Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com DTW Essenza Square DownlightsProduct Overview
Type: Recessed Square Downlight, Accent, Wall Wash
Wattage: 12W (IC/AT), 15W
Lumen Output: 866 lm max (EZSD trim, 15W, Spot optic)
Color Temp: 3000K to 1800K
CRI: 95+
Dimming: TRIAC & ELV (120V/277V) - 5% Dim
Lutron A Series (120V/277V), 3-wire/EcoSystem
Hi-lume® - 1% dim
Lutron H Series (120V/277V), EcoSystem, Hi-lume® -
1% dim with soft on, fade to black
0-10V (120V/277V) - 1% Dim
DALI dimming - 1% Dim
PROJECT: TYPE:
33
Downlight
Shower
Pinhole Downlight
Lens Wall Wash
Adjustable
Essenza®
Dim-To-Warm
Square Downlights Features
Add ambiance to any hospitality, residential, retail or commercial space. Amerlux
Essenza Downlight Dim-To-Warm option offers a lower kelvin temperature as you
dim the lights. An adaptable light source in a cost- effective, solid state lighting
package. The Dim-To-Warm option can tap into the powerful mediums of light
and color to enhance the experience, well-being, and human emotion. Amerlux
Dim-To-Warm allows designers to simulate the familiar glow and dimming of
incandescent lamps.
Fixture Type
New Construction Remodeler Trim Trimless
Yes Yes Yes Yes
Dim-To-Warm CCT Curve
1800
2000
2200
2400
2600
2800
3000
3200
0 5025 75 100CCT (K)Dimming (% of Light Output)
Electronic constant current LED driver
*Includes 2W thermal protector
Electrical Data
12W (IC/AT) 15W*
System
Watts Amps
System
Watts Amps
120V 12 0.10 15 0.13
277V 12 0.04 16 0.06
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 2 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Model
For New Construction
EZ-NC-DTW-A17† (New Construction)
EZ-CP-DTW-A17† (Chicago Plenum (CCEA) housing)
EZ-IC-DTW-A17† (Insulated Ceiling/air tight housing, 12W
only)
For Existing Ceilings
EZ-REM-DTW-A17†
Style
T - trimmed
STL - square trimless
Wattage
12 (IC/AT)
15 (not available for use with IC housing)
Voltage
120
277
120/277 (for use with IC housing only)
Driver (for non-dimming, select LE/TE option)
LE/TE - TRIAC/ELV dimming
HILUME-A - Lutron Hi-lume® A Series, 3-wire/EcoSystem,
Hi-lume®, 1% dim
HILUME-H - Lutron Hi-lume® H Series, EcoSystem
Hi-lume®, 1% dim with soft on, fade to black
0-10V - 0-10V dimming; 1% dim
DALI - DALI dimming, 1% dim
Options/Accessories
EM - integral emergency battery pack with remote test
switch, requires 7" ceiling clearance (not available for use
with REM, CP or IC option)
Model
EZSD-DTW-A17† (downlight)
EZSA-DTW-A17† (adjustable)
EZSLW-DTW-A17† (wall wash)
EZSSHW-DTW-A17† (shower, not available for use in
trimless)
EZSPD-DTW-A17† (pinhole downlight)
Style
T - trimmed
TL - trimless (not available for Shower (EZSSHW) trim)
Finish
SD/SA/SLW/SSHW Trims:
Trimmed Trimless
MWW - matte white, white fl ange MW - matte white
SPD Trim (Trimmed & Trimless):
MW - matte white
Beam Spreads (not for use with EZSLW trim)
VNF - very narrow fl ood, 18°
FL - fl ood, 35°
WF - wide fl ood, 45°
VWF - very wide fl ood, 50°
Color Temp
95+ CRI
309 - 3000K-95+
† The "A" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not
changing the overall fi xture aesthetic and are refl ected in the published performance data. Please contact your Amerlux representative for
explanations of changes.
