Loading...
HomeMy WebLinkAboutFile Documents.310 W Bleeker St.0296.2018 (3).ARBK Page 1 of 5 REV. DATE DESCRIPTION 1 11/15/2018 CHANGED ELEVATOR LAYOUT & HOISTWAY DIMS ROCKY MOUNTAIN ELEVATOR PRODUCTS ELEVATORS MRL-950 RESIDENTIAL ELEVATOR LAYOUT DRAWING SUBMITTAL 2 STOP DEALER NAME: DEALER #: JOB NAME: ADDRESS ASSIGNED JOB S/N: DRAWN BY: PRELIMINARY DATE: APPROVED AS DRAWN - NO CHANGES: APPROVED DATE: REVISE WITH CHANGES NOTED: DATE: APPROVED WITH CHANGES NOTED: APPROVED DATE: COLORADO CUSTOM ELEVATOR & LIFT CO-001 BLEVINS RESIDENCE 310 W. BLEEKER ASPEN, CO 81611 _______________ KDC 10/31/2018 _______________ ________ _______________ _______________ ________ ________ PRELIMINARY Phone: (970) 242-2544 www.Rockymountainelevatorproducts.com 12/21/2018 DRAWN BY: TITLE: DATE:CONTRACTOR NAME: JOB NAME: DRAWING # APPROVED BY ELEVATOR DEALER:DATE: Phone: (970) 242-2544 www.Rockymountainelevatorproducts.com KDC ENGINEERING SPEC SHEET 10/31/2018 BLEVINS RESIDENCE PG 2 OF 5 ELEVATIONS RESIDENTIAL ELEVATOR ENGINEERING SPECIFICATION SHEET THESE DRAWINGS REFLECT OUR INTPRETATION OF THE INFORMATION THAT HAS BEEN PROVIDED. AFTER REVIEW, PLEASE CHECK THE APPROPRIATE BOX AND SIGN TO AUTHORIZE COMPLETION OF THIS ORDER. SPECIFICATION *MODEL: MRL-950 *LAYOUT: OPPOSITE *STOPS: 2 *RATED CAPACITY:950 LBS. *HOISTWAY ELEVATION: SEE PAGE 5 HOISTWAY LAYOUT: SEE PAGE 3 DRIVE SYSTEM *TYPE: ROPED HYDRALUIC (2:1) *MOTOR: 3HP AC, SINGLE PHASE, 208-230V, 1733 R.P.M., F.L. AMP 20.2 *SPEED: 40 FEET PER MINUTE *HOIST ROPES: (2) 3/8" DIA., 8x19 *JACK SIZE 70mm PUMP GPM: 6.2 *PRESSURES(PSI): NO LOAD - 399, FULL LOAD - 718, RELIEF - 897 *OIL REQ'D: 25 GAL TYPE AW32 *OIL LINE 3/4" DIA. x .063" WALL S.S. TUBING *PIPE RUPTURE VALVE: 1" NPT ELECTRICAL *MACHINERY: 230V SINGLE PHASE 30 AMP SERVICE[10-3 w/GROUND]. *CAR LIGHTS: 120V SINGLE PHASE 15 AMP SERVICE. SIGNAL VOLTAGE: 24 VDC *TELEPHONE: 24-48 VDC P.O.T.S. {PLAIN OLD TELEPHONE SYSTEM} OR C.O. (CENTRAL OFFICE) TOUCH TONE. V.O.I.P.(VOICE OVER INTERNET PROTOCOL) NOT RECOMMENDED, V.O.I.P. REQUIRES ANALOG LINE GENERATOR. NOTICE: THE KEY PAD PHONE PROVIDED WITH THIS LIFT IS INTENDED TO BE USED WITH AN ANALOG PHONE LINE CONNECTED TO A CENTRAL TELEPHONE EXCHANGE. THE PHONE WILL NOT OPPERATE WITH SOME MODEMS AND INTERNET SERVICE PROVIDERS. SAFETY FEATURES *TYPE'A' INSTANTANIOUS SAFETY BRAKES, BUFFERS-RUBBER. *FLOOR SELECTABLE BATTERY LOWERING, U.P.S. : 110V, 450VA. *EMERGENCY CAR LIGHTS, U.P.S.: 110V, 450VA. *EMERGENCY STOP & ALARM BELL. *EMERGENCY MANUAL LOWERING. STANDARD FEATURES *FULLY AUTOMATIC OPERATION: SINGLE