Loading...
HomeMy WebLinkAboutFile Documents.520 E Cooper Ave.0085.2018 (16).ACBKLIGHTING SPECS 520 E Cooper Ave unit C7 09/28/18 T F W 604.549.9379 604.549.9555 fluxwerx.com All rights reserved. © Fluxwerx Illumination Inc 2018 Due to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information. NT1-A2018-06 PAGE1 of 6 ® specification 1 2 3 4 5 6 7 8 9 OPTIONS NT1 A D2 - Drywall Trimless shown with (E) Dado Endcap option LED Product Partner 7. DRIVER 8. VOLTAGE 9. LENGTH 4 OPTIONS E1 eldoLED ECO 0-10V Dim 1% E2 eldoLED SOLO 0-10V Dim 0.1% E3 eldoLED ECO DALI 1% E4 eldoLED SOLO DALI Dim 0.1% F1 Factory Non- Dim F2 Factory 0-10V Dim 3% L1 Lutron Hi-Lume 1%-H EcoSystem M 120 - 277 V 3 347 V 3 XX Drywall - Specify 1ft Increments XX Grid - Specify 2ft Increments LC L Corner (2 ft x 2ft) XN X intersection 5 TN T Intersection 5 CW Ceiling to Wall Transition 6 A Alternate Wiring (AV) B Battery Pack 7 C Chicago Plenum E Dado Endcap 8 F 6' Flex Whip (Standalone Only) K Black Trim and Endcap M EM or NL (2nd neutral) P Capsule Endcap 9 T Throughwire Circuit U Throughwire (w / neutral) 1. FAMILY 2. VERSION 3. TRIM / CEILING 4. DISTRIBUTION 5. LIGHT + ENERGY 2 6. CCT NT1 Area 100 Dn L Linear Row P Pattern PATTERN 1 P0 Square P1 Rectangle P2 2-rows | 1-corner P3 3-rows | 2-corner P4 4-rows | 3-corner P5 5-rows | 4-corner D1 Drywall - Trim Flange D2 Drywall - Trimless D3 Drywall - Drop Radius D4 Drywall - Drop Square G1 Grid - 9/16" or 15/16" Flat-T G1 9/16" Tegular or Bolt-Slot G1 4" Armstrong TechZone® or 4" USG Logix® W2 Wall - Trimless A Asymmetric A 450 lm + 5w/ft B 550 lm + 6w/ft 30 3000 K 35 3500 K 40 4000 K Luminaire NOTCH 2 - Area 100 Dn Area Asymmetric (NT1-A)Type Project Product Notes Performance Summary 100 Down Asymmetric A B Light (lm)450 550 Energy (W)5.0 6.0 Efficacy (lm/W)93 91 Color Rendering (CRI)80+80+ Color Accuracy (SDCM)< 2 < 2 L70 Estimate (h)200,000 200,000 Lumen Maintenance per TM21 ( @ 60,000 h)L90 L90 Summary values are nominal and based on 4000K CCT. Specification DataNOTCH 2 Area Asymmetric - NT1-A NOTES 1 Other pattern options available. See page 4 and/or consult factory. 2 Add 1w/ft for 347V with E1-4/L1 3 347 V Driver for F1/F2 347 V Transformer & Driver for E1-4 L1 4 Minimum is 2 feet 5 Available in D2 or W2 trim options. 6 Available in D2 trim option. Wall leg Light + Energy default is "A". Call factory for options. 7 Available for 120-277V in linear 4 or 8 foot. 8 Available with D2 trim option. Default option is to install in one end only. Call factory for options. 9 Available in D2, D3 and W2 trim options. 520 COOPER R1 (a)4' (b)8' 09/28/18 All rights reserved. © Fluxwerx Illumination Inc 2018 Due to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information. PAGE2 of 6NT1-A2018-06 NOTCH 2 - AREA 100 DN ASYMMETRIC® NOTE: Use G1 for 4" Armstrong TechZone® or 4" USG Logix® TRIM OPTIONS D2 - Drywall Trimless OPTIONAL Capsule Endcap OPTIONAL Dado Endcap TRIMLESS D3 - Drywall Drop Radius D4 - Drywall Drop Square DROP TRIM OPTIONAL Capsule Endcap G1 - 9/16" Grid Flat T G1 - 15/16" Grid Flat T G1 - 9/16" Tegular | Slot Grid GRID D1 - Drywall Trim Flange TRIM Electrical • Integral high efficiency drivers 120 – 277 V or 347 V; 50 - 60 Hz • Optional Battery Pack • Optional flex whip: 6’ prewired for standalone • Surge Protection: Meets ANSI C82.11 spec and ANSI/IEEE C62.41 • Inrush Current: Meets NEMA 410 Environmental • Designed for use in damp or dry indoor environments with room side operating temperatures of 0 - 30° C (32 - 86° F) Warranty • 5 year limited warranty on all components and workmanship Independent Testing • IESNA LM79 • IESNA LM80 (LED@ 10,000 h) Approvals • UL Listed (USA + Canada) • CCEA Chicago Plenum • Lighting Facts® • IC Rated Optical • Anidolic optical system with linear light extraction elements • Precision extruded high transmittance clear acrylic lenses • Long life LED system designed for TM21 lumen maintenance ≥ L90 @ 60,000 h • Available in CCTs 3000 K, 3500 K or 4000 K with CRI ≥ 80 and R9 ≥ 0, all with color accurate binning ≤ 2 SDCM Construction • 20 ga. satin coat steel housing • Extruded aluminum flange options available for drywall trim, trimless and t-bar grid ceilings 09/28/18 All rights reserved. © Fluxwerx Illumination Inc 2018 Due to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information. PAGE3 of 6NT1-A2018-06 NOTCH 2 - AREA 100 DN ASYMMETRIC® inches (mm)DIMENSIONS 15/16" | 9/16" flat grid 9/16"bolt slot tegular grid 9/16" tegular g1 g1 g1 Grid (g1) is compatible with 4" Armstrong TechZone® and 4" USG Logix® Ceiling Systems 2.35" (60) 4" (102) (On Center)(On Center)(On Center) 0.94" (24) 2.35" (60) 4" (102) 0.56" (14) 2.35" (60) 4" (102) 0.56" (14) 4.68" (119) 4.68" (119) 4.68" (119) drywall drop trim d3 (RADIUS/ SQUARE) 2.35" (60) 5.13" (130)0.25" (6) 4.80" (122) drywall trim flange d1 3.5" (88.9) 2.35" (60) 4.37" (111) drywall trim flange d1 3.5" (88.9) 2.35" (60) drywall trim flange d1 3.5" (88.9) 2.35" (60) drywall trim flange drywall trimless d1 d2 3.5" (88.9) 2.35" (60) 4.25" (108) 2.35" (60) 2.7" (67) 4" (101.6) 5.13" (130) 4.68" (119) 4.80" (122)Finished Dado Dimensions d4+ wall - trimless cross section view w2 2.35" (60)4.25" (108) 5.13" (130) 4.80" (122) 09/28/18 All rights reserved. © Fluxwerx Illumination Inc 2018 Due to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information. PAGE4 of 6NT1-A2018-06 NOTCH 2 - AREA 100 DN ASYMMETRIC® CONTINUOUS ROWS + STANDALONE FIXTURES Continuous rows are available in nominal 1’ increments in drywall ceilings and in 2’ increments on-grid for T-bar ceilings. Standalone fixtures are available in 2’, 3’, 4’, or 8’ sizes. (drywall only)Note: Run lengths are nominal and vary with ceiling condition and trim selections. INTERSECTING FIXTURES Intersecting sections can be used as standalone fixtures or combined with rows to create illuminated ceiling designs and patterns of light in limitless combinations. T-INTERSECTION (TN) - CEILING ONLY X-INTERSECTION (XN) - CEILING ONLY 2' 2' 2' 45" CORNER (LC) - WALL OR CEILING 2' 2' CEILING TO WALL TRANSITION (CW) 2' 3' 4' 8' 20" 20" X’ For patterns, design your own layout using the trim and corner options available or choose from our patterns for simpler specification. PATTERNS NOTE: Minimum corner to corner length – 4ft in drywall (4' x 4' square) | 6ft in grid (6' x 6' square) P0 - SQUARE A A P1 - RECTANGLE A B P2 - 2 SIDES | 1 CORNER A B P3 - 3 SIDES | 2 CORNER A B C P4 - 4 SIDES | 3 CORNER D A B C 09/28/18 All rights reserved. © Fluxwerx Illumination Inc 2018 Due to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information. PAGE5 of 6NT1-A2018-06 NOTCH 2 - AREA 100 DN ASYMMETRIC® 21.31" (541) 4.25" (108) 23.04" (585) 0.88" (22) 1/4 - 20 THREADED ROD MOUNTING SLOT 45.31" (1151) 47.04" (1195) 2 FT *TYPICAL For D1: 4.0" (102) 4.25" (108) For D1: 4.0" (102) DRYWALL CUT OUT DIMENSIONS inches (mm) 43.46" (1104) 45.12" (1146) INSTALLATION NOTES: • Cutout dimensions apply to all drywall trim options. • For patterns, squares and rectangles, use centerline dimensions with trim cutout width to determine the opening. • A minimum depth of 5" above