HomeMy WebLinkAboutFile Documents.525 E Cooper Ave.0119.2018 (6).ACBKTEST REPORT
Report No.: C0175.01-801-47
Rendered to:
SKYLINE SKY-LITES, LLC
Colorado Springs, Colorado
PRODUCT TYPE: Unit Skylight Plastic Glazed
SERIES/MODEL: TPCMD 9898; TPCMD 7696; TPCMD 2852; TDCMD 7676; TDCMD 5296
SPECIFICATION: AAMA/WDMA/CSA 101/I.S.2/A440-11, NAFS - North American
Fenestration Standard/Specification for Windows, Doors, and Skylights
Test Dates: 06/25/12
Through: 06/29/12
Report Date: 07/11/12
Revision 1: 08/22/12
Architectural Testing
Summary of Results
Summary of Results
Title Test Specimen #1 Test Specimen #2
Primary Product Designator PG40 2477 x 2477 (98 x
98)-SKP
PG40 1892 x 2400 (75 x
95)-SKP
Design Pressure ±1920 Pa (±40.10 psf) ±1920 Pa (±40.10 psf)
Air Infiltration <0.1 L/s/m2 (<0.01 cfm/ft2) <0.1 L/s/m2(<0.01 cfm/ft2)
Water Penetration Resistance Test Pressure 580 Pa (12.11 psf) 580 Pa (12.11 psf)
Summary of Results
Title Test Specimen #3 Test Specimen #4
Primary Product Designator PG100 692 x 1302 (27 x
51)-SKP
PG40 892 x 892 (75 x 75)-
SKP
Design Pressure ±4800 Pa (±100.25 psf) ±1920 Pa (±40.10 psf)
Air Infiltration <0.1 L/s/m2 (<0.01
cfm/ft2) <0.1 L/s/m2(<0.01 cfm/ft2)
Water Penetration Resistance Test Pressure 580 Pa (12.11 psf) 580 Pa (12.11 psf)
Summary of Results
Title Test Specimen #5
Primary Product Designator PG40 1302 x 2400 (51 x 95)-SKP
Design Pressure ±1920 Pa (±40.10 psf)
Air Infiltration <0.1 L/s/m2 (<0.01 cfm/ft2)
Water Penetration Resistance Test Pressure 580 Pa (12.11 psf)
Test Completion Date: 06/29/2012
Reference must be made to Report No. C0175.01-801-47, dated 07/11/12 for complete test
specimen description and detailed test results.
Architectural Testing
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 1 of 15
1.0 Report Issued To: Skyline Sky-Lites, LLC
2925 Delta Drive
Colorado Springs, Colorado 80910
2.0 Test Laboratory: Architectural Testing, Inc.
2865 Market Loop
Southlake, TX 76092
817-410-7202
3.0 Project Summary:
3.1 Product Type: Unit Skylight Plastic Glazed
3.2 Series/Model: TPCMD 9898; TPCMD 7696; TPCMD 2852; TDCMD 7676; TDCMD
5296
3.3 Compliance Statement: Results obtained are tested values and were secured by
using the designated test method(s). Test Specimen #1: PG40 2477 x 2477 (98 x
98)-SKP; Test Specimen #2: PG40 1892 x 2400 (75 x 95)-SKP; Test Specimen
#3: PG100 692 x 1302 (27 x 51)-SKP; Test Specimen #4: PG40 892 x 892 (75 x
75)-SKP; Test Specimen #5: PG40 1302 x 2400 (51 x 95)-SKP.
3.4 Test Dates: 06/25/2012 -06/29/2012
3.5 Test Record Retention End Date: All test records for this report will be retained
until 07/11/2016.
3.6 Test Location: Skyline Sky-Lites, LLC test facility in Colorado Springs, Colorado.
Calibration of test equipment was performed by Architectural Testing in
accordance with AAMA 205-01 "In-Plant Testing Guidelines for Manufacturers and
Independent Laboratories".
3.7 Test Sample Source: The test specimen was provided by the client.
Representative samples of the test specimen(s) will be retained by Architectural
Testing for a minimum of four years from the test completion date.
3.8 Drawing Reference: The test specimen drawings have been reviewed by
Architectural Testing and are representative of the test specimen(s) reported
herein. Test specimen construction was verified by Architectural Testing per the
drawings located in Appendix B. Any deviations are documented herein or on the
drawings.
3.9 List of Official Observers:
Name Company
Dave Norgren Skyline Sky-Lites, LLC
Andy Cost Architectural Testing, Inc.