SELECTIVE. *BI DIRECTIONAL LEVELING. *CAR LIGHT TIMER. *OVER/UNDER TRAVEL : 3" *SPEAKER TELEPHONE. *LIFT MEETS OR EXCEEDS THE REQUIREMENTS OF A17.1 2013 (PART5.3) WARNING FLAGS INFORMATION FLAGS OTHER OPTIONS * *(TBD-FINISHED NOT FINAL) (PRELIMINARY) APPROVED APPROVED AS NOTED NOT APPROVED ARCHITECT:__________________________ DATE:_________ GENERAL:___________________________ DATE:__________ OWNER/AGENT:______________________ DATE:__________ ALL APPLICABLE SIGNATURES REQUIRED 12/21/2018 Clear Gate Opening 34" PUMP UNIT Finished Hoistway Depth 5212"Clear Inside 36" 35" Door Center of Door 323 4" Center of Door 323 4" 35" Door Clear Inside 36" Clear Gate Opening 34"Clear Inside 4712"Platform 50"Platform 407 8" Finished Hoistway Width 563 8" (VERIFY ________)(VERIFY ________)(VERIFY ________) (VERIFY ________) FRONT Doors This Job: Example 3'0"x6'8" RH 1st 35" x 7'-0" LH (VERIFY ________) REAR Doors This Job: Example 3'0"x6'8" LH 2nd 35" x 7'-0" LH (VERIFY ________)To Centerline ofSupports 24"12"12"41 2" Rail C/L 101 2" C.T.W. REFER TO DETAIL A - A (BOTTOM FLOOR) DETAIL A - A 114" Car to Wall(Both Openings)2" Set Back TYPREV. DATE DESCRIPTION TRA11SRH-WGR,36x48,RR,FRONT,LH DRAWN BY: TITLE: DATE:CONTRACTOR NAME: JOB NAME: DRAWING # APPROVED BY ELEVATOR DEALER:DATE: Phone: (866) 482-4472 www.Rockymountainelevatorproducts.com KDC 10/31/2018 BLEVINS RESIDENCE PG 3 OF 5 1 11/15/18 CHANGED ELEVATOR LAYOUT AND HOISTWAY DIMS 12/21/2018 CAB & FIXTURE DESIGN SIGNATURE REQUIRED PRIOR TO PRODUCTION SPECIFICATION SHEET APPROVED APPROVED AS NOTED NOT APPROVED ARCHITECT:_________________________ DATE:__________ OWNER:___________________________ DATE:___________ OWNER/AGENT:_____________________ DATE:___________ PLEASE REVIEW THE INFORMATION AND FILL OUT ANY CHANGES TO YOUR CHOICES OF CAB FINISHES. *ALL DECISIONS NEED TO BE MADE NO LATER THAN 8 WEEKS PRIOR TO THE PUT IN PRODUCTION DATE. AFTER REVIEW, PLEASE CHECK THE APPROPRIATE BOX AND SIGN TO AUTHORIZE COMPLETION OF THIS ORDER. LIGHTING LIGHTING BY OTHERS: NO LIGHTS: RECESSED LED QTY: 2 FINISH: #4 BRUSHED S.S. C.O.P.: FIXTURE STYLE: STANDARD FIXTURE FINISH: #4 BRUSHED S.S. KEY LOCKOUT: NO HALL STATIONS: FIXTURE STYLE: STANDARD FIXTURE FINISH: ORB DIGITAL PI: NO KEY LOCKOUT: NO HANDRAIL: YES METAL STYLE: FLAT METAL FINISH: #4 BRUSHED S.S. INTERLOCKS SMARTLOCK (G.L.) INTERLOCK FINISH: S.S. QTY - LH: 1 RH: 1 *CANNOT MATCH LOCKS TO FIXTURES ON 2 & 3 SPEED SYSTEMS* FLOORING (By OTHERS): FLOORING TYPE: HARDWOOD FLOOR THICKNESS: 3/4" ASSEMBLY SPECIAL REQUESTS: (PRELIMINARY) CAB DETAILS LAYOUT: