Loading...
HomeMy WebLinkAboutFile Documents.950 Cemetery Ln.0072.2018 (5).ARBKScale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 0.01/23/2019COVER SHEETDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18OFFICE PHONE:CONTACT:010302041A7.1LOCATION1A4.11A5.1COSTANZA REMODEL950 CEMETERY LANE- UNIT 1ASPEN COLORADOPARCEL ID NUMBER:ZONING:SITE AREA:BLDG USE:OCC. GROUP:CONST. TYPE:FIRE SPRINKLERS:LEGAL DESC'N:2735 122 83 001R-1514,386 sq.ft.ResidentialModerate Density ResidentialMulti-Level Framed DuplexABBREVIATIONSMATERIAL LEGENDVICINITY MAPSHEET INDEXPROJECT TEAMAPPLICABLE CODESPROJECT DATACOVERA 0.0 TITTLE/GENERAL INFORMATIONZONING SUBMISSIONZ-001 SURVEYZ-002 ZONING SUMMARYZ-003 RDS COMPLIANCEZ-004 SITE PLANZ-005 SITE COVERAGEZ-006 ROOF DEMOLITION CALCULATIONSZ-007 WALL DEMOLITION CALCULATIONSZ-008 FLOOR AREA CALCULATIONSZ-009 FLOOR AREA CALCULATIONSZ-101 FLOOR PLANSZ-102 FLOOR PLANSZ-103 ROOF PLANZ-201 HEIGHTSZ-202 HEIGHTSZ-203 HEIGHT OVER TOPOGRAPHYZ-301 EXISTING LANDSCAPE PLANZ-302 PROPOSED LANDSCAPE PLANZ-303 LIGHTING SPECSARCHITECTURAL DRAWINGSA 0.1 FAR CALCULATIONS - EXISTINGA 0.2 FAR CALCULATIONS - PROPOSEDA 0.3 FIRE AREAA 1.0 LOWER LEVEL FLOOR PLAN - EXISTINGA 1.1 MAIN LEVEL FLOOR PLAN - EXISTINGA 1.2 ROOF PLAN - EXISTINGA 1.3 LOWER LEVEL FLOOR PLAN - PROPOSEDA 1.4 MAIN LEVEL FLOOR PLAN - PROPOSEDA 1.5 ROOF PLAN - PROPOSEDA 2.0 LOWER LEVEL RCP - PROPOSEDA 2.1 MAIN LEVEL RCP - PROPOSEDA 3.0 ELEVATIONS - EXISTINGA 3.1 ELEVATIONS - EXISTINGA 3.2 ELEVATIONS - PROPOSEDA 3.3 ELEVATIONS - PROPOSEDA 4.0 SECTIONS - PROPOSEDA 4.1 SECTIONS - PROPOSEDA 5.0 DETAILSA 5.1 FIREPLACE DETAILSA6.0 DOOR AND WINDOW SCHEDULESSTRUCTURALS 1.1 FOUNDATION PLANS 2.1 MAIN FLOOR FRAMING PLANS 2.2 ROOF FRAMING PLANS 3.1 STRUCTURAL DETAILSMECHANICALM-1 MECHANICAL NOTESM-2 LOWER LEVEL MECHANICAL FLOOR PLANM-3 MAIN LEVEL MECHANICAL FLOOR PLANALL CODES REFERENCED ARE TO BE USED AS AMENDEDBY THE STATE OF COLORADO AND LOCAL JURISDICTION.FAR (FLOOR AREA RATIO)1. THESE DRAWINGS AND ANY ACCOMPANYING SPECIFICATIONS, ASINSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF THE ARCHITECTREGARDLESS OF WHETHER THE PROJECT FOR WHICH THEY WEREPRODUCED IS CONSTRUCTED OR NOT. THESE DOCUMENTS ARE NOT TOBE REUSED OR REPRODUCED IN ANY FORM OUTSIDE OF THE PROJECTCONTRACT WITHOUT WRITTEN AUTHORIZATION FROM THE ARCHITECT.2. THE CONTRACTOR SHALL BE RESPONSIBLE TO INSURE THATCONSTRUCTION CONFORMS TO ALL FEDERAL, STATE, LOCAL ANDRELATED CODES AND PRACTICES. SKILLED AND QUALIFIED WORKMEN INTHEIR ASSOCIATED TRADES SHALL PERFORM ALL WORK AT THE HIGHESTSTANDARD OF CRAFTSMANSHIP.3. THE ARCHITECT WILL PROVIDE DETAILS AND/OR DIRECTION FORDESIGN INTENT WHERE IT IS NEGLECTED IN THE DOCUMENTS ORALTERED BY EXISTING CONDITIONS.4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONSDEPICTED IN THESE DOCUMENTS AND SHALL NOTIFY THE ARCHITECT OFANY DISCREPANCIES, OMISSIONS, AND/OR CONFLICTS PRIOR TOPROCEEDING WITH THE WORK. ALL DIMENSIONS ON STRUCTURALDRAWINGS SHALL BE CHECKED AGAINST ARCHITECTURAL DRAWINGS.NOTIFY THE ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TOPROCEEDING WITH THE WORK.5. DO NOT SCALE DRAWINGS. THE DIMENSIONS SHALL TAKEPRECEDENCE OVER SCALED DRAWINGS.6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALLTRADES UNDER THEIR AUTHORITY WITH DRAWINGS AND/ORSPECIFICATIONS.7. THE OWNER AND/OR ARCHITECT SHALL APPROVE ANY “EQUAL”MATERIALS, EQUIPMENT, FIXTURES, ETC. PRESENTED BY THECONTRACTOR. THE CONTRACTOR SHALL SUPPLY THE ARCHITECT AND/OROWNER WITH SAMPLES OF ALL FINISH MATERIALS AND SHALL NOTPROCEED WITH INSTALLATION UNTIL THE ARCHITECT AND/OR OWNERISSUES AN APPROVAL. ALL WORK MUST CONFORM TO THE APPROVEDSAMPLE. THE CONTRACTOR SHALL FORWARD ALL REQUIRED SUBMITTALSAND VERIFICATIONS TO THE ARCHITECT WITH ADEQUATE TIME FORREVIEW AS NOT TO DELAY THE WORK IN PROGRESS.8. IF REQUIRED, THE CONTRACTOR SHALL PROVIDE THE BUILDINGDEPARTMENT WITH A CONSTRUCTION MANAGEMENT PLAN PRIOR TOOBTAINING A BUILDING PERMIT.9. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ARCHITECTFOR WINDOWS, DOORS, CASEWORK, METAL DETAILING, STAIRS,FIREPLACE, AND ANY OTHER WORK NOTED IN THE DOCUMENTS.FABRICATION SHALL NOT PROCEED ON ANY OF THESE ITEMS UNTIL THECONTRACTOR RECEIVES APPROVED SHOP DRAWINGS FROM THEARCHITECT. ALL WORK SHALL CONFORM TO THE APPROVED SHOPDRAWINGS.10. THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING,TEMPORARY SUPPORTS, SHORING, ETC. SHALL BE THE SOLERESPONSIBILITY OF THE CONTRACTOR AND HAS NOT BEEN CONSIDEREDBY THE ARCHITECT OR ENGINEER. THE CONTRACTOR IS RESPONSIBLEFOR THE STABILITY OF THE STRUCTURE THROUGHOUT THE DURATION OFCONSTRUCTION AND SHALL CONFORM TO ALL FEDERAL, STATE, ANDLOCAL O.S.H.A. REGULATIONS. THE CONTRACTOR SHALL BERESPONSIBLE FOR THE SAFETY AND CARE OF