HomeMy WebLinkAboutFile Documents.320 W Bleeker St.0188.2017.ARBKDEW POINT CALCULATION JOB NAME: 320 Bleeker JOB NUMBER: 17024.00 DATE: 7/17/17 CALCS BY: JCB DP @ DP @ DP @ DP @ DP @ 20% RH 25% RH 30% RH 35% RH 45% RH 30 33 37 41 48 -20 Indoor design temperature (IDT)70 90 R-value 0.17 0.00 0.00 0.94 38.00 0.00 11.00 0.56 0.61 51.28 12.17 49 41 YES Note: To minimize the potential for condensation problems, humidity levels within the home must be properly controlled and adjusted based on outdoor temperatures. Is TA warmer than the DPA? Inside air layer R-Total R-value at A A: point of condensation analysis Vapor barrier 5/8" gypboard TA = IDT - (R-value at A)/(R-Total) * (Delta T) TA = Temperature at point A DPA = Dew point at point A (35% RH) R-11 Batt Insulation Roof Underlayment 3/4" Plywood R-38 Spray Foam Insualtion Outdoor design temperature (ODT) Delta T = IDT - ODT Layer Thermal Resistance of Proposed Roof Assembly Outside air layer Roofing 7/17/17 City of Aspen Received 8/15/17 Building Department 0188.2017.ARBK