Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.602 E Cooper Ave.0006.2018 (8).ACBK
EMERGENCY EDG-EDGR Catalog Number Notes Type ORDERING INFORMATION For shortest lead times, configure products using bolded options.Example: EDG 1 R EL Family Housing color Number of faces Letter color Operations Options EDG Surface mount LED edge-lit exit EDGR Recessed LED edge-lit exit (blank)Brushed aluminum W White 1 Single face 2 Double face R Red on clear (single face only)1 G Green on clear (single face only)1 RMR Red on mirror2 GMR Green on mirror2 RW Red on white3 GW Green on white3 (blank)AC only EL Nickel-cadmium battery X2 Lamp wired on two separate AC circuits (specify 120V or 277V)4 SD Self-diagnostics5 (blank)None WM Recessed wall mount6 Accessories: Order as separate item. ELA US12 12” stem kit with brushed aluminum canopy7 ELA W US12 12” stem kit with white canopy7 FEATURES & SPECIFICATIONS INTENDED USE — Suitable for applications requiring attractive edge-lit exit signage, universal installa- tion and low energy consumption. CONSTRUCTION — Extruded brushed aluminum finish. Clear acrylic panels- letters measure 6” high with 3/4” stroke, with 100 ft viewing distance rating, based upon UL 924 standard. For single-face clear panels, EXIT is seen as a reversed image from the back. OPTICS — LEDs mounted on printed circuit board. The typical life of the exit LED lamp is 10 years. The LED operating frequency is 120Hz. ELECTRICAL — Dual voltage input capacity (120/277V). Battery: (EL Option) – Sealed, maintenance free nickel-cadmium battery delivers 90 minutes capacity to emergency lamps. Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostic testing (EL Option Only) for 30 seconds every 30 days and 90 minutes annually. Diagnostic evaluation of LED light source, AC to DC transfer, charging and battery condition. INSTALLATION — EDG – Universal surface (top, end or back) mounting. Canopy provided. EDGR – Recessed mounting. Bar hanger and brackets provided for both new or restricted ceiling access installation applications. Back wall mount (WM) option. Universal directional indicators. Field selected and attached. LISTINGS — UL damp location listed 32°-122°F (0°-50°C) standard. Meets UL924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. WARRANTY — 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx NOTE: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25°C. Specifications subject to change without notice. LED Edge-Lit Exits EDG EDGR LED Lamps Notes 1 For single-face clear panels, EXIT is seen as a reversed image from the back. 2 Available with single and double face. 3 White panel standard for double and single face. 4 Not available with EL and SD options. Both circuits can be energized at the same time. 5 Available with EL option only. 6 Available on EDGR single face only 7 See spec sheet ELA-StemKits. Only available for EDG. All dimensions are inches (centimeters) unless otherwise noted. EDG (surface mount) EDGR (recessed mount) Specifications EDG (End Mount) EDG (Top Mount) Length: 13-5/8 (34.6) Length: 13 (33.0) Depth: 5-1/2(14.0) Depth: 4-5/16 (11.0) Height: 11-1/8 (28.3) Height: 11-3/4 (29.8) Shipping Weight : 4 lbs (1.8 kgs) Shipping Weight : 4 lbs (1.8 kgs) EDG (Back Mount) EDGR Length: 13 (33.0) Length: 13 (33.0) Depth: 3 (7.6) Depth: 1-3/4 (4.4) Height: 11-1/8 (28.3) Height: 8 (20.3) Shipping Weight : 4 lbs (1.8 kgs) Shipping Weight : 6.8 lbs (3.1 kgs) Shipping Weight (WM option) : 8.1 lbs (3.7 kgs) 01/18/2018 EDG-EDGR EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com © 2003-2017 Acuity Brands Lighting, Inc. All rights reserved. Rev. 09/21/17 SPECIFICATIONS KEY FEATURES EDG-EDGR LED, Surface and Recessed Mount Edge-Lit Exits Notes 1 Based on continuous operation. The typical life of the exit LED lamp is 10 years. 2 At 77°F (25°C). 3 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties. 4 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Universal chevron indicators for field selection/installation. Test Switch Pilot Light (Emergency Only) Back Mount End Mount Top Mount 4-5/16(11.0) 11-3/4(29.8) 11-1/8(28.3) 13-5/8(34.6) 12-3/4 (32.4) 5-1/2(14.0) 12-1/8(30.8) 3(7.6) 1/2(1.3) 11-1/8 (28.3) 4-3/8(11.1) 13 (33.0) 12-3/4(32.4) 3/8(1.0) ELECTRICAL Primary Circuit Type Typical LED life1 Supply voltage EDG EDGR Input Watts Max amps. Input Watts Max amps. Red LED AC only 10 years 120 2.5 0.020 3.8 0.030 277 2.8 0.010 4.5 0.014 Green LED AC only 10 years 120 2.2 0.020 3.8 0.030 277 2.2 0.010 4.5 0.020 Red LED emer- gency 10 years 120 3.0 0.030 3.8 0.031 277 3.1 0.010 4.5 0.015 Green LED emergency 10 years 120 2.6 0.020 3.8 0.031 277 2.8 0.010 4.5 0.020 13(33.0)1-3/4(4.4) 8(20.3) EDG EDGR BATTERY (EL option) Sealed Nickel-Cadmium Shelf life2 Typical life2 Maintenance3 Optimum temperature4 3 years 7-9 years none 32-122°F (0-50°C) 14-1/2 (36.8) 3-1/4 (8.3) 2-13/16(7.1) 5-1/2(14.0) 4-1/8(10.5) 15-3/4(40.0)8 (20.3) 13(33.0) EDGR WM option MOUNTING 01/18/2018