NEIGHBORING PROPERTIESUNTIL THE PROJECT IS COMPLETED.11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REQUESTINGBUILDING INSPECTIONS AS APPLICABLE TO THE INTERNATIONALBUILDING / RESIDENTIAL CODE AND LOCAL ORDINANCES.12. THE CONTRACTOR SHALL COORDINATE ALL OPENINGS THROUGHWALLS, FLOORS, AND CEILINGS WITH THE ARCHITECTURAL, STRUCTURAL,MECHANICAL, PLUMBING, ELECTRICAL, AND LIGHTING DRAWINGS. REFERTO THE STRUCTURAL ENGINEER FOR ALLOWABLE OPENING SIZES /REQUIREMENTS IN STRUCTURAL MEMBERS.13. THE CONTRACTOR WILL BE ACCOUNTABLE FOR THE STONE MASON’STAKE-OFFS AND WILL ASSUME THE RESPONSIBILITY OF COORDINATINGANY ITEMS THAT REQUIRE CLARIFICATION DURING THE BIDDINGPROCESS.14. THE ARCHITECT WILL VERIFY IN FIELD ALL LIGHTING FIXTURES,SWITCHES, MECHANICAL GRILLES, REGISTERS, AND THERMOSTATLOCATIONS PRIOR TO INSTALLATION. THE CONTRACTOR SHALL ROUGH-INLIGHTING FIXTURES AND ILLUSTRATE SWITCH, REGISTER, AND GRILLELOCATIONS PRIOR TO THE ARCHITECT WALK-THROUGH.15. ALL EXTERIOR PENETRATIONS SUCH AS GRILLES, BOILER FLAPS, ETC.TO BE COPPER OR ENCLOSED BY COPPER FITTINGS.- 2015 INTERNATIONAL RESIDENTIAL CODE- 2015 INTERNATIONAL BUILDING CODE- 2015 INTERNATIONAL ENERGY CONSERVATION CODE- CITY OF ASPEN LAND USE CODEOFFICE PHONE:CONTACT:KIM RAYMOND ARCHITECTS, INC.300 E. Hyman Ave., Suite 100Aspen, CO 81611970.925.2252KIM RAYMOND / kim@krai.usLIVABLEUNIT 1 1816.79 SFUNIT 2 1787.28 SFGARAGEUNIT 1 103.00 SFUNIT 2 143.00 SFDECKUNIT 1 363.00 SFUNIT 2 628.00 SFEXCEMPT 731.70 SFTOTAL 4109.37 SF*REFER TO ARCHITECTURAL DOCUMENTSA 0.2 FOR THE FAR GRAPHIC ILLUSTRATION.JST. JOISTVINYL COMPOSITION TILEVCTYARDWROUGHT IRONWOODWITHOUTWITHWEIGHTWEATHER PROOFWAINSCOTWINDOWWATER CLOSETVERTICALVOLT AMPEREVERIFY IN FIELDVAPOR BARRIERURINALUNFINISHEDTYPICALTRANSFORMERTOILETTHROUGHTHICKTHREADEDTHRESHOLDTELEPHONETELEVISION OUTLETTUBE STEELTOP OF WALLTOP OF SLABTOP OF MASONRYTOP OF JOISTTOP OF FOOTINGTOP OF CURBTOP OF BEAMTOP OFTELEPHONE MOUNTING BOARDTHROUGH BOLTTONGUE AND GROOVESYSTEMSYMMETRICALSWITCHSUSPENDEDSTEELSTANDARDSOUND TRANSMISSION CLASSSQUARE INCHESSQUARE FEETSPEAKERSPECIFICATIONSSPACESIMILARSHEATHINGSHEETSERVICE ENTRANCE SECTIONSECTIONSCHEDULESELF CLOSINGSTAINLESS STEELSKYLIGHTSHUT OFF VALVESMOKE DETECTORSOLID COREREMOVEROOMREVISIONRETURNREQUIREDREINFORCEDREFERENCEREFRIGERATORRIGHT OF WAYROUGH OPENINGROOF DRAIN OVERFLOWROOF DRAIN LEADERRADIUSQUANTITYQUARRY TILEPOWERPOLYVINYLCLORIDEPARTITIONPOUNDS PER SQUARE INCHPOUNDS PER SQUARE FOOTPREFABRICATEDPERFORATEDPORCELAINPLYWOODPLUMBINGPLASTICPLATEPLASTERPHASEPERPENDICULARPOINT OF CONNECTIONPLASTIC LAMINATEPROPERTY LINEPRECAST CONCRETEOPPOSITEOPENINGOVER HEADOUTSIDE AIR INTAKEOUTSIDE RADIUSORNAMENTAL IRONOVER HANGOUTSIDE DIAMETERON CENTERNOMINALNUMBERNAILERNOT FOR CONSTRUCTIONNON-CORROSIVE METALNOT TO SCALENOT IN CONTRACTMULLIONMETALMODULARMISCELLANEOUSMINIMUMMANUFACTURERMANUFACTURINGMEDIUMMECHANICALMAXIMUMMATERIALMASONRYMARBLEMASONRY OPENINGMALLEABLE IRONMANHOLEMACHINE BOLTLAMINATED VENEER LUMBERLIGHTINGLIGHTLINOLEUMLINEARLEADLAVATORYLATERALLAMINATELINEAR FEETLIGHT EMITTING DIODEKNOCK OUTKILN DRIEDKNOCK DOWNJOINTJUNCTIONJUNCTION BOXINTERIORINSULATIONINCLUDE, INCLUSIVEIMPREGNATEDINTERMEDIATE METALLIC CONDUITISOLATED GROUNDIDENTIFICATIONINSIDE FACEINSIDE DIAMETERINTERCOM OUTLETHYDRAULICHOT WATERHEATING, VENTILATING & AIR CONDITIONINGHEATERHORIZONTALHEIGHTHARDWAREHARDBOARDHANDICAPPEDHOLLOW METALHOLLOW COREHOSE BIBBGYPSUM BOARDGYPSUMGALVANIZED RIGID TUBINGGATE VALVEGRADE MARKGLUE LAMINATED BEAMGLASSGROUND FAULT INTERRUPTERGROUND FAULT CIRCUIT INTERRUPTERGARAGEGALVANIZEDGAUGEGALVANIZED IRONFURNISHFOOTINGFIRE PROOFFLUORESCENTFLOORINGFLOORFINISHFIRE HOSE CABINETFOUNDATIONFIRE DEPARTMENT CONNECTIONFIRE ALARM CONTROL PANELFABRICATEFIBERGLASSFLOOR SINKFACE OFFIELD NAILINGFIRE EXTINGUISHERFLOOR DRAINFLOOR CLEAN OUTFAN COILFIRE ALARMEXTERIOREXISTINGEXHAUSTEXCAVATEELECTRIC DRINKING COOLEREVAPORATIVE COOLERESTIMATEEQUIPMENTEQUALELECTRICAL NON-METALLIC TUBINGELECTRICAL METALLIC TUBINGELECTRICAL METALLIC CONDUITELEVATOR"ELECTRIC, ELECTRICAL"ELEVATIONEACHEACH WAYEND NAILINGEXPANSION JOINTEXHAUST FANEXPANSION ANCHORDOORDOWNDEAD LOADDIMENSIONDIAGONALDIAMETERDEMOLITIONDOUBLEDISHWASHERDOWN SPOUTDECOMPOSED GRANITEDRINKING FOUNTAINPENNYCOPPERCONTRACTORCONTINUOUSCONSTRUCTIONCONCRETECOMBINATIONCOLUMNCENTEREDCONCRETE MASONRY UNITCLEARCLOSETCAULKINGCEILINGCENTERLINECIRCUIT BREAKERCHANNELCUBIC FEET PER MINUTECERAMICCEMENTCLOSED CIRCUIT TELEVISIONCAMBERCABINETCERAMIC TILECLEAN OUTCONTROL JOINTCAST IN PLACECONSTRUCTION DOCUMENTSCONCRETE ASBESTOS PIPEBRONZEBEARINGBRASSBEAMBLOCKINGBLOCKBUILDINGBOARDBACK OF CURBBUILT UPBOTTOM OF FOOTINGBOTTOM OFBOUNDARY NAILINGBENCH MARKANGLEAMERICAN WIRE GAUGEAVERAGEASPHALTANNEALEDALTERNATEALUMINUMAIR HANDLER UNITABOVE GRADEADDITION