HomeMy WebLinkAboutFile Documents.355 S Monarch St.0118.2018.ACBKDATE
Date:
Scale:
Drawn by:
REVISIONS
Z4A
WWW.ZONE4ARCHITECTS.COM
PERMITZ4A 11.08.18
Y:\Shared\Data\_Z4 Projects\1831 Limelight Offices\Model\LIMELIGHT OFFICES_v21.plnBY
A200
1/25/2019Plotted On:
1/25/2019
AS NOTED
FAR
ZONE 4 ARCHITECTS IS NOT LIABLE OR RESPONSIBLE AT ANY TIME FOR ANY CHANGES TO THESE DRAWINGS OR SPECIFICATIONS WITHOUT PRIOR WRITTEN AUTHORIZATION.c 2015 ZONE 4 ARCHITECTS, LLC. THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ZONE 4 ARCHITECTS LLC. NO PART OF THIS INFORMATION MAY BE USED OR COPIED WITHOUT THE PRIOR WRITTEN PERMISSION OF ZONE 4 ARCHITECTS LLC. ZONE 4 ARCHITECTS LLC. SHALL RETAIN ALL COMMON LAW STATUTORY AND ALL OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. ALL RIGHTS RESERVEDL I M E L I G H T O F F I C E SLIMELIGHT HOTEL355 S. MONARCHASPEN, COLORADOEXISTING SKI & BOOT STORAGE AREA:
PROPOSED OFFICE SPACE AREA:
PROPOSED STORAGE AREA:
EXISTING OCCUPANCY=
PROPOSED OCCUPANCY=
PER 2015 IBC 1006.2.1, S2 AND B
OCCUPANCY COMMON PATH OF EGRESS
W/ SPRINKLER SYSTEM CANNOT EXCEED
100ft.
S2 OCCUPANT LOAD FACTOR=
B OCCUPANCT LOAD FACTOR=
EXISTING S.F. = 724.2
S: 378.62 s.f./300 s.f.=
B: 340.75 s.f./100 s.f.=
724.2 s.f.
340.75 s.f.
378.62 s.f.
S2 W/ 29 PEOPLE MAX. OCCUPANCY LOAD
B W/ 49 PEOPLE MAX. OCCUPANCY LOAD
PROPOSED OFFICE COMMON PATH OF EGRESS IS 32'-7 1/2"
PROPOSED STORAGE COMMON PATH OF EGRESS IS 57'-7 1/2"
300 GROSS
100 GROSS
1.26 OCCUPANT LOAD
3.40 OCCUPANT LOAD (< CODE MAX.)
CODE STUDY
CONCLUSION
ONE SINGLE EXIT IS PERMITTED PER 2015 IBC 1006.3.2.
021'-2 1/2"2'-0"2'-0"11'-4"1'-2 1/2"3'-8 1/2"2'-0"11'-4"15'-7"2'-0"23'-3"
2'-3"
