HomeMy WebLinkAboutFile Documents.845 Meadows Rd.0048.2018 (11).ACBKI'V110111VIII1111r, 4" MIN TO TOP CEIUNG'MOUNTED MIN' 6" SPRINKLER HEAD Label Description Suggested Wire Type 12" MAX TO BOTTOM SMOKE DETECTOR MEASURE FROM TOP OF DEVICE ® AC 120VAC Power Wiring 3#12 AWG Solid (w/Ground) OP ® ❑Q WALL MOUNTED AUDIBLE DEVICE - DRY SIDEWALL, CHROME L Signaling Line Circuit #18 AWG Twisted Pair Sprinkler Pipe NOTE: PR NKLERRCONTRACTOR SUBJECT TO APPROVALS BYLARCHITECTS CHOSEN THE ENGINEER. COORDINATE TYPE AND FINISH WITH INTERIORS. HEADS SHALL BE LISTED FOR RESIDENTIAL USE IN RESIDENTIAL UNITS. ALL HEADS SHALL BE QUICK RESPONSE. P 24VDC Power Wiring 2#14 AWG Solid WALL MOUNTED 96" MAX (TOP OF LENS) Duct Detector N Notification Appliance (Strobe) Wiring 2#14 AWG Solid SMOKE DETECTOR d 0 WALL MOUNTED VISUAL OR AUDIBLE/VISUAL DEVICE V Notification Appliance (Speaker) Wiring 2#16 AWG Solid Strobe 80" MIN BOTTOM OF LENS X Auxiliary Circuit (Relay) Wiring 2#14 AWG Solid Weatherproof Speaker/Strobe NOTLESS THAN •-�-" Z Indicating Device Circuit (Zone) Wiring 2#16 AWG Solid 90" ABOVE A Annunciator Wiring 2#18 AWG Solid Carbon Monoxide Detector I MEASURE TO TOP OF CABINET ENTIRE LENS SHALL BE WITHIN 80"-96" MEASURE TO TOP OF UNIT 72" STANDARD MOUNTING HEIGHT DETAIL NOT TO SCALE 64"-68" EF -A-71 FIRE ALARM CONTROL PANEL LCD LCD ANNUNCIATOR TO CENTER OF DEVICE ❑F MANUAL PULL STATION 42"-48" ALL HEIGHTS MEASURED FROM FINISHED FLOOR MOUNTING HEIGHT NOTES: 1. MOUNTING HEIGHTS ARE PER NEPA 72 AND ADA ACCESSIBILITY GUIDELINES. 2. REMOTE LIGHTS AND REMOTE TEST STATIONS SHALL BE MOUNTED ON THE WALL BELOW ITS ASSOCIATED DEVICE & SHALL BE CLEARLY VISIBLE. 3. ADDRESSABLE MODULES SHALL BE MOUNTED AS TO BE ACCESSIBLE. 4. IN ADA UNITS, 110CD STROBES MUST BE MOUNTED 24" BELOW THE CEILING. 5. MOUNT EXTERIOR HORN/STROBES 10' ABOVE FIRE DEPARTMENT CONNECTION. FIRE ALARM GENERAL NOTES 1. THIS BUILDING SHALL BE PROVIDED WITH AN ADDRESSABLE FIRE ALARM SYSTEM, DESIGNED, INSTALLED AND TESTED PER NFPA 72 REQUIREMENTS AND PER THE AUTHORITY HAVING JURISDICTION. 2. OCCUPANT NOTIFICATION IS THROUGH VOICE EVACUATION. 3. DESIGN CRITERIA INCLUDES FULL COVERAGE SMOKE DETECTION. IN AREAS NOT SUITABLE FOR SMOKE DETECTION (I.E. KITCHENS, BATHROOMS), HEAT DETECTORS ARE NOT NECESSARY DUE TO PRESENCE OF SPRINKLER HEADS. 4. ALL EQUIPMENT USED ON THIS PROJECT SHALL BE UL LISTED FOR USE IN FIRE ALARM SYSTEMS. 