Series TY-FRL – 5.6 K-factor Horizontal Sidewall Sprinkler Quick Response, Standard Coverage Worldwide Contacts www.tyco-fire.com Page 1 of 4 DECEMBER 2016 TFP140 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. General Description TYCO Series TY-FRL 5.6K Horizon- tal Sidewall Sprinklers (HSW), Quick Response, Standard Coverage are sol- der-type spray sprinklers designed for use in light and ordinary hazard com- mercial occupancies such as banks, hotels, shopping malls, offices, etc. They are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Horizontal sidewall sprinklers are commonly used instead of pendent or upright sprin- klers due to aesthetics or building con- struction considerations, where piping across the ceiling is not desirable. NOTICE The Series TY-FRL Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Numbers (SINs) TY3321 – HSW 5.6K, 1/2”NPT TY3321 is a re-designation for Star SIN S1878 and Gem SIN G8946. Technical Data Approvals UL and C-UL Listed FM and NYC Approved (Refer to Table A for complete approval information.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=5.6 gpm/psi½ (80,6 lpm/bar½) Temperature Ratings Refer to Table A Finishes Refer to Table A Physical Characteristics Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Strut. . . . . . . . . . . . . . . . . . . . . . . . . . . . . MONEL Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Hook . . . . . . . . . . . . . . . . . . . . . . . . . . . . MONEL Link Assembly . . . . . . . . . . . . . . . . . . . . . . Nickel Ejection Spring . . . . . . . . . . . . . . . . . . INCONEL Button . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TEFLON Operation The fusible link (heat collector) assem- bly is comprised of two halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, allowing the sprin- kler to operate. Design Criteria TYCO Series TY-FRL 5.6K HSW Sprin- klers, Quick Response, Standard Coverage are intended for fire pro- tection systems designed in accor- dance with the standard installation rules recognized by the applicable listing or approval agency (e.g., UL Listing is based on NFPA 13 require- ments); however, the minimum dis- tance between sprinklers to prevent cold soldering is 8 feet (2,4 m). The Series TY-FRL HSW Sprinklers must be installed with a deflector- to-ceiling distance of 4 to 6 inches (100 to 150 mm). To meet this require- ment the centerline of the sprinkler waterway must be located 4-5/16 to 6-5/16 inches (110 to 160 mm) below the ceiling. Installation of the Series TY-FRL HSW Sprinklers in recessed escutcheons will void all manufac- turer’s warranties, as well as possibly void the sprinkler’s approvals and/or listings. 9/26/17 TFP140 Page 2 of 4 Installation TYCO Series TY-FRL 5.6K HSW Sprin- klers, Quick Response, Standard Cov- erage must be installed in accordance with this section. General Instructions A leak-tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 lbs-ft. (9,5 to 19,0 Nm). A maximum of 21 lbs-ft. (28,5 Nm) of torque may be used to install sprin- klers with 1/2 NPT connections. Higher levels of torque may distort the sprin- kler inlet and cause leakage or impair- ment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Horizontal Sidewall SprinklersNote: The Series TY-FRL HSW Sprin- klers must be installed with their cen- terline of waterway parallel to the ceiling and perpendicular to the back wall surface. The word “TOP” on the deflector must face upwards toward the ceiling. Step 1. After installing an escutcheon (as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 2). With reference to Figure 1, the W-Type 9 Sprinkler Wrench is to be applied to the wrench area. K FACTOR SPRINKLER TYPE TEMPERATURE RATING FRAME COLOR CODE SPRINKLER FINISH NATURAL BRASS CHROME PLATED 5.6 1/2” NPT HORIZONTAL SIDEWALL (TY3321) 165°F (74°C)Unpainted 1, 2, 3, 4 212°F (100°C)White Notes: 1. UL Listed for light or ordinary hazard occupancies as Quick Response sprinklers 2. C-UL Listed for light or ordinary hazard occupancies as Quick Response sprinklers 3. FM Approved for light hazard occupancies Quick Response sprinklers 4. Approved by the City of New York under MEA 112-04-E WRENCH RECESS 2 1 4 7 63 5 8 ISO 7-1 can be provided on Pipe thread connections per Temperature rating is indicatedButton Strut Deector Frame Assembly Link Hook Ejection Spring Seal on