OPPOSITE CLEAR INSIDE: 36" x 47-1/2" CAB HEIGHT: 7'-0" DESIGN: ALUMINUM FRAMING HEADER: NONE MAIN WALL PANEL MATERIAL: EXTRUDED ALUMINUM MAIN WALL PANEL FINISH: MILL ALUMINUM MAIN WALL INSERT MATERIAL: TEMPERED GLASS MAIN WALL INSERT FINISH: CLEAR RAIL WALL PANEL MATERIAL: EXTRUDED ALUMINUM RAIL WALL PANEL FINISH: MILL ALUMINUM RAIL WALL INSERT MATERIAL: TEMPERED GLASS RAIL WALL INSERT FINISH: CLEAR CEILING MATERIAL: S.S. OVERLAY CEILING FINISH: #4 FINISH CEILING INSERT MATERIAL: TEMPERED GLASS CEILING INSERT FINISH: CLEAR ACRYLIC SKYLIGHT GATE DETAILS - FRONT TYPE: WRAP-AROUND # OF PANELS: 4 HEIGHT: 7'-0" WIDTH: 35" STACK: RH PANELS: TEMPERED GLASS FINISH: NICKEL GATE DETAILS - REAR TYPE: WRAP-AROUND # OF PANELS: 4 HEIGHT: 7'-0" WIDTH: 35" STACK: LH PANELS: TEMPERED GLASS FINISH: NICKEL SILL FINISH:GREY UHMW HOISTWAY DOORS: FRAMELESS GLASS SWING (BY OTHERS) GATE OPERATOR: YES QTY: LH: 1 RH: 1 *GATE OPERATORS INCLUDED WITH 2 & 3 SPEED SYSTEMS* CAB & FIXTURE DESIGN DRAWN BY: TITLE: DATE:CONTRACTOR NAME: JOB NAME: DRAWING # APPROVED BY ELEVATOR DEALER:DATE: Phone: (970) 242-2544 www.Rockymountainelevatorproducts.com KDC 10/31/2018 PG 4 OF 5 BLEVINS RESIDENCE 12/21/2018 2 STOP RR HOISTWAY ELEVATION DRAWN BY: TITLE: DATE:CONTRACTOR NAME: JOB NAME: DRAWING # APPROVED BY ELEVATOR DEALER:DATE: Phone: (970) 242-2544 www.Rockymountainelevatorproducts.com KDC 10/31/2018 PG 5 OF 5 BLEVINS RESIDENCEOPENING HEIGHT (SEE PAGE 4)CLEAR INSIDE CAB HEIGHT (SEE PAGE 4)CLEAR OVERHEAD ** 108"TRAVEL 120"OVERALL HOISTWAY 238"PEDESTALLENGTH_______PROJECTIONWHEN ROPING _______RAMSHEAD 15"COLLAPSED CYLINDER LENGTH _______PISTON STROKE ________OVERALL EQUIPMENT HEIGHT __________CLEAR_____PIT DEPTH * 10"1 2 (**) MINIMUM CLEAR OVERHEAD 7'0" Cab = 8'0" Clear Overhead 8'0" Cab = 9'0" Clear Overhead *MORE SPACE IS DESIRABLE LANDING LOCATION CHART NOTE: Travel from landing to landing must be at least 20"TOTAL RAIL LENGTH ________RAIL BRACKET SPACING CHART (VERIFY ________)(VERIFY ________)(VERIFY ________)FRONTA B CABOVERHEAD_______*SEE PAGE 6 FOR PIT DEPTH RECOMMENDATIONS* BRKT NO. ELEV. FROM PIT FLOOR 9 504" 8 444" 7 384" 6 324" 5 269" 4 204" 3 144" 2 84" 1 24" LANDING FRONT REAR SIDE 2 X 1X PEDESTAL BRACKET JACK BRACKET AB 12/21/2018 10" MIN. PIT DEPTH RECOMMENDED (Absolute Min. 8") 12"12" q- SEE PG 3 R1 R1 R4 R2 R3 Rail Forces R1 197 R2 280 R3 4625 R4 616 SUPPORT WALL OF WOOD OR FILLED CONCRETE BLOCK (4 total) 1-3/4"x9-1/2" (2x10) LAMINATED VENEER LUMBER (LVL) HEIGHT OF HOISTWAY IS USED TO ANCHOR RAIL BRACKETS TOP VIEW OF RAILS 2X4 STUD FRAMING GLUED