5. FIRE ALARM DEVICES SHALL BE COORDINATED WITH ALL LIGHTING FIXTURES AND CEILING SYSTEMS. 6. PROVIDING CONDUIT AND WIRING TO FDC FROM WATER ENTRY ROOM FOR OUTSIDE HORN/STROBE. 7. PLANS ARE CONCEPTUAL ONLY. FIRE ALARM CONTRACTOR SHALL REFER TO SPECIFICATIONS AND APPLICABLE CODES AND STANDARDS. 8. CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR SUBMITTAL TO THE AUTHORITY HAVING JURISDICTION, OWNER AND ARCHITECT BEFORE BEGINNING WORK. 9. CONTRACTOR SHALL TAKE NO ADVANTAGE OF ANY APPARENT ERROR OR OMISSION AND SHALL IMMEDIATELY NOTIFY ARCHITECT. ARCHITECT WILL THEN MAKE SUCH CORRECTIONS AND/OR INTERPRETATIONS AS MAY BE NECESSARY FOR FULFILLING INTENT OF PLANS AND SPECIFICATIONS. 10. COORDINATE ALL WORK WITH OTHER TRADES. 11. PROVIDE OWNER WITH THE NECESSARY INSTRUCTION MANUALS FOR THE UPKEEP OF THE SYSTEM. 12. INSTALL ONLY NEW EQUIPMENT AND WIRING. 13. COORDINATE FIRE ALARM REQUIREMENTS FOR MONITORING WATERFLOW AND TAMPER SWITCHES WITH THE FIRE PROTECTION CONTRACTOR. 14. UPON COMPLETION, FIRE PROTECTION CONTRACTOR SHALL PROVIDE AS -BUILT, RED -LINED DRAWINGS DEPICTING ACCURATE SYSTEM INSTALLATION. 15. FIRE ALARM CONTRACTOR SHALL PROVIDE A MATERIAL SUBMITTAL FOR ALL EQUIPMENT AND WIRING TO BE INSTALLED AS PART OF THEIR SUBMITTAL. FIRE PROTECTION GENERAL NOTES 1. THIS BUILDING IS TO BE PROVIDED WITH A FIRE SPRINKLER SYSTEM DESIGNED, INSTALLED AND TESTED PER NFPA 13 REQUIREMENTS AND IN ACCORDANCE WITH THE AUTHORITY HAVING JURISDICTION. 2. THE EXISTING BUILDING IS CURRENTLY SPRINKLERED. THE EXISTING WATER SUPPLY AND FIRE SPRINKLER ENTRY IS SIZED TO SUFFICIENTLY HANDLE THE REMODEL. BASED ON TEST & INSPECTION REPORTS, THE EXISTING PRESSURE IS 135 PSI STATIC AND 110 PSI RESIDUAL. 3. ALL MATERIALS, DEVICES AND HANGERS USED ON THIS PROJECT SHALL BE UL LISTED FOR USE IN FIRE PROTECTION SYSTEMS. 4. ALL PIPING SHALL COMPLY WITH PROJECT SPECIFICATIONS. PIPE SIZING IS TO BE COMPLETED BY THE FIRE PROTECTION CONTRACTOR, PROVEN BY HYDRAULIC CALCULATIONS, IN ACCORDANCE WITH NFPA 13. 5. FREEZE PROTECTION IS THE RESPONSIBILITY OF THE OWNER IN AREAS WHERE AN ANTI -FREEZE OR DRY SYSTEM ARE NOT INSTALLED. FIRE PROTECTION CONTRACTOR SHALL VERIFY CONDITIONED TEMPERATURE OF ALL AREAS PRIOR TO SYSTEM DESIGN. 6. THE OWNER SHALL MAINTAIN A CLEAR 18" BETWEEN THE CEILING AND THE TOP OF ANY STORAGE OR OTHER OBSTRUCTIONS. 7. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 8. SPRINKLER HEADS TO BE COORDINATED WITH ALL LIGHTING FIXTURES AND CEILING SYSTEMS. 9. OFFSET PIPING, DUCTWORK, ETC. AS NECESSARY TO ACCOMMODATE STRUCTURE, BEAMS, COLUMNS, AND EXISTING EQUIPMENT. 10. PLANS ARE CONCEPTUAL ONLY. SPRINKLER CONTRACTOR SHALL REFER TO SPECIFICATIONS AND PREPARE SHOP DRAWINGS FOR SUBMITTAL TO THE AUTHORITY HAVING JURISDICTION, OWNER AND ARCHITECT BEFORE ANY PIPE IS HUNG. 11. CONTRACTOR SHALL TAKE NO ADVANTAGE OF ANY APPARENT ERROR OR OMISSION AND SHALL IMMEDIATELY NOTIFY ARCHITECT. ARCHITECT WILL THEN MAKE SUCH CORRECTIONS AND/OR INTERPRETATIONS AS MAY BE NECESSARY FOR FULFILLING INTENT OF PLANS AND SPECIFICATIONS. 12. COORDINATE ALL WORK WITH OTHER TRADES. 13. PROVIDE OWNER WITH THE NECESSARY INSTRUCTION MANUALS FOR THE UPKEEP OF THE SYSTEM. 14. INSTALL ONLY NEW SPRINKLERS AND MATERIALS. 15. FIRESTOP ALL PENETRATIONS OF SMOKE/FIRE WALLS, CEILINGS, FLOORS, ROOFS, ETC. TO MAINTAIN FIRE RATING. 16. PROVIDE ACCESS PANELS TO ALL VALVES LOCATED ABOVE NON -ACCESSIBLE CEILINGS AND CHASES. 17. HYDROSTATICALLY TEST ALL SYSTEM PIPING AT 200 PSI FOR TWO HOURS OR AT 50 PSI ABOVE SYSTEM OPERATING PRESSURE, WHICHEVER IS GREATER. 18. PROVIDE A STOCK OF SPARE SPRINKLERS OF EACH STYLE, TYPE AND TEMPERATURE RATING, ALONG WITH A SPRINKLER WRENCH OF EACH STYLE, AT THE MAIN RISER. 19. COORDINATE FIRE ALARM REQUIREMENTS FOR MONITORING WATERFLOW AND TAMPER SWITCHES WITH THE FIRE ALARM CONTRACTOR. 20. COORDINATE THE LOCATIONS OF AUXILIARY DRAINS WITH THE ARCHITECT. 21. UPON COMPLETION, FIRE PROTECTION CONTRACTOR SHALL PROVIDE AS -BUILT, RED -LINED DRAWINGS SHOWING ANY REVISIONS TO THE SUBMITTED PIPING SYSTEM INCLUDING THE LOCATIONS OF ALL DRAINS AND VALVES INSTALLED DURING THE INSTALLATION OF THE PIPING. 22. SPRINKLER CONTRACTOR SHALL PROVIDE A MATERIAL SUBMITTAL FOR PIPE, SPRINKLER HEADS, VALVES AND OTHER MATERIAL AS PART OF THEIR SUBMITTAL. 23. SPRINKLER CONTRACTOR SHALL INCLUDE HYDRAULIC DESIGN INFORMATION AS PART OF THEIR SUBMITTAL INCLUDING HYDRAULIC CALCULATIONS AND PIPE SIZES. 24. PIPE SHALL BE CONCEALED TO THE EXTENT POSSIBLE. 25. CPVC PIPE IS NOT ALLOWED. PIPING SHALL BE STEEL OR COPPER. 1. NO T -TAPPING PERMITTED ON ANY CIRCUIT, UNLESS ALLOWED BY MANUFACTURER. 2. WIRING SHALL BE IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. ( SYSTEM RISER DIAGRAM SPRINKLER TYPES/PIPE NOTES: 1. CPVC PIPING IS NOT ALLOWED. PROVIDE STEEL PIPING, PAINTED TO MATCH INTERIORS. 