HomeMy WebLinkAboutFile Documents.395 Thunderbowl Ln.0002.2020 (4).BCHOProject Address: 395 Thunderbowl Lane
Master Permit #: 0153.2017.ARBK
Submission: Change Order 2
Narrative of Changes:
Architectural Sheets:
A-2.1 – Proposed locations of proposed Mechanical Enclosures. Removal of Previously Permitted Water
Runnel & Location of Pool Vault & Various Detail Callouts
A-7.22 – Clouded areas show plans, Elevations and Sections at Proposed Mechanical Enclosures at East
side of Building
A-7.23 – Clouded areas show Mechanical Enclosure plan at West side of Building
A-7.24 – Clouded areas show Elevations of Mechanical Enclosure at West side of Building
A-7.25 – Clouded areas show details of Fencing at Mechanical Enclosures (East and West)
A-7.30: various details as called out on Sheet A-2.1
A-7.31: various details as called out on Sheet A-2.1
A-7.32: various details as called out on Sheet A-2.1
A-7.33: Outdoor Shower - Plan and Elevations (per callout on A2.1)
A-7.34: Pool vault and Access Hatch – Plans and Sections (per callout on A2.1)
Civil Sheets:
C302 - Clouded areas indicate locations of proposed Mechanical Enclosures & associated site drainage
C301:
a. Clouded areas indicate revised locations of drains and grading
b. Additional decorative Swale
c. Sand Filter has been lowered by 1‘-0”
C400: Change in pipe joint location, min. carrying capacity unaffected
C500 : Decorative rock swale detail AND Foundation drywell overflow pipe detail added to set
C800: Added decorative rock swale AND foundation drywell overflow pipe
01/21/2020
Landscape Sheets:
L100 : Removal of Previously Permitted Water Runnel & Location of Pool Vault & Various Detail Callouts
L200 : Revised material quantities due to mech enclosures
L400: Revision to Planting schedule
L401: Revisions to quantity, types and location of plantings
L801: Revisions to paving with Planted Joints Detail 4 & Revision to Pedestrian Pedestal Detail
Structural Sheets:
S5.08: Site Retaining Wall Details (As referenced to Architectural Sheets)
SDA-2: Typical site wall at proposed mechanical enclosures
SDA-14: Section at proposed Condenser Enclosure at East side of Building (West-similar)
SDA-15: Section at Stepping Slab at proposed Mechanical Enclosure at west side of building
SDA-16: Section at proposed Electrical Enclosure at East side of building
Pool Vault Sheets:
Technical Drawings for Pre-fab Pool Vault
Mechanical Sheets:
M-124: revised area of Snowmelt at North Patio
M-602: Revised area of snowmelt at Exterior patio
REMP CALCS: revised to reflect additional area of snowmelt
01/21/2020