or ADDENDUMACOUSTICAL CEILING TILEACOUSTICASBESTOS-CEMENT BOARDABOVEACRYLONITRILE-BUTADIENE-STYRENEAGGREGATE BASE COURSEAIR CONDITIONINGABOVE FINISHED GRADEABOVE FINISHED FLOORANCHOR BOLTAMPERESYD.W.I.WD.W/OW/WT.WPWCTWDWWCVERT.VAV.I.F.V.B.URUNF.TYP.TRANS.TLT.THRUTHK.THD.TH.TEL.T.V.T.S.T.O.W.T.O.S.T.O.M.T.O.J.T.O.F.T.O.C.T.O.B.T.O.T.M.B.T.B.T & GSYS.SYMSWSUSP.STL.STD.STCSQ. IN.SQ. FT.SPKR.SPECSSPA.SIM.SHT'G.SHSESSECT.SCHED.SCS/SS/LS.O.V.S.D.S.C.RMV.RMREV.RET.REQ'D.REINF.REF.REFR.O.W. or R/WR.O.R.D.O.R.D.L.RQTY.Q.T.PWR.PVCPTN.PSIPSFPREFAB.PERF.PORC.PLYWD.PLUMB.PLAS.PLT.PL.PH or ØPERP. orP.O.C.P.LAM.P.L.P.C.OPPO.OPNG.OHOAIO.R.O.I.O.H.O.D.O.C.NOM.NO.NLR.NFCNCMN.T.S.N.I.C.MULMTL.MODMISC.MIN.MFR.MFG.MED.MECH.MAX.MAT'LMAS.MAR.M.O.M.I.M.H.M.B.LVLLTG.LT.LINO.LIN.LD.LAVLAT.LAML.FT.L.E.D.KOKDK-DJT.JCTJ-BOXINT.INSUL.INCL.IMPGIMCIGIDI.F.I.D.I.C.HYD.HWHVACHTRHOR.HGT.HDWHDBD.H/CH.M.H.C.H.B.GYP. BD.GYP.GRCGMGMGLBGLGFIGFCIGAR.GALV.GA.G.I.FURN.FTG.FPFLUOR.FLG.FLFIN.FHCFDN.FDCFACPFAB.F/GF.S.F.O.F.N.F.E.F.D.F.C.O.F.C.F.A.EXT.EXIST. or EEXH.EXCEWCEVAP.EST.EQUIP.EQ.ENTEMTEMCELEV.ELECT.ELEA.E.W.E.N.E.J.E.F.E.A.DRDN.DLDIM.DIAG.DIA. or ØDEMODBL.D/WD.S.D.G.D.F.dCUCONTR.CONT.CONST.CONC.COMB.COL.CNTRD.CMUCLR.CLO.CLKG.CLG.CL or C.L.CKT. BKR.CHCFMCERCEM.CCTVCAM.CABC.T.C.O.C.J.C.I.P.C.D.C.A.P.BRZBRG.BRBM.BLKG.BLK.BLDGBD.B/CB.U.B.O.F.B.O.B.N.B.M.AWGAVGASPH.ANLALT.AL. or ALUM.AHUAGADD.ACTACOU.ACBABV.ABSABCA/CA.F.G.A.F.F.A.B.ASLOPE TO DRAINS.T.D.GENERAL NOTESFINISH WOODWOOD STUDBLOCKINGSTEELSTEEL STUDFRAMED WALLBATT INSULATIONORPLYWOODPLYWOODORGLU-LAMCONCRETESTONECMUSANDGRAVELGWBCOMPACTED SOILSPRAY-FOAM INSULATIONRIGID INSULATIONGRID LINEBREAK LINE MATCH LINEREVISIONA9.1ELEVATION MARKERSECTION MARKERDETAIL CUTDETAIL1A6.1ELEVATION100AROOM NAME101INTERIOR ELEVATION MARKERELEVATION NUMBERSHEET NUMBERSECTION NUMBERSHEET NUMBERDETAIL NUMBERSHEET NUMBERSPOT ELEVATIONDOOR MARKWINDOW MARKROOM NAME AND NUMBERELEVATION NUMBERSHEET NUMBERSYMBOL LEGENDSubdivision: SnowbunnyLot: 4GENERAL CONTRACTOR:ARCHITECT:OWNER:STRUCTURAL ENGINEER:MECHANICAL ENGINEER:CIVIL ENGINEER:TBD /OFFICE PHONE:CONTACT:TBDTBDCarbondale, CO 81623970.xxx.xxxxJACK ALBRIGHT /jack@albright-associates.comOFFICE PHONE:CONTACT:ALBRIGHT & ASSOCIATES402 Park Ave., Unit EBasalt, CO 81621970.927.4363JUSTIN YARNELL /justin@theyarnells.comOFFICE PHONE:CONTACT:YARNELL CONSULTING & CIVIL DESIGN229 Midland AveBasalt, CO 81621970.927.4363MARK BURGGRAAF /mburggraaf@pagosa.netOFFICE PHONE:CONTACT:BURGGRAAF ASSOCIATES INC.236 S. 3rd. StreetMontrose, CO 81401970.946.3103CHARLES & PHYLLIS COSTANZAPHYLLIS COSTANZA/phylliskcostanza@yahoo.com970.989.3441 Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 0.11/23/2019FAR PLANS -EXISTINGDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18438 sq ftDW171 sq ft40 sq ft94 sq ft51 sq ft75 sq ft220 sq ft8'-7 1/2"18'-3 1/2"27'-6 1/2"6'-5"3'-10 1/4"22'-11 3/4"18'-2"4'-5 3/4"1'-1 1/4"21'-10 1/4"4'-5 3/4"1'-1 1/4"18'-2"4'-1 3/4"6'-4 1/4"22'-11 3/4"22'-7 1/2"21'-10 1/4"9' TYP6'-6" TYP6'-4 1/4" TYP5'-1 1/2"6'-5"27'-1 3/4"27'-7 3/4"6'-5"26'-11"22'-7 1/2"13'-3 1/2"6'-4 1/4"2'-11 3/4"40 sq ft10 sq ft164 sq ft41 sq ft207 sq ft204 sq ft41 sq ft197 sq ft542 sq ft221 sq ft51 sq ft12345123 4 5 67123 4 5 67EDGE OF BUIILDING ABOVEEDGE OF BUIILDING ABOVE8818 sq ft91 sq ft25 sq ft28 sq ft54 sq ft34 sq ft46 sq ft157 sq ft678141110912139 10 11121314UNIT 1 LOWER LEVELUNIT 2 LOWER LEVEL9101112131476 sq ft252 sq ft15 sq ft162 sq ft207 sq ft209 sq ft76 sq ft97 sq ft147 sq ft184 sq ft138 sq ft27 sq ft67891011121314151234 23'-2 1/4"11'-9 1/2"29'-2 1/4"1'-10"17'-11 3/4"22'-11 3/4"23'-2 1/4"6'-3 3/4"11'-9 1/2"9'-5 1/2"12'-2 1/4"23'-1/2"9'-6"8'9'8'14'-6 1/2"9'-6"9'12'13'8'22'-11 3/4"6'-3 3/4"9'-5 1/2"1'-2"14'-6 1/2"23'-1/2"12'-2 1/4"17'-11 3/4"29'-2 1/4"518 sq ft1,297 sq ft190 sq ftEXEMPT FROM FAR<30" IN HEIGHTEXEMPT FROM FAR<30" IN HEIGHTEXEMPTLIVINGDINING52 sq ft102 sq ft118 sq ft470 sq ft142 sq ft1,306 sq ft131 sq ft132456789101234567891011UNIT 1UNIT 2 MAIN LEVELUNIT 1 MAIN LEVELGARAGEFAR LEGENDEXEMPTDECKLIVABLE AREA0 4' 8' 16'SCALE: 1/8" = 1'-0"1LOWER LEVEL FAR - EXISTING0 4' 8' 16'SCALE: 1/8" = 1'-0"2MAIN LEVEL FAR - EXISTING Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 0.21/23/2019FAR PLANS-PROPOSEDDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/1860 sq ft35 sq ft51 sq ft110 sq ft49 sq ft257 sq ft88 sq ft170 sq ft94 sq ft36 sq ft28 sq ft84 sq ft30 sq ft174 sq ft46 sq ft8'-7 1/2"18'-3 1/2"27'-6 1/2"6'-5"3'-9"5'-4 1/4"12'-2 3/4"3'-9"6'-5"9'-7"27'-6 1/2"6'-5"26'-11"18'-3 1/2"8'-7 1/2"27'-6 1/4"26'-11"6'-5"220 sq ft28 sq ftNEW UTILITY ROOMEXEMPT FROM FAR>5'-6" IN HEIGHT12345ARCH 93'-8"EDGE OF BUIILDING ABOVEEDGE OF DECK ABOVEEDGE OF BUIILDING ABOVE2345678EDGE OF BUIILDING ABOVE1818 sq ft5'-4 1/4"11'-11 3/4"9'-7"678DOWNDOWNFRONT PORCHEXEMPT FROM FAR<30" IN HEIGHTELEV. 