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 2 of 15
4.0 Test Specification(s):
AAMA/WDMA/CSA 101/I.S.2/A440-11, NAFS - North American Fenestration
Standard/Specification for Windows, Doors, and Skylights
5.0 Test Specimen Description:
5.1 Product Sizes:
Test Specimen #1: PG40 2477 x 2477 (98 x 98)-SKP
Overall Area:
3.1 m² (33.5 ft2)
Width Height
millimeters inches millimeters Inches
Overall size 2477 97-1/2 2477 97-1/2
Retaining angle 2477 97-1/2 2477 97-1/2
Frame outer
dimension 2464 97 2464 97
Curb outer
dimension 2432 95-3/4 2432 95-3/4
Curb DLO 2356 92-3/4 2356 92-3/4
Test Specimen #2: PG40 1892 x 2400 (75 x 95)-SKP
Overall Area:
4.5 m² (48.9 ft2)
Width Height
millimeters inches millimeters Inches
Overall size 1892 74-1/2 2400 94-1/2
Retaining angle 1892 74-1/2 2400 94-1/2
Frame outer
dimension 1880 74 2388 94
Curb outer
dimension 1848 72-3/4 2356 92-3/4
Curb DLO 1772 69-3/4 2280 89-3/4
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 3 of 15
5.0 Test Specimen Description: (Continued)
Test Specimen #3: PG100 692 x 1302 (27 x 51)-SKP
Overall Area:
3.1 m² (33.5 ft2)
Width Height
millimeters inches millimeters Inches
Overall size 692 27-1/4 1302 51.-1/4
Retaining angle 692 27-1/4 1302 51-1/4
Frame outer
dimension 679 26-3/4 1289 50-3/4
Curb outer
dimension 648 25-1/2 1257 49-1/2
Curb DLO 572 22-1/2 1181 46-1/2
Test Specimen #4: PG40 892 x 892 (75 x 75)-SKP
Overall Area:
3.6 m² (38.5 ft2)
Width Height
millimeters inches millimeters Inches
Overall size 1892 74-1/2 1892 74-1/2
Retaining angle 1892 74-1/2 1892 74-1/2
Frame outer
dimension 1880 74 1880 74
Curb outer
dimension 1848 72-3/4 1848 72-3/4
Curb DLO 1772 69-3/4 1772 69-3/4
Test Specimen #5: PG40 1302 x 2400 (51 x 95)-SKP
Overall Area:
3.1 m² (33.6 ft2)
Width Height
millimeters inches millimeters Inches
Overall size 1302 51-1/4 2400 94-1/2
Retaining angle 1302 51-1/4 2400 94-1/2
Frame outer
dimension 1289 50-3/4 2388 94
Curb outer
dimension 1257 49-1/2 2350 92-1/2
Curb DLO 1181 46-1/2 2273 89-1/2
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 4 of 15
5.0 Test Specimen Description: (Continued)
The following descriptions apply to all specimens.
5.2 Frame Construction:
Frame Member Material Description
Frame Aluminum Thermally Broken
Retaining angle Aluminum Aluminum Angle
Joinery Type Detail
Frame corners Welded
Corners were mitered and welded along the
lateral face and on the top face. The joint was
covered with silicone.
Retaining angle
Specimens 1,2,4, and
5
Welded The retaining angle was mitered and welded at
each corner.
Retaining angle
Specimen 3 Welded The retaining angle was notched and bent at
three corners with one corner welded
Retaining angle to
Frame Specimens 1,
2, 4, and 5
#8 x 1/2" self-
tapping pan
head screws
One screw located 3" from each corner and 12"
on center thereafter.
Retaining angle to
Frame Specimen 3
#8 x 1/2" self-
tapping pan
head screws
One screw located 5" from each corner and 1 at
the midpoint of each side.
5.3 Sash Construction: None
5.4 Weatherstripping: No weatherstripping was utilized.
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 5 of 15
5.0 Test Specimen Description: (Continued)
5.5 Glazing: No conclusions of any kind regarding the adequacy or inadequacy of the
glass in any glazed test specimen(s) can be made.
Test Specimen #1: PG40 2477 x 2477 (98 x 98)-SKP
Glazing Type Glazing Glazing Method
Outer Pyramid 0.245" Thick Acrylic Pyramid
Exterior glazed. Secured to the
inner dome with silicone at the
interior and with a retaining
angle at the exterior.
Inner Pyramid 0.110” Thick Acrylic
Pyramid
Exterior glazed with a vinyl
gasket at the interior and
secured to the outer dome with
silicone at the exterior.
Location Quantity Daylight Opening Glass Bite millimeters inches
Frame DLO 1 2356 x 2356 92-3/4 x 92-3/4 1-1/2"
Test Specimen #2 PG40 1892 x 2400 (75 x 95)-SKP
Glazing Type Glazing Glazing Method
Outer Pyramid 0.177" Thick Acrylic Pyramid
Exterior glazed. Secured to the
inner dome with silicone at the
interior and with a retaining
angle at the exterior
Inner Pyramid 0.111" Thick Acrylic Pyramid
Exterior glazed with a vinyl
gasket at the interior and
secured to the outer dome with
silicone at the exterior.
Location Quantity Daylight Opening Glass Bite millimeters inches
Frame DLO 1 1772 x 2280 69-3/4 x 89-3/4 1-1/2"
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 6 of 15
5.0 Test Specimen Description: (Continued)
Test Specimen #3: PG100 692 x 1302 (27 x 51)-SKP
Glazing Type Glazing Glazing Method
Outer Pyramid 0.111" Thick Acrylic Pyramid
Exterior glazed. Secured to the
inner dome with silicone at the
interior and with a retaining
angle at the exterior.
Inner Pyramid 0.111" Thick Acrylic Pyramid
Exterior glazed with a vinyl
gasket at the interior and
secured to the outer dome with
silicone at the exterior.
