Loading...
HomeMy WebLinkAboutFile Documents.520 E Durant Ave.0095.2017.ACBKOrdering Guide 5LED BO A R D & DRI V E RLUMINAIREWARRANTY YEAR CONTROLSENSORS © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 514.948.6272 Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information. 1 / 9 FILE NAME : B2SQS.LED.SPECJuly 14, 2017 axislighting.com SURFACE MOUNT - DIRECT Spotless Lens NOMINAL LUMEN OUTPUT INPUT WATTS*EFFICACY SHIELDING 1000 lm/ft 9.9 W/ft 97 lm/W L Please consult factory for custom lumen output and wattage. PERFORMANCE PER LINEAR FOOT AT 3500K Glo lensLouverSpotless Lens SO2 3/4” 3” 2 1/2” 1/4” B2SQDLED PRODUCT ID NOM. LUMENS/FT CRI COLOR TEMP.SHIELDING B2SQSLED Surface LED 400 400 lm/ft 80 80 CRI 27 2700 K SO spotless Lens 500 500 lm/ft 90 90 CRI 30 3000 K L louver (1) 750 750 lm/ft 35 3500 K 0.25G 0.25" Glo lens 1000 1000 lm/ft *40 4000 K Outputs between listed min and max are available. Consult factory for outputs outside of the listed range. * For louver only SurroundLite not available with direct (1) Available in 3' and 4' combinations; otherwise consult factory. MOUNTING/SUSPENSION BATTERY (OPTIONAL)OTHER (OPTIONAL)IC CONTROLS (OPTIONAL)CUSTOM (OPTIONAL) SB9 surface TB/TG 9/16 B#battery pack (integral)F fuse DS#daylight sensor C custom SB15 surface TB/TG 15/16 OS#occupancy sensor SBS surface screw slot t-bar DOS#daylight & occupancy sensor S surface drywall ceiling EN# Enlighted integral (7) SC surface solid ceiling ENR#Enlighted remote (7) Requires 120V or 277V Minimum 4ft; please consult factory Requires 120V or 277V (7) Please consult factory Specify quantity. Requires 8" blank See pages 5-6 for more details Please specify LENGTH MR (OPTIONAL)FINISH VOLTAGE DRIVER CIRCUITS 2 2’MR11LED(#)MR 11 LED AP aluminum paint 120 120 V DP dimming (0-10V) 1%1 1 circuit 3 3’W white 277 277 V D dimming (0-10V) 5% 347V standard (3)2 2 circuits 4 4’BLK black 347 347 V (2)LT Lutron (4)+E(#)emergency circuit (6) 5 5’C custom UNV universal BI bi-level dimming +NL(#)night light circuit (6) 6 6’O other (5)+GTD(#)generator transfer device (6) 8 8’+M MR 12 12’ S#system run Add 9” per lamp. Specify quantity. Separate circuits included Requires 120V or 277V (2) D dimming (0-10V) 5% standard (3) For 347 V only(4) Specify system (5) Please consult factory; see page 2 (6) Specify quantity Notes Type Project 1000 90 27 6 BLK 120 LT 1 0.25G DE - DURANT OFFICE © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 514.948.6272 Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information. 2 / 9 FILE NAME : B2SQS.LED.SPECJuly 14, 2017 axislighting.com SURFACE MOUNT - DIRECT LED SYSTEM CRI Minimum 80 or 90 color rendering index. CCT Choice of 2700K, 3000K, 3500K and 4000K color temperature with a great color consistency (within 3–step MacAdam ellipse). Both within fixture and fixture to fixture. LED life Minimum 50,000h with 85% of lumen maintenance in 250C ambient temperature, in compliance with IES LM-80 testing measurements. Thermal Management Aluminum housing acting as the heat sink to maximize life. Environment Dry and damp rated in operating ambient temperatures of 0-400C (32-104F). Louver LED Individual for LED cluster in each louver cell. BEAM2 SQUARE linear systems, with the use of a strong profile, allow for a nearly hair thin connection system of continuous runs. Lengths of 4', 8', 12' as well as custom lengths are available. Runs of BEAM2 SQUARE that are greater than 12' in length are designated as systems (S#). This means that the run is comprised of a combination of 4', 8' and/or 12' sections to be assembled on site using our joining system. For more information on systems and joining, please refer to the BEAM installation sheets available for download at www.axislighting.com. SYSTEM (S#) Axis Lighting will warrant defective LEDs, boards, and drivers for 5 years from date of purchase. Warranty is valid if luminaire is installed and used according to specifications. If defective, Axis will send replacement boards or drivers at no cost along with detailed replacement instructions and instructions on how to return defective components to Axis. WARRANTY CONSTRUCTION Housing Extruded aluminum (0.075'' nominal) Up to 70% recycled content End Cap Cast aluminum Interior Brackets Die formed sheet steel (20 gauge) Reflectors White powder coated sheet steel (22 gauge) Louvers