AND SCREWED TO LVL's TO HOLD IN PLACE MUST BE GLUED AND SCREWED TOGETHER FINISHED HOISTWAY #4 REBAR 18" OC EACH WAY SINGLE MAT FRONT FINISHED DRYWALL FLUSH TO ALL PIT WALLS 1/2" or 5/8" TYPE X DRYWALL (Fire not required) 1/2" or 5/8" DRYWALL #4 VERT. & LATERAL 18" OC EW FINISHED SLAB 4"PIT FLOOR LOAD: IMPACT-- 4700# (950# CAPACITY) STATIC-- 2900# (950# CAPACITY)FINISHED HOISTWAYTOP VIEW OF PIT 2X4 TYPICAL (VERIFY ________) *SEE PAGE 3 FOR FINISHED PIT DIMENSIONS* *SEE PAGE 5 FOR THIS JOB* RAIL BRACKET ENLARGED VIEW SHOWING FASTENER HOLES 3116" 7716" PIT REACTIONS CAPACITY 950# LOAD ON JACK 4,275 LBS. LOAD ON BUFFERS 4,750 LBS. q- SEE PG 3 PIT LAYOUT & 12" CL LVL BACKING DRAWN BY: TITLE: DATE:CONTRACTOR NAME: DRAWING # APPROVED BY ELEVATOR DEALER:DATE: Phone: (970) 242-2544 www.Rockymountainelevatorproducts.com WLL 5/22/18 12/21/2018 DETAIL ASCALE 1 / 211223344AABBCCDDREVGLK-600000SCALEDWG NOSIZECGLASS EMI LAYOUT - SMARTLOCK GLTITLESHEET 1 OF 2 TOLERANCES ANGULAR: 1.XXX: ±.005 .XX: ±.015DRAWNMFGDO NOT SCALE DRAWINGAPPROVED4/8/2015WLLQACHECKEDANOTES: UNLESS OTHERWISE SPECIFIED.1. ALL GLASS (BY OTHERS) MUST BE LAMINATED (ASME A17.1 CODE 2.1.1.2.2(e)).2. ALL GLASS (BY OTHERS) MUST BE TEMPERED WITH A FINISHED THICKNESS OF 1/2".3. MUST BE BUILT IN ACCORDANCE TO ASME A17.1 CODE 5.3.1.1 AND CODE 5.3.1.7 (BY OTHERS).4. STRIKE WALL MUST HAVE MOUNTING POINTS WITHIN 2-4" OF THE LOCK CUTOUT.5. DOOR MUST HAVE A NON-GLASS EDGE GUARD. [ASME A17.1 CODE 2.11.7.2.4]6. DOOR/FRAME ASSY. MUST WITHSTAND 560 Lbs. OF FORCE OVER A 4" x 4" AREA WITHOUT CONSIDERABLE DEFLECTION [ASME A17.1 CODE 2.11.11.5.7]7. HINGES MUST NOT ALLOW THE DOOR TO PROTRUDE INTO THE HOISTWAY WHEN OPEN.8. HINGES MUST BE SELF CLOSING OR EQUIVALENT SYSTEM BY OTHERS.9. VERIFY MINIMUM STRIKE PANEL WIDTH WITH GLASS VENDOR.10. DOOR MUST BE A MINUMUM OF 3/8" ABOVE FINISHED FLOOR.11. PROVISIONS TO COVER OR HIDE THE LOCK WIRES ARE TO BE PERFORMED BY OTHERS.12. HANDLE HOLE SPACING 3.75" (96mm) CC.13. FINISH: BRUSHED STAINLESS STEELSTRIKE PANELDOORHINGE PANEL560 Lbs12/21/2018 DETAIL BSCALE 1 / 2DETAIL CSCALE 1 / 411223344AABBCCDDREVGLK-600000SCALEDWG NOSIZECGLASS EMI LAYOUT - SMARTLOCK GLTITLESHEET 2 OF 2 TOLERANCES ANGULAR: 1.XXX: ±.005 .XX: ±.015DRAWNMFGDO NOT SCALE DRAWINGAPPROVED4/8/2015WLLQACHECKEDBCBUILT-IN HALLCALL STATIONPULL HANDLE(EXTERIOR)LUNAR KEYACCESS PORT1.69.381.842.383.20.25 GAPS(TYP.).375MIN.2.00HOISTWAY SILLNOTES: UNLESS OTHERWISE SPECIFIED.1. SEE SHEET 1 FOR SPECIFICATIONS.2. HEIGHT DIMENSIONS ARE FROM FINISHED FLOOR.PULL HANDLE(INTERIOR)SILL LINEINTERIOR PULL