Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.415 E Hyman Ave.0033.2018 (4).ACBK
SlimSurfaceLED-5in-7in-Round-S5R-S7R 09/17 page 1 of 7 Project: Location: Cat.No: Type: Lamps: Qty: Notes: Downlighting 5" and 7" round aperture surface mount downlight SlimSurface LED White Black Aluminum Ordering guide example: S5R830K7AL Family CRI CCT Lumens Finish Dimming S5R SlimSurface 5" Round 8 80 9 90 1 27K 2700K 30K 3000K 35K 3500K 40K 4000K 7 650 lm blank White AL Aluminum BK Black blank ELV / Triac (120V) W White AL Aluminum BK Black Z10U 0-10V (120V-277V) S7R SlimSurface 7" Round 8 80 9 90 1 27K 2700K 30K 3000K 35K 3500K 40K 4000K 10 1000 lm blank White AL Aluminum BK Black blank ELV / Triac (120V) W White AL Aluminum BK Black Z10U 0-10V (120V-277V) 1. Configurations using 90 CRI are only available with 2700K and 3000K CCT. Features 1. Flange: One piece plastic flange. Injection molded white, applied aluminum or black. 2. Lens: High transmittance lens allowing for smooth, comfortable light pattern. 3. Power supply: Integral class 2 driver. Factory wired electronic LED driver (see Electrical section for specifications) 4. LED Strip: Utilizes Philips LEDs. 5. Lifetime: Expected lifetime 50,000 hours and backed by a 5-year warranty (see Philips.com/warranties for details). 6. Compliance: Non-conductive fixture for shower light application. Electrical Electronic power supply: RoHS compliant. Class 2 power unit. Unit tolerates sustained open circuit and short circuit output conditions without damage. Dimming: Intended for ELV/Triac (120V) or 0-10V dimming (120V-277V) based on the configuration. Min 90°C supply conductors. Labels cULus listed. Wall-mounted: damp location only. Ceiling-mounted: wet location. Title 24 (JA8-2016) on 90CRI S7R models. ENERGY STAR® certified. Electrical specifications Dimming Input volts Input frequency Input current Input Power THD Factor Power Factor Minimum Operating Temp. Slim 5" 650lm Triac 120V 50/60Hz 0.08A 9.5W <15%>0.9 -20°C 0-10V 120V 50/60Hz 0.09A 10.1W <20%>0.9 -20°C 277V 50/60Hz 0.04A 10.2W <20%>0.9 -20°C Slim 7" 1000lm Triac 120V 50/60Hz 0.13A 14.2W <15%>0.9 -20°C 0-10V 120V 50/60Hz 0.12A 14.4W <20%>0.9 -20°C 277V 50/60Hz 0.06A 14.7W <20%>0.9 -20°C Fore more details, please see LED-Dim spec sheet. SlimSurface LED is a 5/8" thick surface mounted luminaire with the appearance of a recessed downlight. Easy to install into most standard j-boxes, the SlimSurface LED round apertures are available as a 5" 650 lm & 7" 1000 lm fixture. 3/07/2018 SlimSurfaceLED-5in-7in-Round-S5R-S7R 09/17 page 2 of 7 S5R & S7R SlimSurface LED 5" and 7" round aperture surface mount downlight Compatibility Installs into standard J-box applications: Note: A 2 1/8" deep octagon junction box is recommended for through circuit wiring applications. 3 1/2" round (plastic)4" square (plastic) Not compatible with S5R 4" octagonal (metal)4" square (metal) Not compatible with S5R Fire rated J-box Fire rated classification is per the ceiling and junction box ratings. Dimensions SlimSurface LED 5" downlight SlimSurface LED 7" downlight Ø 5 3 8"137 mm Ø 4 1 2"115 mm 5 8"16 mm Ø 5 3 8" 137 mm Ø 7 7 8" 201 mm Ø 7 7 8"201 mm Ø 7"179 mm 5 8"16 mm Ø 5 3 8"137 mm Ø 4 1 2"115 mm 5 8"16 mm Ø 5 3 8" 137 mm Ø 5 3 8"137 mm Ø 4 1 2"115 mm 5 8"16 mm Ø 5 3 8" 137 mm Ø 7 7 8" 201 mm Ø 7 7 8"201 mm Ø 7"179 mm 5 8"16 mm Ø 7 7 8" 201 mm Ø 7 7 8"201 mm Ø 7"179 mm 5 8"16 mm 3/07/2018 SlimSurfaceLED-5in-7in-Round-S5R-S7R 09/17 page 3 of 7 S5R & S7R SlimSurface LED 5" and 7" round aperture surface mount downlight 75 150 225 300 375 60° 30° Candela Curves 75 150 225 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 266 263 261 260 254 239 217 190 160 118 81 55 40 30 23 18 11 4 0 25 736 110 118 91 51 31 18 5 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 208 326 469 522 39.8% 62.5% 89.7% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 64 59 54 50 47 119 103 90 79 70 63 57 51 47 43 40 119 100 85 73 64 57 51 46 42 38 35 116 105 94 84 76 70 64 58 54 50 46 116 98 84 73 64 57 51 46 41 38 35 111 100 90 82 74 68 62 57 53 49 45 111 95 82 72 63 56 50 45 41 38 34 106 97 87 79 72 66 60 56 51 48 44 106 92 80 70 62 56 50 45 41 37 34 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 11 7 5 4 3 6.0' 7.2' 8.4' 9.6' 10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 21.8 14.2 10.2 8.5 6.8 0.40 0.26 0.19 0.16 0.13 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S5R927K7 • 10 W LED, 90 CRI, 2700 K 1. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. 2. Wattage: controlled to within 5% 3. Correlated Color Temperature: within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 150 300 450 600 750 60° 30° Candela Curves 150 300 45050 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 496 490 479 464 433 391 348 309 265 197 135 92 68 51 40 30 21 9 0 46 130 180 193 152 85 52 32 10 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 356 549 786 880 40.5% 62.4% 89.3% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 65 59 55 51 47 119 103 90 79 70 63 57 52 47 43 40 119 100 85 74 65 57 51 46 42 38 35 116 104 94 85 77 70 64 59 54 50 47 116 98 84 73 64 57 51 46 42 38 35 111 100 90 82 74 68 62 57 53 49 46 111 95 82 72 63 56 51 46 42 38 35 106 96 87 79 72 66 61 56 52 48 45 106 92 80 71 62 56 50 45 41 38 35 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 20 14 10 8 6 5.5' 6.6' 7.7' 8.8' 9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 21.8 14.2 10.2 8.5 6.8 2.89 1.90 1.35 1.13 0.90 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S7R927K10 • 14 W LED, 90 CRI, 2700 K CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% Report1: 1053GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 523 lms 1.2 87° 9.1 W Efficacy: CCT3: CRI: 57.4 lm/w 2700 K 90 min Report1: 962GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 880 lms 1.1 83° 13.5 W Efficacy: CCT3: CRI: 65.2 lm/w 2700 K 90 min 3/07/2018 SlimSurfaceLED-5in-7in-Round-S5R-S7R 09/17 page 4 of 7 S5R & S7R SlimSurface LED 5" and 7" round aperture surface mount downlight 75 150 225 300 375 60° 30° Candela Curves 75 150 225 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 294 291 289 288 281 265 241 211 178 131 91 62 45 34 26 20 13 4 0 28 81 121 131 102 57 34 21 5 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 231 362 521 581 39.7% 62.3% 89.6% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 64 59 54 50 47 119 103 90 79 70 63 57 51 47 43 40 119 100 85 73 64 57 51 46 42 38 35 116 105 94 84 76 70 64 58 54 50 46 116 105 94 84 76 70 64 58 54 50 46 111 100 90 82 74 68 62 57 53 49 45 111 95 82 72 63 56 50 45 41 38 34 106 97 87 79 72 66 60 56 51 48 44 106 92 80 70 62 56 50 45 41 37 34 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 12 8 6 5 4 6.0' 7.2' 8.4' 9.6' 10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 24.2 15.8 11.3 9.5 7.5 2.77 1.82 1.30 1.08 0.87 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S5R827K7 • 10 W LED, 80 CRI, 2700 K 150 300 450 600 750 60° 30° Candela Curves 150 300 450 60600 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 625 618 604 584 546 494 440 390 337 250 170 117 85 65 51 39 27 12 0 59 164 227 244 193 108 65 41 13 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 449 693 994 1113 40.4% 62.3% 89.3% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 65 59 55 51 47 119 103 90 79 70 63 57 52 47 43 40 119 100 85 74 65 57 51 46 42 38 35 116 104 94 85 77 70 64 59 54 50 47 116 98 84 73 64 57 51 46 42 38 35 111 100 90 82 74 68 62 57 53 49 46 111 95 82 72 63 56 51 46 42 38 35 106 96 87 79 72 66 61 56 52 48 45 106 92 80 71 62 56 50 45 41 38 35 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 25 17 13 10 8 5.5' 6.6' 7.7' 8.8' 9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 24.2 15.8 11.3 9.5 7.5 3.68 2.42 1.73 1.44 1.15 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S7R827K10 • 14 W LED, 80 CRI, 2700 K CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% Report1: 1054GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 581 lms 1.2 87° 9.3 W Efficacy: CCT3: CRI: 62.5 lm/w 2700 K 80 min 1. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. 