HomeMy WebLinkAboutFile Documents.323 W Hallam St.0015.2019 (7).ARBKSPECIFICATION FEATURES
Lower Shielding Reflector
Painted die cast aluminum or spun
aluminum lower reflector with
a lensed upper optical chamber
providing superior lumen output
with minimal source brightness.
Spun reflectors are offered in all
Portfolio Alzak® finishes. Available
with non-conductive polymer
trim. Reflector is retained with two
torsion springs holding the flange
tight to the finished ceiling surface.
Plaster Frame / Collar
Galvanized steel ring installs with
2 mouse trap springs for secure
installation and accommodates up
to 2 inch ceiling thickness.
Retrofit - Converts existing
HID, incandescent or compact
fluorescent downlights to energy
saving LED. Simple below ceiling
installation without removing the
existing fixture. Pre-wired flexible
conduit with snap in connector
installs into 1/2” knockout on the
existing junction box.
Thermal
Aluminum heat sink conducts heat
away from the LED module for
optimal performance and long life.
LED
Chip on board with a multitude
of highly efficient white LED’s,
combined with a high reflectance
upper reflector and convex
transitional lens produce even
distribution with no pixilation.
Rated for 50,000 hours at 70%
lumen maintenance. Auto
resetting, thermally protected,
LED’s are turned off when safe
operating temperatures are
exceeded. Color variation within
3-step MacAdam ellipses. Quick
disconnect allows for tool-less
replacement of LED engine from
below ceiling. Available in 80, 90
or 97 CRI.
D2W™ – dim-to-warm shifts CCT
from 3000K to1850K as fixture dims
mimicking halogen sources.
W2N - Tunable white CCT range
2700K to 6500K or 2000K to 5000K,
90 CRI.
Driver
Standard 120-277V 0-10V
dimming driver provides flicker
free dimming from 100% to 1%.
Optional 120V leading edge,
<1% 0-10V, Fifth Light, DMX or
Lutron® Ecosystem. Driver can be
serviced from above or through the
aperture.
Connected Lighting Systems
WaveLinx tilemount daylight
sensor includes control module,
sensor and cable allowing use
with the comprehensive lighting
system.
LumaWatt Pro (powered by
Enlighted) wireless tile mount
sensor and relay accessory enables
wireless control using a tile mount
sensor accessory.
Code Compliance
Thermally protected and cULus
listed for wet locations with
covered ceiling. IP66 rated
when used with IP66 gasket kit
accessory. Optional City of Chicago
environmental air (CCEA) marking
for plenum applications. EMI/RFI
emissions per FCC 47CFR Part
18 Class B consumer limits. 2000
lumens and above are Non-IC
rated - Insulation must be kept 3”
from top and sides of housing.
IC rated up to 1500 lumens. 5000
lumen and above are marked
spacing and must follow spacing
requirements. RoHS Compliant.
Photometric testing completed in
accordance with IES LM 79 and
TM-30 standards. LED life testing
completed in accordance with LM
80 standards.
Warranty
5-year warranty
LDRT4B EU4B
4LBW 4LBM
4LBN
1000-6000 Lumen LED
STEPREPEAT>
Narrow, Medium, or Wide Beam
International, Remodel, Retrofit
4-inch recessed LED for international, remodel or retrofit applications.
Offered with narrow, medium, or wide beam reflectors designed for
glare free even illumination. Featuring a two-stage diffused reflector
system producing smooth distribution with excellent light control and
low aperture brightness. Lumen packages range from 1000 to 6000 with
color temperatures of 2400K, 2700K, 3000K, 3500K, 4000K, and 5000K.
VividTune: Dim-to-warm technology – similar to halogen at full power,
the 3000K LED warms smoothly as dimmed to 1850K creating a rich
warm glow within the space. Tunable white technology - adjust the
color temperature from warm white to cool white while independently
controlling intensity.
DESCRIPTION
Refer to ENERGY STAR® Qualified
Products List. Can be used to comply
with California Title 24 High Efficacy
requirements. Certified to California
Title 20 Appliance Efficiency Database.
4-3/4" MIN[122mm MIN]5-3/16" MAX[132mm MAX]
5-11/16"[144mm]
9-7/8"[251mm]
MAX HEIGHT(SEE TABLE)1/2" MIN[13mm MIN]
2" MAX[51mm MAX]
1000-2000 LUMENS 3000-5000 LUMENS 6000 LUMENS
NARROW / MEDIUM 5-1/4" [133mm]5-1/4" [133mm]7" [178mm]
WIDE / WALL WASH 4-3/4" [121mm]4-3/4" [121mm]6-1/2" [165mm]
SHALLOW 3-1/2" [89mm]3-1/2" [89mm]NA
12-7/8"[328mm]20-3/16"[514mm]
5-1/2"[132mm]
3-9/16"[93mm]
2-1/16"[54mm]2-3/4"[70mm]
7-1/16"[180mm]
6-7/8"[176mm]
5-7/8"[149mm]