2. PROVIDE CONCEALED SPRINKELR HEADS IN AREAS WITH FINISHED CEILINGS. COORDINATE ESCUTSCHEON COLOR WITH INTERIORS. 3. PROVIDE UPRIGHT OR PENDENT HEADS IN AREAS WITH EXPOSED STRUCTURE. 120V o �Q D a o v o D 0 v D G o ° p WATER SERVICE. REFER TO CIVIL ° n DRAWINGS FOR CONTINUATION. D ° 0 n EXTERIOR WALL 0 o O D D D I o p V a D G o WATER & FIRE ENTRY DIAGRAM N ALE BALL DRIP VALVE. DOMESTIC WATER / PIPE FLANGE PIPE SLEEVE / LARGER THAN O.D. OF PIPE p o D O D o p p o FLOOR SLAB EXTERIOR BLDG. WALL. TO FIRE SPRINKLERS flRE DEPT. CONNEC'no TEST VALVE; PIP 0 OUTSIDE. RINKER WATERFLOW SWITCH DRAIN VALVE; PIPE FLOOR DRAIN, DOUBLE CHECK TYPE 4" IN j�l-- I TAMPER SWITCHES ON BVALVES.ACKFLOW PREVENTER. FIRE ENTRY PIPING DIAGRAM NO SCALE FIRE PROTECTION LEGEND: SYMBOL DEVICE DESCRIPTION I� SPRINKLER HEAD - STANDARD UPRIGHT, CHROME ® SPRINKLER HEAD - RECESSED PENDENT ® SPRINKLER HEAD - RECESSED SIDEWALL ® SPRINKLER HEAD - DRY SIDEWALL, CHROME Sprinkler Pipe NOTE: PR NKLERRCONTRACTOR SUBJECT TO APPROVALS BYLARCHITECTS CHOSEN THE ENGINEER. COORDINATE TYPE AND FINISH WITH INTERIORS. HEADS SHALL BE LISTED FOR RESIDENTIAL USE IN RESIDENTIAL UNITS. ALL HEADS SHALL BE QUICK RESPONSE. FIRE ALARM LEGEND: SYMBOL DEVICE DESCRIPTION FRCP Fire Alarm Control Panel ❑F Manual Pull Station uu Monitor Module OF Photoelectric Smoke Detector ie U Heat Detector Duct Detector Speaker/Strobe Z O Strobe wTv��I ✓ISI Weatherproof Speaker/Strobe •-�-" Sprinkler Waterflow Switch Sprinkler Valve Tamper Switch Carbon Monoxide Detector 0 a ie U W 0 Z O y K W d Z N 00 O 00 01 0 0> o T _ CD r, T W 4-f O 0 LL ® 1 L d sJ • ` 1 • CD L 0 00 O 0 n 0 o O U x O U DO N O a L� z O F____ Q Q LJ Z CL O J LU a Q Of J (/i Z Q = O LU < O m C/) O Z LU z -0 0 Q of U W m LUz 2 F---� ED z z: z d a- LLI LU a- U LU N (n LU - of LU Q j]f L 0 SHEET DESCRIPTION: FIRE ALARM & FIRE PROTECTION COVER SHEET DATE: 2/27/,17 L L I ISSUE: FOR PERMIT SHEET#: F-0.0 FIRE ALARM NOTES: 1. FIRE ALARM SYSTEM SHALL BE DESIGNED PER NFPA 72 AND ASPEN FIRE PROTECTION DISTRICT REQUIREMENTS. 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE LOCATIONS, SYSTEM DESIGN AND INSTALLATION. 3. FIRE ALARM CONTROL PANEL SHALL BE ADDRESSABLE, NETWORK CAPABLE AND HAVE VOICE EVACUATION CAPABILITIES. CONNECT TO CAMPUS FIRE ALARM NETWORK (REFER TO SITE WIDE FIRE ALARM SYSTEM UPGRADE SCOPE). 