ForceField® FireGuard E-84®
Intumescent Paint
For Gypsum/ Wood/ OSB
Generic Type Water-based intumescent coating designed for the fire
protection of gypsum and wood.
Description Thin film intumescent coating that creates a fire retardant
and fire resistant barrier on a wide range of building surfaces
including gypsum, wood, and steel (see tech data sheet for
steel).
Listed and certified by Guardian Fire Test Laboratories Inc.
Features -ASTM E-119 ASTM E-84 Tested
-Decorative Finish- Gives a smooth decorative finish.
-Can be top-coated to color choice.
-Can be brushed on, rolled on, or sprayed on
-Durable finish- Provides a hard, impact and abrasion
resistant surface
-Topcoat finishes smooth
-Thin film coating- space saving footprints
-Low VOC content
-LEED compliant
Color White
Finish Smooth
Primers Can be used as a finished coat or a primer.
For interior space a topcoat is optional. For exterior
Topcoats applications the material must be top coated with an
impermeable exterior coating. The choice of topcoat will
depend on project requirements and mil thickness of
intumescent coating. FireGuard E-84® Intumescent Coating
must be allowed to cure for 4-5 days prior to the application
of a topcoat. Application must be protected from the
elements until topcoat is in place. When applying a top coat,
dry mil applications thickness to achieve a desired rating may
change.
Wet Film Up to 25 - 30 mils per coat
Thickness
Dry Film Up to 13.5 – 16.2 mils per coat
Thickness
Solids Content By volume 54%
Coverage rate 866ft²/Gal at 1mil
86ft²/Gal at 10mil
28.9ft²/Gal at 30mil
Allow for loss in mixing and application.
VOC Content 3.6 g/l
Limitations Not for use on exterior environments or for interior steelwork
that will be exposed to freeze/thaw cycling or long-term
surface temperatures over 140˚F (60˚C) in normal use
without the use of a suitable topcoat.
Application Conditions
General Prior to application surfaces need to be cleaned by removing
all oil, grease or any loose particles that may interfere with
the bond of ForceField® FireGuard®. It is highly
recommended to prime drywall substrates before the
application of FireGuard E-84®.
On wood substrates where the wood is extremely old and
dried out, it will be necessary to scrape off any old flaking off
paint (if painted) and prime the surface before the
application of FireGuard E-84®.
Standards Tested To Results
ASTM 2768 / ASTM E-84 30 min Extended Flame Spread- 0 Smoke Index- 5
ASTM E-84
ASTM E-119 1 & 2 Hour on gypsum and wood
wall and floor/ceiling assemblies UL 263
NFPA 251
ULC-S-101
Mixer Use ½” electric or air driven drill with a slotted paddle mixer
(300rpm under load).
Mixing Fireguard® must be mixed using a ½” electric or air driven drill
with a slotted paddle or jiffy mixer blade. Mix material for a
minimum of 5 minutes to achieve the necessary texture
required before spraying.
Thinning Do not thin.
Tinting Do not tint.
Brushed or Rolled Generally creates an 11 to 12 mil wet application.
Multiple coats will be required to meet
specifications to the job requirements. Allow each
coat to completely dry to touch before applying
next coat.
Airless Spray A single coat, built up with a number of quick
passes, allows greater control over quantities,
thickness and finish. In most conditions, it is
advantageous to apply two thin coats rather than
one thick coat
Performance Data
Mixing & Thinning
Application Procedures
March 2015.
This technical data sheet was designed incorporating information to the best of knowledge that was true and accurate on the date that this information was published. No guarantee of accuracy is
given or implied. We guarantee our products to conform to Shield Industries quality control. No other warranty of any kind is made by Shield Industries, Inc. To determine needs for specific
application and correctness of use it is important to reference manufacturer specification sheets and contact Shield Industries directly. ForceField®, FireGuard® & FireGuard E-84® are registered
trademarks of Shield Industries, Inc.
Shield Industries, Inc.
131 Smokehill lane. Woodstock, GA 30188 (770) 517-6869
Substrates & Surface Preparation
Received
5/11/17
Cleanup Pump, Gun, Tips, Hoses, and Mixers should be cleaned once per
day with clean water.