TD520036EN
October 5, 2018 8:44 AM
Portfolio
Catalog #Type
Project
Comments Date
Prepared by
LDRT4B-15-D010
323 W. HALLAM ST.
15_323WHALLAM_SPEC SHEET_LED RECESSED LIGHT
01/24/2019
LDRT4B EU4B 4LBW 4LBM 4LBN
ORDERING INFORMATION
ENERGY DATA
Sound Rating: Class A standards
(Values at non-dimming line voltage)
Minimum Starting Temperature: -30°C (-22°F)
EMI/RFI: FCC Title 47 CFR, Part 15, Class B (Consumer)
Input Voltage: UNV (120V - 277V)
Power Factor: >0.90 (at nominal input 120-277 VAC & 100% of Rated Output Power)
Input Frequency: 50/60Hz
1000 Lumen D010 1500 Lumen D010
Input Power: 11W THD: <14%Input Power: 15.5W THD: <13%
120V Input Current: 0.09A 277V Input Current: 0.04A 120V Input Current: 0.13A 277V Input Current: 0.06A
2000 Lumen D010 3000 Lumen D010
Input Power: 21.2W THD: <9%Input Power: 27.6W THD: <10%
120V Input Current: 0.18A 277V Input Current: 0.08A 120V Input Current: 0.23A 277V Input Current: 0.10A
4000 Lumen D010
Input Power: 41.6W THD: <13%
120V Input Current: 0.35A 277V Input Current: 0.15A
120V 277V
Lumens Inrush (A)Duration (ms)Inrush (A)Duration (ms)
1000 Lumen D010 1.02 0.041 2.18 0.021
1500 Lumen D010 1.02 0.042 2.24 0.064
2000 Lumen D010 1.02 0.077 2.43 0.027
3000 Lumen D010 1.15 0.067 3.26 0.027
4000 Lumen D010 1.2 0.088 3.9 0.03
ENERGY
SAMPLE NUMBER: LDRT4B15D010EMBOD
Housing Lumens1 Voltage Driver Options3
LDRT4B=LED Downlight
Retrofit 4” Nominal
Aperture
LDRT4BCP=LED Downlight
Retrofit 4” Nominal
Aperture, Chicago
Plenum
10=1000 lumens
15=1500 lumens
20=2000 lumens
30=3000 lumens
40=4000 lumens
50=5000 lumens16
60=6000 lumens16
Blank=120-277V
3=347V (step down
transformer)
1000 - 4000 Lumen
D010=0-10V Dimming, 1% to 100%, 120V-277V
D010TR=0-10V or Line Voltage Dimming, 5% to 100%, 120V-277V
DE010=0-10V Dimming, 0% to 100%, 120V-277V
D5LT=Fifth Light® (DALI) Dimming, 0% to 100%, 120V-277V
DMX=DMXRDM Dimming, 0% to 100%, 120V-277V14
DL2=Lutron® Hi-Lume Forward Phase Dimming, 1% to 100%, 120V Only
DL3=Lutron® Hi-Lume 3 Wire Dimming, 1% to 100%, 120V-277V
DLE=Lutron Ecosystem dimming 1% to 100%, 120V-277V
5000-6000
D010TE=0-10V 1% or trailing edge 10%, 120-277V (120V only with trailing
edge dimming)
Tunable white 1000-2000 Lumens18
1DE010W2N2050=0-10V dimming, 0% to 100%, 120V, 2000K - 6500K
1DE010W2N2765=0-10V dimming, 0% to 100%, 120V, 2700K - 5000K
1D5LTW2N2050=Fifth Light (DALI), 0% to 100%, 120, 2000K - 6500K
1D5LTW2N2765=Fifth Light (DALI), 0% to 100%, 120V, 2700K - 5000K
2DE010W2N2050=0-10V dimming, 0% to 100%, 277V, 2000K - 6500K
2DE010W2N2765=0-10V dimming, 0% to 100%, 277V, 2700K - 5000K
2D5LTW2N2050=Fifth Light (DALI), 0% to 100%, 277V, 2000K - 6500K
2D5LTW2N2765=Fifth Light (DALI), 0% to 100%, 277V, 2700K - 5000K
EMBOD=Bodine® Emergency
Module with Remote Test
Switch3
EM7=7W Emergency Module with
Remote Test Switch3, 10
EM14=14W Emergency Module
with Remote Test Switch3, 10
SWPD1=Factory installed
WaveLinx tilemount daylight
sensor (includes control
module, sensor, cable, and
tile mount)3, 15
LWTPD1=Factory installed
LumaWatt Pro wireless sensor
kit3, 15
SAMPLE NUMBER: EU4B10208035
Power Module Lumen Levels1 CRI Color
EU4B=4” Universal LED
Module
1020=1000, 1500, 2000
lumens
3040=3000-4000 lumens14
5000=5000 lumens16
6000=6000 lumens16
1015IC=1000, 1500 lumen
IC rated
80=80 CRI Minimum
90=90 CRI Minimum
97=97 CRI Minimum
80 CRI
27=2700K
30=3000K
35=3500K
40=4000K
50=5000K
90 CRI
24=2400K
27=2700K
30=3000K
35=3500K
40=4000K
50=5000K
97 CRI
27=2700K
30=3000K
Dim 2 Warm
109030D2W=1000 lumen, 90 CRI, Dim 2 Warm, IC rated
159030D2W=1500 lumen, 90 CRI, Dim 2 Warm, IC rated
209030D2W=2000 lumen, 90 CRI, Dim 2 Warm
309030D2W=3000 lumen, 90 CRI, Dim 2 Warm
Tunable white18
1020W2N902050 =1000, 1500, 2000 lumens, 90 CRI, tunable white 2000K-5000K
1020W2N902765 =1000, 1500, 2000 lumens, 90 CRI, tunable white 2700K-6500K
SAMPLE NUMBER: 4LBM1LI
Trim Distribution4 Flange Finish
4LB=4” LED N=Narrow (25° Beam), Spun Aluminum
M=Medium (50° Beam), Spun Aluminum
W=Wide (75° Beam), Spun Aluminum
S=Shallow (75° Beam), Spun Aluminum 17
PS=Non-conductive Shallow (75° Beam), Injection Molded white11, 12
CS=Cast Shallow (75° Beam), Die Cast Aluminum12
BA=Baffle, Spun Aluminum5
0=White Polymer Trim Ring
1=Self-flanged13
2=White Painted Self-flanged
LI=Specular Clear7
H=Semi-Specular Clear7
WMH=Warm Haze7
WH=Wheat7
GPH=Graphite Haze7
B=Specular Black7
MW=Matte White
MB=Matte Black8
MMS=Matte Metallic Silver9
Accessories
TRM4=Metal Trim Ring, Specify Color2
TRR4=Rimless Trim Ring2
LGSKT4IP66=IP66 Gasket Kit
Connected Lighting Systems
PORLWTPD1=LumaWatt Pro wireless sensor kit (0-10V only) field installed15
TMSWPD1=WaveLinx tilemount daylight sensor (includes control module,
sensor, cable and tile mount field installed15
Notes:
1 Nominal Lumens will vary depending on selected
color, driver and reflector finish.
2 Order trim with polymer trim ring (Consult
specification sheet for color ordering information and
options).
3 Not available with Chicago Plenum.
4 Beam angles are nominal with LI finish trims.
5 Only available with Matte White and Matte
Black Finishes.
