HomeMy WebLinkAboutFile Documents.950 Cemetery Ln.0152.2019 (7).ARBKScale: AS NOTED
ISSUE
SCHEMATIC DESIGN
PERMIT SET
VE SET
ZONING COMMENTS 1
BUILDING COMMENTS
PERMIT RESUBMITTAL
BUILDING COMMENTS 2
BUILDING COMMENTS 3
CONSTRUCTION SET
CHANGE ORDER 1COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUAL
IF THE ABOVE DIMENSION DOES
NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING WILL
HAVE BEEN ENLARGED OR
REDUCED, AFFECTING ALL
LABELED SCALES.
ALL DESIGNS, IDEAS ARRANGEMENTS AND
PLANS INDICATED BY THESE DRAWINGS
AND SPECIFICATIONS ARE THE PROPERTY
AND COPYRIGHT OF KIM RAYMOND
ARCHITECTS, INC. AND SHALL NEITHER BE
USED ON ANY OTHER WORK NOR BE
USED BY ANY OTHER PERSON FOR ANY
USE WHATSOEVER WITHOUT WRITTEN
PERM ISSION. W R ITTEN D IME NSIONS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS AND SHALL BE VERIFIED AT
T H E S I T E . A N Y D I M E N S I O N A L
DISCREPANCY SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT PRIOR
TO COMMENCEMENT OF WORK.
A 3.3
6/12/19
ELEVATIONS-
PROPOSED
DATE
1/24/18 KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/18
7/30/18
8/14/18
9/27/18
10/05/18
11/15/18
12/20/18
1/29/19
6/12/19
A B C D E F
2'-1 1/2"13'-1 3/4"8'-1 3/4"6'-1 1/4"11'-8 3/4"5'-6 1/2"REMOVE SLANTED WALL
AND EXTEND ROOF
R E M O V E A N D R E P L A C E
E X I S T I N G D O O R S A N D
WINDOWS, TYP.
REMOVE STONE VENEER.
INSTALL NEW GARAGE
DOORS IN EXISTING
CARPORT OPENINGS
W12
D03
D02D01
25' HEIGHT LIMIT
EXISTING AND PROPOSED
GRADE
W37
VENT HOOD BEYOND
D06
EXISTING CHIMNEY WITH
CEMENT BOARD RAIN
SCREEN
EXISTING CLOSET ROOF TO
BE OVERFRAMED AND
EXTENDED
EXTEND FRAMING OVER
GARAGE ROOF. NEW
CEMENT BD. RAINSCREEN
UNIT 2 FOR REFERENCE
7,360.22'7,860.22' = ARCH 95'-1 1/2"
7,865'- 1 1/8" = ARCH 100'-0
7,856'-1 1/8' = ARCH 91'-0"
T.O.WALL
7,877'-1 1/8" = ARCH 112'-0"
7,870'- 7 5/8" = ARCH 105'-6 1/2
7,854'-9" = ARCH 89'-8"
PROPOSED NEW LOWER SLAB
2
12
2
12
1
NEW ROOF
EXISTING ROOF
NEW ROOF
EXISTING ROOF
A
3'-10"5'-5"REBUILD AND ENLARGE
EXISTING DECK
NEW DOORS AND
WINDOWS, TYP.
ACCESS TO NEW
UTILITY ROOM
W02D40 W03
W18
W14W13
25' ABOVE GRADE
NEW UTILITY ROOM
FOUNDATION, SEE STRUCT.
EXISTING CHIMNEY WITH
NEW RAINSCREEN
EXISTING AND PROPOSED
GRADE
EXISTING GRADE
PROPOSED GRADE
W23
D05W15
NEW BEAM, SEE STRUCT.
W24
W29W29
GUTTER &
DOWNSPOUT
CRICKET BEYOND
UNIT 2 FOR REFERENCE
MAIN LEVEL
7,865'- 1 1/8" = ARCH 100'-0
LOWER LEVEL
7,856'-1 1/8' = ARCH 91'-0"
T.O.WALL
7,879'-3 1/4' = ARCH 114'-2 1/8"
T.O.WALL
ARCH 112'-11 3/8"
T.O. ROOF
7,873'- 0 1/8" = ARCH 107'-11
T.O. WALL
ARCH 111'-10 1/2"
MECH
EXHAUST
MECH
INTAKE
7,854'-9" = ARCH 89'-8"
PROPOSED NEW LOWER SLAB
2
12
2
12
T.O. ROOF
ARCH 112'-6"
D
A3.3
A
A3.3
C
A3.3
B
A3.3
SCALE: 1/4" = 1'-0"1 SOUTHWEST ELEVATION (STREET)
SCALE: 1/4" = 1'-0"2 NORTHEAST ELEVATION (REAR)
If the non-conforming
portion of the existing
deck; which
encroaches into the
rear yard setback, is
removed, it cannot be
rebuilt within the
setback.