Loading...
HomeMy WebLinkAboutFile Documents.323 W Hallam St.0015.2019 (7).ARBKSPECIFICATION FEATURES Lower Shielding Reflector Painted die cast aluminum or spun aluminum lower reflector with a lensed upper optical chamber providing superior lumen output with minimal source brightness. Spun reflectors are offered in all Portfolio Alzak® finishes. Available with non-conductive polymer trim. Reflector is retained with two torsion springs holding the flange tight to the finished ceiling surface. Plaster Frame / Collar Galvanized steel ring installs with 2 mouse trap springs for secure installation and accommodates up to 2 inch ceiling thickness. Retrofit - Converts existing HID, incandescent or compact fluorescent downlights to energy saving LED. Simple below ceiling installation without removing the existing fixture. Pre-wired flexible conduit with snap in connector installs into 1/2” knockout on the existing junction box. Thermal Aluminum heat sink conducts heat away from the LED module for optimal performance and long life. LED Chip on board with a multitude of highly efficient white LED’s, combined with a high reflectance upper reflector and convex transitional lens produce even distribution with no pixilation. Rated for 50,000 hours at 70% lumen maintenance. Auto resetting, thermally protected, LED’s are turned off when safe operating temperatures are exceeded. Color variation within 3-step MacAdam ellipses. Quick disconnect allows for tool-less replacement of LED engine from below ceiling. Available in 80, 90 or 97 CRI. D2W™ – dim-to-warm shifts CCT from 3000K to1850K as fixture dims mimicking halogen sources. W2N - Tunable white CCT range 2700K to 6500K or 2000K to 5000K, 90 CRI. Driver Standard 120-277V 0-10V dimming driver provides flicker free dimming from 100% to 1%. Optional 120V leading edge, <1% 0-10V, Fifth Light, DMX or Lutron® Ecosystem. Driver can be serviced from above or through the aperture. Connected Lighting Systems WaveLinx tilemount daylight sensor includes control module, sensor and cable allowing use with the comprehensive lighting system. LumaWatt Pro (powered by Enlighted) wireless tile mount sensor and relay accessory enables wireless control using a tile mount sensor accessory. Code Compliance Thermally protected and cULus listed for wet locations with covered ceiling. IP66 rated when used with IP66 gasket kit accessory. Optional City of Chicago environmental air (CCEA) marking for plenum applications. EMI/RFI emissions per FCC 47CFR Part 18 Class B consumer limits. 2000 lumens and above are Non-IC rated - Insulation must be kept 3” from top and sides of housing. IC rated up to 1500 lumens. 5000 lumen and above are marked spacing and must follow spacing requirements. RoHS Compliant. Photometric testing completed in accordance with IES LM 79 and TM-30 standards. LED life testing completed in accordance with LM 80 standards. Warranty 5-year warranty LDRT4B EU4B 4LBW 4LBM 4LBN 1000-6000 Lumen LED STEPREPEAT> Narrow, Medium, or Wide Beam International, Remodel, Retrofit 4-inch recessed LED for international, remodel or retrofit applications. Offered with narrow, medium, or wide beam reflectors designed for glare free even illumination. Featuring a two-stage diffused reflector system producing smooth distribution with excellent light control and low aperture brightness. Lumen packages range from 1000 to 6000 with color temperatures of 2400K, 2700K, 3000K, 3500K, 4000K, and 5000K. VividTune: Dim-to-warm technology – similar to halogen at full power, the 3000K LED warms smoothly as dimmed to 1850K creating a rich warm glow within the space. Tunable white technology - adjust the color temperature from warm white to cool white while independently controlling intensity. DESCRIPTION Refer to ENERGY STAR® Qualified Products List. Can be used to comply with California Title 24 High Efficacy requirements. Certified to California Title 20 Appliance Efficiency Database. 4-3/4" MIN[122mm MIN]5-3/16" MAX[132mm MAX] 5-11/16"[144mm] 9-7/8"[251mm] MAX HEIGHT(SEE TABLE)1/2" MIN[13mm MIN] 2" MAX[51mm MAX] 1000-2000 LUMENS 3000-5000 LUMENS 6000 LUMENS NARROW / MEDIUM 5-1/4" [133mm]5-1/4" [133mm]7" [178mm] WIDE / WALL WASH 4-3/4" [121mm]4-3/4" [121mm]6-1/2" [165mm] SHALLOW 3-1/2" [89mm]3-1/2" [89mm]NA 12-7/8"[328mm]20-3/16"[514mm] 5-1/2"[132mm] 3-9/16"[93mm] 2-1/16"[54mm]2-3/4"[70mm] 7-1/16"[180mm] 6-7/8"[176mm] 5-7/8"[149mm] TD520036EN October 5, 2018 8:44 AM Portfolio Catalog #Type Project Comments Date Prepared by LDRT4B-15-D010 323 W. HALLAM ST. 15_323WHALLAM_SPEC SHEET_LED RECESSED LIGHT 01/24/2019 LDRT4B EU4B 4LBW 4LBM 4LBN ORDERING INFORMATION ENERGY DATA Sound Rating: Class A standards (Values at non-dimming line voltage) Minimum Starting Temperature: -30°C (-22°F) EMI/RFI: FCC Title 47 CFR, Part 15, Class B (Consumer) Input Voltage: UNV (120V - 277V) Power Factor: >0.90 (at nominal input 120-277 VAC & 100% of Rated Output Power) Input Frequency: 50/60Hz 1000 Lumen D010 1500 Lumen D010 Input Power: 11W THD: <14%Input Power: 15.5W