File Documents.395 Thunderbowl Ln.0002.2020.BCHO
0002-2020-BCHO_BuildingComments_1 Subject: PlanCheck Page: A-7.22 ELECTRICAL EQUIPMENT ENCLOSURE AND CONDENSER ENCLOSURE Page Index: 2 Author: nickt Color: File Name: 395 Thunderbowl Ln - CHANGE ORDER 2 - ARCHITECTURAL.pdf Electric meters and means of disconnect may not be enclosed unless you can clearly detail the enclosure to not encroach on the working space and dedicated equipment space requirements of 2017 NEC 110.26. 395 Thunderbowl Ln - CHANGE ORDER 2 - ARCHITECTURAL.pdf (4) Subject: PlanCheck Page: A-7.22 ELECTRICAL EQUIPMENT ENCLOSURE AND CONDENSER ENCLOSURE Page Index: 2 Author: nickt Color: File Name: 395 Thunderbowl Ln - CHANGE ORDER 2 - ARCHITECTURAL.pdf At all equipment screens, provide and dimension the following per 2015 IMC 306: 1. 30"x30" clear working space in front of the control side of each piece of equipment for service access. 306.1 2. Provide a door that when opened, provides a minimum 24" clearance, provided the equipment can be removed without dismantling the screen. Otherwise, make the door wide enough to remove the appliance. 306.2 3. Provide clearances as required by manufacturer's installation instructions. Subject: PlanCheck Page: A-7.29 NORTH PATIO AND POOL PLAN Page Index: 6 Author: nickt Color: File Name: 395 Thunderbowl Ln - CHANGE ORDER 2 - ARCHITECTURAL.pdf Provide pool and spa drawings complying with the 2015 ISPSC (International swimming pool and spa code). Provide completed APSP-15 worksheets for the pool and spa. Worksheet can be found here: https://www.apsp.org/portals/0/Fi leDownloads/APSP-15%20Com pliance%20Information%20Shee t.pdf Subject: PlanCheck Page: A-7.29 NORTH PATIO AND POOL PLAN Page Index: 6 Author: nickt Color: File Name: 395 Thunderbowl Ln - CHANGE ORDER 2 - ARCHITECTURAL.pdf Treads must be the same dimension unless broken up by a landing (landing minimum depth 36"). Stairways with 4 or more risers must have at least one handrail (with ends returning). 2015 IRC R311.7.5.2, R311.7.6, R311.7.84'-81/2"51/2"6'-9"51/2"7'-11/4"1'-3"3'-1"5'-6"5'-6"6'-6 "1'-10"7" DIAMETER CUT OUT AT METERS WOOD SIDINGDOORS TO BE CLAD WITHWOOD SIDING, FLUSH TOWALL SIDINGSIDING JOINTS TO ALIGN ONDOORS AND WALLS ELECTRICAL EQUIPMENTMOUNTED ON WALLS(SHOWN DASHED BEYOND) WOOD SOFFIT TYPICAL WOOD SIDING LEVER HANDLES, TBD PV METERHOUSEMETER PVDISCONNECT GENERATOR+/S C/T CAN HOUSEDISCONNECT 54 UIP. AND CONDENSER ENCLOSURE - ENLARGED SOUTH ELEVATION A STANDING SEAM METAL ROOF 2X8 FASCIA BOARD -CLAD WITH SHEETMETAL CHANGE ORDER 2 CHANGE ORDER 2 CHANGE ORDER 2 Electric meters andmeans of disconnectmay not be enclosedunless you can clearlydetail the enclosure tonot encroach on theworking space anddedicated equipmentspace requirements of2017 NEC 110.26. 2'-31/2"4'-2"4'-2"2'-111/2"8" 3'-8"-CLR 3'-8"-CLR 3'-8"-CLR 11"2'-01/2" EQ PV METERHOUSEMETER PVDISCONNECT GENERATOR+/S C/T CAN 8"5'-10"31/2"1'-1"6"101/25'-21/2"-CLRAt all equipment screens, provide and dimension the following per 2015 IMC 306: 1. 30"x30" clear working space in front of the control side of each piece of equipment for service access. 