HomeMy WebLinkAboutFile Documents.395 Thunderbowl Ln.0255.2018 (26).ARBK4/4/12 ANSI/APSP/ICC-‐
15
Standard
Writing
Committee
Form 1
of
2
1.
_________
gallons ___
2.
_________
gpm ___
3.
_________
gpm ___
4.
_________
gpm ___
5a.
_________
inches ___
5b.
_________
inches ___
5c.
_________
inches ___
5d.
_________
inches ___
6a.
___________________
6b.
_________
sq.
ft.___
7.
_________
inches ___
Table 1
8a.
________________
8b.
_________
gpm
___
___
a.
Pump
model
b.
Pump
flow
(§5.3.2.1,
5.3.2.2:
Applicable
Curve
A
or
C
gpm
flow
listed
in
database)
d.
Minimum
return
branch
pipe
diameter
(Calculate:
Item
4.
______(gpm)
÷
Branch
Pipes
______(quantity)
=
branch
flow
rate
_______(gpm).
Enter
the
smallest
pipe
size
from
Table
1
with
a
8
fps
flow
capacity
the
same
or
more
than
the
calculated
return
branch
flow
rate.)
6.
§5.4.1:
Filter
type
and
size:
a.
Filter
type:
(Cartridge,
DE,
Sand)
b.
Minimum
filter
area
(Calculate:
item
4.
_______(gpm)
÷
filter
factor
________)
Filter
factors:
Cartridge=0.375,
Sand=15,
Diatomaceous
Earth=2
7.
§5.4.2:
Backwash
valve:
____Yes,
____No?
(When
using
a
backwash
valve,
enter
result
of
item
5c
or
2
inches
whichever
is
larger)
8.
Pump
selection:
§5.3.2.1:
Pools
17,000
gallons
or
less,
select
pump*
from
the
database
with
a
Curve-‐A
gpm
flow
equal
to
item
2
or
less.
§5.3.2.2:
Pools
17,001
gallons
or
more,
select
pump*
from
the
database
with
a
Curve-‐C
gpm
flow
equal
to
item
2
or
less.
*Multi-‐
speed
pumps
must
have
one
speed
listed
that
satisfies
this
requirement.
3.
§5.2.2:
Auxiliary
Pool
Load:
____Yes,
____No?
(Enter
the
highest
“auxiliary
pool
load”
to
be
powered
by
the
swimming
pool
filtration
pump.
Do
not
add
auxiliary
pool
load
flow
rates
together,
only
the
highest
is
used.)
4.
Calculated
maximum
flow
rate
(Item
2
or
item
3,
whichever
is
larger.)
5.
§5.5.1:
Pipe
sizing:
a.
Minimum
suction
pipe
diameter
(Enter
the
smallest
pipe
size
from
Table
1
with
a
6
fps
flow
capacity
the
same
or
more
than
item
4.)
b.
Minimum
suction
branch
pipe
diameter
(Calculate:
Item
4.
______(gpm)
÷
Branch
Pipes
______(quantity)
=
branch
flow
rate
_______(gpm).
Enter
the
smallest
pipe
size
from
Table
1
with
a
6
fps
flow
capacity
the
same
or
more
than
the
calculated
suction
branch
flow
rate.)
c.
Minimum
return
pipe
diameter
(Enter
the
smallest
pipe
size
from
Table
1
with
a
8
fps
flow
capacity
the
same
or
more
than
item
4.)
OWNER:CONTRACTOR
PHONE:
DATE:
This
information
sheet
was
prepared
by
the
APSP-‐15
Residential
Swimming
Pool
and
Spa
Energy
Efficiency
Standard
Writing
Committee
of
the
Association
of
Pool
and
Spa
Professionals
(APSP).
It
is
not
part
of
the
American
National
Standard
ANSI/APSP/ICC-‐15
2011
but
is
included
for
information
only.
Contractors
should
acquire
and
comply
with
the
ANSI/APSP/ICC-‐15
2011
standard
which
can
be
purchased
at
www.apsp.org.
1.
§5.2.1:
Calculated
pool
volume
a.
Gallons:
___________
;
or
b.
Calculated
Gallons:
________(surface
area)
X
________
(average
depth)
X
7.48
(gal/ft^3)
=
_________
2.
§5.2.1:
Calculated
maximum
filtration
flow
rate
(Pool
volume
÷
360
or
36gpm
whichever
is
larger)
ANSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS
PROJECT
NAME:
AND
ADDRESS
CONTRACTOR
NAME
AND
ADDRESS:
Pipe Size: 1.5" 2" 2.5" 3" 3.5" 4" 5" 6"
Nominal GPM @ 6 fps 38 63 90 138 185 238 374 540
Nominal GPM @ 8 fps 51 84 119 184 247 317 499 720
Print Save As PDF
Lot #7 Thunderbowl
395 Thunderbowl Lane
Aspen, CO 81611
Aspen Extreme II, LLC
Even Flow Pools
3157 W 26th Ave
Denver, CO 80211
(303) 995-3591 4/18/2019
8,399
0
8,399
36
4
4
36
1.5
36 1 36
1.5
1.5
36 1 36
1.5
Cartridge
36 0.375
96.0
2.0
Pentair VS3050
36
06/18/2019
4/4/12 ANSI/APSP/ICC-‐
15
Standard
Writing
Committee
Form 2
of
2
Component Section Check
4.4.1.1
4.4.1.2
4.3.1.3
4.3.2
5.1.1
5.3.1
5.3.3
5.3.4
5.5.2
5.5.3
5.5.6
Pool
systems
Pool
filter
pump
listed
in
database
Pool
filter
pump
with
total
horsepower
1.0
or
more
is
multi-‐speed
Multi-‐speed
pump
controller
programmed
to
default
to
the
filtration
flow
rate
when
no
auxiliary
pool
loads
are
operating
within
24
hours
and
programmed
with
temporary
override
capability
for
servicing.
Single-‐speed
pump
controller
capable
of
operating
pump
during
off-‐peak
electric
demand.
Pipe
before
pump
has
at
least
4
diameters
of
straight
pipe.
System
installed
with
solar,
or
setup
for
the
future
addition
of
solar
heating
equipment
by
installing
18
inches
of
horizontal
or
vertical
pipe
after
the
filter
and
before
a
heater,
or
built-‐in
or
built-‐up
connections,
or
dedicated
pipe
to
and
from
the
pool.
Directional
inlets
for
mixing
pool
water.
ANSI/APSP/ICC
15
ENERGY
EFFICIENCY
COMPLIANCE
INFORMATION
FOR
RESIDENTIAL
SWIMMING
POOLS
Requirements
Heaters
Heater
has
no
pilot
light
Readily
accessible
on-‐off
switch
mounted
outside
of
the
heater
No
electric
resistance
heating
unless
for
inground
spa
with
tight
fitting
cover
with
R-‐6
insulation,
or
for
pool
with
60%
of
documented
pool
heating
from
on-‐site
solar
or
recovered
energy.
Heater
efficiency:
gas/oil
fired
heater
efficiency
at
least
78%,
heat
pump
COP
at
least
4.0
4
4
4
4
4
4
4
4
4
4