ceiling plane or behind wall plane is required. • Threaded rod or lag bolt mounting is required for ceiling installations only: - Ensure 1/4 -20 threaded rod length is cut between 3.25" - 4.25" above finished ceiling plane - 2 threaded rods required for each linear housing (3 for Corner and T's, 4 for X housing). CORNER T - INTERSECTION 22.56" (573) 21.73" (552) 45.12" (1146) 43.46" (1104) X - INTERSECTION 22.56" (573) 4.25" (108) 21.73" (552) 21.31" (541) 33.81" (859) 23.04" (585) 35.54" (903) 45.31" (1151) 94.25" (2394) 96" (2438) 47.04" (1195) Example of a drywall cutout for a 17' run (8')(4')(3')(2') 0.5" (13) 0.5" (13)ENDCAP ALLOWANCE (See note above) 4.25" (108) For D1: 4.0" (102) CW - INTERSECTION 20.75" (527) 22.56" (573) 0.88" (22) USE EITHER MOUNTING CORNER 4.25" (108) For D1: 4.0" (102) 0.88" (22) DIMENSION TO 1/4 - 20 THREADED ROD MOUNTING SLOT 20.22" (514) 20.22" (514) 4.25" (108) 19.35" (492) To determine the overall drywall ceiling cutout length, add an endcap allowance to each end of a straight run, or final leg of an open pattern, as follows: standard flat endcap (D1-D4) - 1/2”; Capsule endcap - 1-3/4”; Dado endcap - 3/16”. For corner legs of a pattern, DO NOT add an endcap allowance. Instead, use centerline dimensions and the relevant cutout width for your trim to determine the opening. 4 FT ENDCAP ALLOWANCE (See note above) Mounts Mounts Mounts Housing Housing Housing Cutout Length Cutout Width Cutout Width Cutout Width Cutout Width Cutout Width Cutout Width 33.81" (859) 35.54" (903) 94.25" (2394) 96" (2438) 4.25" (108) For D1: 4.0" (102) 4.25" (108) For D1: 4.0" (102) 3 FT 8 FT Mounts Mounts Mounts Mounts Mounts Housing Housing Housing Housing Housing Housing Housing Cutout Width Cutout Width 202.62" (51 47) 09/28/18 All rights reserved. © Fluxwerx Illumination Inc 2018 Due to continuous product improvements, specifications and dimensions are subject to change without notice. Certain options have limited compatibility with some other product selections. Consult www.fluxwerx.com for most current technical information. PAGE6 of 6NT1-A2018-06 NOTCH 2 - AREA 100 DN ASYMMETRIC® Integrating Sphere and Photometric results at 4000K by an independent accredited testing laboratory per IES LM-79-2008 and ANSI C78.377-2011. Results for 3000K, 3500K scaled based on integrating sphere results for NT1-A 23W (B) and NT1-B. Candlepower Distribution scaled per total lumens of Integrating Sphere results. Light + Energy B - 550 lm + 6.0w/ft Description Version NT1-AB40 4ft luminaire 100 Dn, B Lumens CCT 4000 KReport11921916.07 Light + Energy A - 450 lm + 5.0w/ft Description Version NT1-AA40 4ft luminaire 100 Dn A Lumens CCT 4000 KReport11596156.01 Performance Summary Light Energy Efficacy Color Accuracy (lm)(W)(lm/W)(CRI)(R9)(SDCM) CCT Color Temperature 4000 K 1776 19.15 92.8 82.8 6.3 < 2 3500 K 1732 19.15 90.4 82.8 6.3 < 2 3000 K 1687 19.15 88.1 82.9 5.9 < 2 Performance Summary Light Energy Efficacy Color Accuracy (lm)(W)(lm/W)(CRI)(R9)(SDCM) CCT Color Temperature 4000 K 2123 23.3 91.1 82.8 6.3 < 2 3500 K 2070 23.3 88.8 82.8 6.3 < 2 3000 K 2017 23.3 86.6 82.9 5.9 < 2 VerticalAngle Horizontal Angle ZonalLumens0°22.5°45°67.5°90° 0°411 411 411 411 411 5°412 418 424 428 429 40 15°400 421 582 715 759 134 25°376 521 812 943 973 244 35°340 622 886 926 918 328 45°293 661 808 747 673 354 55°237 621 635 333 281 303 65°173 509 264 161 150 221 75°105 261 104 83 79 124 85°36 37 20 20 20 30 90° 95° 105° 115° 125° 135° 145° 155° 165° 175° 180° VerticalAngle Horizontal Angle ZonalLumens0°22.5°45°67.5°90° 0°491 491 491 491 491 5°493 500 507 511 513 47 15°478 503 695 854 907 160 25°449 623 971 1127 1164 292 35°407 744 1060 1107 1098 392 45°351 791 966 893 804 423 55°283 743 759 398 336 362 65°207 608 316 192 179 264 75°126 312 125 100 94 149 85°43 44 24 23 24 35 90° 95° 105° 115° 125° 135° 145° 155° 165° 175° 180° CANDLEPOWER DISTRIBUTION CANDLEPOWER DISTRIBUTION LUMEN SUMMARY LUMEN SUMMARY LUMINANCE DATA (CD/M2) LUMINANCE DATA (CD/M2) CO-EFFICIENTS OF UTILIZATION CO-EFFICIENTS OF UTILIZATION Zone Lumens %Lamp %Fixture 0-30°417 N.A.24 0-60°1402 N.A.79 0-90°1776 N.A.100 90-180°0 N.A.0 0-180°1776 N.A.100 Zone Lumens %Lamp %Fixture 0-30°499 N.A.24 0-60°1676 N.A.79 0-90°2123 N.A.100 90-180°0 N.A.0 0-180°2123 N.A.100 VerticalAngle 0°45°90° 45°5810 16012 13324 55°5783 15510 6865 65°5747 8760 4955 75°5688 5650 4248 85°5738 3198 3214 VerticalAngle 0°45°90° 45°6945 19142 15927 55°6914 18540 8208 65°6871 10470 5926 75°6797 6754 5076 85°6863 3809 3841 TotalLuminaire TotalLuminaire Floor 20 Ceiling 80 70 50 30 10 0 Wall 70 50 30 10 70 50 10 50 10 50 10 50 10 0 0 119 119 119 119 116 116 116 111 111 106 106 102 102 100 1 109 104 99 95 106 101 94 97 91 93 88 90 86 83 2 98 90 83 77 96 88 76 85 74 81 73 78 71 69 3 89 79 70 64 87 77 63 74 62 71 61 69 60 57 4 82 69 60 53 79 68 53 65 52 63 51 61 51 49 5 75 62 52 45 73 60 45 58 45 56 44 54 44 41 6 69 55 46 39 67 54 39 52 39 51 38 49 38 36 7 64 50 41 34 62 49 34 47 34 46 34 44 33 31 8 59 45 36 30 57 44 30 43 30 42 30 40 30 28 9 55 41 33 27 53 40 27 39 27 38 27 37 26 25 10 51 38 30 24 50 37 24 36 24 35 24 34 24 22 Floor 20 Ceiling 80 70 50 30 10 0 Wall 70 50 30 10 70 50 10 50 10 50 10 50 10 0 0 119 119 119 119 116 116 116 111 111 106 106 102 102 100 1 109 104 99 95 106 101 94 97 91 93 88 90 86 83 2 98 90 83 77 96 88 76 85 74 81 73 78 71 69 3 89 79 70 64 87 77 63 74 62 71 61 69 60 57 4 82 69 60 53 79 68 53 65 52 63 51 61 51 49 5 75 62 52 45 73 60 45 58 45 56 44 54 44 41 6 69 55 46 39 67 54 39 52 39 51 38 49 38 36 7 64 50 41 34 62 49 34 47 34 46 34 44 33 31 8 59 45 36 30 57 44 30 43 30 42 30 40 30 28 9 55 41 33 27 53 40 27 39 27 38 27 37 26 25 10 51 38 30 24 50 37 24 36 24 35 24 34 24 22 100% Dn 100% Dn 09/28/18 09/28/18 Photometric performance is measured in accordance with IESNA LM-79. Visit focalpointlights.com for complete photometric data. Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | 773.247.9494 | focalpointlights.com | @focalpointlights Focus™ Wall Wash LED DIMENSIONAL DATA FEATURES PRODUCT OVERVIEW PERFORMANCE Grid Ceiling Shown Grid Drywall Ceiling mounts below housing. Mounting Details 9.01" 228.9mm 6.00" 152.4mm 6.20"157.5mm June 2018 E Lumen Output: 1500-5700lm Wattage: 15-63W LPW: 88-100 SDCM: 3 Low profile LED wall wash provides a glowing transition between wall and ceiling and shadow-free illumination. Housing creates 6" architectural slot with extruded splay to conceal light source from view. Infinite lengths with the ability for pattern creation with 90° inside and outside corners. Ease of installation and maintenance with rough-in housing and separate snap and lock LED light module. Integrated sliding sleeve extends to meet precise dimensions of a finished space with +/- 2" adjustment. Preferred Light: Lighting for better color rendition and human preference. 