Loading...
HomeMy WebLinkAboutFile Documents.415 E Hyman Ave.0078.2017.ACBKDESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO415 E. HYMAN AVE.MTE 1616 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED PROJECT INFORMATION 1.2 01/10/2017SCHEMATIC DESIGN 02/15/2017PERMIT SET 6/6/2017CHANGE ORDER I 1. The Contract Documents include: (1) general notes; (2) architectural, mechanical, and structural drawings. All additional specifications, details, drawings, clarifications, or changes shall automatically become part of the Contract Documents. Any discrepancy between any components of any of the drawings shall be reported to the Architect immediately for clarification. 2. Alius Design Corps, LLC, shall not be liable in any way for problems which arise from failure, by any third party or any party to this Contract, to follow the design plans. The Contractor shall obtain and/or request guidance of Alius Design Corp., with respect to any errors, omissions, inconsistencies, or conflicts or unclear information which may be discovered or alleged. 3. The Plans and Specifications are the intellectual and other property of the Architect and shall not beused without the permission of same. 4. All work shall comply with all state and local codes, ordinances, rules, regulations and laws of building officials or authorities having jurisdiction. All work shall be performed to the highest standards or craftsmanship by all tradesman. Alius Design Corps, LLC., shall not be responsible for overseeing third party work, nor shall Alius Design Corps, LLC., be liable for any errors or omissions of third parties who perform work on the Project. 5. The Contract Documents represent the finished structure. They do not indicate the method of construction. The Contractor shall provide all measures necessary to protect the structure during construction. Observation visits to the site by the Structural Engineer or Architect shall not include inspection of the ____________, nor will the architect or structural engineer be responsible for the contractor's means, methods, techniques, sequences for procedure of construction, or the safety precautions and the techniques, sequences for procedure of construction, or any safety precautions. The Contractor and not the Architect shall be responsible for all Federal and OSHA regulations. 6. THE DRAWINGS ARE NOT TO BE SCALED. Written dimensions must be used. In the event of a discrepancy in dimensions, the Architect should be timely notified for clarification. All dimensions on the drawings shall be verified against the existing conditions. All dimensions are to rough framing or face of concrete unless noted otherwise. 7. The Construction Documents are intended to include all labor, materials, equipment, and services required to complete all work described herein. It is the responsibility of the Contractor to bring to the attention of the Architect any conditions which will not permit construction according to these Construction Documents. 8. The Building Inspector shall be notified by the Contractor if there is need of an inspection as required by the I.R.C., or by any local code or ordinance. 9. LOT STAKED: The Contractor shall arrange for the building to be located and staked after demolition or site clearing, to be approved by the Architect. The Contractor shall review the lot staking and verify, to the best of his ability, its accuracy. The Contractor shall also check the grade where it meets the building to evaluate the consistency with the drawings during excavation. All work to be done by a certified surveyor. 