6 Available only on PS, CS, and BA distributions.
7 Not available on PS, CS or BA distributions.
8 Available on CS and BA distributions
9 Available on CS distributions
10 ULus listed only
11 PS available in self flange matte white only
12 Offered up to 2000 lumens
13 Flange is the same finish as the reflector.
14 DMX fixtures default to full on upon loss of
DMX signal.
15 Refer to system specifications for additional
information, features, and benefits.
Order either factory installed option or accessory.
Use with 0-10V driver.
16 Product is marked spacing and must be installed
with the following minimum spacing
- Center to center of adjacent luminaires: 36”
- Center of luminaire to side of building member: 18”
- Minimum overhead: ½”
17 Offered up to 4000 lumens
18 Non-IC
01/24/2019
Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
CANDLEPOWER DISTRIBUTION
Downlight
697
1395
2092
2790 15º30º
45º
60º
75º
90º
CANDLEPOWER DISTRIBUTION
Downlight
567
1134
1706
2267 15º30º
45º
60º
75º
90º
CANDLEPOWER DISTRIBUTION
Downlight
254
508
762
1016 15º30º
45º
60º
75º
90º
CANDLEPOWER DISTRIBUTION
Downlight
172
344
516
688 15º30º
45º
60º
75º
90º
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30 1144 77.3
0-40 1406 95
0-60 1477 99.7
0-90 1481 100
90-180 0 0
0-180 1481 100
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30 926 82.1
0-40 1094 97
0-60 1127 99.9
0-90 1128 100
90-180 0 0
0-180 1128 100
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30 512 34.2
0-40 816 54.5
0-60 1333 89
0-90 1497 100
90-180 0 0
0-180 1497 100
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30 816 53.8
0-40 1252 82.5
0-60 1513 99.7
0-90 1518 100
90-180 0 0
0-180 1518 100
MEDIUM (50° BEAM)
Test
Number P201206
Housing LD4B15D010
Module EU4B10208035
Trim 4LBM1LI
Lumens 1481
Efficacy 103.6 Lm/W
SC 0.71
NARROW (25° BEAM)
Test
Number P201208
Housing LD4B15D010
Module EU4B10208035
Trim 4LBN1LI
Lumens 1128
Efficacy 78.9 Lm/W
SC 0.5
SHALLOW (75° BEAM)
Test
Number P201210
Housing LD4B15D010
Module EU4B10208035
Trim 4LBCS1MMS
Lumens 1497
Efficacy 104.7 Lm/W
SC 1.16
WIDE (75° BEAM)
Test
Number P201204
Housing LD4B15D010
Module EU4B10208035
Trim 4LBW1LI
Lumens 1518
Efficacy 106.2 Lm/W
SC 1.3
CONE OF LIGHT
D FC L W
5.5'74.9 3.8 3.8
7'46.3 5 5
8'35.4 5.6 5.6
9'28 6.4 6.4
10'22.7 7 7
12'15.7 8.4 8.4
0ºD
CONE OF LIGHT
D FC L W
5.5'92.2 2.6 2.6
7'56.9 3.4 3.4
8'43.6 3.8 3.8
9'34.4 4.4 4.4
10'27.9 4.8 4.8
12'19.4 5.8 5.8
0ºD
CONE OF LIGHT
D FC L W
5.5'22.7 6.2 6.2
7'14 8 8
8'10.7 9.2 9.2
9'8.5 10.4 10.4
10'6.9 11.6 11.6
12'4.8 13.8 13.8
0ºD
CONE OF LIGHT
D FC L W
5.5'30.2 7 7
7'18.7 9 9
8'14.3 10.4 10.4
9'11.3 11.6 11.6
10'9.1 13 13
12'6.4 15.6 15.6
0ºD
CANDELA TABLE
Degrees
Vertical Candela
0 2267
5 2227
15 1690
25 1027
35 409
45 70
55 8
65 3
75 1
85 0
90 0
CANDELA TABLE
Degrees
Vertical Candela
0 2790
5 2550
15 1421
25 667
35 266
45 32
55 3
65 1
75 0
85 0
90 0
CANDELA TABLE
Degrees
Vertical Candela
0 688
5 682
15 645
25 577
35 486
45 380
55 253
65 126
75 32
85 1
90 0
CANDELA TABLE
Degrees
Vertical Candela
0 914
5 925
15 998
25 977
35 707
45 286
55 30
65 4
75 1
85 0
90 0
LUMINANCE
Average
Candela
Degrees
Average
0°
Luminance
45 1072
55 151
65 77
75 42
85 0
LUMINANCE
Average
Candela
Degrees
Average
0°
Luminance
45 489
55 55
65 26
75 0
85 0
LUMINANCE
Average
Candela
Degrees
Average
0°
Luminance
45 5827
55 4771
65 3226
75 1339
85 124
LUMINANCE
Average
Candela
Degrees
Average
0°
Luminance
45 4372
55 574
65 100
75 42
85 0
PHOTOMETRY
LDRT4B EU4B 4LBW 4LBM 4LBN
01/24/2019
Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
CANDLEPOWER DISTRIBUTION
Downlight
1906
3813
5719
7625 15º30º
45º
60º
75º
90º
CANDLEPOWER DISTRIBUTION
Downlight
1504
3007
4511
6015 15º30º
45º
60º
75º
90º
CANDLEPOWER DISTRIBUTION
Downlight
694
1388
2081
2775 15º30º
45º
60º
75º
90º
CANDLEPOWER DISTRIBUTION
Downlight
470
940
1410
1880 15º30º
45º
60º
75º
90º
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30 3036 77.3
0-40 3731 95
0-60 3918 99.7
0-90 3929 100
90-180 0 0
0-180 3929 100
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30 2531 82.1
0-40 2989 97
0-60 3080 99.9
0-90 3083 100
90-180 0 0
0-180 3083 100
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30 1400 34.2
0-40 2230 54.5
0-60 3645 89
0-90 4093 100
90-180 0 0
0-180 4093 100
ZONAL LUMEN SUMMARY
Zone Lumens % Fixture
0-30 2230 53.8
0-40 3421 82.5
0-60 4134 99.7
0-90 4148 100
90-180 0 0
0-180 4148 100
MEDIUM (50° BEAM)
Test
Number P201207
Housing LD4B40D010