7,860.22' =ARCH 95'-1 1/2"ELEV 7,865'- 1 1/8"ARCH 100'-0"1,443 sq ft184 sq ft142 sq ft470 sq ftGARAGEFAR LEGENDEXEMPTDECKLIVABLE AREA0 4' 8' 16'SCALE: 1/8" = 1'-0"1LOWER LEVEL FAR- PROPOSED0 4' 8' 16'SCALE: 1/8" = 1'-0"2MAIN LEVEL FAR- PROPOSED Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 0.31/23/2019FIRE AREADATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18454 sq ft1 2 UP4RISE(7")3RUN(11")1234UP8RISE(7 3/4")7RUN(11")ARCH 93'-8"EDGE OF BUIILDING ABOVEEDGE OF DECK ABOVEEDGE OF BUIILDING ABOVEEDGE OF BUIILDING ABOVE819 sq ftDOWNDOWNELEV. 7,860.22' =ARCH 95'-1 1/2"ELEV 7,865'- 1 1/8"ARCH 100'-0"1,387 sq ft434 sq ft33 sq ft445 sq ft9'4"0 1/2"3'3 1/2"0 1/2"12'-6 1/4" 2'-8" 11'-1 1/4" 7 1/4"3'-6" 0 3/4" 3'-3 3/4"2'-9 1/2" 0 3/4" 3'-3/4"4'-4 3/4"5'-3" 4 1/2"19'-7"12'-6 1/4"2'-10 1/2"19'-7" 10 1/4" 3'563 sq ft488 sq ft1,240 sq ftUNIT 2 MAIN LEVELUNIT 2 UPPER LEVELUNIT 2 LOWER LEVELWINDOW WELLARCH 88'-6"ARCH 88'-6"27'-5 3/4"FIRE AREA UNIT1 LOWER LEVEL 1,273 UNIT 1 MAIN LEVEL 1,854 UNIT 1 TOTAL 3,127 UNIT 2 LOWER LEVEL 488 UNIT 2 MAIN LEVEL 1,685 UNIT 2 UPPER LEVEL 563 UNIT 2 TOTAL 2,736 DUPLEX TOTAL 5,863* A FIRE SPRINKLER SYSTEM ISREQUIRED IF THE FIRE AREA ISGREATER THAN 5,000 SF.0 4' 8' 16'SCALE: 1/8" = 1'-0"1LOWER LEVEL FIRE AREA0 4' 8' 16'SCALE: 1/8" = 1'-0"2MAIN LEVEL FIRE AREA Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 1.01/23/2019LOWER LEVELPLAN-EXISTINGDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18W05W02W03W04DWCC336677BBFF112244AA66CD74'-4 3/4"22'-4 1/4"7'-9 1/2"15'-5"12'-11"9'-4 1/2"6'-6 1/2"41'-3"11'-11 3/4"5'-10 1/4" 8'-1 3/4"13'-1 3/4" 2'-1 1/2"EAST2#LayIDEASTZ-202SOUTHZ-201NORTHZ-201WESTZ-202EAST2A 3.44321 IE 1.28765 IE 1.2INSTALL NEW RADIANTHEAT, TYP.FLOOR ABOVEBEDROOM 2EXIST. ELECT. PNLEXISTINGBATHBEDROOM 1CLOSET 2BATH 2CLOSETCLOSETEXISTING OFFICEEXIST.HWHNEWELECT. PNLEDGE OF BUIILDING ABOVEEDGE OF DECK ABOVEEDGE OF BUIILDING ABOVEEDGE OF BUIILDING ABOVECA 4.1CA 4.11A 4.01A 4.0#DrgID#LayID#DrgID#LayIDAA 4.0AA 4.0BA 3.4BA 3.4A#LayID#DrgID#LayIDBA 3.4BA 3.42A 5.055EEDD0 2' 4' 8'SCALE: 1/4" = 1'-0"1EXISTING LOWER LEVEL PLAN Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 1.11/23/2019MAIN LEVELPLAN-EXISTINGDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18W22D03W11Sill -3'-1 1/4"D03CC336677BBFF112244AA67891011121314151234 WRGDF66CDDWEAST2#LayIDEASTZ-202SOUTHZ-201NORTHZ-201WESTZ-202EAST2A 3.474'-4 3/4"22'-4 1/4"7'-9 1/2"15'-5"12'-11"15'-11"41'-3"11'-11 3/4"5'-10 1/2" 8'-1 1/2"12'-8 1/4"2'-7"CA 4.1CA 4.11A 4.01A 4.0#DrgID#LayID#DrgID#LayIDAA 4.0AA 4.0BA 3.4BA 3.4A#LayID#DrgID#LayID1234 IE 1.11234 IE 1.31#DrgID23 IE 1.44IE 1.45IE 1.4#DrgID#LayIDTOP OF ROOF BELOWLIVING AREAEXISTING DECKDININGSTAIRSENTRYNEWENLARGEDDECKBENCHTALL LINEN /BROOMMASTERBEDROOMMASTERBATHMASTERCLOSETKITCHENSITTING AREALIVINGDINING3X7TABLEBA 3.4BA 3.455EEDD2A 5.02A 5.02A 5.00 2' 4' 8'SCALE: 1/4" = 1'-0"1EXISTING MAIN LEVEL PLAN Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 1.21/23/2019ROOF PLAN-EXISTINGDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18CC336677BBFF112244AA66CDEAST2#LayIDEASTZ-202SOUTHZ-201NORTHZ-201WESTZ-202EAST2A 3.4CA 4.1CA 4.11A 4.01A 4.0#DrgID#LayID#DrgID#LayIDAA 4.0AA 4.0BA 3.4BA 3.4A#LayID#DrgID#LayID EXISTING GARAGEROOFPITCH TO DRAIN EXISTINGDECKBELOWEXISTINGENTRY ROOFPITCH TO DRAINEXISTING ROOF2:12 PITCHEXISTING ROOF2:12 PITCHEXISTINGLOWER ROOFEXISTINGDECKBELOWUNIT 2 ROOF SHOWNFOR REFERENCE ONLYBA 3.4BA 3.455EEDD0 2' 4' 8'SCALE: 1/4" = 1'-0"1EXISTING ROOF PLAN Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 1.31/23/2019LOWER LEVELPLAN-PROPOSEDDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/1812UP4RISE(7")3RUN(11")1234UP8RISE(7 3/4")7RUN(11")W06W05W02W03D40D36D34D35D31D37D33D32D38CC336677BBFF112244AA6' 0"19'-10 3/4"10 1/4"3" 12'-6 1/2" 4 1/2"13'-4 1/2"74'-4 3/4"22'-4 1/4"7'-9 1/2"15'-5"12'-11"9'-4 1/2"6'-6 1/2"41'-3"11'-11 3/4"5'-10 1/4" 8'-1 3/4"13'-1 3/4" 2'-1 1/2"14'-11"10'-3/4"10'-3 1/4"5 1/2"2 3/4"5'-6"5'-1 3/4"3'-3" 11'-2 3/4"3'6'-4 1/2"3'-1/2"3 1/2"6'-11 1/2"3 1/2"1'-7 3/4"1'-6 1/4"0 1/2"6'-1/2"7 1/4"2" 1' 2'3'-9 3/4"2'-9 1/2"1'-4 1/2"3'-1"3 1/2"3'-2 3/4" 1'-6 1/2"3'-7 1/2" 3'-5 1/2" 2'-1" 3 1/2" 4'-3/4"EAST2#LayIDSOUTHZ-201NORTHZ-201WESTZ-202EAST2A 3.44321 IE 1.28765 IE 1.2APPROX. LOCATION OF TREES,SEE SURVEYAPPROX. LOCATION OF TREES,SEE SURVEYHWHCLOSET1CLOS. 2NEW UTILITYROOMNEW ELECT. PNLEXIST'GSLABLANDINGTOREMAINFAMILYROOMOWNER'SCLOSETBEDROOM2BATH 1BEDROOM1UP2 NEWRISERSUPEDGE OF BUIILDING ABOVEEGRESSWINDOWEGRESSWINDOWSETBACKEDGE OF BUIILDING ABOVESLOPE TODRAINBENCHTRENCH DRAINBATH2DRESSERCLOSET1FAMILYROOMOWNER'SCLOSETBEDROOM2BATH 1BEDROOM1BATH2CA 4.1CA 4.11A 4.01A 4.0#DrgID#LayID#DrgID#LayIDAA 4.0AA 4.0BA 3.4BA 