Deector special request * ** * *** WATERWAY OF SPRINKLER CENTERLINE SURFACE PLATE SEATING WALLTOP (15,9 mm) 5/8" NOMINAL 5/16" (7,9 mm) DEFLECTOR BOSS (41,3 mm) DEFLECTOR 1-5/8" 3.5° 2-11/16" (68,3 mm) 7/16" (11,1 mm) NOMINAL MAKE-IN (50,8 mm) 2" WRENCH AREA 6 3 4 5 2 7 WRENCH FLANGES 1/2" NPT 8 1 - - - - -- - - FIGURE 1 QUICK RESPONSE SERIES TY-FRL (TY3321) HORIZONTAL SIDEWALL SPRINKLER 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 2 W-TYPE 9 SPRINKLER WRENCH TABLE A LABORATORY LISTINGS AND APPROVALS 9/26/17 TFP140 Page 3 of 4 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRL 5.6K Quick Response Horizontal Sidewall Sprin- klers, SIN TY3321, (specify) temperature rating, (specify) finish, P/N (specify from Table B) Sprinkler Wrench Specify: W-Type 9 Sprinkler Wrench, P/N 56-000-1-849 Care and Maintenance TYCO Series TY-FRL 5.6K HSW Sprin- klers, Quick Response, Standard Cov- erage must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi-fied or over-heated sprinklers must be replaced. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re placed. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. P/N 58 — XXX — X — XXX SPRINKLER FINISH 1 NATURAL BRASS 9 CHROME PLATED SIN 946 5.6K HSW (1/2” NPT)TY3321 TEMPERATURE RATING 165 165°F (74°C) 212 212°F (100°C) TABLE B SERIES TY-FRL HORIZONTAL SIDEWALL SPRINKLERS, QUICK RESPONSE PART NUMBER SELECTION 9/26/17 Series TY-FRL — 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage Page 1 of 6 APRIL 2017 TFP130 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com NOTICE The Series TY-FRL Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Numbers TY1121 . . . . . . . . . . . . .Upright 2 .8K, 1/2”NPT TY1221 . . . . . . . . . . . . .Pendent 2 .8K, 1/2”NPT TY3121 . . . . . . . . . . . . . .Upright 5 .6K, 1/2”NPT TY3221 . . . . . . . . . . . . .Pendent 5 .6K, 1/2”NPT TY4121 . . . . . . . . . . . . .Upright 8 .0K, 3/4”NPT TY4221 . . . . . . . . . . . . .Pendent 8 .0K, 3/4”NPT TY1121 is a redesignation for S1879 and G8973. TY1221 is a redesignation for S1880 and G8971. TY3121 is a redesignation for S1864 and G8974. TY3221 is a redesignation for S1865 and G8972. TY4121 is a redesignation for S1866 and G8174. TY4221 is a redesignation for S1867 and G8172. General Description The TYCO Series TY-FRL, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, solder type spray sprinklers designed for use in light and ordinary hazard commercial occupancies such as banks, hotels, shopping malls, schools, hospitals, etc. The recessed version of the 2.8 and 5.6 K-factor, Series TY-FRL Pendent Sprin- kler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 20 (1/2 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. An intermediate level version of the 5.6 and 8.0 K-factor, Series TY-FRL Pendent Sprinkler can be obtained by utilizing the Series TY-FRL Pendent Sprinkler in combination with the Model S4 Shield. 9/26/17 TFP130 Page 2 of 6 * *** *** * * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 7/16" (11,1 mm) NOMINAL MAKE-IN WRENCH FLANGES ESCUTCHEON PLATE SEATING SURFACE WRENCH AREA STYLE 20 RECESSED ESCUTCHEON Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. DEFLECTOR 2-7/8" (73,0 mm) DIA. 5 6 3 2 4 7 8 1 1 2 Deector Strut Frame - -Link Assembly Seal Button-7 1/2" NPT 3 - 5 - Hook4- 6 -Ejection Spring -8 DEFLECTOR 2-11/16" (68,3 mm) 2" (50,8 mm) 2-11/16" (68,3 mm) * *** *** * * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 7/16" (11,1 mm) NOMINAL MAKE-IN WRENCH FLANGES ESCUTCHEON PLATE SEATING SURFACE WRENCH AREA STYLE 20 RECESSED ESCUTCHEON Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. DEFLECTOR 2-7/8" (73,0 mm) DIA. 5 6 9 3 2 4 7 8 1 1 2 Deector Strut Frame- -Link Assembly Seal 9 -Bushing Button-7 1/2" NPT 3 - 5 - Hook4-6 -Ejection Spring -8 DEFLECTOR 2-11/16" (68,3 mm) 2" (50,8 mm) 2-11/16" (68,3 mm) FIGURE 1 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TY1121) AND PENDENT (TY1221) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT FIGURE 2 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TY3121) AND PENDENT (TY3221) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 9/26/17 TFP130 Page 3 of 6 Technical Data Approvals UL and C-UL Listed FM and NYC Approved Refer to Table A for complete approval information Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/psi1/2 (40,3 LPM/bar1/2) K = 5.6 GPM/psi1/2 (80,6 LPM/bar1/2) K = 8.0 GPM/psi1/2 (115,2 LPM/bar1/2) Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Strut. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monel Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Hook . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monel Link Assembly . . . . . . . . . . . . . . . . . . . . . . Nickel Ejection Spring . . . . . . . . . . . . . . . . . . . . Inconel Button . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TEFLON Bushing (2.8K only) . . . . . . . . . . . . . . . . . . .Brass Operation The fusible link (heat collector) assem- bly is comprised of two halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, allowing the sprin- kler to operate. Design Criteria The TYCO Series TY-FRL Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM’s Loss Pre- vention Data Sheets). Only the Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRL Sprinklers must be installed in accordance with this section. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft./lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft./lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-FRL Pendent and Upright Sprinkler Installation The Series TY-FRL Pendent and Upright Sprinklers must be installed in accordance with this section. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 6). With reference to Figures 1, 2, and 3, the W-Type 9 Sprinkler Wrench is to be applied to the wrench area. * ** * * * *** UPRIGHT PENDENT CROSS SECTION WRENCH AREA Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. 1 2 Deector Strut Frame- - Link Assembly Seal Button-7 WRENCH FLANGES 3 - 5 - Hook4- 6 -Ejection Spring -8 DEFLECTOR CEILING PLATE SEATING SURFACE 2-3/16" (55,6 mm) DEFLECTOR 2-13/16" (71,4 mm) 1/2" (12,7 mm) NOMINAL MAKE-IN 2-15/16" (74,6 mm) 5 6 2 4 3 7 8 1 3/4" NPT FIGURE 3 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TY4121) AND PENDENT (TY4221) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT 9/26/17 TFP130 Page 4 of 6 Series TY-FRL Recessed Pendent Sprinkler Installation The Series TY-FRL Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 20 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 12 Recessed Sprinkler Wrench (Ref. Figure 7). With reference to Figure 1, or 2, the W-Type 12 Recessed Sprinkler Wrench is to be applied to the sprinkler wrenching flanges. Step C. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Escutch- eon over the Series TY-FRL Sprinkler and push the Escutcheon over the Mounting Plate until its flange comes in contact with the ceiling. SPRINKLER FINISH K TYPE TEMP. RATING FRAME COLOR CODE NATURAL BRASS CHROME PLATED 2.8 1/2” NPT PENDENT (TY1221) 165°F (74°C)Unpainted 1, 2, 5 212°F (100°C)White UPRIGHT (TY1121) 165°F (74°C)Unpainted 212°F (100°C)White RECESSED PENDENT (TY1221 w/Style 20) 165°F (74°C)Unpainted 212°F (100°C)White 5.6 1/2” NPT PENDENT (TY3221) 165°F (74°C)Unpainted 1, 2, 3, 4, 5 212°F (100°C)White 1, 2, 3, 5 UPRIGHT (TY3121) 165°F (74°C)Unpainted 1, 2, 3, 4, 5 212°F (100°C)White 1, 2, 3, 5 RECESSED PENDENT (TY3221 w/Style 20) 165°F (74°C)Unpainted 1, 2, 5212°F (100°C)White 8.0 3/4” NPT PENDENT (TY4221) 165°F (74°C)Unpainted 1, 2, 3, 5212°F (100°C)White UPRIGHT (TY4121) 165°F (74°C)Unpainted 212°F (100°C)White NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/03) as Quick Response Sprinklers. 5. Approved by the City of New York under MEA 112-04-E. TABLE A LABORATORY LISTINGS AND APPROVALS 9/26/17 TFP130 Page 5 of 6 Care and Maintenance The TYCO Series TY-FRL Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied or over-heated sprinklers must be replaced. Care must be exercised to avoid dam-age to the sprinklers -before, during, and after installation. Sprin- klers dam-aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. CLOSURE MOUNTING SURFACE FACE OF SPRINKLER FITTING 1/2±1/8" (12,7±3,2 mm)1/4" (6,4 mm) TY-FRL 2-1/4" DIA. (57,2 mm) 1-1/2" (38,1 mm) 1-3/4" (44,5 mm) MOUNTING PLATE 1/8" (3,2 mm) 2-7/8" DIA. (73,0 mm) 1/2" (12,7 mm) CLOSURE MOUNTING SURFACE FACE OF SPRINKLER FITTING 1/2±1/8" (12,7±3,2 mm)1/4" (6,4 mm) TY-FRL 2-1/4" DIA. (57,2 mm) 1-1/2" (38,1 mm) 1-3/4" (44,5 mm) MOUNTING PLATE 1/8" (3,2 mm) 2-7/8" DIA. (73,0 mm) 1/2" (12,7 mm) WRENCH RECESS PUSH WRENCH UP TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA WRENCH RECESS FIGURE 4 SERIES TY-FRL (TY1221) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT FIGURE 5 SERIES TY-FRL (TY3221) RECESSED PENDENT SPRINKLER ASSEMBLY WITH TW0-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT FIGURE 6 W-TYPE 9 SPRINKLER WRENCH FIGURE 7 W-TYPE 12 RECESSED SPRINKLER WRENCH 9/26/17 GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP130 Page 6 of 6 Copyright © 2017 Tyco Fire Products, LP. All rights reserved. TEFLON is a registered trademark of DuPont. