Loading...
HomeMy WebLinkAboutMaster Permit.447 E Cooper Ave.0013.2019.ARBKEXISTING & PROPOSEDFLOOR PLANSID1.0SHEET:REVISION DATE:SHEET TITLE:--447 E. COOPER HOLDINGS CONDO ARCHITECT: BUILDER:--PERMIT SET DATE:11142018CTS CONSCIOUSLY TRANSFORMING SPACE, LLC FUNCTIONAL DESIGN - SPACE PLANNING - INTERIORS 447 E. COOPER AVE., UNIT 1 ASPEN, CO 81611 CANDICE HART phn. 720.635.1818 email: candice@cts-colorado.com WALL TYPE LEGEND:EXISITNG FLOOR PLAN WITH DEMOLITIONSCALE:1/4" = 1'-0"1KITCHENDININGLIVINGHALLENTRYLAUNDRYFAMILYBEDROOM #2MAINBATHMASTERBEDROOMMASTERBATHCLOSETBEDROOM #3BEDROOM #4PATIOALLEYSIDEMALLSIDEPROPOSED FLOOR PLAN SCALE:1/4" = 1'-0"2KITCHENDININGLIVINGBEDROOM #3HALLENTRYGUESTBATHLAUNDRYFAMILYGUEST MASTERBEDROOM #2MAINBATHMASTERBEDROOMMASTERBATHCLOSETGUESTCLOSETPATIOALLEYSIDEMALLSIDExxBUILDING INFO:GENERAL NOTES:12 - 21 - 18 PERMIT RESUBMITTAL 201/17/2019F2015 IBC Residential Code ReferencesL75% of lamps in permanently installed lights must be high efficacy, 2015 IECC R404.1COCarbon monoxide detector required per Aspen Municipal Code 8.15DEClothes dryer exhaust, 2015 IMC 504. Makeup air required if over 200 CFMDVDirect vent sealed combustion required, 2015 IFGC 303.3ETExhausts terminate 3ft from prop line and openings, 10ft from intakes, 2015 IMC 501.3.1MAMake up air required if hood exhausts greater than 400 CFM, 2015 IMC 505.2VMechanical ventilation required, Ordinance 40, 2016 (bath fans and balanced whole house ventilation)FNew or replacement fenestration shall not exceed 0.28 U-factor, NFRC label required, Ordinance 40, 2016SGSafety glazing required, 2015 IBC 2406SASmoke alarm per NFPA 72 required, 2015 IBC 907.2.11SASASASACOCO02/07/201902/07/2019nicktSGMADVSGVVVVDEETREVIEWED FORCOMPLIANCE02/12/2019 sarahyBY HPCEEEEEE0013.2019.ARBK447 East Cooper Ave Holdings LLC447 E Cooper Ave273718221011 EXISTING PHOTOS &SPECIFICATIONSID1.1SHEET:REVISION DATE:SHEET TITLE:--447 E. COOPER HOLDINGS CONDO ARCHITECT: BUILDER:--PERMIT SET DATE:11142018CTS CONSCIOUSLY TRANSFORMING SPACE, LLC FUNCTIONAL DESIGN - SPACE PLANNING - INTERIORS 447 E. COOPER AVE., UNIT 1 ASPEN, CO 81611 CANDICE HART phn. 720.635.1818 email: candice@cts-colorado.comEXISTING PATIO ABOVE ALLEYSCALE:NOT TO SCALE2PHOTO OF MALL SIDE FACADESCALE:NOT TO SCALE1SOUND DAMPENING GYPSUM BOARD SPECIFICATIONSSCALE:NOT TO SCALE7FLOOR UNDERLAYMENT SPECIFICATIONSSCALE:NOT TO SCALE6PROPERTY LINE FROM MALL SIDESCALE:NOT TO SCALEVIEW OF xxxxx4EXISTING PATIO ABOVE ALLEYSCALE:NOT TO SCALE3PROPERTY LINE FROM ALLEY SIDESCALE:NOT TO SCALEVIEW OF 512 - 21 - 18 PERMIT RESUBMITTAL 201/17/2019Fill cavities withinsulation. 