Loading...
HomeMy WebLinkAboutFile Documents.355 S Monarch St.0118.2018.ACBKDATE Date: Scale: Drawn by: REVISIONS Z4A WWW.ZONE4ARCHITECTS.COM PERMITZ4A 11.08.18 Y:\Shared\Data\_Z4 Projects\1831 Limelight Offices\Model\LIMELIGHT OFFICES_v21.plnBY A200 1/25/2019Plotted On: 1/25/2019 AS NOTED FAR ZONE 4 ARCHITECTS IS NOT LIABLE OR RESPONSIBLE AT ANY TIME FOR ANY CHANGES TO THESE DRAWINGS OR SPECIFICATIONS WITHOUT PRIOR WRITTEN AUTHORIZATION.c 2015 ZONE 4 ARCHITECTS, LLC. THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ZONE 4 ARCHITECTS LLC. NO PART OF THIS INFORMATION MAY BE USED OR COPIED WITHOUT THE PRIOR WRITTEN PERMISSION OF ZONE 4 ARCHITECTS LLC. ZONE 4 ARCHITECTS LLC. SHALL RETAIN ALL COMMON LAW STATUTORY AND ALL OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. ALL RIGHTS RESERVEDL I M E L I G H T O F F I C E SLIMELIGHT HOTEL355 S. MONARCHASPEN, COLORADOEXISTING SKI & BOOT STORAGE AREA: PROPOSED OFFICE SPACE AREA: PROPOSED STORAGE AREA: EXISTING OCCUPANCY= PROPOSED OCCUPANCY= PER 2015 IBC 1006.2.1, S2 AND B OCCUPANCY COMMON PATH OF EGRESS W/ SPRINKLER SYSTEM CANNOT EXCEED 100ft. S2 OCCUPANT LOAD FACTOR= B OCCUPANCT LOAD FACTOR= EXISTING S.F. = 724.2 S: 378.62 s.f./300 s.f.= B: 340.75 s.f./100 s.f.= 724.2 s.f. 340.75 s.f. 378.62 s.f. S2 W/ 29 PEOPLE MAX. OCCUPANCY LOAD B W/ 49 PEOPLE MAX. OCCUPANCY LOAD PROPOSED OFFICE COMMON PATH OF EGRESS IS 32'-7 1/2" PROPOSED STORAGE COMMON PATH OF EGRESS IS 57'-7 1/2" 300 GROSS 100 GROSS 1.26 OCCUPANT LOAD 3.40 OCCUPANT LOAD (< CODE MAX.) CODE STUDY CONCLUSION ONE SINGLE EXIT IS PERMITTED PER 2015 IBC 1006.3.2. 021'-2 1/2"2'-0"2'-0"11'-4"1'-2 1/2"3'-8 1/2"2'-0"11'-4"15'-7"2'-0"23'-3" 2'-3" 340.75 sq ft 378.62 sq ft 43'-4"2'-0"2'-0"2'-0"11'-4"724.2 sq ft 02 INSUBSTANTIAL AMENDMENTZ4A 09.18.18 SUPPLEMENTAL INFORMATIONZ4A 01.25.19 SCALE: 1/4" = 1'-0"01 PROPOSED LOWER LEVEL AREA PLAN SCALE: 1/4" = 1'-0"02 EXISTING LOWER LEVEL AREA PLAN 1. EXISTING BUILDING HAS FIRE SUPPRESSION SYSTEM INSTALLED AND IS TO REMAIN. G.F.A. NOTES: 01/31/2019 bonniem DATE Date: Scale: Drawn by: REVISIONS Z4A WWW.ZONE4ARCHITECTS.COM PERMITZ4A 11.08.18 Y:\Shared\Data\_Z4 Projects\1831 Limelight Offices\Model\LIMELIGHT OFFICES_v21.plnBY A301 1/25/2019Plotted On: 1/25/2019 AS NOTED LOWER LEVEL PLAN ZONE 4 