File Documents.845 Meadows Rd.0048.2018 (2).ACBK
0048-2018-ACBK_BuildingComments_1complete Page: [15] A2.01 Basement Level Floor Plan (North) Enlarged File Name: ARCH SET Change Order 2018-04-12.pdf Subject: PlanCheck Author: nickt Color: Panic hardware required 2017 NEC 110.26(C)(3) ARCH SET Change Order 2018-04-12.pdf (6) Page: [15] A2.01 Basement Level Floor Plan (North) Enlarged File Name: ARCH SET Change Order 2018-04-12.pdf Subject: PlanCheck Author: nickt Color: Boiler room must have a 1 hour horizontal assembly above. Fire barrier walls must be continuous to the underside of the concrete deck above. Where is this described? Page: [19] A2.11 Lower Level Floor Plan (North) Enlarged File Name: ARCH SET Change Order 2018-04-12.pdf Subject: PlanCheck Author: nickt Color: Elevator machine room mechanical room must have 1 hour horizontal assembly above and below. Fire barrier walls must be continuous to the underside of the concrete deck above. Where is this described? Page: [65] A7.01 Schedules File Name: ARCH SET Change Order 2018-04-12.pdf Subject: PlanCheck Author: nickt Color: 45 minute door required to boiler room for 1 hour fire barrier for incidental use per 2015 IBC 716.5. Page: [79] A9.07 Interior Elevations File Name: ARCH SET Change Order 2018-04-12.pdf Subject: PlanCheck Author: nickt Color: Dimension space between door jamb and lavatory. Must be 18" min per ICC A117.1-2009 section 404.2.3.2. 1 BA EXISTINGELEC. 001 EXISTINGCOMM.002 REVISEDFREEZER003 MENSLOCKER005 BOILER ROOM009 EXISTINGLIFT FRIDGE004 CLOSET W6A6.01 W10A6.01 W10A6.01 W8A6.01 W18A6.03 W8A6.01 STAIR 005 EXISTING EXISTING EXISTING1'-0"5'-0"4'-0""3 1/2"2'-2"6'-5 7/8"5'-3 13/16"6"7"6"16"1'-7 3/8"6"℄DOOR5'-1 7/8"3 1/2"2'-5 7/8"2'-9 1/4" 4" 3 5/8"3'-1 1/4" 3 1/2"7'-9"3 5/8"6'-6 1/4"3 5/8"5'-2 11/16"/16"1/005 1/0021/001EXISTINGELEC. 001 EXISTINGCOMM.002 REVISEDFREEZER003 MENSLOCKER005 BOILER ROOM009 EXISTINGLIFT FRIDGE004 HALL011 ELEVATOR01 STAIR 005 W6A6.01 W10A6.01 W10A6.01 W17A6.03 W8A6.01 EXISTING EXISTING EXISTINGEXISTING 4/011 VF-1CF-1 VF-1T2 W14A6.02 W10 A6.01 9'-3 5/8"13'-10 1/8"6'-3 1/4"6'-11 13/16"12'-1 3/8"5'-0 1/2"7 5/8"14'-10 3/8" T.O.S.90'-10 1/4" 3 5/8"5'-3 1/4"3 5/8"F.O.S. 2" OFFCONC.T WEB 9'-10 3/8"6"1'-10 1/8" ℄DOOR FULL HEIGHT WALL TILED LEDGECLOSET UPSTAIR 7 5/8"7 5/8"6"2"6"5 5/8"1 1/2" HAT CHANNEL @FRONT OF PLUMBING SKID& 6" STUD ABOVE SKID A6.06.13 W18A6.03 Panic hardwarerequired 2017 NEC110.26(C)(3) EXISTINGELEC.001 EXISTINGCOMM.002 REVISEDFREEZER003 MENSLOCKER005 BOILER ROOM009 WOMENSLOCKER006 KITCHEN DRY GOODS012 EXISTINGLIFT FRIDGE004 CLOSET KITCHEN DRY GOODS010 HALL011 W66.01 W6A6.01 W10A6.01 W10A6.01 W10A6.01 W4A6.01 W8A6.01 W14A6.02 W8A6.01 W8A6.01 W4A6.01 W8A6.01 W18A6.03 W8A6.01 ELEVATOR02 W12A6.01 3/011 STAIR005 EXISTING FOOTERTO REMAINEXISTING FOOTERTO REMAIN EXISTING EXISTING EXISTING EXISTINGEXISTING EXISTING EXISTING1'-0"5'-0"4'-0"1'-6"1'-0"5'-0"4'-0"1'-6"1'-0"5'-0" 1'-0" 