HANDLE MUST NOTPROTRUDE PAST THE SILL LINE36.0031.321.37PRE WIRELOCATION40.31PRE WIRELOCATION.2511.75013.7503.0001.2506.8755.8752.251.000.250R.13(2) MAX4.004.00560 Lbs.750(2) .500(2) 12/21/2018 30" WIDE x 36" DEEP x 78" HIGH CLEAR SPACE IN FRONT OF CONTROLPANEL REQUIREDPHONE LINE (By Others) ELEVATOR CONTROL PANEL AS TO ELEC. SHOCK & FIRE ANSI-ASME A17.1 & CAN-CSA B44.1-ASME A17.1 48°-135° OPERATING TEMPERATURE CAR LIGHT DEDICATED CIRCUIT, 120 VAC, 15 AMP, 1 PHASE, 60 HZ. (By Others) 3 WIRE WITH GROUND (L1, L2, NEUTRAL, GROUND), #10 GAGE WIRE, 230VAC, 30 AMP, 1 PHASE, 60HZ. (By Others) * CONTROL PANEL TO BE LOCATED COMMON TO A SHAFT WALL. (ASK ABOUT ADDITIONAL CHARGES TO LOCATE THIS PANEL ELSEWHERE.)36" BOX HEIGHT4 3 4 " D E P T H W / D O O R 14-1 2" BOX WIDTH CONTROL PANEL *LOCKABLE DISCONNECTS/BREAKERS ARE BUILT INTO THE CONTROLLER RECESSED UNDER FRONT CABINET DOOR. 4' WHIPS CAR LIGHT BREAKER MOTOR/PUMP BREAKER 1.43810.20"10.00" 12.00"10.00"12.00"STANDARD FEATURES: SLOTTED SCREW CAM LATCH CARBON STEEL POWDER COAT WHITE FINISH OPTIONS: LOCK TYPE MATERIAL CYLINDER LOCK AND KEY STAINLESS STEEL ALLEN HEAD CAM LATCH #4 SATIN POLISH SPANNER HEAD CAM LATCH OTHER MRL CONTROLLER OPTIONAL MRL ACCESS PANEL MACHINE ROOM LAYOUT - MRL DRAWN BY: TITLE: DATE: CONTRACTOR NAME: DRAWING # APPROVED BY ELEVATOR DEALER: DATE: Phone: (970) 242-2544 www.Rockymountainelevatorproducts.com WLL 5/22/18 12/21/2018 WORK PERFORMED BY OTHERS DELIVERY 1. Provide smooth (roll-able) access as closely as possible to the installation area. HOISTWAY 1. Hoistway wall must be framed on each level from equipment shop drawings, not architectural drawings. (All dimensions are to finished wall). 2. Hoistway must be plumb and square within 1/4". 3. Hoistway doors must be installed on all floors/landings as per shop drawings. 4. Hoistways must be COMPLETELY enclosed without grillwork or openings. 5. Drywall and taping must be complete by time of install. 6. No other pipes, wires, liquids, gasses, etc. are allowed in hoistway by code. 7. Hoistway temperature must be maintained within 60 to 100 degrees Farenheit. 8. All glass must be minimum of 14" laminated safety glass with visible markings of applicable code. 9. All exterior windows must have metal grillwork that will reject a 3" ball. DOORS 1. Doors MUST comply with ASME A17.1 applicable code year (reference Mandatory Door Detail). 2. Doors accessing a garage landing must have a 1 hour fire rating. 3. The doors, hardware and closers (spring loaded hinges) are to be supplied and installed prior to installation. 