Loading...
HomeMy WebLinkAboutFile Documents.525 E Cooper Ave.0119.2018 (6).ACBKTEST REPORT Report No.: C0175.01-801-47 Rendered to: SKYLINE SKY-LITES, LLC Colorado Springs, Colorado PRODUCT TYPE: Unit Skylight Plastic Glazed SERIES/MODEL: TPCMD 9898; TPCMD 7696; TPCMD 2852; TDCMD 7676; TDCMD 5296 SPECIFICATION: AAMA/WDMA/CSA 101/I.S.2/A440-11, NAFS - North American Fenestration Standard/Specification for Windows, Doors, and Skylights Test Dates: 06/25/12 Through: 06/29/12 Report Date: 07/11/12 Revision 1: 08/22/12 Architectural Testing Summary of Results Summary of Results Title Test Specimen #1 Test Specimen #2 Primary Product Designator PG40 2477 x 2477 (98 x 98)-SKP PG40 1892 x 2400 (75 x 95)-SKP Design Pressure ±1920 Pa (±40.10 psf) ±1920 Pa (±40.10 psf) Air Infiltration <0.1 L/s/m2 (<0.01 cfm/ft2) <0.1 L/s/m2(<0.01 cfm/ft2) Water Penetration Resistance Test Pressure 580 Pa (12.11 psf) 580 Pa (12.11 psf) Summary of Results Title Test Specimen #3 Test Specimen #4 Primary Product Designator PG100 692 x 1302 (27 x 51)-SKP PG40 892 x 892 (75 x 75)- SKP Design Pressure ±4800 Pa (±100.25 psf) ±1920 Pa (±40.10 psf) Air Infiltration <0.1 L/s/m2 (<0.01 cfm/ft2) <0.1 L/s/m2(<0.01 cfm/ft2) Water Penetration Resistance Test Pressure 580 Pa (12.11 psf) 580 Pa (12.11 psf) Summary of Results Title Test Specimen #5 Primary Product Designator PG40 1302 x 2400 (51 x 95)-SKP Design Pressure ±1920 Pa (±40.10 psf) Air Infiltration <0.1 L/s/m2 (<0.01 cfm/ft2) Water Penetration Resistance Test Pressure 580 Pa (12.11 psf) Test Completion Date: 06/29/2012 Reference must be made to Report No. C0175.01-801-47, dated 07/11/12 for complete test specimen description and detailed test results. Architectural Testing Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 1 of 15 1.0 Report Issued To: Skyline Sky-Lites, LLC 2925 Delta Drive Colorado Springs, Colorado 80910 2.0 Test Laboratory: Architectural Testing, Inc. 2865 Market Loop Southlake, TX 76092 817-410-7202 3.0 Project Summary: 3.1 Product Type: Unit Skylight Plastic Glazed 3.2 Series/Model: TPCMD 9898; TPCMD 7696; TPCMD 2852; TDCMD 7676; TDCMD 5296 3.3 Compliance Statement: Results obtained are tested values and were secured by using the designated test method(s). Test Specimen #1: PG40 2477 x 2477 (98 x 98)-SKP; Test Specimen #2: PG40 1892 x 2400 (75 x 95)-SKP; Test Specimen #3: PG100 692 x 1302 (27 x 51)-SKP; Test Specimen #4: PG40 892 x 892 (75 x 75)-SKP; Test Specimen #5: PG40 1302 x 2400 (51 x 95)-SKP. 3.4 Test Dates: 06/25/2012 -06/29/2012 3.5 Test Record Retention End Date: All test records for this report will be retained until 07/11/2016. 3.6 Test Location: Skyline Sky-Lites, LLC test facility in Colorado Springs, Colorado. Calibration of test equipment was performed by Architectural Testing in accordance with AAMA 205-01 "In-Plant Testing Guidelines for Manufacturers and Independent Laboratories". 3.7 Test Sample Source: The test specimen was provided by the client. Representative samples of the test specimen(s) will be retained by Architectural Testing for a minimum of four years from the test completion date. 3.8 Drawing Reference: The test specimen drawings have been reviewed by Architectural Testing and are representative of the test specimen(s) reported herein. Test specimen construction was verified by Architectural Testing per the drawings located in Appendix B. Any deviations are documented herein or on the drawings. 