THD: <13% 120V Input Current: 0.09A 277V Input Current: 0.04A 120V Input Current: 0.13A 277V Input Current: 0.06A 2000 Lumen D010 3000 Lumen D010 Input Power: 21.2W THD: <9%Input Power: 27.6W THD: <10% 120V Input Current: 0.18A 277V Input Current: 0.08A 120V Input Current: 0.23A 277V Input Current: 0.10A 4000 Lumen D010 Input Power: 41.6W THD: <13% 120V Input Current: 0.35A 277V Input Current: 0.15A 120V 277V Lumens Inrush (A)Duration (ms)Inrush (A)Duration (ms) 1000 Lumen D010 1.02 0.041 2.18 0.021 1500 Lumen D010 1.02 0.042 2.24 0.064 2000 Lumen D010 1.02 0.077 2.43 0.027 3000 Lumen D010 1.15 0.067 3.26 0.027 4000 Lumen D010 1.2 0.088 3.9 0.03 ENERGY SAMPLE NUMBER: LDRT4B15D010EMBOD Housing Lumens1 Voltage Driver Options3 LDRT4B=LED Downlight Retrofit 4” Nominal Aperture LDRT4BCP=LED Downlight Retrofit 4” Nominal Aperture, Chicago Plenum 10=1000 lumens 15=1500 lumens 20=2000 lumens 30=3000 lumens 40=4000 lumens 50=5000 lumens16 60=6000 lumens16 Blank=120-277V 3=347V (step down transformer) 1000 - 4000 Lumen D010=0-10V Dimming, 1% to 100%, 120V-277V D010TR=0-10V or Line Voltage Dimming, 5% to 100%, 120V-277V DE010=0-10V Dimming, 0% to 100%, 120V-277V D5LT=Fifth Light® (DALI) Dimming, 0% to 100%, 120V-277V DMX=DMXRDM Dimming, 0% to 100%, 120V-277V14 DL2=Lutron® Hi-Lume Forward Phase Dimming, 1% to 100%, 120V Only DL3=Lutron® Hi-Lume 3 Wire Dimming, 1% to 100%, 120V-277V DLE=Lutron Ecosystem dimming 1% to 100%, 120V-277V 5000-6000 D010TE=0-10V 1% or trailing edge 10%, 120-277V (120V only with trailing edge dimming) Tunable white 1000-2000 Lumens18 1DE010W2N2050=0-10V dimming, 0% to 100%, 120V, 2000K - 6500K 1DE010W2N2765=0-10V dimming, 0% to 100%, 120V, 2700K - 5000K 1D5LTW2N2050=Fifth Light (DALI), 0% to 100%, 120, 2000K - 6500K 1D5LTW2N2765=Fifth Light (DALI), 0% to 100%, 120V, 2700K - 5000K 2DE010W2N2050=0-10V dimming, 0% to 100%, 277V, 2000K - 6500K 2DE010W2N2765=0-10V dimming, 0% to 100%, 277V, 2700K - 5000K 2D5LTW2N2050=Fifth Light (DALI), 0% to 100%, 277V, 2000K - 6500K 2D5LTW2N2765=Fifth Light (DALI), 0% to 100%, 277V, 2700K - 5000K EMBOD=Bodine® Emergency Module with Remote Test Switch3 EM7=7W Emergency Module with Remote Test Switch3, 10 EM14=14W Emergency Module with Remote Test Switch3, 10 SWPD1=Factory installed WaveLinx tilemount daylight sensor (includes control module, sensor, cable, and tile mount)3, 15 LWTPD1=Factory installed LumaWatt Pro wireless sensor kit3, 15 SAMPLE NUMBER: EU4B10208035 Power Module Lumen Levels1 CRI Color EU4B=4” Universal LED Module 1020=1000, 1500, 2000 lumens 3040=3000-4000 lumens14 5000=5000 lumens16 6000=6000 lumens16 1015IC=1000, 1500 lumen IC rated 80=80 CRI Minimum 90=90 CRI Minimum 97=97 CRI Minimum 80 CRI 27=2700K 30=3000K 35=3500K 40=4000K 50=5000K 90 CRI 24=2400K 27=2700K 30=3000K 35=3500K 40=4000K 50=5000K 97 CRI 27=2700K 30=3000K Dim 2 Warm 109030D2W=1000 lumen, 90 CRI, Dim 2 Warm, IC rated 159030D2W=1500 lumen, 90 CRI, Dim 2 Warm, IC rated 209030D2W=2000 lumen, 90 CRI, Dim 2 Warm 309030D2W=3000 lumen, 90 CRI, Dim 2 Warm Tunable white18 1020W2N902050 =1000, 1500, 2000 lumens, 90 CRI, tunable white 2000K-5000K 1020W2N902765 =1000, 1500, 2000 lumens, 90 CRI, tunable white 2700K-6500K SAMPLE NUMBER: 4LBM1LI Trim Distribution4 Flange Finish 4LB=4” LED N=Narrow (25° Beam), Spun Aluminum M=Medium (50° Beam), Spun Aluminum W=Wide (75° Beam), Spun Aluminum S=Shallow (75° Beam), Spun Aluminum 17 PS=Non-conductive Shallow (75° Beam), Injection Molded white11, 12 CS=Cast Shallow (75° Beam), Die Cast Aluminum12 BA=Baffle, Spun Aluminum5 0=White Polymer Trim Ring 1=Self-flanged13 2=White Painted Self-flanged LI=Specular Clear7 H=Semi-Specular Clear7 WMH=Warm Haze7 WH=Wheat7 GPH=Graphite Haze7 B=Specular Black7 MW=Matte White MB=Matte Black8 MMS=Matte Metallic Silver9 Accessories TRM4=Metal Trim Ring, Specify Color2 TRR4=Rimless Trim Ring2 LGSKT4IP66=IP66 Gasket Kit Connected Lighting Systems PORLWTPD1=LumaWatt Pro wireless sensor kit (0-10V only) field installed15 TMSWPD1=WaveLinx tilemount daylight sensor (includes control module, sensor, cable and tile mount field installed15 Notes: 1 Nominal Lumens will vary depending on selected color, driver and reflector finish. 2 Order trim with polymer trim ring (Consult specification sheet for color ordering information and options). 3 Not available with Chicago Plenum. 4 Beam angles are nominal with LI finish trims. 5 Only available with Matte White and Matte Black Finishes. 6 Available only on PS, CS, and BA distributions. 7 Not available on PS, CS or BA distributions. 8 Available on CS and BA distributions 9 Available on CS distributions 10 ULus listed only 11 PS available in self flange matte white only 12 Offered up to 2000 lumens 13 Flange is the same finish as the reflector. 14 DMX fixtures default to full on upon loss of DMX signal. 15 Refer to system specifications for additional information, features, and benefits. Order either factory installed option or accessory. Use with 0-10V driver. 