10. RECORD DRAWINGS: Contractor shall maintain a complete set of blue/black-line prints of contract drawings and shop drawings for record mark-up purposes throughout the Contract time. Mark-up drawings during course of the work shall show changes and actual installation conditions, sufficient to form a complete record for Owner's purposes. 11. SOILS AND CONCRETE: The General Contractor shall arrange for a visual site inspection at the completion of excavation by a soils engineer, and the required concrete testing prior to any foundation work. 12. Property lines, utilities and topography shown is representative of information taken from a survey. Contractor shall notify Architect of any discrepancy or variation between the Drawings and actual site conditions. ABREVIATIONS A.F.F. ABOVE FINISH FLOOR ADJ. ADJUSTABLE ALT. ALTERNATE A.B. ANCHOR BOLTS & AND ARCH. ARCHITECTURAL @ AT BM. BEAM BM. PKT. BEAM POCKET BRG. BEARING BLK’G. BLOCKING BOT. BOTTOM BLDG. BUILDING B.O. BY OWNER CLG. CEILING CL. CENTER LINE CLR. CLEAR COL. COLUMN CONC. CONCRETE CONN. CONNECTION CONT. CONTINUOUS DTL. DETAILS DWL. DOWEL E.W. EACH WAY ELEV. ELEVATION EXISTG EXISTING EXT. EXTERIOR FLR. FLOOR FTG. FOOTING FND. FOUNDATION GA. GAUGE G.L. GLU-LAM G.W.B. GYPSUM WALL BOARD HORIZ. HORIZONTAL INFO. INFORMATION INSUL. INSULATION JST. JOIST N.I.C. NOT IN CONTRACT O.C. ON CENTER OPP. OPPOSITE PERF. PERFORATED PL. PLATE PLY. PLYWOOD PROP. LINE PROPERTY LINE REINF. REINFORCEMENT REQ. REQUIRED REV. REVISED SIM. SIMILAR S.F. SQUARE FEET STD. STANDARD THK. THICK T.P. TOP OF PLATE T.L. TOP OF LEDGE T.W. TOP OF WALL TOT. TOTAL TYP. TYPICAL U.N.O. UNLESS NOTED UTHERWISE V.I.F. VERIFY IN FIELD 033 LBB CLIENT RossMore Enterprises 605 E. Main Street Suite 7 Aspen, CO 81611 ARCHITECT Alius Design Corps, LLC 1331 East Sopris Creek Rd. Basalt, CO 81611 719.331.9211 michael@aliusdc.com GENERAL CONTRACTOR Gary M. Johnson GENERAL RENOVATION NOTES 1.0 All existing conditions must be verified by the contractor in the field. Unknown and varied conditions may be found. Notify the structural engineer and/or architect of any structural or architectural conditions found to vary from that indicated from the drawings. Design revisions may be required, and are to be expected as a process of remodel work. 2.0 All new work, details, surfaces, or finishes shall match adjacent existing surfaces unless noted or directed otherwise by the owner or interior designer. Contractor to verify with architect any conflict between existing and new conditions. 3.0 All electrical modifications and/or additions to be as directed by owner/lighting designer during construction. Contractor/lighting designer to verify electrical capacity and review new designs or alterations with architect, prior to implementation. 4.0 All interior electrical fixtures, plumbing fixtures and trim, cabinet design, and other finishes to be at the directive of the owner or interior designer unless noted otherwise in the drawings. Contractor to provide all necessary prep work for installation of any materials as required. 5.0 Structural engineering – if any modifications to the existing structural system are deemed necessary beyond these shown in the drawings, all existing conditions are to be verified in the field by a registered structural engineer before proceeding. The architect will not be responsible for any structural modifications not verified or approved by a structural engineer. 