3.9 List of Official Observers: Name Company Dave Norgren Skyline Sky-Lites, LLC Andy Cost Architectural Testing, Inc. www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 2 of 15 4.0 Test Specification(s): AAMA/WDMA/CSA 101/I.S.2/A440-11, NAFS - North American Fenestration Standard/Specification for Windows, Doors, and Skylights 5.0 Test Specimen Description: 5.1 Product Sizes: Test Specimen #1: PG40 2477 x 2477 (98 x 98)-SKP Overall Area: 3.1 m² (33.5 ft2) Width Height millimeters inches millimeters Inches Overall size 2477 97-1/2 2477 97-1/2 Retaining angle 2477 97-1/2 2477 97-1/2 Frame outer dimension 2464 97 2464 97 Curb outer dimension 2432 95-3/4 2432 95-3/4 Curb DLO 2356 92-3/4 2356 92-3/4 Test Specimen #2: PG40 1892 x 2400 (75 x 95)-SKP Overall Area: 4.5 m² (48.9 ft2) Width Height millimeters inches millimeters Inches Overall size 1892 74-1/2 2400 94-1/2 Retaining angle 1892 74-1/2 2400 94-1/2 Frame outer dimension 1880 74 2388 94 Curb outer dimension 1848 72-3/4 2356 92-3/4 Curb DLO 1772 69-3/4 2280 89-3/4 www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 3 of 15 5.0 Test Specimen Description: (Continued) Test Specimen #3: PG100 692 x 1302 (27 x 51)-SKP Overall Area: 3.1 m² (33.5 ft2) Width Height millimeters inches millimeters Inches Overall size 692 27-1/4 1302 51.-1/4 Retaining angle 692 27-1/4 1302 51-1/4 Frame outer dimension 679 26-3/4 1289 50-3/4 Curb outer dimension 648 25-1/2 1257 49-1/2 Curb DLO 572 22-1/2 1181 46-1/2 Test Specimen #4: PG40 892 x 892 (75 x 75)-SKP Overall Area: 3.6 m² (38.5 ft2) Width Height millimeters inches millimeters Inches Overall size 1892 74-1/2 1892 74-1/2 Retaining angle 1892 74-1/2 1892 74-1/2 Frame outer dimension 1880 74 1880 74 Curb outer dimension 1848 72-3/4 1848 72-3/4 Curb DLO 1772 69-3/4 1772 69-3/4 Test Specimen #5: PG40 1302 x 2400 (51 x 95)-SKP Overall Area: 3.1 m² (33.6 ft2) Width Height millimeters inches millimeters Inches Overall size 1302 51-1/4 2400 94-1/2 Retaining angle 1302 51-1/4 2400 94-1/2 Frame outer dimension 1289 50-3/4 2388 94 Curb outer dimension 1257 49-1/2 2350 92-1/2 Curb DLO 1181 46-1/2 2273 89-1/2 www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 4 of 15 5.0 Test Specimen Description: (Continued) The following descriptions apply to all specimens. 5.2 Frame Construction: Frame Member Material Description Frame Aluminum Thermally Broken Retaining angle Aluminum Aluminum Angle Joinery Type Detail Frame corners Welded Corners were mitered and welded along the lateral face and on the top face. The joint was covered with silicone. Retaining angle Specimens 1,2,4, and 5 Welded The retaining angle was mitered and welded at each corner. Retaining angle Specimen 3 Welded The retaining angle was notched and bent at three corners with one corner welded Retaining angle to Frame Specimens 1, 2, 4, and 5 #8 x 1/2" self- tapping pan head screws One screw located 3" from each corner and 12" on center thereafter. Retaining angle to Frame Specimen 3 #8 x 1/2" self- tapping pan head screws One screw located 5" from each corner and 1 at the midpoint of each side. 5.3 Sash Construction: None 5.4 Weatherstripping: No weatherstripping was utilized. www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 5 of 15 5.0 Test Specimen Description: (Continued) 5.5 Glazing: No conclusions of any kind regarding the adequacy or inadequacy of the glass in any glazed test specimen(s) can be made. Test Specimen #1: PG40 2477 x 2477 (98 x 98)-SKP Glazing Type Glazing Glazing Method Outer Pyramid 0.245" Thick Acrylic Pyramid Exterior glazed. Secured to the inner dome with silicone at the interior and with a retaining angle at the exterior. Inner Pyramid 0.110” Thick Acrylic Pyramid Exterior glazed with a vinyl gasket at the interior and secured to the outer dome with silicone at the exterior. Location Quantity Daylight Opening Glass Bite millimeters inches Frame DLO 1 2356 x 2356 92-3/4 x 92-3/4 1-1/2" Test Specimen #2 PG40 1892 x 2400 (75 x 95)-SKP Glazing Type Glazing Glazing Method Outer Pyramid 0.177" Thick Acrylic Pyramid Exterior glazed. Secured to the inner dome with silicone at the interior and with a retaining angle at the exterior Inner Pyramid 0.111" Thick Acrylic Pyramid Exterior glazed with a vinyl