4. Door openings must be laid out and framed per elevator shop drawings, not architectural drawings. PIT 1. Pit must be poured to proper depth and size (reference shop drawings). 2. Pits deeper than 35" must will require a pit ladder or false floor built to listed pit depth dimension. 3. A dry, clean pit must be maintained. MACHINE ROOM/EQUIPMENT CLOSET 1. Elevator/lift equipment may be placed in mechanical room with other equipment (water heater, furnace, etc.). If winding drum is not in a dedicated room with self-closing, self-locking door, alternate protection is required for drive and cables. 2. Must be within 40' of hoistway. Some areas may not be allowed, please consult us before construction. hoistway. 3. Must have a minimum of 3'0" clear area in front of controller as per electrical code. 4. Permanent telephone line to controller. Telephone line must be live before inspection. Cannot use V.O.I.P. phone system, cellular or wireless systems. Phone must work in a power outage. (V.O.I.P. Requires signed liability waiver). 5. Machine room temperature must be maintained within 60-100 degrees Fahrenheit. 6. 230V Single Phase service whip needs to be ran to Controller. (See page 2 for breaker size). 7. 120V 15Amp Single Phase dedicated car light service whip needs to be ran to Controller. CAB & FINISH 1. All cab choices and any materials being supplied for finishes of this elevator must be provided a minimum of 10 weeks prior to the installation of elevator. SAFETY 1. Hoistway doors must be installed and secured and/or OSHA approved removable barricades. STORAGE 1. A dry, clean, and secure area needs to be provided for the elevator equipment not installed at time of delivey. ACCEPTANCE/FINAL INSPECTION 1. The elevator phone with dial tone must be present prior to inspection. 2. Cab interior, door hardware, door trim, and door finishes must be complete prior to inspection. 3. The elevator cannot be turned over and/or used for construction until it has passed final inspection. THIS PAGE ALONG WITH THE ATTACHED HOISTWAY, CAB, PIT AND DOOR DETAIL DRAWINGS MUST BE SIGNED AND RETURNED. I HAVE READ AND UNDERSTAND ALL SITE REQUIREMENTS, INCLUDING THE HOISTWAY CONDITIONS FOR INSTALLATION. Company:_____________________________ Job:___________________________________ Owner/Agent:______________________________ Date:___________________________ WORK PERFORMED BY OTHERS DRAWN BY: TITLE: DATE: CONTRACTOR NAME: DRAWING # APPROVED BY ELEVATOR DEALER: DATE: Phone: (970) 242-2544 www.rockymountainelevatorproducts.com WLL 5/22/2018 12/21/2018