1
1
2
2
3
3
4
4
5
5
5
6
61
1
2
2
3
3
4
4
5
Housing/Frame Ordering Information
Trim Ordering Information
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 3 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Specifi cations
Application
Hospitality, retail and commercial ambient, accent and wall
wash lighting
Construction
20 ga. galvanized steel frame
18 ga. galvanized steel splice housing and hanger brackets
(not for use with Remodeler version)
Cast aluminum plaster frame with perforated face (for
trimless version only)
Die-cast optical housing, trim and heatsink
Optical
Beam spreads (for SD, SA, SSHW & SPD fi xtures):
Very Narrow Flood, 18º; Flood, 35º; Wide Flood, 45º;
Very Wide Flood, 50º
Tilt (for SA fi xture): 0-30°
Lens:
SLW fi xture: Engineered nano technology lens provides
high transmission while concealing LED image
Shower fi xture: Siliconed solite lens
LED
Color Temp Options:
3000K dims to 1800K (12W fi xtures start at 2900K)
CRI: 95+
R9 Values: 85 (95 CRI)
Binning: 3 MacAdam (SDCM)
Life: 50,000+ hrs, > 70% of initial lumens at 50,000 hrs
Electrical
Wattage: 12 (IC/AT), 15
Electronic constant current LED driver, 120V/277V input
This product complies with IEEE C62.41 for surge endurance up to
2.5KV. Amerlux® recommends using additional surge protection
with this unit (supplied by others), surge and over voltage
damage is not covered under warranty.
Note: Drivers are universal input voltage but thermal
protector is voltage specifi c
Drivers
LE/TE - Leading Edge, TRIAC, forward phase/Trailing Edge,
ELV, reverse phase
0-10V and Lutron systems also available
See pages 6-9 for more dimming information
Finish
Powder coat paint
Consult factory for custom fi nishes
Mounting
Trimmed
For use in T-grid or sheetrock ceilings, max thickness 1"
Trimless
For use in sheetrock ceilings, max thickness 5/8"
Certifi cations
CSA listed to UL standards
Damp location
IC/AT (insulated ceiling/air tight) rated, 12W only, optional
Chicago Plenum (CCEA) optional
Warranty
3 year limited warranty
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 4 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Essenza Square Downlight:
Ceiling cut out: 4” dia.
14 1/2” min - 26” max
Optional IC/AT housing (12w only)4”11 1/2”12 3/16”1 7/16”6 1/8”7 3/4”9”4”
2 1/4”8 13/16”
Lens Wall Wash
Downlight
Pinhole Downlight
Adjustable
Shower
2 15/16”
up to 1”
up to 1”
up to 1”
4 3/8”
4 3/8”
4 3/8”
2 5/16”
2 5/16”2 5/16”
2 5/16”3 1/8”3 1/8”3/8”
3/8”
up to 1”
30°3 1/8”3/8”
up to 1”3 1/8”3/8”
1 13/16”
2 15/16”
2 15/16”
2 15/16”
2 15/16”3 1/8”
4 3/8”
4 3/8”
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 5 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Essenza Square Downlight Trimless:
Optional IC/AT housing (12w only)4”14 1/2” min - 26” max
11 1/2”
7 1/2”3 7/8”12 3/16”7 3/4”Trimless Ceiling cut out: 4 1/2” sq.
Plaster Frame Installation Detail (for trimless fi xture only)
1. Refl ector Trim
2. Aperture plate
3. Ceiling ⅝”
4. Cast Aluminum Plaster Frame
5. Plaster Skim Coat (by others)
6. 6-32 Type F Thread Cutting Screw 1
23
4 5
6
Lens Wall Wash
Downlight
Pinhole Downlight
Adjustable
3 5/8”
3 5/8”
3 5/8”
3 5/8”
5/8”
5/8”5/8”
5/8”
2 15/16”
2 15/16”
2 15/16”
1 13/16”
3 1/8”3 1/8”3 1/8”
3 1/8”
30°
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 6 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Essenza Square Remodeler:
STRUCTURE
Lens Wall Wash
Pinhole Downlight
Downlight Adjustable
Shower
2 9/16”2 9/16”
4 3/8”
2 5/16”
3 1/16”3 1/2”
30°
3 5/16”
7 9/16”
3 5/16”
A
2 1/4”
5/8” (1" max)5 1/2” minClearance2 1/4”
Ø6 1/4”
4”
To allow driver removal
through cut out.