1'-6"4'-0"5'-0"1'-6" 1'-0"4'-0"5'-0"1'-10 5/8" ℄DOOR 5'-10 5/16"6"3 5/8"6'-8 3/8"7/8"3 5/8"3 1/2"3 1/2"8'-0 1/2"3 5/8"6'-6 1/4"3 1/2"2'-2"6'-5 7/8"5'-3 13/16"6"7"6"5'-1 3/16"6'-5 7/8"2'-1 3/4"3 1/2"2'-5 7/8"2'-9 1/4"3 5/8"5'-3 1/4"3 5/8"3'-1 1/4"1'-7 3/8"6"℄DOOR℄DOOR5'-1 7/8"3 1/2"2'-5 7/8"2'-9 1/4"4"3 5/8"3'-1 1/4" 3 1/2"7'-9"3 5/8"6'-6 1/4"3 5/8"5'-2 11/16"5'-0 1/16"3 5/8"1/008 1/012 1/007 1/010 1/006 1/005 1/0021/001 1/009 2'-0"6'-8 15/16"±℄DOOR℄DOOR EXISTINGELEC.001 EXISTINGCOMM.002 REVISEDFREEZER003 MENSLOCKER005 BOILER ROOM009 WHITE WINE + BEER008 MECH007 KITCHEN DRY GOODS012 EXISTINGLIFT FRIDGE004 KITCHEN DRY GOODS010 HALL011 ELEVATOR01 STAIR005 W6A6.01 W10A6.01 W10A6.01 W4A6.01 W8A6.01 W4A6.01 W17A6.03 W8A6.01 W4A6.01 W6AA6.01 EXISTING EXISTING EXISTING EXISTING EXISTING EXISTINGEXISTING EXISTING EXISTING 4/011 VF-1CF-1 VF-1T2 T2 VF-1 VF-1 CF-1 VF-1 CF-1VF-1CF-1CF-1 CF-1 ELEVATOR02 W14A6.02 W10A6.01 W10A6.01 W10A6.01W10A6.01 3"4 5/8"9'-3 5/8"7 5/8"7'-10 13/16"7 5/8"2/010 13'-10 1/8"6'-3 1/4"6'-11 13/16"12'-1 3/8"5'-0 1/2"7 5/8"14'-10 3/8" T.O.S.90'-10 1/4"6"3 5/8"5'-3 1/4"3 5/8"F.O.S. 2" OFFCONC.T WEB F.O.S. 2" OFFCONC.T WEB 4"4'-7 1/4"14'-4 3/4"6"VF-1CF-115'-1 1/2" 4'-0 5/8"3 5/8"1'-10 5/8"8'-10 5/8"℄DOOR4'-4 9/16"9'-10 3/8"6"1'-10 1/8" ℄DOOR FULL HEIGHT WALL TILED LEDGECLOSET UPSTAIR 7 5/8"7 5/8"6"2"6"5 5/8"1 1/2" HAT CHANNEL @FRONT OF PLUMBING SKID& 6" STUD ABOVE SKID W20A6.04 A6.06.13 A6.06.13 W18A6.03 Boiler room must havea 1 hour horizontalassembly above. Firebarrier walls must becontinuous to theunderside of theconcrete deck above.Where is thisdescribed? B C DA 1 2 3 36'-3"34'-11" 89'-10 3/4"32'-9 5/8"60'-10"34'-11" 18'-8 3/4"28'-0 3/8"WORK SPACE STAIRUP 1/102 EXISTINGF.P. (17) TREADS @ 11"(18) RISERS @ 6 3/4" T.O. FINISH100'-0" T.O. FINISH100'-0" T.O. FINISH100'-0" T.O. FINISH100'-0" T.O. FINISH100'-0"T.O. FINISH100'-0" SERVING113 MEADOWS KITCHEN107 EXISTING LIFT OUTDOOR STORAGE108 CHEFS OFFICE110 MECH111 MENSRESTROOM112 OFFICE115 WOMENSRESTROOM114 SERVING106 OFFICE / IT / AV120FIRE121 BERNHARD ROOM102 ELEVATOR02 STAIR05 2/102 1/122 CLOSET122 CLOSET119 ELEVATOR01 1/114 1/112 1/119 1/111 1/107 2/107 3/107 4/107 5/107 1/110 6/107 1/120 4/1053/105 1/108 STORAGE116-A 1/115 6"10" NEW CONCRETE NEW METAL STUD WALL EXISTING CMU NEW CMU EXISTING FRAMED WALL 2 1/4"6"4'-7 15/16"3'-8 3/4"6"11'-5 7/8"7 5/8"6'-3 1/4"7 5/8"℄DOOR 1'-10 1/2"℄DOOR 8'-11 5/8"3'-1 7/16"4'-5 5/8"6"6"1'-4 1/4"7 5/8"8'-10"7 5/8"3/8"6"3 1/2"5'-8 3/8"6"4'-11 3/8"6"6'-5 1/8"32'-9 5/8"6" 6"8'-8 11/16"6" 6"4'-11 13/16"25'-9 5/8"4'-8 3/4"7 5/8" ℄DOOR 8'-2 15/16"6"6"1 13/16"3 5/8"7'-10 1/2"6"6"7'-10 1/2"3 5/8"3 5/8"3 5/8"℄DOOR℄OPENING 1'-10 5/8"℄DOOR12'-7 3/16"3 5/8"1'-10 5/8"2'-11 1/2"6"10'-6 15/16"6"12'-3"7"6"6"9'-7"±7'-9 1/8"3 5/8"1'-9"3'-5 3/8"6"4'-1 5/8"6"5'-10"±℄DOOR4'-11 7/8"1 13/16"7 5/8"5'-11"7 5/8"3'-11 5/16"6"1'-11"9'-6 15/16"ALIGN3 5/8"2'-0 5/8"2'-0 5/8"3 5/8"3'-9 7/16"3 5/8"4'-1 1/4"1 13/16"17'-1 5/8"6"7'-4 5/8"3 