HomeMy WebLinkAboutFile Documents.315 Dean St.0007.2018 (5).ACBKFixture Type:
Catalog Number:
Project:
Location:
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JUL 2017
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
AETHER - Open reflector
R3ARDT, R3ASDT
PRODUCT DESCRIPTION
Designed to fit in tight plenum space
FEATURES
• Designed to fit in tight plenum
• Wet location listed for trims
• 3.5” trim aperture, 3.5" housing height
• 35° cut-off angle
• Universal input voltage (120V-277V)
• *90 CRI with 3000K is Title 24 rated.
• 5 year WAC Lighting product warranty
TRIM (SEE NEXT PAGE FOR HOUSING)Beam Color Temp CRI Lumen CBCP Finish Interior/Trim
R3ARDT
Round
3d"
3a"
54"
N 25°
827
927
830
930*
835
840
2700K
2700K
3000K
3000K
3500K
4000K
85
90
85
90
85
85
1190
1000
1200
1005
1185
1335
4405
3910
4465
3600
4260
4775
HZWT
WT
BKWT
Haze/White
White
Black/White
F 40°
827
927
830
930*
835
840
2700K
2700K
3000K
3000K
3500K
4000K
85
90
85
90
85
85
1140
1025
1185
950
1175
1265
2360
2080
2465
1910
2345
2520
HZWT
WT
BKWT
Haze/White
White
Black/White
R3ASDT
Square
3w"
2d"
54"
N 25°
827
927
830
930*
835
840
2700K
2700K
3000K
3000K
3500K
4000K
85
90
85
90
85
85
1190
1000
1200
1005
1185
1335
4405
3910
4465
3600
4260
4775
HZWT
WT
BKWT
Haze/White
White
Black/White
F 40°
827
927
830
930*
835
840
2700K
2700K
3000K
3000K
3500K
4000K
85
90
85
90
85
85
1140
1025
1185
950
1175
1265
2360
2080
2465
1910
2345
2520
HZWT
WT
BKWT
Haze/White
White
Black/White
R3A__DT-_______-______
Example: R3ARDT-N930-HZWT
SPECIFICATIONS
Construction: Die-cast aluminum trim with extruded aluminum heat sink
Dimming: 100% - 0% with 0-10V dimmer (120V - 277V)
100% - 5% with Electronic Low Voltage (ELV) dimmer (120V only)
Input: 120V-277V AC
Power: 22.5W, power factor 0.98
Mounting: Retention clips firmly hold trim to housing.
Finish: Powder coated
Standards: ETL & cETL Listed, wet location listed trims
IC-rated airtight housing with available Chicago plenum version
Ceiling thickness: 2" - 12"
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JUL 2017
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
HOUSING Model
Shown with open square white trim
32"
4s"
4w"13d"
92" Min 142"
Max 212"
162"
HR-3LED-H17A New Construction
IC-rated, Airtight
HR-3LED-H17AC
New Construction
IC-rated, Airtight
Chicago Plenum
HR-3LED-H17____
Example: HR-3LED-H17A
AETHER -Housing
HR-3LED-H17A
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 1
INSTALLATION INSTRUCTION
Aether 3.5” Shallow Recessed Housing and Trims
HR-3LED-H17A
SAFETY INSTRUCTION
IMPORTANT: NEVER attempt any work without shutting off the electricity.
• Read all instructions before installing.
• System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations.
• Place the wall switch in the “OFF” position.
• Go to the main fuse box, or circuit breaker. Unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power
to the space that you are working on.
CAUTION:
All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or
broken. Failure to follow this instruction could invalidate the ETL/cETL listing of this fixture.
AVERTISSEMENT
IMPORTANT : COUPEZ L’ÉLECTRICITÉ AVANT TOUTE MANIPULATION.
• Lisez toutes les instructions avant d’installer.
• Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les règlements locaux.
• Placez l’interrupteur mural en position d’arrêt (« OFF »).
• Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »).
MISE EN GARDE
Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et
ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/cETL du luminaire.
OVERVIEW:
Housing is new construction IC, AIRTIGHT. Housing requires a trim for finished look. Check catalog for compatible trims choices
3"
4"
4"
13"
9" Min 14"
Max 21"
16"
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 2
INSTALLATION INSTRUCTION
Aether 3.5” Shallow Recessed Housing and Trims
HR-3LED-H17A
HOUSING INSTALLATION:
1. Install housing using two hanger bars provided, align the bottom
of the hanger bar with the bottom of the joist, secure the
“screw-nail” on each end by screw-driver or by hammer
(See FIG.1 detail A).
Slide fixture along hanger bar into desired location, use locking
screws to secure (See FIG.1 detail B).
For grid installation, hanger bars are supported on grids.
(See FIG.2)
2. To shorten hanger bars to fit in a 12” joist, snap off one section of
the hanger bars (See FIG.3).
3. Remove spring latched junction box cover and connect fixture
wires to building wires: insert each supply wire into appropriate
junction box connector. Connect black fixture wire to hot, white
fixture wire to neutral , green fixture wire to ground, grey fixture
wire to Dim (-) and purple fixture wire to Dim (+) (See FIG.4).
To utilize ELV, wire black (line hot) and white (line neutral) in
accordance to dimmer specifications. To utilize 0-10V dimming,
wire purple (dim+), gray (dim-), black (line hot), and white
(line neutral) in accordance to dimmer specifications.
When not using a dimmer, connect black fixture wire to hot, white
fixture wire to neutral and green fixture wire to ground. Leave all
other wires capped individually. Place all wiring and connectors
back in junction box and replace the junction box’s cover.
Place all wiring and connectors back in junction box and replace
the junction box’s cover.
