HomeMy WebLinkAboutFile Documents.950 Cemetery Ln.0152.2019 (6).ARBKScale: AS NOTED
ISSUE
SCHEMATIC DESIGN
PERMIT SET
VE SET
ZONING COMMENTS 1
BUILDING COMMENTS
PERMIT RESUBMITTAL
BUILDING COMMENTS 2
BUILDING COMMENTS 3
CONSTRUCTION SET
CHANGE ORDER 1COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUAL
IF THE ABOVE DIMENSION DOES
NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING WILL
HAVE BEEN ENLARGED OR
REDUCED, AFFECTING ALL
LABELED SCALES.
ALL DESIGNS, IDEAS ARRANGEMENTS AND
PLANS INDICATED BY THESE DRAWINGS
AND SPECIFICATIONS ARE THE PROPERTY
AND COPYRIGHT OF KIM RAYMOND
ARCHITECTS, INC. AND SHALL NEITHER BE
USED ON ANY OTHER WORK NOR BE
USED BY ANY OTHER PERSON FOR ANY
USE WHATSOEVER WITHOUT WRITTEN
PERM ISSION. W R ITTEN D IME NSIONS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS AND SHALL BE VERIFIED AT
T H E S I T E . A N Y D I M E N S I O N A L
DISCREPANCY SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT PRIOR
TO COMMENCEMENT OF WORK.
A 3.2
6/12/19
ELEVATIONS-
PROPOSED
DATE
1/24/18 KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/18
7/30/18
8/14/18
9/27/18
10/05/18
11/15/18
12/20/18
1/29/19
6/12/19
7 6 5 4 3 2 1
6'-6 1/2"9'-4 1/2"12'-11"15'-5"7'-9 1/2"22'-4 1/4"
4'
REBUILD AND ENLARGE
EXISTING DECK
REMOVE AND REPLACE
ROOF AND SLANTED WALL
REMOVE VENEER, ADD
CEMENT BOARD
RAINSCREEN AT GARAGE
REINFORCE AND RESURFACE
ROOF
REMOVE AND REPLACE
ROOF AND SLANTED WALL
NEW DECK RAIL, HOLD BACK
FROM WALL
UNIT 2 SHOWN FOR
REFERENCE
25' ABOVE GRADE
NEW WINDOWS, TYP.
EXISTING AND PROPOSED
GRADE
W34
W05 W06
W27
W36W35
EXTEND CLOSET WALL FOR NEW
ENTRY ROOF. ADD RAINSCREENEXIST'G CLOSET
WALL & ROOF
W25
W31 W32 W33
W26
NEW INSULATED DOOR
(MAX U-VALUE: .28)
MAIN LEVEL
7,865'- 1 1/8" = ARCH 100'-0
EXISTING LOWER LEVEL
7,856'-1 1/8' = ARCH 91'-0"
T.O.WALL
7,879'-3 1/4' = ARCH 114'-2 1/8"
MAIN LEVEL
7,867'- 10 1/8" = ARCH 112'-9
VENT
HOOD
7,854'-9" = ARCH 89'-8"
PROPOSED NEW LOWER SLAB
3A3.2
1 2 3 4 5 6 7
22'-4 1/4"7'-9 1/2"15'-5"12'-11"9'-4 1/2"6'-6 1/2"
EXISTING CHIMNEY TO
REMAIN. WRAP IN
CEMENT BOARD RAIN
SCREEN
NEW WINDOW
REMOVE VENEER FROM CARPORT, ADD
CEMENT BOARD RAINSCREEN
EXPANDED DECK WITH NEW
RAIL
MASTER BEDROOM SLANTED
WALL REMOVED, BUILD
PLUMB WALL TO NEW ROOF
EXTENSION
MASTER BEDROOM SLANTED
WALL REMOVED, BUILD
PLUMB WALL TO NEW ROOF
EXTENSION
UNIT 2 SHOWN FOR
REFERENCE
W22
25' ABOVE GRADE
NEW DOOR TO GARAGE, U-VALUE 0.27
DG1
EXISTING AND PROPOSED
GRADEEXISTING AND
PROPOSED GRADE
W25
NEW FLAT ROOF
EXTENSION OVER ENTRY
AND STAIR
ALIGN PANELS WITH WINDOW HEADER
AND ENTRY DOOR.
UNIT 2 SHOWN FOR REFERENCE
7,379'-3 1/4' = ARCH 114'-2 1/8"
ENTRY LEVEL
7,860.22' = ARCH 95'-1 1/2"
MAIN LEVEL
7,865'- 1 1/8" = ARCH 100'-0
LOWER LEVEL
7,856'-1 1/8' = ARCH 91'-0"
T.O.WALL
7,879'-3 1/4' = ARCH 114'-2 1/8"
7,854'-9" = ARCH 89'-8"
PROPOSED NEW LOWER SLAB
5/8"5 1/2"1/2"1 3/4"
INTERIOR
NEW CEMENT BOARD PANEL RAINSCREEN
SYSTEM. SEE EXTERIOR ELEVATIONS FOR
PANEL ALIGNMENT. ALL GAPS 3/8", TYP.
EXTERIOR
NEW 5/8" GWB, WALLS AND CEILING.
PAINT. APPLY SHEAR PANEL AS
REQUIRED BEHIND GWB RE:
STRUCTURAL PLANS. SEAL ALL
PENETRATIONS
WATERPROOF MEMBRANE
EXISTING EXTERIOR GRADE PLYWOOD
SHEATHING TO REMAIN, RE: STRUCT.
NEW BATT INSULATION, R-19
VERTICAL NAILERS AT 2' O.C. OR AS
NEEDED.
T&G WOOD SOFFIT OVER BUILDING
WRAP ON 1/2" SHEATHING AT
OVERHANG
SEAL SHEATHING TO RIM w/CAULK,
TYP.
1" RIGID XPS, R 5/IN, SEAL GAPS
A
A3.2
B
A3.2
C
A3.2
D
A3.2
E
A3.2
SCALE: 1/4" = 1'-0"1 NORTHWEST ELEVATION (SIDE YARD)
SCALE: 1/4" = 1'-0"2 SOUTHEAST ELEVATION
SCALE: 3" = 1'-0"3 RAINSCREEN DETAIL AT CORNER
If the non-conforming
portion of the existing
deck; which
encroaches into the
rear yard setback, is
removed, it cannot be
rebuilt within the
setback.
Please provide
updated demolition
calculations.