6.0 Contractor will verify and coordinate all openings through floors, ceilings, and walls with all architectural, structural, mechanical, plumbing, and electrical design and construction. ARCHITECTURAL 1.1 TITLE SHEET 1.2 PROJECT INFORMATION 1.3 UNIT BUILDING RELATIONSHIP 1.4 FLOOR AREA CALCS 1.5 FLOOR AREA CALCS / COM CHECK & LIGHTING SPECS 3.1 1/4” FLOOR PLANS 3.2 1/4” FLOOR PLANS 3.3 1/4” FLOOR PLANS 7.1 1 ½” FLOOR ASSEMBLIES AND DETAILS 8.1 INTERIOR ELEVATIONS PROJECT INFORMATION OCCUPANCY CLASSIFICATION ........................................................................................................................................... BUSINESS (B) MAX OCCUPANCY DESIGN LOAD ..................................................................................................................................... SEE SHEET 1.3 ZONE DISTRICT ................................................................................................................................................ COMMERCIAL CORE (CC) LOT SIZE .................................................................................................................................................................................................. N/A PARCEL I.D. ............................................................................................................................................................................. 73718222006 BUILDING SIZE ....................................................................................................................................................................................... N/A 5.1A REFERENCE GRID LINE SPOT ELEVATION WINDOW MARK DOOR MARK ROOM NUMBER DRAWING REVISION ASSEMBLY DETAIL CUT SECTION CUT EXTERIOR ELEVATION DETAIL CALLOUT INTERIOR ELEVATION ROOM 100 F11 1 T. O. RIDGE BEAM 123'-6 1/2" 4.4 1 1 7.1 8.1 1 2 3 4 SYMBOL & MATERIAL LEGEND PROJECT INFORMATION DRAWING INDEX PROJECT DIRECTORY CONSTRUCTION NOTES ABBREVIATIONS CHANGE ORDER I 06/06/2017GENERAL NOTES 415 E. HYMAN AVE. I I I I 8 Received 6/13/17 06/14/ 2 0 1 7 nickt SEE NOTES #1 PLANS DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO415 E. HYMAN AVE.MTE 1616 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED COM CHECK & LIGHTING SPECS 1.5 01/10/2017SCHEMATIC DESIGN 02/15/2017PERMIT SET 6/6/2017CHANGE ORDER I LY4RCS / 30K Applications Recessed Ceiling Mount DESCRIPTION Energy Used 9 W Recessed 4" Round LED With Integral Driver In Connection Box.Colour Temperature 3000° K Fits Where No Other Recessed Fixture Can.Light Output 560 lm Halogen Equivalent 50 W FEATURES & BENEFITS Beam Angle 105° 1/2" Thin - Install Directly Under Joists, Maximum Layout Flexibility CRI 84 Type IC Rated - No Housing Required Driver Input 120V AC or 277V-347V AC 50/60 Hz Fast & Easy To Install - Save On Labour Power Factor 0.98 Driver Inside Connecton Box - No Junction Box Needed Dimming TRIAC Dimmers 10% - 100% (120V only) Approved Location Insulated Ceiling & Damp Locations MOUNTING Air Tight Yes Cut Hole In Ceiling And Snap Fixture In Opening With Attached Spring Clips.Ambient Temperature -40°F (-40°C) to +104°F (+40°C) 2" Above Ceiling Clearance Required For Driver.Projected Life 70% Light Output at 50,000 Hours Certification cULus, cETLus, Energy Star Warranty 5 Year on Fixture & Driver 277V - 347V Driver Option Available Not Dimmable COMPLIANCE Project: Location: Trim Finish: Qty: 4" Round Super Thin Recessed LED 9W Notes: SPECIFICATION tel: 1-844-24-LOTUS (56887) fax. 1-877-561-6306 www.lotusLEDlights.com Warehouses Vancouver, BC Toronto, ON Las Vegas, NV