2. Wattage: controlled to within 5% 3. Correlated Color Temperature: within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. Report1: 964GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 1113 lms 1.1 83° 13.4 W Efficacy: CCT3: CRI: 83.1 lm/w 2700 K 80 min 3/07/2018 SlimSurfaceLED-5in-7in-Round-S5R-S7R 09/17 page 5 of 7 S5R & S7R SlimSurface LED 5" and 7" round aperture surface mount downlight 75 150 225 300 375 60° 30° Candela Curves 75 150 225 300300 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 319 315 313 313 306 290 264 231 197 146 100 69 50 38 29 22 15 6 0 30 88 131 142 109 62 37 22 6 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 249 391 562 628 39.7% 62.3% 89.6% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 64 59 54 50 47 119 103 90 79 70 63 57 51 47 43 40 119 100 85 73 64 57 51 46 42 38 35 116 105 94 84 76 70 64 58 54 50 46 116 98 84 73 64 57 51 46 41 38 35 111 100 90 82 74 68 62 57 53 49 45 111 95 82 72 63 56 50 45 41 38 34 106 97 87 79 72 66 60 56 51 48 44 106 92 80 70 62 56 50 45 41 37 34 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 13 9 7 5 4 6.0' 7.2' 8.4' 9.6' 10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 26.2 17.1 12.2 10.2 8.1 3.06 2.01 1.43 1.19 0.96 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S5R830K7 • 10 W LED, 80 CRI, 3000 K 150 300 450 600 750 60° 30° Candela Curves 150 300 450 6 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 607 601 588 568 531 480 427 379 328 243 165 113 83 63 49 37 26 12 0 57 159 221 237 187 105 63 39 13 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 437 674 966 1081 40.4% 62.3% 89.4% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 65 59 55 51 47 119 103 90 79 70 63 57 52 47 43 40 119 100 85 74 65 57 51 46 42 38 35 116 104 94 85 77 70 64 59 54 50 47 116 98 84 73 64 57 51 46 42 38 35 111 100 90 82 74 68 62 57 53 49 46 111 95 82 72 63 56 51 46 42 38 35 106 96 87 79 72 66 61 56 52 48 45 106 92 80 71 62 56 50 45 41 38 35 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 24 17 12 9 7 5.5' 6.6' 7.7' 8.8' 9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 26.2 17.1 12.2 10.2 8.1 3.55 2.33 1.66 1.39 1.11 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S7R830K10 • 14 W LED , 80 CRI, 3000 K CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% Report1: 1055GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 628 lms 1.2 87° 9.1 W Efficacy: CCT3: CRI: 69.0 lm/w 3000 K 80 min Report1: 961GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 1081 lms 1.1 83° 13.5 W Efficacy: CCT3: CRI: 80.0 lm/w 3000 K 80 min 1. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. 2. Wattage: controlled to within 5% 3. Correlated Color Temperature: within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 3/07/2018 SlimSurfaceLED-5in-7in-Round-S5R-S7R 09/17 page 6 of 7 S5R & S7R SlimSurface LED 5" and 7" round aperture surface mount downlight 75 150 225 300 375 60° 30° Candela Curves 75 150 225 300 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 347 344 341 340 332 312 283 248 209 154 107 74 53 41 31 23 15 5 0 33 96 143 155 119 68 41 25 7 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 272 426 613 685 39.6% 62.2% 89.5% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 64 59 54 50 47 119 103 90 79 70 63 57 51 47 43 40 119 100 85 73 64 57 51 46 42 38 35 116 105 94 84 76 70 64 58 54 50 46 116 98 84 73 64 57 51 46 41 38 35 111 100 90 82 74 68 62 57 53 49 45 111 95 82 72 63 56 50 45 41 38 34 111 95 82 72 63 56 50 45 41 38 34 106 92 80 70 62 56 50 45 41 37 34 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 14 10 7 5 4 6.0' 7.2' 8.4' 9.6' 10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 28.6 18.7 13.3 11.2 8.9 3.34 2.19 1.56 1.30 1.04 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S5R835K7 • 10 W LED, 80 CRI, 3500 K 150 300 450 600 750 60° 30° Candela Curves 150 300 450 600600 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 639 632 618 597 558 505 449 399 345 255 174 120 88 67 52 40 28 12 0 60 167 232 249 197 111 67 42 13 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 459 708 1016 1139 40.3% 62.2% 89.2% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 65 59 55 51 47 119 103 90 79 70 63 57 52 47 43 40 119 100 85 74 65 57 51 46 42 38 35 116 104 94 85 77 70 64 59 54 50 