2 9/16”
2 9/16”
3 5/16”
3 1/16”
3 1/16”
9 1/2”
9 1/2”
9 1/2”
9 1/2”
9 1/2”
2 9/16”
8 1/16”
Product A
EZ-SD-REM 2
3/8”
EZ-SA-REM 3
3/16”
EZ-SLW-REM 3
5/16”
EZ-SSHW-REM 2
3/8”
EZ-SPD-REM 2
3/8”
3 1/16”
4 3/8”
2 5/16”
4 3/8”
2 5/16”
4 3/8”
2 5/16”
4 3/8”
1 13/16”
Ceiling cut out: 4” dia.
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 7 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Essenza Square Remodeler Trimless:
STRUCTURE
3 5/16”
7 9/16”
3 5/16”
A
2 1/4”
5/8” 5 1/2” minClearance8 1/16”2 1/4”
4”
To allow driver removal
through cut out.
Lens Wall Wash Pinhole Downlight
Downlight Adjustable
2 9/16”2 9/16”
3 5/8”
2 5/16”
3 1/16”3 7/16”
30°
2 9/16”
2 9/16”1 13/16”
3 1/4”
3 1/16”
11 1/16”11 1/16”
11 1/16”
11 1/16”
Plaster Frame Installation Detail (for trimless fi xture only)
1. Refl ector Trim
2. Aperture plate
3. Ceiling ⅝”
4. Cast Aluminum Plaster Frame
5. Plaster Skim Coat (by others)
6. 6-32 Type F Thread Cutting Screw
1
2
3
45
6
3 1/16”
Product A
EZ-SD-REM-TL 2
5/16”
EZ-SA-REM-TL 3
3/16”
EZ-SLW-REM-TL 3
1/4”
EZ-SPD-REM-TL 2
5/16”
3 5/8”
3 5/8”
2 5/16”
3 5/8”
2 5/16”
Trimless Ceiling cut out: 4 1/2” sq.
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 8 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Essenza Square Downlight:
FIXTURE DATA: (Complete photometric data (.ies format) available upon request)
Very Wide Flood (VWF)
Distribution, 50º
LTL # 11919582.04
Lumens: 663
Wide Flood (WF)
Distribution, 45º
LTL # 11919582.03
Lumens: 790
15W LED, 3000K-95+
Application Data:
D
W
L L
WFCCB
W
FC
CB
L
30°
D
30º
FC
Flood (FL)
Distribution, 35º
LTL# 11919582.02
Lumens: 796
Very Narrow Flood (VNF)
Distribution, 18º
LTL # 11919582.01
Lumens: 866
0o Aiming Angle
Horizontal
Footcandles
FloodWide FloodVery Wide FloodVery NarrowFlood D FC L W
5.0’ 141 1.6 1.6
7.5’ 64 2.5 2.5
10.0’ 36 3.3 3.3
12.5’ 23 3.9 3.9
D FC L W
5.0’ 57 3.1 3.1
7.5’ 26 4.5 4.5
10.0’ 15 5.9 5.9
12.5’ 9 7.5 7.5
D FC L W
5.0’ 42 3.6 3.6
7.5’ 19 5.4 5.4
10.0’ 11 7.2 7.2
12.5’ 7 9.0 9.0
D FC L W
5.0’ 25 3.8 3.8
7.5’ 11 5.7 5.7
10.0’ 7 7.7 7.7
12.5’ 4 9.7 9.7
Notes and Defi nitions:
Beam spread is to 50% center beam candlepower (CBCP).
D=Distance to floor or wall.
FC=Footcandles on floor or wall at center beam aiming location.
L=Eff ective Visual Beam length in feet (50% of maximum footcandle level).
