HomeMy WebLinkAboutFile Documents.320 W Bleeker St.0188.2017 (51).ARBKWest Slope Testing & Inspection LLC Report #1 3177 Glendam Dr. Grand Junction, CO 81504 Page 1 of 1 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Date: 9-26-18 Project: 320 West Bleeker LLC Address: 320 W. Bleeker St. Aspen, CO Building Permit No: 0 1 88.2017.ARBk General Contractor: Rutgers Construction Contractor that Performed Work: Sopris Steel Inspection of shop fabrication or field work at job site: Field Report: Inspected high strength A325 bolting at steel beam & column connections main level framing. Also verified epoxy anchor bolt installation at column bases foundation level & at steel beam pockets main level framing. The bolting inspected above appeared to be in substantial conformance with the plans, and the requirements of the AISC/RCSC Specification for high strength bolting. Further inspections should be performed on any remaining welding and/or bolting. Inspector/Technician: Douglas E Young Douglas E. Young Ce' Iicatio #510227A ctu t Welc ing S r asp or c St Bo ting l Inspector Spray -applied Fireproofi Special inspector