HomeMy WebLinkAboutFile Documents.320 W Bleeker St.0188.2017 (51).ARBKWest Slope Testing & Inspection LLC Report #1
3177 Glendam Dr.
Grand Junction, CO 81504 Page 1 of 1
Phone: 970-434-6988
Cell: 970-260-2844
Inspection Report
Date: 9-26-18
Project: 320 West Bleeker LLC
Address: 320 W. Bleeker St. Aspen, CO
Building Permit No: 0 1 88.2017.ARBk
General Contractor: Rutgers Construction
Contractor that Performed Work: Sopris Steel
Inspection of shop fabrication or field work at job site: Field
Report: Inspected high strength A325 bolting at steel beam & column
connections main level framing. Also verified epoxy anchor bolt installation at
column bases foundation level & at steel beam pockets main level framing.
The bolting inspected above appeared to be in substantial conformance with the
plans, and the requirements of the AISC/RCSC Specification for high strength
bolting.
Further inspections should be performed on any remaining welding and/or
bolting.
Inspector/Technician: Douglas E Young
Douglas E. Young
Ce' Iicatio #510227A
ctu t Welc ing S r asp or
c St Bo ting l Inspector
Spray -applied Fireproofi Special inspector