W=Eff ective Visual Beam width in feet (50% of maximum footcandle level).
CB=Distance across or down to center beam location.
Candelas at Nadir
Deg Candela
0 3674
5 2877
15 1011
25 392
35 143
45 40
Candelas at Nadir
Deg Candela
0 1474
5 1392
15 900
25 434
35 192
45 72
Candelas at Nadir
Deg Candela
0 1086
5 1051
15 799
25 459
35 223
45 92
Candelas at Nadir
Deg Candela
0 648
5 629
15 497
25 317
35 189
45 118
0 15 30
45
60
75
90
1000
2000
3000
0 15 30
45
60
75
90
250
500
750
1000
1250
1500
0 15 30
45
60
75
90
250
500
750
1000
0 15 30
45
60
75
90
150
300
450
600
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 9 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Essenza Square Adjustable:
FIXTURE DATA: (Complete photometric data (.ies format) available upon request)
Wide Flood (WF)
Distribution, 45º
LTL # 11919582.07
Lumens: 679
15W LED, 3000K-95+
Application Data:
D
W
L L
WFCCB
W
FC
CB
L
30°
D
30º
FC
Flood (FL)
Distribution, 35º
LTL# 11919582.06
Lumens: 699
Very Narrow Flood (VNF)
Distribution, 18º
LTL # 11919582.05
Lumens: 780
0o Aiming Angle
Horizontal
Footcandles
FloodWide FloodVery NarrowFlood D FC L W
5.0’ 145 1.6 1.6
7.5’ 66 2.5 2.5
10.0’ 37 3.3 3.3
12.5’ 24 3.9 3.9
D FC L W
5.0’ 58 3.1 3.1
7.5’ 26 4.5 4.5
10.0’ 15 5.9 5.9
12.5’ 10 7.4 7.4
D FC L W
5.0’ 43 3.6 3.6
7.5’ 19 5.4 5.4
10.0’ 11 7.1 7.1
12.5’ 7 8.9 8.9
Notes and Defi nitions:
Beam spread is to 50% center beam candlepower (CBCP).
D=Distance to floor or wall.
FC=Footcandles on floor or wall at center beam aiming location.
L=Eff ective Visual Beam length in feet (50% of maximum footcandle level).
W=Eff ective Visual Beam width in feet (50% of maximum footcandle level).
CB=Distance across or down to center beam location.
Candelas at Nadir
Deg Candela
0 3781
5 2933
15 1042
25 335
35 61
45 33
Candelas at Nadir
Deg Candela
0 1515
5 1430
15 919
25 405
35 91
45 41
Candelas at Nadir
Deg Candela
0 1103
5 1067
15 809
25 445
35 117
45 46
0 15 30
45
60
75
90
1000
2000
3000
4000
0 15 30
45
60
75
90
500
1000
1500
0 15 30
45
60
75
90
250
500
750
1000
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 10 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Essenza Square Lens Wall Wash:
FIXTURE DATA: (Complete photometric data (.ies format) available upon request)
Application Data:
Footcandles on Wall
Lens Wall Wash (RLW) Distribution
LTL #11919582.11
Lumens: 533
ZONAL LUMEN SUMMARYZONAL LUMEN SUMMARY
Zone Lumens %Fixt
0-40 270 50.7
0-60 449 84.1
0-90 533 100.0
90-180 0 0.0
Luminaire Effi cacy: 36.3 lumens/wattLuminaire Effi cacy: 36.3 lumens/watt
Footcandles are average and rounded off .
Data for multiple units are based
on a minimum of fi ve units.