Location Quantity Daylight Opening Glass Bite millimeters inches
Frame DLO 1 572 x 1181 22-1/2 x 46-1/2 1-1/2"
Test Specimen #4: PG40 892 x 892 (75 x 75)-SKP
Glazing Type Glazing Glazing Method
Outer Dome 0.152" Thick Acrylic Dome
Exterior glazed. Secured to the
inner dome with silicone at the
interior and with a retaining
angle at the exterior.
Inner Dome 0.104" Thick Acrylic Dome
Exterior glazed with a vinyl
gasket at the interior and
secured to the outer dome with
silicone at the exterior.
Location Quantity Daylight Opening Glass Bite millimeters inches
Frame DLO 1 1772 x 1772 69-3/4 x 69-3/4 1-1/2"
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 7 of 15
5.0 Test Specimen Description: (Continued)
Test Specimen #5: PG40 1302 x 2400 (51 x 95)-SKP
Glazing Type Glazing Glazing Method
Outer Dome 0.159" Thick Acrylic Dome
Exterior glazed. Secured to the
inner dome with silicone at the
interior and with a retaining
angle at the exterior with 1-
1/2" glazing bite.
Inner Dome 0.110" Thick Acrylic Dome
Exterior glazed with a vinyl
gasket at the interior and
secured to the outer dome with
silicone at the exterior.
Location Quantity Daylight Opening Glass Bite millimeters inches
Frame DLO 1 1181 x 2273 46-1/2 x 89-1/2 1-1/2"
5.2 Drainage: No drainage was utilized.
5.3 Hardware: No hardware was utilized.
5.4 Reinforcement: No reinforcement was utilized.
5.5 Screen Construction: No screen was utilized.
6.0 Installation:
The specimen was installed onto a 2x6 Spruce-Pine-Fir wood curb. The frame overlap
of the curb allowed for a 1/4" shim space full perimeter. The exterior perimeter of the
skylight was sealed with single sided foam tape between the frame and the curb.
Location Anchor Description Anchor Location
Frame leg
Specimens 1, 2,
4, and 5
#10 x 1-1/2" wood screw 3" from each corner and 12" on
center thereafter.
Frame leg
Specimen 3 #10 x 1-1/2" wood screw
One screw located 5" from each
corner and 1 at the midpoint of
each side.
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 8 of 15
7.0 Test Results: The temperature during testing was 27°C (80°F). The results are
tabulated as follows:
Test Specimen #1: PG40 2477 x 2477 (98 x 98)-SKP
Title of Test Results Allowed Note
Air Leakage,
Infiltration per ASTM E 283
at 75 Pa (1.57 psf)
<0.1 L/s/m2
(<0.01 cfm/ft2)
1.5 L/s/m2
(0.3 cfm/ft2) max. 1
Water Penetration,
per ASTM E 547
N/A N/A 3
Uniform Load Deflection,
per ASTM E 330
taken at retaining angle
between fasteners
+1440 Pa (+30.08 psf)
-1440 Pa (- 30.08 psf)
<0.3 mm (<0.01")
<0.3 mm (<0.01")
Report Only
Report Only
4, 6, 7
4, 5, 7
Uniform Load Structural,
per ASTM E 330
taken at retaining angle
between fasteners
+2880 Pa (+60.15 psf)
-2160 Pa (-45.11 psf)
<0.3 mm (<0.01")
<0.3 mm (<0.01")
1.3 mm (0.05") max.
1.3 mm (0.05") max.
6, 7
5, 7
Optional Performance
Water Penetration,
per ASTM E 547
at 580 Pa (12.11 psf) Pass No leakage 2
Uniform Load Deflection,
per ASTM E 330
taken at retaining angle
between fasteners
+1920 Pa (+40.10 psf)
-1920 Pa (- 40.10 psf)
<0.3 mm (<0.01")
<0.3 mm (<0.01")
Report Only
Report Only
4, 6, 7
4, 5, 7
Uniform Load Structural,
per ASTM E 330
taken at retaining angle
between fasteners
+3840 Pa (+80.20 psf)
-2880 Pa (-60.15 psf)
<0.3 mm (<0.01")
<0.3 mm (<0.01")
1.3 mm (0.05") max.
1.3 mm (0.05") max.
6, 7
5, 7
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 9 of 15
7.0 Test Results: (Continued)
Test Specimen #2: PG40 1892 x 2400 (75 x 95)-SKP
Title of Test Results Allowed Note
Air Leakage,
Infiltration per ASTM E 283
at 75 Pa (1.57 psf)
<0.1 L/s/m2
(<0.01 cfm/ft2)
1.5 L/s/m2
(0.3 cfm/ft2) max. 1
Water Penetration,
per ASTM E 547
N/A N/A 3
Uniform Load Deflection,
per ASTM E 330
taken at retaining angle
between fasteners
+1440 Pa (+30.08 psf)
-1440 Pa (- 30.08 psf)
N/A N/A 3
Uniform Load Structural,
per ASTM E 330
taken at retaining angle
between fasteners
+2880 Pa (+60.15 psf)
-2160 Pa (-45.11 psf)
N/A N/A 3
Optional Performance
Water Penetration,
per ASTM E 547
at 580 Pa (12.11 psf) Pass No leakage 2
Uniform Load Deflection,
per ASTM E 330
taken at retaining angle
between fasteners
+1920 Pa (+40.10 psf)
-1920 Pa (- 40.10 psf)
1 mm (0.04")
<0.3 mm (<0.01")
Report Only
Report Only
4, 6, 7
4, 5, 7
Uniform Load Structural,
per ASTM E 330
taken at retaining angle
between fasteners
+3840 Pa (+80.20 psf)
-2880 Pa (-60.15 psf)
0.3 mm (0.01")
0.3 mm (0.01")
1.3 mm (0.05") max.
