HomeMy WebLinkAboutFile Documents.310 W Bleeker St.0296.2018 (3).ARBK
Page 1 of 5
REV. DATE DESCRIPTION
1 11/15/2018 CHANGED ELEVATOR LAYOUT & HOISTWAY DIMS
ROCKY MOUNTAIN ELEVATOR PRODUCTS
ELEVATORS MRL-950 RESIDENTIAL ELEVATOR
LAYOUT DRAWING SUBMITTAL
2 STOP
DEALER NAME:
DEALER #:
JOB NAME:
ADDRESS
ASSIGNED JOB S/N:
DRAWN BY:
PRELIMINARY DATE:
APPROVED AS DRAWN - NO CHANGES:
APPROVED DATE:
REVISE WITH CHANGES NOTED:
DATE:
APPROVED WITH CHANGES NOTED:
APPROVED DATE:
COLORADO CUSTOM ELEVATOR & LIFT
CO-001
BLEVINS RESIDENCE
310 W. BLEEKER
ASPEN, CO 81611
_______________
KDC
10/31/2018
_______________
________
_______________
_______________
________
________
PRELIMINARY
Phone: (970) 242-2544
www.Rockymountainelevatorproducts.com
12/21/2018
DRAWN BY:
TITLE:
DATE:CONTRACTOR NAME:
JOB NAME:
DRAWING #
APPROVED BY ELEVATOR DEALER:DATE:
Phone: (970) 242-2544
www.Rockymountainelevatorproducts.com
KDC
ENGINEERING SPEC SHEET
10/31/2018
BLEVINS RESIDENCE
PG 2 OF 5
ELEVATIONS RESIDENTIAL ELEVATOR
ENGINEERING SPECIFICATION SHEET
THESE DRAWINGS REFLECT OUR INTPRETATION OF THE INFORMATION THAT HAS BEEN PROVIDED. AFTER
REVIEW, PLEASE CHECK THE APPROPRIATE BOX AND SIGN TO AUTHORIZE COMPLETION OF THIS ORDER.
SPECIFICATION
*MODEL: MRL-950
*LAYOUT: OPPOSITE
*STOPS: 2
*RATED CAPACITY:950 LBS.
*HOISTWAY ELEVATION: SEE PAGE 5 HOISTWAY LAYOUT: SEE PAGE 3
DRIVE SYSTEM
*TYPE: ROPED HYDRALUIC (2:1)
*MOTOR: 3HP AC, SINGLE PHASE, 208-230V, 1733 R.P.M., F.L. AMP 20.2
*SPEED: 40 FEET PER MINUTE
*HOIST ROPES: (2) 3/8" DIA., 8x19
*JACK SIZE 70mm PUMP GPM: 6.2
*PRESSURES(PSI): NO LOAD - 399, FULL LOAD - 718, RELIEF - 897
*OIL REQ'D: 25 GAL TYPE AW32
*OIL LINE 3/4" DIA. x .063" WALL S.S. TUBING
*PIPE RUPTURE VALVE: 1" NPT
ELECTRICAL
*MACHINERY: 230V SINGLE PHASE 30 AMP SERVICE[10-3 w/GROUND].
*CAR LIGHTS: 120V SINGLE PHASE 15 AMP SERVICE.
SIGNAL VOLTAGE: 24 VDC
*TELEPHONE: 24-48 VDC P.O.T.S. {PLAIN OLD TELEPHONE SYSTEM} OR C.O.
(CENTRAL OFFICE) TOUCH TONE. V.O.I.P.(VOICE OVER INTERNET PROTOCOL)
NOT RECOMMENDED, V.O.I.P. REQUIRES ANALOG LINE GENERATOR.
NOTICE: THE KEY PAD PHONE PROVIDED WITH THIS LIFT IS INTENDED TO BE USED WITH
AN ANALOG PHONE LINE CONNECTED TO A CENTRAL TELEPHONE EXCHANGE.
THE PHONE WILL NOT OPPERATE WITH SOME MODEMS
AND INTERNET SERVICE PROVIDERS.
