTED SMOKE / CARBON MONOXIDE DETECTOR W/ BATTERY BACKUP EXTERIOR SCONCE 9/27/17 Recessed luminaires installed in building thermal envelope shall be sealed and IC-rated – IECC sec R402.4.5 L L L 11/14/2017 tonyf 8'-4 5/8"3'-0"7 1/4"11"7 1/2"11" 5 " 1 1 1 / 4 " E.Q.E.Q.E.Q. EXISTING WINDOW TO REMAIN EXISTING FLOOR STRUCTURE TO REMAIN EXISTING FLOOR STRUCTURE TO REMAIN EXISTING FLOOR STRUCTURE TO REMAIN EXISTING FLOOR STRUCTURE TO REMAIN EXISTING STAIR STRUCTURE TO REMAIN NEW STEEL RAILINGS W/ GLASS INFILL NEW WOOD FLOORING OVER EXISTING STRUCTURE NEW WOOD FLOORING ON LANDING NEW WOOD FLOORING OVER EXISTING STRUCTURE NEW CEILING BELOW LANDING T.O. FINISH @ LOWER LEVEL 89' 1-1/2" V.I.F. T.O. FINISH @ MAIN LEVEL 100'-0" V.I.F. T.O. FINISH @ UPPER LEVEL 110'-0" V.I.F. T.O. SLAB @ GARAGE 95'-2" V.I.F. T.O. FINISH @ LANDING 105'-0" V.I.F. NEW WOOD STRINGERS NEW WOOD STRINGER 3'-0"EXISTING WINDOW TO REMAIN EXISTING WALL TO REMAIN EXISTING FLOOR STRUCTURE TO REMAIN EXISTING FLOOR STRUCTURE TO REMAIN NEW STEEL RAILINGS W/ GLASS INFILL EXISTING WALL TO REMAIN T.O. FINISH @ LOWER LEVEL 89' 1-1/2" V.I.F. T.O. FINISH @ MAIN LEVEL 100'-0" V.I.F. T.O. FINISH @ UPPER LEVEL 110'-0" V.I.F. T.O. SLAB @ GARAGE 95'-2" V.I.F. T.O. FINISH @ LANDING 105'-0" V.I.F. NEW WOOD STRINGERS NEW WOOD STRINGERS NEW WOOD FLOORING ON LANDING NEW WOOD STRINGERS (BEHIND) DN DN UP UP 6'-5"4'-0"8'-0"10 RISERS @ 7-1/4" 9 TREADS @ 11" 8 RISERS @ 7-1/2" 7 TREADS @ 11" 8 RISERS @ 7-1/4" 7 TREADS @ 11" 8 RISERS @ 7-1/2" 7 TREADS @ 11" 8'-3"4'-0"8'-0"6'-5"4'-0"8'-0"EXISTING WINDOW TO REMAIN4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"EXISTING LOG BEAM TO BE TRIMMED DOWN AND BOXED W/ GYP. WALL BOARD PROJECT SCALE PROPOSED STAIR DETAILS 1/2" = 1'-0" 17007.00 A-401 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID # 273718295029971 UTE AVENUEC THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 04/06/2017 PERMIT SET 09/05/2017 CHANGE ORDER #1 1 PROPOSED STAIR SECTION 1/2" = 1'-0" 2 A-201 0 1 2 4 Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" PROPOSED STAIR ELEVATION 1/2" = 1'-0" 1 A-201 PROPOSED STAIR LOWER LEVEL PLAN 1/2" = 1'-0" 3 A-201 PROPOSED STAIR MAIN LEVEL PLAN 1/2" = 1'-0" 4 A-201 PROPOSED STAIR UPPER LEVEL PLAN 1/2" = 1'-0" 5 A-201 9/27/17 11/14/2017 tonyf