HomeMy WebLinkAboutFile Documents.395 Thunderbowl Ln.0255.2018 (2).ARBK395 Thunderbowl ‐ WELS Comments 02.12.2019      Written Responses 02.22.2019    Page: IR‐2.0 IRRIGATION PLAN  How will these native grass areas be irrigated; Note number 4 notwithstanding?  Response: Irrigation equipment relocated along property line to serve all native grass, note #4 removed.    Page: IR‐2.0 IRRIGATION PLAN   Trees should be on separate valves from shrubs, ground‐covers, and turf as per WELS Section 6.2.7 (5.2.7  in newer version). Revise plans in all cases.   Response: Dedicated tree irrigation provided to all trees within planting bed.     Page: IR‐2.0 IRRIGATION PLAN  WELS Section 6.1.3 (5.1.3 in newer version) requires a lockable master valve   Response: Lockable master valve & construction note included (Note #4)    Page: IR‐2.1 IRRIGATION PLAN‐ROOFTOP  Provide the reasoning for overhead spray irrigation versus subsurface on these two roof gardens. Also,  why is one side a medium water usage and the other side a low water usage when they appear to be  utilizing the same low water plants? Your hydrozone plan calls out green roofs as low water.   Response: Green roof planting material consists of a seed mix, which can be difficult to establish with  sub‐surface irrigation. All green roof irrigation indicated as Low water.     Page: L002 notes  Include all the language of WELS Section 5.3 (4.2 in newer version) regarding 4" mulch spec   Response: The language of WELS Section 4.2 regarding mulch has been added to the notes.      06/18/2019 Page: L401 site plan  There aren't any high water zones listed in your water budget worksheet. Revise plans accordingly.   Response: High water zones have been revised per water budget worksheet.    Page: L401 site plan  Where is the mowed native located on this plan?   Response: Mowed native hatch has been added to L401.    Page: L401 site plan  Trees should be medium water as per your water budget worksheet   Response: Trees have been revised to medium water.    Page: L401 site plan  Trees should not be planted within the 10‐ foot utility easement.   Response:  Trees have been relocated from the 10’ utility easement.    Page: L401 site plan  Trees should not be planted over water main extension   Response: Trees have been adjusted to allow separation of root ball from water main extension.    06/18/2019