Module EU4B30408035
Trim 4LBM1LI
Lumens 3929
Efficacy 94 Lm/W
SC 0.71
NARROW (25° BEAM)
Test
Number PP201209
Housing LD4B40D010
Module EU4B30408035
Trim 4LBN1LI
Lumens 3083
Efficacy 73.8 Lm/W
SC 0.5
SHALLOW (75° BEAM)
Test
Number P201211
Housing LD4B40D010
Module EU4B30508035
Trim 4LBCS1MMS
Lumens 4093
Efficacy 97.9 Lm/W
SC 1.16
WIDE (75° BEAM)
Test
Number P201205
Housing LD4B40D010
Module EU4B30408035
Trim 4LBW1LI
Lumens 4148
Efficacy 99.2 Lm/W
SC 1.3
CONE OF LIGHT
D FC L W
5.5'198.8 3.8 3.8
7'122.7 5 5
8'94 5.6 5.6
9'74.3 6.4 6.4
10'60.1 7 7
12'41.8 8.4 8.4
0ºD
CONE OF LIGHT
D FC L W
5.5'252.1 2.6 2.6
7'155.6 3.4 3.4
8'119.1 3.8 3.8
9'94.1 4.4 4.4
10'76.2 4.8 4.8
12'53 5.8 5.8
0ºD
CONE OF LIGHT
D FC L W
5.5'62.1 6.2 6.2
7'38.4 8 8
8'29.4 9.2 9.2
9'23.2 10.4 10.4
10'18.8 11.6 11.6
12'13.1 13.8 13.8
0ºD
CONE OF LIGHT
D FC L W
5.5'82.6 7 7
7'51 9 9
8'39.1 10.4 10.4
9'30.9 11.6 11.6
10'25 13 13
12'17.4 15.6 15.6
0ºD
CANDELA TABLE
Degrees
Vertical Candela
0 6015
5 5909
15 4484
25 2725
35 1085
45 186
55 21
65 8
75 3
85 0
90 0
CANDELA TABLE
Degrees
Vertical Candela
0 7625
5 6969
15 3883
25 1822
35 727
45 87
55 8
65 3
75 0
85 0
90 0
CANDELA TABLE
Degrees
Vertical Candela
0 1880
5 1864
15 1763
25 1578
35 1329
45 1040
55 691
65 344
75 87
85 3
90 0
CANDELA TABLE
Degrees
Vertical Candela
0 2499
5 2528
15 2727
25 2670
35 1933
45 780
55 83
65 11
75 3
85 0
90 0
LUMINANCE
Average
Candela
Degrees
Average
0°
Luminance
45 2844
55 400
65 205
75 113
85 0
LUMINANCE
Average
Candela
Degrees
Average
0°
Luminance
45 1337
55 149
65 67
75 0
85 0
LUMINANCE
Average
Candela
Degrees
Average
0°
Luminance
45 15933
55 13046
65 8819
75 3657
85 323
LUMINANCE
Average
Candela
Degrees
Average
0°
Luminance
45 11948
55 1569
65 274
75 113
85 0
PHOTOMETRY
LDRT4B EU4B 4LBW 4LBM 4LBN
01/24/2019
(1) Custom Skylight by A.I.A.
Industries
4'-6" wide x 11'-1" long
2:12 pitch
see specifications attached
(2) Vellux Skylights
E-Class Vented Deck Mount
Model EVMS 4646
46 1/2" x 46 1/2"
see specifications attached
15_323WHALLAM_SPEC SHEET_ROOF PLAN
01/24/2019
08630 - 1
A.I.A. Industries, Inc. SECTION 08630
290 E. 56th Avenue
Denver, CO 80216
303.296.9696
Fx 303.296.2146
GENERAL SPECIFICATION DATA
METAL FRAMED SKYLIGHTS
PART 1 - GENERAL
1.01 SCOPE
A. Design, and fabrication of entire skylight system to include all extruded aluminum framing, anchors,
and flashing metals.
B. Glazing and glazing materials including gaskets, sealants, setting blocks, backer rods, and related
materials.
C. Finish on metal components.
D. Installation of the metal framed skylight system.
1.02 RELATED WORK
A. Section 05120: Structural Steel.
B. Section 05500: Metal Fabrications.
C. Section 07620: Sheet Metal Flashing and Trim.
D. Section 08800: Glazing.
1.03 REFERENCES
A. American Architectural Manufacturers Association (AAMA).
B. American Society for Testing and Materials (ASTM).
C. Flat Glass Manufacturers Association (FGMA).
1.04 PERFORMANCE REQUIREMENTS
A. Skylight system shall be designed to support loads as specified by local building codes for the
location of the project, described and/or specified herein as:
1. Positive Live Loads:
a. Snow Load..................PSF
b. Wind Load..................PSF
c. Dead Load....................lbs.
2 Negative Live Loads:
a. Wind Load..................PSF
3. Load Combinations:
a. Snow Load + Dead Load
b. Wind Load + Dead Load
4. The maximum allowable deflection of any framing member normal to the plane of the glass
15_323WHALLAM_SPEC SHEET_SKYLIGHT - AIA
01/24/2019
METAL FRAMED SKYLIGHTS SECTION 08630
08630 - 2
shall not exceed L/175. Spans of 20' - 0" or greater shall not exceed a maximum allowable
deflection of L/240.
B. Manufacturer's system shall meet or exceed all performance standards as outlined by the following
tests:
1. ASTM E283 (air infiltration)
2. ASTM E331 & AAMA 501(water penetration)
3. AAMA 1502.7 (condensation resistance)
C. Thermal movement of system caused by ambient temperature ranges of + 70 degrees F without
causing buckling, undue stress on structural elements, stresses on glass, failure of seals,
performance reduction or other detrimental effects.
1.05 SUBMITTALS
A. Shop drawings as required to fully describe the skylight system shall be submitted and approved by
the architect prior to starting any fabrication.
B. Finished aluminum samples (color charts or range samples), and glazing samples shall be submitted
and approved by the architect prior to starting any fabrication.