SAFETY FEATURES
*TYPE'A' INSTANTANIOUS SAFETY BRAKES, BUFFERS-RUBBER.
*FLOOR SELECTABLE BATTERY LOWERING, U.P.S. : 110V, 450VA.
*EMERGENCY CAR LIGHTS, U.P.S.: 110V, 450VA.
*EMERGENCY STOP & ALARM BELL.
*EMERGENCY MANUAL LOWERING.
STANDARD FEATURES
*FULLY AUTOMATIC OPERATION: SINGLE SELECTIVE.
*BI DIRECTIONAL LEVELING.
*CAR LIGHT TIMER.
*OVER/UNDER TRAVEL : 3"
*SPEAKER TELEPHONE.
*LIFT MEETS OR EXCEEDS THE REQUIREMENTS OF A17.1 2013 (PART5.3)
WARNING FLAGS
INFORMATION FLAGS
OTHER OPTIONS
*
*(TBD-FINISHED NOT FINAL)
(PRELIMINARY)
APPROVED
APPROVED AS NOTED
NOT APPROVED
ARCHITECT:__________________________ DATE:_________
GENERAL:___________________________ DATE:__________
OWNER/AGENT:______________________ DATE:__________
ALL APPLICABLE SIGNATURES REQUIRED
12/21/2018
Clear Gate Opening 34"
PUMP
UNIT
Finished Hoistway Depth 5212"Clear Inside 36"
35" Door
Center of Door
323 4"
Center of Door
323 4"
35" Door
Clear Inside 36"
Clear Gate Opening 34"Clear Inside 4712"Platform 50"Platform 407 8"
Finished Hoistway Width 563 8"
(VERIFY ________)(VERIFY ________)(VERIFY ________)
(VERIFY ________)
FRONT
Doors This Job:
Example 3'0"x6'8" RH
1st 35" x 7'-0" LH
(VERIFY ________)
REAR
Doors This Job:
Example 3'0"x6'8" LH
2nd 35" x 7'-0" LH
(VERIFY ________)To Centerline ofSupports 24"12"12"41 2"
Rail C/L
101 2"
C.T.W.
REFER TO
DETAIL A - A
(BOTTOM FLOOR)
DETAIL A - A
114" Car to Wall(Both Openings)2" Set Back TYPREV. DATE DESCRIPTION
TRA11SRH-WGR,36x48,RR,FRONT,LH
DRAWN BY:
TITLE:
DATE:CONTRACTOR NAME:
JOB NAME:
DRAWING #
APPROVED BY ELEVATOR DEALER:DATE:
Phone: (866) 482-4472
www.Rockymountainelevatorproducts.com
KDC 10/31/2018
BLEVINS RESIDENCE
PG 3 OF 5
1 11/15/18 CHANGED ELEVATOR LAYOUT AND HOISTWAY DIMS
12/21/2018
CAB & FIXTURE DESIGN
SIGNATURE REQUIRED PRIOR TO PRODUCTION
SPECIFICATION SHEET
APPROVED
APPROVED AS NOTED
NOT APPROVED
ARCHITECT:_________________________ DATE:__________
OWNER:___________________________ DATE:___________
OWNER/AGENT:_____________________ DATE:___________
PLEASE REVIEW THE INFORMATION AND FILL OUT ANY CHANGES TO YOUR CHOICES OF CAB FINISHES.
*ALL DECISIONS NEED TO BE MADE NO LATER THAN 8 WEEKS PRIOR TO THE PUT IN PRODUCTION DATE.
AFTER REVIEW, PLEASE CHECK THE APPROPRIATE BOX AND SIGN TO AUTHORIZE COMPLETION OF THIS ORDER.
LIGHTING
LIGHTING BY OTHERS: NO
LIGHTS: RECESSED LED QTY: 2
FINISH: #4 BRUSHED S.S.
C.O.P.:
FIXTURE STYLE: STANDARD
FIXTURE FINISH: #4 BRUSHED S.S.
