Loading...
HomeMy WebLinkAboutFile Documents.950 Cemetery Ln.0152.2019 (7).ARBKScale: AS NOTED ISSUE SCHEMATIC DESIGN PERMIT SET VE SET ZONING COMMENTS 1 BUILDING COMMENTS PERMIT RESUBMITTAL BUILDING COMMENTS 2 BUILDING COMMENTS 3 CONSTRUCTION SET CHANGE ORDER 1COSTANZA REMODEL950 CEMETERY LANE, UNIT 1ASPEN, CO 816111" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERM ISSION. W R ITTEN D IME NSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED AT T H E S I T E . A N Y D I M E N S I O N A L DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A 3.3 6/12/19 ELEVATIONS- PROPOSED DATE 1/24/18 KIM RAYMOND ARCHITECTS, INC.| 300 E. HYMAN AVENUE, SUITE 100 || www.kimraymondarchitects.com || 970-925-2252 |4/2/18 7/30/18 8/14/18 9/27/18 10/05/18 11/15/18 12/20/18 1/29/19 6/12/19 A B C D E F 2'-1 1/2"13'-1 3/4"8'-1 3/4"6'-1 1/4"11'-8 3/4"5'-6 1/2"REMOVE SLANTED WALL AND EXTEND ROOF R E M O V E A N D R E P L A C E E X I S T I N G D O O R S A N D WINDOWS, TYP. REMOVE STONE VENEER. INSTALL NEW GARAGE DOORS IN EXISTING CARPORT OPENINGS W12 D03 D02D01 25' HEIGHT LIMIT EXISTING AND PROPOSED GRADE W37 VENT HOOD BEYOND D06 EXISTING CHIMNEY WITH CEMENT BOARD RAIN SCREEN EXISTING CLOSET ROOF TO BE OVERFRAMED AND EXTENDED EXTEND FRAMING OVER GARAGE ROOF. NEW CEMENT BD. RAINSCREEN UNIT 2 FOR REFERENCE 7,360.22'7,860.22' = ARCH 95'-1 1/2" 7,865'- 1 1/8" = ARCH 100'-0 7,856'-1 1/8' = ARCH 91'-0" T.O.WALL 7,877'-1 1/8" = ARCH 112'-0" 7,870'- 7 5/8" = ARCH 105'-6 1/2 7,854'-9" = ARCH 89'-8" PROPOSED NEW LOWER SLAB 2 12 2 12 1 NEW ROOF EXISTING ROOF NEW ROOF EXISTING ROOF A 3'-10"5'-5"REBUILD AND ENLARGE EXISTING DECK NEW DOORS AND WINDOWS, TYP. ACCESS TO NEW UTILITY ROOM W02D40 W03 W18 W14W13 25' ABOVE GRADE NEW UTILITY ROOM FOUNDATION, SEE STRUCT. EXISTING CHIMNEY WITH NEW RAINSCREEN EXISTING AND PROPOSED GRADE EXISTING GRADE PROPOSED GRADE W23 D05W15 NEW BEAM, SEE STRUCT. W24 W29W29 GUTTER & DOWNSPOUT CRICKET BEYOND UNIT 2 FOR REFERENCE MAIN LEVEL 7,865'- 1 1/8" = ARCH 100'-0 LOWER LEVEL 7,856'-1 1/8' = ARCH 91'-0" T.O.WALL 7,879'-3 1/4' = ARCH 114'-2 1/8" T.O.WALL ARCH 112'-11 3/8" T.O. ROOF 7,873'- 0 1/8" = ARCH 107'-11 T.O. WALL ARCH 111'-10 1/2" MECH EXHAUST MECH INTAKE 7,854'-9" = ARCH 89'-8" PROPOSED NEW LOWER SLAB 2 12 2 12 T.O. ROOF ARCH 112'-6" D A3.3 A A3.3 C A3.3 B A3.3 SCALE: 1/4" = 1'-0"1 SOUTHWEST ELEVATION (STREET) SCALE: 1/4" = 1'-0"2 NORTHEAST ELEVATION (REAR) If the non-conforming portion of the existing deck; which encroaches into the rear yard setback, is removed, it cannot be rebuilt within the setback.