6' Luminaire, 450 Lumens per foot Delivered Lumens:2700lm Total System Watts: 28W inside corner outside corner optional flanged end detail Wall side R2 09/28/18 fixture: project: PATTERN CONFIGURATIONS (continued on page 3) 10 DAY* ORDERING Luminaire Series FWSL Focus Wall Wash FWSL Shielding FL Frosted Lens FL Lumen Output 250 Lumens per foot 250LF 450 Lumens per foot 450LF 650 Lumens per foot 650LF 800 Lumens per foot 800LF (Not available with DALI) 950 Lumens per foot 950LF (Not available with Lutron or DALI drivers) Color Temperature 2700K, 80+ CRI or 90+ CRI 27K or 927K 3000K, 80+ CRI or 90+ CRI 30K or 930K 3500K, 80+ CRI or 90+ CRI 35K or 935K 4000K, 80+ CRI or 90+ CRI 40K or 940K 3500K, Preferred Light P35K (6" increments only) Circuits 1C Single Circuit 1C Voltage 120/277 UNV UNV 347 Volt 347 (650LF & LD1 driver only) Driver 0-10V - 10% Dimming LD1 0-10V - 1% Dimming L11 Lutron H-Series - 1% Dimming LH1 Lutron 5-Series - 5% Dimming LU5DALI - 1% Dimming D11 Mounting U Universal U Factory Options Air Return AR Chicago Plenum CP Emergency Circuit EC Emergency Battery Pack EM Flanged Ends FL Finish WH Matte White Housing WH Luminaire Length ft in (2' minimum. Leave blank for pattern ordering.)Specify luminaire/row length in 1" increments _ft _in Pattern Options Specify patterns based on wall-to-wall dimensions PAT- (See Pattern Configurations for example) Pattern Example: FWSL-FL-650LF-35K-1C-UNV-LD1-U-WH-PAT-10'-IC-20'-5"-IC-10' SPECIFICATIONS LED System Proprietary linear LED module incorporates premium LEDs on a robust platform to achieve excellent thermal management. Module is available in 2700K, 3000K, 3500K or 4000K with CRI > 80 or CRI>90. LED module and driver are replaceable from below. Construction One-piece, 22Ga. steel rough-in housing powder coated in matte satin white. Housing includes extruded splay in a matte satin white finish and steel alignment bracket. Light engine module constructed with 22Ga. steel and finished in matte satin white. Light engine must be installed after rough-in housing installation. Inside/outside corners and sliding sleeve fabricated with 22Ga. steel and include extruded aluminum splay. Optic Semi-specular aluminum optical reflector with .020" thick diffuser lens. Electrical Light engine module includes driver and wiring harness. Single power drop can power up to 40' or more in a single run. Galvanized feed box with access plate provided for every start of run luminaire and installed in the field. Emergency circuit feed locations are field located by positioning of feed box. Standard 120-277V driver includes 0-10V analog dimming. Power factor > .9. Labels UL and cUL listed. Suitable for Dry or Damp Locations, indoor use only. Suitable for wood ceiling applications. Emergency Battery Bodine BSL-310LP. Emergency output for 90 minutes. Maximum mounting height: 12ft. Finish Polyester powder coat applied over a multi-stage pre–treatment. Lumen Maintenance Reported: L70 > 60,000 hours Calculated: L70 at > 95,000 hours (Derived from EPA TM-21 calculator. Based on typical conditions, consult factory for additional data.) Reliability At Focal Point, our products are designed to stand the test of time. Each luminaire is engineered using superior components, manufactured with the utmost care and rigorously tested. Contact us for reliability data. Warranty LED system rated for operation in ambient environments up to 25°C. 5 year limited warranty. 6' PERFORMANCE CHART PAT-10'-IC-15'-5"-IC-10' start Wall-to-wall dimensions required. Integrated sliding sleeve accommodates +/-2" minimum field adjustment of luminaire. IC - 90º Inside Corner OC - 90º Outside Corner Integrated Sliding Sleeve LED Light Module PAT-8'-OC-10'-IC-18'-3" 18' 3" 8'10'15' 5"10'10'start For more information visit focalpointlights.com/reference or consult factory. Lumens per Foot Delivered Lumens Tested System Watts LPW 250LF 1500 15 100 450LF 2700 28 96 650LF 3900 42 92 800LF 4800 51 90 950LF 5700 63 88 Based on 3500K, 80 CRI, 6' lengths. Lumen Multipliers: Preferred Light = 0.65, 90+ CRI = 0.87. Lumen output may vary + /- 5%. Actual wattage may vary + /- 5%. Focal Point LLC reserves the right to change specifications for product improvement without notification. Options in orange qualify for the Quickship program. 10-day up to 400ft total. Patterns available following drawing approval. Refer to Quickship Guide for complete details. 09/28/18 PAT-10 '-IC-15'-5"-IC-10' U-Pattern Z-Pattern Square/Rectangular Pattern Unique Pattern start PAT-8'-OC-10'-IC-18'-3" KEY IC - 90º Inside Corner OC - 90º Outside Corner - Integrated Sliding Sleeve - LED Light Module 18' 3" 8'10'15' 5"10'10'start start PAT-10 '-IC-15'-5"-IC-10'-IC-15'-5"-IC PAT-8 '-OC-10'-IC-17'-6"-IC-24'-9"-IC-25'-6" 17' 6"24' 9"25' 6" 8'10'15' 5" 15' 5"10'10'start PATTERN CONFIGURATIONS Specify wall-to-wall dimensions in feet and inches. Integrated sliding sleeve accommodates +/- 2" minimum field adjustment of luminaire at corners and end of run. Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | 773.247.9494 | focalpointlights.com | @focalpointlights 09/28/18 Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | 773.247.9494 | focalpointlights.com | @focalpointlight Focus™ Wall Wash EM/EC Guide July 2017 A Run length(ft)Housing Configuration Section Lengths 5 2 + 3 6 3 + 3 7 4 + 3 8 5 + 3 9 6 + 3 10 6 + 4 11 6 + 2 + 3 12 6 + 3 + 3 13 6 + 4 + 3 14 6 + 5 + 3 15 6 + 6 + 3 16 6 + 6 + 4 17 6 + 6 + 2 + 3 18 6 + 6 + 3 + 3 19 6 + 6 + 4 + 3 20 6 + 6 + 5 + 3 21 6 + 6 + 6 + 3 22 6 + 6 + 6 + 4 23 6 + 6 + 6 + 2 + 3 24 6 + 6 + 6 + 3 + 3 25 6 + 6 + 6 + 4 + 3 26 6 + 6 + 6 + 5 + 3 Run length(ft)Housing Configuration Section Lengths 27 6 + 6 + 6 + 6 + 3 28 6 + 6 + 6 + 6 + 4 29 6 + 6 + 6 + 6 + 2 + 3 30 6 + 6 + 6 + 6 + 3 + 3 31 6 + 6 + 6 + 6 + 4 + 3 32 6 + 6 + 6 + 6 + 5 + 3 33 6 + 6 + 6 + 6 + 6 + 3 34 6 + 6 + 6 + 6 + 6 + 4 35 6 + 6 + 6 + 6 + 6 + 2 + 3 36 6 + 6 + 6 + 6 + 6 + 3 + 3 37 6 + 6 + 6 + 6 + 6 + 4 + 3 38 6 + 6 + 6 + 6 + 6 + 5 + 3 39 6 + 6 + 6 + 6 + 6 + 6 + 3 40 6 + 6 + 6 + 6 + 6 + 6 + 4 41 6 + 6 + 6 + 6 + 6 + 6 + 2 + 3 42 6 + 6 + 6 + 6 + 6 + 6 + 3 + 3 43 6 + 6 + 6 + 6 + 6 + 6 + 4 + 3 44 6 + 6 + 6 + 6 + 6 + 6 + 5 + 3 45 6 + 6 + 6 + 6 + 6 + 6 + 6 + 3 46 6 + 6 + 6 + 6 + 6 + 6 + 6 + 4 47 6 + 6 + 6 + 6 + 6 + 6 + 6 + 2 + 3 48 6 + 6 + 6 + 6 + 6 + 6 + 6 + 3 + 3 DEFAULT LOCATIONS • By default, EM/EC are located at the end (last section) of a run when one EM/EC location is specified, and at the start and end when two locations are specified. • EM/EC illuminate entire sections from 2' to 8' in length. • Feed location is at start of run. All EC's are fed individually at the end of each fixture segment. 2 EM/EC – START & END OF RUN Ordering example: FWSL-FL... 2EM-WH-28ft 1 EM/EC – END OF RUN Ordering example: FWSL-FL... 1EM-WH-28ft ONE EM IN 3RD SECTION Ordering example: FWSL-FL... 1EM-3-WH-34ft THREE EM IN 1ST, 3RD AND 6TH SECTIONS Ordering example: FWSL-FL... 3EM-1-3-6-WH-40ft ALTERNATE LOCATIONS AND QUANTITIES • If more than two locations are required, or specific locations within run need to be specified, indicate in the ordering string. Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 6Section 4 Section 5 Section 1 Section 2 Section 3Section 1 Section 6 Section 7 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 6Section 4 Section 5 Section 1 Section 2 Section 3Section 1 Section 6 Section 7 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 6Section 4 Section 5 Section 1 Section 2 Section 3Section 1 Section 6 Section 7 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 6Section 4 Section 5 Section 1 Section 2 Section 3Section 1 Section 6 Section 7 Section 4 Section 5 Standard run configurations, consult factory for custom configurations. CUSTOM LENGTHS • If partial illumination of emergency section is required, indicate quantity in ordering string and partial illumination in Order Notes. Drawing required. • Longer lead times may apply. 09/28/18 Ballerup Mini Design: C. J. Nørgaard Pedersen & P. Hougaard Nielsen Concept: The light distribution is symmetric and directed downwards. The vertical three-layer handblown glass cylinder provides a soft and comfortable light on the ceiling around the fixture, as well as reducing glare for passers-by. Finish: White, powder coated. White opal glass. Material: Diffuser: Handblown white opal glass. Ring: Die cut steel. Mounting: Semi-recessed: Mounting frame with two extendable hanger bars to be installed prior to closing the ceiling. Ceiling types: Type non-IC or Type IC, accessible and non-accessible ceilings. Ceiling cutout: 4.1” diameter. Weight: Min: 1 lbs. Max: 7 lbs. Compliance: cULus, Damp location. Info notes: Type IC variants are compliant to City of Chicago Environmental Air (CCEA) [Chicago Plenum] and Washington State Energy Code (WESC) standards. R3 09/28/18 PRODUCT OVERVIEW Produc t Code Light s ourc e V olt age Finis h Mount ing Featur es Item number BAL MINI 14W LED/3000K 120-277V/60HZ WHT TYPE IC DIM 0-10V 10000136955 BAL MINI 14W LED/3500K 120-277V/60HZ WHT TYPE IC DIM 0-10V 10000136956 BAL MINI 19W LED/3000K 120-277V/60HZ WHT TYPE NON-IC DIM 0-10V 10000131073 BAL MINI 19W LED/3500K 120-277V/60HZ WHT TYPE NON-IC DIM 0-10V 10000131074 S PAREPART Produc t name:Or der ing number: BALLERUP MINI TRIM 5742586751 09/28/18 Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | 773.247.9494 | focalpointlights.com | @focalpointlight Photometric performance is measured in accordance with IESNA LM-79. Visit focalpointlights.com for complete photometric data. PERFORMANCE Downlight, 12˚ Spot, 3500K Watts Delivered Lumens CBCP 6 500 4362 8 700 6108 12 900 7853 DIMENSIONAL DATA FEATURES ID+ 2.5" LED DOWNLIGHT Small aperture LED fixed downlight. 15° beam is ideal for art and object accenting, additional Beamspreads up to 60° complement any application. Selection of dimming drivers available. Selection of trim styles and finishes to complement any design. Adjustable accent & wall wash also available. clear diffuse reflector matte black reflector warm diffuse reflector titanium silver trimwhite trim black trim downlight trim 6.56"166.2mm 16.13" 409.7mm 1.00"2.59"65.8mm4.00"101.6mmMarch 2017 W bronze trim R4 09/28/18 Focal Point LLC reserves the right to change specifications for product improvement without notification. fixture: project: HOUSING DETAILS HOUSING ORDERINGHousing Series FLS2D ID+ 2.5" Round Housing FLS2D Trim Type Round Flush RFRound Overlap RO Lumen Output 500 Lumens 500L(Not available with NFL distribution. LD1, L11 & D11 drivers only)700 Lumens 700L(NFL & LS available with LD1, L11 & D11 only. SP not available with LH1.) 900 Lumens 900L Distribution 15˚ Spot SP 20˚ Narrow Flood NFL 40˚ Flood FL60˚ Wide Flood WFL Linear Spread Lens LS Voltage 120V 120277V277 Driver0-10V - 1% Dimming L11 0-10V - 10% Dimming LD1Lutron A-Series - 1% EcoSystem Digital L3D (Consult factory for 3-wire control) Lutron H-Series - 1% Dimming LH1 Lutron 5-Series - 5% EcoSystem Digital LU5(900L only)DALI - 1% Dimming D11 Lutron A-Series - Forward Phase LTE (120 only) Housing Type Thermally Protected, Non-IC T IC Rated IC(900L - WFL not available) Factory OptionsBar Hangers BH(T housing only)Chicago Plenum / National Plenum CP (IC housing only)Emergency Battery Pack*EMR (Remote test switch, above ceiling access, T housing & RO trim only) TRIM & LED MODULE Aperture LS2 2.5" Round Aperture LS2 Trim Type RD Round RD Color Temperature 2700K, 90+ CRI 927K 3000K, 90+ CRI 930K 3000K, 80+ CRI 30K3500K, 80+ CRI 35K Optic DN Downlight DN Distribution15˚ Spot SP 20˚ Narrow Flood NFL 40˚ Flood FL60˚ Wide Flood WFLLinear Spread Lens LS Reflector ColorClear Diffuse CDMatte Black BKWarm Diffuse WD Flange FinishWhite WHBlackBKTitanium Silver TSBronzeBR ACCESSORIES(One kit included per order as indicated in Distributon above. Order additional kits to change distribution in the field as needed.)15˚ Spot Kit LS2-SPK 20˚ Narrow Flood Kit LS2-NFLK 40˚ Flood Kit LS2-FLK 60˚ Wide Flood Kit LS2-WFLK Linear Spread Kit LS2-LSK HOUSING SPECIFICATIONS Construction Die-formed housing and integral junction box with (7) 1⁄2" pry outs. Accommodates ceiling thicknesses up to 1". For thicker ceiling consult factory. Die–cast aluminum heat sink designed for maximum thermal dissipation. Fixture will not exceed 5 lb. (T) Thermally protected housing for new construction. Insulation to be kept 3" away from housing. Butterfly brackets allow mounting to ½" emt. Order bar hangers as an accessory. (IC) Insulated ceiling housing for new construction drywall/hard ceiling applications with direct insulation contact. Bar hangers included. Overlap and flush wall wash housing complies with ASTM E-283, air-tight energy codes. Electrical Choice of constant current dimming drivers. Power factor >.9 typical, 50/60 Hz., 350-2080mA. Emergency battery Bodine BSL17C–C2. Emergency output—7 watts for 90 minutes. Labels UL and cUL listed. Suitable for Dry or Damp Locations, indoor use only. Lumen Maintenance Reported: L70 at >36,000 hours Derived from EPA TM-21 calculator. Reliability At Focal Point, our products are designed to stand the test of time. Each luminaire is engineered using superior components, manufactured with the utmost care and rigorously tested. Contact us for reliability data. Warranty LED System rated for operation in ambient environments up to 25°C. 5-year limited warranty. TRIM SPECIFICATIONS LED System Proprietary LED module with one Cree MT-G2 LED. LED features EasyWhite technology for maximum efficacy, color consistency and optical control. Color accuracy within 2 SDCM. Aesthetics Parabolic reflector cone ensures glare free optics. Field-paintable flange. Trim clips pull trim tight to the ceiling. Optics Beamspreads achieved with optical filters. Order accessory kits to easily change distribution in field. PERFORMANCE CHART See Page 3 14.80"376mm 11.56" 293.6mm Thermally Protected, Non-IC (T) 16.13" 409.7mm *includes bar hangers 10.58"268.7mm IC Rated (IC) 5.58" 141.7mm 5.36" 136mm 5.72" 145.2mm 9.08" 230.6mm 6.28" 159.5mm 9.85" 250.2mm 09/28/18 PERFORMANCE CHART Delivered Lumens System Watts Distribution Beamspread Center Beam Candlepower (CBCP) 500 6 SP 15˚4362 6 FL 40˚1038 6 WFL 60˚574 700 8 SP 15˚6108 7 NFL 20˚4288 9 FL 40˚1454 10 WFL 60˚804 900 12 SP 15˚7853 10 NFL 20˚5512 12 FL 40˚1870 14 WFL 60˚1034 *Tested with 3500K Clear Diffuse Reflector. **Lumen output may vary +/- 5%. 0.963 Matte Black Reflector (BK) lumen multiplier. LU5 performance: 900L-SP & LS = 1100 lumens, 900L-NFL = 1200 lumens, 900L-FL = 1015 lumens. 