5/8"4'-2 5/8"6'-3 7/8"3'-0 5/8"1'-11" ℄DOOR ℄DOOR ℄DOOR ℄DOOR 5 5/8"5/16"2'-8"6"3'-2 1/4"7 5/8"4'-8 1/2"7 5/8"7'-9"5'-2 3/8"3 5/8"7'-9 1/8"±℄DOOR8'-8 1/16" 2'-0 3 / 8 " 3'-9 5 / 8 "℄DOOR1 9/16" 6"1'-11"6'-4"6"3'-9"6"4'-5 1/2"7/8"7 5/8"1/2"1'-11"6" ALIGN 2'-3 1/8"±4'-2 1/8"±6"1 3/4"3 5/8"℄DOOR 8'-8 1/4"3'-11"℄DOOR4'-1 1/4"3 5/8"4'-10"7'-1 3/4"1 9/16"4 7/16" 6"6"6" 6"2 1/4"2 1/4"PLANNORTHSCALE: LOWER LEVEL FLOOR PLAN (NORTH) ENLARGED1/4" = 1'-0"1A2.11 PLANNORTH ℄DOOR ± TYPICAL EXISTINGDINING AREA105 W4A6.01 W3A6.01 W3A6.01 W5A6.01 W5A6.01 W4A6.01 W5A6.01 W4A6.01 W20A6.04 W4A6.01 W4A6.01 W4A6.01 W4A6.01 W17A6.03 W4A6.01 W17A6.03 W14AA6.02 W8A6.01 W14AA6.02 W8A6.01 W4A6.01 W14A6.02 W10A6.01 W15A6.02 W10AA6.01 W10AA6.01 W21A6.04 W3A6.01 W8A6.01 CPT CF-3 CPT CF-2 CF-3 CF-2CF-2 CF-3 CF-2 CF-3 CPT CF-3 CPT CF-3 CPT CPT CPT CPT CPT CF-2 CPT T2 CF-2 T2 T2 CPT CPT CPT CPT CPT CPT CPT CF-3 CF-3 W3A6.01 W3A6.01 W19A6.03 W4A6.01 W14A6.02 STAIR02 1/116-A 2/111 1/121 7 5/8"22'-8"W19A6.03 T.O.S.100'-0" 3 1/2" 6"6'-4 1/4"1'-10"2'-10 1/2"EXISTINGF.P.1'-0"1'-6"4'-0"5'-0"1'-6"1'-0"5'-0"4'-0" 1'-0"4'-0"5'-0"1'-0" 1'-6" 1'-0"4'-0"5'-0"1'-0" 1'-6" 5'-0" 4'-0" 5'-0"4'-0"1'-0"1'-6"1'-0" 1'-6"4'-0"5'-0"1'-6" 1'-0"5'-0"4'-0"1'-6"5'-0" 1'-0" 4'-0 "3 5/8"4'-1 1/4"18'-0 1/2"7'-2 1/4" 1 1/2" HAT CHANNEL@ FRONT OF PLUMBINGSKID & 6" STUD ABOVE SKID W19A6.03 W20A6.04 W20A6.04 1 3/4"3 5/8"1'-9 1/2"3 5/8"3 1/8"1/2"NEW WALL FRAMING@ FIREPLACE SHOULDER A6.06.12 A2.11 1/4" = 1'-0" LOWER LEVEL FLOOR PLAN (NORTH)ENLARGED COPYRIGHT 2018 JEFFREY BERKUS ARCHITECTSTHE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTYOF JEFFREY BERKUS ARCHITECTS. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THEPRIOR WRITTEN PERMISSION OF JEFFREY BERKUS ARCHITECTS. JEFFREY BERKUS ARCHITECTSSHALL RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDINGCOPYRIGHT THERETO. Issue: SHEET TITLE PROJECT NO: DWG FILE:11028_A2-10_Lower Level Plan.dwg SCALE: ASPEN MEADOWS RECEPTION RENOVATION+ PAVILION ADDITION 2017.02.13 400 WEST MAIN STREET - SUITE 205ASPEN, CO 81611PHONE 970.925.7017FAX 970.925.7026 CONSTRUCTION DOCUMENTS / PERMIT2017.03.07REVISED PRICING DRAWING SET2017.06.30FIRST COMMENT RESPONSES2017.06.1475% CONSTRUCTION DOCUMENTS2017.08.17CONSTRUCTION DOCUMENTS2017.12.05CONSTRUCTION DOCUMENTS REVISIONS2018.04.06BUILDING DEPARTMENT - CHANGE ORDER 01 Elevator machineroom mechanicalroom must have 1hour horizontalassembly above andbelow. Fire barrierwalls must becontinuous to theunderside of theconcrete deck above.Where is thisdescribed? Issue: 2017.02.13 JEFFREY BERKU S A R C H I T E C T S 400 WEST MAIN STREET - SUITE 205ASPEN, CO 81611PHONE 970.925.7017FAX 970.925.7026 CONSTRUCTION DOCUMENTS / PERMIT2017.03.07REVISED PRICING DRAWING SET 2017.06.30FIRST COMMENT RESPONSES2017.06.1475% CONSTRUCTION DOCUMENTS2017.08.17CONSTRUCTION DOCUMENTS 2017.12.05CONSTRUCTION DOCUMENTS REVISIONS2018.04.06BUILDING DEPARTMENT - CHANGE ORDER 01 45 minute doorrequired to boiler roomfor 1 hour fire barrierfor incidental use per2015 IBC 716.5. 