3.4A#LayID#DrgID#LayIDBA 3.4BA 3.43 1/2" 8'-10" 5 1/2" 5'-11" 6" 3'-3 1/2" 5 1/2"2A 5.0HATCHED WALLINDICATES 1-HOUR FIRE WALLASSEMBLY PERDETAIL NOTED55EEDDNSCALE: 1/4" = 1'-0"LOWER LEVEL PLAN Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 1.41/23/2019MAIN LEVELPLAN-PROPOSEDDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18DOWNDOWNW14W13W11W18D16D17D21D18W17W28D03DG1D01D02W15W12D06W23W24D05W25W27W26W25CC336677BBFF112244AAWDDWEAST2#LayIDSOUTHZ-201NORTHZ-201WESTZ-202EAST2A 3.411'-11 3/4"23'-6"22'-4 3/4"5 1/2"1'-7 3/4"2'-6 1/2"1'-7 3/4"3 1/2"5'-1/4" 2'-10 1/4" 4'-4"27'-4"18'-9 1/2"74'-4 3/4"22'-4 1/4"7'-9 1/2"15'-5"12'-11"15'-11"41'-3"11'-11 3/4"5'-10 1/2" 8'-1 1/2"12'-8 1/4"2'-7"4'-6 1/2"3 1/2"5'-4"4 1/2"5 1/2"1'-4 3/4"1'-6 1/4"3 1/2" 5'-8 1/2" 5 1/2"11'-11"8'-2 1/2"5'-3"15'-3 1/4"4'-3/4" 3'-9 1/2"10'-1/4" 1'-5"3'-1"13'-1 3/4"2'-9 1/4"2'-1 1/4" 4'-10" 5'-7" 2'-8 3/4"9 1/4" 3"20'-10 1/4"19'-7 1/4"2'-9 1/4"3" 5 1/2"2'-1 1/2" 2'-3 1/2" 3 1/2" 3'-5"6'-5 1/2" 6'-5 1/2"8'-1 3/4"6'-4 1/4"3'-1 1/2" 5'-10" 3'-5"3'-9 3/4" 3'-2 1/4" 3'-2 1/4"CA 4.1CA 4.11A 4.01A 4.0#DrgID#LayID#DrgID#LayIDAA 4.0AA 4.0BA 3.4BA 3.4A#LayID#DrgID#LayID1234 IE 1.11234 IE 1.31#DrgID23 IE 1.44IE 1.45IE 1.4#DrgID#LayIDTOP OF ROOF BELOWMED CABNEW SINGLE DOORRECONFIGURE ENTRY STORAGENEW LIFT-AND-SLIDE DOOR,REBUILD WALL PER STRUCT.ENCLOSE CARPORTTO CREATEGARAGELAUNDRYKITCHENMASTER BEDROOMPOWDERMASTERBATHW/CSTEAMSHOWERBBQDRESSERDESKPANTRYMASTERCLOSETCUBBIESOVENSBOOTDRYERCLOSETW/BENCHBELOWSKISBENCHLINENENTRYELEV. 7,860.22' =ARCH 95'-1 1/2"ELEV 7,865'- 1 1/8"ARCH 100'-0"LIVINGDININGNOTE: SEE ROOF PLAN FORCLERESTORY WINDOW INFORMATIONSLOPE TODRAINTRENCH DRAINBA 3.4BA 3.455EEDDFD192A 5.02A 5.02A 5.0HATCHED WALLINDICATES 1-HOUR FIRE WALLASSEMBLY PERDETAIL NOTEDNSCALE: 1/4" = 1'-0"MAIN LEVEL PLAN495.7 sf Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 1.51/23/2019ROOF PLAN-PROPOSEDDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18W37W29W36W34W35W31W32W33CC336677BBFF112244AA66CDEAST2#LayIDEASTZ-202SOUTHZ-201NORTHZ-201EAST2A 3.4CA 4.1CA 4.11A 4.01A 4.0#DrgID#LayID#DrgID#LayIDAA 4.0AA 4.0BA 3.4BA 3.4A#LayID#DrgID#LayID4'1'-6"4'1'1'6"1'-6"VIF2'-7"4'1'3'-1/2"4'-5 3/4"4'-10 3/4"19'-1 3/4"5'-3 1/2"4'-8 1/4"2'-8 3/4"NEW 2X6 WALL OVER BEAM BELOWLINE OF WALL BELOWFIREPLACE FLUEREPLACE EXIST'G GUTTER AT NEWROOF HT. AND DRAIN TO LOWERGUTTER WITH EXISTING DOWNSPOUTEXIST'G GUTTER TO REMAIN.DOWNSPOUT TO FRONT LAWN TOREMAINCURRENT DRAINAGE TOGREEN SPACE BELOWNEW SCUPPER &DOWNSPOUTEXIST'G FREEDRAINAGE TO GREENSPACE TO REMAINTERMINATION OF NEWDOWNSPOUT ATGRADE BELOWADJUST EXISTING ROOFFOR NEW PLUMB WALL2:12 PITCHNEW ENTRYROOFPITCH TO DRAINPITCH TO DRAINUNIT 2 ROOF SHOWNFOR REFERENCE ONLYEXISTINGLOWER ROOFEXISTING ROOF WITHNEW EXTENSION2:12 PITCH2:12 PITCH1/4:12MIN.BA 3.4BA 3.455EEDDSCALE: 1/4" = 1'-0"ROOF PLAN Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 2.01/23/2019LOWER LEVELRCP -PROPOSEDDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18FFFFCMCMCC336677BBFF112244AA74'-4 3/4"22'-4 1/4"7'-9 1/2"15'-5"12'-11"9'-4 1/2"6'-6 1/2"41'-3"11'-11 3/4"5'-10 1/4" 8'-1 3/4"13'-1 3/4" 2'-1 1/2"SOFFIT, V.I.F.OPEN TOSTAIRS ABOVEEDGE OF BUIILDING ABOVEEDGE OF DECK ABOVEEDGE OF BUIILDING ABOVEEDGE OF BUIILDING ABOVE9'-7 3/8" CEILING5'-6" CEILINGCA 4.1CA 4.11A 4.01A 4.0#DrgID#LayID#DrgID#LayIDAA 4.0AA 4.0BA 3.4BA 3.4A#LayIDBA 3.4BA 3.42A 5.055EEDD0 2' 4' 8'SCALE: 1/4" = 1'-0"1PROPOSED LOWER LEVEL RCP Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 2.11/23/2019MAIN LEVELRCP -PROPOSEDDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18CC336677BBFF112244AAFFF66CD74'-4 3/4"22'-4 1/4"7'-9 1/2"15'-5"12'-11"15'-11"41'-3"11'-11 3/4"5'-10 1/2" 8'-1 1/2"12'-8 1/4"2'-7"CA 4.1CA 4.11A 4.01A 4.0#DrgID#LayID#DrgID#LayIDAA 4.0AA 4.0BA 3.4BA 3.4A#LayIDAt least 75% of all lamps in permanentlyinstalled fixtures are high efficacy.SURFACE MOUNT FLUORESCENT FIXTURESURFACE MOUNT FIXTUREHANGING FIXTURE (PENDANT/CHANDELIER)LAMPLED STRIP LIGHTSCONCERECESSED CAN - WET RATEDCLOSET LIGHTLIGHTING LEGENDRECESSED CAN LIGHTFLOOR OUTLETWALL OUTLETFIRE/CARBON MONOXIDE DETECTORCEILING FANFIXTURE COUNTSHigh efficacy fixtures: 96Non-high efficacy fixtures: 23% high efficacy fixtues: 76.1%ELEV. 7,860.22' =ARCH 95'-1 1/2"ELEV 7,865'- 1 1/8"ARCH 100'-0"DRYER VENTVENT HOODTHRU ROOFFP FLUE THRUROOFMECHEXHAUSTFROMBELOW22' TOPROPERTYLINE44' TOPROPERTYLINE64' TOPROPERTYLINE27' TOPROPERTYLINE23' TOPROPERTYLINETHROUGH ROOF32' TOPROPERTYLINEBA 3.4BA 3.455EEDD2A 5.02A 5.02A 5.00 2' 4' 8'SCALE: 1/4" = 1'-0"1PROPOSED MAIN LEVEL RCP Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 3.01/23/2019ELEVATIONS-EXISTINGDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/1876543211234567UNIT 2 SHOWN FOR REFERENCE7,379'-3 1/4' = ARCH 114'-2 