gasket at the interior and secured to the outer dome with silicone at the exterior. Location Quantity Daylight Opening Glass Bite millimeters inches Frame DLO 1 1772 x 2280 69-3/4 x 89-3/4 1-1/2" www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 6 of 15 5.0 Test Specimen Description: (Continued) Test Specimen #3: PG100 692 x 1302 (27 x 51)-SKP Glazing Type Glazing Glazing Method Outer Pyramid 0.111" Thick Acrylic Pyramid Exterior glazed. Secured to the inner dome with silicone at the interior and with a retaining angle at the exterior. Inner Pyramid 0.111" Thick Acrylic Pyramid Exterior glazed with a vinyl gasket at the interior and secured to the outer dome with silicone at the exterior. Location Quantity Daylight Opening Glass Bite millimeters inches Frame DLO 1 572 x 1181 22-1/2 x 46-1/2 1-1/2" Test Specimen #4: PG40 892 x 892 (75 x 75)-SKP Glazing Type Glazing Glazing Method Outer Dome 0.152" Thick Acrylic Dome Exterior glazed. Secured to the inner dome with silicone at the interior and with a retaining angle at the exterior. Inner Dome 0.104" Thick Acrylic Dome Exterior glazed with a vinyl gasket at the interior and secured to the outer dome with silicone at the exterior. Location Quantity Daylight Opening Glass Bite millimeters inches Frame DLO 1 1772 x 1772 69-3/4 x 69-3/4 1-1/2" www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 7 of 15 5.0 Test Specimen Description: (Continued) Test Specimen #5: PG40 1302 x 2400 (51 x 95)-SKP Glazing Type Glazing Glazing Method Outer Dome 0.159" Thick Acrylic Dome Exterior glazed. Secured to the inner dome with silicone at the interior and with a retaining angle at the exterior with 1- 1/2" glazing bite. Inner Dome 0.110" Thick Acrylic Dome Exterior glazed with a vinyl gasket at the interior and secured to the outer dome with silicone at the exterior. Location Quantity Daylight Opening Glass Bite millimeters inches Frame DLO 1 1181 x 2273 46-1/2 x 89-1/2 1-1/2" 5.2 Drainage: No drainage was utilized. 5.3 Hardware: No hardware was utilized. 5.4 Reinforcement: No reinforcement was utilized. 5.5 Screen Construction: No screen was utilized. 6.0 Installation: The specimen was installed onto a 2x6 Spruce-Pine-Fir wood curb. The frame overlap of the curb allowed for a 1/4" shim space full perimeter. The exterior perimeter of the skylight was sealed with single sided foam tape between the frame and the curb. Location Anchor Description Anchor Location Frame leg Specimens 1, 2, 4, and 5 #10 x 1-1/2" wood screw 3" from each corner and 12" on center thereafter. Frame leg Specimen 3 #10 x 1-1/2" wood screw One screw located 5" from each corner and 1 at the midpoint of each side. www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 8 of 15 7.0 Test Results: The temperature during testing was 27°C (80°F). The results are tabulated as follows: Test Specimen #1: PG40 2477 x 2477 (98 x 98)-SKP Title of Test Results Allowed Note Air Leakage, Infiltration per ASTM E 283 at 75 Pa (1.57 psf) <0.1 L/s/m2 (<0.01 cfm/ft2) 1.5 L/s/m2 (0.3 cfm/ft2) max. 1 Water Penetration, per ASTM E 547 N/A N/A 3 Uniform Load Deflection, per ASTM E 330 taken at retaining angle between fasteners +1440 Pa (+30.08 psf) -1440 Pa (- 30.08 psf) <0.3 mm (<0.01") <0.3 mm (<0.01") Report Only Report Only 4, 6, 7 4, 5, 7 Uniform Load Structural, per ASTM E 330 taken at retaining angle between fasteners +2880 Pa (+60.15 psf) -2160 Pa (-45.11 psf) <0.3 mm (<0.01") <0.3 mm (<0.01") 1.3 mm (0.05") max. 1.3 mm (0.05") max. 6, 7 5, 7 Optional Performance Water Penetration, per ASTM E 547 at 580 Pa (12.11 psf) Pass No leakage 2 Uniform Load Deflection, per ASTM E 330 taken at retaining angle between fasteners +1920 Pa (+40.10 psf) -1920 Pa (- 40.10 psf) <0.3 mm (<0.01") <0.3 mm (<0.01") Report Only Report Only 4, 6, 7 4, 5, 7 Uniform Load Structural, per ASTM E 330 