1 4, 4A 3, 3A 2A9.07 5'-0" MIN.4"3'-0"1'-8"MIRROR ABOVE SPLASH,PER ANSI 2009, TYP. MENSRESTROOM213 1/213 P3 P2b P3b P8 P2 P2a P7 T-1 NOTE: APPLIANCE, FIXTURE ANDPLUMBING SCHEDULE ON A7.03 T. P.℄TILE/PARTITION ℄TILE/DOOR2'-8"1'-8"1'-8"2'-1"EQEQELECTRIC HAND DRIER SCHLUTER TRIM F.D. 1'-6" 6"10"3 5/8"5'-1"A9.07 1/2" = 1'-0" MENS RESTROOM 213 INTERIOR ELEVATIONS COPYRIGHT 2018 JEFFREY BERKUS ARCHITECTSTHE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS THE PROPERTYOF JEFFREY BERKUS ARCHITECTS. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THEPRIOR WRITTEN PERMISSION OF JEFFREY BERKUS ARCHITECTS. JEFFREY BERKUS ARCHITECTSSHALL RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS, INCLUDINGCOPYRIGHT THERETO. SHEET TITLE PROJECT NO: DWG FILE: 11028_A9-01_Interior Elevations.dwg SCALE: ASPEN MEADOWS RECEPTION RENOVATION + PAVILION ADDITION Dimension space between door jamb and lavatory. Must be 18" min per ICCA117.1-2009 section404.2.3.2. Page: [79] A9.07 Interior Elevations File Name: ARCH SET Change Order 2018-04-12.pdf Subject: PlanCheck Author: nickt Color: Dimension the height of the rim of the urinal (17" max per ICC A117.1-2009 section 605.2) Page: 6 File Name: Aspen Meadows Reception Electrical Updated Construction Documents 4-6-2018.pdf Subject: PlanCheck Author: nickt Color: Panel MDP is 1200a. If it is greater than 6' wide, this room will require two means of egress per 2017 NEC 110.26 (C) (2) Aspen Meadows Reception Electrical Updated Construction Documents 4-6-2018.pdf (2) Page: 16 File Name: Aspen Meadows Reception Electrical Updated Construction Documents 4-6-2018.pdf Subject: Heat tape Author: nickt Color: Heat trace/tape must be self-regulating type cable and must include automatic controls and timer capable of turning off the system when the outdoor temperature is above 50 degrees and during daylight hours. (Ordinance 40, 2016). Page: [1] A2.00 Basement Level Floor Plan (Overall) File Name: MEADOWS-Rated_Assemblies_ASI014Rev01_20 17-12-06.pdf Subject: Group Author: nickt Color: This door must be 45 minute rated (2015 IBC 716.5) MEADOWS-Rated_Assemblies_ASI014Rev01_2017-12-06.pdf (9) Page: [1] A2.00 Basement Level Floor Plan (Overall) File Name: MEADOWS-Rated_Assemblies_ASI014Rev01_20 17-12-06.pdf Subject: PlanCheck Author: nickt Color: Elevator connects only 3 floors, requiring only a 1 hour fire rating (2015 IBC 713.4) All of elevator shaft must be 1 hour rated (not 2). 