1/8"0 2' 4' 8'SCALE: 1/4" = 1'-0"1NORTH ELEVATION - EXISTING0 2' 4' 8'SCALE: 1/4" = 1'-0"2SOUTH ELEVATION - EXISTING Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 3.11/23/2019ELEVATIONS-EXISTINGDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18FEDCBAFEEDCB3'-10" 5'-5"SCUPPER &DOWNSPOUT56437ABCDEF5'-6 1/2" 2'-11 1/2"0 2' 4' 8'SCALE: 1/4" = 1'-0"2WEST ELEVATION - EXISTING0 2' 4' 8'SCALE: 1/4" = 1'-0"1EAST ELEVATION - EXISTING Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 3.21/23/2019ELEVATIONS-PROPOSEDDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/1876543216'-6 1/2"9'-4 1/2"12'-11"15'-5"7'-9 1/2"22'-4 1/4"4'REBUILD AND ENLARGEEXISTING DECKREMOVE AND REPLACEROOF AND SLANTED WALLREMOVE VENEER, ADDSIDING AT GARAGEREINFORCE AND RESURFACEROOFREMOVE AND REPLACEROOF AND SLANTED WALLNEW DECK RAIL, HOLD BACKFROM WALLUNIT 2 SHOWN FORREFERENCE25' ABOVE GRADENEW WINDOWS, TYP.EXISTING AND PROPOSEDGRADENEW FLAT ROOFEXTEND EXISTING WALLSW34W05W06W27W36W35EXTEND CLOSET WALL FOR NEWENTRY ROOFEXIST'G CLOSETWALL & ROOFW25W31W32W33W26MAIN LEVEL7,865'- 1 1/8" = ARCH 100'-0EXISTING LOWER LEVEL7,856'-1 1/8' = ARCH 91'-0"T.O.WALL7,879'-3 1/4' = ARCH 114'-2 1/8"MAIN LEVEL7,867'- 10 1/8" = ARCH 112'-9VENTHOODFIREPLACEFLUE7,854'-9" = ARCH 89'-8"PROPOSED NEW LOWER SLAB123456722'-4 1/4"7'-9 1/2"15'-5"12'-11"9'-4 1/2"6'-6 1/2"REMOVE ANDREPLACE CHIIMNEYNEW WINDOWS IN NEWROOF AREAREMOVE VENEER FROM CARPORT, ADD SIDINGEXPANDED DECK WITH NEWRAILMASTER BEDROOM SLANTEDWALL REMOVED, BUILDPLUMB WALL TO NEW ROOFEXTENSIONMASTER BEDROOM SLANTEDWALL REMOVED, BUILDPLUMB WALL TO NEW ROOFEXTENSIONUNIT 2 SHOWN FORREFERENCEW2225' ABOVE GRADENEW DOOR TO GARAGE, U-VALUE 0.27DG1EXISTING AND PROPOSEDGRADEEXISTING ANDPROPOSED GRADEW25NEW FLAT ROOF OVERENTRY AND STAIRUNIT 2 SHOWN FOR REFERENCE7,379'-3 1/4' = ARCH 114'-2 1/8"ENTRY LEVEL7,860.22' = ARCH 95'-1 1/2"MAIN LEVEL7,865'- 1 1/8" = ARCH 100'-0LOWER LEVEL7,856'-1 1/8' = ARCH 91'-0"T.O.WALL7,879'-3 1/4' = ARCH 114'-2 1/8"7,854'-9" = ARCH 89'-8"PROPOSED NEW LOWER SLABSCALE: 1/4" = 1'-0"NORTH ELEVATION (SIDE YARD)SCALE: 1/4" = 1'-0"SOUTH ELEVATION (UNIT 2) Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 3.31/23/2019ELEVATIONS-PROPOSEDDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18ABCDEF2'-1 1/2"13'-1 3/4"8'-1 3/4"5'-10 1/4"11'-11 3/4"5'-6 1/2" 2'-11 1/2"REMOVE SLANTED WALLAND EXTEND ROOFREMOVE AND REPLACEEXISTING DOORS ANDWINDOWS, TYP.REMOVE STONE VENEER.INSTALL NEW GARAGEDOORS IN EXISTINGCARPORT OPENINGSFIELD VERIFY EXISTING ROOFPITCHW12D03D02D0125' HEIGHT LIMITEXISTING AND PROPOSEDGRADEW37NEW FLAT ROOF OVERENTRY AND STAIRSEXIST'G CLOSET ROOFEXTEND CLOSETWALLS TO NEW ROOFNEW ENTRY ROOF& COLUMNVENT HOOD BEYONDD06W28UNIT 2 FOR REFERENCE7,360.22'7,860.22' = ARCH 95'-1 1/2"7,865'- 1 1/8" = ARCH 100'-07,856'-1 1/8' = ARCH 91'-0"T.O.WALL7,877'-1 1/8" = ARCH 112'-0"7,870'- 7 5/8" = ARCH 105'-6 1/27,854'-9" = ARCH 89'-8"PROPOSED NEW LOWER SLAB21221217NEW ROOFEXISTING ROOFNEW ROOFEXISTING ROOF2FEDCBAFEEDCB3'-10" 5'-5"3'8'-11 3/4"3'5'-10 1/4"8'-1 3/4"13'-1 3/4"2'-1 1/2"REBUILD AND ENLARGEEXISTING DECKNEW DOORS ANDWINDOWS, TYP.ACCESS TO NEWUTILITY ROOMW02D40W03W18W14W1325' ABOVE GRADENEW UTILITY ROOMFOUNDATION, SEE STRUCT.FIREPLACE FLUEEXISTING AND PROPOSEDGRADEEXISTING GRADEPROPOSED GRADEW23D05W15NEW BEAM, SEE STRUCT.W24W29W29SCUPPER &DOWNSPOUTUNIT 2 FOR REFERENCEMAIN LEVEL7,865'- 1 1/8" = ARCH 100'-0LOWER LEVEL7,856'-1 1/8' = ARCH 91'-0"T.O.WALL7,879'-3 1/4' = ARCH 114'-2 1/8"T.O.WALLARCH 112'-11 3/8"T.O. ROOF7,873'- 0 1/8" = ARCH 107'-11T.O. WALLARCH 111'-10 1/2"MECHEXHAUSTMECHINTAKE7,854'-9" = ARCH 89'-8"PROPOSED NEW LOWER SLAB2122125643T.O. ROOFARCH 112'-6"7SCALE: 1/4" = 1'-0"WEST ELEVATION (STREET)SCALE: 1/4" = 1'-0"EAST ELEVATION (REAR) Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 3.41/23/2019ELEVATIONS-PROPOSEDHIDDENDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18 Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 4.01/23/2019SECTIONS -PROPOSEDDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18ABCDEF12A 5.0NEW EXTERIOR WALL. RE:5/A5.0 FOR ASSEMBLYNEW ROOF - RE: 9/A5.0 FORASSEMBLY & STRUCTURALMAIN LEVEL =7,865'- 1 1/8" = ARCH 100'-0CURRENT LOWER LEVEL =7,856'-1" = ARCH 91'-0"T.O.WALL7,877.1' = ARCH 112'-0"T.O.ROOF7,877.6' = ARCH 112'-6"PROPOSED LOWER LEVEL =7,854'-9" = ARCH 89'-4 5/8"1234567MAIN LEVEL7,865'- 1 1/8" = ARCH 100'-0CURRENT LOWER LEVEL7,856'-1 1/8' = ARCH 91'-0"T.O.PROPOSED WALL7,877'-2 1/8' = ARCH 112'-0"PROPOSED LOWER LEVEL7,854.5' = ARCH 89'-4 5/8"0 2' 4' 8'SCALE: 1/4" = 1'-0"1SECTION @ LIVINGNOT TO SCALESECTION @LIVING/DINING/KITCHEN Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 4.11/23/2019SECTIONS -PROPOSEDDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/182345677A 