taken at retaining angle between fasteners +3840 Pa (+80.20 psf) -2880 Pa (-60.15 psf) <0.3 mm (<0.01") <0.3 mm (<0.01") 1.3 mm (0.05") max. 1.3 mm (0.05") max. 6, 7 5, 7 www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 9 of 15 7.0 Test Results: (Continued) Test Specimen #2: PG40 1892 x 2400 (75 x 95)-SKP Title of Test Results Allowed Note Air Leakage, Infiltration per ASTM E 283 at 75 Pa (1.57 psf) <0.1 L/s/m2 (<0.01 cfm/ft2) 1.5 L/s/m2 (0.3 cfm/ft2) max. 1 Water Penetration, per ASTM E 547 N/A N/A 3 Uniform Load Deflection, per ASTM E 330 taken at retaining angle between fasteners +1440 Pa (+30.08 psf) -1440 Pa (- 30.08 psf) N/A N/A 3 Uniform Load Structural, per ASTM E 330 taken at retaining angle between fasteners +2880 Pa (+60.15 psf) -2160 Pa (-45.11 psf) N/A N/A 3 Optional Performance Water Penetration, per ASTM E 547 at 580 Pa (12.11 psf) Pass No leakage 2 Uniform Load Deflection, per ASTM E 330 taken at retaining angle between fasteners +1920 Pa (+40.10 psf) -1920 Pa (- 40.10 psf) 1 mm (0.04") <0.3 mm (<0.01") Report Only Report Only 4, 6, 7 4, 5, 7 Uniform Load Structural, per ASTM E 330 taken at retaining angle between fasteners +3840 Pa (+80.20 psf) -2880 Pa (-60.15 psf) 0.3 mm (0.01") 0.3 mm (0.01") 1.3 mm (0.05") max. 1.3 mm (0.05") max. 6, 7 5, 7 www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 10 of 15 7.0 Test Results: (Continued) Test Specimen #3: PG100 692 x 1302 (27 x 51)-SKP Title of Test Results Allowed Note Air Leakage, Infiltration per ASTM E 283 at 75 Pa (1.57 psf) <0.1 L/s/m2 (<0.01 cfm/ft2) 1.5 L/s/m2 (0.3 cfm/ft2) max. 1 Water Penetration, per ASTM E 547 N/A N/A 3 Uniform Load Deflection, per ASTM E 330 taken at retaining angle between fasteners +1440 Pa (+30.08 psf) -1440 Pa (- 30.08 psf) N/A N/A 3 Uniform Load Structural, per ASTM E 330 taken at retaining angle between fasteners +2880 Pa (+60.15 psf) -2160 Pa (-45.11 psf) N/A N/A 3 Optional Performance Water Penetration, per ASTM E 547 at 580 Pa (12.11 psf) Pass No leakage 2 Uniform Load Deflection, per ASTM E 330 taken at retaining angle between fasteners +4800 Pa (+100.25 psf) -4800 Pa (- 100.25 psf) <0.3 mm (<0.01") <0.3 mm (<0.01") Report Only Report Only 4, 6, 7 4, 5, 7 Uniform Load Structural, per ASTM E 330 taken at retaining angle between fasteners +9600 Pa (+200.50 psf) -7200 Pa (-150.38 psf) <0.3 mm (<0.01") <0.3 mm (<0.01") 2 mm (0.08") max. 2 mm (0.08") max. 6, 7 5, 7 www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 11 of 15 7.0 Test Results: (Continued) Test Specimen #4: PG40 892 x 892 (75 x 75)-SKP Title of Test Results Allowed Note Air Leakage, Infiltration per ASTM E 283 at 75 Pa (1.57 psf) <0.1 L/s/m2 (<0.01 cfm/ft2) 1.5 L/s/m2 (0.3 cfm/ft2) max. 1 Water Penetration, per ASTM E 547 N/A N/A 3 Uniform Load Deflection, per ASTM E 330 taken at retaining angle between fasteners +1440 Pa (+30.08 psf) -1440 Pa (- 30.08 psf) N/A N/A 3 Uniform Load Structural, per ASTM E 330 taken at retaining angle between fasteners +2880 Pa (+60.15 psf) -2160 Pa (-45.11 psf) N/A N/A 3 Optional Performance Water Penetration, per ASTM E 547 at 580 Pa (12.11 psf) Pass No leakage 2 Uniform Load Deflection, per ASTM E 330 taken at retaining angle between fasteners +1920 Pa (+40.10 psf) -1920 Pa (- 40.10 psf) <0.3 mm (<0.01") <0.3 mm (<0.01") Report Only Report Only 4, 6, 7 4, 5, 7 Uniform Load Structural, per ASTM E 330 taken at retaining angle between fasteners +3840 Pa (+80.20 psf) -2880 Pa (-60.15 psf) <0.3 mm (<0.01") <0.3 mm (<0.01") 1.3 mm (0.05") max. 1.3 mm (0.05") max. 6, 7 5, 7 www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 12 of 15 7.0 Test Results: (Continued) Test Specimen #5: PG40 1302 x 2400 (51 x 95)-SKP Title of Test Results Allowed Note Air Leakage, Infiltration per ASTM E 283 at 75 Pa (1.57 psf) <0.1 L/s/m2 (<0.01 cfm/ft2) 1.5 L/s/m2 (0.3 cfm/ft2) max. 