47 116 98 84 73 64 57 51 46 42 38 35 111 100 90 82 74 68 62 57 53 49 46 111 95 82 72 63 56 51 46 42 38 35 106 96 87 79 72 66 61 56 52 48 45 106 92 80 71 62 56 50 45 41 38 35 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 26 18 13 10 8 5.5' 6.6' 7.7' 8.8' 9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 28.6 18.7 13.3 11.2 8.9 3.74 2.45 1.75 1.46 1.17 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S7R835K10 • 14 W LED, 80 CRI, 3500 K CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% Report1: 1056GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 685 lms 1.2 87° 9.1 W Efficacy: CCT3: CRI: 75.3 lm/w 3500 K 80 min Report1: 965GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 1139 lms 1.1 83° 13.5 W Efficacy: CCT3: CRI: 84.4 lm/w 3500 K 80 min 1. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. 2. Wattage: controlled to within 5% 3. Correlated Color Temperature: within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 3/07/2018 SlimSurfaceLED-5in-7in-Round-S5R-S7R 09/17 page 7 of 7 S5R & S7R SlimSurface LED 5" and 7" round aperture surface mount downlight 75 150 225 300 375 60° 30° Candela Curves 75 150 225 300 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 366 363 360 359 350 329 299 262 221 163 113 79 57 44 34 25 16 6 0 35 101 151 163 126 72 44 27 7 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 286 450 648 726 39.5% 62.0% 89.3% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 64 59 54 50 47 119 103 90 79 70 63 57 51 47 43 40 119 100 85 73 64 57 51 46 42 38 35 116 105 94 84 76 70 64 58 54 50 46 116 98 84 73 64 57 51 46 41 38 35 111 100 90 82 74 68 62 57 53 49 45 111 95 82 72 63 56 50 45 41 38 34 106 97 87 79 72 66 60 56 51 48 44 106 92 80 70 62 56 50 45 41 37 34 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 15 10 7 6 5 6.0' 7.2' 8.4' 9.6' 10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 30.3 19.8 14.1 11.8 9.4 3.54 2.32 1.66 1.38 1.10 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S5R840K7 • 10 W LED, 80 CRI, 4000 K 1. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products. 2. Wattage: controlled to within 5% 3. Correlated Color Temperature: within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 150 300 450 600 750 60° 30° Candela Curves 150 300 450 600 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 710 702 686 663 620 560 499 443 382 283 193 133 97 74 57 44 30 14 0 66 186 258 276 218 122 74 46 15 Zonal lumens & percentages Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 510 786 1127 1262 40.4% 62.3% 89.3% 100.0% Coefficients of utilization Ceiling 80%70% 50%30%0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 111 102 95 88 82 76 71 67 63 59 119 107 96 86 78 71 65 59 55 51 47 119 103 90 79 70 63 57 52 47 43 40 119 100 85 74 65 57 51 46 42 38 35 116 104 94 85 77 70 64 59 54 50 47 116 98 84 73 64 57 51 46 42 38 35 111 100 90 82 74 68 62 57 53 49 46 111 95 82 72 63 56 51 46 42 38 35 106 96 87 79 72 66 61 56 52 48 45 106 92 80 71 62 56 50 45 41 38 35 100 88 77 67 60 53 48 43 39 36 33 Single unit data Height to Lighted Plane Initial center beam foot-candles Beam dia. (ft)* 5' 6' 7' 8' 9' 28 20 14 11 9 5.5' 6.6' 7.7' 8.8' 9.9' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq.ft. 5' 6' 7' 8' 9' 30.3 19.8 14.1 11.8 9.4 4.17 2.74 1.96 1.63 1.30 38'x38'x10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances S7R840K10 • 14 W LED, 90 CRI, 2700 K CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% CRI and CCT adjustment factors 90 CRI 2700K =84% 80 CRI 2700K =100% 80 CRI 3000K =100% 80 CRI 3500K =105% 80 CRI 4000K =109% © 2016 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Philips Lighting North America Corporation 200 Franklin Square Drive, Somerset, NJ 08873 Tel. 855-486-2216 Philips Lighting Canada Ltd. 281 Hillmount Rd, Markham, ON, Canada L6C 2S3 Tel. 800-668-9008 Report1: 1057GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 726 lms 1.2 87° 9.1 W Efficacy: CCT3: CRI: 79.8 lm/w 4000 K 80 min Report1: 963GFR Output lumens: Spacing Criterion: Beam Angle: Input Watts2: 1262 lms 1.1 83° 13.4 W Efficacy: CCT3: CRI: 94.2 lm/w 4000 K 80 min 3/07/2018