306.1 2. Provide a door that when opened, provides a minimum 24" clearance, provided the equipment can be removed without dismantling the screen. Otherwise, make the door wide enough to remove the appliance. 306.2 3. Provide clearances as required by manufacturer's installation instructions.-6"4"1'-6"4"1'-6"4"1'-6"4"1'-6"4"1'-7"1'-4"2'-9"1'-4"14'-91/2" 81/4"2'-4" 82.29° GREEN SPACE DRAIN PLANTING BETWEENCONCRETE - TYP. POOL COPING POOL COPING POOL COVER W/REMOVEABLE PANELS PLANTING BETWEENCONCRETE - TYP. POOL COVER W/REMOVEABLEPANELS DRAIN JOINT AT SNOWMELT/ NON SNOWMELT POOL VAULT - SHOWN DASHED BELOW GRADE - SEE SHT A-7.34 FORINFO. POOL VAULT ACCESS HATCH - SEE SHT A-7.34 FOR INFO.4R @ 5 1/16" EACHSLOPE: 1/4" / FTPOOL-SEE SHOP DRAWINGS FORFURTHER INFO. 98'- 3 1/2" SPA-SEE SHOP DRAWINGSFOR FURTHER INFO.98'-3 1/2" BUILDING ENVELOPE 6'-91/4"2'-6"1'-0"10'-0"1'-0"4" 2'-4"2'-8"30'-6"2'-8"'-3"17'-01/4"31/2"3'-1"'-0"14'-4"PLANTER PLANTER PRIVACY FENCE COLUMN CLEAN OUT ROOF ABOVE 99'- 11 3/4" 100'- 1 7/16"100'- 1" 99'-11 3/4" 100'- 1 3/16" 99'-11 3/4" 99'- 11 3/4" 99'- 11 3/4" -T.O.D. -T.O.S. -T.O.D. = T.O. COPING -T.O. COPING -T.O. COPING -T.O. COPING -T.O.S. 9 - -T.O.G. -T.O.G. 102'- 1 3/4" -T.O. PLANTER 1A-7.31 5A-7.30 2A-7.30 4A-7.30 3A-7.31 3A-7.30 Provide pool and spa drawings complyingwith the 2015 ISPSC (Internationalswimming pool and spa code). Provide completed APSP-15 worksheets for the pool and spa. Worksheet can be found here:https://www.apsp.org/portals/0/FileDownloads/APSP-15%20Compliance%20Information%20Sheet.pdf 4"1'-6"4"1'-6"4"1'-6"4"1'-6"4"1'-6"4"1'-6"4"1'-7"1'-4"2'-9"1'-4"4"1'-6"4"1'-6"4"1'-6"4"1'-6"4"1'-6"4"1'-6"1'-10"14'-91/2" 17'-5" 16'-6" 2" PLANTER GREEN SPACE GREEN SPACE PLANTING BETWEENCONCRETE - TYP. POOL COVER W/REMOVEABLE PANELS JOINT AT SNOWMELT/ NON SNOWMELT4R @ 5 1/16" EACHSLOPE: 1/4" / FTSLOPE: 1/4" / FT8'- 3 1/2" 98'-10" 99'-2" 98'-5" SPA-SEE SHOP DRAWINGSFOR FURTHER INFO. 100'-1 1/8"100'-1 1/8" 98'-3 1/2" NG ENVELOPE 2'-8"81/4"1'-31/4"31/2"18'-63/4"'-13/4"1'-63/4"3'-1"8"PRIVACY FENCE ROOF ABOVE 1A-7.32 100'-2 1/2" /4" 100'- 1" 99'-11 3/4" 100'-2 5/16" 99'-11 3/4" 99'-11 3/4" 99'-10 3/4"99'-11 1/4" 99'- 11 3/4" .O. COPING -T.O. COPING -T.O. COPING -T.O.D. -T.O.S. -T.O.S. -T.O.S. -T.O.D. -T.O.S. 99'-11 3/4" -T.O. PLANTER 99'-11 3/4" -T.O.S. -T.O.G. -T.O.G. -T.O.G. -T.O.G. -T.O.G. 4A-7.31 1A-7.31 5A-7.30 2A-7.31 6A-7.30TYP Treads must be the same dimension unless broken up by alanding (landingminimum depth 36"). Stairways with 4 or more risers must haveat least one handrail(with ends returning).2015 IRC R311.7.5.2, R311.7.6, R311.7.8 Subject: PlanCheck Page: [4] BG- Thunderbowl-L Series_FINAL-L100 LAYOUT Page Index: 1 Author: nickt Color: File Name: 395 Thunderbowl Ln - CHANGE ORDER 2 - LANDSCAPE.pdf Revise snowmelt extents on landscape plan to match mechanical drawings and REMP worksheet (or remove it from landscape drawings). 