1.3 mm (0.05") max.
6, 7
5, 7
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 10 of 15
7.0 Test Results: (Continued)
Test Specimen #3: PG100 692 x 1302 (27 x 51)-SKP
Title of Test Results Allowed Note
Air Leakage,
Infiltration per ASTM E 283
at 75 Pa (1.57 psf)
<0.1 L/s/m2
(<0.01 cfm/ft2)
1.5 L/s/m2
(0.3 cfm/ft2) max. 1
Water Penetration,
per ASTM E 547
N/A N/A 3
Uniform Load Deflection,
per ASTM E 330
taken at retaining angle
between fasteners
+1440 Pa (+30.08 psf)
-1440 Pa (- 30.08 psf)
N/A N/A 3
Uniform Load Structural,
per ASTM E 330
taken at retaining angle
between fasteners
+2880 Pa (+60.15 psf)
-2160 Pa (-45.11 psf)
N/A N/A 3
Optional Performance
Water Penetration,
per ASTM E 547
at 580 Pa (12.11 psf) Pass No leakage 2
Uniform Load Deflection,
per ASTM E 330
taken at retaining angle
between fasteners
+4800 Pa (+100.25 psf)
-4800 Pa (- 100.25 psf)
<0.3 mm (<0.01")
<0.3 mm (<0.01")
Report Only
Report Only
4, 6, 7
4, 5, 7
Uniform Load Structural,
per ASTM E 330
taken at retaining angle
between fasteners
+9600 Pa (+200.50 psf)
-7200 Pa (-150.38 psf)
<0.3 mm (<0.01")
<0.3 mm (<0.01")
2 mm (0.08") max.
2 mm (0.08") max.
6, 7
5, 7
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 11 of 15
7.0 Test Results: (Continued)
Test Specimen #4: PG40 892 x 892 (75 x 75)-SKP
Title of Test Results Allowed Note
Air Leakage,
Infiltration per ASTM E 283
at 75 Pa (1.57 psf)
<0.1 L/s/m2
(<0.01 cfm/ft2)
1.5 L/s/m2
(0.3 cfm/ft2) max. 1
Water Penetration,
per ASTM E 547
N/A N/A 3
Uniform Load Deflection,
per ASTM E 330
taken at retaining angle
between fasteners
+1440 Pa (+30.08 psf)
-1440 Pa (- 30.08 psf)
N/A N/A 3
Uniform Load Structural,
per ASTM E 330
taken at retaining angle
between fasteners
+2880 Pa (+60.15 psf)
-2160 Pa (-45.11 psf)
N/A N/A 3
Optional Performance
Water Penetration,
per ASTM E 547
at 580 Pa (12.11 psf) Pass No leakage 2
Uniform Load Deflection,
per ASTM E 330
taken at retaining angle
between fasteners
+1920 Pa (+40.10 psf)
-1920 Pa (- 40.10 psf)
<0.3 mm (<0.01")
<0.3 mm (<0.01")
Report Only
Report Only
4, 6, 7
4, 5, 7
Uniform Load Structural,
per ASTM E 330
taken at retaining angle
between fasteners
+3840 Pa (+80.20 psf)
-2880 Pa (-60.15 psf)
<0.3 mm (<0.01")
<0.3 mm (<0.01")
1.3 mm (0.05") max.
1.3 mm (0.05") max.
6, 7
5, 7
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 12 of 15
7.0 Test Results: (Continued)
Test Specimen #5: PG40 1302 x 2400 (51 x 95)-SKP
Title of Test Results Allowed Note
Air Leakage,
Infiltration per ASTM E 283
at 75 Pa (1.57 psf)
<0.1 L/s/m2
(<0.01 cfm/ft2)
1.5 L/s/m2
(0.3 cfm/ft2) max. 1
Water Penetration,
per ASTM E 547
N/A N/A 3
Uniform Load Deflection,
per ASTM E 330
taken at retaining angle
between fasteners
+1440 Pa (+30.08 psf)
-1440 Pa (- 30.08 psf)
N/A N/A 3
Uniform Load Structural,
per ASTM E 330
taken at retaining angle
between fasteners
+2880 Pa (+60.15 psf)
-2160 Pa (-45.11 psf)
N/A N/A 3
Optional Performance
Water Penetration,
per ASTM E 547
at 580 Pa (12.11 psf) Pass No leakage 2
Uniform Load Deflection,
per ASTM E 330
taken at retaining angle
between fasteners
+1920 Pa (+40.10 psf)
-1920 Pa (- 40.10 psf)
<0.3 mm (<0.01")
0.3 mm (0.01")
Report Only
Report Only
4, 6, 7
4, 5, 7
Uniform Load Structural,
per ASTM E 330
taken at retaining angle
between fasteners
+3840 Pa (+80.20 psf)
-2880 Pa (-60.15 psf)
<0.3 mm (<0.01")
0.3 mm (0.01")
1.3 mm (0.05") max.