4. MONITOR WATERFLOW & TAMPER SWITCHES FOR SPRINKLER SYSTEM. COORDINATE WITH FIRE PROTECTION CONTRACTOR. 5. PROVIDE AN ELECTRONIC COPY OF THE SHOP DRAWINGS AND EQUIPMENT SUBMITTALS TO ARCHITECT AND FIRE PROTECTION ENGINEER FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO AUTHORITY HAVING JURISDICTION. FIRE PROTECTION NOTES: 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13 AND ASPEN FIRE PROTECTION DISTRICT REQUIREMENTS. 2. SPRINKLERS SHOWN ON THESE PLANS ARE EXISTING TO REMAIN. IN OTHER AREAS, NEW SPRINKLER HEADS SHALL BE INSTALLED PER NFPA 13 STANDARDS. 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER SYSTEM DESIGN AND INSTALLATION. 4. PROVIDE ELECTRONIC COPIES OF SHOP DRAWINGS AND EQUIPMENT SUBMITTALS TO ARCHITECT AND FIRE PROTECTION ENGINEER FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO AUTHORITY HAVING JURISDICTION. 5. PER ARCHITECTURAL PLANS, THERE ARE NO COMBUSTIBLE CONCEALED SPACES REQUIRING SPRINKLER PROTECTION. 6. PER ARCHITECTURAL PLANS, THERE ARE NO COMBUSTIBLE OVERHANGS REQUIRING EXTERIOR SPRINKLER PROTECTION. 7. COORDINATE FREEZE PROTECTION WITH GENERAL CONTRACTOR. 8. CPVC PIPING IS NOT ALLOWED. PIPING SHALL BE STEEL OR COPPER. FLAG NOTES O LOCATION OF EXISTING 4" FIRE SPRINKLER WATER ENTRY. PROVIDE BACKFLOW PREVENTER, WATERFLOW AND TAMPER SWITCH AND OTHER ACCESSORIES REQUIRED BY NFPA 13. O PROPOSED LOCATION OF FIRE DEPARTMENT CONNECTION. VERIFY LOCATION WITH ASPEN FIRE PROTECTION DISTRICT. O3 COORDINATE NUMBER AND LOCATION OF FLOW/TAMPER SWITCHES WITH FIRE PROTECTION CONTRACTOR. O4 PROVIDE SMOKE DETECTOR, HEAT DETECTOR AND MODULES TO ACHIEVE ELEVATOR RECALL, SHUNT TRIP, HAT LIGHT AND SHUNT TRIP MONITORING IN ELEVATOR EQUIPMENT ROOM. OS FIRE ALARM CONTROL PANEL WITH VOICE EVACUATION. PROVIDE LCD DISPLAY AND MICROPHONE ALONG WITH ADEQUATE AMPLIFIERS TO ACCOMMODATE FUTURE TENANT BUILDOUTS. PROVIDE LIGHT HA. SPRINKLER COVER] LOCKER AREAS. O F a a U W a z 0 w a z z N 00 O 00 0) 0 0> o T _ CD r, rn rn 4-! 0 0 I L ® 1 L O_ (V^ ` 1 • CD O 00O 0 n O O O U x O U M N O Of tL � z O Q LL Z L O W 0 _ 06 J C/) Z Q O � 11"Q O > LL. z m U)O O_ 0 O w F- M w m Q z Lu O O 0w z 0 L U Lu N Cn Lu Q 0,, LL LL I 0 SHEET DESCRIPTION: FIRE ALARM & FIRE PROTECTION BASEMENT DATE: 2/27/17 L ISSUE: FOR PERMIT SHEET#: F-1.0 FIRE ALARM NOTES: 1. FIRE ALARM SYSTEM SHALL BE DESIGNED PER NFPA 72 AND ASPEN FIRE PROTECTION DISTRICT REQUIREMENTS. 