Naples, FL Type IC & Airtight CHARACTERISTICS Body: Durable, Die Cast Aluminum Alloy for Optimal Heat Dissipation. Paint: Oil Based Spray Painted - Scratch Resistant And Smooth Finish. LEDs: 77 Pieces Of Custom Packaged LM80 Epistar 3014. Guaranteed 98% Lumen Maintenance After 6,000 Hours. Strict Binning To Ensure Consistent Light Colour. Driver: 4th Generation Lotus Designed. Field Proven Since 2011. Connection Box: Patented Invention By Lotus LED Lights. Saves Contractors Labour In Installation On Every Job. Testing: Every Single Driver Is Powered For Minimum 24 Hours Together With The Fixture That It Is Shipped With. Every LED Is Visually Checked Before And After The PCB Is Mounted On The Fixture. No Random Tests – We Hand Test Every Fixture & Driver. ORDERING GUIDE Example: LY4RCS / 30K / WH ACCESSORIES Sold Separately Trim Finish Low Volage Extension Cables 6ft - cat # EXC6, 20ft - cat # EXC20 WH : White Max 40 ft Extension Allowed BK : Black BN : Brushed Nickel Rough-In Plates - cat # RIP4 Order 277V - 347V Optional Driver Separately As cat # LLL-LD1535H Goof Ring White OD 5 3/4" - cat # GR4 tel: 1-844-24-LOTUS (56887) fax. 1-877-561-6306 www.lotusLEDlights.com PHOTOMETRIC DATA Warehouses Vancouver, BC Toronto, ON Las Vegas, NV Naples, FL LY4RCS / 30K / Project Title: 415 East Hyman Report date: 06/03/17 Data filename: C:\Users\Michael\Documents\ARCH\Alius Design Corps\Projects\2016\1616_415 E Hyman\Documents\Permit\415 E Hyman_2.cck Page 1 of 2 COMcheck Software Version 4.0.3.1 Interior Lighting Compliance Certificate Section 1: Project Information Energy Code: 2009 IECC Project Title: 415 East Hyman Project Type: Alteration Construction Site:Owner/Agent:Designer/Contractor: 415 East Hyman Aspen, CO 81621 RossMore Enterprises 415 East Hyman St. Aspen, CO 81621 eric@rossmoreproperty.com Michael Edinger A.D.C. 1331 East Sopris Creek Road Basalt, CO 81621 719.331.9211 michael@aliusdc.com Section 2: Interior Lighting and Power Calculation A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B x C) Office 1333 1 1333 Total Allowed Watts =1333 Section 3: Interior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) Office (1333 sq.ft.) LED 1: LED A Lamp 9W:1 23 9 207 Track lighting 1: Wattage based on 15 feet of track 0 0 0 450 Track lighting 2: Wattage based on 15 feet of track 0 0 0 450 Total Proposed Watts =1107 Section 4: Requirements Checklist Interior Lighting PASSES Lighting Wattage: q 1.Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 1333 1107 Passes Controls, Switching, and Wiring: q 2.Daylight zones under skylights more than 15 feet from the perimeter have lighting controls separate from daylight zones adjacent to vertical fenestration. q 3.Daylight zones have individual lighting controls independent from that of the general area lighting. Exceptions: q Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device. q Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a separate switch for general area lighting. q 4.Independent controls for each space (switch/occupancy sensor). Project Title: 415 East Hyman Report date: 06/03/17 Data filename: C:\Users\Michael\Documents\ARCH\Alius Design Corps\Projects\2016\1616_415 E Hyman\Documents\Permit\415 E Hyman_2.cck Page 2 of 2 Exceptions: q Areas designated as security or emergency areas that must be continuously illuminated. q Lighting in stairways or corridors that are elements of the means of egress. q 5.Master switch at entry to hotel/motel guest room. q 6.Individual dwelling units separately metered. q 7.