HomeMy WebLinkAboutFile Documents.395 Thunderbowl Ln.0153.2017 (10).ARBK
The permit processing time is stopped on this review and will not begin again until all issues from all review agencies
are addressed and the corrections are approved for resubmittal. At that time, your resubmittal will re-placed in the
queue with other permits being processed.
Sent via e-mail
To: Josh Rice
josh@woodycreekengineering.com
(970) 429-8297
David Johnston
david@djarchitects.com
(970) 925-3444
From: Hailey Guglielmo
Development Engineer, City of Aspen
Phone 970/429-2751, Fax 970/920-5081
hailey.guglielmo@cityofaspen.com
Date: September 7, 2017
Permit Ben Chase
Coordinator: 429-2763
Re: Permit No. 0153.2017.ARBK, 395 Thunderbowl
These design documents have been reviewed for conformance with the Engineering Design Standards and Urban
Runoff Management Plan as adopted and amended by the City of Aspen. State and Federal regulations are
administered where applicable.
The attached comments must be addressed. Please revise and redraw the plans to clearly respond to the attached
comments. Plan corrections cannot be made on the blueprints (i.e., red-lined). All changes must be made to the
originals prior to making prints. Revised drawings must clearly show code compliance. In addition, please
resubmit this comment letter with your written response to each comment. Your response should indicate
which detail or specification page shows the required information. Responses such as “will comply with
code” are not adequate. Finally, please provide both a physical copy and a digital file of your resubmission.
The comment letter should be a Word document.
If you have any questions specifically regarding the comments below, please feel free to contact me directly. If
you have questions regarding the status of other review agencies' comments, the status of your permit in the
queue, or general permitting questions, please contact your Permit Coordinator. (See above for phone numbers.)
IMPORTANT NOTE:
Engineering plan check is only one part of the often complex process by which projects are reviewed for
approval. These parts are interrelated and are sometimes conflicting. Because we are issuing these first review
round comments prior to the time that all review agencies have completed their work, you are receiving
incomplete comments from the City as a whole. It is ultimately the applicant’s responsibility to respond to the
requirements of ALL review agencies. If you choose to begin updating plans and responding to comments prior
to receiving feedback from ALL review agencies, you assume any and all risks associated with needing to adjust,
update, modify, or otherwise redo your work.
1/16/18
The permit processing time is stopped on this review and will not begin again until all issues from all review agencies
are addressed and the corrections are approved for resubmittal. At that time, your resubmittal will re-placed in the
queue with other permits being processed.
When you have received and addressed ALL items from ALL review agencies, please call 970-920-5090 to
schedule a required appointment for re-submittal with your Permit Coordinator. You will be required to bring a
copy of this letter, along with ALL other staff comment letters, with ALL responses and required documentation.
If all items listed have not been addressed, the resubmittal will be deemed incomplete, and will not be accepted.
Once the standards of the Urban Runoff Management Plan standards and requirements are met, the Development
Engineer can sign off on the requested permit. If you have any questions or concerns about any of the items
shown, please feel free to contact me.
IMPORTANT: The City of Aspen Engineering Department is requiring that all stormwater BMP’s be
inspected throughout the construction process to ensure BMP’s are installed per the approved plans. Please
contact Hailey Guglielmo at (970) 429-2751 48 hrs prior to construction of each stormwater BMP.
Sincerely,
Hailey Guglielmo, EIT
Development Engineer
970-429-2751
1/16/18
Engineering Round1_0153.2017.ARBK_395 Thunderbowl 9-7-2017
Page:[1] 1 COVER SHEET - Cover Sheet C0.0
Author:haileyg
File Name: CIVIL.395 THUNDERBOWL.2017.07.13.pdf
An Excavation and Stabilization
plan was not submitted with the
permit set. Please provide.
CIVIL.395 THUNDERBOWL.2017.07.13.pdf (7)
Page:[7] 8 Thunderbowl 20170620 - C4.0 DETAILS
Author:haileyg
File Name: CIVIL.395 THUNDERBOWL.2017.07.13.pdf
Call out 18" minimum depth of
amended native material, 70%
sand 30% topsoil.
Page:[8] 6 Thunderbowl 20170620 - C5.0 UTILITIES
Author:haileyg
File Name: CIVIL.395 THUNDERBOWL.2017.07.13.pdf
Overlay landscaping plan with
the utility plan. Ensure no
conflicts.