ARCHITECTS IS NOT LIABLE OR RESPONSIBLE AT ANY TIME FOR ANY CHANGES TO THESE DRAWINGS OR SPECIFICATIONS WITHOUT PRIOR WRITTEN AUTHORIZATION.c 2015 ZONE 4 ARCHITECTS, LLC. THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ZONE 4 ARCHITECTS LLC. NO PART OF THIS INFORMATION MAY BE USED OR COPIED WITHOUT THE PRIOR WRITTEN PERMISSION OF ZONE 4 ARCHITECTS LLC. ZONE 4 ARCHITECTS LLC. SHALL RETAIN ALL COMMON LAW STATUTORY AND ALL OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. ALL RIGHTS RESERVEDL I M E L I G H T O F F I C E SLIMELIGHT HOTEL355 S. MONARCHASPEN, COLORADO001A A A B B 1 1 2 2 01 02 5'-0"3'-6"12'-0"V.I.F.47'-10" V.I.F.3'-4"R.O.8'-5 1/2"4'-0" MIN.1'-0"MIN.EL. 88'-1 1/2" V.I.F. EL. 88'-1 1/2" V.I.F. ELEVATOR STAIR STORAGE OFFICE SPACE T.O. CONC. STORAGE T.O. CONC. PROPOSED WALL SEPARATING EXISTING STORAGE FROM OFFICE EXISTING PARKING GARAGE NOT IN SCOPE (EXISTING)FIRE RESISTIVE ASSEMBLY PER 2015 IBC 707.3.9 NOTE: NO CHANGE TO EXISTING NET LEASABLE/NET LIVABLE AREAS WITH PROPOSED OCCUPANCY CHANGE. UP PROPOSED OFFICE SPACE EXISTING PARKING SPACES W-1 CLEAR FLOOR SPACE PER ANSI 404.2.3.1 W-1W-1 LEGEND NEW WALL EXISTING WALL EXISTING BUILDING OUTSIDE OF SCOPE 02 INSUBSTANTIAL AMENDMENTZ4A 09.18.18 SUPPLEMENTAL INFORMATIONZ4A 01.25.19 SCALE: 1/4" = 1'-0"01 PROPOSED FLOOR PLAN 1. SITE ELEVATION 7915.82' = ARCHITECTURAL ENTRY LEVEL T.O. SLAB FLOOR ELEVATION 100'-0". 2. REFER TO STRUCTURAL DOCUMENTS FOR ALL STRUCTURAL COLUMNS AND BEAMS. 3. REFER TO INT. FINISH FLOOR PLANS FOR FINISH FLOOR MATERIALS. 4. STAIRWAY AND HANDRAIL PER 2015 IBC 1011.11. GUARDRAILS PER 2015 IBC 1011.13. 5. ILLUMINATE STAIRS PER 1008.1. MINIMUM OF 50% OF PERMANENTLY INSTALLED FIXTURES TO CONTAIN HIGH EFFICACY LAMPS PER IEEC 404.1. 6. ALL MATERIAL INSULATION VALUES TO MEET 2015 IECC MIN. STANDARDS FOR CLIMATE ZONE 7. REFER TO TYPICAL ASSEMBLIES. 8. GARAGE SEPARATION AND OPENINGS PER 2015 IRC R302.5.1 AND R302.6. 9. FINAL HOSE BIB (H.B.) LOCATIONS TO BE FIELD VERIFIED WITH OWNER. 10. "INTERIORS" OR "INT." REFERS TO INTERIOR DESIGNER. (TYPICAL) 10. REFER TO RCPs FOR CARBON MONOXIDE / SMOKE DETECTOR LOCATIONS. 