KEY LOCKOUT: NO
HALL STATIONS:
FIXTURE STYLE: STANDARD
FIXTURE FINISH: ORB
DIGITAL PI: NO
KEY LOCKOUT: NO
HANDRAIL: YES
METAL STYLE: FLAT
METAL FINISH: #4 BRUSHED S.S.
INTERLOCKS
SMARTLOCK (G.L.)
INTERLOCK FINISH: S.S.
QTY - LH: 1 RH: 1
*CANNOT MATCH LOCKS TO FIXTURES ON 2 & 3 SPEED SYSTEMS*
FLOORING (By OTHERS):
FLOORING TYPE: HARDWOOD
FLOOR THICKNESS: 3/4" ASSEMBLY
SPECIAL REQUESTS:
(PRELIMINARY)
CAB DETAILS
LAYOUT: OPPOSITE
CLEAR INSIDE: 36" x 47-1/2" CAB HEIGHT: 7'-0"
DESIGN: ALUMINUM FRAMING
HEADER: NONE
MAIN WALL PANEL MATERIAL: EXTRUDED ALUMINUM
MAIN WALL PANEL FINISH: MILL ALUMINUM
MAIN WALL INSERT MATERIAL: TEMPERED GLASS
MAIN WALL INSERT FINISH: CLEAR
RAIL WALL PANEL MATERIAL: EXTRUDED ALUMINUM
RAIL WALL PANEL FINISH: MILL ALUMINUM
RAIL WALL INSERT MATERIAL: TEMPERED GLASS
RAIL WALL INSERT FINISH: CLEAR
CEILING MATERIAL: S.S. OVERLAY
CEILING FINISH: #4 FINISH
CEILING INSERT MATERIAL: TEMPERED GLASS
CEILING INSERT FINISH: CLEAR ACRYLIC SKYLIGHT
GATE DETAILS - FRONT
TYPE: WRAP-AROUND # OF PANELS: 4
HEIGHT: 7'-0" WIDTH: 35" STACK: RH
PANELS: TEMPERED GLASS
FINISH: NICKEL
GATE DETAILS - REAR
TYPE: WRAP-AROUND # OF PANELS: 4
HEIGHT: 7'-0" WIDTH: 35" STACK: LH
PANELS: TEMPERED GLASS
FINISH: NICKEL
SILL FINISH:GREY UHMW
HOISTWAY DOORS: FRAMELESS GLASS SWING (BY OTHERS)
GATE OPERATOR: YES QTY: LH: 1 RH: 1
*GATE OPERATORS INCLUDED WITH 2 & 3 SPEED SYSTEMS*
CAB & FIXTURE DESIGN
DRAWN BY:
TITLE:
DATE:CONTRACTOR NAME:
JOB NAME:
DRAWING #
APPROVED BY ELEVATOR DEALER:DATE:
Phone: (970) 242-2544
www.Rockymountainelevatorproducts.com
KDC 10/31/2018
PG 4 OF 5
BLEVINS RESIDENCE 12/21/2018
2 STOP RR HOISTWAY ELEVATION
DRAWN BY:
TITLE:
DATE:CONTRACTOR NAME:
JOB NAME:
DRAWING #
APPROVED BY ELEVATOR DEALER:DATE:
Phone: (970) 242-2544
www.Rockymountainelevatorproducts.com
KDC 10/31/2018
PG 5 OF 5
BLEVINS RESIDENCEOPENING HEIGHT (SEE PAGE 4)CLEAR INSIDE CAB HEIGHT (SEE PAGE 4)CLEAR OVERHEAD ** 108"TRAVEL 120"OVERALL HOISTWAY 238"PEDESTALLENGTH_______PROJECTIONWHEN ROPING _______RAMSHEAD 15"COLLAPSED CYLINDER LENGTH _______PISTON STROKE ________OVERALL EQUIPMENT HEIGHT __________CLEAR_____PIT DEPTH * 10"1
2
(**) MINIMUM CLEAR OVERHEAD
7'0" Cab = 8'0" Clear Overhead
8'0" Cab = 9'0" Clear Overhead
*MORE SPACE IS DESIRABLE
LANDING LOCATION CHART
NOTE: Travel from landing to landing must be at least 20"TOTAL RAIL LENGTH ________RAIL BRACKET SPACING CHART (VERIFY ________)(VERIFY ________)(VERIFY ________)FRONTA
B CABOVERHEAD_______*SEE PAGE 6 FOR PIT DEPTH RECOMMENDATIONS*
BRKT
NO.