1 Water Penetration, per ASTM E 547 N/A N/A 3 Uniform Load Deflection, per ASTM E 330 taken at retaining angle between fasteners +1440 Pa (+30.08 psf) -1440 Pa (- 30.08 psf) N/A N/A 3 Uniform Load Structural, per ASTM E 330 taken at retaining angle between fasteners +2880 Pa (+60.15 psf) -2160 Pa (-45.11 psf) N/A N/A 3 Optional Performance Water Penetration, per ASTM E 547 at 580 Pa (12.11 psf) Pass No leakage 2 Uniform Load Deflection, per ASTM E 330 taken at retaining angle between fasteners +1920 Pa (+40.10 psf) -1920 Pa (- 40.10 psf) <0.3 mm (<0.01") 0.3 mm (0.01") Report Only Report Only 4, 6, 7 4, 5, 7 Uniform Load Structural, per ASTM E 330 taken at retaining angle between fasteners +3840 Pa (+80.20 psf) -2880 Pa (-60.15 psf) <0.3 mm (<0.01") 0.3 mm (0.01") 1.3 mm (0.05") max. 1.3 mm (0.05") max. 6, 7 5, 7 www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 13 of 15 7.0 Test Results: (Continued) Note 1: The tested specimen meets (or exceeds) the performance levels specified in AAMA/WDMA/CSA 101/I.S.2/A440 for air leakage resistance. Note 2: Without insect screen. Note 3: The client opted to start at a pressure higher than the minimum required. Test results are reported under Optional Performance. Note 4: The deflections reported are not limited by AAMA/WDMA/CSA 101/I.S.2/A440 for this product designation. The deflection data is recorded in this report for special code compliance and information only. Note 5: Loads were held for 10 seconds. Note 6: Loads were held for 60 seconds. Note 7: Tape and film were used to seal against air leakage during structural testing. In our opinion, the tape and film did not influence the results of the test. www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 14 of 15 Architectural Testing will service this report for the entire test record retention period. Test records that are retained such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation will be retained by Architectural Testing, Inc. for the entire test record retention period. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written approval of Architectural Testing, Inc. For ARCHITECTURAL TESTING, Inc. ___________________________________________ ________________________________________________ John S. Mayfield Andy Cost Project Manager Laboratory Manager JM:hd Attachments (pages): This report is complete only when all attachments listed are included. Appendix-A: Drawings (7) This report produced from controlled document template ATI 00438, issued 01/31/12. www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Revision 1: 08/22/12 Page 15 of 15 Revision Log Rev. # Date Page(s) Revision(s) 1 08/22/12 2 Corrected Curb outer dimension for Test Specimen #2. 3 Corrected Curb DLO measurements for Test Specimen #3. 5 Corrected Frame DLO measurements for Test Specimen #1 Changed Dome to Pyramid for Test Specimen #2 6 Corrected Frame DLO measurements for Test Specimen #3 7 Changed Pyramid to Dome for Test Specimen #5 Corrected the number of screws located at the midpoint from 12 to 1 in Section 6.0 installation www.archtest.com Test Report No.: C0175.01-801-47 Report Date: 07/11/12 Appendix A Drawings S All TDCMD SCALE 6" = P OUTER GLAZING -.177' THICK CAST ACRYLIC INNER GLAZING -.118' THICK CAST ACRYLIC -- CONT. SILICONE - GE SCS1800 — RETAINING ANGLE - SAPA DIE NO. 2959, 6083-T5 ALUM. —� VINYL GASKET -CENTRAL PLASTICS NO.1522 H8 X 1/2' SST. TEK SCREW -- J POLYURETHANE THERMAL BARRIER EXTRUDED ALUM. FRAME -SAPA DIE NO. 75M, 6063-T5 ALUM. BY JJFASTENING — INSTALLER 1 CONT. SEALANT BY J( CURB OTHERS t FLASHING — 1 q.