395 Thunderbowl Ln - CHANGE ORDER 2 - LANDSCAPE.pdf (3) Subject: PlanCheck Page: [5] BG- Thunderbowl-L Series_FINAL-L200 MATERIALS Page Index: 2 Author: nickt Color: File Name: 395 Thunderbowl Ln - CHANGE ORDER 2 - LANDSCAPE.pdf Provide sheet L800 Subject: PlanCheck Page: [5] BG- Thunderbowl-L Series_FINAL-L200 MATERIALS Page Index: 2 Author: nickt Color: File Name: 395 Thunderbowl Ln - CHANGE ORDER 2 - LANDSCAPE.pdf Provide installation instructions for fire feature showing required clearances to combustibles and demonstrate on your plans that you meet the requirements. Subject: PlanCheck Page: 1 Page Index: 1 Author: nickt Color: File Name: 395 Thunderbowl Ln - CHANGE ORDER 2B - REMP CALCS.pdf Per the mechanical plans, you have 4563 sqft of non exempt plus 18 of exempt for a total of 4581.28. 395 Thunderbowl Ln - CHANGE ORDER 2B - REMP CALCS.pdf (1)T W W W W WWWGASGASGASW W W W SS SS SS SS SS W W W W SS SS SS SS SS W W W W 1. SITE WALL WIDTH 8" UNLESS OTHERWISE NOTED; CONFIRM WITH STRUCTURAL. 2. REFER TO CIVIL FOR ALL FINAL GRADING, DRAINAGEAND UTILITIES. NOTES EXPANSION JOINT SAW CUT JOINT LEGEND PROPERTY LINE SNOWMELT EXTENTS; 3,665.6 SF EASEMENT 0 5 10 scale north L100 layout plan 12/15/2017 pricing set07/20/2018 change orde 11/27/2019 change orde date l issue © copyright bluegreen 1 2 change orde 12/18/2019 Revise snowmeltextents on landscapeplan to match mechanical drawings and REMP worksheet (or remove it from landscape drawings). 5' ACTIVITY ENVELOPE STRSTRSPA POOL PAVING WITH PLANTED JOINTS FIRE FEATURE 1 L800 4L800 4 L803 5 L800 4 L803 RAISED PLANTER3L800 3 L800 SIM. DRAIN RE CIVIL 2OUTDOOR SHOWER TILE SCREENING TRELLIS AT-GRADE PLANTER DRAIN RE CIVIL RAISED PLANTER SIM. Provide sheet L800 5' ACTIVITY ENVELOPE PAVING WITH PLANTED JOINTS FIRE FEATURE OUTDOOR GRILL AND COUNTER RE ARCH 1 L800 5 L800 4 L803 RAISED PLANTER3 L800 SIM. RAIN CHAIN WITH HEAT TRACE TO EXTENDTO INLET AND GRAVEL; RE ARCH AND CIVIL Provide installationinstructions for fire feature showing required clearances tocombustibles and demonstrate on your plans that you meetthe requirements. Phone: ` A.RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAMSheets showing snowmelt, pool, spa, and solar/GSHP information: Do you have snowmelt or a spa that has been exempted by the buiding official? Hydro Snowmelt Electric Snowmelt Pool Existing To be Removed Existing to Remain 0.00 sqft 0.00 sqft 0.00 sqft New 4581.28 sqft 215.00 sqft New (exempt)18.00 sqft Total on site 4599.28 sqft 0.00 sqft 215.00 sqft Total Snowmelt on site Boiler Efficiency 98.0%100%98.0% Mitigation Fee 29,83 $ Total Fee for Mitiga B.ON-SITE RENEWABLE CREDITS Supplemental System Use PV WorksheetPhotovoltaic System Use Thermal WorksheetHot Water Panels Use GSHP CertGround Source Heat Pu Other Approved System Total Mitigation Cre Onsite Renewable Offsets: How many KiloWatts of PV (solar electric) would I n or How many square feet of SHW (solar hot water) would I R-REMP Amount Previously Paid on This Pe TOTAL R-REMP F Refund (includes minus $ C. PREPARED BY: Print Name: Signature: Phone & EMail:970-748-8520 , david@aec-va M-124, M-602 $158,942.37 David Denio 4599.28 sqft 970-925-3444 Yes (en Per the mechanical plans, you have 4563 sqft of non exempt plus 18 of exempt for a total of 4581.28.