60 minute door required. SCALE: INTERIOR ELEVATION 1/2" = 1'-0" 2 A9.07 OPEN, TYP."17" MAX.13 12" MIN. MIRROR SPLASH TO MATCH COUNTER TOP, TYP. P7 P2a T-3 DW-1 P14 P10 P10 DW-1 TILE WAINSCOT(4 COURSES)P3b P3a 1'-0"2'-0" P6 Dimension the height of the rim of the urinal (17" max per ICCA117.1-2009 section605.2) EF-2 EF-2 BT-1 DHW-1 DHW-2 EF-2 EF-2 B-2 B-1 AHU-3 1 2 A B C FC-3 FC-4 Panel MDP Panel HP EL-1 CU-2E CU-1E SP-1 Panel MDP is 1200a. If it is greater than 6'wide, this room willrequire two means ofegress per 2017 NEC110.26 (C) (2) 1 B C 1 Heat tape to be placed in all downspouts, interior and exterior. DETAIL NOTES THIS SHEET: t = 50W heat tape: 85' x 5W/ft = 425W heat tape GENERAL NOTES THIS SHEET: Roof drains, downspouts, and gutters north of grid 3 still to be determined.Heat tape design is preliminary, to be completed in coordination withroof layout adjustments. Provide heat tape sensors and/or controls to only allow operstion whenmoisture is present and outside air temperatures are below 40F (per IECCSection C403.2.4.5) 1. 2. e ft = 100W heat tape: 26' surface 4' internal~30' total 30' x 5W/ft = 150W Heat trace/tape must be self-regulating typecable and must include automatic controls andtimer capable of turning off the systemwhen the outdoortemperature is above50 degrees and duringdaylight hours.(Ordinance 40, 2016). X.B X.A X.2 X.2 X.1 B C 2 55 A C D D 44 2 11 3 3 A X.B X.A X.2 X.2 X.1 B C 2 55 A C D D 44 2 11 3 3 A UPSTAIR 20'-0" RA M P @ 1 : 1 2 S L O P E M A X . ( 1 ' - 6 1 / 4 " R I S E ) UP ELEC.001 COMM.002 REVISEDFREEZER003MENSLOCKER005 BOILER ROOM009 WHITE WINE + BEER008 MECH007 WOMENSLOCKER006 STAFFBREAK014 KITCHEN DRY GOODS012 HALL011 STORAGE016 HALL015 FRIDGE004 RED WINE + LIQUOR013 CLOSET CLOSET CLOSET16a CLO KITCHEN DRY GOODS010 A2.021 ELEVATOR02 ELEVATOR01 STAIR01 STAIR05 EXISTINGLIFT EXISTING FOOTINGTO REMAIN EXISTING FOOTINGTO REMAIN A2.011 EXISTING FRAMED WALL A6.161 A6.301, 2 & 3 A6.311, 2 & 3 10'-1 1/16"14'-8 5/8"12'-0"8'-6 3 / 4 " 14'-8 5 / 8 " 12'-0 " 3/011 1/008 1/0121/007 1/010 1/006 1/005 1/0021/001 1/009 4/011 2/010 1/016 2/016 3/016 1/011 2/011 1/014 1/013 1/018 Issue: ASPEN ME RECEPTIO + PAVILIO 2017.02.13 JEFFREY A R C H I 400 WEST MAIN ASPE PHONE FAX CONSTRUCT 2017.03.07REVISED PRI 2017.06.30FIRST COMM 2017.06.1475% CONSTR 2017.08.17CONSTRUCT 2017.12.05CONSTRUCT This door must be 45minute rated (2015IBC 716.5) .B BA C D .B BA C D UPSTAIR 20'-0" RAMP @ 1:12 SLOPE MAX. ( 1'-6 1/4" RISE )ELEC.001 COMM.002 REVISEDFREEZER003MENSLOCKER005 BOILER ROOM009 WHITE WINE + BEER008 MECH007 WOMENSLOCKER006 KITCHEN DRY GOODS012 HALL011 FRIDGE004 CLOSET CLOSET KITCHEN DRY GOODS010 ELEVATOR02 ELEVATOR01 STAIR05 EXISTINGLIFT EXISTING FOOTINGTO REMAIN EXISTING FOOTINGTO REMAIN A6.301, 2 & 3 A6.311, 2 & 3 12'-0"12'-0"3/011 1/008 1/012 1/007 1/010 1/006 1/005 1/0021/001 1/009 4/011 2/010 Elevator connects only3 floors, requiring onlya 1 hour fire rating(2015 IBC 713.4)All of elevator shaftmust be 1 hour rated(not 2). 