__ .... _... _. OUTSIDE CURB ROUGH OPENING CIRCLE THE SIZE DESIRED. MODEL TDCMD ROUGH OPENINGS 2028 14 1/2 x 22 1/2 2052 14 1/2 x 46 1/2 2828 22 1/2 x 22 1/2 2841 22 1/2 x 35 1/4 2852 22 1/2 x 46 1/2 2876 22 1/2 x 69 3/4 2896 22 1/2 x 89 3/4 3636 30 1/2 x 30 1/2 3652 30 1/2 x 46 1/2 3660 30 1/2 x 55 1/4 3676 30 1/2 x 69 3/4 3696 30 1/2 x 89 3/4 4242 371/4x371/4 5252 461/2x461/2 5276 46 1/2 x 69 3/4 5296 46 1/2 x 89 3/4 6060 55 1/4 x 55 1/4 7676 69 3/4 x 69 3/4 7696 69 3/4 x 89 3/4 8080 751/4x751/4 9898 92 3/4 x 92 3/4 11/2 CUSTOM SIZES are available upon request. SPECIFICATIONS COMPLETE THE BLANKS BELOW WITH YOUR DESIRED SPECIFICATIONS. Skylights shall be curb -mounted as manufactured by SKYLINE SKY-LITES, 2925 Delta Drive, Colorado Springs, CO 80910, (866)625- 1330. Skylight shall be model TDCMD with thermally formed dual acrylic dome glazings, [bronze / clearl outer dome over [clear / white l inner dome. Curb frame shall be of 6063-T5 aluminum with a .070" thick base frame, incorporating a poured in place polyurethane thermal barrier, and a .062" thick retaining angle. Frame finish shall be [bronze anodized / clear anodized / natural aluminum (mill)] . All corners shall be welded. Vinyl gasket shall be used between the frame and the glazing to form a tight seal. Weep holes shall be provided in the frame. A continuous silicone sealant shall be used between glazings. Skylight shall be completely assembled by the manufacturer and ready for installation directly over curb as provided by others. I hereby certify that all quantities, dimensions and conditions shown on this drawing are correct as shown or as corrected. SIGNATURE DATE REPRESENTING PROJECT: CUSTOMER: CONTRACTOR: QUAN/MODEL: MODE1TDCMD7676 2925 Delta Drive (719) 392-4220 Colorado Springs, CO 80910-1012 (866) 625-1330 skylitmcom Fax: (719) 392-0685 SCALE 6" = I OUTER GLAZING -.236" THICK CAST ACRYLIC INNER GLAZING -.118" THICK CAST ACRYLIC CONT. SILICONE - GE SCSI 800 — RETAINING ANGLE - SAPA DIE NO. 2959,6063-T5 ALUM. VINYL GASKET - CENTRAL PLASTICS NO.1522 N8 X 1/2" SST. TEK SCREW POLYURETHANE THERMAL BARRIER – EXTRUDED ALUM. FRAME -SAPA DIE NO. 7555, 6063-T5 ALUM. —� By t FASTENING — INSTALLER I CONT. SEALANT BY j CURB OTHERS FLASHING — 1/2" --{ I-- 11/2' OUTSIDE CURB ROUGH OPENING CIRCLE TIIE SIZE DESIRED. MODEL TPCMD ROUGH OPENINGS 2028 14 1/2 x 22 1/2 2052 14 1/2 x 46 1/2 2828 221/2x221/2 2841 22 1/2 x 35 1/4 2852 22 1/2 x 46 1/2 2876 22 1/2 x 69 3/4 2896 22 1/2 x 89 3/4 3636 30 1/2 x 30 1/2 3652 30 1/2 x 46 1/2 3660 301/2x551/4 3676 30 1/2 x 69 3/4 3696 30 1/2 x 89 3/4 4242 371/4x371/4 5252 461/2x461/2 5276 46 1/2 x 69 3/4 5296 46 1/2 x 89 3/4 6060 55 1/4 x 55 1/4 7676 69 3/4 x 69 3/4 7696 69 3/4 x 89 374- 8080 75 1/4 x 75 1/4 9898 92 3/4 x 92 3/4 CUS'T'OM SIZES are available upon request. SPECIFICATIONS COMPLETE THE BLANKS BELOW WITH YOUR DESIRED SPECIFICATIONS. Skylights shall be curb -mounted as manufactured by SKYLINE SKY-LITES, 2925 Delta Drive, Colorado Springs, CO 80910, (866)625- 1330. Skylight shall be model TPCMD with thennally formed dual acrylic glazings, 6/12 pitch, [bronze / clear] outer pyramid over [clear / whitel inner pyramid. Curb frame shall be of 6063=T5 aluminum with a .070" thick base frame, incorporating a poured in place polyurethane thermal barrier, and a.062" thick retaining angle. Frame finish shall be [bronze anodized / clear anodized / natural aluminum (mill)] _., . All corners shall be welded. Vinyl gasket shall be used between the frame and the glazing to form a tight seal. Weep holes shall be provided in the frame. A continuous silicone sealant shall be used between glazings. Skylight shall be completely assembled by the manufacturer and ready for installation directly over curb as provided by others. I hereby certify that all quantities, dimensions and conditions shown on this drawing are correct as shown or as corrected. SIGNATURE, DATE REPRESENTING PROJECT: CUSTOMER: CONTRACTOR: QUAN/MODEL: MODEL TPCMD 9898 2925 Delta Drive (719) 392-4220 Colorado Springs, CO 80910-1012 (866) 625-1330 skylltes.com Fax: (719) 3924685 SKYLINE __ SIIF ELITES. P'01!iMID 7, CURB MOUNTED DOUBLE GLAZED TPCMD OUTER GLAZING -.177" SCALE 6" = P THICK CAST ACRYLIC INNER GLAZING -.116" THICK CAST ACRYLIC CONT. SILICONE • GE SGS1800 — RETAINING ANGLE - SAPA DIE NO. 2959, 6063-T5 ALUM. —� VINYLGASKET- CENTRAL PLASTICS NO. 15U #8X 1/2" SST. TEK SCREW — POLYURETHANE THERMAL BARRIER EXTRUDED ALUM. FRAME -SAPA DIE NO. 7W, 6063-T5 ALUM. By t FASTENING — INSTALLER l CONT. SEALANT BY (JCURB OTHERS IFLASHING — 1/2' ---I I- 11/2' "mea} Ar(—"!.4).:(^.