HomeMy WebLinkAboutFile Documents.415 E Hyman Ave.0087.2017 (15).ACBKRoaring Fork Condominium Association, Inc. c/o Eric Mangelsen P.O. Box 1708 Aspen, CO 81612 970.429.8255 City of Aspen c/o Community Development Department 130 S. Galena Street Aspen, CO 81611 RE: F&M Ventures proposed remodel of the Aspen Snowmass Sotheby's International Realty Offices 415 E Hyman, Aspen, CO 81611 Roaring Fork Condominiums—Units 14 and 15 Pitkin County Parcel ID: 273718216114 and 273718216115 Permit No.: 0087.2017.ACBK To Whom It May Concern: As you are aware, F&M Ventures has submitted a permit application (No. 0087.2017.ACBK) to the City of Aspen so as to move forward with a remodel of the Aspen Snowmass Sotheby's International Realty offices located at 415 E Hyman, Aspen, CO 81611, also known as Roaring Fork Condominiums—Units 14 and 15 and Pitkin County Parcel ID: 273718216114 and 273718216115. The Roaring Fork Condominium Association, Inc. has been asked to confirm its approval to the proposed ADA accessible lift to be installed per the plans and specifications attached hereto as Exhibit A. While the Association does not generally oppose the idea and concept of the installation of a lift, the Association does not grant unfettered approval for the same. Specifically, the Association hereby grants a tentative approval based on the plans as submitted and will grant its final approval after it receives, in writing: (1) a final statement of costs from F&M Ventures as related to the ADA lift (which the Association must approve); and (2) the power of final approval and veto power over the design and aesthetics of the ADA lift. Once these requirements have been met, the Association will provide its final approval to the City for this project. Finally, the tentative and future approvals by the Association are based on the understanding that any and all necessary work related to the ADA lift is covered under Permit No. 0087.2017.ACBK and that the Association will not be required to apply for any additional permits or approvals related to the ADA lift. If this is not the case, the Association does not grant any tentative approvals until such time as the Association has the ability to fully analyze and understand the requirements to which it may be obligated to comply. Should you have any questions or wish to discuss this matter further, please feel free to contact me, in my capacity as an Association Board member, as indicated above. Sincerely, Roaring Fork Condominium Association, Inc. Board of Directors Enc. Ec: F&M Ventures; Forum Phi 06511422.DOCX;1 STEVEN WILSON 402127STATEOFCOLO R A DOLI CE