16 Product is marked spacing and must be installed with the following minimum spacing - Center to center of adjacent luminaires: 36” - Center of luminaire to side of building member: 18” - Minimum overhead: ½” 17 Offered up to 4000 lumens 18 Non-IC 01/24/2019 Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting CANDLEPOWER DISTRIBUTION Downlight 697 1395 2092 2790 15º30º 45º 60º 75º 90º CANDLEPOWER DISTRIBUTION Downlight 567 1134 1706 2267 15º30º 45º 60º 75º 90º CANDLEPOWER DISTRIBUTION Downlight 254 508 762 1016 15º30º 45º 60º 75º 90º CANDLEPOWER DISTRIBUTION Downlight 172 344 516 688 15º30º 45º 60º 75º 90º ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 1144 77.3 0-40 1406 95 0-60 1477 99.7 0-90 1481 100 90-180 0 0 0-180 1481 100 ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 926 82.1 0-40 1094 97 0-60 1127 99.9 0-90 1128 100 90-180 0 0 0-180 1128 100 ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 512 34.2 0-40 816 54.5 0-60 1333 89 0-90 1497 100 90-180 0 0 0-180 1497 100 ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 816 53.8 0-40 1252 82.5 0-60 1513 99.7 0-90 1518 100 90-180 0 0 0-180 1518 100 MEDIUM (50° BEAM) Test Number P201206 Housing LD4B15D010 Module EU4B10208035 Trim 4LBM1LI Lumens 1481 Efficacy 103.6 Lm/W SC 0.71 NARROW (25° BEAM) Test Number P201208 Housing LD4B15D010 Module EU4B10208035 Trim 4LBN1LI Lumens 1128 Efficacy 78.9 Lm/W SC 0.5 SHALLOW (75° BEAM) Test Number P201210 Housing LD4B15D010 Module EU4B10208035 Trim 4LBCS1MMS Lumens 1497 Efficacy 104.7 Lm/W SC 1.16 WIDE (75° BEAM) Test Number P201204 Housing LD4B15D010 Module EU4B10208035 Trim 4LBW1LI Lumens 1518 Efficacy 106.2 Lm/W SC 1.3 CONE OF LIGHT D FC L W 5.5'74.9 3.8 3.8 7'46.3 5 5 8'35.4 5.6 5.6 9'28 6.4 6.4 10'22.7 7 7 12'15.7 8.4 8.4 0ºD CONE OF LIGHT D FC L W 5.5'92.2 2.6 2.6 7'56.9 3.4 3.4 8'43.6 3.8 3.8 9'34.4 4.4 4.4 10'27.9 4.8 4.8 12'19.4 5.8 5.8 0ºD CONE OF LIGHT D FC L W 5.5'22.7 6.2 6.2 7'14 8 8 8'10.7 9.2 9.2 9'8.5 10.4 10.4 10'6.9 11.6 11.6 12'4.8 13.8 13.8 0ºD CONE OF LIGHT D FC L W 5.5'30.2 7 7 7'18.7 9 9 8'14.3 10.4 10.4 9'11.3 11.6 11.6 10'9.1 13 13 12'6.4 15.6 15.6 0ºD CANDELA TABLE Degrees Vertical Candela 0 2267 5 2227 15 1690 25 1027 35 409 45 70 55 8 65 3 75 1 85 0 90 0 CANDELA TABLE Degrees Vertical Candela 0 2790 5 2550 15 1421 25 667 35 266 45 32 55 3 65 1 75 0 85 0 90 0 CANDELA TABLE Degrees Vertical Candela 0 688 5 682 15 645 25 577 35 486 45 380 55 253 65 126 75 32 85 1 90 0 CANDELA TABLE Degrees Vertical Candela 0 914 5 925 15 998 25 977 35 707 45 286 55 30 65 4 75 1 85 0 90 0 LUMINANCE Average Candela Degrees Average 0° Luminance 45 1072 55 151 65 77 75 42 85 0 LUMINANCE Average Candela Degrees Average 0° Luminance 45 489 55 55 65 26 75 0 85 0 LUMINANCE Average Candela Degrees Average 0° Luminance 45 5827 55 4771 65 3226 75 1339 85 124 LUMINANCE Average Candela Degrees Average 0° Luminance 45 4372 55 574 65 100 75 42 85 0 PHOTOMETRY LDRT4B EU4B 4LBW 4LBM 4LBN 01/24/2019 Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting CANDLEPOWER DISTRIBUTION Downlight 1906 3813 5719 7625 15º30º 45º 60º 75º 90º CANDLEPOWER DISTRIBUTION Downlight 1504 3007 4511 6015 15º30º 45º 60º 75º 90º CANDLEPOWER DISTRIBUTION Downlight 694 1388 2081 2775 15º30º 45º 60º 75º 90º CANDLEPOWER DISTRIBUTION Downlight 470 940 1410 1880 15º30º 45º 60º 75º 90º ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 3036 77.3 0-40 3731 95 0-60 3918 99.7 0-90 3929 100 90-180 0 0 0-180 3929 100 ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 2531 82.1 0-40 2989 97 0-60 3080 99.9 0-90 3083 100 90-180 0 0 0-180 3083 100 ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 1400 34.2 0-40 2230 54.5 0-60 3645 89 0-90 4093 100 90-180 0 0 0-180 4093 100 ZONAL LUMEN SUMMARY Zone Lumens % Fixture 0-30 2230 53.8 0-40 3421 82.5 0-60 4134 99.7 0-90 4148 100 90-180 0 0 0-180 4148 100 MEDIUM (50° BEAM) Test Number P201207 Housing LD4B40D010 Module EU4B30408035 Trim 4LBM1LI Lumens 3929 Efficacy 94 Lm/W SC 0.71 NARROW (25° BEAM) Test Number PP201209 Housing LD4B40D010 Module EU4B30408035 Trim 4LBN1LI Lumens 3083 Efficacy 73.8 Lm/W SC 0.5 SHALLOW (75° BEAM) Test Number P201211 Housing LD4B40D010 Module EU4B30508035 Trim 4LBCS1MMS Lumens 4093 Efficacy 97.9 Lm/W SC 1.16 WIDE (75° BEAM) Test Number P201205 Housing LD4B40D010 Module EU4B30408035 Trim 4LBW1LI Lumens 4148 Efficacy 99.2 Lm/W SC 1.3 CONE OF LIGHT D FC L W 5.5'198.8 3.8 3.8 7'122.7 5 5 8'94 5.6 5.6 9'74.3 6.4 6.4 10'60.1 7 7 12'41.8 8.4 8.4 0ºD CONE OF LIGHT D FC L W 5.5'252.1 2.6 2.6 7'155.6 3.4 3.4 8'119.1 3.8 3.8 9'94.1 4.4 4.4 10'76.2 4.8 4.8 12'53 5.8 5.8 0ºD CONE OF LIGHT D FC L W 5.5'62.1 6.2 6.2 7'38.4 8 8 8'29.4 9.2 9.2 9'23.2 10.4 10.4 10'18.8 11.6 11.6 12'13.1 13.8 13.8 0ºD CONE OF LIGHT D FC L W 5.5'82.6 7 7 7'51 9 9 8'39.1 10.4 10.4 9'30.9 11.6 11.6 10'25 13 13 12'17.4 15.6 15.6 0ºD CANDELA TABLE Degrees Vertical Candela 0 6015 5 5909 15 4484 25 2725 35 1085 45 186 55 21 65 8 75 3 85 0 90 0 CANDELA TABLE Degrees Vertical Candela 0 7625 5 6969 15 3883 25 1822 35 727 45 87 55 8 65 3 75 0 85 0 90 0 CANDELA TABLE Degrees Vertical Candela 