09/28/18 Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | 773.247.9494 | focalpointlights.com | @focalpointlights Photometric performance is measured in accordance with IESNA LM-79. Visit focalpointlights.com for complete photometric data. Seem® 4 LED DIMENSIONAL DATA FEATURES PRODUCT OVERVIEW PERFORMANCE end detail 4.50"114mm4.00" 101.6mm June 2018 Z Lumen Output: 1690-4240lm Wattage: 16-42W LPW: 101-109 SDCM: 3 Narrow extruded aluminum 4" linear direct LED. Individual units and continuous runs in 1' increments. Frosted acrylic lens provides uninterrupted illumination, without pixels or shadows. LED position and lens material optimized to provide the perfect blend of high performance and visual comfort. Choice of output levels to meet a wide variety of application needs. Connected Solutions: Integrates with wired and wireless building lighting control systems. Preferred Light: Lighting for better color rendition and human preference. 4' Flush Lens Nominal output: 375 Lumens per foot Delivered Lumens: 1690lm Total System Watts: 16W wall to ceiling companion wall mount companion recessed companion Consult factory for additional row length information. 20'4' end8' start 95.5"48"96" 24'8' start 8' intermediate 8' intermediate 8' end 95.5"96"96" 16'8' start 8' end 95.5"96" 12'4' end8' start 95.5"48" 1T8, 2T5 12'6' end6' start 71.5"72" 2T8, 1T5MOUNTING INFORMATION perimeter companion P1 09/28/18 Focal Point LLC reserves the right to change specifications for product improvement without notification. fixture: project: DETAILS SPECIFICATIONS LED System Proprietary linear LED module incorporates premium LEDs on a robust platform to achieve excellent thermal management. LEDs are placed to promote a uniform appearance. Available in 2700K, 3000K, 3500K or 4000K with CRI>80 or CRI>90, 3SDCM. LED modules and drivers are replaceable from below. Construction One piece extruded aluminum housing. Die cast aluminum end caps. 2' unit weight: 10 lbs., 3' unit weight: 14 lbs., 4' unit weight: 18 lbs., 5' unit weight: 22 lbs. Optic Reflectors fabricated of 22 Ga. steel finished in High Reflectance White powder coat. Extruded acrylic lens .085" thick with satin finish, up to 8' continuous. Electrical Luminaires are pre–wired with factory installed branch circuit wiring and over-molded quick connects. Standard 120-277V constant current driver includes 0-10V analog dimming. Dimming range 100% to 10%.Power factor > .9. Emergency Output - 10 watts for 90 minutes. Maximum mounting height: 19.2ft. See EM/EC Guide for default locations and ordering details. Labels UL and cUL listed. Suitable for Dry or Damp Locations, indoor use only. Finish Polyester powder coat applied over a multi-stage pre–treatment. Lumen Maintenance Reported: L70 > 61,000 hours Calculated: L70 at > 287,000 hours L90 > 61,000 hours L90 at > 74,000 hours (Derived from EPA TM-21 calculator. Based on typical conditions, consult factory for additional data.) Reliability At Focal Point, our products are designed to stand the test of time. Each luminaire is engineered using superior components, manufactured with the utmost care and rigorously tested. Contact us for reliability data. Warranty LED system rated for operation in ambient environments up to 25°C. 5-year limited warranty. 4' PERFORMANCE CHART Standard Patterns with 90˚ Corners Overall Length ‘B’Overall Length‘A’start start start start start Ordering examples assume A=8’, B=6’ & C=4’ Specify clockwise from start of run. Start of run is always at first specified run length. Order: 8’x6’ ‘L’ Patterns - A’xB’ Order: 6’x8’ Overall Length ‘B’Overall Length‘A’Order: 8’x6’x4’ ‘U’ Patterns - A’xB’xC’ Overall Length‘C’Overall Length‘C’‘B’ Overall Length Overall Length‘A’Order: 8’x6’x4’ Overall Length ‘B’Overall Length‘A’Order: 8’x6’R Rectangular Patterns - A’xB’R ‘A’ Overall LengthOverall Length‘B’For more information visit focalpointlights.com/reference or consult factory. Shielding Lumens per Foot Delivered Lumens Tested System Watts LPW Flush Lens 375LF 1690 16 106 625LF 2810 26 109 875LF 3860 37 105 1000LF 4240 42 101 Based on 3500K, 80 CRI, 4' lengths. Lumen multipliers: Preferred Light = 0.65, 90+ CRI = 0.87. Lumen output may vary +/- 5%. Actual wattage may vary +/- 5%. ORDERING Luminaire Series FSM4LS Seem 4 LED FSM4LS Shielding FLFlush Satin Lens FL Lumen Output275 Lumens per foot 275LF (Not available with Lutron Drivers.)375 Lumens per foot 375LF(Not available with LU5 & LH1 Drivers)625 Lumens per foot 625LF (3' minimum with LU5 & LH1 Drivers)875 Lumens per foot 875LF1000 Lumens per foot 1000LF Color Temperature2700K, 80+ CRI or 90+ CRI 27K or 927K 3000K, 80+ CRI or 90+ CRI 30K or 930K 3500K, 80+ CRI or 90+ CRI 35K or 935K 4000K, 80+ CRI or 90+ CRI 40K or 940K 3500K, Preferred Light P35K(Patterns not available.) Circuit 1C Single Circuit 1C Voltage UNVUNV 120/277 Volt UNV Control System & Dimming Level 0-10V - 10% Dimming LD1 0-10V - 1% Dimming L11Lutron Hi-Lume EcoSystem (LDE1) - 1% Dimming LH1 Lutron 5-Series EcoSystem (LDE5) - 5% Dimming LU5 DALI 1% Dimming D11 Acuity nLight - 1% Dimming NLT1(3' minimum length.) Enlighted Smart Sensor - 1% Dimming ENL1 (3' minimum length.) Osram Connected Lighting Module - 1% Dimming CLM1(3' minimum length. Compatible with Daintree Networks & Osram ENCELIUM and ENCELIUM EDGE systems.) Wattstopper DLM - 1% Dimming DLM1(3' minimum length.) Mounting24" Cable Suspension C24 48" Cable Suspension C48 96" Cable Suspension C96 (Add “P” for Chicago plenum. Eg: CP12) (Specify one of the following in place of “C” J - for 2" canopies at non–feed locations. CS - for sloped ceiling applications.)Surface Mount SM (Not available with DLM1 or NLT1) Factory Options Emergency Circuit _EC(4' minimum. 7' minimum with CLM1, DLM1, ENL1 & NLT1.) Emergency Battery Pack _EM(4' minimum. 7' minimum with CLM1, DLM1, ENL1 & NLT1. See EM/EC Guide for default locations and ordering details.) FinishTitanium Silver TS Matte White Housing WH Luminaire Length(Leave blank for patterns. Lengths are nominal) Specify luminaire/row length in 1' increments X' (Smaller increments available. Consult factory for details.)Pattern Options(3' minimum length) Specify luminaire/row length in 1' increments X' ‘L’ pattern A' x B' ‘U’ pattern A' x B' x C' Rectangular pattern A' x B'R (Consult factory for other pattern options) 09/28/18 Seem® 4 LED CONNECTED SOLUTIONS DETAILS Connected Solution Model #Protocol Compatible Networks*Occupancy Daylight Temperature Reporting Communication to Luminaire Drivers Acuity nLight (NLT1)nEPS-60-IO**nLight nLight Enabled Enabled No Wired eldoLED ECOdrive, eldoLED SOLOdrive Crestron (D11, L11)Specified Driver DALI 0-10V Crestron Zūm Wireless & SpaceBuilder Enabled Enabled No Wired eldoLED ECOdrive (DALI), Philips Xitanium (0-10V) Enlighted Smart Sensor (ENL1)SU-4E-01**Enlighted RF Enlighted Integrated Integrated Yes Wireless Philips SimpleSet, Osram Optotronic Legrand Wattstopper DLM (DLM1)LMFC-011**DLM DLM Enabled Enabled No Wired Philips SimpleSet, Osram Optotronic Lutron EcoSystem (LH1 & LU5)LDE1,** LDE5**EcoSystem Quantum, Energi Savr Node, Energi TriPak Enabled Enabled No Wired Lutron Hi-Lume Lutron 5-Series