ELEV. FROM
PIT FLOOR
9 504"
8 444"
7 384"
6 324"
5 269"
4 204"
3 144"
2 84"
1 24"
LANDING FRONT REAR SIDE
2 X
1X
PEDESTAL
BRACKET
JACK
BRACKET
AB
12/21/2018
10" MIN. PIT DEPTH RECOMMENDED
(Absolute Min. 8")
12"12"
q- SEE PG 3
R1
R1
R4
R2
R3
Rail Forces
R1 197
R2 280
R3 4625
R4 616
SUPPORT WALL OF WOOD
OR FILLED CONCRETE BLOCK
(4 total) 1-3/4"x9-1/2" (2x10)
LAMINATED VENEER LUMBER (LVL)
HEIGHT OF HOISTWAY IS USED
TO ANCHOR RAIL BRACKETS
TOP VIEW OF RAILS 2X4 STUD FRAMING GLUED
AND SCREWED TO LVL's TO
HOLD IN PLACE
MUST BE GLUED
AND SCREWED
TOGETHER
FINISHED HOISTWAY
#4 REBAR 18" OC EACH WAY SINGLE MAT
FRONT
FINISHED DRYWALL FLUSH
TO ALL PIT WALLS
1/2" or 5/8" TYPE X DRYWALL
(Fire not required)
1/2" or 5/8" DRYWALL
#4 VERT. & LATERAL
18" OC EW
FINISHED SLAB
4"PIT FLOOR LOAD:
IMPACT--
4700# (950# CAPACITY)
STATIC--
2900# (950# CAPACITY)FINISHED HOISTWAYTOP VIEW OF PIT
2X4 TYPICAL
(VERIFY ________)
*SEE PAGE 3 FOR FINISHED
PIT DIMENSIONS*
*SEE PAGE 5 FOR THIS JOB*
RAIL BRACKET ENLARGED VIEW
SHOWING FASTENER HOLES
3116"
7716"
PIT REACTIONS
CAPACITY 950#
LOAD ON JACK 4,275 LBS.
LOAD ON BUFFERS 4,750 LBS.
q- SEE PG 3
PIT LAYOUT & 12" CL LVL BACKING
DRAWN BY:
TITLE:
DATE:CONTRACTOR NAME:
DRAWING #
APPROVED BY ELEVATOR DEALER:DATE:
Phone: (970) 242-2544
www.Rockymountainelevatorproducts.com
WLL 5/22/18
12/21/2018
DETAIL ASCALE 1 / 211223344AABBCCDDREVGLK-600000SCALEDWG NOSIZECGLASS EMI LAYOUT - SMARTLOCK GLTITLESHEET 1 OF 2 TOLERANCES ANGULAR: 1.XXX: ±.005 .XX: ±.015DRAWNMFGDO NOT SCALE DRAWINGAPPROVED4/8/2015WLLQACHECKEDANOTES: UNLESS OTHERWISE SPECIFIED.1. ALL GLASS (BY OTHERS) MUST BE LAMINATED (ASME A17.1 CODE 2.1.1.2.2(e)).2. ALL GLASS (BY OTHERS) MUST BE TEMPERED WITH A FINISHED THICKNESS OF 1/2".3. MUST BE BUILT IN ACCORDANCE TO ASME A17.1 CODE 5.3.1.1 AND CODE 5.3.1.7 (BY OTHERS).4. STRIKE WALL MUST HAVE MOUNTING POINTS WITHIN 2-4" OF THE LOCK CUTOUT.5. DOOR MUST HAVE A NON-GLASS EDGE GUARD. [ASME A17.1 CODE 2.11.7.2.4]6. DOOR/FRAME ASSY. MUST WITHSTAND 560 Lbs. OF FORCE OVER A 4" x 4" AREA WITHOUT CONSIDERABLE DEFLECTION [ASME A17.1 CODE 2.11.11.5.7]7. HINGES MUST NOT ALLOW THE DOOR TO PROTRUDE INTO THE HOISTWAY WHEN OPEN.8. HINGES MUST BE SELF CLOSING OR EQUIVALENT SYSTEM BY OTHERS.9. VERIFY MINIMUM STRIKE PANEL WIDTH WITH GLASS VENDOR.10. DOOR MUST BE A MINUMUM OF 3/8" ABOVE FINISHED FLOOR.11. PROVISIONS TO COVER OR HIDE THE LOCK WIRES ARE TO BE PERFORMED BY OTHERS.12. HANDLE HOLE SPACING 3.75" (96mm) CC.13. FINISH: BRUSHED STAINLESS STEELSTRIKE PANELDOORHINGE PANEL560 Lbs12/21/2018