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRL (specify SIN), (specify K-factor), (specify Upright, Pendent, or Recessed Pendent) Sprin- kler Quick Response, (specify) temper-ature rating, (specify type of finish), P/N (specify from Table B) Recessed Escutcheon Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 9 Sprinkler Wrench, P/N 56-000-1-849 Specify: W-Type 12 Sprinkler Wrench, P/N 56-798-1-001 SIN 973 2.8K UPRIGHT (1/2”NPT)TY1121 981 2.8K PENDENT (1/2”NPT)TY1221 974 5.6K UPRIGHT (1/2”NPT)TY3121 982 5.6K PENDENT (1/2”NPT)TY3221 174 8.0K UPRIGHT (3/4”NPT)TY4121 172 8.0K PENDENT (3/4”NPT)TY4221 SPRINKLER 1 NATURAL BRASS 9 CHROME PLATED TEMPERATURE RATING 165 165°F (74°C) 212 212°F (100°C) P/N 58 - XXX - X - XXX TABLE B SERIES TY-FRL PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION 9/26/17 Schedule 10 and Schedule 40 A company 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail: bmtinfo@bullmoosetube.com For additional information, contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 2/07 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Bull Moose Tube’s Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. Schedule 10 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Nominal Wall (in) Weight/Ft Bundle Size 1 1-1/4 1-1/2 2 2-1/2 3 4 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.097 1.442 1.682 2.157 2.635 3.260 4.260 0.109 0.109 0.109 0.109 0.120 0.120 0.120 1.40 lbs/ft 1.81 lbs/ft 2.08 lbs/ft 2.64 lbs/ft 3.53 lbs/ft 4.33 lbs/ft 5.62 lbs/ft 91 61 61 37 30 19 19 Schedule 40 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Nominal Wall (in) Weight/Ft Bundle Size 1 1-1/4 1-1/2 2 2-1/2 3 4 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.049 1.380 1.610 2.067 2.468 3.068 4.026 0.133 0.140 0.145 0.154 0.203 0.216 0.237 1.68 lbs/ft 2.27 lbs/ft 2.72 lbs/ft 3.65 lbs/ft 5.79 lbs/ft 7.58 lbs/ft 10.79 lbs/ft 70 51 44 30 30 19 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer’s instructions for the specific fitting used. 9/26/17 9/26/17 Features The Gruvlok®Fire-Rite™short pattern fitting system incorporates 90 degree elbows and tees in 2" to 8" size ranges. Fire-Rite™fittings are manufactured at Anvil International’s Columbia, PA ISO 9002 facility. Fittings are painted to industry specification and are available galvanized for more corrosive environments. Fire-Rite™fittings are CAD designed for use with Gruvlok®Fire Protection products. Fire-Rite™fittings are cast Ductile Iron conforming to ASTM A536, Grade 65-45-12. www.anvilintl.comwww.anvilintl.com Description Data Sheet 36 Fire-Rite™Short Pattern Fire Protection Products •CAD designed increased internal diam- eters provide superior flow capability •300 PSI rating in conjunction with Gruvlok®Rigidlite®7400 couplings — Key for fire protection systems using secondary pressure pumps •Made in the USA •ISO 9002 Certified Manufacturing •UL/ULC Listed and FM Approved •Fire-Rite™– Light Weight – Heavy Value! ® APPROVED 9/26/17 C TO E C TO E C TO E Approx. Nominal Center Weight Size to End Each Inches Inches Lbs. DN(mm) mm kg 22 3/4 1.7 50 70 0.8 2 1/2 3 2.6 65 76 1.2 33 3/8 3.5 80 86 1.6 446.5 100 102 3.0 65 1/2 14.8 150 140 6.7 86 7/8 25.6 200 175 11.6 Figure 7450 90o Elbow Approx. Nominal Center Weight Size to End Each Inches Inches Lbs. DN(mm) mm kg 22 3/4 2.5 50 70 1.1 2 1/2 3 3.5 65 76 1.6 33 3/8 4.8 80 86 2.2 448.1 100 102 3.7 65 1/2 19.1 150 140 8.7 86 7/8 35.2 200 175 16.0 Figure 7460 Tee NEVADA: Sparks 89431, 1385 Greg Street, Phone: (775) 353-7366, Fax: (775) 331-2810 ILLINOIS: University Park 60466, 750 Central Ave., Phone: (708) 534-1414, Fax: (708) 534-5334 GEORGIA: Norcross 30071, 6344 Cash Court, Phone: (770) 662 8177, Fax: (770) 662-0284 PENNSYLVANIA: Bristol 19007, 2530 Pearl Buck Road, Phone: (215) 788-4056, Fax: (215) 788-4475 TEXAS: Grand Prairie 75050, 1313 Avenue R, Phone: (972) 343-9206, Fax: (972) 641-8946 ® #082/ Printed in USA / RPI / 5.03 / 5M/ ©2003DATA SHEET 36 www.anvilintl.comwww.anvilintl.com Fire-Rite™Short Pattern Fire Protection Products Figure 7450 90° Elbow Gruvlok short pattern fittings exceed the headloss requirements of NFPA 13. 