HomeMy WebLinkAboutFile Documents.501 E Hyman Ave.0079.2018 (4).ACBKJuly 3, 2018 Jodi Smith Facilities Director Pitkin County Via e-mail Re: Ute City Building, 501 E Hyman Ave Unit 106, Aspen, CO Dear Jodi: We have reviewed our structural drawing S-100 (attached) and the work included on that drawing may be carefully demolished without any adverse affects on the structural integrity of the core and shell building. Sincerely, The Office of Studio NYL, Inc. Julian J.B. Lineham PE, SECB, F.SEI, F.ASCE, CEng, FICE Founding Principal Studio NYL Structural Engineers 2995 Baseline Road Suite 314 Boulder, Colorado 80303 Phone 303.558.3145 Web www.studionyl.com Strength Elegance Creativity 07/11/18 07/27/2018 justinh