1.5 Feet From Wall
0.5’ 29 30 32 30 29
1.5’ 45 47 49 47 45
2.5’ 28 31 32 31 29
3.5’ 17 19 19 19 17
4.5’ 11 12 12 12 11
5.5’ 7 8 8 8 8
6.5’ 5 6 6 6 6
7.5’ 4 5 5 5 4
1.5’Distance from ceiling1.5 Feet From Wall
0.5’ 20 27 21 27 21 27 20
1.5’ 34 38 36 38 36 38 34
2.5’ 23 24 25 25 25 24 23
3.5’ 14 15 16 16 16 15 14
4.5’ 9 10 10 10 10 10 9
5.5’ 6 7 7 7 7 7 6
6.5’ 5 5 5 5 5 5 5
7.5’ 4 4 4 4 4 4 4
2’Distance from ceiling2 Feet From Wall
Distance from ceiling1.5’2’
0.5’ 12 13 13 13 13 13 12
1.5’ 24 26 26 26 26 26 24
2.5’ 22 23 24 24 24 23 22
3.5’ 15 17 17 18 17 17 15
4.5’ 11 12 12 12 12 12 11
5.5’ 8 8 9 9 9 8 8
6.5’ 6 6 6 7 6 6 6
7.5’ 5 5 5 5 5 5 5
2’2’
15W LED, 3000K-95+
0 15 30
45
60
75
90
50
100
150
200
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 11 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Essenza Square Shower:
FIXTURE DATA: (Complete photometric data (.ies format) available upon request)
Wide Flood (WF)
Distribution, 45º
LTL # 11919582.10
Lumens: 742
15W LED, 3000K-95+
Application Data:
D
W
L L
WFCCB
W
FC
CB
L
30°
D
30º
FC
Flood (FL)
Distribution, 35º
LTL# 11919582.09
Lumens: 748
Very Narrow Flood (VNF)
Distribution, 18º
LTL # 11919582.08
Lumens: 813
0o Aiming Angle
Horizontal
Footcandles
FloodWide FloodVery NarrowFlood D FC L W
5.0’ 93 2.2 2.2
7.5’ 42 3.3 3.3
10.0’ 24 4.2 4.2
12.5’ 15 5.3 5.3
D FC L W
5.0’ 48 3.2 3.2
7.5’ 22 4.7 4.7
10.0’ 12 6.2 6.2
12.5’ 8 7.8 7.8
D FC L W
5.0’ 38 3.6 3.6
7.5’ 17 5.4 5.4
10.0’ 10 7.2 7.2
12.5’ 6 9.1 9.1
Notes and Defi nitions:
Beam spread is to 50% center beam candlepower (CBCP).
D=Distance to floor or wall.
FC=Footcandles on floor or wall at center beam aiming location.
L=Eff ective Visual Beam length in feet (50% of maximum footcandle level).
W=Eff ective Visual Beam width in feet (50% of maximum footcandle level).
CB=Distance across or down to center beam location.
Candelas at Nadir
Deg Candela
0 2413
5 2103
15 961
25 389
35 155
45 56
Candelas at Nadir
Deg Candela
0 1246
5 1181
15 796
25 412
35 194
45 79
Candelas at Nadir
Deg Candela
0 974
5 940
15 713
25 427
35 219
45 94
0 15 30
45
60
75
90
500
1000
1500
2000
2500
0 15 30
45
60
75
90
250
500
750
1000
1250
0 15 30
45
60
75
90
250
500
750
1000
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 12 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
DIMMING COMPATIBILITY:
Amerlux® Essenza fi xtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general
compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming confi guration as the exact full confi guration
(Dimmer, Fixture Quantity, Voltage, etc) may aff ect dimming performance.
TRIAC (Forward Phase) DIMMING (Standard)
Utilizes “Standard” incandescent dimmers that are in wide use in installations across the US. Best for retrofi t applications where TRIAC
dimmers are installed.
Notes:
• 120V or 277V*
• Dims down to less than 5% light output (most cases)
• Consult Dimming manufacturer for installation
instructions - DO NOT SHARE NEUTRALS!
• Must meet dimmer Minimum Load Requirements per
dimming manufacturer
Lutron “Diva”
Lutron “Nova-T”
Lutron “Maestro”
Lutron “Vareo”
Lutron “Skylark”
Lutron “GP” Panel
Lutron Grafi k Eye QS
Compatible Dimmers
Wall Box (Incandescent Style, Wattage as required)Central System
TRIAC Wiring Diagram
ELV - Electronic Low Voltage (Reverse Phase) DIMMING (Standard)
Utilizes specialized “ELV” dimmers. Best for New Construction applications
Notes:
• 120V or 277V*
• Dims down to less than 5% light output (most cases)
• Consult Dimming manufacturer for installation
instructions - DO NOT SHARE NEUTRALS!