5.0MECH ROOM T.O. SLAB7,860.22' = ARCH 93'-6"MAIN LEVEL T.O. PLY7,865'- 1 1/8" = ARCH 100'-05'-6"NEW WALL - RE:5/A5.0 FORASSEMBLYNEW HALF-WALLWITH HANDRAILPER CODE AT STAIRSNEW ROOF PER STRUCTURAL.RE: 9/A5.0 FOR ASSEMBLY7,854'-9" = ARCH 89'-8"PROPOSED NEW LOWER SLABNEW MECH ROOM2EXIST'G SLAB LEVEL0 1' 2' 4'SCALE: 1/2" = 1'-0"1SECTION B MECH ROOM Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 5.01/23/2019DETAILSDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/185/8" GYPSUM WALL BOARD2x FLAT FURRING W/BLOWN IN INSULATION,REFERENCE PLANSCONCRETE FOUNDATIONWALL, RE: STRUCTURALWATERPROOFINGMEMBRANE2" BLUE BOARDINTERIOREXTERIOR5/8" GYPSUM WALL BOARDEXIST'G 2x4 FURRING w/MIN. R-15SPRAY FOAM INSUL - WRAP INSULOVER SILL PLATE TO EXTERIOR SHTG2x6 STUDS W/ 5 1/2" MINERALBATT INSULATION, R-19EXIST'G FOUNDATION WALL, ±6"ABOVE FINISHED EXTERIOR GRADEEXIST'G EXTERIOR WALL ASSEMBLYFINISHED EXTERIOR GRADE,EARTH OR CONCRETEINTERIOREXTERIOR9 1/4"0 1/2" 3 1/2" OR 5 1/2" 1" 1" 0 3/4"EXISTING AND NEW EXTERIOR SIDING FINISH,RE: ELEVATIONSINTERIOREXTERIOREXISTING 1/2" GWB TO BE REPLACED WITHNEW 5/8" GWB, RE: FLOOR PLANS ANDINTERIOR ELEVATIONSEXISTING BUILDING WRAP TO REMAINEXISTING EXTERIOR GRADE PLYWOODSHEATHING TO REMAIN, RE: STRUCT.NEW BATT INSULATION, R-21(EXISTING BATT INSULATION AT EXISTINGEXTERIOR WALLS TO REMAIN)NEW OR EXISTING WOOD FRAMING,RE: FLOOR PLANSEXISTING VAPOR BARRIER TO REMAINEXISTING 1" RIGID TO REMAINEXISTING DIMENSIONSNOTE: ALL PENETRATIONS TO BE SEALED WITHNON-EXPANDING SPRAY FOAM. HOUSE WRAPSEAMS AND EDGES TO BE TAPED PER MANUF.WALL-TO-FLOOR CONNECTIONS TO BE SET INBED OF SEALANTFLOOR ASSEMBLY, RE: FLOOR PLANVARIES1/8"2x FRAMING WITHSOUND BATT INSULATIONNOTE:EXISTING 2x FRAMING TO REMAINIF NO DEMOLITION REQUIRED,RE: FLOOR PLANSGWBPAINTED WOOD BASEBOARD (TILE SIM.)"J" METAL CORNER2" RIGID INSUL (R-5/INCH, MIN.)4" CONCRETE SLAB PER STRUCTURALUNDISTURBED EARTH4" WASHED GRAVEL6mil POLY VAPOR BARRIEREXTERIORINTERIORFINISHED FLOORFLOOR STRUCTURE, RE:STRUCTURAL PLANSBATT SOUND INSULATION3/4" SUBFLOOR PLYWOODCEILING FINISH, 5/8" GWB TYP.FINISHED FLOORINTERIORINTERIORBEAMS BEYOND -WRAP IN GYP BD3/4" CDX PLYRIGID INSULATION,TAPERED, R-10 MIN.TPO OR SIMILAR1/2" DENSDECKNEW SPRAY FOAMINSULATION, R-39 MIN.NEW GWB INTERIOR FINISHINTERIOREXTERIORSLOPERE: ROOF PLAN9"5/8" 5 1/2" 0 1/2" 1" 0 3/4"MIN. 6"NEW EXTERIOR SIDING FINISH,RE: ELEVATIONSINTERIOREXTERIORNEW 5/8" GWB, WALLS AND CEILING.PAINT. APPLY SHEAR PANEL ASREQUIRED BEHIND GWB RE:STRUCTURAL PLANS. SEAL ALLPENETRATIONSBUILDING WRAP, TAPE SEAMSEXISTING EXTERIOR GRADE PLYWOODSHEATHING TO REMAIN, RE: STRUCT.NEW BATT INSULATION, R-21NEW WOOD FRAMING,RE: FLOOR PLANSVAPOR BARRIER1" RIGID XPS, R 5/IN, SEAL GAPSSILL SEAL AT TREATED PLATE, TYP.SEAL SHEATHING TO FDN, TYP.METAL FLASHING, TYP.REINFORCED CONC. SLAB, SEE STRUCTSLOPE FOR DRAINAGE, TYP.NEW CONC. GRADE BEAM, RE: STRUCT.93'-8"WATERPROOFING AND DRAINAGE MATNEW 3" RIGID INSUL BELOW SLAB(TOTAL = R-15 PER RESCheck1 1/2" RIGID XPS, R 5/IN TO B.O.FND WALL, SEAL GAPS5/8" 5 1/2" 1/2" 1" 0 3/4"0 3/4"INTERIORNEW EXTERIOR SIDING FINISH,RE: ELEVATIONSEXTERIORNEW 5/8" GWB, WALLS AND CEILING.PAINT. APPLY SHEAR PANEL ASREQUIRED BEHIND GWB RE:STRUCTURAL PLANS. SEAL ALLPENETRATIONSBUILDING WRAP, TAPE SEAMSEXISTING EXTERIOR GRADE PLYWOODSHEATHING TO REMAIN, RE: STRUCT.NEW BATT INSULATION, R-21NEW WOOD FRAMING,RE: FLOOR PLANSVAPOR BARRIER1" RIGID XPS, R 5/IN, CONTINUOUS.SEAL GAPSSISTER 2X8S TO EXISTING JOISTSRE: STRUCTURAL PLANS. SEAL ALLPENETRATIONS w/CAULK, TYP.T&G WOOD SOFFIT OVER BUILDINGWRAP ON 1/2" SHEATHING ATOVERHANGSEAL SHEATHING TO RIM w/CAULK,TYP.R-30 MINERAL BATT INSUL2x FRAMING WITHMINERAL FIBER INSULATIONGWB IN UNIT 2 TO REMAINBASEBOARDRESILIENT CHANNELS 16" O.C.ATTACHED AT RIGHT ANGLESTO ONE SIDE OF WOOD STUDSWITH ONE LAYER 5/8" GWBAPPLIED AT RIGHT ANGLES TOCHANNELS. CAULK OR TAPESEAMSSIM. GA FILENO WP 3242ON A1.3 & A1.4CONTIN. 5/8" TYPE "X" GYP BDNOTE:EXISTING 2xFRAMING TO REMAINIF NO DEMOLITIONREQUIRED, RE:FLOOR PLANSADD'L LAYER OF 5/8" GYP BD,TEXTURE & PAINTEXIST'G ROOF MEMBRANE TO REMAINEXIST'G RIGID INSUL TO REMAIN -VERIFY DEPTH IN FIELDEXIST'G 1x6 T&G ROOF DECK TO REMAIN5/8" GYP BD, TEXTURE & PAINTBLOWN-IN CLOSED CELL FOAM INSUL. R-VALUE = 7/INCH. 5 1/2" REQUIREDRE:RESCheckLINE OF 2x4 CLG JSTS @ 24" o.c.INTERIOREXTERIORTYPICAL EXTERIOR WALL PER1x4 CASING - MATCH EXIST'GAT WINDOW HEAD: LAP HOUSEWRAP OVERWINDOW NAIL FINAT JAMB: LAP HOUSEWRAP INTO FRAMED OPENINGCAULK BEHIND NAIL FINSEAL HOUSEWRAP TO WINDOWFRAME w/BITUMEN TAPEFILL CAVITY WITH NON-EXPANDINGSPRAY FOAM INSULATIONALUMINUM CLAD WOODWINDOW PER RESCheckFILL CAVITY WITH NON-EXPANDINGSPRAY FOAM INSULATION1" x 1 1/2" WD NAILERFOLD HOUSEWRAP INTO OPENING1" x 1 1/2" WD NAILERSEAL WINDOW