1.3 mm (0.05") max.
6, 7
5, 7
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 13 of 15
7.0 Test Results: (Continued)
Note 1: The tested specimen meets (or exceeds) the performance levels specified in
AAMA/WDMA/CSA 101/I.S.2/A440 for air leakage resistance.
Note 2: Without insect screen.
Note 3: The client opted to start at a pressure higher than the minimum required. Test
results are reported under Optional Performance.
Note 4: The deflections reported are not limited by AAMA/WDMA/CSA 101/I.S.2/A440
for this product designation. The deflection data is recorded in this report for special
code compliance and information only.
Note 5: Loads were held for 10 seconds.
Note 6: Loads were held for 60 seconds.
Note 7: Tape and film were used to seal against air leakage during structural testing. In
our opinion, the tape and film did not influence the results of the test.
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 14 of 15
Architectural Testing will service this report for the entire test record retention period.
Test records that are retained such as detailed drawings, datasheets, representative
samples of test specimens, or other pertinent project documentation will be retained by
Architectural Testing, Inc. for the entire test record retention period.
This report does not constitute certification of this product nor an opinion or endorsement
by this laboratory. It is the exclusive property of the client so named herein and relates
only to the specimen(s) tested. This report may not be reproduced, except in full, without
the written approval of Architectural Testing, Inc.
For ARCHITECTURAL TESTING, Inc.
___________________________________________ ________________________________________________
John S. Mayfield Andy Cost
Project Manager Laboratory Manager
JM:hd
Attachments (pages): This report is complete only when all attachments listed are included.
Appendix-A: Drawings (7)
This report produced from controlled document template ATI 00438, issued 01/31/12.
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Revision 1: 08/22/12
Page 15 of 15
Revision Log
Rev. # Date Page(s) Revision(s)
1 08/22/12 2 Corrected Curb outer dimension for
Test Specimen #2.
3 Corrected Curb DLO measurements for
Test Specimen #3.
5 Corrected Frame DLO measurements
for Test Specimen #1
Changed Dome to Pyramid for Test
Specimen #2
6 Corrected Frame DLO measurements
for Test Specimen #3
7 Changed Pyramid to Dome for Test
Specimen #5
Corrected the number of screws
located at the midpoint from 12 to 1 in
Section 6.0 installation
www.archtest.com
Test Report No.: C0175.01-801-47
Report Date: 07/11/12
Appendix A
Drawings
S
All
TDCMD
SCALE 6" = P
OUTER GLAZING -.177'
THICK CAST ACRYLIC
INNER GLAZING -.118'
THICK CAST ACRYLIC --
CONT. SILICONE - GE SCS1800 —
RETAINING ANGLE - SAPA
DIE NO. 2959, 6083-T5 ALUM. —�
VINYL GASKET -CENTRAL
PLASTICS NO.1522
H8 X 1/2' SST. TEK SCREW -- J
POLYURETHANE THERMAL BARRIER
EXTRUDED ALUM. FRAME -SAPA
DIE NO. 75M, 6063-T5 ALUM.
BY
JJFASTENING —
INSTALLER
1 CONT. SEALANT
BY
J( CURB
OTHERS
t FLASHING —
1
q.__ .... _... _.
OUTSIDE
CURB
ROUGH
OPENING
CIRCLE THE SIZE DESIRED.
MODEL
TDCMD
ROUGH
OPENINGS
2028
14 1/2 x 22 1/2
2052
14 1/2 x 46 1/2
2828
22 1/2 x 22 1/2
2841
22 1/2 x 35 1/4
2852
22 1/2 x 46 1/2
2876
22 1/2 x 69 3/4
2896
22 1/2 x 89 3/4
3636
30 1/2 x 30 1/2
3652
30 1/2 x 46 1/2
3660
30 1/2 x 55 1/4
3676
30 1/2 x 69 3/4
3696
30 1/2 x 89 3/4
4242
371/4x371/4
5252
461/2x461/2
5276
46 1/2 x 69 3/4
5296
46 1/2 x 89 3/4
6060
55 1/4 x 55 1/4
7676
69 3/4 x 69 3/4
7696
69 3/4 x 89 3/4
8080
751/4x751/4
9898
92 3/4 x 92 3/4
11/2 CUSTOM SIZES
are available upon request.
SPECIFICATIONS
COMPLETE THE BLANKS BELOW WITH YOUR DESIRED SPECIFICATIONS.
Skylights shall be curb -mounted as manufactured by SKYLINE SKY-LITES, 2925 Delta Drive, Colorado Springs, CO 80910, (866)625-
1330. Skylight shall be model TDCMD with thermally formed dual acrylic dome glazings, [bronze / clearl outer dome over
[clear / white l inner dome. Curb frame shall be of 6063-T5 aluminum with a .070" thick base frame, incorporating a poured
in place polyurethane thermal barrier, and a .062" thick retaining angle. Frame finish shall be [bronze anodized / clear anodized / natural
aluminum (mill)] . All corners shall be welded. Vinyl gasket shall be used between the frame and the glazing to
form a tight seal. Weep holes shall be provided in the frame. A continuous silicone sealant shall be used between glazings. Skylight shall
be completely assembled by the manufacturer and ready for installation directly over curb as provided by others.