Osram CLM (CLM1)ZBHA-CLM**ZigBee HA Osram ENCELIUM & ENCELIUM EDGE, Daintree Networks Enabled Enabled No Wireless Osram Optotronic *Not all compatible networks may be listed. **For performance data and additional control system details please visit the connected solutions manufacturer websites. Primary drivers are listed in bold. To specify a particular driver please consult factory. †Controls systems supplied by others. Focal Point provides flexibility in meeting the needs of each project by integrating with several building lighting control systems. A variety of sensors, drivers and other components can be specified that allow the luminaires to communicate with wired and wireless networks. All zoning can be digitally reconfigured through the application software. Daylight harvesting, occupancy sensing, integration with HVAC systems, and individual controls enable the monitoring and modulating of light levels and temperature in order to save energy, reduce costs and maximize occupants’ comfort. All Connected Solutions luminaires require a compatible building control system.† Enlighted smart sensor allows for occupancy sensing, daylight harvesting, energy usage, temperature and light level control. Communicates wirelessly with the Enlighted network. Enlighted Smart Sensor - 1% Dimming (ENL1) Enlighted Model #SU-4E-01 Connected Lighting Module (CLM) enables each luminaire to be independently controlled and configured. Communicates wirelessly with Daintree Networks®, Osram ENCELIUM®, Osram ENCELIUM EDGE™, and other networks using the ZigBee® HA communication protocol to allow for on/off and dimming functionality, occupancy sensing and multi-zone daylight harvesting. Osram CLM - 1% Dimming (CLM1) Osram Model #ZBHA-CLM DIM Serial labels will be provided on outside of luminaires and control unit. A Digital Lighting Management (DLM) system that provides two-way wired communication between networked luminaires and control system to allow for on/off and dimming functionality, occupancy sensing and multi-zone daylight harvesting. Wattstopper DLM - 1% Dimming (DLM1) Wattstopper Model #LMFC-011 Segment Network Wire provided between segments of a run. Segment Network Wire provided by others at start of run. Serial labels will be provided on outside of luminaires and control unit. nLight® provides a two-way wired digital lighting system allowing for on/off and dimming functionality, occupancy sensing, and multi-zone daylight harvesting. Acuity nLight - 1% Dimming (NLT1) Acuity Model #nEPS-60-IO CAT-5 Cable provided between segments of a run. CAT-5 Cable provided by others at start of run. Serial labels will be provided on outside of luminaires and control unit. A two-way digital network that enables on/off and dimming functionality, occupancy sensing, and multi-zone daylight harvesting working with Quantum®, Energi Savr Node™, and Energi TriPak® using EcoSystem® communication protocol. Lutron Hi-Lume EcoSystem - 1% Dimming (LH1)Lutron Model #LDE1 Lutron 5-Series EcoSystem - 5% Dimming (LU5)Lutron Model #LDE5 Connections located under access panel. Connections located under access panel. Runs Runs A two-way digital network that enables on/off and dimming functionality, occupancy sensing, and multi-zone daylight harvesting. Communicates with Zūm wireless and SpaceBuilder working with Zūm hub scheduling or FUSION management. DALI - 1% Dimming (D11)0-10V - 1% Dimming (L11)Note: 0-10V is not a digital network but is compatible with Creston Zūm™ system. 09/28/18 Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | 773.247.9494 | focalpointlights.com | @focalpointlight Seem® EM/EC Guide FSM1, FSM1S, FSM1W, FSM2L-FL, FSM2L-FL2, FSM2LS, FSM2LW, FSM4L-FL/SR/SRXP, FSM4L-FL2, FSM4LS, FSM4LW, FSM4LP, FSM6L-FL/SR/SRXP* April 2018 C Run length(ft)Housing Configuration Section Lengths 9 5 + 4 10 6 + 4 11 7 + 4 12 8 + 4 13 8 + 5 14 8 + 6 15 8 + 7 16 8 + 8 17 8 + 5 + 4 18 8 + 6 + 4 19 8 + 7 + 4 20 8 + 8 + 4 21 8 + 8 + 5 22 8 + 8 + 6 23 8 + 8 + 7 24 8 + 8 + 8 25 8 + 8 + 5 + 4 26 8 + 8 + 6 + 4 27 8 + 8 + 7 + 4 Run length(ft)Housing Configuration Section Lengths 28 8 + 8 + 8 + 4 29 8 + 8 + 8 + 5 30 8 + 8 + 8 + 6 31 8 + 8 + 8 + 7 32 8 + 8 + 8 + 8 33 8 + 8 + 8 + 5 + 4 34 8 + 8 + 8 + 6 + 4 35 8 + 8 + 8 + 7 + 4 36 8 + 8 + 8 + 8 + 4 37 8 + 8 + 8 + 8 + 5 38 8 + 8 + 8 + 8 + 6 39 8 + 8 + 8 + 8 + 7 40 8 + 8 + 8 + 8 + 8 41 8 + 8 + 8 + 8 + 5 + 4 42 8 + 8 + 8 + 8 + 6 + 4 43 8 + 8 + 8 + 8 + 7 + 4 44 8 + 8 + 8 + 8 + 8 + 4 45 8 + 8 + 8 + 8 + 8 + 5 46 8 + 8 + 8 + 8 + 8 + 6 47 8 + 8 + 8 + 8 + 8 + 7 48 8 + 8 + 8 + 8 + 8 + 8 DEFAULT LOCATIONS • By default, EM/EC are located at the end (last section) of a run when one EM/EC location is specified, and at the start and end when two locations are specified. • EM/EC illuminate entire sections from 4' to 8' in length. • Feed location is at start of run. All EC's are fed individually at the end of each fixture segment. 2 EM/EC – START & END OF RUN Ordering example: FSM4L-FL... 2EM-WH-36ft 1 EM/EC – END OF RUN Ordering example: FSM4L-FL... 1EM-WH-36ft ONE EM IN 3RD SECTION Ordering example: FSM4L-FL... 1EM-3-WH-40ft THREE EM IN 1ST, 3RD AND 6TH SECTIONS Ordering example: FSM4L-FL... 3EM-1-3-6-WH-48ft ALTERNATE LOCATIONS AND QUANTITIES • If more than two locations are required, or specific locations within run need to be specified, indicate in the ordering string. Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 6Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5Section 1 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 6Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5Section 1 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 6Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5Section 1 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5 Section 1 Section 2 Section 3 Section 6Section 4 Section 5 Section 1 Section 2 Section 3 Section 4 Section 5Section 1 *Recessed and suspended only. Does not include direct/indirect, pop-down lens or asymmetric options. Standard run configurations, consult factory for custom configurations. CUSTOM LENGTHS • If partial illumination of emergency section is required, indicate quantity in ordering string and partial illumination in Order Notes. Drawing required. • Longer lead times may apply. 09/28/18 OFFICE SYSTEM SPECS 09/28/18 BUDGET PROPOSAL 520 COOPER HIGHLINE + PARTNERS RHIANNON CABALLERO 2732 W. 26th Avenue Unit 105 · Denver CO 80211 520 E COOPER UNIT C7 WALL SPECIFICATIONS AND ACCESSIBLE HARDWARE 09/28/18 September 10, 2018 Ms. Rhiannon Caballero Highline + Partners Kansas City, Kansas Dear Rhiannon: I am delighted to submit this Preliminary Budget for the project at 520 Cooper in Aspen. and potential future locations. This document includes details images, budget pricing, an Executive Summary as an overview, LEED information, as well as information about tax advantages associated with ALUR. I have also included a list of recommendations and considerations for product that would shorten cycle times and facilitate installation. Here are a couple of notes regarding the ALUR Walls and this proposal:  The project is priced as ALUR’s with-post” design, which features vertical framing members adjacent to the drywall at the perimeter of the finished openings and next to any door. The advantage to this configuration is the ability to use the door side post as a conduit for low voltage wire, in the event room schedulers would be used frequently. It also, as Brandi noted on our tour, does help define the doorway, which may be helpful for unfamiliar users. If wood doors are specified. The with-post design will be required. The post-less system may be used otherwise. It is a bit less expensive.  