18 16 14 12 10 8 6 4 2 0 5101520 Flow Rate (ft./sec.)Pressure Drop(ft. of Schedule 40 pipe)8 inch 6 inch 4 inch 3 inch 21/2 inch 2 inch For Fig. 7450 90° grooved end elbows use the value shown. For Fig. 7460 Tee branch use 21/2 times the value shown. For Fig. 7460 Tee run use the value shown. Short Pattern Fittings Pressure Drop 9/26/17 9/26/17 INDOOR/OUTDOOR Rev. 1 9/26/17 MODEL 1011 8/01 Chec k O u t O u r New AutoCAD Site! o The AGF Manufacturing Inc. Model 1011 Matches All The Features And Benefits Of Our Model 1000 by Providing Both The Test Function And The Express Drain Function In A Multistory Installation, With The Added Feature Of An Integral Model 7000 Pressure Relief Valve With Drainage Piping. o Available In A Full Range Of Sizes From 3/4 " To 2", NPT & BSPT, With All Specifiable Orifice Sizes 3/8 ", 7/16 ", 1/2 ", 17/32 ", 5/8 " (ELO), & 3/4 " (ESFR). o The Model 1011 Complies With The Requirements Of NFPA 13, 13R, & 13D, Which Stipulate A Pressure Relief Valve Be Installed On All Gridded Systems And Downstream Of All Pressure Reducing Valves. o The Model 1011 Is A Single Handle Ball Valve That Is Lightweight And Compact, Which Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glass, And Is 300 PSI Rated. o The Included UL/FM Model 7000 Pressure Relief Valve Features A Flushing Handle And Is Factory Set At 175 PSI, Other Pressure Settings Are Also Available. o Designed To Relieve Excess System Pressure Caused By Surges Or Temperature Changes As Well As Solve The Difficult Problem Of Providing The Relief Valve With A Drainage-Piping Outlet. o The Unit Comes Shipped In A Semi-Assembled State With The Relief Valve And The Bypass Drain Ports Plugged. This Is Done To Ease Pressure Testing The System. 3/4 "1"11/4 "11/2 "2" 9/26/17 B C D E F G H 3/4"7 9/16"191.30mm 1 1/2"37.58mm 2 3/16"55.65mm 3 5/8"93.23mm 3 3/8"85.88mm 1 13/16"45.30mm 4 9/16"117.12mm 6 3/8"162.42mm 7 9/16"191.30mm 1 1/2"37.58mm 2 3/16"55.65mm 3 5/8"93.23mm 3 3/8"85.88mm 1 13/16"45.30mm 4 9/16"117.12mm 6 3/8"162.42mm1" 1 1/4" 1 1/2" 2" 7 15/16"201mm 1 11/16"42.70mm 2 9/16"65.36mm 4 1/4"108.36mm 3 5/16"82.84mm 1 15/16"50.89mm 5 9/16"141.39mm 5 1/2"192.28mm8 15/16"226.68mm 1 13/16"45.50mm 3 1/4"81.50mm 5 1/16"127mm 3 7/8"99.18mm 2 5/8"66.97mm 8 1/4"206.63mm 10 7/8"273.60mm 8 15/16"226.68mm 1 13/16"45.50mm 3 1/4"81.50mm 5 1/16"127mm 3 7/8"99.18mm 2 5/8"66.97mm 8 1/4"206.63mm 10 7/8"273.60mm AGF MANUFACTURING COMPANY 100 Quaker Lane Malvern, PA 19355 USA Telephone: (610) 240-4900 Fax: (610) 240-4906 www.testandrain.com *Available on 1 1/4" to 2" size units only. PLAN VIEW 9/26/17 -71- Size Range—3/8 thru 7/8 inch rod in 10 foot lengths. Material – Carbon Steel. Maximum Temperature—750°F. Finish— Plain. Order By—Figure number, rod diameter, and finish. Note—Available in Electro- Galvanized and HDG finish or Stainless Steel materials. Fig. 98 Rod Stiffener Size Range—Secures 3/8 thru 7/8 inch hanger rod. Material – Carbon Steel. Function—Secures channel to hanger rod for vertical seismic bracing. Finish—Electro Galvanized. Order By—Figure number. Note—Available in HDG finish or Stainless Steel materials. Fig. 99 All Thread Rod Cut To Length Fig. 100 All Thread Rod Full Lengths Size Range—3/8 thru 7/8 inch rod in 1 inch increments. Material – Carbon Steel. Maximum Temperature—750°F. Finish— Plain. Order By—Figure number, rod diameter, rod length, and finish. Note—Available in Electro-Galvanized and HDG finish or Stainless Steel materials. ROD SIZE 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 MAX. REC. LOAD LBS. FOR SERVICE TEMPS 650°F 750°F ROD SIZE APPROX. WEIGHT PER 100FT. 