Page:[8] 6 Thunderbowl 20170620 - C5.0 UTILITIES
Author:haileyg
File Name: CIVIL.395 THUNDERBOWL.2017.07.13.pdf
Does this transformer have an
adequate easement? It is not
shown on the survey. How much
of the transformer sits on this
property? If no easement exists,
one needs to be recorded prior
to permit issuance.
Page:[8] 6 Thunderbowl 20170620 - C5.0 UTILITIES
Author:haileyg
File Name: CIVIL.395 THUNDERBOWL.2017.07.13.pdf
Call in utility locates and show
water main line on the plans.
Show the exact tap location.
An Excavation and Stabilization plan was not
submitted with the permit set. Please provide.
3.00 FT
Call out 18" minimum
depth of amended
native material, 70%
sand 30% topsoil.
Overlay landscaping plan with the utility plan. Ensure no conflicts.
Does this transformer
have an adequate
easement? It is not
shown on the survey.
How much of the
transformer sits on this
property? If no
easement exists, one
needs to be recorded
prior to permit
issuance.
Call in utility locates
and show water main
line on the plans.
Show the exact tap
location.
See Shoring Plans and
memo stating feasability of
shoring options
Callout has been added.
Landscape has been shown.
Transformer will be accessed
from subject property only
The utility locates and tap
location are now shown.
1/16/18
The soil nails do not stay within the building
envelope. The PD amendment needs to be
approved before I can sign off on the
permit.
Landscape is not shown on any sheet. I
think a layer is turned off, as information
that was on the last submittal is not shown
on these sheets.
Page:[8] 6 Thunderbowl 20170620 - C5.0 UTILITIES
Author:haileyg
File Name: CIVIL.395 THUNDERBOWL.2017.07.13.pdf
Water service lines shall be as
short as feasible. There is a
water main along Thunderbowl
Ln south of the property which
could be tapped.
Page:[8] 6 Thunderbowl 20170620 - C5.0 UTILITIES
Author:haileyg
File Name: CIVIL.395 THUNDERBOWL.2017.07.13.pdf
Utilities shall be routed around
the raingarden to avoid damage
from additional infiltration.
Page:13
Author:haileyg
File Name: Thunderbowl Drainage Report.pdf
Throughout the rest of the
Drainage Report an impervious
area of 27% was used, not 31%.
Based off Table 1, 27% seems
accurate. Please verify.
Thunderbowl Drainage Report.pdf (1)
Water service linesshall be as short as
feasible. There is awater main along
Thunderbowl Ln southof the property which
could be tapped.
Utilities shall be routed
around the raingarden
to avoid damage from
additional infiltration.
culation
uirements, WCE calculated the total area of the basins, the impervious area
centration of the basins. Overall, the basins total area equals 0.693 acres,
uals 0.212. The time of concentration for existing basins was found to be
usness of 31% percent, the WQCV in watershed inches is 0.065 in (see Ap-
e, the WQCV over the tributary area of 0.693 acres is 163.6 cf (0.065 ac X
/ 12 in). The proposed grading of the site, as well as pipe networks, route
ng the north end of the lot. This area provides 484.8 cf of detention ((10ft X
equate for the detention required for the 100 year storm (429 cf).
ation
Pipe D Pipe A Rain Garden PB:1.0 Rain Garden
DS 1 Inlet 10 Pipe D Pipe A Rain Garden PB:1.0 Rain Garden
ongue 1 Inlet 4 Pipe A Rain Garden PB:1.0 Rain Garden
ongue 1 Inlet 4 Pipe A Rain Garden PB:1.0 Rain Garden
y Trench Drain Pipe B Rain Garden PB:1.0 Rain Garden
Pipe B Rain Garden PB:1.0 Rain Garden
y Trench Drain Pipe B Rain Garden PB:1.0 Rain Garden
y Trench Drain Pipe B Rain Garden PB:1.0 Rain Garden
Throughout the rest of the
Drainage Report an impervious
area of 27% was used, not 31%.
Based off Table 1, 27% seems
accurate. Please verify.
The water service has been
shown
Utilities have been routed
around rain garden.
The report has been updated.
1/16/18
1/16/18
1/16/18
1/16/18
1/16/18
1/16/18
1/16/18
1/16/18
1/16/18
1/16/18
1/16/18