C. Submit manufacturer's written warranty as outlined in paragraph 1.07 of this specification.
1.06 QUALITY ASSURANCE
A. The skylight manufacturer shall be responsible for the design, fabrication, and installation of the
skylight assembly.
B. Substitute manufacturer's will be considered only when all of the following conditions have been
satisfied:
1. Alternate manufacturer's must be approved by architect to bid not less than twenty (20)
days prior to bid date.
2. Detailed drawings for alternate skylight system are submitted to architect for review.
3. Structural calculations, showing sizes of framing members and loads applied to the support
structure, based on the design loads of this specification are submitted for review.
4. Prospective manufacturer's must furnish evidence of their ability to perform, including a list of
projects of similar design and complexity within the last ten (10) years.
5. Prospective skylight systems must be manufactured by a firm with a minimum of ten (10)
years experience in the fabrication and installation of custom aluminum framed skylights.
1.07 WARRANTY
A. The skylight system shall be warranted for a period of ( ____ ) year(s) after substantial completion
against defects in materials and workmanship.
B. All glazing shall be warranted pursuant to the glazing manufacturer's standard warranties. Glass
breakage is not covered by these warranties.
C. All aluminum finishes are warranted pursuant to the suppliers standard warranty.
D. The structural sealant is warranted for ( ____ ) year(s) pursuant to the sealant manufacturer's
standard warranty of merchantable quality. Warranty shall certify that cured sealant:
1. Shall not become brittle or crack due to weathering or normal expansion and contraction of
adjacent surfaces.
2. Shall not harden nor soften beyond a Shore "A" durometer of 30 points.
3. Shall not change color significantly when used with compatible backup materials.
4. Shall not bleed significantly.
01/24/2019
METAL FRAMED SKYLIGHTS SECTION 08630
08630 - 3
PART 2 - PRODUCTS
2.01 MANUFACTURER
A. Metal framed skylights shall be manufactured by: A.I.A. Industries, Inc.
290 East 56th Avenue
Denver, Colorado, 80216
303.296-9696 Fax 303.296.2146
2.02 MATERIALS
A. Framing members:
1. Extruded aluminum shall have minimum mechanical properties equal to or greater than
6063-T5 alloy and temper.
2. Snap on covers and miscellaneous non-structural trim shall be the minimum thickness
recommended by the manufacturer.
B. Flashing:
1. All formed aluminum sheet shall be the required alloy and temper to make compatible with the
specified finish, with a minimum thickness of .040".
C. Fasteners and Anchors:
1. Exposed fasteners shall be stainless steel or zinc coated, unless otherwise noted.
D. Glazing Material: Thickness to be determined by codes, glazing area loading conditions and
manufacturers recommendations.
1. Insulating glass unit consisting of 1/4 inch tempered (specify color and/or coating) exterior
lite; 1/2 inch air space; and (___) inch clear (tempered) (laminated) (annealed interior lite with
a .030 PVB interlayer) (heat strengthened interior lite with a (.030) (.060) PVB interlayer.)
2. Laminated glass unit consisting of: (___) inch (specify color and/or coating) laminated, heat
strengthened glass with a (.030) (.060) PVB interlayer.
3. Insulating acrylic unit consisting of (___) inch (clear, bronze, or gray) exterior lite; 1/2 inch air
space; (___) inch (clear or white) interior lite. The spacer bar shall allow for independent
expansion and contraction of the interior and exterior lites.
4. (___) inch (polycarbonate) (acrylic) (double / triple wall) unit (specify color).
E. Glazing Gaskets:
1. Extruded black E.P.D.M. meeting or exceeding the following:
a. Hardness (Shore A) = 50 + durometer
b. Tensile strenght = 2000 psi
c. Elongation = 50%
F. Sealants:
1. Selection of sealants shall be the responsiblity of the skylight manufacturer.
2. All surfaces shall be cleaned and primed within the sealant manufacturers guidelines.
G. Finishes:
1. All exposed aluminum shall receive one or more of the following finishes (architect to select):
a. Clear or Dark Bronze anodized.
b. Powder Coated, (standard color).
c. Acrylic enamel (custom color).
d. Other: ________________________
01/24/2019
METAL FRAMED SKYLIGHTS SECTION 08630
08630 - 4
2.03 FABRICATION
A. Skylights shall be shop fabricated to the greatest extent possible.
B. All welding shall be done by inert gas process, exposed welds to be ground and sanded smooth.
C. System to be fabricated using integral condensate gutters and weep systems allowing any water
penetration to drain to the outside.
PART 3 - EXECUTION
3.01 INSTALLATION
A. Metal framed skylights shall be installed by: A.I.A. Industries, Inc.
290 East 56th Avenue
Denver, Colorado, 80216
303.296.9696 Fax 303.296.2146
B. A.I.A. Industries may authorize a third party to install the skylight.
C. Prior to installation, installer, shall notify the general contractor of obvious deficiencies or dimensional
errors in the support system and/or construction. No installation work shall proceed until all errors
and deviations are corrected. Written authorization may be given to proceed with the as-built
construction along with any price corrections.
D. ADJACENT AND SUPPORT CONSTRUCTION MUST SUPPORT FORCE IMPOSED BY SKYLIGHT
SYSTEM.
E. Skylight materials shall be installed in strict accordance with manufacturer's installation instructions
and drawings.
F. Install skylights plumb, level and true to line, without warp or rack of frames or panels and anchor
securely in place in accordance with approved shop drawings.
G. Contact areas between dissimilar metals shall be isolated with a protective coating or plastic strip to
prevent electrolytic corrosion.
H. Upon completion of installation, installer shall remove all labels, part number markings and excess
sealants from skylight components. Weep system shall be clear of any and all obstructions.
3.02 FINAL CLEANING
A. Final cleaning and physical protection of all installed materials shall be the responsibility of the
general contractor.