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. q 8.Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either controlling all luminaires, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switching the middle lamp luminaires independently of other lamps, or switching each luminaire or each lamp. Exceptions: q Only one luminaire in space. q An occupant-sensing device controls the area. q The area is a corridor, storeroom, restroom, public lobby or sleeping unit. q Areas that use less than 0.6 Watts/sq.ft. q 9.Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: q Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security. q 10.Photocell/astronomical time switch on exterior lights. Exceptions: q Lighting intended for 24 hour use. q 11.Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts). Exceptions: q Electronic high-frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 5: Compliance Statement Compliance Statement: The proposed lighting alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting alteration project has been designed to meet the 2009 IECC, Chapter 8, requirements in COMcheck Version 4.0.3.1 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Michael T Edinger 06/03/2017Michael Edinger President 6/3/2017 14W LEDme Exterminator II Track Light by WAC Lighting at Lumens.com https://www.lumens.com/14w­ledme­exterminator­ii­track­light­by­wac­lighting­WACP150353.html#cgid=%0A%09%0A%09%0911060%0A%09%0A&&tileInde…1/2 CALL U 877.445.4486 Mon-Fri 6am-6pm PT at 7am-5pm PT Details The WAC Lighting 14W LDme xterminator II Track Light o쮩�ers a slick, modern directional lighting head to suppl ample projection lighting in our indoor space. Made from die-cast aluminum, the 14W LDme xterminator II Track Light allows for 355° horizontal rotation and 180° vertical aiming. Rated for 100,000 hours of life and is dimmale with an LV dimmer (sold separatel.) The 14W LDme xterminator II Track Light dims from 100% - 5%.   WAC Lighting, founded in 1984, has developed a strong reputation for high qualit decorative and task lighting. ased in Garden Cit, New York, WAC Lighting is a leading manufacturer of low voltage, line voltage and LD lighting, including track sstems, transformers, lamps, cainet lighting and recessed downlights.   The 14W LDme xterminator II Track Light is availale with the following:   Details: Designed in 2015 Material: Die-cast Aluminum uperior illumination with compact design 355° horizontal rotation 180° vertical aiming Accomodates one lens accessor and one glare control accessor Rated Life: 100,000 hours Dimming: 100% - 5% Dimmale when used with lectronic low voltage (LV) Dimmer dimmers(not included) Title 24 compliant TL Listed Warrant: 5 Years Functional, 2 Years Finish Made In China Options: Finish: lack, rushed Nickel, White Track Tpe: H-Track, J-Track, L-Track Light Temperature: 2700K, 2700K (90 CRI), 3000K, 3000K (90 CRI), 3500K, 4000K eam pread: 20 Degree, 40 Degree Lighting: $143.50 - $161.50 FR HIPPING on orders over $75. FR GIFT ONLY AT LUMN: Use code ALANC to get a FR alance LD Task Lamp (retail value of $159.50) with qualifing $350+ dweLD or WAC Lighting purchase during the ummer ale. Limited time onl. FR VINTAG TRING LIGHT KIT: Use code TRING at checkout to get a FR Vintage tring Light Kit  ulrite (a $100 value) with qualifing $350 purchase during the ummer ale. Limited time onl. One per customer, while supplies last. 14W LDme xterminator II Track Light  WAC Lighting  elect items in stock, choose options to view or check availailit. Finish: Track Tpe: