Loading...
HomeMy WebLinkAboutFile Documents.950 Cemetery Ln.0152.2019 (6).ARBKScale: AS NOTED ISSUE SCHEMATIC DESIGN PERMIT SET VE SET ZONING COMMENTS 1 BUILDING COMMENTS PERMIT RESUBMITTAL BUILDING COMMENTS 2 BUILDING COMMENTS 3 CONSTRUCTION SET CHANGE ORDER 1COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERM ISSION. W R ITTEN D IME NSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED AT T H E S I T E . A N Y D I M E N S I O N A L DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A 3.2 6/12/19 ELEVATIONS- PROPOSED DATE 1/24/18 KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/18 7/30/18 8/14/18 9/27/18 10/05/18 11/15/18 12/20/18 1/29/19 6/12/19 7 6 5 4 3 2 1 6'-6 1/2"9'-4 1/2"12'-11"15'-5"7'-9 1/2"22'-4 1/4" 4' REBUILD AND ENLARGE EXISTING DECK REMOVE AND REPLACE ROOF AND SLANTED WALL REMOVE VENEER, ADD CEMENT BOARD RAINSCREEN AT GARAGE REINFORCE AND RESURFACE ROOF REMOVE AND REPLACE ROOF AND SLANTED WALL NEW DECK RAIL, HOLD BACK FROM WALL UNIT 2 SHOWN FOR REFERENCE 25' ABOVE GRADE NEW WINDOWS, TYP. EXISTING AND PROPOSED GRADE W34 W05 W06 W27 W36W35 EXTEND CLOSET WALL FOR NEW ENTRY ROOF. ADD RAINSCREENEXIST'G CLOSET WALL & ROOF W25 W31 W32 W33 W26 NEW INSULATED DOOR (MAX U-VALUE: .28) MAIN LEVEL 7,865'- 1 1/8" = ARCH 100'-0 EXISTING LOWER LEVEL 7,856'-1 1/8' = ARCH 91'-0" T.O.WALL 7,879'-3 1/4' = ARCH 114'-2 1/8" MAIN LEVEL 7,867'- 10 1/8" = ARCH 112'-9 VENT HOOD 7,854'-9" = ARCH 89'-8" PROPOSED NEW LOWER SLAB 3A3.2 1 2 3 4 5 6 7 22'-4 1/4"7'-9 1/2"15'-5"12'-11"9'-4 1/2"6'-6 1/2" EXISTING CHIMNEY TO REMAIN. WRAP IN CEMENT BOARD RAIN SCREEN NEW WINDOW REMOVE VENEER FROM CARPORT, ADD CEMENT BOARD RAINSCREEN EXPANDED DECK WITH NEW RAIL MASTER BEDROOM SLANTED WALL REMOVED, BUILD PLUMB WALL TO NEW ROOF EXTENSION MASTER BEDROOM SLANTED WALL REMOVED, BUILD PLUMB WALL TO NEW ROOF EXTENSION UNIT 2 SHOWN FOR REFERENCE W22 25' ABOVE GRADE NEW DOOR TO GARAGE, U-VALUE 0.27 DG1 EXISTING AND PROPOSED GRADEEXISTING AND PROPOSED GRADE W25 NEW FLAT ROOF EXTENSION OVER ENTRY AND STAIR ALIGN PANELS WITH WINDOW HEADER AND ENTRY DOOR. UNIT 2 SHOWN FOR REFERENCE 7,379'-3 1/4' = ARCH 114'-2 1/8" ENTRY LEVEL 7,860.22' = ARCH 95'-1 1/2" MAIN LEVEL 7,865'- 1 1/8" = ARCH 100'-0 LOWER LEVEL 7,856'-1 1/8' = ARCH 91'-0" T.O.WALL 7,879'-3 1/4' = ARCH 114'-2 1/8" 7,854'-9" = ARCH 89'-8" PROPOSED NEW LOWER SLAB 5/8"5 1/2"1/2"1 3/4" INTERIOR NEW CEMENT BOARD PANEL RAINSCREEN SYSTEM. SEE EXTERIOR ELEVATIONS FOR PANEL ALIGNMENT. ALL GAPS 3/8", TYP. EXTERIOR NEW 5/8" GWB, WALLS AND CEILING. PAINT. APPLY SHEAR PANEL AS REQUIRED BEHIND GWB RE: STRUCTURAL PLANS. SEAL ALL PENETRATIONS WATERPROOF MEMBRANE EXISTING EXTERIOR GRADE PLYWOOD SHEATHING TO REMAIN, RE: STRUCT. NEW BATT INSULATION, R-19 VERTICAL NAILERS AT 2' O.C. OR AS NEEDED. T&G WOOD SOFFIT OVER BUILDING WRAP ON 1/2" SHEATHING AT OVERHANG SEAL SHEATHING TO RIM w/CAULK, TYP. 1" RIGID XPS, R 5/IN, SEAL GAPS A A3.2 B A3.2 C A3.2 D A3.2 E A3.2 SCALE: 1/4" = 1'-0"1 NORTHWEST ELEVATION (SIDE YARD) SCALE: 1/4" = 1'-0"2 SOUTHEAST ELEVATION SCALE: 3" = 1'-0"3 RAINSCREEN DETAIL AT CORNER If the non-conforming portion of the existing deck; which encroaches into the rear yard setback, is removed, it cannot be rebuilt within the setback. Please provide updated demolition calculations.