NSED AR C H ITECTDRAWING ISSUANCE INDEX ID NAME BUILDING PERMIT ISSUED DATE 9/7/17, 3:07 PM STRUCTURAL CONSULTANTS FIRE MEP COPYRIGHT CONTRACTOR 12/6/17 PROJECT NO: DRAWN BY: FORUM PHI LLC 415 E HYMAN ASPEN CO 81611 SOTHEBY'S ASPEN 715 West Main Street, Suite 204 Aspen, Colorado 81611 P: 970.279.4157 F: 866.770.5585 DATE OF PUBLICATION A-005 ACCESSIBILITY FLOOR PLAN Flame Out Fire Protection Inc 550 Holland Hills Rd Basalt, CO 81621 (970) 927-4933 spencer@flameoutfire.net Bighorn Consulting Engineers 569 S. Westgate Drive, Suite #1 Grand Junction, CO 81505 (970) 241-8709 blaine@bighorneng.com Albright & Associates 402 Park Ave, Unit E Basalt, CO 81623 (970) 927-4363 jack@albright-associates.com Sherlock Homes Construction PO Box 17118 Snowmass Village, CO 81615 (979) 923-1122 tsherlock@sherlockhomesaspen.com 12/6/17 KF CC 1706 PARCEL ID#273718216114, 273718216115 ZONE DISTRICT DW 2 2F 1'-10"2'-8"2'-0"2'-8"1'-10"2'-8"1'-6"2'-8"1'-10"2'-8"2'-0"2'-8"2'-8"1'-10"4'-0" 2'-8" 2'-8"2'-8"1'-0"5'-0"2'-8"2'-8"2'-8"3'-6"3'-10"4'-0"3'-0"3'-0"5'-0"5'-0"1'-0"2'-8"4'-0" 2'-8"2'-0"2'-8"1'-10"2'-8"2'-0" 2'-8"2'-0"2'-8"1'-10"2'-8"1'-6"1'-0"3'-0"1'-0"2'-8"2'-81/2"8'-113/4"7'-41/4"5'-21/4" PLATFORM PROJECTION 3'-01/2"PLATFORMUNFOLDED100'-0"100'-0" 100'-0" 100'-0" 100'-0" 96'-5 3/4" A A-301 A A-301 TV DISPLAYS T.O FINISHT.O ALLEY T.O FF T.O FF T.O FF 3 3 5 5 C C A A 5'-0"4'-0"31/2"2'-0"1 1 4 4 D D B B2'-8"5'-0"3'-6"4'-61/2"2'-10"9'-21/2"2'-101/2" 13'-71/4" 19'-51/2" E E 01 A-403 01 A-402 01 A-401 1'-0"2'-8"3'-93/4"7'-41/4"31/2"5'-3"2'-6"2'-0"2'-8"4'-0"1'-6"2'-8"2'-0"2'-8"5'-0"4'-0"5'-0" 5'-0"5'-0" 5'-0"5'-0"5'-0"5'-0" 5'-0" 5'-0"5'-0"5'-0" 4'-0" 4'-0"4'-0"4'-0"4'-0" 5'-0"7'-101/2"31/2"3'-6"43/4"8'-21/4"43/4"3'-6"31/2"7'-101/2"EQ 31/2"EQ2'-8"4'-0" 2'-8"1'-10" 2'-8"1'-10"3'-6"2'-8"1'-10"9'-31/2"31/2"9'-31/2"31/2"9'-31/2"6" 8'-31/2"31/2" 8'-31/2"31/2" 8'-31/2"31/2" 8'-7" 4'-1"14'-7" 6'-1"6"7'-01/4" B A-301 B A-301 EXISTING FIRE SEPARATION TO REMAIN EXISTING FIRE SEPARATION TO REMAIN EXISTING FIRE SEPARATION TO REMAIN EXISTING FIRE SEPARATION TO REMAIN FLIP DOOR DIRECTION NEW ACCESSIBILITY LIFT (REFER TO SPEC) EXISTING STANDPIPE WOOD TBD WOOD TBD TILE TBD WOOD TBD WOOD TBD MECH DN DN N0 2'4'8'SCALE: 1/4" = 1'-0" ACCESSIBILITY FLOOR PLAN STEVEN WILSON 402127STATEOFCOLO R A DOLI CE NSED AR C H ITECTDRAWING ISSUANCE INDEX ID NAME BUILDING PERMIT ISSUED DATE 9/7/17, 3:07 PM STRUCTURAL CONSULTANTS FIRE MEP COPYRIGHT CONTRACTOR 12/6/17 PROJECT NO: DRAWN BY: FORUM PHI LLC 415 E HYMAN ASPEN CO 81611 SOTHEBY'S ASPEN 715 West Main Street, Suite 204 Aspen, Colorado 81611 P: 970.279.4157 F: 866.770.5585 DATE OF