Light Temperature: eam pread: lack rushed Nickel White H-Track J-Track L-Track 2700K 2700K (90 CRI)3000K 3000K (90 CRI)3500K 4000K 20 Degree 40 Degree hown in rushed Nickel CUTOMIZAdd custom contact info, project, logo and more.CRATGenerate PDF pec heet to save, print and share. Product Options Finish: lack, rushed Nickel, White Track Tpe: H-Track, J-Track, L-Track Light Temperature: 2700K, 2700K (90 CRI), 3000K, 3000K (90 CRI), 3500K, 4000K eam pread: 20 Degree, 40 Degree Details Designed in 2015 Material: Die-cast Aluminum uperior illumination with compact design 355° horizontal rotation 180° vertical aiming Accomodates one lens accessor and one glare control accessor Rated Life: 100,000 hours Dimming: 100% - 5% Dimmale when used with lectronic low voltage (LV) Dimmer dimmers(not included) Title 24 compliant TL Listed Warrant: 5 Years Functional, 2 Years Finish Made In China Dimensions Fixture Width 3.75", Depth 2": Maximum Hanging Length 4.5": Lighting 2700K Option: 14 Watt (852 Lumens) 12 Volt Integrated LD: CRI: 85 2700K Option: 14 Watt (860 Lumens) 12 Volt Integrated LD: CRI: 85 2700K (90 CRI) Option: 14 Watt (624 Lumens) 12 Volt Integrated LD: CRI: 90 2700K (90 CRI) Option: 14 Watt (627 Lumens) 12 Volt Integrated LD: CRI: 90 3000K Option: 14 Watt (857 Lumens) 12 Volt Integrated LD: CRI: 85 3000K Option: 14 Watt (872 Lumens) 12 Volt Integrated LD: CRI: 85 3000K (90 CRI) Option: 14 Watt (663 Lumens) 12 Volt Integrated LD: CRI: 90 3000K (90 CRI) Option: 14 Watt (677 Lumens) 12 Volt Integrated LD: CRI: 90 3500K Option: 14 Watt (912 Lumens) 12 Volt Integrated LD: CRI: 85 3500K Option: 14 Watt (917 Lumens) 12 Volt Integrated LD: CRI: 85 4000K Option: 14 Watt (965 Lumens) 12 Volt Integrated LD: CRI: 85 4000K Option: 14 Watt (980 Lumens) 12 Volt Integrated LD: CRI: 85 Additional Details Product URL: /14w-ledme-exterminator-ii-track-light--wac-lighting- WACP150353.html Rating: TL Listed hown in rushed Nickel Notes:           14W LDme xterminator II Track Light  WAC Lighting Call Us 877.445.4486 Product ID: WACP150353 Prepared :Prepared for: Project: Room: Placement: Approval: Created June 3rd, 2017 C Spec-Sheet-LY4RCS-30K C Spec-Sheet-LY4RCS-30K 1 compliance-report-signed_2_060317 2 compliance-report-signed_2_060317 A 14W LEDme Exterminator II Track Light by WAC Lighting at Lumens II I Received 6/13/17 06/14/ 2 0 1 7 nickt DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO415 E. HYMAN AVE.MTE 1616 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED FLOOR PLANS 3.2 01/10/2017SCHEMATIC DESIGN 02/15/2017PERMIT SET 6/6/2017CHANGE ORDER I 108 101 107 103 105 106 4 7.1 14'-11"51/2"9'-51/2"81/2"14'-4"51/2"25'-61/16"51/2"81/2"9'-11"51/2"11/2"51/2"7'-93/8"51/2"9'-8"51/2"10'-1111/16"51/2"3'-61/2"51/2"4'-5"20'-5" 4'-11"7'-6"7'-8"4'-9" 8'-73/4"51/2"2'-0"3'-93/4"9'-11"3'-05/8"6'-0" 115/8"9'-6"10'-7"2'-11/4" 1'-113/4"2'-0"3'-11/4" 14.2 NEW DOOR TO EXIST. DECK; EXIST. DOOR LOCATION TO BE FILLED; LOCATION TO BE V.I.F. BY G.C.; SEE DETAIL 5 ON SHEET 7.1 FOR HEADER ALIGN W/ DOOR 108 TYPICAL WALL CONNECTION 6' W x 4'H TRANSLUCENT WINDOW EXIST. STAIR DOWN TO 3RD FLOOR; SEE SITE PLAN FOR STAIR RELATIONSHIP TO BUILDING AREA OUTSIDE OF WORK SCOPE EXIST. DECK W2TYP. U.N.O. W1 EXIST. FLOOR TO REMAIN W3 CONFERENCEROOM REF. WAITING KITCHEN ADA BATHROOM OFFICE #1 OFFICE #2 STORAGE CL CL CL CL CL CL CL CL EGRESS PATH = 57'1 1 CC CC CC C C C C C C C C CC C C C C C C A A A A A A A A A A AREA OUTSIDE OF WORK SCOPE EXIST. DECK EXIST. ROOF STRUCTURE ABOVE CEILING TO REMAIN; SEE ASSEMBLY R1 C CONFERENCEROOM