FRAME TO HOUSEWRAPw/BITUMEN TAPEMETAL FLASH'G - CAULK GAP TOWINDOW FRAME1x4 CASING - MATCH EXIST'GINTERIOREXTERIORHEAD &JAMBSILL0 3'' 6'' 9''SCALE: 3" = 1'-0"3TYPICAL FOUNDATION WALL0 3'' 6'' 9''SCALE: 3" = 1'-0"4TYPICAL EXTERIOR WALL @ STAIR WELL0 3'' 6'' 9''SCALE: 3" = 1'-0"5TYPICAL EXTERIOR WALL0 3'' 6'' 9''SCALE: 3" = 1'-0"6TYPICAL INTERIOR WALL0 3'' 6'' 9''SCALE: 3" = 1'-0"10TYPICAL INTERIOR SLAB ON GRADE0 3'' 6'' 9''SCALE: 3" = 1'-0"11TYPICAL FLOOR ASSEMBLY0 3'' 6'' 9''SCALE: 3" = 1'-0"9NEW CLASS A ROOF @ MASTER STE0 3'' 6'' 9''SCALE: 3" = 1'-0"7EXTERIOR WALL AT UTILITY ROOM0 3'' 6'' 9''SCALE: 3" = 1'-0"8EXTERIOR CANTILEVER WALL0 3'' 6'' 9''SCALE: 3" = 1'-0"2TYPICAL PARTITION WALL- STC0 3'' 6'' 9''SCALE: 3" = 1'-0"1LIVING/KITCHEN ROOF ASSEMBLY0 3'' 6'' 9''SCALE: 3" = 1'-0"12TYPICAL DOOR/WINDOW DETAIL Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 5.11/23/2019FIREPLACEDETAILSDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/186" 4"1'-11"MIN 2', V.I.F.T.O. LOWER LEVEL F.F.LIVING ROOM FIREPLACE SECTIONEL. + RE: FLOOR PLANEXISTING CMU TO REMAINEXISTING WOOD BURNING FIREPLACETO REMAINADD STEEL FRAME GLASS DOORSON FIREPLACEREPLACE STONE HEARTH VENEERAT SAME ELEVATION. EXIST'GSTRUCTURE TO REMAINREMOVE EXISTING STONE VENEERABOVE TO EXPOSE EXISTING FLUEPIPE; WRAP WITH DECORATIVE STEEL.MAINTAIN REQUIRED CLEARANCESNEW METAL CAP AND FLASHINGREPLACE FIREPLACE VENEERSTEEL ANGLE HEADERNEW STONE CAPFIELD-VERIFY EXIST'G HEARTHEXTENSION DURINGDEMOLITION. EXIST'G EXTENSIONTO REMAIN AS BUILT10"8'3'4"T.O. LOWER LEVEL F.F.#DrgID#LayID#DrgID#LayIDLIVING ROOM FIREPLACE INTERIOR ELEVATIONEL. + RE: FLOOR PLANREMOVE EXISTING STONE VENEER ABOVE TOEXPOSE EXISTING FLUE PIPE; WRAP WITHDECORATIVE STEELNEW GWB WALLNEW STEEL FRAME GLASS DOORSNEW STONE SURROUND AND HEARTHEXISTING WOOD BURNING FIREPLACEBEYOND TO REMAINNEW RAILING, STAIR BEYONDNEW SHELVING FOR WOOD STORAGENEW STONE CAP3'-4 1/2"8"1'-7"2"1'-6"1'-1"6"#DrgID#LayID#DrgID#LayIDLIVING ROOM FIREPLACE PLANSTONE HEARTHNEW STEEL FRAME GLASS DOORSEXISTING CMU TO REMAINEXISTING WOOD BURNING FIREPLACETO REMAINNEW STONE SURROUND0 6'' 1' 2'SCALE: 1" = 1'-0"3FIREPLACE0 6'' 1' 2'SCALE: 1" = 1'-0"2FIREPLACE0 6'' 1' 2'SCALE: 1" = 1'-0"1FIREPLACE Scale: AS NOTEDISSUESCHEMATIC DESIGNPERMIT SETVE SETZONING COMMENTS 1BUILDING COMMENTSPERMIT RESUBMITTALBUILDING COMMENTS 2BUILDING COMMENTS 3COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES.ALL DESIGNS, IDEAS ARRANGEMENTS ANDPLANS INDICATED BY THESE DRAWINGSAND SPECIFICATIONS ARE THE PROPERTYAND COPYRIGHT OF KIM RAYMONDARCHITECTS, INC. AND SHALL NEITHER BEUSED ON ANY OTHER WORK NOR BEUSED BY ANY OTHER PERSON FOR ANYUSE WHATSOEVER WITHOUT WRITTENPERMISSION. WRITTEN DIMENSIONSSHALL TAKE PRECEDENCE OVER SCALEDDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE. ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECT PRIORTO COMMENCEMENT OF WORK.A 6.01/23/2019SCHEDULESDATE1/24/18KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/187/30/188/14/189/27/1810/05/1811/15/1812/20/18W29W31W32W33W34W35W36W37xX4'×1'-5 1/2"4'×1'-5 1/2"5'-3 1/4"×1'-5 1/2"5'-3 1/4"×1'-5 1/2"4'-10 1/4"×1'-5 1/2"4'-10 1/2"×1'-5 1/2"4'×1'-5 1/2"4'×1'-5 1/2"7'×3'2'×3'-6"3'-6"3'-6"3'-6"3'-6"3'-6"3'-6"3'-7"48.50"48.50"63.75"63.75"58.75"59.00"48.50"48.50"84.50"24.50"Window ScheduleID TAGW02W03W05W06W11W12W13W14W15W17W18W22W23W24W25W25W26W27W28View from Opening SideNominal W x H Size4'-6"×4'-6"4'-6"×4'-6"5'×5'5'×5'4'×6'-4 1/4"5'×2'2'-6"×5'2'-6"×5'4'×5'2'×4'2'×3'-2"4'×6'-4 1/4"2'-6"×5'-3/4"4'×5'-3/4"4'×5'-3/4"4'×5'-3/4"4'×10'-6 1/4"4'-1 1/2"×8'-3/4"4'×2'-4 3/4"Sill Height3'-7"3'-7"3'-4"1'-9 1/4"5'-7 3/4"2'-0"2'-0"2'-0"3'-8"1'-9 1/4"3'-6"3'-6"3'-6"SquareFootage54.50"54.50"60.50"60.50"48.50"60.50"30.50"30.50"48.50"24.50"24.50"48.50"30.50"48.50"48.50"48.50"48.50"50.00"48.50"CommentsWindow ScheduleID TAGView from Opening SideNominal W x H SizeSill HeightSquareFootageCommentsDoor ScheduleID TAGD01D02D03D05D06D16D17D18D19D21D23D24D25D26View from Opening SideNominal Wx H Size8'×7'-6"8'×7'-6"3'×8'5'×8'15'-10 1/2"×7'-10 3/4"3'×7'2'-6"×6'-8"2'-6"×7'2'-2"×6'-8"2'-2"×7'1'-6"×6'-8"3'×6'-8"3'×6'-8"3'×6'-8"Door SF60.0060.0024.0039.99125.3121.0016.6717.5014.4415.1710.0020.0020.0020.00D26D31D32D33D34D35D36D37D38D40DG1XX3'×6'-8"2'×8'2'-4"×8'2'-6"×8'2'-4"×8'2'-6"×8'2'×8'5'×8'4'×8'3'×5'3'×6'-8"2'×6'-8"2'×6'-8"20.0016.0018.6720.0018.6720.0016.0040.0032.0015.0020.0013.3313.33Door ScheduleID TAGView from Opening SideNominal Wx H SizeDoor SFSAFETYGLAZINGREQUIREDSAFETYGLAZINGREQUIREDSAFETYGLAZINGREQUIREDNOTE: WINDOWS AND EXTERIOR DOORS MUST PROVIDE A MAXIMUM U-VALUEOF 0.32, PER RESCheck SPECIFICATIONS IN REPORT DATED 9/24/18 ANDSUBMITTED AS DOCUMENTATION FOR THE BUILDING PERMIT APPLICATIONSAFETYGLAZINGREQUIREDSAFETYGLAZINGREQUIRED