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE LOCATIONS, SYSTEM DESIGN AND INSTALLATION. 3. FIRE ALARM CONTROL PANEL SHALL BE ADDRESSABLE, NETWORK CAPABLE AND HAVE VOICE EVACUATION CAPABILITIES. CONNECT TO CAMPUS FIRE ALARM NETWORK (REFER TO SITE WIDE FIRE ALARM SYSTEM UPGRADE SCOPE). 4. MONITOR WATERFLOW & TAMPER SWITCHES FOR SPRINKLER SYSTEM. COORDINATE WITH FIRE PROTECTION CONTRACTOR. 5. PROVIDE AN ELECTRONIC COPY OF THE SHOP DRAWINGS AND EQUIPMENT SUBMITTALS TO ARCHITECT AND FIRE PROTECTION ENGINEER FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO AUTHORITY HAVING JURISDICTION. FIRE PROTECTION NOTES: 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13 AND ASPEN FIRE PROTECTION DISTRICT REQUIREMENTS. 2. SPRINKLERS SHOWN ON THESE PLANS ARE EXISTING TO REMAIN. IN OTHER AREAS, NEW SPRINKLER HEADS SHALL BE INSTALLED PER NFPA 13 STANDARDS. 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER SYSTEM DESIGN AND INSTALLATION. 4. PROVIDE ELECTRONIC COPIES OF SHOP DRAWINGS AND EQUIPMENT SUBMITTALS TO ARCHITECT AND FIRE PROTECTION ENGINEER FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO AUTHORITY HAVING JURISDICTION. 5. PER ARCHITECTURAL PLANS, THERE ARE NO COMBUSTIBLE CONCEALED SPACES REQUIRING SPRINKLER PROTECTION. 6. PER ARCHITECTURAL PLANS, THERE ARE NO COMBUSTIBLE OVERHANGS REQUIRING EXTERIOR SPRINKLER PROTECTION. 7. COORDINATE FREEZE PROTECTION WITH GENERAL CONTRACTOR. 8. CPVC PIPING IS NOT ALLOWED. PIPING SHALL BE STEEL OR COPPER. FLAG NOTES O LOCATION OF EXISTING 4" FIRE SPRINKLER WATER ENTRY. PROVIDE BACKFLOW PREVENTER, WATERFLOW AND TAMPER SWITCH AND OTHER ACCESSORIES REQUIRED BY NFPA 13. O2 PROPOSED LOCATION OF FIRE DEPARTMENT CONNECTION. VERIFY LOCATION WITH ASPEN FIRE PROTECTION DISTRICT. O COORDINATE NUMBER AND LOCATION OF FLOW/TAMPER SWITCHES WITH FIRE PROTECTION CONTRACTOR. Oa PROVIDE SMOKE DETECTOR, HEAT DETECTOR AND MODULES TO ACHIEVE ELEVATOR RECALL, SHUNT TRIP, HAT LIGHT AND SHUNT TRIP MONITORING IN ELEVATOR EQUIPMENT ROOM. O5 FIRE ALARM CONTROL PANEL WITH VOICE EVACUATION. PROVIDE LCD DISPLAY AND MICROPHONE ALONG WITH ADEQUATE AMPLIFIERS TO ACCOMMODATE FUTURE TENANT BUILDOUTS. PROVIDE ORDINARY HAZARD, GROUP 2 NFPA 13 SPRINKLER COVERAGE THROUGHOUT KITCHEN, COOKING AND RESTAURANT SERVICE AREAS. EXISTING 105 -------------------� mwP ============= OP --------------------- APPROXIMATE