340.75 sq ft 378.62 sq ft
43'-4"2'-0"2'-0"2'-0"11'-4"724.2 sq ft
02
INSUBSTANTIAL
AMENDMENTZ4A 09.18.18
SUPPLEMENTAL
INFORMATIONZ4A 01.25.19
SCALE: 1/4" = 1'-0"01 PROPOSED LOWER LEVEL AREA PLAN
SCALE: 1/4" = 1'-0"02 EXISTING LOWER LEVEL AREA PLAN
1. EXISTING BUILDING HAS FIRE SUPPRESSION SYSTEM INSTALLED AND IS TO REMAIN.
G.F.A. NOTES:
01/31/2019
bonniem
DATE
Date:
Scale:
Drawn by:
REVISIONS
Z4A
WWW.ZONE4ARCHITECTS.COM
PERMITZ4A 11.08.18
Y:\Shared\Data\_Z4 Projects\1831 Limelight Offices\Model\LIMELIGHT OFFICES_v21.plnBY
A301
1/25/2019Plotted On:
1/25/2019
AS NOTED
LOWER LEVEL
PLAN
ZONE 4 ARCHITECTS IS NOT LIABLE OR RESPONSIBLE AT ANY TIME FOR ANY CHANGES TO THESE DRAWINGS OR SPECIFICATIONS WITHOUT PRIOR WRITTEN AUTHORIZATION.c 2015 ZONE 4 ARCHITECTS, LLC. THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ZONE 4 ARCHITECTS LLC. NO PART OF THIS INFORMATION MAY BE USED OR COPIED WITHOUT THE PRIOR WRITTEN PERMISSION OF ZONE 4 ARCHITECTS LLC. ZONE 4 ARCHITECTS LLC. SHALL RETAIN ALL COMMON LAW STATUTORY AND ALL OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. ALL RIGHTS RESERVEDL I M E L I G H T O F F I C E SLIMELIGHT HOTEL355 S. MONARCHASPEN, COLORADO001A
A A
B B
1
1
2
2
01
02
5'-0"3'-6"12'-0"V.I.F.47'-10"
V.I.F.3'-4"R.O.8'-5 1/2"4'-0"
MIN.1'-0"MIN.EL. 88'-1 1/2" V.I.F.
EL. 88'-1 1/2" V.I.F.
ELEVATOR
STAIR
STORAGE
OFFICE SPACE
T.O. CONC.
STORAGE
T.O. CONC.
PROPOSED WALL
SEPARATING EXISTING
STORAGE FROM OFFICE
EXISTING PARKING GARAGE
NOT IN SCOPE
(EXISTING)FIRE RESISTIVE
ASSEMBLY PER 2015 IBC
707.3.9
NOTE:
NO CHANGE TO EXISTING NET
LEASABLE/NET LIVABLE AREAS
WITH PROPOSED OCCUPANCY
CHANGE.
UP
PROPOSED OFFICE SPACE
EXISTING PARKING
SPACES
W-1
CLEAR FLOOR SPACE PER
ANSI 404.2.3.1
W-1W-1
LEGEND
NEW WALL
EXISTING WALL
EXISTING BUILDING
OUTSIDE OF SCOPE
02
INSUBSTANTIAL
AMENDMENTZ4A 09.18.18
SUPPLEMENTAL
INFORMATIONZ4A 01.25.19
SCALE: 1/4" = 1'-0"01 PROPOSED FLOOR PLAN
1. SITE ELEVATION 7915.82' = ARCHITECTURAL ENTRY LEVEL T.O. SLAB FLOOR
ELEVATION 100'-0".
2. REFER TO STRUCTURAL DOCUMENTS FOR ALL STRUCTURAL COLUMNS AND BEAMS.
3. REFER TO INT. FINISH FLOOR PLANS FOR FINISH FLOOR MATERIALS.
4. STAIRWAY AND HANDRAIL PER 2015 IBC 1011.11. GUARDRAILS PER 2015 IBC 1011.13.
5. ILLUMINATE STAIRS PER 1008.1. MINIMUM OF 50% OF PERMANENTLY INSTALLED
FIXTURES TO CONTAIN HIGH EFFICACY LAMPS PER IEEC 404.1.
6. ALL MATERIAL INSULATION VALUES TO MEET 2015 IECC MIN. STANDARDS FOR
CLIMATE ZONE 7. REFER TO TYPICAL ASSEMBLIES.
8. GARAGE SEPARATION AND OPENINGS PER 2015 IRC R302.5.1 AND R302.6.
9. FINAL HOSE BIB (H.B.) LOCATIONS TO BE FIELD VERIFIED WITH OWNER.
10. "INTERIORS" OR "INT." REFERS TO INTERIOR DESIGNER. (TYPICAL)
10. REFER TO RCPs FOR CARBON MONOXIDE / SMOKE DETECTOR LOCATIONS.
11. REFER TO INTERIOR DOCUMENTS FOR ALL FINISH MATERIAL SPECIFICATIONS,
MILLWORK DESIGN, ETC.