PUBLICATION A-101 PROPOSED FIRST FLOOR Flame Out Fire Protection Inc 550 Holland Hills Rd Basalt, CO 81621 (970) 927-4933 spencer@flameoutfire.net Bighorn Consulting Engineers 569 S. Westgate Drive, Suite #1 Grand Junction, CO 81505 (970) 241-8709 blaine@bighorneng.com Albright & Associates 402 Park Ave, Unit E Basalt, CO 81623 (970) 927-4363 jack@albright-associates.com Sherlock Homes Construction PO Box 17118 Snowmass Village, CO 81615 (979) 923-1122 tsherlock@sherlockhomesaspen.com 12/6/17 KF CC 1706 PARCEL ID#273718216114, 273718216115 ZONE DISTRICT DW 2 2 115 A 114 AF 2'-81/2"8'-113/4"7'-41/4"5'-21/4" PLATFORM PROJECTION 3'-01/2"PLATFORMUNFOLDED100'-0" 100'-0" 100'-0" 96'-5 3/4" A A-301 A A-301 T.O FF T.O FF T.O FF OPEN OFFICES 113 OPEN OFFICE 103 PRIVATE OFFICE 107 PRIVATE OFFICE 106 PRIVATE OFFICE 105 PRIVATE OFFICE 110 PRIVATE OFFICE 111 PRIVATE OFFICE 108 CONFERENCE ROOM 104 STAFF DESKS 102 SHOWROOM 101 COPY CENTER 112 PRIVATE OFFICE 114 PRIVATE OFFICE 115 KITCHEN 116 PRIVATE OFFICE 109 3 3 5 5 C C A A 103 A 113 B 116 A 106 A 107 A 108 A 105 A 109 A 110 A 111 A 104 A 31/2"2'-0"1 1 4 4 D D B B W-1 W-1 W-1 W-2 W-2 W-2 STORAGE 4'-61/2"2'-10"9'-21/2"2'-101/2" 13'-71/4" 19'-51/2" E E 01 A-403 01 A-402 01 A-401 3'-93/4"7'-41/4"31/2"5'-3"2'-6"7'-101/2"31/2"3'-6"43/4"8'-21/4"43/4"3'-6"31/2"7'-101/2"EQ 31/2"EQ 9'-35/8"31/2"9'-31/2"31/2"9'-35/8"6" 8'-31/2"31/2" 8'-31/2"31/2" 8'-31/2"31/2" 8'-7" 4'-1"14'-7" 6'-1"6"7'-01/4" B A-301 B A-301 EXISTING FIRE SEPARATION TO REMAIN EXISTING FIRE SEPARATION TO REMAIN EXISTING FIRE SEPARATION TO REMAIN EXISTING FIRE SEPARATION TO REMAIN FLIP DOOR DIRECTION NEW ACCESSIBILITY LIFT (REFER TO SPEC) EXISTING STANDPIPE WOOD TBD WOOD TBD TILE TBD WOOD TBD WOOD TBD MECH EXISTING ELEVATOR COMMON SPACE EXISTING TOILET ROOMS NOT IN SCOPE OF WORK DN DN EXISTING TO REMAIN TO BE DEMOLISHED WALL LEGEND EXISTING TO REMAIN NEW WALL N0 2'4'8'SCALE: 1/4" = 1'-0" PROPOSED FIRST FLOOR STEVEN WILSON 402127STATEOFCOLO R A DOLI CE NSED AR C H ITECTDRAWING ISSUANCE INDEX ID NAME BUILDING PERMIT ISSUED DATE 9/7/17, 3:07 PM STRUCTURAL CONSULTANTS FIRE MEP COPYRIGHT CONTRACTOR 12/6/17 PROJECT NO: DRAWN BY: FORUM PHI LLC 415 E HYMAN ASPEN CO 81611 SOTHEBY'S ASPEN 715 West Main Street, Suite 204 Aspen, Colorado 81611 P: 970.279.4157 F: 866.770.5585 DATE OF PUBLICATION A-301 BUILDING SECTION Flame Out Fire Protection Inc 550 Holland Hills Rd Basalt, CO 81621 (970) 927-4933 spencer@flameoutfire.net Bighorn Consulting Engineers 569 S. Westgate Drive, Suite #1 Grand Junction, CO 81505 (970) 241-8709 blaine@bighorneng.com Albright & Associates 402 Park Ave, Unit E Basalt, CO 