Loading...
HomeMy WebLinkAboutFile Documents.315 Dean St.0007.2018 (5).ACBKFixture Type: Catalog Number: Project: Location: WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JUL 2017 waclighting.com Phone (800) 526.2588 Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050 Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122 Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760 AETHER - Open reflector R3ARDT, R3ASDT PRODUCT DESCRIPTION Designed to fit in tight plenum space FEATURES • Designed to fit in tight plenum • Wet location listed for trims • 3.5” trim aperture, 3.5" housing height • 35° cut-off angle • Universal input voltage (120V-277V) • *90 CRI with 3000K is Title 24 rated. • 5 year WAC Lighting product warranty TRIM (SEE NEXT PAGE FOR HOUSING)Beam Color Temp CRI Lumen CBCP Finish Interior/Trim R3ARDT Round 3d" 3a" 54" N 25° 827 927 830 930* 835 840 2700K 2700K 3000K 3000K 3500K 4000K 85 90 85 90 85 85 1190 1000 1200 1005 1185 1335 4405 3910 4465 3600 4260 4775 HZWT WT BKWT Haze/White White Black/White F 40° 827 927 830 930* 835 840 2700K 2700K 3000K 3000K 3500K 4000K 85 90 85 90 85 85 1140 1025 1185 950 1175 1265 2360 2080 2465 1910 2345 2520 HZWT WT BKWT Haze/White White Black/White R3ASDT Square 3w" 2d" 54" N 25° 827 927 830 930* 835 840 2700K 2700K 3000K 3000K 3500K 4000K 85 90 85 90 85 85 1190 1000 1200 1005 1185 1335 4405 3910 4465 3600 4260 4775 HZWT WT BKWT Haze/White White Black/White F 40° 827 927 830 930* 835 840 2700K 2700K 3000K 3000K 3500K 4000K 85 90 85 90 85 85 1140 1025 1185 950 1175 1265 2360 2080 2465 1910 2345 2520 HZWT WT BKWT Haze/White White Black/White R3A__DT-_______-______ Example: R3ARDT-N930-HZWT SPECIFICATIONS Construction: Die-cast aluminum trim with extruded aluminum heat sink Dimming: 100% - 0% with 0-10V dimmer (120V - 277V) 100% - 5% with Electronic Low Voltage (ELV) dimmer (120V only) Input: 120V-277V AC Power: 22.5W, power factor 0.98 Mounting: Retention clips firmly hold trim to housing. Finish: Powder coated Standards: ETL & cETL Listed, wet location listed trims IC-rated airtight housing with available Chicago plenum version Ceiling thickness: 2" - 12" WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JUL 2017 waclighting.com Phone (800) 526.2588 Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050 Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122 Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760 HOUSING Model Shown with open square white trim 32" 4s" 4w"13d" 92" Min 142" Max 212" 162" HR-3LED-H17A New Construction IC-rated, Airtight HR-3LED-H17AC New Construction IC-rated, Airtight Chicago Plenum HR-3LED-H17____ Example: HR-3LED-H17A AETHER -Housing HR-3LED-H17A WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 1 INSTALLATION INSTRUCTION Aether 3.5” Shallow Recessed Housing and Trims HR-3LED-H17A SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. • Read all instructions before installing. • System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations. • Place the wall switch in the “OFF” position. • Go to the main fuse box, or circuit breaker. Unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the space that you are working on. CAUTION: All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/cETL listing of this fixture. AVERTISSEMENT IMPORTANT : COUPEZ L’ÉLECTRICITÉ AVANT TOUTE MANIPULATION. • Lisez toutes les instructions avant d’installer. • Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les règlements locaux. • Placez l’interrupteur mural en position d’arrêt (« OFF »). • Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). MISE EN GARDE Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/cETL du luminaire. OVERVIEW: Housing is new construction IC, AIRTIGHT. Housing requires a trim for finished look. Check catalog for compatible trims choices 3" 4" 4" 13" 9" Min 14" Max 21" 16" WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 2 INSTALLATION INSTRUCTION Aether 3.5” Shallow Recessed Housing and Trims HR-3LED-H17A HOUSING INSTALLATION: 1. Install housing using two hanger bars provided, align the bottom of the hanger bar with the bottom of the joist, secure the “screw-nail” on each end by screw-driver or by hammer (See FIG.1 detail A). Slide fixture along hanger bar into desired location, use locking screws to secure (See FIG.1 detail B). For grid installation, hanger bars are supported on grids. (See FIG.2) 2. To shorten hanger bars to fit in a 12” joist, snap off one section of the hanger bars (See FIG.3). 3. Remove spring latched junction box cover and connect fixture wires to building wires: insert each supply wire into appropriate junction box connector. Connect black fixture wire to hot, white fixture wire to neutral , green fixture wire to ground, grey fixture wire to Dim (-) and purple fixture wire to Dim (+) (See FIG.4). To utilize ELV, wire black (line hot) and white (line neutral) in accordance to dimmer specifications. To utilize 0-10V dimming, wire purple (dim+), gray (dim-), black (line hot), and white (line neutral) in accordance to dimmer specifications. When not using a dimmer, connect black fixture wire to hot, white fixture wire to neutral and green fixture wire to ground. Leave all other wires capped individually. Place all wiring and connectors back in junction box and replace the junction box’s cover. Place all wiring and connectors back in junction box and replace the junction box’s cover. FIG.1 FIG.2 FIG.3 FIG.4 A A B B Snap off one section fit in a 12” joist Green: ground Black: hot White: neutral Grey : 0 - 10V Dim (-) Purple : 0-10V Dim (+) WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 3 DOWNLIGHT TRIM INSTALLATION 1. When installing in drywall, cut a hole 4 5/8” in the drywall. Note: 1 1/2” inch maximum ceiling thickness. 