I hereby certify that all quantities, dimensions and
conditions shown on this drawing are correct as shown
or as corrected.
SIGNATURE DATE
REPRESENTING
PROJECT:
CUSTOMER:
CONTRACTOR:
QUAN/MODEL: MODE1TDCMD7676
2925 Delta Drive (719) 392-4220
Colorado Springs, CO 80910-1012 (866) 625-1330
skylitmcom Fax: (719) 392-0685
SCALE 6" = I
OUTER GLAZING -.236"
THICK CAST ACRYLIC
INNER GLAZING -.118"
THICK CAST ACRYLIC
CONT. SILICONE - GE SCSI 800 —
RETAINING ANGLE - SAPA
DIE NO. 2959,6063-T5 ALUM.
VINYL GASKET - CENTRAL
PLASTICS NO.1522
N8 X 1/2" SST. TEK SCREW
POLYURETHANE THERMAL BARRIER –
EXTRUDED ALUM. FRAME -SAPA
DIE NO. 7555, 6063-T5 ALUM. —�
By
t FASTENING —
INSTALLER
I CONT. SEALANT
BY
j CURB
OTHERS
FLASHING —
1/2" --{ I-- 11/2'
OUTSIDE
CURB
ROUGH
OPENING
CIRCLE TIIE SIZE DESIRED.
MODEL
TPCMD
ROUGH
OPENINGS
2028
14 1/2 x 22 1/2
2052
14 1/2 x 46 1/2
2828
221/2x221/2
2841
22 1/2 x 35 1/4
2852
22 1/2 x 46 1/2
2876
22 1/2 x 69 3/4
2896
22 1/2 x 89 3/4
3636
30 1/2 x 30 1/2
3652
30 1/2 x 46 1/2
3660
301/2x551/4
3676
30 1/2 x 69 3/4
3696
30 1/2 x 89 3/4
4242
371/4x371/4
5252
461/2x461/2
5276
46 1/2 x 69 3/4
5296
46 1/2 x 89 3/4
6060
55 1/4 x 55 1/4
7676
69 3/4 x 69 3/4
7696
69 3/4 x 89 374-
8080
75 1/4 x 75 1/4
9898
92 3/4 x 92 3/4
CUS'T'OM SIZES
are available upon request.
SPECIFICATIONS
COMPLETE THE BLANKS BELOW WITH YOUR DESIRED SPECIFICATIONS.
Skylights shall be curb -mounted as manufactured by SKYLINE SKY-LITES, 2925 Delta Drive, Colorado Springs, CO 80910, (866)625-
1330. Skylight shall be model TPCMD with thennally formed dual acrylic glazings, 6/12 pitch, [bronze / clear] outer pyramid
over [clear / whitel inner pyramid. Curb frame shall be of 6063=T5 aluminum with a .070" thick base frame, incorporating a
poured in place polyurethane thermal barrier, and a.062" thick retaining angle. Frame finish shall be [bronze anodized / clear anodized /
natural aluminum (mill)] _., . All corners shall be welded. Vinyl gasket shall be used between the frame and the
glazing to form a tight seal. Weep holes shall be provided in the frame. A continuous silicone sealant shall be used between glazings.
Skylight shall be completely assembled by the manufacturer and ready for installation directly over curb as provided by others.
I hereby certify that all quantities, dimensions and
conditions shown on this drawing are correct as shown
or as corrected.
SIGNATURE, DATE
REPRESENTING
PROJECT:
CUSTOMER:
CONTRACTOR:
QUAN/MODEL:
MODEL TPCMD 9898
2925 Delta Drive (719) 392-4220
Colorado Springs, CO 80910-1012 (866) 625-1330
skylltes.com Fax: (719) 3924685
SKYLINE __
SIIF ELITES.
P'01!iMID
7,
CURB MOUNTED
DOUBLE GLAZED
TPCMD
OUTER GLAZING -.177" SCALE 6" = P
THICK CAST ACRYLIC
INNER GLAZING -.116"
THICK CAST ACRYLIC
CONT. SILICONE • GE SGS1800 —
RETAINING ANGLE - SAPA
DIE NO. 2959, 6063-T5 ALUM. —�
VINYLGASKET- CENTRAL
PLASTICS NO. 15U
#8X 1/2" SST. TEK SCREW —
POLYURETHANE THERMAL BARRIER
EXTRUDED ALUM. FRAME -SAPA
DIE NO. 7W, 6063-T5 ALUM.
By
t FASTENING —
INSTALLER
l CONT. SEALANT
BY
(JCURB
OTHERS
IFLASHING —
1/2' ---I I- 11/2'
"mea} Ar(—"!.4).:(^.`..1;4
V i V
fGch
OUTSIDE
CURB
ROUGH
OPENING
CIRCLE THE SIZE' DESIRED.