• Must meet dimmer Minimum Load Requirements
Lutron “Diva”
Lutron “Nova-T”
Lutron “Maestro”
Leviton “Surslide”
Lutron “Vareo”
Lutron “Skylark”
Leviton “Vizio”
Lutron “GP” Panel with PHPM-PA
Interface
Lutron Grafi k Eye QS with
PHPM-PA Interface
Compatible Dimmers
Wall Box (ELV Style)Central System
0-10V - DIMMING (-0-10V Option)
Integrates into a variety of building management and daylighting controls
Notes:
• 120V or 277V*
• Dims down to 1% light output
• Requires interface to turn off power to driver
• Consult Dimming manufacturer for installation
instructions - DO NOT SHARE NEUTRALS!
Lutron “Diva” - DVTV with PP-
120H Interface
Leviton Renoir II 0-10v Lutron Grafi k Eye with
GRX-TVI Interface
Compatible Dimmers
Wall Box Central System
Black
White
Green
Red
Black
V+
V-
Driver
Line
Neutral
TRIAC
Dimming
Control Neutral
ELV Wiring Diagram
Black
White
Green
Red
Black
V+
V-
Driver
Line
Neutral
ELV
Dimming
Control Neutral
0-10V Wiring Diagram
Gray
Purple
Black
White
Green
Driver
Line
Neutral
0-10V
Dimming
Control
Neutral
Red
Black
V+
V-
0-10V (-)
0-10V (+)
Ground
Ground
Ground
Ground
Ground
Ground
Switched Hot
Line
Line
Notes:
* Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method.
Please refer to 277V dimming installation instructions for 277V wiring diagrams.
--- NOTE: INFORMATION BELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FACTORY ---
Passion. Power. Performance.
PROJECT: TYPE: DTW Essenza Square DownlightsEssenza®
Dim-To-Warm Square Downlights
LIT-2145 • 03/15/18 • Page 13 of 13
Amerlux reserves the right to change details that do not aff ect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com
Notes:
* Driver is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method.
Please refer to 277V dimming installation instructions for 277V wiring diagrams.
LUTRON A-SERIES HI-LUME / ECOSYSTEM (-DIM-HILUME Option)
Integrates into Lutron EcoSystem building management
Notes:
• 120V or 277V*
• Dims down to less than 5% light output
• May use 3-Wire or EcoSystem Control
• Consult Dimming manufacturer for installation
instructions - DO NOT SHARE NEUTRALS!
3-Wire Wiring Diagram
EcoSystem Digital Control Wiring Diagram
Compatible Dimmers
Wall Box (3-Wire Fluorescent)
DIVA
Maestro
Nova T
Vareo
Central System
Lutron EcoSystem compatible controls
DIMMING COMPATIBILITY:
Amerlux® Essenza fi xtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general
compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming confi guration as the exact full confi guration
(Dimmer, Fixture Quantity, Voltage, etc) may aff ect dimming performance.
Purple Stripe
Purple
Black
White
Green
Red
Black
V+
V-
Driver
Line
Neutral
ECOSYS Bus
EcoSystem
Dimming
Control
Orange
E2
E1
Dimmed Hot
E1
E2
Ground
Purple Stripe
Purple
Black
White
Green
Red
Black
V+
V-
Driver
Line
Neutral
Cap unused
ECOSYS wires
3-Wire
Phase
Dimming
Control
Orange Dimmed Hot
Ground Neutral
Neutral
Ground
E1
E2
(Cap off Orange wire)
Switched Hot
Switched Hot
--- NOTE: INFORMATION BELOW IS FOR WIRED DIMMERS ONLY. FOR WIRELESS DIMMERS, CONSULT FACTORY ---