Safety It is recommended protective equipment should be worn when
applying Fireguard®, including spray suits, eye protection,
gloves, and respirators. Refer to Fireguard® Material Safety Data
Sheet.
Ventilation Ventilation should not be less than 4 complete air exchanges
per hour until the material is dry.
General If coating becomes damaged, rebuild required thickness by
spray, brush or roll. When dry, smooth and finish with topcoat
to match. Damaged areas must be abraded back to a firm edge
by sanding or scraping. The topcoat should be abraded back 1”
(25.4 mm) from the damaged area. The surface must be clean
and dry before applying Fireguard E-84®.
Uncertainty Measurement in Guardian’s fire testing is less than 1% as per
ASTM E 2536-06.
Guardian is accredited and meets the requirements of ISO/IEC 17025 as
verified by ANSI/ASQ National Accreditation Board/ A CLASS. Refer to
certificate and scope of accreditation report AT1247. Guardian also is
accredited as an inspection agency per ISO 17020 through ANSI/ASQ
National Accreditation Board/ ACLASS, Report 1547.
N.B.: ANSI/ASQ/ACLASS is a signatory member of the International
Laboratory Accreditation Cooperation’s (ILAC) Mutual Recognition
Arrangement (MRA).
ANSI/ASQ/ACLASS accreditation of Guardian ensures global recognition for
Guardian’s services.
Shelf Life 1 year from production date
*Shelf Life: (actual stated shelf life) when kept at recommended
storage conditions and in unopened original container.
Shipping Weight approximately 12 lbs. per gallon (1.44 kg/l)
Storage Store indoors in a dry environment between 33˚F-100˚F (1˚C -
38˚C). Protect from freezing.
Packaging
5 Gallon 55 Gallon Tote
Cleanup & Safety
Maintenance
Testing/ Certifications
Storage, Packaging & Handeling
Application Rates At an ambient temperature of 70˚F (21˚C), the
following application rates are applicable:
25 – 30 mils per coat (wet)
24 hour recoat time between coats
1 coat per day
*Fireguard can be recoated when previous coat
has a shore D hardness of 50 measured at 70˚F (21˚C)
Wet Film Thickness Frequent thickness measurements with a wet film
gauge are recommended during the application
process to ensure uniform thickness
Dry Film Thickness Final thickness can be measured using an
electronic dry film thickness gauge. Positector 200
or equivalent may be used. Wet mil thickness dries
to 54%. (i.e. 20mil wet = 10.6mil dry)
Listed below are general equipment guidelines for the application of this product when
spray applied.
Airless Spray Airlessco LP540 or equivalent
Spray Gun Standard airless spray gun
Spray Tips 0.019”- 0.021”
Fan Size 4”-10” (depending on section being sprayed)
Hose Length 150’ (45m)
Material Hose 3/8” (9.25mm) I.D. minimum
Whip Hose ¼” (6.35 mm) I.D minimum (optional)
Condition Material Surface Ambient Humidity
Minimum 70˚F (21˚C) 50˚F (10˚C) 50˚F (10˚C) 0%
Maximum 100˚F (38˚C) 125˚F (52˚C) 110˚F (43˚C) 85%
Fireguard must be protected from exposure to weather. Protect from freezing.
Surface Temp. & 50 % Relative
Humidity
Dry to Recoat
77˚F (25˚C) 24 Hours
*It is recommended to apply one per day. Drying time will vary with temp. Thinner coats
as well as air movement will help drying time. Another coat of Fireguard® can be applied
when previous coat has a Shore D hardness of 50 measured at 70˚F (21˚C). It can be top
coated when a hardness of 60 is achieved after 4-5 day cure time.
Application Procedures
Application Equipment Guidelines
Application Conditions
Curing Schedule
May 2015
This technical data sheet was designed incorporating information to the best of knowledge that was true and accurate on the date that this information was published. No guarantee of accuracy is given
or implied. We guarantee our products to conform to Shield Industries quality control. No other warranty of any kind is made by Shield Industries, Inc. To determine needs for specific application and
correctness of use it is important to reference manufacturer specification sheets and contact Shield Industries directly. ForceField®, FireGuard® & FireGuard E-84® are registered trademarks of Shield
Industries, Inc
Shield Industries, Inc.
131 Smokehill lane. Woodstock, GA 30188 (770) 517-6869
Received
5/11/17