Loading...
HomeMy WebLinkAboutFile Documents.845 Meadows Rd.0014.2017 (12).ACBKz E CO N ENVIRONMENTAL CONSULTANTS ...bventhe' ... Lead Based Paint Survey - Testing & Analysis - Construction Specific Project Site: The Aspen Meadows Reception Center - The Aspen Institute, Aspen, Colorado Client: The Aspen Institute, 880 Meadows Road, Aspen, Colorado 81611 Survey Date: March 3, 2017 Phase Con Project #: 17-03-03D 2166 Peregrine " -ourt Grand Junction, CO 83 607 Office: 37 -260-334"' pceconsuitants@qwestoffice.net Aspen Meadows Reception Center, Aspen, Colorado Sampling Description Phase Con provided construction specific Lead Based Paint (LBP) Survey services at the Aspen Meadows Reception Center at The Aspen Institute in Aspen, Colorado on March 3, 2017. The scope of work was limited to testing of surfaces which were suspect for the presence of LBP and which would be impacted in the planned renovation work as described by the client's representative. Paint chip samples were obtained from several painted surfaces by a Colorado State and EPA certified LBP Risk Assessor, Mr. Douglas Close, and submitted for analysis to an ELLAP accredited laboratory. Discussion & Recommendations Laboratory analysis of the samples obtained can be summarized as follows: None of the paint samples showed the presence of Lead Based Paint. No special precautions for LBP will need to be employed in the planned renovation work which will impact the tested surfaces. Erouglas A. Close Colorado State and EPA Certified Lead Based Paint Risk Assessor #8804 Sample Description Table Aspen Meadows Reception Center, The Aspen Institute, Aspen, Colorado Paint Chip Sample Description and Location Tables Sample # Sample Descriptions and Locations PC -01 Pre -Stress Concrete Ceiling Surfaces - Kitchen 0.0034 mg lead/sq cm PC -02 Pre -Stress Concrete Ceiling Surfaces - Bsmnt <0.0018 mg lead/sq cm PC -03 CMU Walls - Basement <0.0018 mg lead/sq cm PC -04 Brick Wall - Beneath Stairs - Mid Level Representative of Upper Fireplace 0.027 mg lead/sq cm PC -05 Brick Fireplace - Mid Level Dining Room 0.017 mg lead/sq cm ------------------------------------- ------------------------------------- Lead Based Paint Classification = >1.0 mg lead/sq cm Laboratory Analysis Results hNst Laboratvr%es' Environmental Hazards Services, L.L.C. 7469 Whitepine Rd Richmond, VA 23237 Telephone: 800.347.4010 Client: Phase Con 2166 Peregrine Ct Grand Junction, CO 81507 Lead Paint Chip Analysis Report Report Number: 17-03-00852 Received Date: 03/07/2017 Analyzed Date: 03/08/2017 Reported Date: 03/08/2017 Project/Test Address: Aspen Institute; Aspen, CO Collection Date: 03/03/2017 Client "umber: 06-5735 Laboratory Results Fax Number: 970-241-6584 Lab Sample Client Sample Collection Location Pb Narrative Number Number mg/cm, ID 17-03-00852-001 PC -01 0.0034 17-03-00852-002 PC -02 <0.0018 17-03-00852-003 PC -03 <0.0018 17-03-00852-004 PC -04 0.027 17-03-00852-005 PC -05 0.017 Page 1 of 2 Environmental Hazards Services, L.L.0 Client Number: 06-5735 Report Number: 17-03-00852 Project/Test Address: Aspen Institute; Aspen, CO Lab Sample Client Sample Collection Location Pb Narrative Number Number mg/cm, ID Preparation Method: EPA SW846 3050B Analysis Method: EPA SW846 70008 Reviewed By Authorized Signatory: Deborah Britt QA/QC Clerk The HUD lead guidelines for lead paint chips are 0.50% by Weight, 5000 ppm, or 1.0 mg/cm2. The Reporting Limit (RL) for samples prepared by ASTM E-1979-12 is 10.0 ug Total Pb. The RL for samples prepared by EPA SW846 30506 is 25.0 ug Total Pb. Paint chip area and results are calculated based on area measurements determined by the client. All internal quality control requirements associated with this batch were met, unless otherwise noted. The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the client. Sample location, description, area, etc., was provided by the client. Results reported above in mg/cm3 are calculated based on area supplied by client. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714. LEGEND Pb= lead ug = microgram ppm = parts per million ug/g = micrograms per gram Wt. = weight Page 2 of 2 ti O LIDW 0 O N U LID LO a+ M OD O p 'W L9 co 0 ('!) O O Q E Q M z 0 U U N C N U 0 W �ta 3 cr0 low N C 0 E E 0 U a� �ta (\ F H n M E E E c � � d K X X X X X X x.5.5 y Certificates W, ':�_ ROLi�SY.r^�r��MtflRHtlit "A �0.11xYA� H:1C Colorado Department of Public Health and Environment LEAD-BASED PAINT CERTIFICATION* This certifies that Douglas A. Close Certification No.: 8804 has met the requirements of 25-7-1104, C.R.S. and Air Quality Control Commission Regulation No. 19, and is hereby certified by the state of Colorado in the following discipline: Risk Assessor* Issued: September 08, 20t6 Expires: September 08, 2019 x This certificate is valid only with the possession of u valid lend -bused paint training certificate in the discipline specified above, issued by either a Colorado approved training provider, an EPA approved training provider, or a training provider approved by another EPA authorized prograhn. Auth sized AP.,D Representative SEAL