0 1880 5 1864 15 1763 25 1578 35 1329 45 1040 55 691 65 344 75 87 85 3 90 0 CANDELA TABLE Degrees Vertical Candela 0 2499 5 2528 15 2727 25 2670 35 1933 45 780 55 83 65 11 75 3 85 0 90 0 LUMINANCE Average Candela Degrees Average 0° Luminance 45 2844 55 400 65 205 75 113 85 0 LUMINANCE Average Candela Degrees Average 0° Luminance 45 1337 55 149 65 67 75 0 85 0 LUMINANCE Average Candela Degrees Average 0° Luminance 45 15933 55 13046 65 8819 75 3657 85 323 LUMINANCE Average Candela Degrees Average 0° Luminance 45 11948 55 1569 65 274 75 113 85 0 PHOTOMETRY LDRT4B EU4B 4LBW 4LBM 4LBN 01/24/2019 (1) Custom Skylight by A.I.A. Industries 4'-6" wide x 11'-1" long 2:12 pitch see specifications attached (2) Vellux Skylights E-Class Vented Deck Mount Model EVMS 4646 46 1/2" x 46 1/2" see specifications attached 15_323WHALLAM_SPEC SHEET_ROOF PLAN 01/24/2019 08630 - 1 A.I.A. Industries, Inc. SECTION 08630 290 E. 56th Avenue Denver, CO 80216 303.296.9696 Fx 303.296.2146 GENERAL SPECIFICATION DATA METAL FRAMED SKYLIGHTS PART 1 - GENERAL 1.01 SCOPE A. Design, and fabrication of entire skylight system to include all extruded aluminum framing, anchors, and flashing metals. B. Glazing and glazing materials including gaskets, sealants, setting blocks, backer rods, and related materials. C. Finish on metal components. D. Installation of the metal framed skylight system. 1.02 RELATED WORK A. Section 05120: Structural Steel. B. Section 05500: Metal Fabrications. C. Section 07620: Sheet Metal Flashing and Trim. D. Section 08800: Glazing. 1.03 REFERENCES A. American Architectural Manufacturers Association (AAMA). B. American Society for Testing and Materials (ASTM). C. Flat Glass Manufacturers Association (FGMA). 1.04 PERFORMANCE REQUIREMENTS A. Skylight system shall be designed to support loads as specified by local building codes for the location of the project, described and/or specified herein as: 1. Positive Live Loads: a. Snow Load..................PSF b. Wind Load..................PSF c. Dead Load....................lbs. 2 Negative Live Loads: a. Wind Load..................PSF 3. Load Combinations: a. Snow Load + Dead Load b. Wind Load + Dead Load 4. The maximum allowable deflection of any framing member normal to the plane of the glass 15_323WHALLAM_SPEC SHEET_SKYLIGHT - AIA 01/24/2019 METAL FRAMED SKYLIGHTS SECTION 08630 08630 - 2 shall not exceed L/175. Spans of 20' - 0" or greater shall not exceed a maximum allowable deflection of L/240. B. Manufacturer's system shall meet or exceed all performance standards as outlined by the following tests: 1. ASTM E283 (air infiltration) 2. ASTM E331 & AAMA 501(water penetration) 3. AAMA 1502.7 (condensation resistance) C. Thermal movement of system caused by ambient temperature ranges of + 70 degrees F without causing buckling, undue stress on structural elements, stresses on glass, failure of seals, performance reduction or other detrimental effects. 1.05 SUBMITTALS A. Shop drawings as required to fully describe the skylight system shall be submitted and approved by the architect prior to starting any fabrication. B. Finished aluminum samples (color charts or range samples), and glazing samples shall be submitted and approved by the architect prior to starting any fabrication. C. Submit manufacturer's written warranty as outlined in paragraph 1.07 of this specification. 1.06 QUALITY ASSURANCE A. The skylight manufacturer shall be responsible for the design, fabrication, and installation of the skylight assembly. B. Substitute manufacturer's will be considered only when all of the following conditions have been satisfied: 1. Alternate manufacturer's must be approved by architect to bid not less than twenty (20) days prior to bid date. 2. Detailed drawings for alternate skylight system are submitted to architect for review. 3. Structural calculations, showing sizes of framing members and loads applied to the support structure, based on the design loads of this specification are submitted for review. 4. Prospective manufacturer's must furnish evidence of their ability to perform, including a list of projects of similar design and complexity within the last ten (10) years. 5. Prospective skylight systems must be manufactured by a firm with a minimum of ten (10) years experience in the fabrication and installation of custom aluminum framed skylights. 1.07 WARRANTY A. The skylight system shall be warranted for a period of ( ____ ) year(s) after substantial completion against defects in materials and workmanship. B. All glazing shall be warranted pursuant to the glazing manufacturer's standard warranties. Glass breakage is not covered by these warranties. C. All aluminum finishes are warranted pursuant to the suppliers standard warranty. D. The structural sealant is warranted for ( ____ ) year(s) pursuant to the sealant manufacturer's standard warranty of merchantable quality. Warranty shall certify that cured sealant: 1. Shall not become brittle or crack due to weathering or normal expansion and contraction of adjacent surfaces. 