HomeMy WebLinkAboutFile Documents.845 Meadows Rd.0048.2018 (5).ACBKJEFFREY BERKUS A R C H I T E C T S •00 WEST MAIN STREET SUITE 120 ASPEN, CO 81611 970.925.7017 P 970.925.7026 F 924 ANACAPA STREET SUITE 1B SANTA BARBARA, CA 93101 805.963.8902 P 805-966-1549 F www.jeffreyberkusarchitects.com May 23, 2018 City of Aspen - Building Department Attn: Stephen Kanipe 201 North Mill Street Garden Level Aspen, CO 81611 Re: Dining Area 104 Egress / Letter of Alternative Method Stephen, The existing historic condition of Dining Room 105 only has one means of egress out of the east side of the space as shown in the exhibit below which should limit us to an occu- pant load of 49 persons or less: 13oio 30701 SE RVM CORRIDOR HR 4MO wo=e DINWOAREA — �:_�-amaeA----em�e�e-�� Exhibit 1 The existing dining area served approximately 98 person prior to the remodel. We would like to be able to reuse this same space with the same occupant loading. (See Exhibit 2) IBC Table 1004.1.2 Concentrated (Chairs Only) 1,026 SF / 7 = 147 Person Standing Space 1,026 SF / 5 = 205 Person Unconcentrated (Tables + Chairs) 1,026 SF / 15 = 68 Person *Total square footage of space minus access corridor Exhibit 2 An additional west door has been added in the remodeled space which opens to an egress balcony. How- ever the balcony is noncompliant due to a dead end travel condition requiring traversing past unprotected glass adjacent. However, the balcony is 12 feet wide and the unprotected windows are at another dining area (Dining 105) with limited fire load and the entire building will be fire sprinklered. The new door will have code compliant exit signage and panic hardware. (See Exhibit 2) In keeping with this historic integrity of the building we would like your consideration to apply the follow- ing code section to allow the west door to become a secondary means of egress from the space allowing us to load the space for more than 49 people. 2015 International Existing Building Code - Section 805.2.2 / General / Exception 2 2. Means of egress conforming to the requirements of the building code under which the building was constructed shall be considered complaint means of egress if, in the opinion of the code official, they do not constitute a distinct hazard to life. Sincerely, s e Nick Ketpura PROJECT MANAGER JEF F RE Y BE R KUS A RC H ITEC TS, INC. 400 West Main Street, Aspen CO 81611 P (970) 236-2431 This alternate method is acceptable as it meets the intent of 2015 IEBC 805.2.2 and is equivalent in fire and life safety.