END OF SECTION
01/24/2019
LABORATORY, FIELD TESTING AND ADVISORY SERVICES FOR THE BUILDING ENVELOPE
30 YEARS STRONG, UL AND CLEB SERVING CUSTOMERS ACROSS NORTH AMERICA
CHICAGO
US Headquarters
750 Anthony Trail
Northbrook, IL 60062
chicago@cleb.com
MONTREAL
Canada Headquarters
1320 Lionel-Boulet Blvd
Varennes, QC J3X 1P7
montreal@cleb.com
QUEBEC
420 Charest East Blvd
Suite 300
Quebec, QC G1K 8M4
quebec@cleb.com
OTTAWA
29 Capital Drive
Suite 200
Ottawa, ON K2G 0E7
ottawa@cleb.com
TRURO
64 Inglis Place
Suite 203
Truro, NS B2N 4B4
truro@cleb.com
NEW YORK
747 Third Avenue
2nd Floor
New York, NY 10017
newyork@cleb.com
T: 855.353.2532 W: ul.com/buildingenvelope
SIMULATION TEST REPORT FOR U-FACTOR/SHGC/VT/CR
REPORT No: 4788305776
CLIENT:
AiA Industries
290 E. 56th Avenue
Denver, CO 80216
PRODUCT TYPE:
Single Slope Skylight
Glazing U-factor SHGC VT CR
Triple-Pane. With
100% Air-Filled
Cavity
0.38 Btu/hr-ft2-ºF 0.20 0.36 63
Triple-Pane. With
90% Argon/10%
Air-Filled Cavity
0.35 Btu/hr-ft2-ºF 0.20 0.36 64
*Dual-Pane. With
100% Air-Filled
Cavity
0.52 Btu/hr-ft2-ºF 0.23 0.40 60
*Dual-Pane. With
90% Argon/10%
Air-Filled Cavity
0.47 Btu/hr-ft2-ºF 0.23 0.40 64
* Note: 2nd revision. Two rows added to include dual-pane IG options.
Simulation Test Date: 02/05/2018, 03/26/2018
Report Date: 02/10/2018
Report Revision 1: 02/23/2018
Report Revision 2: 03/27/2018
01/24/2019
AiA Industries
Report Date: 02/10/2018 Page 2
Revision 2 Date: 03/27/2018
1.0 Summary of Results Issued To: AiA Industries
290 E. 56th Avenue
Denver, CO 80216
2.0 Test Laboratory: UL LLC
Northbrook, Illinois 60062
3.0 Project Summary:
3.1 Product Type: Skylight
3.2 Series/Model: Single Slope
3.3 Compliance Statements:
Results obtained are simulated values for U-factor, Solar Heat Gain Coefficient (SHGC), Visible
Transmittance (VT), and Condensation Resistance (CR) and were secured by using the
designated NFRC test method(s) in full compliance. Test specimen description and results are
reported herein.
This report may not be reproduced, except in full, without the written approval of UL, LLC.
3.4 Simulation Date: 02/05/2018, 03/26/2018
3.5 NFRC Test Methods:
ANSI/NFRC 100-2017, Procedure for Determining Fenestration Product U-factors
ANSI/NFRC 200-2017, Procedure for Determining Fenestration Product Solar Heat Gain
Coefficient and Visible Transmittance at Normal Incidence
NFRC 500-2017 Procedure for Determining Fenestration Product Condensation
Resistance Value
3.6 Software Used:
Berkeley Lab WINDOW 7.4
THERM 7.4
3.7 Test Source and Retention:
The product line simulated were based on drawings submitted by the client. Simulation report,
data, and drawings will be retained by UL LLC for a minimum of five years from the test
completion date.
4.0 Specimen Description:
Specimen Specimen Description
NFRC Model
Sizes
1200mm x 1200mm (47.2" x 47.2")
01/24/2019
AiA Industries
Report Date: 02/10/2018 Page 3
Revision 2 Date: 03/27/2018
Specimen Description (Continued):
Frame The frame was comprised of aluminum-alloy members exterior and interior members
separated extruded polystyrene insulation. The wood curb was four (4) 2x4
hardwood members combined.
Glazing Systems 1-7/8" overall triple-glazed system:
Exterior lite was 6mm PPG Solarban 100 LowE (surface #2)
*Air gap was 0.500" with 100% Air or 90%/10% Argon-Air Mix
Center lite was 6mm Clear
Air gap was 0.500" with 100% Air or 90%/10% Argon-Air Mix
Interior lite was clear Guardian laminate comprised of 4mm glass/0.060" PVB
interlayer/4mm glass.
*1-1/8" overall dual-glazed system:
Exterior lite was 6mm PPG Solarban 100 LowE (surface #2)
*Air gap was 0.500" with 100% Air or 90%/10% Argon-Air Mix
Center lite was 6mm Clear
Interior lite was clear Guardian laminate comprised of 4mm glass/0.060" PVB
interlayer/4mm glass.
Spacer System Steel spacer with a secondary seal of hot-melt butyl.
* Revised Items in this report
5.0 Test Results:
Glazing U-factor SHGC VT CR
Triple-Pane. With
100% Air-Filled
Cavity
0.38 Btu/hr-ft2-ºF 0.20 0.36 63
Triple-Pane. With
90% Argon/10%
Air-Filled Cavity
0.35 Btu/hr-ft2-ºF 0.20 0.36 64
*Dual-Pane. With
100% Air-Filled
Cavity
0.52 Btu/hr-ft2-ºF 0.23 0.40 60
*Dual-Pane. With
90% Argon/10%
Air-Filled Cavity
0.47 Btu/hr-ft2-ºF 0.23 0.40 64
* Note: 2nd revision. Two rows added to include dual-pane IG options.
6.0 Modeling Assumptions and Technical Notes
- Skylight results were calculated at a slope of 20° above horizontal as required per ANSI/NFRC
100.
01/24/2019
AiA Industries
Report Date: 02/10/2018 Page 4
Revision 2 Date: 03/27/2018
Appendix A: Assembly Drawings of Single Slope Skylight
Appendix B: Revision Log
For UL LLC:
Dennis Anderson
NFRC Certified Simulator
Program/Project Manager
01/24/2019
AiA Industries
Report Date: 02/10/2018 Page 5
Revision 2 Date: 03/27/2018
Appendix A: Assembly Drawings of Single Slope Skylight
01/24/2019
AiA Industries
Report Date: 02/10/2018 Page 6
Revision 2 Date: 03/27/2018
01/24/2019
AiA Industries
Report Date: 02/10/2018 Page 7
Revision 2 Date: 03/27/2018
01/24/2019
AiA Industries
Report Date: 02/10/2018 Page 8
Revision 2 Date: 03/27/2018
01/24/2019
AiA Industries
Report Date: 02/10/2018 Page 9
Revision 2 Date: 03/27/2018
Appendix B
Revision Records
02/23/2018: Report revised to add an Argon Gas option to the glazing cavity.