2. Shall not harden nor soften beyond a Shore "A" durometer of 30 points. 3. Shall not change color significantly when used with compatible backup materials. 4. Shall not bleed significantly. 01/24/2019 METAL FRAMED SKYLIGHTS SECTION 08630 08630 - 3 PART 2 - PRODUCTS 2.01 MANUFACTURER A. Metal framed skylights shall be manufactured by: A.I.A. Industries, Inc. 290 East 56th Avenue Denver, Colorado, 80216 303.296-9696 Fax 303.296.2146 2.02 MATERIALS A. Framing members: 1. Extruded aluminum shall have minimum mechanical properties equal to or greater than 6063-T5 alloy and temper. 2. Snap on covers and miscellaneous non-structural trim shall be the minimum thickness recommended by the manufacturer. B. Flashing: 1. All formed aluminum sheet shall be the required alloy and temper to make compatible with the specified finish, with a minimum thickness of .040". C. Fasteners and Anchors: 1. Exposed fasteners shall be stainless steel or zinc coated, unless otherwise noted. D. Glazing Material: Thickness to be determined by codes, glazing area loading conditions and manufacturers recommendations. 1. Insulating glass unit consisting of 1/4 inch tempered (specify color and/or coating) exterior lite; 1/2 inch air space; and (___) inch clear (tempered) (laminated) (annealed interior lite with a .030 PVB interlayer) (heat strengthened interior lite with a (.030) (.060) PVB interlayer.) 2. Laminated glass unit consisting of: (___) inch (specify color and/or coating) laminated, heat strengthened glass with a (.030) (.060) PVB interlayer. 3. Insulating acrylic unit consisting of (___) inch (clear, bronze, or gray) exterior lite; 1/2 inch air space; (___) inch (clear or white) interior lite. The spacer bar shall allow for independent expansion and contraction of the interior and exterior lites. 4. (___) inch (polycarbonate) (acrylic) (double / triple wall) unit (specify color). E. Glazing Gaskets: 1. Extruded black E.P.D.M. meeting or exceeding the following: a. Hardness (Shore A) = 50 + durometer b. Tensile strenght = 2000 psi c. Elongation = 50% F. Sealants: 1. Selection of sealants shall be the responsiblity of the skylight manufacturer. 2. All surfaces shall be cleaned and primed within the sealant manufacturers guidelines. G. Finishes: 1. All exposed aluminum shall receive one or more of the following finishes (architect to select): a. Clear or Dark Bronze anodized. b. Powder Coated, (standard color). c. Acrylic enamel (custom color). d. Other: ________________________ 01/24/2019 METAL FRAMED SKYLIGHTS SECTION 08630 08630 - 4 2.03 FABRICATION A. Skylights shall be shop fabricated to the greatest extent possible. B. All welding shall be done by inert gas process, exposed welds to be ground and sanded smooth. C. System to be fabricated using integral condensate gutters and weep systems allowing any water penetration to drain to the outside. PART 3 - EXECUTION 3.01 INSTALLATION A. Metal framed skylights shall be installed by: A.I.A. Industries, Inc. 290 East 56th Avenue Denver, Colorado, 80216 303.296.9696 Fax 303.296.2146 B. A.I.A. Industries may authorize a third party to install the skylight. C. Prior to installation, installer, shall notify the general contractor of obvious deficiencies or dimensional errors in the support system and/or construction. No installation work shall proceed until all errors and deviations are corrected. Written authorization may be given to proceed with the as-built construction along with any price corrections. D. ADJACENT AND SUPPORT CONSTRUCTION MUST SUPPORT FORCE IMPOSED BY SKYLIGHT SYSTEM. E. Skylight materials shall be installed in strict accordance with manufacturer's installation instructions and drawings. F. Install skylights plumb, level and true to line, without warp or rack of frames or panels and anchor securely in place in accordance with approved shop drawings. G. Contact areas between dissimilar metals shall be isolated with a protective coating or plastic strip to prevent electrolytic corrosion. H. Upon completion of installation, installer shall remove all labels, part number markings and excess sealants from skylight components. Weep system shall be clear of any and all obstructions. 3.02 FINAL CLEANING A. Final cleaning and physical protection of all installed materials shall be the responsibility of the general contractor. END OF SECTION 01/24/2019   LABORATORY, FIELD TESTING AND ADVISORY SERVICES FOR THE BUILDING ENVELOPE 30 YEARS STRONG, UL AND CLEB SERVING CUSTOMERS ACROSS NORTH AMERICA CHICAGO US Headquarters 750 Anthony Trail Northbrook, IL 60062 chicago@cleb.com MONTREAL Canada Headquarters 1320 Lionel-Boulet Blvd Varennes, QC J3X 1P7 montreal@cleb.com QUEBEC 420 Charest East Blvd Suite 300 Quebec, QC G1K 8M4 quebec@cleb.com OTTAWA 29 Capital Drive Suite 200 Ottawa, ON K2G 0E7 ottawa@cleb.com TRURO 64 Inglis Place Suite 203 Truro, NS B2N 4B4 truro@cleb.com NEW YORK 747 Third Avenue 2nd Floor New York, NY 10017 newyork@cleb.com T: 855.353.2532 W: ul.com/buildingenvelope        SIMULATION