HomeMy WebLinkAboutFile Documents.520 E Cooper Ave.0085.2018 (20).ACBK
ELEMENT ENVIRONMENTAL | Sherlock 100118 Cooper
189 County Road 135
Glenwood Springs, CO 81601
(970) 274-3139
Final Clearance Letter
For
520 E. Cooper C7
Aspen, CO 81611
October 1st, 2018
Prepared for
Sherlock Homes
Element Environmental Project Number
Sherlock 100118 Cooper
Prepared By:
Joshua Johnson
CDPHE Air Monitoring Specialist #18401
CDPHE Asbestos Consulting Firm #21640
10/02/2018
ELEMENT ENVIRONMENTAL | Sherlock 100118 Cooper
Element Environmental Date: 10/01/2018
189 County Rd. 135
Glenwood Springs, CO 81601
(970) 274-3139
josh@elementenconsults.com
Client: Sherlock Homes
Dear Mr. Sherlock,
I am pleased to offer you this report for work performed at the reference site.
On October 1st, 2018 Mr. Joshua Johnson with Element Environmental performed final clearances at 520 E.
Cooper C7, Aspen, CO. The final clearances consist of a visual inspection for dust and debris and ambient air
sampling. The clearance consisted of 1 containment. The removal was of the ACM drywall ceilings in Rooms 1,
20, 24 and the Mechanical Room. Any material that is remaining must be assumed to be ACM material until it
is tested.
Mr. Joshua Johnson CDPHE AMS #18401 performed a visual inspection. After the visual inspection was
complete air samples were taken of each of the work areas. Two samples were taken from the work area.
The air samples were analyzed by PCM (Phase Contrast Microscopy) per the NIOSH 7400 method. All samples
must below 0.01 f/cc in order to pass the air clearance. All samples were below the limit amount.
Per Colorado Reg 8 Part B guidelines. The work area is now clear for occupancy or normal work to
resume.
Any suspect asbestos containing materials (ACM) remaining should be assumed to contain asbestos unless
they are properly tested and analyzed by a CDPHE accredited inspector. All work performed MUST follow
appropriate EPA, CDPHE, OSHA, and local government guidelines to protect the employees, occupants, and the
environment.
_______________________________________________
Joshua Johnson Air Monitoring Specialist# 18401
10/02/2018
ELEMENT ENVIRONMENTAL | Sherlock 100118 Cooper
10/02/2018
ELEMENT ENVIRONMENTAL | Sherlock 100118 Cooper 10/02/2018
ELEMENT ENVIRONMENTAL | Sherlock 100118 Cooper
10/02/2018