Loading...
HomeMy WebLinkAboutFile Documents.320 W Bleeker St.0188.2017 (48).ARBKPHASE CON ENVIRONMENTAL CONSULTANTS Final Clearance Air Monitoring Services Date: April 5, 2018 Project: Abatement of ACM texture and sheet vinyl flooring prior to building demolition at 320 W. Bleeker Street, Aspen, Colorado 81611. Contractor: Quetzal Environmental, Aurora, Colorado Air Monitoring Description: Phase Con provided final clearance air monitoring services at the project site listed above on April 5, 2018. Air samples were situated inside the enclosure so as to be representative of the entire work space. Air samples were obtained utilized aggressive sampling methods to aid in ensuring that any fibrous material left in the enclosure would be entrained in the air during the sampling period. Abatement Description: Abatement of ACM texture and sheet vinyl flooring prior to building demolition.Q Comments and Recommendations: PCM analysis of the final clearance air samples revealed airborne fiber levels inside the containment area(s) to be less than the Colorado State Maximum Allowable Asbestos Level (MAAL) and the EPA clearance level of 0.010 fibers per cubic centimeter of air; therefore, the area(s) may be re -occupied under non -abatement conditions. 31as A. Close rado State Air Monitoring Specialist #2930 166 Peregrine rM&uri C,rand;C'd(Drr, t:t u1 tJ ('Iffice:9 )_�60-3341 pceconsultants,aq\,t testoffice.net PHASE CON ENVIRONMENTAL CONSULTANTS PCM LABORATORY ANALYSIS OSHA Reference Method - NIOSH 7400 Client: Quetzal Environmental Sampling Date: 4/05/18 Aurora, Colorado Technician/Analyst: D. Close Project: 320 W. Bleeker Street CDPHE Technician ID: 2930 Aspen, Colorado Abatement Contractor: Quetzal Environmental, Aurora, Colorado Description of Work: Abatement of ACM texture and sheet vinyl flooring prior To building demolition. SAMPLE SAMPLE DESCRIPTION AIR VOLUME fibers/fields ID f/cc 01 Final Clearance Sample - 595 L 4.5/100 Texture/Sheet Vinyl Enclosure <0.006 f/cc 02 Final Clearance Sample - 595 L 4.5/100 Texture/Sheet Vinyl Enclosure <0.006 F/CC 03 Final Clearance Sample - 595 L 5.0/100 Texture/Sheet Vinyl Enclosure <0.006 F/CC 04 Final Clearance Sample - 595 L 4.0/100 Texture/Sheet Vinyl Enclosure <0.006 F/CC 05 Final Clearance Sample - 595 L 4.5/100 Texture/Sheet Vinyl Enclosure <0.006 F/CC 06 Blank ----- NONE DETECTED P7--T Blank ----- NONE DETECTED * Colorado State Clearance Level is 0.010 f/cc of air Technician/Analyst: 21 F6 Peregrine r o!art Grand jul)ction, CO 81507 ,'office: 970-260-3341 1pceconsultant:,;a)qwestoif ce.net Certificates f 0 ,1 1876' Colorado Department of Public Health and Environment ASBESTOS CERTIFICATION* This certifies that Douglas A. Close Certification No.: 2930 has met the requirements ements of '? 5-7-507, C.K.S. and Air Quality Control rt B, and is hereby certified by the Commission Regulation No. 8, Pa state of Colorado in the following discipline: Air Monitoring Specialist* Issued: November 01, 2011, Expires: December 08, 2018 This cerli%icale is valid oniti• will' tlu' possession 4 11 current Division -approved certi/iculion in the discipline specifier) above. Autt orized APCD Representative SEAL