2015 IECCR503.1.1.F02/07/2019nicktREVIEWED FORCOMPLIANCE02/12/2019 sarahyBY HPC PROPOSED FURNITUREFLOOR PLANID1.2SHEET:REVISION DATE:SHEET TITLE:--447 E. COOPER HOLDINGS CONDO ARCHITECT: BUILDER:--PERMIT SET DATE:11142018CTS CONSCIOUSLY TRANSFORMING SPACE, LLC FUNCTIONAL DESIGN - SPACE PLANNING - INTERIORS 447 E. COOPER AVE., UNIT 1 ASPEN, CO 81611 CANDICE HART phn. 720.635.1818 email: candice@cts-colorado.com WALL TYPE LEGEND:PROPOSED FURNITURE PLAN SCALE:1/4" = 1'-0"1KITCHENDININGLIVINGBEDROOM #3HALLENTRYGUESTBATHLAUNDRYFAMILYGUEST MASTERBEDROOM #2MAINBATHMASTERBATHCLOSETGUESTCLOSETPATIOSPLIT KING LAYOUTSCALE:1/4" = 1'-0"GUEST MASTER BEDROOM #2 2ALLEYSIDEMALLSIDECLOSETMASTERBEDROOMGENERAL NOTES:01/17/201902/07/201902/07/2019nicktREVIEWED FORCOMPLIANCE02/12/2019 sarahyBY HPC EXISTING & PROPOSEDELECTRICAL &LIGHTING PLANSID2.0SHEET:REVISION DATE:SHEET TITLE:--447 E. COOPER HOLDINGS CONDO ARCHITECT: BUILDER:--PERMIT SET DATE:11142018CTS CONSCIOUSLY TRANSFORMING SPACE, LLC FUNCTIONAL DESIGN - SPACE PLANNING - INTERIORS 447 E. COOPER AVE., UNIT 1 ASPEN, CO 81611 CANDICE HART phn. 720.635.1818 email: candice@cts-colorado.comEXISITNG ELECTRICAL & LIGHTING PLANSCALE:1/4" = 1'-0"1KITCHENDININGLIVINGHALLENTRYLAUNDRYFAMILYBEDROOM #2MAINBATHMASTERBEDROOMMASTERBATHCLOSETBEDROOM #3BEDROOM #4PROPOSED ELECTRICAL & LIGHTING PLAN SCALE:1/4" = 1'-0"2KITCHENDININGLIVINGBEDROOM #3HALLENTRYGUESTBATHFAMILYGUEST MASTERBEDROOM #2MAINBATHMASTERBEDROOMMASTERBATHCLOSETGUESTCLOSETPATIOPATIOGENERAL NOTESELECTRICAL/LIGHTING LEGENDLAUNDRYWALL TYPE LEGEND:EXTERIOR WALL SCONCE SPEC.SCALE:NOT TO SCALE44" RECESSED LED CAN SPEC.SCALE:NOT TO SCALE312 - 21 - 18 PERMIT RESUBMITTAL 201/17/201902/07/2019Please ensure conformity with 26.575.150.F (a) -Residential Lighting Standards. "Outdoor lightingshall be twelve (12) feet or less in height unless itmeets one of the following criteria: The lighting isused to illuminate above grade decks or balconies,is fully shielded and the point light source is notvisible beyond the boundaries of the property inwhich it is located"ALL OUTDOOR LIGHTINGMUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODESECTION 26.575.15002/07/2019nicktLREVIEWED FORCOMPLIANCE02/12/2019 sarahyBY HPC EXISTING & PROPOSEDROOF PLANSSHEET:REVISION DATE:SHEET TITLE:--447 E. COOPER HOLDINGS CONDO ARCHITECT: BUILDER:--PERMIT SET DATE:11142018CTS CONSCIOUSLY TRANSFORMING SPACE, LLC FUNCTIONAL DESIGN - SPACE PLANNING - INTERIORS 447 E. COOPER AVE., UNIT 1 ASPEN, CO 81611 MARCUS HOLLINS Cell: 970.309.4572 hollinsmarcus@gmail.com CANDICE HART phn. 720.635.1818 email: candice@cts-colorado.com N/A ID3.0DRAWN BY: BRAUM & ASSOCIATES, LLCEXISITNG ROOF PLANSCALE:1/4" = 1'-0"1PROPOSED ROOF PLAN SCALE:1/4" = 1'-0"211 - 21 - 18 PERMIT RESUBMITTAL 112 - 21 - 18 PERMIT RESUBMITTAL 202 - 12 - 19 PERMIT RESUBMITTAL 302/12/2019REVIEWED FORCOMPLIANCE02/12/2019 sarahyBY HPC2/07/20192/07/19NickT