Glass is ½”, tempered, which delivers excellent structure and sound attenuation (STC 36) and can be 10’-0” high, without a clerestory. Only ½” and thicker tempered glass meets the International Building Code standard for deflection.  Frames are quoted as our bronze finish. The original budget was quoted in our standard finish, which is a clear-anodized and bead-blasted aluminum.  The Quote covers finished opening heights between 8’-0” and 9’-0”.  I have quoted a 4’ band of privacy film on each glass lite, to be mounted between 2 and 6’-0” above the finished floor.  The plan includes 24” nibs walls as indicated on the plan.  The budget reflects attachment to braced and blocked soffits. Please do not hesitate to call me, should you have any questions. We look forward to the opportunity to work together with you and your team on this project. Thank you in advance for your consideration. Sincerely, Mike Milligan Mikemilligan.60@gmail.com 720.456.5979 09/28/18 EXECUTIVE SUMMARY Proven Product The ALUR system is a proven design, with many successful installations in place. A visit to one of these installations or a local showroom will happily be arranged, if desired. Safety and Code Compliance ALUR uses only ½” tempered glass, as it is the thickness at which tempered glass complies with the standards established in the International Building Code (IBC) for deflection. This standard exists for the safety of the residents in the building. 3/8” thick glass does not comply. For walls at 9’-6” and the test pressure of 5 pounds per square foot, 3/8” thick glass deflects 3.5”! This is more than 4 times as much as ½” glass. Superior Fit and Finish ALUR components and system reflect the best of finishing processes. Black frames are resin coated for a soft, low-sheen finish, door hardware is beautifully finished and carefully packaged to prevent damage. Framing is produced oversize for perfect fitting in the field to your building. Tolerances for glass are managed in the field, so tall bases and leggy levelers are not necessary. Clean, Silicone-free Joints Polycarbonate joints eliminate unsightly silicone “wet seal,” minimize deflection and provide optimal sound seal; they are 93% clear and will not discolor or shrink over time. The unique tongue and groove design creates a perfectly smooth glass-to-glass connection. I, L, T and 135° and variable-angle joints facilitate a wide variety of configurations. 09/28/18 Minimal, Uninterrupted Framing Sliding doors are completely concealed on the backside of doorframe and have no exposed hardware for a beautiful, streamlined look. Note in this image how the header detail and dimension are unchanged, whether a sliding or pivot doors is utilized. Sound Privacy ALUR was designed for maximum sound attenuation. The ALUR Glass Wall features premium ½” tempered glass, delivering an exceptional 36 STC rating. ALUR’s proprietary tongue and groove polycarbonate “dry joints” provide a perfect glass-to-glass seal. Both top and both ceiling and floor tracks install tight to the surface and have dual gaskets to prevent sound loss. Wall channels have compression gaskets that seal the glass tightly inside the frame. In addition, the sliding doors have gaskets at the top and to one side with a pocket on the closing side post to help reduce sound loss at the door opening. An optional bottom brush seal is also available, but seldom required. Sustainability and Adaptability Glass is produced locally to reduce cost and carbon footprint, while improving project responsiveness. The component nature of ALUR allows sizing to precise measurements and easier delivery into buildings than unitized, pre-built walls. ALUR framing is oversized and trimmed to fit precisely on the jobsite. Glass lights are ordered based on laser measurement of the finished opening size. This innovation allows ALUR to better adapt to uneven floors, walls and even ceilings, and allows the client access to LEED credits, if so desired. 09/28/18 WARRANTY 09/28/18 THOUGHTS AND CONSIDERATIONS Rhiannon, You had mentioned your intent to roll this design out to multiple locations. To this end I am making the following suggestions for product configuration. We want the order cycle to be as short as possible for flexibility with construction schedules. To shorten cycle times: Order once the plan is set. Our framing members are produced 3” over-sized for precise fitting in the field, allowing a small amount of tolerance. Frames and hardware may be ordered as soon as you have finalized the plan, and it makes sense to get the process moving as quickly as possible. Leadtime for the frames is short. Arriving on site in approximately 4 weeks. However, as important is starting the process for documentation and scheduling. Wood doors lengthen lead time Wood doors are beautiful and are specified frequently with glass walls. However, the longer lead times create a bit of the problem within the glass system as like the glass, the doors are not ordered until the site is in a state of finish (framing, drywall, j-bead, and a first coat of mud) that allows laser measurement of the openings. Unlike glass, wood door lead time is 6 to 8 weeks. Glass lead time is 10 to 12 business days. Wood doors also require more fitting and installation time. Wood doors are great. Just need to allow time for them. Communicate for earliest measurement date. The schedule for the glass walls is ultimately dependent upon the construction progress and prompt measurement of the space when it reaches readiness. Apply the system as it is designed. Since you have control over the built environment in most of these instances, a standard can be set for application of the system, as there are conditions, which make the process easier. Items such as how the glass meets the drywall (how the partitions are built—with small returns in one or both directions, or just dead ended), attachment of the walls, whether to braced, drywall bulkheads above or a ceiling grid, etc. 09/28/18 IMAGES Postless Example 09/28/18 IMAGES With Post Examples 09/28/18 INTERPRETED SCOPE 09/28/18 PROJECT SPECIFICATIONS 09/28/18 PRICING SUMMARY Item Glass, Glass Doors, Frames Film Wood Doors ALUR Freight Installation Project Mgt Subtotal SalesTax Total 132 Lineal Feet of ALUR "With- post", Bronze Frames, Glass and Glass Pivot Doors per the plan provided 62,795.00$ 4,578.57$ -$ 6,541.00$ 9,900.00$ 990.00$ 84,804.57$ 7,886.83$ 92,691.40$ 132 Lineal Feet of ALUR "With- post", Bronze Frames, Glass and Wood Pivot DoorsGlass Sliding and Pivot Doors per the plan provided 61,146.00$ 3,178.57$ 11,912.50$ 6,473.00$ 9,900.00$ 990.00$ 93,600.07$ 8,704.81$ 102,304.88$ Assumptions *Any applicable sales taxes will be due. Estimated taxes shown at 9.3% for Aspen. *Budget assumes braced and blocked drywall headers and sidewalls adjacent to all glass fronts for attachment *All work to be performed during regular business hours (7:00AM – 3:30 PM M-F). See Terms and Conditions. *All Normal Delivery Conditions. See Terms and Conditions *Does not include prevailing wage unless otherwise specified. *Budget is based on Interpreted Scope above. If scope is other than interpreted, pricing will be amended accordingly. *Budget assumes elevator access to the space large enough to accommodate 9'-0" glass lites stacked on an A-frame dolly *Special handling or hoisting will be additional and quoted prior to work initiation. *Budget does not cost for installation travel. *50% deposit is required with order. 