DETAIL BSCALE 1 / 2DETAIL CSCALE 1 / 411223344AABBCCDDREVGLK-600000SCALEDWG NOSIZECGLASS EMI LAYOUT - SMARTLOCK GLTITLESHEET 2 OF 2 TOLERANCES ANGULAR: 1.XXX: ±.005 .XX: ±.015DRAWNMFGDO NOT SCALE DRAWINGAPPROVED4/8/2015WLLQACHECKEDBCBUILT-IN HALLCALL STATIONPULL HANDLE(EXTERIOR)LUNAR KEYACCESS PORT1.69.381.842.383.20.25 GAPS(TYP.).375MIN.2.00HOISTWAY SILLNOTES: UNLESS OTHERWISE SPECIFIED.1. SEE SHEET 1 FOR SPECIFICATIONS.2. HEIGHT DIMENSIONS ARE FROM FINISHED FLOOR.PULL HANDLE(INTERIOR)SILL LINEINTERIOR PULL HANDLE MUST NOTPROTRUDE PAST THE SILL LINE36.0031.321.37PRE WIRELOCATION40.31PRE WIRELOCATION.2511.75013.7503.0001.2506.8755.8752.251.000.250R.13(2) MAX4.004.00560 Lbs.750(2) .500(2) 12/21/2018
30" WIDE x
36" DEEP x 78" HIGH CLEAR SPACE IN FRONT OF CONTROLPANEL REQUIREDPHONE LINE
(By Others)
ELEVATOR
CONTROL
PANEL
AS TO ELEC.
SHOCK & FIRE
ANSI-ASME
A17.1 &
CAN-CSA
B44.1-ASME
A17.1
48°-135°
OPERATING
TEMPERATURE
CAR LIGHT DEDICATED
CIRCUIT, 120 VAC, 15
AMP, 1 PHASE, 60 HZ.
(By Others)
3 WIRE WITH
GROUND (L1, L2,
NEUTRAL, GROUND),
#10 GAGE WIRE,
230VAC, 30 AMP, 1
PHASE, 60HZ.
(By Others)
* CONTROL PANEL TO BE LOCATED
COMMON TO A SHAFT WALL. (ASK
ABOUT ADDITIONAL CHARGES TO
LOCATE THIS PANEL ELSEWHERE.)36" BOX HEIGHT4 3 4 " D E P T H W / D O O R
14-1
2"
BOX
WIDTH
CONTROL
PANEL
*LOCKABLE
DISCONNECTS/BREAKERS
ARE BUILT INTO THE
CONTROLLER RECESSED
UNDER FRONT CABINET
DOOR.
4' WHIPS
CAR LIGHT BREAKER
MOTOR/PUMP BREAKER
1.43810.20"10.00"
12.00"10.00"12.00"STANDARD FEATURES: SLOTTED SCREW CAM LATCH
CARBON STEEL
POWDER COAT WHITE FINISH
OPTIONS:
LOCK TYPE MATERIAL
CYLINDER LOCK AND KEY STAINLESS STEEL
ALLEN HEAD CAM LATCH #4 SATIN POLISH
SPANNER HEAD CAM LATCH
OTHER
MRL CONTROLLER
OPTIONAL MRL ACCESS PANEL
MACHINE ROOM LAYOUT - MRL
DRAWN BY:
TITLE:
DATE: CONTRACTOR NAME:
DRAWING #
APPROVED BY ELEVATOR DEALER: DATE:
Phone: (970) 242-2544
www.Rockymountainelevatorproducts.com
WLL 5/22/18
12/21/2018
WORK PERFORMED BY OTHERS
DELIVERY
1. Provide smooth (roll-able) access as closely as possible to the installation area.
HOISTWAY
1. Hoistway wall must be framed on each level from equipment shop drawings, not architectural drawings. (All dimensions are to finished
wall).