TEST REPORT FOR U-FACTOR/SHGC/VT/CR REPORT No: 4788305776 CLIENT: AiA Industries 290 E. 56th Avenue Denver, CO 80216 PRODUCT TYPE: Single Slope Skylight Glazing U-factor SHGC VT CR Triple-Pane. With 100% Air-Filled Cavity 0.38 Btu/hr-ft2-ºF 0.20 0.36 63 Triple-Pane. With 90% Argon/10% Air-Filled Cavity 0.35 Btu/hr-ft2-ºF 0.20 0.36 64 *Dual-Pane. With 100% Air-Filled Cavity 0.52 Btu/hr-ft2-ºF 0.23 0.40 60 *Dual-Pane. With 90% Argon/10% Air-Filled Cavity 0.47 Btu/hr-ft2-ºF 0.23 0.40 64 * Note: 2nd revision. Two rows added to include dual-pane IG options. Simulation Test Date: 02/05/2018, 03/26/2018 Report Date: 02/10/2018 Report Revision 1: 02/23/2018 Report Revision 2: 03/27/2018 01/24/2019   AiA Industries Report Date: 02/10/2018 Page 2 Revision 2 Date: 03/27/2018 1.0 Summary of Results Issued To: AiA Industries 290 E. 56th Avenue Denver, CO 80216 2.0 Test Laboratory: UL LLC Northbrook, Illinois 60062 3.0 Project Summary: 3.1 Product Type: Skylight 3.2 Series/Model: Single Slope 3.3 Compliance Statements: Results obtained are simulated values for U-factor, Solar Heat Gain Coefficient (SHGC), Visible Transmittance (VT), and Condensation Resistance (CR) and were secured by using the designated NFRC test method(s) in full compliance. Test specimen description and results are reported herein. This report may not be reproduced, except in full, without the written approval of UL, LLC. 3.4 Simulation Date: 02/05/2018, 03/26/2018 3.5 NFRC Test Methods: ANSI/NFRC 100-2017, Procedure for Determining Fenestration Product U-factors ANSI/NFRC 200-2017, Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence NFRC 500-2017 Procedure for Determining Fenestration Product Condensation Resistance Value 3.6 Software Used: Berkeley Lab WINDOW 7.4 THERM 7.4 3.7 Test Source and Retention: The product line simulated were based on drawings submitted by the client. Simulation report, data, and drawings will be retained by UL LLC for a minimum of five years from the test completion date.   4.0 Specimen Description: Specimen Specimen Description NFRC Model Sizes 1200mm x 1200mm (47.2" x 47.2")      01/24/2019   AiA Industries Report Date: 02/10/2018 Page 3 Revision 2 Date: 03/27/2018     Specimen Description (Continued):   Frame The frame was comprised of aluminum-alloy members exterior and interior members separated extruded polystyrene insulation. The wood curb was four (4) 2x4 hardwood members combined. Glazing Systems 1-7/8" overall triple-glazed system: Exterior lite was 6mm PPG Solarban 100 LowE (surface #2) *Air gap was 0.500" with 100% Air or 90%/10% Argon-Air Mix Center lite was 6mm Clear Air gap was 0.500" with 100% Air or 90%/10% Argon-Air Mix Interior lite was clear Guardian laminate comprised of 4mm glass/0.060" PVB interlayer/4mm glass. *1-1/8" overall dual-glazed system: Exterior lite was 6mm PPG Solarban 100 LowE (surface #2) *Air gap was 0.500" with 100% Air or 90%/10% Argon-Air Mix Center lite was 6mm Clear Interior lite was clear Guardian laminate comprised of 4mm glass/0.060" PVB interlayer/4mm glass.   Spacer System Steel spacer with a secondary seal of hot-melt butyl. * Revised Items in this report 5.0 Test Results: Glazing U-factor SHGC VT CR Triple-Pane. With 100% Air-Filled Cavity 0.38 Btu/hr-ft2-ºF 0.20 0.36 63 Triple-Pane. With 90% Argon/10% Air-Filled Cavity 0.35 Btu/hr-ft2-ºF 0.20 0.36 64 *Dual-Pane. With 100% Air-Filled Cavity 0.52 Btu/hr-ft2-ºF 0.23 0.40 60 *Dual-Pane. With 90% Argon/10% Air-Filled Cavity 0.47 Btu/hr-ft2-ºF 0.23 0.40 64 * Note: 2nd revision. Two rows added to include dual-pane IG options. 6.0 Modeling Assumptions and Technical Notes - Skylight results were calculated at a slope of 20° above horizontal as required per ANSI/NFRC 100. 01/24/2019   AiA Industries Report Date: 02/10/2018 Page 4 Revision 2 Date: 03/27/2018   Appendix A: Assembly Drawings of Single Slope Skylight Appendix B: Revision Log For UL LLC: Dennis Anderson NFRC Certified Simulator Program/Project Manager 01/24/2019   AiA Industries Report Date: 02/10/2018 Page 5 Revision 2 Date: 03/27/2018   Appendix A: Assembly Drawings of Single Slope Skylight 01/24/2019   AiA Industries Report Date: 02/10/2018 Page 6 Revision 2 Date: 03/27/2018   01/24/2019   AiA Industries Report Date: 02/10/2018 Page 7 Revision 2 Date: 03/27/2018   01/24/2019   AiA Industries Report Date: 02/10/2018 Page 8 Revision 2 Date: 03/27/2018   01/24/2019   AiA Industries Report Date: 02/10/2018 Page 9 Revision 2 Date: 03/27/2018   Appendix B Revision Records 02/23/2018: Report revised to add an Argon Gas option to the glazing cavity. Because of this revision, it was noticed that the CR for the initial report had a type error and was corrected to read 63. See asterisk items. 03/27/2018: Report revised to add dual-glazed options to skylight. Description and results tables updated. 01/24/2019 OPERABLE UNIT SKYLIGHTS 06_2018 08620 deck mounts 1 SECTION 08620 E-CLASS VENTED DECK MOUNT SkyWindow® PART 1-GENERAL 1.1 SUMMARY A. This section includes the following: 1. Model EV: E-Class deck mount manual vent glass glazed unit skylights. 