MODEL
TPCMD
ROUGH
OPENINGS
2028
14 1/2 x 22 1/2
2052
14 1/2 x 46 1/2
2828
22 1/2 x 22 1/2
2841
22 1/2 x 35 1/4
2852
22 1/2 x 46 I/2
2876
22 1/2 x 69 3/4
2896
22 1/2 x 89 3/4
3636
30 1/2 x 30 1/2
3652
30 1/2 x 46 1/2
3660
30 1/2 x 55 1/4
3676
30 1/2 x 69 3/4
3696
30 1/2 x 89 3/4
4242
37 1/4 x 37 1/4
5252
46 1/2 x 46 1/2
5276
46 1/2 x 69 3/4
5296
46 1/2 x 89 3/4
6060
55 1/4 x 55 1/4
7676
69 3/4 x 69 3/4
7696
69 3/4 x 89 3/4
8080
75 1/4 x 75 1/4
9898
92 3/4 x 92 3/4
CUSTOM SIZES
are available upon request.
SPECIFICATIONS
COMPLETE TIME BLANKS BELOW WITH YOUR DESIRED SPECIFICATIONS.
Skylights shall be curb -mounted as manufactured by SKYLINE SKY-LITES, 2925 Delta Drive, Colorado Springs, CO 80910, (866)625-
1330. Skylight shall be model TPCMD with thermally formed dual acrylic glazings, 6/12 pitch, [bronze /clear outer pyramid
over [clear / white] inner pyramid. Curb frame shall be of 6063-T5 aluminum with a .070" thick base frame, incorporating a
poured in place polyurethane thermal barrier, and a .062" thick retaining angle. Frame finish shall be [bronze anodized / clear anodized /
natural aluminum (rill)] All corners shall be welded. Vinyl gasket shall be used between tie frame and the
glazing to form a tight seal. Weep holes shall be provided in the frame. A continuous silicone sealant shall be used between glazings.
Skylight shall be completely assembled by the manufacturer and ready for installation directly over curb as provided by others.
I hereby certify that all quantities, dimensions and
conditions shown on this drawing are correct as shown
or as corrected.
SIGNATURE DATE
REPRESENTING
PROJECT:
CUSTOMER:
CONTRACTOR:
QUAN/MODEL: MODEL TPCMD 7696
2925 Delta Drive (719) 3924220
Colorado Springs, CO 80910-1012 (866) 625-1330
skylites.corn Fax: (719) 3924685
sato=a.erv�
SRP�LIYES� LLC
. 4
PVRAMID
CURB MOUNTED
DOUBLE
TPCMD
SCALE 6" = P
OUTER GLAZING -.118"
THICK CAST ACRYLIC
INNER GLAZING -.118"
THICK CAST ACRYLIC
CONT. SILICONE - GE SCS1800 —
RETAINING ANGLE - SAPA
DIE NO. 2959,6063-T5 ALUM. —
VINYL GASKET -CENTRAL
PLASTICS NO.1522
#8 X 1/2' SST, TEK SCREW
POLYURETHANE THERMAL BARRIER
EXTRUDED ALUM. FRAME - SAPA
DIE NO, 7555, 6063-T5 ALUM. —
BY
JJ FASTENING —
INSTALLER
l CONT. SEALANT
BY
J CURB
OTHERS
{FLASHING —
1/2" ---1 f--- 11/2"
Es',£Snli71 F(,n,1tC 'g
r�
Report?" � � �� � 0
P?e'3Z'_,?'t,4L_-.�----_M---a.""y-
OUTSIDE
CURB
ROUGH
OPENING
CIRCLE THE SIZE DESIRED.
MODEL
TPCMD
ROUGH
OPENINGS
2028
14 1/2 x 22 1/2
2052
14 1/2 x 46 1/2
2828
22 1/2 x 22 1/2
2841
22 1/2 x 35 1/4
2852
22 1/2 x 46 t/2
2876
22 1/2 x 69 3/4
2896
22 1/2 x 89 3/4
3636
30 1/2 x 30 1/2
3652
30 1/2 x 46 1/2
3660
30 1/2 x 55 1/4
3676
30 1/2 x 69 3/4
3696
30 1/2 x 89 3/4
4242
37 1/4 x 37 1/4
5252
461/2x461/2
5276
46 1/2 x 69 3/4
5296
46 1/2 x 89 3/4
6060
55 1/4 x 55 1/4
7676
69 3/4 x 69 3/4
7696
69 3/4 x 89 3/4
8080
75 1/4 x 75 1/4
9898
92 3/4 x 92 3/4
CUSTOM SIZES
are available upon request.
COMPLETE THE BLANKS BELOW WITH YOUR DESIRED SPECIFICATIONS.
Skylights shall be curb -mounted as manufactured by SKYLINE SKY-LITES, 2925 Delta Drive, Colorado Springs, CO 80910, (866)625-
1330. Skylight shall be model TPCMD with thermally formed dual acrylic glazings, 6/12 pitch, [bronze / clear] outer pyramid
over [clear / white] —__ _ inner pyramid. Curb frame shall be of 6063-T5 aluminum with a,070" thick base frame, incorporating a
poured in place polyurethane thermal barrier, and a .062" thick retaining angle. Frame finish shall be [bronze anodized / clear anodized /
natural aluminum (mill)] ____.__ ______ _. All comers shall be welded. Vinyl gasket shall be used between the frame and the
glazing to form a tight seal. Weep holes shall be provided in the frame. A continuous silicone sealant shall be used between glazungs.