60 minute doorrequired. Page: [1] A2.00 Basement Level Floor Plan (Overall) File Name: MEADOWS-Rated_Assemblies_ASI014Rev01_20 17-12-06.pdf Subject: PlanCheck Author: nickt Color: This door must be 60 minute rated (2015 IBC 716.5) Page: [1] A2.00 Basement Level Floor Plan (Overall) File Name: MEADOWS-Rated_Assemblies_ASI014Rev01_20 17-12-06.pdf Subject: PlanCheck Author: nickt Color: Why are the electric and communications rooms fire rated? Page: [1] A2.00 Basement Level Floor Plan (Overall) File Name: MEADOWS-Rated_Assemblies_ASI014Rev01_20 17-12-06.pdf Subject: PlanCheck Author: nickt Color: Why is this door rated? Page: [2] A2.10 Lower Level Floor Plan (Overall) File Name: MEADOWS-Rated_Assemblies_ASI014Rev01_20 17-12-06.pdf Subject: PlanCheck Author: nickt Color: These doors must be 60 minute rated (2015 IBC 716.5). Page: [2] A2.10 Lower Level Floor Plan (Overall) File Name: MEADOWS-Rated_Assemblies_ASI014Rev01_20 17-12-06.pdf Subject: PlanCheck Author: nickt Color: Rated door not necessary. X.BX.B UPSTAIR 20'-0" RAMP @ 1:12 SLOPE MAX. ( 1'-6 1/4" RISE )ELEC.001 COMM.002 REVISEDFREEZER003MENSLOCKER005 BOILER ROOM009 WHITE WINE + BEER008 MECH007 WOMENSLOCKER006 KITCHEN DRY GOODS012 HALL011 FRIDGE004 RED WINE + LIQUOR013 CLOSET CLOSET KITCHEN DRY GOODS010 ELEVATOR02 ELEVATOR01 STAIR05 EXISTINGLIFT EXISTING FOOTINGTO REMAIN EXISTING FOOTINGTO REMAIN A6.301, 2 & 3 A6.311, 2 & 3 14'-8 5/8"12'-0"14'-8 5/8"12'-0"3/011 1/008 1/012 1/007 1/010 1/006 1/005 1/0021/001 1/009 4/011 2/010 This door must be 60minute rated (2015IBC 716.5) BA C D 2 1 3 BA C D 2 1 3 UPSTAIR MAX. ( 1'- 6 1 / 4 " R I S E ) ELEC.001 COMM.002 REVISEDFREEZER003MENSLOCKER005 BOILER ROOM009 WHITE WINE + BEER008 MECH007 WOMENSLOCKER006 KITCHEN DRY GOODS012 HALL011 FRIDGE004 CLOSET CLOSET KITCHEN DRY GOODS010 ELEVATOR02 ELEVATOR01 STAIR05 EXISTINGLIFT EXISTING FOOTINGTO REMAIN A6.301, 2 & 3 A6.311, 2 & 3 12'-0"12'-0"3/011 1/008 1/012 1/007 1/010 1/006 1/005 1/0021/001 1/009 4/011 2/010 Why are the electricand communicationsrooms fire rated? X.B X.A X.2 5 4 2 1 3 A X.B X.A X.2 5 4 2 1 3 A UPSTAIR 20'-0" R A M P @ 1 : 1 2 S L O P E M A X . ( 1 ' - 6 1 / 4 " R I S E ) UP ELEC.001 COMM.002 REVISEDFREEZER003MENSLOCKER005 BOILER ROOM009 WHITE WINE + BEER008 MECH007 WOMENSLOCKER006 STAFFBREAK014 KITCHEN DRY GOODS012 HALL011 FRIDGE004 RED WINE + LIQUOR013 CLOSET CLOSET CLOSET16a CLO KITCHEN DRY GOODS010 A2.021 ELEVATOR02 ELEVATOR01 STAIR01 STAIR05 EXISTINGLIFT EXISTING FOOTINGTO REMAIN EXISTING FOOTINGTO REMAIN A2.011 A6.161 A6.301, 2 & 3 A6.311, 2 & 3 10'-1 1/16"14'-8 5/8"12'-0"8'-6 3/4"14'-8 5/8"12'-0"3/011 1/008 1/012 1/007 1/010 1/006 1/005 1/0021/001 1/009 4/011 2/010 2/016 3/016 1/011 2/011 1/014 1/013 Why is this doorrated? X.B X.A X.2 B 2 5 A 36'-3"6'-0 1/2"C D 4 34'-11" 1 3 89'-10 3/4"52'-0 3/4"32'-9 5/8"90'-10 7/8"34'-11" 1 A3.031 4.011 A3.022 A4.012 A3.044 A4.021+2 4.032 A4.031 A4.041 2A4.04 A5.012 A3.032A5.021 18'-8 3/4" 6'-9 9/16"A X.B X.A X.2 B 2 5 A 36'-3"6'-0 1/2"C D 4 34'-11" 1 3 89'-10 3/4"52'-0 3/4"32'-9 5/8"90'-10 7/8"34'-11" 1 A3.031 4.011 A3.022 A4.012 A3.044 A4.021+2 4.032 A4.031 A4.041 2A4.04 A5.012 A3.032A5.021 18'-8 3/4" 6'-9 9/16"A WORK SPACE UP STAINLESS STEELSINKSSTACCATOK-3361-4 UPSTAIR DN UP X.B X.A X.2 B 2 5 A 36'-3"6'-0 1/2"C D 4 34'-11" 1 3 89'-10 3/4"52'-0 3/4"32'-9 