Because of this revision, it was noticed that the CR for the initial report had a type
error and was corrected to read 63. See asterisk items.
03/27/2018: Report revised to add dual-glazed options to skylight. Description and
results tables updated.
01/24/2019
OPERABLE UNIT SKYLIGHTS 06_2018 08620 deck mounts
1
SECTION 08620
E-CLASS VENTED DECK MOUNT SkyWindow®
PART 1-GENERAL
1.1 SUMMARY
A. This section includes the following:
1. Model EV: E-Class deck mount manual vent glass glazed unit skylights.
2. Model EVMS: E-Class deck mount solar power motorized vent glass glazed unit skylights.
1.2 REFERENCE STANDARDS
A. ASTM E 283 – Standard Test Method for Determining Rate of Air Leakage
Through Exterior Windows, Curtain Walls, and Doors Under Specific
Pressure Differences Across the specimen.
B. ASTM E 330 – Standard Test Method for Structural Performance of Exterior
Windows, and Doors Skylights and Curtain Walls by Uniform Static Air
Pressure Difference.
C. ASTM E 331 – Standard Test Method for Water Penetration of Exterior
Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure
Difference.
D. North American Fenestration Standard (NAFS) AAMA\WDMA\CSA\101\I.S.2\A440.
E. National Fenestration Rating Council, NFRC 100, Procedure for Determining
Fenestration Product U-factors.
F. National Fenestration Rating Council, NFRC 200, Procedure for Determining
Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance
at Normal Incidence.
1.3 PERFORMANCE REQUIREMENTS
A. General: Provide unit skylights capable of withstanding loads as defined by the local codes having jurisdiction
where units are to be installed without failure.
B. Units shall be tested to compliance with AAMA\WDMA\CSA\101\I.S.2\A440 as required by the International
Building Code.
C. Provide units tested to AAMA\WDMA\CSA\101\I.S.2\A440 with the following rating:
SKG-PG40 1295 x 1295 (51 x 51).
D. Water Infiltration: No uncontrolled leakage when tested in accordance with ASTM E331 at a test pressure of 15 psf.
E. Air Infiltration: Air leakage shall not exceed 0.01 cfm per square foot of surface area when tested in accordance with
ASTM E283 at differential static pressure of 1.57 psf.
F. Thermal Performance: Provide full system NFRC certified performance as follows:
1. eMAX3: U-factor = 0.49, SHGC = 0.25, VT = 58%
2. eMAX3 laminated: U-factor = 0.48, SHGC = 0.25, VT = 57%
3. Triple Glaze 30-30: U-factor = 0.33, SHGC = 0.22, VT = 42%
15_323WHALLAM_SPEC SHEET_SKYLIGHT - VELLUX
01/24/2019
OPERABLE UNIT SKYLIGHTS 06_2018 08620 deck mounts
2
1.4 SUBMITTALS
A. Product Data Sheet: For each type of skylight specified, include details of construction and installation, relative to
applicable roofing materials.
B. Samples for Selection: Manufacturer’s color charts showing a full range of colors available for each type of skylight
glazing and aluminum finish.
1.5 WARRANTY
A. General: Warranties specified in this section shall not deprive the Owner of other rights the Owner may have under
other provisions of the Contract Documents and shall be in addition to and run concurrent with other warranties
made by the Contractor under requirements of the Contract Documents.
B. Skylight Warranty: Provide written warranty signed by manufacturer, agreeing to repair or replace work that
exhibits defects in materials or workmanship and guaranteeing weather-tight and leak-free performance. “Defects”
is defined as uncontrolled leakage of water and abnormal aging or deterioration.
1. Warranty Period: 10 years from original date of purchase.
C. Glass Warranty: Provide written warranty signed by manufacturer agreeing to repair or replace work that has or
develops defects in the insulating glass. “Defects” is defined as seal failure.
1. Warranty Period for Insulating Glass: 20 years from date of original purchase.
D. Finish Warranty: Provide written warranty signed by manufacturer agreeing to repair or replace work with finish
defects. “Defects” is defined as peeling, chipping, chalking, fading, abnormal aging or deterioration, and failure to
perform as required.
1. Warranty Period for Powder Coat Finish: 10 years from date of Substantial Completion.
PART 2- PRODUCTS
2.1 MANUFACTURERS
A. Manufacturers: Subject to compliance with requirements, provide products by Wasco Skylights / part of the Velux
Group, Wells, ME 04090, (800-388-0293).
B. Substitutions: Not Permitted.
2.2 MATERIALS
A. Curb Frame: Bright white high-performance ridge PVC with Bronze cap stock, coextruded with soft vinyl flashing.
Provide integral condensation gutter system with corners fully welded for waterproof quality.
B. Retainer Frame: Extruded aluminum alloy 6063-T5 (min). ASTM B 221 (ASTM B 221 M) with minimum
effective thickness of 0.060 inch (1.5 mm). The aluminum retaining frame is mitered and secured using an
aluminum staking corner key. Quaker Bronze powder coat finish.
C. Thermal Break: Fabricate skylight units with thermal chambered PVC frame.
D. Fasteners: Non-magnetic stainless steel or other non-corrosive metal as recommended by manufacturer.
E. Insulating Glass:
1. eMAX3: Clear tempered Low-E outer, argon filled airspace, clear tempered inner pane.
2. eMAX3 laminated: Clear tempered Low-E outer, argon filled airspace, heat strengthened laminated inner
pane.
3. Triple Glazed 30- 30: Clear tempered Low-E outer, argon airspace, clear tempered middle pane, argon
airspace, clear tempered Low-E inner pane.
F. Lumira Aerogel: 25 mm Multi-wall flat cellular polycarbonate panel filled with Lumira™ aerogel insulation
material.