Skylight shall be completely assembled by the manufacturer and ready for installation directly over curb as provided by others.
I hereby certify that all quantities, dimensions and
conditions shown on this drawing are correct as shown
or as corrected.
SIGNATURE DATE
REPRESENTING
PROJECT:
CUSTOMER:
CONTRACTOR:
QUAN/MODEL: MODEL TPCMD 2852
2925 Delta Drive (719) 392-0220
Colorado Springs, CO 80910-1012 (866) 625-1330
skylites.cont Fax: (719) 392.4685
'��o
S x'y" V E
-LITW5- LL . - -
[ : „ 01lu f 407
6-1*1��3���-17fAA�
TDCMD
SCALE 6 = P
OUTER GLAZING -.17T
THICK CAST ACRYLIC ---
INNER GLAZING -.118"
THICK CAST ACRYLIC
CONT. SILICONE - GE SCS1800 —
RETAINING ANGLE - SAPA
DIE NO. 2959,6063-T5 ALUM. —�
VINYL GASKET - CENTRAL
PLASTICS NO.1522
p8 X 112` SST, TEK SCREW
POLYURETHANE THERMAL BARRIER
EXTRUDED ALUM. FRAME - SAPA
DIE NO, 7555, 6063-T5 ALUM. —
BY
JJ FASTENING —
INSTALLER
j CONT. SEALANT
BY
f CURB
OTHERS
IFLASHING —
A
;(4.a"t.,,l'.c,,c;�1L`s1c.>', 6� 5',il:
-ut,1171(.7€0u (coo Y¢I -'d ei 3i.a
OUTSIDE
CURB
ROUGH
OPENING
CIRCLE. THE SIZE DESIRED.
MODEL
TDCMD
ROUGH
OPENINGS
2028
14 1/2 x 22 1/2
2052
14 1/2 x 46 1/2
2828
22 1/2 x 22 1/2
2841
22 1/2 x 35 1/4
2852
22 1/2 x 46 1/2
2876
22 1/2 x 69 3/4
2896
22 1/2 x 89 3/4
3636
30 1/2 x 30 1/2
3652
30 1/2 x 46 1/2
3660
30 1/2 x 55 1/4
3676
30 1/2 x 69 3/4
3696
30 1/2 x 89 3/4
4242
37 1/4 x 37 1/4
5252
46 1/2 x 46 1/2
5276
46 1/2 x 69 3/4
5296
46 1/2 x 89 3/4
6060
55 1/4 x 55 I/4
7676
69 3/4 x 69 3/4
7696
69 3/4 x 89 3/4
8080
75 1/4 x 75 1/4
9898
92 3/4 x 92 3/4
112 -� 11/2" a -I CUSTOM SIZES
are available upon request.
SPECIFICATIONS
COMPLETE THE BLANKS BELOWWITH YOUR DESIRED SPECIFICATIONS.
Skylights shall be curb -mounted as manufactured by SKYLINE SKY-L1TES, 2925 Delta Drive, Colorado Springs, CO 80910, (866)625-
1330. Skylight shall be model TDCMD with thermally formed dual acrylic dome glazings, [bronze / clear] outer dome over
f clear / white] _ _-_ _ inner dome. Curb frame shall be of 6063 -TS aluminum with a .070" thick base frame, incorporating a poured
in place polyurethane thermal barrier, and a .062' thick retaining angle. Frame finish shall be [bronze anodized / clear anodized / natural
aluminum (mill)] . , All comers shall be welded. Vinyl gasket shall be used between the frame and the glazing to
foml a tight seal. Weep holes shall be provided in the frame. A continuous silicone sealant shall be used between glazings. Skylight shall
be completely assembled by the manufacturer and ready for installation directly over curb as provided by others.
I hereby certify that all quantities, dimensions and
conditions shown on this drawing are correct as shown
or as corrected.
SIGNATURE DATE
REPRESENTING
PROJECT:
CUSTOMER:
CONTRACTOR:
QUAN/MODEL: MODELTDCMD5296
2925 Delta Drive (719) 3924220
Colorado Springs, CO 80910-1012 (866) 625-1330
skylirmcmn Fax: (719) 392-0685
\ k \\ \
w §2 <
<
S;a,\
(\
f
,
\;
{
`2,;
,j
s
!},�
!w
2 is §
\
;;
:
-
\`�/
Ul
\
vi
��jj
—
)
}\
-
/-
�>a2«}
`\-
�
§§&
,
ANODIZING INC.
LA MAa015
R, c02±
t�
i
L7
O O
0
o UIQ
W
LL..
SADA PROFILES, INC. ACCEPTS NO RESPONSIBILITY OR
LIABILITY FOR THE PERFORMANCE OF PRODUCTS
PRODUCED THEREFROM. SAPA PROFILES, INC. MAKES
NO WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE WITH REGARD TO THE EXTRUSIONS
7555