12. EXISTING STRUCTURE BEYOND LOWER LEVEL OFFICE SPACE NOT IN SCOPE OF
___WORK.
PLAN NOTES
01/31/2019
bonniem
DATE
Date:
Scale:
Drawn by:
REVISIONS
Z4A
WWW.ZONE4ARCHITECTS.COM
PERMITZ4A 11.08.18
Y:\Shared\Data\_Z4 Projects\1831 Limelight Offices\Model\LIMELIGHT OFFICES_v21.plnBY
A901
1/25/2019Plotted On:
1/25/2019
AS NOTEDREFLECTED
CEILING +
LIGHTING
PLAN
ZONE 4 ARCHITECTS IS NOT LIABLE OR RESPONSIBLE AT ANY TIME FOR ANY CHANGES TO THESE DRAWINGS OR SPECIFICATIONS WITHOUT PRIOR WRITTEN AUTHORIZATION.c 2015 ZONE 4 ARCHITECTS, LLC. THE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTY OF ZONE 4 ARCHITECTS LLC. NO PART OF THIS INFORMATION MAY BE USED OR COPIED WITHOUT THE PRIOR WRITTEN PERMISSION OF ZONE 4 ARCHITECTS LLC. ZONE 4 ARCHITECTS LLC. SHALL RETAIN ALL COMMON LAW STATUTORY AND ALL OTHER RESERVED RIGHTS, INCLUDING COPYRIGHT THERETO. ALL RIGHTS RESERVEDL I M E L I G H T O F F I C E SLIMELIGHT HOTEL355 S. MONARCHASPEN, COLORADOA A
B B
1
1
2
2
02
EL. EXISTING V.I.F.
EL. EXISTING V.I.F.
ELEVATOR
STAIR
STORAGE
OFFICE SPACE
GWB
CMS
NOTE: EXISTING LIGHTS
TO REMAIN
STORAGE
NOTE: EXISTING LIGHTS
TO REMAIN
GWB
S
EXISTING PARKING GARAGE
NOT IN SCOPE
(EXISTING)
F1 F1
F1 F1
F1
F1 F1 F1
F1
EXISTING WALL-HUNG MINI-
SPLIT AC SYSTEM TO REMAIN.
G.C. TO VERIFY LOCATION IN
FIELD.
EXISTING RETURN AIR GRILLE
ON WALL TO REMAIN. G.C. TO
VERIFY LOCATION IN FIELD.
01
01
02
INSUBSTANTIAL
AMENDMENTZ4A 09.18.18
BLDG
COMMENTS 01Z4A 12.11.18
SUPPLEMENTAL
INFORMATIONZ4A 01.25.19
SCALE: 1/4" = 1'-0"01 LOWER LEVEL LIGHTING / R.C.P.
1. G.C. TO INSTALL SMOKE ALARMS PER NFPA 72 REQUIREMENTS PER IBC 907.2. G.C. TO
COORDINATE FINAL LOCATIONS IN FIELD WITH LIGHTING DESIGN / LAYOUT.
2. G.C. TO INSTALL CARBON MONOXIDE DETECTORS PER A.F.P.D. REQUIREMENTS. G.C.
TO COORDINATE FINAL LOCATIONS IN FIELD WITH LIGHTING DESIGN / LAYOUT.
3. REFER TO LIGHTING DESIGN DOCUMENTS FOR LIGHT FIXTURE LOCATIONS AND
SPECIFICATIONS.
4. REFER TO INTERIOR DESIGNER'S FINISH SCHEDULE FOR FINAL CEILING FINISH.
5. "INTERIORS" OR "INT." REFERS TO INTERIOR DESIGNER.
6. G.C. TO VERIFY LOCATIONS OF EXISTING FIXTURES IN FIELD PRIOR TO CONSTRUCTION.
7. G.C. TO COORDINATE EXISTING SPRINKLER HEAD LOCATIONS IN FIELD WITH A.F.P.D. IF
__REQUIRED.
8. OCCUPANCY CONTROL SENSOR TO BE INSTALLED IN NEW OFFICE SPACE PER IECC
__C405.2.1.
RCP NOTES
01/31/2019
bonniem