HomeMy WebLinkAboutFile Documents.287 McSkimming Rd.0044.2018 (12).ARBKAir System Sizing Summary for Whole House Project Name: 17009 - McSkimming 04/20/2017 Prepared by: Rader Engineering 05:31PM Air System Information Air System Name Whole House Equipment Class UNDEF Air System Type SZCAV Number of zones 1 Floor Area 5718.0 ft² Location Aspen, Colorado Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone CFM Sizing Peak zone sensible load Space CFM Sizing Coincident space loads Central Cooling Coil Sizing Data Total coil load 8.8 Tons Total coil load 105.1 MBH Sensible coil load 102.1 MBH Coil CFM at Jul 1700 6629 CFM Max block CFM 6629 CFM Sum of peak zone CFM 6629 CFM Sensible heat ratio 0.971 ft²/Ton 652.6 BTU/(hr·ft²)18.4 Water flow @ 10.0 °F rise 21.04 gpm Load occurs at Jul 1700 OA DB / WB 86.4 / 64.0 °F Entering DB / WB 76.3 / 61.7 °F Leaving DB / WB 57.0 / 55.6 °F Coil ADP 54.9 °F Bypass Factor 0.100 Resulting RH 48 % Design supply temp.55.0 °F Zone T-stat Check 1 of 1 OK Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil load 120.4 MBH Coil CFM at Des Htg 6629 CFM Max coil CFM 6629 CFM Water flow @ 20.0 °F drop 12.04 gpm Load occurs at Des Htg BTU/(hr·ft²)21.1 Ent. DB / Lvg DB 68.7 / 91.5 °F Humidifier Sizing Data Max steam flow at Des Htg 6.22 lb/hr Airflow Rate 6629 CFM Air mass flow 22071.34 lb/hr Moisture gain .00028 lb/lb Supply Fan Sizing Data Actual max CFM 6629 CFM Standard CFM 4905 CFM Actual max CFM/ft²1.16 CFM/ft² Fan motor BHP 0.91 BHP Fan motor kW 0.72 kW Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/ft²0.00 CFM/ft² CFM/person 0.00 CFM/person Hourly Analysis Program v5.00 Page 1 of 2 5/1/17 Received 5/02/2017 12:40:38 PM Zone Sizing Summary for Whole House Project Name: 17009 - McSkimming 04/20/2017 Prepared by: Rader Engineering 05:31PM Air System Information Air System Name Whole House Equipment Class UNDEF Air System Type SZCAV Number of zones 1 Floor Area 5718.0 ft² Location Aspen, Colorado Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone CFM Sizing Peak zone sensible load Space CFM Sizing Coincident space loads Zone Terminal Sizing Data Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft² Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Whole House 6629 6629 1.16 0.0 0.00 0.0 0.00 0 Zone Peak Sensible Loads Zone Zone Zone Cooling Time of Heating Floor Sensible Peak Sensible Load Area Zone Name (MBH)Cooling Load (MBH)(ft²) Whole House 105.9 Jul 1600 125.8 5718.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft²) Space CFM/ft² Whole House 001-Flex 1 6.2 Jul 1600 391 9.7 959.0 0.41 004-Media 1 1.9 Jul 1600 118 2.8 242.0 0.49 005-Bunkroom 1 2.8 Jul 1600 177 5.7 394.0 0.45 006-Bunk Bath 1 1.2 Jul 1600 77 0.8 115.0 0.67 008-Bed 1 1 3.9 Jul 1600 245 6.1 222.0 1.10 009-Spa Bath 1 1.9 Jul 1600 121 1.8 180.0 0.67 010-Laundry 1 2.3 Jul 1600 143 0.7 73.0 1.96 100-Living/Entry 1 12.5 Jul 1600 779 15.8 662.0 1.18 101-Stair Tower 1 2.9 Jul 1600 182 3.5 104.0 1.75 102-Kitchen/Dining 1 19.7 Jul 1600 1231 16.2 676.0 1.82 106-Master Bed 1 11.9 Jul 1600 746 11.9 255.0 2.93 108-Master Bath 1 4.7 Jul 1600 295 5.0 150.0 1.97 110-Powder 1 0.4 Jul 1600 26 0.1 39.0 0.67 111-Study 1 6.2 Jul 1600 390 6.3 157.0 2.49 112-Hall 3 1 2.8 Jul 1600 177 3.0 60.0 2.96 113-Guest Master Bed 1 7.5 Jul 1600 472 8.8 261.0 1.81 114-Guest Master Bath 1 1.9 Jul 1600 119 1.6 118.0 1.01 115-Gear 1 0.9 Jul 1600 56 2.0 120.0 0.47 117-Mudroom 1 1.3 Jul 1600 81 2.3 147.0 0.55 118-Garage 1 4.2 Jul 1600 263 12.5 502.0 0.52 201-Bed 2 1 7.3 Jul 1600 459 8.3 227.0 2.02 202-Bath 2 1 1.2 Jul 1600 78 1.0 55.0 1.41 Hourly Analysis Program v5.00 Page 2 of 2 Received 5/02/2017 12:40:38 PM