2. Install light engine into the housing by rotating it clockwise onto stud (Fig.5) Connect light engine and housing power connectors (Fig.6). 3. Raise the trim to housing, depress trim spring clips and push the trim assembly up until the trim ring is flush to the ceiling (See FIG.7 and FIG.8). INSTALLATION INSTRUCTION Aether 3.5” Shallow Recessed Housing and Trims HR-3LED-H17A FIG.5 FIG.6 FIG.7 FIG.8 WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 4 INSTALLATION INSTRUCTION Aether 3.5” Shallow Recessed Housing and Trims HR-3LED-H17A DOWNLIGHT INVISIBLE TRIM INSTALLATION 1. When installing in drywall, cut a hole 4 5/8” in the drywall. Note: 1 1/2” inch maximum ceiling thickness. 2. Raise the invisible trim frame aligning tab to slot in housing, and put plaster shield inside (See FIG.9). 3. Secure the invisible trim frame to the housing, flush up against the ceiling using the screws supplied (See FIG.10). 4. Apply plaster or spackle over Invisible frame and sand surface when dry for a finished look (See FIG.11). 5. Remove the plaster cover when finishing is completed (See FIG.12). 6. Install light engine into the housing by rotating it clockwise onto stud (Fig.13) Connect light engine and housing power connectors (Fig.14). 7. Raise the invisible trim assembly up to trim frame until the trim ring is flush to the trim frame (See FIG.15). FIG.9 FIG.10 FIG.11 FIG.12 FIG.15 Slot in housing Tab Plaster Shield Remove plaster shield FIG.13 FIG.14 WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 5 INSTALLATION INSTRUCTION Aether 3.5” Shallow Recessed Housing and Trims HR-3LED-H17A WALL WASH TRIM INSTALLATION 1. When installing in drywall, cut a hole 4 5/8” in the drywall. Note: 1 1/2” inch maximum ceiling thickness. 2. Raise trim to ceiling, connect the power quick connector secure safety cable to top of trim using screw provided (as Fig.16). 3. Push the trim assembly up inside the housing until the trim ring is flush to the ceiling (as Fig.17 and Fig.18). FIG.16 FIG.17 FIG.18 Safety cable Power Quick Connector WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 6 ADJUSTABLE TRIM INSTALLATION 1. When installing in drywall, cut a hole 4 5/8” in the drywall. Note: 1 1/2” inch maximum ceiling thickness. 2. Loosen the locking tab by rotating counter clockwise (Fig.19) Adjust to desire angle (From 0°to 30°), Retighten the locking tab (Fig.20). 3. Raise trim to ceiling, connect the power quick connector. Secure safety cable to top of trim using screw provided (Fig.21). 4. Push the trim assembly up inside the housing until the trim ring is flush to the ceiling (as Fig.22 and Fig.23). INSTALLATION INSTRUCTION Aether 3.5” Shallow Recessed Housing and Trims HR-3LED-H17A FIG.19 FIG.20 FIG.21 FIG.22 FIG.23 Loosen Tighten Locking Tab Locking Tab Safety cable Power Quick Connector WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 7 LED AND DRIVER REPLACEMENT 1. Remove the trim or invisible trim a. Remove the trim or invisible trim as shown below (FIG.24 & 25). Remove the trim by pulling the trim’s edge To remove invisible trim: Remove the invisible trim by gently prying between the invisible trim and lens Trim Invisible Trim INSTALLATION INSTRUCTION Aether 3.5” Shallow Recessed Housing and Trims HR-3LED-H17A FIG.24 FIG.25 2. Replace Driver a. Remove the LED module by rotating the LED module counterclockwise and pull out the LED module from housing (FIG.26), then loosen wing nuts on the side of driver (FIG.27). b. Tilt driver downward and remove from housing (FIG.28). c. Remove screws to replace driver with new, rewire according to code and reinstall (FIG.29). Wing Nuts Screws FIG.27 FIG.28 FIG.29 LED Module Wire connector FIG.26 WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Ave • Ontario, CA 91761 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JULY, 2016 8 INSTALLATION INSTRUCTION Aether 3.5” Shallow Recessed Housing and Trims HR-3LED-H17A FIG.29 FIG.30 FIG.31 Replace LED (Adjustable and Wall Wash Trim) a. Remove the trim by pulling the trim’s edge (FIG.29) b. Release the two screws from the light engine (FIG.30), remove the safety cable and use scissor to cut the LED input c. Follow the steps (FIG.31) by removing #2, #3 then #4 screws from the light fixture. Replace the LED module.      3. Replace LED (Downlight Trim) a. Disconnect wire connector, rotate the LED module counterclockwise and pull out to remove the LED module from housing (FIG.30). b. Replace the LED by unscrewing the bracket, removing lens and reflector. Then, replace the LED (FIG.31 & 32). LED Module Insert black wire (-) to round input Insert red wire (+) to square input Wire connector Housing LED Reflector Lens Bracket Screws Connector LED FIG.30 FIG.31 FIG.32