`..1;4 V i V fGch OUTSIDE CURB ROUGH OPENING CIRCLE THE SIZE' DESIRED. MODEL TPCMD ROUGH OPENINGS 2028 14 1/2 x 22 1/2 2052 14 1/2 x 46 1/2 2828 22 1/2 x 22 1/2 2841 22 1/2 x 35 1/4 2852 22 1/2 x 46 I/2 2876 22 1/2 x 69 3/4 2896 22 1/2 x 89 3/4 3636 30 1/2 x 30 1/2 3652 30 1/2 x 46 1/2 3660 30 1/2 x 55 1/4 3676 30 1/2 x 69 3/4 3696 30 1/2 x 89 3/4 4242 37 1/4 x 37 1/4 5252 46 1/2 x 46 1/2 5276 46 1/2 x 69 3/4 5296 46 1/2 x 89 3/4 6060 55 1/4 x 55 1/4 7676 69 3/4 x 69 3/4 7696 69 3/4 x 89 3/4 8080 75 1/4 x 75 1/4 9898 92 3/4 x 92 3/4 CUSTOM SIZES are available upon request. SPECIFICATIONS COMPLETE TIME BLANKS BELOW WITH YOUR DESIRED SPECIFICATIONS. Skylights shall be curb -mounted as manufactured by SKYLINE SKY-LITES, 2925 Delta Drive, Colorado Springs, CO 80910, (866)625- 1330. Skylight shall be model TPCMD with thermally formed dual acrylic glazings, 6/12 pitch, [bronze /clear outer pyramid over [clear / white] inner pyramid. Curb frame shall be of 6063-T5 aluminum with a .070" thick base frame, incorporating a poured in place polyurethane thermal barrier, and a .062" thick retaining angle. Frame finish shall be [bronze anodized / clear anodized / natural aluminum (rill)] All corners shall be welded. Vinyl gasket shall be used between tie frame and the glazing to form a tight seal. Weep holes shall be provided in the frame. A continuous silicone sealant shall be used between glazings. Skylight shall be completely assembled by the manufacturer and ready for installation directly over curb as provided by others. I hereby certify that all quantities, dimensions and conditions shown on this drawing are correct as shown or as corrected. SIGNATURE DATE REPRESENTING PROJECT: CUSTOMER: CONTRACTOR: QUAN/MODEL: MODEL TPCMD 7696 2925 Delta Drive (719) 3924220 Colorado Springs, CO 80910-1012 (866) 625-1330 skylites.corn Fax: (719) 3924685 sato=a.erv� SRP�LIYES� LLC . 4 PVRAMID CURB MOUNTED DOUBLE TPCMD SCALE 6" = P OUTER GLAZING -.118" THICK CAST ACRYLIC INNER GLAZING -.118" THICK CAST ACRYLIC CONT. SILICONE - GE SCS1800 — RETAINING ANGLE - SAPA DIE NO. 2959,6063-T5 ALUM. — VINYL GASKET -CENTRAL PLASTICS NO.1522 #8 X 1/2' SST, TEK SCREW POLYURETHANE THERMAL BARRIER EXTRUDED ALUM. FRAME - SAPA DIE NO, 7555, 6063-T5 ALUM. — BY JJ FASTENING — INSTALLER l CONT. SEALANT BY J CURB OTHERS {FLASHING — 1/2" ---1 f--- 11/2" Es',£Snli71 F(,n,1tC 'g r� Report?" � � �� � 0 P?e'3Z'_,?'t,4L_-.�----_M---a.""y- OUTSIDE CURB ROUGH OPENING CIRCLE THE SIZE DESIRED. MODEL TPCMD ROUGH OPENINGS 2028 14 1/2 x 22 1/2 2052 14 1/2 x 46 1/2 2828 22 1/2 x 22 1/2 2841 22 1/2 x 35 1/4 2852 22 1/2 x 46 t/2 2876 22 1/2 x 69 3/4 2896 22 1/2 x 89 3/4 3636 30 1/2 x 30 1/2 3652 30 1/2 x 46 1/2 3660 30 1/2 x 55 1/4 3676 30 1/2 x 69 3/4 3696 30 1/2 x 89 3/4 4242 37 1/4 x 37 1/4 5252 461/2x461/2 5276 46 1/2 x 69 3/4 5296 46 1/2 x 89 3/4 6060 55 1/4 x 55 1/4 7676 69 3/4 x 69 3/4 7696 69 3/4 x 89 3/4 8080 75 1/4 x 75 1/4 9898 92 3/4 x 92 3/4 CUSTOM SIZES are available upon request. COMPLETE THE BLANKS BELOW WITH YOUR DESIRED SPECIFICATIONS. Skylights shall be curb -mounted as manufactured by SKYLINE SKY-LITES, 2925 Delta Drive, Colorado Springs, CO 80910, (866)625- 1330. Skylight shall be model TPCMD with thermally formed dual acrylic glazings, 6/12 pitch, [bronze / clear] outer pyramid over [clear / white] —__ _ inner pyramid. Curb frame shall be of 6063-T5 aluminum with a,070" thick base frame, incorporating a poured in place polyurethane thermal barrier, and a .062" thick retaining angle. Frame finish shall be [bronze anodized / clear anodized / natural aluminum (mill)] ____.