01/24/2019
OPERABLE UNIT SKYLIGHTS 06_2018 08620 deck mounts
3
2.3 OPERATORS
A. Model EV: WLS Manual Operator standard with hand crank or eye hook for pole operation.
a. Options:
i. Skylight Pole
ii. WLS Motor Kit: includes wall mount switch and rain sensor. Motor mounts over existing manual
operator.
iii. WLS Remote Control
B. Model EVMS: Solar Powered Electric Operator, includes one remote control per unit.
2.4 FABRICATION
A. Framing Components: As follows:
1. Factory fit and assemble components.
1. Fabricate components that, when assembled, will have accurately fitted joints with ends coped or mitered.
2. Fabricate components to accommodate expansion, contraction, and field adjustment, and to provide for
minimum clearance and shimming at skylight perimeter.
3. Fit and secure PVC frame joints by thermal welding.
4. Fit and secure aluminum retainer joints with corner keys.
5. No site fabrication required.
2.5 ALUMINUM FINISHES (EDIT AS REQUIRED)
A. General: Comply with NAAMM “Metal Finishes Manual” recommendations for application and designations of
finishes.
B. Finish designations prefixed by AA conform to the system for designations of aluminum finishes established by the
Aluminum Association.
1. Powder Coat High-Performance Architectural Coating: comply with AAMA 2604. Color:______________
(contact manufacturer for color options)
2. Copper Cladding
PART 3- EXECUTION
3.1 EXAMINATION
A. Examine substrates and conditions, with installer present, for compliance with requirements for installation
tolerances and other conditions affecting skylight performance.
1. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. General: Comply with manufacturer’s written instructions for protecting, handling, and installing skylight
components.
3.3 CLEANING AND PROTECTION
A. Clean exposed metal and glass surfaces according to manufacturer’s instructions. Touch up damaged metal
coatings.
B. Protect skylight surfaces from ongoing construction.
C. Final cleaning by others.
END OF SECTION
01/24/2019
VMS (VELUX Modular Skylight)
Thermal and Other Testing
Technical Data
July 2016
Glazing Type Glazing Description Module Type
U-Factor
arg/xenon SHGC VT
clr/wht
Low Energy Dual Pane at 20° above horiz.
8mm Temp exterior with Lami interior Fixed (HFC) 0.34/0.25 0.46 0.64/0.46
Low Energy Dual Pane at vertical
8mm Temp exterior with Lami interior Fixed (HFC) 0.28/0.23 0.46 0.64/0.46
Low Energy with HanGlas Dual Pane at 20°
8mm Temp exterior with Lami interior Fixed (HFC) 0.33/0.24 0.25 0.46/0.33
Low Energy with HanGlas Dual Pane at vert.
8mm Temp exterior with Lami interior Fixed (HFC) 0.27/0.22 0.24 0.46/0.33
Super Low Energy Triple Pane at 20°
8mm Temp, 8mm center and Lami interior Fixed (HFC) 0.21/ - 0.36 0.55/0.40
Super Low Energy Triple Pane at vert.
8mm Temp, 8mm center and Lami interior Fixed (HFC) 0.16/ - 0.36 0.56/0.40
Low Energy Dual Pane at 20° above horiz.
8mm Temp exterior with Lami interior Venting (HVC) 0.35/0.25 0.46 0.64/0.46
Low Energy Dual Pane at vertical
8mm Temp exterior with Lami interior Venting (HVC) 0.29/0.24 0.46 0.64/0.46
Low Energy with HanGlas Dual Pane at 20°
8mm Temp exterior with Lami interior Venting (HVC) 0.34/0.24 0.24 0.46/0.33
Low Energy with HanGlas Dual Pane at vert.
8mm Temp exterior with Lami interior Venting (HVC) 0.28/0.24 0.24 0.46/0.33
Super Low Energy Triple Pane at 20°
8mm Temp, 8mm center and Lami interior Venting (HVC) 0.22/ - 0.36 0.55/0.40
Super Low Energy Triple Pane at vert.
8mm Temp, 8mm center and Lami interior Venting (HVC) 0.17/ - 0.36 0.56/0.40
Tested in accordance with NFRC requirements per standards NFRC 100-2010, NFRC 200-2010 and NFRC 500-2010
37
28
Passed
40
34
HFC Module
Type 11 Glazing
1m x 2.4m
1200 lb-ft
HFC Module
Type 11T Glazing
1m x 3m
1200 lb-ft
400 lbs
500° C
410° C
7.0
Class CC1
3,925.7 lbs.
1,260 lbs.
3,243.8 lbs.
1,545 lbs.
HFC/HVC Module
Type 16T Glazing
1m x 1.8m
Acoustics Testing per ASTM E 90 and ASTM E 413 STC (Interior Noise)
Acoustics Testing per ASTM E 90 and ASTM E 1332 OITC (Exterior Noise)
Linear Rate of Burn ASTM D 635
Average Maximum
Allowable Load
Bracket Loads
(Ridgelight,
Longlight and
lower Northlight)
Loaded In-Line
Loaded at 45° angle Average Maximum
Allowable Load
OSHA Fall Resistance test where 200 lb weight dropped from 6 ft
height with no damage to panes to comply with OSHA 29CFR
1910.23(e)(8)
OSHA Fall Resistance
Self Ignition Temperature ASTM D 1929
Flash Ignition Temperature ASTM D 1929
Average Smoke Density Rating ASTM D 2843
OSHA Fall Resistance test where 200 lb weight was dropped from 6
ft height with no damage to comply with OSHA 29CFR 1910.23(e)(8),
and CalOSHA Fall Resistance test where 400 lb weight was resisted
for 60 seconds per CCR Title 8, Section 3212
OSHA Fall Resistance
CalOSHA Fall Resistance
VMS Product Performance - Other Test Results
Acoustics Testing per ASTM E 90 and ASTM E 413 STC (Interior Noise)
Acoustics Testing per ASTM E 90 and ASTM E 1332
Burning Brand Test ASTM E 108
OITC (Exterior Noise)
Class B Burning Brand
VMS Modules - Thermal Performance Test Results
HFC/HVC Module
Type 11 Glazing
1m x 2.4m
Pultruded
Composite
VMS Frame
Type 10
Type 11
Type 16
Type 10
Type 11
Type 16
01/24/2019