LOCATION OF EXISTING NOTIFIER FIRE ALARM CONTROL PANEL. DURING CONSTRUCTION THIS PANEL MUST REMAIN OPERATIONAL. ° ' r SII III �II � � � � L T � � � �� III II IIII III IIII IIII IIII IIII IIII IIII III -- — — — —_ — —— e' -a O II II I III O 8'�" III O III AhNHAND 3061A IIII II_ _ _ _ _��_ F.C. IIII III IIII III F.C. IIII III IIII B' -a" III II Ili IIII IIII IIII IIII III — — — — — III III F.C. III III III III III III EkISTINGI III III III IIII III----�----- I II IID? p II III DINING AREA IIII III IIII IQ? IIID IIII SEG-- IIII IIII IIII IIII 11� I IIII III IIII I P II IIII IIII III IIII III IIII IIII III=====_____ III r7A.III IIII III IIII I III _ IIII 01 III I F II IIL10— IIII F ==----=— I IIII IIII IIII IIII I I IIII III IIII I ----- I IIII II IIII IIII I I IIII III IIII I — — --- SPRINKLER AND FIRE ALARM DEVICES IN DINING L J J — — L JIIL JI I \ 104/105 ARE EXISTING. REWORK FIRE ALARM \ DEVICES TO NEW DESIGN. CONVERT EXISTING III L — — — — — F HORN/STROBES TO SPEAKER/STROBES. SPRINKLER HEADS AND PIPING ARE EXISTING TO REMAIN. J I I ENTRY \ L ENTRY LOBBY / U 11A I , % 7-312" F.C. 00P \ \ I DN I I l0 \\ \ DINING AREA \ \ 10'-0" F.C. I L I F \ - \\ �P 1 \\ PROVIDE L%1oTVH=tFiQ NFPA X1`3 `\ 0 1 I SPRINKLERETHROuGF}QUT \ \ RESTAURANEATING AREAS. \- 13013 \ 1 IL ? `\ \ 13OP \ \\ lL ` \ 00 P NORTH \ \ \ \ ` LOWER LEVEL FLOOR PLAN SCALE: 1/8" = 1'D" 0 a U W 0 z 0 y A x w 0 O z N 00 O 00 0) 0 0> O T _ O^ rn rn 4-I 0 0 L, ® 1 L O_ (V^ ^` 1 • CD O 00O 0 r O O O U x 6 O U M N O Of a Z O F— m Q Lu Z � O W 0 _ 06 J F) Z Q O QLL O m O Z Lu 0 Q Lu F- 0 } IL m Q Z 11-11-1O C) LU � � Z Z U LU LU 0- U N Cn Lu Q CL' gJ Li Lu SHEET DESCRIPTION: FIRE ALARM & FIRE PROTECTION LOWER LEVEL DATE: 7 2/27/1 L LI II ISSUE: FOR PERMIT SHEET#: F-1.1 FIRE ALARM NOTES: 1. FIRE ALARM SYSTEM SHALL BE DESIGNED PER NFPA 72 AND ASPEN FIRE PROTECTION DISTRICT REQUIREMENTS. 2. DEVICE LOCATIONS AND WIRING ARE SCHEMATIC ONLY AND ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR DEVICE LOCATIONS, SYSTEM DESIGN AND INSTALLATION. 3. FIRE ALARM CONTROL PANEL SHALL BE ADDRESSABLE, NETWORK CAPABLE AND HAVE VOICE EVACUATION CAPABILITIES. CONNECT TO CAMPUS FIRE ALARM NETWORK (REFER TO SITE WIDE FIRE ALARM SYSTEM UPGRADE SCOPE). 4. MONITOR WATERFLOW & TAMPER SWITCHES FOR SPRINKLER SYSTEM. COORDINATE WITH FIRE PROTECTION CONTRACTOR. 