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1-1/4 8000 7140 360 1-1/2 11630 10370 510 MAX. REC. LOAD LBS. FOR SERVICE TEMPS 650°F 750°F 5/24/2001 9/26/17 Office/Manufacturing Facility •1375 Sampson Ave. •Corona, CA 92879 •Ph: 909.737.5599 •Fax: 909.737.0330 Customer Service •800.786.5266 www.tolco.com 22 wwwwww..ttoollccoo..ccoomm Revision 5/24/2001 ™ ®a brand of Fig. 2 — Adjustable Band Hanger Fig. 2NFPA — Adjustable Band Hanger with Reduced Rod Dimensions • Weights Pipe Max. Rec. Approx Wt./100 Size Rod Size ABC Load Lbs. Fig. 2 Fig. 2NFPA 21/2 1/2* 5 3/4 41/4 15/8 600 41 40 3 1/2* 6 4 1/8 11/4 600 45 43 31/2 1/2* 73/8 51/4 21/8 600 52 50 4 5/8* 7 3/8 515/8 1000 59 56 5 5/8** 9 6 1/8 21/4 1250 97 95 6 3/4** 9 3/8 61/2 17/8 1250 139 105 * 3/8" nut is used when NFPA rod sizing is requested. ** 1/2" nut is used when NFPA rod sizing is requested. Size Range — Size 21/2" thru 4" pipe. Material — Carbon Steel, Pre-Galvanized Function — Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish — Pre-Galvanized Note — Available in Stainless Steel materials. Order By — Figure number, pipe size and material 9/26/17 Page 4 Note: Screws must be installed with appropriate nut driver to comply with warranty WOOD — Sammys Item# Model Shk Lgth Shk Dia BoxQty Weight (per 100) Case Qty 20 GST.750 3/4 1/4 100 4.75 1000 21 GST100 1 1/4 100 5.00 1000 22 GST200 2 1/4 100 6.50 1000 23 GST300 3 1/4 100 7.50 1000 24 GST600 6 1/4 50 9.00 500 WOOD • 1/4" Rod (Vertical Mount) Use #14 NutDriver (Item#100) Approvals Item# Model Shk Lgth Shk Dia FM Test Load, lb. UL Test Loadlb. UL/FM Pipe Size Actual Pullout Box Qty 10 GST.75 3/4 1/4 564# -6 Ply 100 NFPA 11 GST10 1 1/4 210# -7/16 OSB 670# -3/4" Ply 100 UL•FM•NFPA 12 GST20 2 1/4 940# 850# 3/4-2 1/2 1760# - Fir 100 UL•NFPA 27 GST25-380 2 1/2 3/8 1500# 4 2113# -Fir 50 UL•FM•NFPA 13 GST30 3 1/4 1475# 1500# 3/4-4 2060# - Fir 100 NFPA 403 GST40 4 1/4 2180# -Fir 50 NFPA 14 GST60 6 1/4 2230# -Fir 50 WOOD • 3/8" Rod (Vertical Mount) Use #14 NutDriver (Item#100) Item# Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight (per 100) Case Qty 8GST2 2 1/4 1760# -Fir 50 7.00 500 06 GST2.5-380 2 1/2 3/8 2113# -Fir 50 10.00 500 15 GST3 3 1/4 2275# -Fir 50 10.50 500 16 GST4 4 1/4 2180# -Fir 50 10.60 500 17 GST6 6 1/4 2230# -Fir 50 10.95 500 WOOD • 1/2" Rod (Vertical Mount) Use #14SWNutDriver (Item#101) qqqqq Wood Flooring Wood Joist rrrrrDouble Sheetrock Ceiling qqqqq Minimum 2” imbedment into base material for NFPA 13 compliance Not less than 2” nominal width (1 1/2”)Not less than3” nominal thickness (2 1/2”)(depth or side of vertical member)For vertical use. Install in center of lower face. Installation per NFPA 13 Consult truss manufacturer for recommended installation point. TJI Joist / Truss #14 (Item #100-black) Sammys 1/4”, 3/8” rod #14SW (Item #101-red) Sidewinders & Sammys 1/2” rod UL Listings and CAD Drawings are available at www.SammySuperScrew.com * * *Pre-drilling may be required for items #27 and #06. Tools available on page 9. 9/26/17 Page 5Note: Screws must be installed with appropriate nut driver to comply with warranty WOOD —Sidewinders Item # Model Shk Lgth Shk Dia Actual Shear/Pullout BoxQty Weight (per 100) Case Qty 4016 SWG100 1 1/4 100 7.50 1000 300 SWG200 2 1/4 1725# -Fir 100 8.00 1000 WOOD • 1/4" Rod(Horizontal Mount) Use #14SWNutDriver (Item#101) Approvals Item # Model Shk Lgth Shk Dia UL Test Loadlb. UL/FM Pipe Size Actual Shear/Pullout BoxQty Weight (per 100) C 18 SWG10 1 1/4 100 6.00 UL•NFPA 19 SWG20 2 1/4 1250# 3 1725# -Fir 100 7.00 UL•NFPA 26 SWG25-380 2 1/2 3/8 1500# 4 2249# -Fir 50 10.25 25 SWG30 3 1/4 50 8.50 WOOD • 3/8" Rod (Horizontal Mount) Use #14SWNutDriver (Item#101) #14SW (Item #101-red) Sidewinders & Sammys 1/2” rod SHEETROCK — Toggle Item# Model Shk Lgth Shk Dia Actual Pullout Pkg Qty Weight (per 100) Case Qty 70 SST30 3 1/4 450# Lath & Plaster 404# 2 Layers 5/8 Rock 50 12.00 500 SHEETROCK • 3/8" Rod (Vertical Mount) Use #14 NutDriver (Item#100) Minimum 2 1/2” from bottom for branch lines. Minimum 3” from bottom for main lines. Exception: This requirement shall not apply to 2” or thicker nailing strips resting on top of steel beams. Not less than 2” nominal width (1 1/2”) up to 3 1/2” pipe; not less than 3” nominal width 4” & 5” pipe Installation per NFPA 13 Floor Joist rrrrr TJI Joist / Truss Consult truss manufacturer for recommended installation point. Item# Model Shk Lgth Shk Dia Actual Pullout BoxQty Weight (per 100) Case Qty 71 SST300 3 1/4 450# Lath & Plaster 404# 2 Layers5/8 Rock 50 12.00 500 SHEETROCK • 1/4" Rod (Vertical Mount) Use #14 NutDriver (Item#100) qqqqq Prestressed Concrete #14 (Item #100-black) Sammys 1/4”, 3/8” rod *Pre-drilling may be required for item #26. Tools available on page 9. * 9/26/17 Sprinkler Gauge Standard Features Design EN 837-1 & ASME B40.100 Sizes 4” (100 mm) Accuracy class ± 3/2/3% of span (ASME B40.100 Grade B) Ranges 0/80 psi, retard to 250 psi (air) 0/300 psi (water or air) Working Pressure Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating Temperature Ambient: -40°F to 140°F (-40°C to 60°C) Media: 140°F (+60°C) maximum Temperature Error Additional error when temperature changes from reference tem- perature of 68°F (20°C) +0.4% for every 18°F (10°C) rising or falling. Percentage of span. ©2008 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fppi.com Bourdon Tube Material: copper alloy C-type Pressure Connection Material: copper alloy 1/4“ NPT lower mount (LM) Movement Copper alloy Dial White aluminum with stop pin; black and red lettering Pointer Black aluminum Case Black polycarbonate Window Snap-in clear polycarbonate Approvals UL listed (UL-393) Factory Mutual Applications • Fire sprinkler systems • Suitable for all media that will not obstruct the pressure system or attack copper alloy parts Special Features • UL-listed (UL-393), United States and Canada • Factory Mutual (FM) approved • Reliable and economical Optional Extras (not all options are UL or FM approved) • Brass restrictor • Friction-fi t cover ring (requires steel case) • Glass window (requires steel case & friction ring) • Black-painted steel case • Stainless steel case • Special case colors • Nickel-plated connection • Custom dial layout • Special threaded connection • Custom dial layout • Other pressure scales available: bar, kPa, MPa, kg/cm2 and dual scales Size A B C E L T W Weight 4” mm 100 83.5 30 11.5 3.75 14 in 4.0 3.29 1.18 0.45 0.15 1/4” 0.55 0.35 lb. Dimensions 9/26/17 System Sensor WFDT Retard and WFDTNR Non-Retard T-Tap Waterflow Detectors are designed for primary signaling in residential systems and branch line signaling in larger systems. Both models fit any tee that has a 1″NPT branch, including: 1″, 11⁄4″and 11⁄2″NPT threaded ferrous and brass tees; 1″, 11⁄4″, 11⁄2″and 2″copper sweat tees; Central, Spears®, and Victaulic®brand 1″CPVC tees; and 11⁄2″polybuty- lene tees. Design. The design of the WFDT and WFDTNR makes them easy to install and simple to maintain. Either can be mounted in the vertical or horizontal posi- tion. Two conduit openings permit easy attachment to the local alarm system. The retard mechanism (Model WFDT only) and switch assemblies are field- replaceable. Features.Nine different flexible plastic paddles fit 1″, 11⁄4″, 11⁄2″and 2″tees. Sizes are marked clearly on the paddle for ease of installation. Plastic paddles slip over the actuating lever and are securely fastened with one screw. The handy depth gauge insures the proper installation depth and clearance of the detector to the tee. Construction.The WFDT and WFDTNR include a durable tamper resistant enclosure and rugged switch assembly. The long lasting covers completely enclose the electrical components to keep out dust and dirt. Improved self-guid- ing security screws and removal tools make detectors resistant to tampering and simplify field maintenance. Dual SPDT switches are enclosed in a durable termi- nal block for added strength. Sealed retard mechanism (Model WFDT) assures that the retard is not contami- nated by dust and dirt when the cover is removed Visual Switch Activation (Model WFDT) permits installer to accurately set the retard even under extremely noisy conditions 100% Synchronization activates both alarm panel and local bell simultaneously Accommodates up to 12 AWG wire Models Available WFDT Waterflow Detector WFDTA Waterflow Detector (ULC/Canadian) WFDTNR Waterflow Detector (non-retard) Replacement Parts A77-01-02 Terminal Block for WFDT A77-01-08 Terminal Block for WFDTNR A3008-00 Retard Mechanism PRK9 Paddle Kit 546-7000 Cover Tamper Switch Kit S07-66-02 Tamper Screws for Cover WFDW Cover Wrench WFDN4 NEMA-4 Gasket Kit C58-164-01 Metal Cover Product Overview WFDT Waterflow Detector T-Tap Waterflow Detector WFDTNR Waterflow Detector 9/26/17 System Sensor Sales and Service ©2000 System Sensor. The company reserves the right to change product specifications without notice. A05-195-06•8/00(10K)•#672 Spears®is a registered trademark of the Spears Manufacturing Company; Victaulic®is a registered trademark of Victaulic Company of America. Engineering Specifications Model shall be a WFDT or WFDTNR as manufactured by System Sensor. T-tap waterflow detectors shall