2. Model EVMS: E-Class deck mount solar power motorized vent glass glazed unit skylights. 1.2 REFERENCE STANDARDS A. ASTM E 283 – Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specific Pressure Differences Across the specimen. B. ASTM E 330 – Standard Test Method for Structural Performance of Exterior Windows, and Doors Skylights and Curtain Walls by Uniform Static Air Pressure Difference. C. ASTM E 331 – Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference. D. North American Fenestration Standard (NAFS) AAMA\WDMA\CSA\101\I.S.2\A440. E. National Fenestration Rating Council, NFRC 100, Procedure for Determining Fenestration Product U-factors. F. National Fenestration Rating Council, NFRC 200, Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence. 1.3 PERFORMANCE REQUIREMENTS A. General: Provide unit skylights capable of withstanding loads as defined by the local codes having jurisdiction where units are to be installed without failure. B. Units shall be tested to compliance with AAMA\WDMA\CSA\101\I.S.2\A440 as required by the International Building Code. C. Provide units tested to AAMA\WDMA\CSA\101\I.S.2\A440 with the following rating: SKG-PG40 1295 x 1295 (51 x 51). D. Water Infiltration: No uncontrolled leakage when tested in accordance with ASTM E331 at a test pressure of 15 psf. E. Air Infiltration: Air leakage shall not exceed 0.01 cfm per square foot of surface area when tested in accordance with ASTM E283 at differential static pressure of 1.57 psf. F. Thermal Performance: Provide full system NFRC certified performance as follows: 1. eMAX3: U-factor = 0.49, SHGC = 0.25, VT = 58% 2. eMAX3 laminated: U-factor = 0.48, SHGC = 0.25, VT = 57% 3. Triple Glaze 30-30: U-factor = 0.33, SHGC = 0.22, VT = 42% 15_323WHALLAM_SPEC SHEET_SKYLIGHT - VELLUX 01/24/2019 OPERABLE UNIT SKYLIGHTS 06_2018 08620 deck mounts 2 1.4 SUBMITTALS A. Product Data Sheet: For each type of skylight specified, include details of construction and installation, relative to applicable roofing materials. B. Samples for Selection: Manufacturer’s color charts showing a full range of colors available for each type of skylight glazing and aluminum finish. 1.5 WARRANTY A. General: Warranties specified in this section shall not deprive the Owner of other rights the Owner may have under other provisions of the Contract Documents and shall be in addition to and run concurrent with other warranties made by the Contractor under requirements of the Contract Documents. B. Skylight Warranty: Provide written warranty signed by manufacturer, agreeing to repair or replace work that exhibits defects in materials or workmanship and guaranteeing weather-tight and leak-free performance. “Defects” is defined as uncontrolled leakage of water and abnormal aging or deterioration. 1. Warranty Period: 10 years from original date of purchase. C. Glass Warranty: Provide written warranty signed by manufacturer agreeing to repair or replace work that has or develops defects in the insulating glass. “Defects” is defined as seal failure. 1. Warranty Period for Insulating Glass: 20 years from date of original purchase. D. Finish Warranty: Provide written warranty signed by manufacturer agreeing to repair or replace work with finish defects. “Defects” is defined as peeling, chipping, chalking, fading, abnormal aging or deterioration, and failure to perform as required. 1. Warranty Period for Powder Coat Finish: 10 years from date of Substantial Completion. PART 2- PRODUCTS 2.1 MANUFACTURERS A. Manufacturers: Subject to compliance with requirements, provide products by Wasco Skylights / part of the Velux Group, Wells, ME 04090, (800-388-0293). B. Substitutions: Not Permitted. 2.2 MATERIALS A. Curb Frame: Bright white high-performance ridge PVC with Bronze cap stock, coextruded with soft vinyl flashing. Provide integral condensation gutter system with corners fully welded for waterproof quality. B. Retainer Frame: Extruded aluminum alloy 6063-T5 (min). ASTM B 221 (ASTM B 221 M) with minimum effective thickness of 0.060 inch (1.5 mm). The aluminum retaining frame is mitered and secured using an aluminum staking corner key. Quaker Bronze powder coat finish. C. Thermal Break: Fabricate skylight units with thermal chambered PVC frame. D. Fasteners: Non-magnetic stainless steel or other non-corrosive metal as recommended by manufacturer. E. Insulating Glass: 1. eMAX3: Clear tempered Low-E outer, argon filled airspace, clear tempered inner pane. 2. eMAX3 laminated: Clear tempered Low-E outer, argon filled airspace, heat strengthened laminated inner pane. 3. Triple Glazed 30- 30: Clear tempered Low-E outer, argon airspace, clear tempered middle pane, argon airspace, clear tempered Low-E inner pane. F. Lumira Aerogel: 25 mm Multi-wall flat cellular polycarbonate panel filled with Lumira™ aerogel insulation material. 