__ ______ _. All comers shall be welded. Vinyl gasket shall be used between the frame and the glazing to form a tight seal. Weep holes shall be provided in the frame. A continuous silicone sealant shall be used between glazungs. Skylight shall be completely assembled by the manufacturer and ready for installation directly over curb as provided by others. I hereby certify that all quantities, dimensions and conditions shown on this drawing are correct as shown or as corrected. SIGNATURE DATE REPRESENTING PROJECT: CUSTOMER: CONTRACTOR: QUAN/MODEL: MODEL TPCMD 2852 2925 Delta Drive (719) 392-0220 Colorado Springs, CO 80910-1012 (866) 625-1330 skylites.cont Fax: (719) 392.4685 '��o S x'y" V E -LITW5- LL . - - [ : „ 01lu f 407 6-1*1��3���-17fAA� TDCMD SCALE 6 = P OUTER GLAZING -.17T THICK CAST ACRYLIC --- INNER GLAZING -.118" THICK CAST ACRYLIC CONT. SILICONE - GE SCS1800 — RETAINING ANGLE - SAPA DIE NO. 2959,6063-T5 ALUM. —� VINYL GASKET - CENTRAL PLASTICS NO.1522 p8 X 112` SST, TEK SCREW POLYURETHANE THERMAL BARRIER EXTRUDED ALUM. FRAME - SAPA DIE NO, 7555, 6063-T5 ALUM. — BY JJ FASTENING — INSTALLER j CONT. SEALANT BY f CURB OTHERS IFLASHING — A ;(4.a"t.,,l'.c,,c;�1L`s1c.>', 6� 5',il: -ut,1171(.7€0u (coo Y¢I -'d ei 3i.a OUTSIDE CURB ROUGH OPENING CIRCLE. THE SIZE DESIRED. MODEL TDCMD ROUGH OPENINGS 2028 14 1/2 x 22 1/2 2052 14 1/2 x 46 1/2 2828 22 1/2 x 22 1/2 2841 22 1/2 x 35 1/4 2852 22 1/2 x 46 1/2 2876 22 1/2 x 69 3/4 2896 22 1/2 x 89 3/4 3636 30 1/2 x 30 1/2 3652 30 1/2 x 46 1/2 3660 30 1/2 x 55 1/4 3676 30 1/2 x 69 3/4 3696 30 1/2 x 89 3/4 4242 37 1/4 x 37 1/4 5252 46 1/2 x 46 1/2 5276 46 1/2 x 69 3/4 5296 46 1/2 x 89 3/4 6060 55 1/4 x 55 I/4 7676 69 3/4 x 69 3/4 7696 69 3/4 x 89 3/4 8080 75 1/4 x 75 1/4 9898 92 3/4 x 92 3/4 112 -� 11/2" a -I CUSTOM SIZES are available upon request. SPECIFICATIONS COMPLETE THE BLANKS BELOWWITH YOUR DESIRED SPECIFICATIONS. Skylights shall be curb -mounted as manufactured by SKYLINE SKY-L1TES, 2925 Delta Drive, Colorado Springs, CO 80910, (866)625- 1330. Skylight shall be model TDCMD with thermally formed dual acrylic dome glazings, [bronze / clear] outer dome over f clear / white] _ _-_ _ inner dome. Curb frame shall be of 6063 -TS aluminum with a .070" thick base frame, incorporating a poured in place polyurethane thermal barrier, and a .062' thick retaining angle. Frame finish shall be [bronze anodized / clear anodized / natural aluminum (mill)] . , All comers shall be welded. Vinyl gasket shall be used between the frame and the glazing to foml a tight seal. Weep holes shall be provided in the frame. A continuous silicone sealant shall be used between glazings. Skylight shall be completely assembled by the manufacturer and ready for installation directly over curb as provided by others. I hereby certify that all quantities, dimensions and conditions shown on this drawing are correct as shown or as corrected. SIGNATURE DATE REPRESENTING PROJECT: CUSTOMER: CONTRACTOR: QUAN/MODEL: MODELTDCMD5296 2925 Delta Drive (719) 3924220 Colorado Springs, CO 80910-1012 (866) 625-1330 skylirmcmn Fax: (719) 392-0685 \ k \\ \ w §2 < < S;a,\ (\ f , \; { `2,; ,j s !},� !w 2 is § \ ;; : - \`�/ Ul \ vi ��jj — ) }\ - /- �>a2«} `\- � §§& , ANODIZING INC. LA MAa015 R, c02± t� i L7 O O 0 o UIQ W LL.. SADA PROFILES, INC. ACCEPTS NO RESPONSIBILITY OR LIABILITY FOR THE PERFORMANCE OF PRODUCTS PRODUCED THEREFROM. SAPA PROFILES, INC. MAKES NO WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE WITH REGARD TO THE EXTRUSIONS 7555 i DIE NUNtl!'R s B-10483 O ORAVIM1G NUNNLR R, - N � o � mow oQw z a Am