be installed on a tee that has a 1″NPT branch including: 1″, 11⁄4″, or 11⁄2″threaded ferrous or brass tee; 1–2″copper sweat tees; Central, Spears®, and Victaulic®brand 1″CPVC tees; or 11⁄2″polybutylene tee as designated on the drawings and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate size, either a vertical or horizontal run at least 6″from any fittings or valves which may change water direction, flow rate, or pipe diameter or no closer than 24″from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 250 psi. The retard t-tap detector shall be a sealed mechanical pneumatic unit with visual indi- cation of actuation. The actuation mechanism shall include a polyethylene vane inserted through the tee fitting and connected by a mechanical linkage to the delay mechanism. The non-retard t-tap detec- tor shall respond with no time delay to waterflow in the specified direction and range. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances (one of which is a knockout type) for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. All detectors shall be listed by Underwriters Laboratories for indoor or outdoor use. Bki h f Ordering Information Model Number Description WFDT Water flow Detector, Fits 1″, 11⁄4″, 11⁄2″ferrous and brass threaded tees; 1″, 11⁄4″, 11⁄2″, 2″copper sweat tees; 1″CPVC tees;and 11⁄2″polybutylene tees WFDTNR Water flow Detector, non-retard, fits same tees as Model WFDT A77-01-02 Replacement Terminal Block for WFDT A77-01-08 Replacement Terminal Block for WFDTNR A3008-00 Replacement Retard Mechanism PRK9 Replacement Paddle Kit — 11 paddles for WFDT and WFDTNR (see WFDT for sizes) 546-7000 Cover Tamper Switch Kit for WFDT S07-66-02 Replacement Tamper Screws for Covers of WFDT, WFDTNR WFDW Replacement Tamper Proof Wrench for Cover of WFDT, WFDTNR WFDN4 NEMA-4 Gasket Kit C58-164-01 Replacement Metal Cover Static Pressure Rating 250 PSI Triggering Threshold Bandwidth (Flow Rate) 4 – 10 GPM Maximum Surge 18 FPS Compatible Tee Fittings Threaded ferrous and brass tees, copper sweat tees, CPVC tees, and polybutylene tees Contact Ratings Two sets of SPDT (Form C) 10.0 A @ 125/250 VAC 2.5 A @ 24 VDC Overall Dimensions, Installed WFDT: 4.5″H x 3.75″W x 6.7″L (11.4cm H x 9.5cm W x 17cm L) WFDTNR: 3.75″H x 3.25″W x 4.25″L (9.5cm H x 8.2cm x W x 10.8cm L) Conduit Entrances 2 openings for 1⁄2″conduit Operating Temperature Range 32°F – 120°F (0°C – 49°C) Cover Tamper Switch UL Models: optional P/N 546-7000 ULC/Canadian Models: factory installed Enclosure UL Indoor/Outdoor Rated Shipping Weight WFDT: 2.6 lbs. (1.2 kg.) WFDTNR: 1.5 lbs. (0.7 kg.) Service Use Automatic Sprinkler: NFPA 13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA 72 Warranty 3 years U.S. Patent Nos. 3,845,259; 4,782,333; 5,213,205 Top View Switch 1 CO M COM ABBA Switch 2 NOTE: C c w p o Electrical Connections for WFDT CONTACT RATINGS 125/250 VAC 24 VDC 10 AMPS 2.5 AMPS WFDTH BB COM COM WFDTH BB COM COM itiating d FACP End of line resistorTo nonsilenceable initiating zone of listed FACP Typical FACP Connection { B COM to power source compatible with bell local bell Typical Local Bell Connection To power source compatible with bell WFDTH Switch Assembly Common and B connections will close when vane is deflected, i.e., when water is flowing. Dual switches permit applications to be com- bined on a single detector. Break wire as shown for supervision of connec- tion. Do not allow stripped wire leads to extend beyond switch housing. Do Not loop wires. 40123 15 30 5 45 55 70 Dial setting Delay (seconds) 0 1234532 0 1 4 515304555 7 0 ONNUMBER DIAL TIME APPROXIMA TE DELAY(S E CONDS)Table of dial settings embossed here (see below) Delay adjustment dial 0 0 Delay Adjustment Dial General Specifications System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800-SENSOR2 Fx: 630/377-6495 Documents On Demand: 1-800-736-7672 x3 Web: www.systemsensor.com System Sensor in Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor in Europe Ph: + 44.1403.276500 Fx: + 44.1403.276501 System Sensor in China Ph: + 86.29.524.6253 Fx: + 86.29.524.6259 System Sensor in Singapore Ph: + 65.273.2230 Fx: + 65.273.2610 System Sensor in the Far East Ph: + 852.21919003 Fx: + 852.27366580 System Sensor in Australia Ph: + 613.54.281.142 Fx: + 613.54.281.172 System Sensor in India Ph: + 91.11.558.2119 Fx: + 91.11.567.6815 9/26/17