09/28/18 APPENDIX A SUSTAINABLE DESIGN MAI is committed to the environment with a determined mandate that extends throughout all facets of our operations. We recognize our environmental and social responsibility with our cost-efficient, energy saving line of products. Indoor Air Emission Standards Our products are GREENGUARD® certified, which means that they meet the stringent GREENGUARD® Emission Standards for indoor air quality. Therefore, our materials and finishes contain no toxic materials or release dangerous gases into the air, helping to improve productivity and prevent sick building syndrome. MAI also meets the requirements for maximum formaldehyde air emissions of both Occupational Safety and Health Administration (OSHA) and World Health Organization (WHO). Sustainable Product All MAI products including the steel frames are recyclable. And our panel fabrics are available in recyclable Eco Intelligence® polyester, a new standard for textile sustainability. We also partner with the leaders of green practices in the textile industry. The United States Environmental Protection Agency has accepted Guilford of Maine, one of our main fabric suppliers, into the National Environmental Achievement Track Program recognizing the company for modeling the way to environmental excellence. Life Cycle Cost Factors Determining the best value of furniture purchases calls for balancing the initial investment with lifetime costs associated with churn or moves, adds and changes (MACs). Current industry statistics report that the average turnover rate for most companies is 45% per year but can go as high as 200%! Our products are intelligently designed to allow you to make changes with speed, less disruptions and fewer parts than any other product on the market. And our quality construction keeps the system functional and beautiful. That equals cost savings not only in the short term but also exceptional value for the life of the product. Recycled Content* MAI adheres to a material conservation philosophy where materials are perpetually circulated in closed loops to maximize value without damaging ecosystems. In fact, our framing is constructed of recycled steel, and our patented, plug-and-play voice, data and power cabling systems are reusable for future changes. Our acoustical panels are filled with 100% post-consumer P.E.T., made from recycled plastic bottles eliminating all fiberglass content from our products. ** Here is a chart of the full contents of tackable acoustical panel: Material % By Weight Recycled Content End of Life Management Steel 79% 30% Post-Consumer Recycle Fabric 8% Up to 100% Post-Consumer Recycle where possible Polyester Wool (PET) 11% 100% Post-Consumer Recycle Misc. 2% N/A N/A Corrugated Packaging N/A 74% Average Recycle Shipping Sustainably MAI uses recyclable packaging materials, and offer bulk to divert excessive waste from ending up in landfills. We also implement carton-less techniques and minimal packaging on truckload orders. We have also reduced our carbon footprint by shipping completed orders directly to the job site and by-passing the installer’s warehouse to eliminate double and sometimes, even triple handling. In addition to protecting the environment from unnecessary packing materials, these packaging methods reduce the cost of de-trashing the office space and facilitate installation through less clutter. * MAI complies with the Federal Trade Commission part 260 Guide for the fair use of Environmental Marketing Claims. Product recyclability depends on local recycling program. ** American Conference of Governmental Industrial Hygienists (ACGIH) TLV-TWA, 1 fiber/cc, A3, confirmed animal carcinogen with unknown relevance to humans. 09/28/18 APPENDIX B ALUR LEED COMMERCIAL INTERIORS CONTRIBUTION POINT(S) LEED CATEGORY ENERGY & ATMOSPHERE 1-3 Pts EA Credit 1.1: Optimize Energy Performance—Lighting Power ALUR Glass Walls can use daylighting to reduce designed lighting loads and energy consumption. MATERIALS AND RESOURCES 1-2 Pts MR Credit 1.2: Building Reuse – Maintain Interior Nonstructural Components ALUR can be installed into an existing space without disturbing existing floor, wall & ceiling, and thus contributing to the credit requirement of maintaining at least 40& or 60% of the existing non- shell, non-structural components (e.g., walls, flooring and ceiling systems). 1-2 Pts MR Credit 2: Construction and Waste Management Waste from ALUR installations are all easily recyclable in many markets and can contribute to the minimum 50% or 70% of weight or volume of total construction or demolition debris. 1-2 Pts MR Credit 4: Recycled Content ALUR may contribute to this point as the aluminum framing, which represents an estimated 7% in weight of total product, contains approximately 20% post-consumer recycled content and 10% pre-consumer recycled content. 1-2 Pts MR Credit 5: Regional Materials Glass utilized in ALUR Glass Wall is manufactured locally in Colorado, and can contribute to meeting a minimum of 10% of the combined value of construction and Division 12 (furniture) materials and products extracted, harvested or recovered, as well as manufactured, within 500 miles of the project. INDOOR ENVIRONMENT QUALITY 1 Pt IEQ Credit 4.1: Low-Emitting Materials – Adhesives and Sealants The glazing tape on the acrylic joints used to join glass panels together is 100% solids and does not emit VOCs. 1 Pt IEQ Credit 4.2: Low-Emitting Materials – Paints and Coatings 1-2 Pts IEQ Credit 8.1: Daylight and Views – Daylight Using ALUR Glass Wall to create private offices and conference rooms help daylight reach occupants. 1Pt IEQ Credit 8.2: Daylight and Views – Views for Seated Spaces Using ALUR Glass Wall helps to achieve a direct line of sight to the outdoor environment via vision glazing between 30 inches and 90 inches above the finished floor for building occupants in 90% of regularly occupied areas. 09/28/18 APPENDIX C CONSTRUCTION SPECIFICATIONS ADA HANDLE SPECIFICATIONS 09/28/18 APPENDIX D PROJECT DRAWINGS 09/28/18 APPENDIX E OTHER DRAWINGS 09/28/18 09/28/18 ADA LOCKER SPECS 09/28/18 520 E COOPER UNIT C7 LOCKER SPECIFICATIONS AND ACCESSIBLE ACCESS HEIGHTS 09/28/18 09/28/18