2. Hoistway must be plumb and square within 1/4".
3. Hoistway doors must be installed on all floors/landings as per shop drawings.
4. Hoistways must be COMPLETELY enclosed without grillwork or openings.
5. Drywall and taping must be complete by time of install.
6. No other pipes, wires, liquids, gasses, etc. are allowed in hoistway by code.
7. Hoistway temperature must be maintained within 60 to 100 degrees Farenheit.
8. All glass must be minimum of 14" laminated safety glass with visible markings of applicable code.
9. All exterior windows must have metal grillwork that will reject a 3" ball.
DOORS
1. Doors MUST comply with ASME A17.1 applicable code year (reference Mandatory Door Detail).
2. Doors accessing a garage landing must have a 1 hour fire rating.
3. The doors, hardware and closers (spring loaded hinges) are to be supplied and installed prior to installation.
4. Door openings must be laid out and framed per elevator shop drawings, not architectural drawings.
PIT
1. Pit must be poured to proper depth and size (reference shop drawings).
2. Pits deeper than 35" must will require a pit ladder or false floor built to listed pit depth dimension.
3. A dry, clean pit must be maintained.
MACHINE ROOM/EQUIPMENT CLOSET
1. Elevator/lift equipment may be placed in mechanical room with other equipment (water heater, furnace, etc.). If winding drum is not
in a dedicated room with self-closing, self-locking door, alternate protection is required for drive and cables.
2. Must be within 40' of hoistway. Some areas may not be allowed, please consult us before construction.
hoistway.
3. Must have a minimum of 3'0" clear area in front of controller as per electrical code.
4. Permanent telephone line to controller. Telephone line must be live before inspection. Cannot use V.O.I.P. phone system, cellular or
wireless systems. Phone must work in a power outage. (V.O.I.P. Requires signed liability waiver).
5. Machine room temperature must be maintained within 60-100 degrees Fahrenheit.
6. 230V Single Phase service whip needs to be ran to Controller. (See page 2 for breaker size).
7. 120V 15Amp Single Phase dedicated car light service whip needs to be ran to Controller.
CAB & FINISH
1. All cab choices and any materials being supplied for finishes of this elevator must be provided a minimum of 10 weeks prior to the
installation of elevator.
SAFETY
1. Hoistway doors must be installed and secured and/or OSHA approved removable barricades.
STORAGE
1. A dry, clean, and secure area needs to be provided for the elevator equipment not installed at time of delivey.
ACCEPTANCE/FINAL INSPECTION
1. The elevator phone with dial tone must be present prior to inspection.
2. Cab interior, door hardware, door trim, and door finishes must be complete prior to inspection.
3. The elevator cannot be turned over and/or used for construction until it has passed final inspection.
THIS PAGE ALONG WITH THE ATTACHED HOISTWAY, CAB, PIT AND DOOR DETAIL DRAWINGS MUST BE SIGNED AND RETURNED.
I HAVE READ AND UNDERSTAND ALL SITE REQUIREMENTS, INCLUDING THE HOISTWAY CONDITIONS FOR INSTALLATION.
Company:_____________________________ Job:___________________________________
Owner/Agent:______________________________ Date:___________________________
WORK PERFORMED BY OTHERS
DRAWN BY:
TITLE:
DATE: CONTRACTOR NAME:
DRAWING #
APPROVED BY ELEVATOR DEALER: DATE:
Phone: (970) 242-2544
www.rockymountainelevatorproducts.com
WLL 5/22/2018