81623 (970) 927-4363 jack@albright-associates.com Sherlock Homes Construction PO Box 17118 Snowmass Village, CO 81615 (979) 923-1122 tsherlock@sherlockhomesaspen.com 12/6/17 KF CC 1706 PARCEL ID#273718216114, 273718216115 ZONE DISTRICT 1 2 3 4 5 F-1 F-1 C-1 C-1 VIF 100'-0" SCOPE OF WORK IN DASHED AREA OCCUPANCY A-2 OCCUPANCY B OCCUPANCY B OCCUPANCY R-2 OCCUPANCY B SHOWROOM 10 1 COPY CENTER 112 CONFERENCE ROOM 104 OPEN OFFICE 113 HYMAN MALL ALLEY T.O. FF TO FINISH EXISTING FIRE SEPARATION TO REMAIN EXISTING FIRE SEPARATION PER PERMIT # 0058.2017.ACBK MAIN LEVEL 100'-0" SECOND LEVEL 109'-31/2"4'-0"1'-53/4"5'-21/4" PLATFORMPROJECTION NEW ACCESSIBILITY LIFT (REFER TO SPEC) EXISTING STANDPIPE CALL STATION CALL STATION 0 2'4'8'SCALE: 1/4" = 1'-0"A SECTION 0 2'4'8'SCALE: 1/4" = 1'-0"B SECTION Note: A 2-hour f ire-resistance rating is required for horizontal assemblies between occupancies. At time of demolition, an evaluation of the fire separation between Occupancy B and Occupancy A-2 is required and the assembly must be brought up to code if necessary. Per IBC 2015 707.3.10 STEVEN WILSON 402127STATEOFCOLO R A DOLI CE NSED AR C H ITECTDRAWING ISSUANCE INDEX ID NAME BUILDING PERMIT ISSUED DATE 9/7/17, 3:07 PM STRUCTURAL CONSULTANTS FIRE MEP COPYRIGHT CONTRACTOR 12/6/17 PROJECT NO: DRAWN BY: FORUM PHI LLC 415 E HYMAN ASPEN CO 81611 SOTHEBY'S ASPEN 715 West Main Street, Suite 204 Aspen, Colorado 81611 P: 970.279.4157 F: 866.770.5585 DATE OF PUBLICATION A-501 ASSEMBLIES Flame Out Fire Protection Inc 550 Holland Hills Rd Basalt, CO 81621 (970) 927-4933 spencer@flameoutfire.net Bighorn Consulting Engineers 569 S. Westgate Drive, Suite #1 Grand Junction, CO 81505 (970) 241-8709 blaine@bighorneng.com Albright & Associates 402 Park Ave, Unit E Basalt, CO 81623 (970) 927-4363 jack@albright-associates.com Sherlock Homes Construction PO Box 17118 Snowmass Village, CO 81615 (979) 923-1122 tsherlock@sherlockhomesaspen.com 12/6/17 KF CC 1706 PARCEL ID#273718216114, 273718216115 ZONE DISTRICT 31/2" 5/8" TYPE X GYP 5/8" TYPE X GYP WOOD STUD TYP STUD WALL PER PLAN 3'-6" GLASS WOOD STUD 5/8" TYPE X GYP PARTIAL WALL/GLASS PARTITION TWO LAYERS 5/8" GYP EXISTING JOIST PER STRUCT WOOD FLOORING SHEATHING REF STRUCT BXUV - FIRE RESISTANCE RATINGS - ANSI/UL 263 DESIGN NO. L581 PER PERMIT # 0058.2017.ACBK TWO LAYERS 5/8" GYP EXISTING FLOOR ASSEMBLY ABOVE BXUV - FIRE RESISTANCE RATINGS - ANSI/UL 263 DESIGN NO. L581 SCALE: 1 1/2"= 1'-0"W-1 TYP STUD WALL 0 6''12''18''SCALE: 1 1/2"= 1'-0"W-2 PRIVATE OFFICE PARTITIONS SCALE: 1 1/2"= 1'-0"F-1 UNRESTRAINED FIRE ASSEMBLY SCALE: 1 1/2"= 1'-0"C-1 UNRESTRAINED FIRE ASSEMBLY