01/24/2019 OPERABLE UNIT SKYLIGHTS 06_2018 08620 deck mounts 3 2.3 OPERATORS A. Model EV: WLS Manual Operator standard with hand crank or eye hook for pole operation. a. Options: i. Skylight Pole ii. WLS Motor Kit: includes wall mount switch and rain sensor. Motor mounts over existing manual operator. iii. WLS Remote Control B. Model EVMS: Solar Powered Electric Operator, includes one remote control per unit. 2.4 FABRICATION A. Framing Components: As follows: 1. Factory fit and assemble components. 1. Fabricate components that, when assembled, will have accurately fitted joints with ends coped or mitered. 2. Fabricate components to accommodate expansion, contraction, and field adjustment, and to provide for minimum clearance and shimming at skylight perimeter. 3. Fit and secure PVC frame joints by thermal welding. 4. Fit and secure aluminum retainer joints with corner keys. 5. No site fabrication required. 2.5 ALUMINUM FINISHES (EDIT AS REQUIRED) A. General: Comply with NAAMM “Metal Finishes Manual” recommendations for application and designations of finishes. B. Finish designations prefixed by AA conform to the system for designations of aluminum finishes established by the Aluminum Association. 1. Powder Coat High-Performance Architectural Coating: comply with AAMA 2604. Color:______________ (contact manufacturer for color options) 2. Copper Cladding PART 3- EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions, with installer present, for compliance with requirements for installation tolerances and other conditions affecting skylight performance. 1. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. General: Comply with manufacturer’s written instructions for protecting, handling, and installing skylight components. 3.3 CLEANING AND PROTECTION A. Clean exposed metal and glass surfaces according to manufacturer’s instructions. Touch up damaged metal coatings. B. Protect skylight surfaces from ongoing construction. C. Final cleaning by others. END OF SECTION 01/24/2019 VMS (VELUX Modular Skylight) Thermal and Other Testing Technical Data July 2016  Glazing Type Glazing Description Module Type U-Factor arg/xenon SHGC VT clr/wht Low Energy Dual Pane at 20° above horiz. 8mm Temp exterior with Lami interior Fixed (HFC) 0.34/0.25 0.46 0.64/0.46 Low Energy Dual Pane at vertical 8mm Temp exterior with Lami interior Fixed (HFC) 0.28/0.23 0.46 0.64/0.46 Low Energy with HanGlas Dual Pane at 20° 8mm Temp exterior with Lami interior Fixed (HFC) 0.33/0.24 0.25 0.46/0.33 Low Energy with HanGlas Dual Pane at vert. 8mm Temp exterior with Lami interior Fixed (HFC) 0.27/0.22 0.24 0.46/0.33 Super Low Energy Triple Pane at 20° 8mm Temp, 8mm center and Lami interior Fixed (HFC) 0.21/ - 0.36 0.55/0.40 Super Low Energy Triple Pane at vert. 8mm Temp, 8mm center and Lami interior Fixed (HFC) 0.16/ - 0.36 0.56/0.40 Low Energy Dual Pane at 20° above horiz. 8mm Temp exterior with Lami interior Venting (HVC) 0.35/0.25 0.46 0.64/0.46 Low Energy Dual Pane at vertical 8mm Temp exterior with Lami interior Venting (HVC) 0.29/0.24 0.46 0.64/0.46 Low Energy with HanGlas Dual Pane at 20° 8mm Temp exterior with Lami interior Venting (HVC) 0.34/0.24 0.24 0.46/0.33 Low Energy with HanGlas Dual Pane at vert. 8mm Temp exterior with Lami interior Venting (HVC) 0.28/0.24 0.24 0.46/0.33 Super Low Energy Triple Pane at 20° 8mm Temp, 8mm center and Lami interior Venting (HVC) 0.22/ - 0.36 0.55/0.40 Super Low Energy Triple Pane at vert. 8mm Temp, 8mm center and Lami interior Venting (HVC) 0.17/ - 0.36 0.56/0.40 Tested in accordance with NFRC requirements per standards NFRC 100-2010, NFRC 200-2010 and NFRC 500-2010 37 28 Passed 40 34 HFC Module Type 11 Glazing 1m x 2.4m 1200 lb-ft HFC Module Type 11T Glazing 1m x 3m 1200 lb-ft 400 lbs 500° C 410° C 7.0 Class CC1 3,925.7 lbs. 1,260 lbs. 3,243.8 lbs. 1,545 lbs. HFC/HVC Module Type 16T Glazing 1m x 1.8m Acoustics Testing per ASTM E 90 and ASTM E 413 STC (Interior Noise) Acoustics Testing per ASTM E 90 and ASTM E 1332 OITC (Exterior Noise) Linear Rate of Burn ASTM D 635 Average Maximum Allowable Load Bracket Loads (Ridgelight, Longlight and lower Northlight) Loaded In-Line Loaded at 45° angle Average Maximum Allowable Load OSHA Fall Resistance test where 200 lb weight dropped from 6 ft height with no damage to panes to comply with OSHA 29CFR 1910.23(e)(8) OSHA Fall Resistance Self Ignition Temperature ASTM D 1929 Flash Ignition Temperature ASTM D 1929 Average Smoke Density Rating ASTM D 2843 OSHA Fall Resistance test where 200 lb weight was dropped from 6 ft height with no damage to comply with OSHA 29CFR 1910.23(e)(8), and CalOSHA Fall Resistance test where 400 lb weight was resisted for 60 seconds per CCR Title 8, Section 3212 OSHA Fall Resistance CalOSHA Fall Resistance VMS Product Performance - Other Test Results Acoustics Testing per ASTM E 90 and ASTM E 413 STC (Interior Noise) Acoustics Testing per ASTM E 90 and ASTM E 1332 Burning Brand Test ASTM E 108 OITC (Exterior Noise) Class B Burning Brand VMS Modules - Thermal Performance Test Results HFC/HVC Module Type 11 Glazing 1m x 2.4m Pultruded Composite VMS Frame Type 10 Type 11 Type 16 Type 10 Type 11 Type 16 01/24/2019