HomeMy WebLinkAboutFile Documents.405 S Monarch St.0079.2017 (4).ARBK ELEMENT ENVIRONMENTAL | Aspen Constructors 032417 1 Property Address 233 E. Cooper Aspen, CO 81611 TABLE OF CONTENTS 1.0 - Scope of Work 2.0 - Sampling Requirements 3.0 - Sampling Methodology 4.0 - Laboratory 5.0 - Suspect Materials Sampled 6.0 - Table of Results 7.0 - Description of Sampling Area 8.0 - Conclusion - Lab Report - Certifications Asbestos Samples Analyzed: 5 Positive Asbestos Samples: 0 _____________________________________________ Asbestos Sampling Report Date: 3/30/2017 Date of Inspection: 03/24/2017 Client: Aspen Constructors 309 AABC, Unit G Aspen, CO 81611 Attn: Justin Labier Building Inspector: Joshua Johnson CDPHE #18401 189 County Rd. 135 Glenwood Springs, CO 81601 josh@elementenv.co (970)274-3139 Received 5/08/2017 10:07:47 AM ELEMENT ENVIRONMENTAL | Aspen Constructors 032417 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a water loss. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remediation. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: 2.1- Surfacing Materials- >1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2- Miscellaneous materials- Minimum of 1 sample 2.3- Thermal Systems Insulation (TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are segregated into separate homogenous areas. The size is determined and then samples are taken. The samples are taken in a random numerical sequence. 4.0- Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401, performed the inspection. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or <1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample most have an additional “point count” performed to be considered less than 1% and not be regulated by the CDPHE. The lab’s documents with analyses and findings are found below. Received 5/08/2017 10:07:47 AM ELEMENT ENVIRONMENTAL | Aspen Constructors 032417 3 5.0- SUSPECT MATERIALS SAMPLED • Texture • Drywall • Tape • Joint Compound • Fireproofing 6.0- TABLE OF RESULTS HOMOGENOUS AREA DESCRIPTION OF AREA CATEGORY & FRIABILITY NUMBER OF SAMPLES APPROXIMATE SQ.FT. % AND TYPE OF ASBESTOS FOUND (A) Smooth Roll Texture S /N/A 3 ~800f2 No Asbestos Detected (B) Fireproofing M /N/A 2 ~400f2 No Asbestos Detected Key: S- Surfacing M- Miscellaneous T- Thermal Systems Insulation N- No Y- Yes N/A- Not Applicable 7.0- DESCRIPTION OF SAMPLING AREA The ceiling and some of the walls in the living room were partially removed from getting water damaged. The materials that were still in place matched those removed and were tested. 8.0- CONCLUSION No asbestos was detected in any of the samples. Josh Johnson, Received 5/08/2017 10:07:47 AM ELEMENT ENVIRONMENTAL | Aspen Constructors 032417 4 Received 5/08/2017 10:07:47 AM ELEMENT ENVIRONMENTAL | Aspen Constructors 032417 5 Received 5/08/2017 10:07:47 AM ELEMENT ENVIRONMENTAL | Aspen Constructors 032417 6 Received 5/08/2017 10:07:47 AM