5/8"90'-10 7/8"34'-11" 1 A3.031 4.011 A3.022 A4.012 A3.044 A4.021+2 4.032 A4.031 A4.041 2A4.04 A5.012 A3.032A5.021 18'-8 3/4" 6'-9 9/16"A ENTRY SERVING103 SERVING113 MEADOWS KITCHEN107 EXISTINGLIFT OUTDOOR STORAGE108 CHEFSOFFICE110 MECH111 MENSRESTROOM112 OFFICE115 CORRIDOR116 WOMENSRESTROOM114 EXISTINGF.P. SERVING106 ENTRY LOBBY117 NEW DECK109 OFFICE / IT / AV120 LINE OF NEW PEDESTRIANRAMP ABOVE FIRE121 EXISTINGDINING AREA104 BERNHARD ROOM102 A2.121 A2.111 ELEVATOR02 ELEVATOR01 CLOSET119 CLOSET122 STAIR01 STOR. STAIR05 STAIR03 STAIR02 EXISTINGF.P.HOST101 STAIR06 A6.161 A6.301, 2 & 3 A6.311, 2 & 3 A6.131 STOR.116-A 1/102 2/102 1/122 1/114 1/112 1/119 1/111 1/107 2/107 3/107 4/107 5/107 1/110 6/107 1/120 4/1053/105 1/108 1/115 1/116-A 2/111 2/103 1/117 2/117 3/117 4/117 1/104 1/103 1/121 EXISTINGDINING AREA105 Issue: ASPEN MEADOW RECEPTION REN + PAVILION ADD 2017.02.13 JEFFREY BERKU A R C H I T E C T 400 WEST MAIN STREE ASPEN, CO 8 PHONE 970.92 FAX 970.925 CONSTRUCTION DOC 2017.03.07REVISED PRICING DR 2017.06.30FIRST COMMENT RES 2017.06.1475% CONSTRUCTION 2017.08.17CONSTRUCTION DOC 2017.12.05CONSTRUCTION DOC These doors must be60 minute rated (2015IBC 716.5). X.B X.A X.2 .1 B C 5 A 36'-3"90'-10 7/8"C D D 4 2 6'-0 1/2"24'-0 3/8"34'-11" 1 3 89'-10 3/4"28'-0 3/8"32'-9 5/8"34'-11" A3.011+2 A4.011 A3.021 A3.022 A4.012 A3.044 A4.021+2 4.032 A4.031 A4.041 2A4.04 A5.012 A3.032A5.021 18'-8 3/4" 6'-9 9/16"14'-9 3/16"A 1 39 X.B X.A X.2 .1 B C 5 A 36'-3"90'-10 7/8"C D D 4 2 6'-0 1/2"24'-0 3/8"34'-11" 1 3 89'-10 3/4"28'-0 3/8"32'-9 5/8"34'-11" A3.011+2 A4.011 A3.021 A3.022 A4.012 A3.044 A4.021+2 4.032 A4.031 A4.041 2A4.04 A5.012 A3.032A5.021 18'-8 3/4" 6'-9 9/16"14'-9 3/16"A 1 39 WORK SPACE UP STAINLESS STEELSINKSSTACCATOK-3361-4 UPSTAIR DN UP X.B X.A X.2 .1 B C 5 A 36'-3"90'-10 7/8"C D D 4 2 6'-0 1/2"24'-0 3/8"34'-11" 1 3 89'-10 3/4"28'-0 3/8"32'-9 5/8"34'-11" A3.011+2 A4.011 A3.021 A3.022 A4.012 A3.044 A4.021+2 4.032 A4.031 A4.041 2A4.04 A5.012 A3.032A5.021 18'-8 3/4" 6'-9 9/16"14'-9 3/16"A 1 39 ENTRY SERVING103 SERVING113 MEADOWS KITCHEN107 EXISTINGLIFT OUTDOOR STORAGE108 CHEFSOFFICE110 MECH111 MENSRESTROOM112 OFFICE115 CORRIDOR116 WOMENSRESTROOM114 EXISTINGF.P. SERVING106 ENTRY LOBBY117 NEW DECK109 OFFICE / IT / AV120 LINE OF NEW PEDESTRIANRAMP ABOVE FIRE121 EXISTINGDINING AREA104 BERNHARD ROOM102 A2.121 A2.111 ELEVATOR02 ELEVATOR01 CLOSET119 CLOSET122 STAIR01 STOR. STAIR05 STAIR03 STAIR02 EXISTINGF.P.HOST101 STAIR06 A6.161 A6.301, 2 & 3 A6.311, 2 & 3 A6.131 STOR.116-A 1/102 2/102 1/122 1/114 1/112 1/119 1/111 1/107 2/107 3/107 4/107 5/107 1/110 6/107 1/120 4/1053/105 1/108 1/115 1/116-A 2/111 2/103 1/117 2/117 3/117 4/117 1/104 1/103 1/121 EXISTINGDINING AREA105 Rated door notnecessary. Page: [2] A2.10 Lower Level Floor Plan (Overall) File Name: MEADOWS-Rated_Assemblies_ASI014Rev01_20 17-12-06.pdf Subject: PlanCheck Author: nickt Color: Pick up changes from the fire rated assemblies sheets into the rest of the plans. Also, it would be helpful to add these fire resistive sheets to the architectural set. Page: [2] A2.10 Lower Level Floor Plan (Overall) File Name: MEADOWS-Rated_Assemblies_ASI014Rev01_20 17-12-06.pdf Subject: PlanCheck Author: nickt Color: All of the elevator shaft must be 1 hour rated (not 2). 