11. REFER TO INTERIOR DOCUMENTS FOR ALL FINISH MATERIAL SPECIFICATIONS, MILLWORK DESIGN, ETC. 12. EXISTING STRUCTURE BEYOND LOWER LEVEL OFFICE SPACE NOT IN SCOPE OF ___WORK. PLAN NOTES 01/31/2019 bonniem DATE Date: Scale: Drawn by: REVISIONS Z4A WWW.ZONE4ARCHITECTS.COM PERMITZ4A 11.08.18 Y:\Shared\Data\_Z4 Projects\1831 Limelight Offices\Model\LIMELIGHT OFFICES_v21.plnBY A901 1/25/2019Plotted On: 1/25/2019 AS NOTEDREFLECTED CEILING + LIGHTING PLAN ZONE 4 ARCHITECTS IS NOT LIABLE OR RESPONSIBLE AT ANY TIME FOR ANY CHANGES TO THESE DRAWINGS OR SPECIFICATIONS WITHOUT PRIOR WRITTEN AUTHORIZATION.c 2015 ZONE 4 ARCHITECTS, LLC. THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ZONE 4 ARCHITECTS LLC. NO PART OF THIS INFORMATION MAY BE USED OR COPIED WITHOUT THE PRIOR WRITTEN PERMISSION OF ZONE 4 ARCHITECTS LLC. ZONE 4 ARCHITECTS LLC. SHALL RETAIN ALL COMMON LAW STATUTORY AND ALL OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. ALL RIGHTS RESERVEDL I M E L I G H T O F F I C E SLIMELIGHT HOTEL355 S. MONARCHASPEN, COLORADOA A B B 1 1 2 2 02 EL. EXISTING V.I.F. EL. EXISTING V.I.F. ELEVATOR STAIR STORAGE OFFICE SPACE GWB CMS NOTE: EXISTING LIGHTS TO REMAIN STORAGE NOTE: EXISTING LIGHTS TO REMAIN GWB S EXISTING PARKING GARAGE NOT IN SCOPE (EXISTING) F1 F1 F1 F1 F1 F1 F1 F1 F1 EXISTING WALL-HUNG MINI- SPLIT AC SYSTEM TO REMAIN. G.C. TO VERIFY LOCATION IN FIELD. EXISTING RETURN AIR GRILLE ON WALL TO REMAIN. G.C. TO VERIFY LOCATION IN FIELD. 01 01 02 INSUBSTANTIAL AMENDMENTZ4A 09.18.18 BLDG COMMENTS 01Z4A 12.11.18 SUPPLEMENTAL INFORMATIONZ4A 01.25.19 SCALE: 1/4" = 1'-0"01 LOWER LEVEL LIGHTING / R.C.P. 1. G.C. TO INSTALL SMOKE ALARMS PER NFPA 72 REQUIREMENTS PER IBC 907.2. G.C. TO COORDINATE FINAL LOCATIONS IN FIELD WITH LIGHTING DESIGN / LAYOUT. 2. G.C. TO INSTALL CARBON MONOXIDE DETECTORS PER A.F.P.D. REQUIREMENTS. G.C. TO COORDINATE FINAL LOCATIONS IN FIELD WITH LIGHTING DESIGN / LAYOUT. 3. REFER TO LIGHTING DESIGN DOCUMENTS FOR LIGHT FIXTURE LOCATIONS AND SPECIFICATIONS. 4. REFER TO INTERIOR DESIGNER'S FINISH SCHEDULE FOR FINAL CEILING FINISH. 5. "INTERIORS" OR "INT." REFERS TO INTERIOR DESIGNER. 6. G.C. TO VERIFY LOCATIONS OF EXISTING FIXTURES IN FIELD PRIOR TO CONSTRUCTION. 7. G.C. TO COORDINATE EXISTING SPRINKLER HEAD LOCATIONS IN FIELD WITH A.F.P.D. IF __REQUIRED. 8. OCCUPANCY CONTROL SENSOR TO BE INSTALLED IN NEW OFFICE SPACE PER IECC __C405.2.1. RCP NOTES 01/31/2019 bonniem