FIG.1
FIG.2
FIG.3
FIG.4
A
A
B
B
Snap off one section fit in a 12” joist
Green: ground
Black: hot
White: neutral
Grey : 0 - 10V Dim (-)
Purple : 0-10V Dim (+)
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 3
DOWNLIGHT TRIM INSTALLATION
1. When installing in drywall, cut a hole 4 5/8” in the drywall.
Note: 1 1/2” inch maximum ceiling thickness.
2. Install light engine into the housing by rotating it clockwise
onto stud (Fig.5)
Connect light engine and housing power connectors (Fig.6).
3. Raise the trim to housing, depress trim spring clips and push
the trim assembly up until the trim ring is flush to the ceiling
(See FIG.7 and FIG.8).
INSTALLATION INSTRUCTION
Aether 3.5” Shallow Recessed Housing and Trims
HR-3LED-H17A
FIG.5
FIG.6
FIG.7
FIG.8
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 4
INSTALLATION INSTRUCTION
Aether 3.5” Shallow Recessed Housing and Trims
HR-3LED-H17A
DOWNLIGHT INVISIBLE TRIM INSTALLATION
1. When installing in drywall, cut a hole 4 5/8” in the drywall.
Note: 1 1/2” inch maximum ceiling thickness.
2. Raise the invisible trim frame aligning tab to slot in housing,
and put plaster shield inside (See FIG.9).
3. Secure the invisible trim frame to the housing, flush up
against the ceiling using the screws supplied (See FIG.10).
4. Apply plaster or spackle over Invisible frame and sand surface
when dry for a finished look (See FIG.11).
5. Remove the plaster cover when finishing is completed
(See FIG.12).
6. Install light engine into the housing by rotating it clockwise
onto stud (Fig.13)
Connect light engine and housing power connectors (Fig.14).
7. Raise the invisible trim assembly up to trim frame until the
trim ring is flush to the trim frame (See FIG.15).
FIG.9
FIG.10
FIG.11 FIG.12
FIG.15
Slot in housing
Tab
Plaster Shield
Remove plaster shield
FIG.13
FIG.14
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 5
INSTALLATION INSTRUCTION
Aether 3.5” Shallow Recessed Housing and Trims
HR-3LED-H17A
WALL WASH TRIM INSTALLATION
1. When installing in drywall, cut a hole 4 5/8” in the drywall.
Note: 1 1/2” inch maximum ceiling thickness.
2. Raise trim to ceiling, connect the power quick connector
secure safety cable to top of trim using screw provided
(as Fig.16).
3. Push the trim assembly up inside the housing until the trim
ring is flush to the ceiling (as Fig.17 and Fig.18).
FIG.16
FIG.17
FIG.18
Safety cable
Power
Quick
Connector
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 6
ADJUSTABLE TRIM INSTALLATION
1. When installing in drywall, cut a hole 4 5/8” in the drywall.
Note: 1 1/2” inch maximum ceiling thickness.
2. Loosen the locking tab by rotating counter clockwise (Fig.19)
Adjust to desire angle (From 0°to 30°), Retighten the locking
tab (Fig.20).
3. Raise trim to ceiling, connect the power quick connector.
Secure safety cable to top of trim using screw provided
(Fig.21).
4. Push the trim assembly up inside the housing until the trim
ring is flush to the ceiling (as Fig.22 and Fig.23).
INSTALLATION INSTRUCTION
Aether 3.5” Shallow Recessed Housing and Trims
HR-3LED-H17A
FIG.19
FIG.20
FIG.21
FIG.22
FIG.23
Loosen
Tighten
Locking Tab
Locking Tab
Safety cable
Power
Quick
Connector
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 7
LED AND DRIVER REPLACEMENT
1. Remove the trim or invisible trim
a. Remove the trim or invisible trim as shown below (FIG.24 & 25).
Remove the trim by pulling the trim’s edge
To remove invisible trim:
Remove the invisible trim by gently prying
between the invisible trim and lens
Trim Invisible Trim
INSTALLATION INSTRUCTION
Aether 3.5” Shallow Recessed Housing and Trims
HR-3LED-H17A
FIG.24 FIG.25
2. Replace Driver
a. Remove the LED module by rotating the LED module counterclockwise and pull out the LED module from housing (FIG.26),
then loosen wing nuts on the side of driver (FIG.27).
b. Tilt driver downward and remove from housing (FIG.28).
c. Remove screws to replace driver with new, rewire according to code and reinstall (FIG.29).
Wing Nuts
Screws
FIG.27
FIG.28 FIG.29
LED Module
Wire
connector
FIG.26
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 8
INSTALLATION INSTRUCTION
Aether 3.5” Shallow Recessed Housing and Trims
HR-3LED-H17A
FIG.29 FIG.30 FIG.31
Replace LED (Adjustable and Wall Wash Trim)
a. Remove the trim by pulling the trim’s edge (FIG.29)
b. Release the two screws from the light engine (FIG.30), remove the safety cable and use scissor to cut the LED input
c. Follow the steps (FIG.31) by removing #2, #3 then #4 screws from the light fixture. Replace the LED module.
3. Replace LED (Downlight Trim)
a. Disconnect wire connector, rotate the LED module counterclockwise and pull out to remove the LED module from housing (FIG.30).
b. Replace the LED by unscrewing the bracket, removing lens and reflector. Then, replace the LED (FIG.31 & 32).
LED Module
Insert black wire (-)
to round input
Insert red wire (+)
to square input
Wire
connector
Housing
LED
Reflector
Lens
Bracket
Screws
Connector
LED
FIG.30 FIG.31 FIG.32