60 minute door required. D 11" 1 32'-9 5/8"D 11" 1 32'-9 5/8"STAINLESS STEELSTACCATOK-3361-4 D 11" 1 32'-9 5/8"A2.111 400 W Pick up changes from the fire ratedassemblies sheets into the rest of the plans. Also, it would be helpful to add these fire resistive sheets to thearchitectural set. X.B X.A X.3 X.2 X.2 X.1 B C 2 5 A 36'-3"6'-0 1/2"90'-10 7/8"C D D 4 6'-0 1/2"24'-0 3/8"34'-11" 1 3 89'-10 3/4"28'-0 3/8"32'-9 5/8"52'-0 3/4"32'-9 5/8"90'-10 7/8"34'-11" A3.021 A3.031 4.011 A3.022 A4.012 A3.042 A3.043 A3.044 A4.021+2 4.032 A4.031 A4.041 A4.041 2A4.04 A5.012 A3.032A5.021 18'-8 3/4" 6'-9 9/16"14'-9 3/16"A 10'- 4 " 39' - 0 " X.B X.A X.3 X.2 X.2 X.1 B C 2 5 A 36'-3"6'-0 1/2"90'-10 7/8"C D D 4 6'-0 1/2"24'-0 3/8"34'-11" 1 3 89'-10 3/4"28'-0 3/8"32'-9 5/8"52'-0 3/4"32'-9 5/8"90'-10 7/8"34'-11" A3.021 A3.031 4.011 A3.022 A4.012 A3.042 A3.043 A3.044 A4.021+2 4.032 A4.031 A4.041 A4.041 2A4.04 A5.012 A3.032A5.021 18'-8 3/4" 6'-9 9/16"14'-9 3/16"A 10'- 4 " 39' - 0 " WORK SPACE UP STAINLESS STEELSINKSSTACCATOK-3361-4 UPSTAIR DN UP X.B X.A X.3 X.2 X.2 X.1 B C 2 5 A 36'-3"6'-0 1/2"90'-10 7/8"C D D 4 6'-0 1/2"24'-0 3/8"34'-11" 1 3 89'-10 3/4"28'-0 3/8"32'-9 5/8"52'-0 3/4"32'-9 5/8"90'-10 7/8"34'-11" A3.021 A3.031 4.011 A3.022 A4.012 A3.042 A3.043 A3.044 A4.021+2 4.032 A4.031 A4.041 A4.041 2A4.04 A5.012 A3.032A5.021 18'-8 3/4" 6'-9 9/16"14'-9 3/16"A 10'- 4 " 39' - 0 " ENTRY SERVING103 SERVING113 MEADOWS KITCHEN107 EXISTINGLIFT OUTDOOR STORAGE108 CHEFSOFFICE110 MECH111 MENSRESTROOM112 OFFICE115 CORRIDOR116 WOMENSRESTROOM114 EXISTINGF.P. SERVING106 ENTRY LOBBY117 DINING AREA118 NEW DECK109 OFFICE / IT / AV120 LINE OF NEW PEDESTRIANRAMP ABOVE FIRE121 EXISTINGDINING AREA104 BERNHARD ROOM102 A2.121 A2.111 ELEVATOR02 ELEVATOR01 CLOSET119 CLOSET122 STAIR01 STOR. STAIR05 STAIR03 STAIR02 EXISTINGF.P.HOST101 LINE OF SKYLIGHT ABOVE STAIR06 NEW CONCRETE EXISTING FRAMED WALL A6.161 A6.301, 2 & 3 A6.311, 2 & 3 A6.131 STOR.116-A 1/102 2/102 1/122 1/114 1/112 1/119 1/111 1/107 2/107 3/107 4/107 5/107 1/110 6/107 1/120 4/1053/105 1/108 1/115 1/116-A 2/111 2/103 1/117 2/117 3/117 4/117 1/104 1/118 6/118 1/103 1/121 EXISTINGDINING AREA105 Issue: ASPEN MEADOWSRECEPTION RENOVATION+ PAVILION ADDITION 2017.02.13 JEFFREY BERKU SA R C H I T E C T S 400 WEST MAIN STREET - SUITE 120ASPEN, CO 81611PHONE 970.925.7017FAX 970.925.7026 CONSTRUCTION DOCUMENTS / PERMIT2017.03.07REVISED PRICING DRAWING SET2017.06.30FIRST COMMENT RESPONSES2017.06.1475% CONSTRUCTION DOCUMENTS2017.08.17CONSTRUCTION DOCUMENTS2017.12.05CONSTRUCTION DOCUMENTS REVISION All of the elevatorshaft must be 1 hourrated (not 2). 60minute door required.