5. PROVIDE AN ELECTRONIC COPY OF THE SHOP DRAWINGS AND EQUIPMENT SUBMITTALS TO ARCHITECT AND FIRE PROTECTION ENGINEER FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO AUTHORITY HAVING JURISDICTION. FIRE PROTECTION NOTES: 1. SPRINKLER SYSTEM SHALL BE DESIGNED PER NFPA 13 AND ASPEN FIRE PROTECTION DISTRICT REQUIREMENTS. 2. SPRINKLERS SHOWN ON THESE PLANS ARE EXISTING TO REMAIN. IN OTHER AREAS, NEW SPRINKLER HEADS SHALL BE INSTALLED PER NFPA 13 STANDARDS. 3. SPRINKLER LOCATIONS AND PIPING ARE SCHEMATIC ONLY AND ARE INTENDED TO REPRESENT DESIGN INTENT. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SPRINKLER SYSTEM DESIGN AND INSTALLATION. 4. PROVIDE ELECTRONIC COPIES OF SHOP DRAWINGS AND EQUIPMENT SUBMITTALS TO ARCHITECT AND FIRE PROTECTION ENGINEER FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO AUTHORITY HAVING JURISDICTION. 5. PER ARCHITECTURAL PLANS, THERE ARE NO COMBUSTIBLE CONCEALED SPACES REQUIRING SPRINKLER PROTECTION. 6. PER ARCHITECTURAL PLANS, THERE ARE NO COMBUSTIBLE OVERHANGS REQUIRING EXTERIOR SPRINKLER PROTECTION. 7. COORDINATE FREEZE PROTECTION WITH GENERAL CONTRACTOR. 8. CPVC PIPING IS NOT ALLOWED. PIPING SHALL BE STEEL OR COPPER. FLAG NOTES O1 LOCATION OF EXISTING 4" FIRE SPRINKLER WATER ENTRY. PROVIDE BACKFLOW PREVENTER, WATERFLOW AND TAMPER SWITCH AND OTHER ACCESSORIES REQUIRED BY NFPA 13. O PROPOSED LOCATION OF FIRE DEPARTMENT CONNECTION. VERIFY LOCATION WITH ASPEN FIRE PROTECTION DISTRICT. O3 COORDINATE NUMBER AND LOCATION OF FLOW/TAMPER SWITCHES WITH FIRE PROTECTION CONTRACTOR. Oa PROVIDE SMOKE DETECTOR, HEAT DETECTOR AND MODULES TO ACHIEVE ELEVATOR RECALL, SHUNT TRIP, HAT LIGHT AND SHUNT TRIP MONITORING IN ELEVATOR EQUIPMENT ROOM. O5 FIRE ALARM CONTROL PANEL WITH VOICE EVACUATION. PROVIDE LCD DISPLAY AND MICROPHONE ALONG WITH ADEQUATE AMPLIFIERS TO ACCOMMODATE FUTURE TENANT BUILDOUTS. SPRINKLER AND FIRE ALARM DEV 204 ARE EXISTING. REPLACE FII INITIATING DEVICES ON A ONE -F( CONVERT HORN/STROBES TO SPI REWIRE AS NEEDED. SPRINKLER PIPING ARE EXISTING TO REMAIN. AN O F a U W 0 z O y w x a z z N 00 O 00 0) 0 00) T _ CD r, rn rn 4-! O 0 I L ® 1 L O_ (V^ c/ ! • ` 1 • CD O 00O 0 r O c o O U / O U 0 M N O Of rL � Z O F— m Q W z O w 0 _ 06 J C/) Z Q O � 11"Q O >m LL. z v) O O_ w O Lu cr- F— (-) M m Q z Lu O O 0w z 0 L U u1 N Cn Lu Q 0,, LL u l 0 SHEET DESCRIPTION: FIRE ALARM & FIRE PROTECTION UPPER LEVEL DATE: 2/27/17 L ISSUE: FOR PERMIT SHEET#: F-1.2