WAITING KITCHEN ADA BATHROOM OFFICE #1 OFFICE #2 STORAGE 105 63/4"3'-0"3'-0"4'-0"3'-0"4'-6"2'-0"3'-1" R-63 SPRAY-IN RIGID CLOSED-CELL INSULATION (ACTS AS VAPOR BARRIER) SEE INTERIOR ELEVATIONS FOR C.T. HEIGHT CLEAR FLOOR SPACE FOR SHOWER ACCESS LINE OF SINK CLEARANCE DOOR MANEUVER CLEARANCE SEE INTERIOR ELEVATIONS FOR GRAB BAR AND CONTROL DIMS AND ACCESSORY LOCATIONS 30"x48"CLEAR FLOOR SPACE 0 2'4'8'SCALE: 1/4" = 1'-0"2 MAIN LEVEL PLAN NEW 0 2'4'8'SCALE: 1/4" = 1'-0"2 MAIN LEVEL R.C.P. 0 1'2'4'SCALE: 1/2" = 1'-0"2 ADA COMPLIANCE PLAN I Received 6/13/17 06/14/ 2 0 1 7 nickt DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO415 E. HYMAN AVE.MTE 1616 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED ASSEMBLIES & DETAILS 7.1 01/10/2017SCHEMATIC DESIGN 02/15/2017PERMIT SET 6/6/2017CHANGE ORDER I 3 3/8"3 3/8"1"3/8"7/8" 5/8"5 1/2"5/8" 1"7/8"3/8"3 3/8"3 3/8"3/8" 1"7/8"3 3/8"3/8" 1"7/8"1/8" x 3" ROLLED STEELBASEBOARD BEYOND 5/8" GYP. BOARD TYP.ENGINEERED 2 x 6 STUD TYP. 3/8" CLEAR GLASS SILICON BEAD 1/8" STEEL CHANNEL TYP. ENGINEERED 2 x 6 STUD TYP. 1/8" STEEL CHANNEL TYP. SILICON BEAD 3/8" CLEAR GLASS BATT INSULATION TYP. ENGINEERED 2 x 4 STUD TYP. 1/8" x 3" ROLLED STEELBASEBOARD BEYOND 5/8" GYP. BOARD TYP. ENGINEERED 2 x 6 STUD TYP.3/8" CLEAR TEMPERED GLASS SILICON BEAD 1/8" STEEL CHANNEL TYP. ENGINEERED 2 x 6 STUD TYP. ENGINEERED 2 x 4 STUD TYP. BATT INSULATION TYP. 1/8" x 3" ROLLED STEELBASEBOARD BEYONDMcFeelys washer head combodrive screws 5/8" GYP. BOARD TYP. ENGINEERED 2 x 6 STUD TYP.3/8" CLEAR TEMPERED GLASS SILICON BEAD 1/8" STEEL CHANNEL TYP. ENGINEERED 2 x 6 STUD TYP. ENGINEERED 2 x 4 STUD TYP. BATT INSULATION TYP. 1 3" = 1'-0" 3" = 1'-0"2 GLASS FRAME DETAIL CL GLASS FRAME DETAIL CL CL 3" = 1'-0"3 GLASS FRAME DETAIL CL DOOR HEADER IN EXIST. CMW WALL53" = 1'-0" 3" = 1'-0"4 1 HOUR FIRE RATED WALL CONNECTION1 HOUR FIRE RATED WALL CONNECTION 8" NOMINAL WIDTH EXIST. CMU EXTERIOR BEARING WALL EXIST. WALL FURRING NEW BLOCKING FOR FIRE RATING NEW TYPE X 5/8" SHEET ROCK BACKER FOR FIRE RATING WOOD TRIM TO MATCH EXIST. EXIST. WALL FURRING 8" NOMINAL WIDTH EXIST. CMU EXTERIOR BEARING WALL WT 6 x 15 STEEL HEADER; GROUTED W/ 6" BACKSPAN BEYEOND DOOR 5/8"SEE PLAN 5/8" 5/8"SEE PLAN 5/8" 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH - SEE SCHEDULE WALL FRAMING W/ BLOCKING AS REQUIRED SOUND ATTENUATING INSULATION - REFER TO SPECS 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH - SEE SCHEDULE 5/8" TYP. X GYPSUM WALL BOARD SEE INTERIOR SCHEDULE FOR FINISH WALL FRAMING W/ BLOCKING AS REQUIRED SOUND ATTENUATING INSULATION - REFER TO SPECS 5/8" TYP. X GYPSUM WALL BOARD SEE INTERIOR SCHEDULE FOR FINISH; SEE DETAIL 4 ON SHEET 7.1 FOR PLAN DETAIL WALL FRAMING W/ BLOCKING AS REQUIRED SOUND ATTENUATING INSULATION - REFER TO SPECS 8" NOMINAL WIDTH EXIST. CMU EXTERIOR BEARING WALL 1 ½" = 1'-0"W3 1 HOUR RATED NEW WALL @ EXIST. CMU (TYPICAL) 1 ½" = 1'-0" INTERIOR WALL (TYPICAL)W1 GL GL 1 ½" = 1'-0" 1 HOUR FIRE RATED INTERIOR WALL (TYPICAL)W2 GL UL SYSTEM DESIGN NO. U314 UL SYSTEM DESIGN NO. U314 EXIST. RAFTER TO REMAIN EXIST. ROOF DECK TO REMAIN NEW RECESSED CAN; SEE SPECS. SQUARLINE METAL ACCOUSTIC CEILING PANEL; 24X24 EXIST. ROOF MENBRANE AND RIGID INSULATION TO REMAIN FULL COAT, COMPLETE COVERAGE FORCEFIELD FIREGAURD E-84 INTUMESCENT PAINT WIRE TIE FOR DROP PANEL PER MANUF. REC. 1 HOUR RATED CEILING ASSEMBLYR11 ½" = 1'-0" UL TEST NO. U263, SEE ASSEMBLY FC-8 ON SHEET 7.2 ALL EXIST. EXTERIOR WALL CAVITIES WILL BE FILL W/ INSULATION IF EXPOSED. I Received 6/13/17 06/14/ 2 0 1 7 nickt