Die formed semi-specular aluminum (22 gauge) Lenses Extruded acrylic (0.070'' nominal) SPECIFICATIONS ELECTRICAL Lutron driver L3D - Hi-Lume A-Series EcoSystem 3-Wire Control (1%)LDE1 - EcoSystem H-Series (1%)LDE5 - EcoSystem 5-Series (5%)LTE - Hi-Lume® A-series 2Wires Forward Phase (1%) Other drivers DALI - Digital Addressable Lighting InterfaceDMX - Digital MultiplexLV - line voltage - Advance Mark 10Xitanium SR - For wireless sensor Emergency Integral emergency battery pack or emergency circuit optional. Input Voltage 120V, 277V, 347V, UNV. Incorporating these components may have limitations or affect the length of the luminaire. Please contact factory for more details. OPTICS L LouverSO spotless lens 0.25G Glo lens SPOTLESS LENS Frosted acrylic snap-in micro lens. PARABOLIC LOUVERS Die formed semi-specular aluminum (22 gauge). GLO LENS 0.25" frosted acrylic drop lens. Patented design. © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 514.948.6272 Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information. 3 / 9 FILE NAME : B2SQS.LED.SPECJuly 14, 2017 axislighting.com SURFACE MOUNT - DIRECT TWIN BEAM2 SurroundLite luminaires feature InstaJoiner, a unique, patent-pending joining system developed by Axis offering fast, single-screw tightening. NOTE: Mount each system segment individually. Do not assemble system prior to mounting Allow a minimum of 6" between end of long runs and wall. InstaJoiner © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 514.948.6272 Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information. 4 / 9 FILE NAME : B2SQS.LED.SPECJuly 14, 2017 axislighting.com SURFACE MOUNT - DIRECT SECTION VIEWS 2 3/4” 3” 2 1/2” 1/4” 2 3/4” 2 1/2” 2 3/4” 2 1/2” L Louver SO Spotless lens 0.25G 0.25" Glo lens © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 514.948.6272 Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information. 5 / 9 FILE NAME : B2SQS.LED.SPECJuly 14, 2017 axislighting.com SURFACE MOUNT - DIRECT MOUNTING OPTIONS End to End Lamping:T5/T5HO LAMP BEAM2 SQUARE 4' (42 9/16" C.C.) BEAM2 SQUARE 8' (88 7/8" C.C.) BEAM2 SQUARE 12' (135 3/16" C.C.) T8 LAMP BEAM2 SQUARE 4' (44 1/4" C.C.) BEAM2 SQUARE 8' (92 1/4" C.C.) BEAM2 SQUARE 12' (138 1/4" C.C.) MOUNTING DETAILS SB SURFACE MOUNT T-BAR CEILING SC SURFACE MOUNT SOLID CEILING S SURFACE MOUNT DRYWALL CEILING OTHER MOUNTING OPTIONS BEAM2 SQUARE is also available with pendant and wall mounted options. Specification sheets and installation sheets for all mounting for BEAM luminaires are available for download at www.axislighting.com POWER FEED POWER FEED POWER FEED NON POWER FEED NON POWER FEED NON POWER FEED assembled T-bar clip threaded rodanchored tobuilding structure ceiling joist junction box crossbarpower cord junction box crossbarpower cord junction box crossbar threadednipple power cord Blank Extruded aluminum (0.075'' nominal) MR11 LED 1.4'' diameter Quantity For every 4' section, there may be up to a maximum of 4 x MR11 LED lamps. Spacing Each MR11 LED lamp is placed centered on a blank section 6'' in length. For a series of MR11's within a given section length, they will be spaced evenly on a longer blank section. The directed light of MR11 LED lamps are fixed downward. Custom spacing may be available on special request. MR11 LED LAMPS More options are available upon request. Please consult factory. Beam Angle 45 nominal degrees Input Watts 3W Nominal Lumens 50 lumens Efficacy 17 lumens per watt Color Rendering Index (CRI) 80 Life 25,000 hours at L70Correlated color temperature (CCT) 2700K 2 1/4" 2 " 3 5/8" Between sections Several in a long blank section At luminaire ends variable 6" 6" © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 514.948.6272 Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information. 6 / 9 FILE NAME : B2SQS.LED.SPECJuly 14, 2017 axislighting.com SURFACE MOUNT - DIRECT © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 514.948.6272 Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information. 7 / 9 FILE NAME : B2SQS.LED.SPECJuly 14, 2017 axislighting.com SURFACE MOUNT - DIRECT With Daylight sensors, maximum lamp output is reduced according to the available amount of natural light. By reducing maximum lamp output, energy consumption is reduced by up to 20 percent in a process known as “Daylight Harvesting”. DAYLIGHT HARVESTING (DS): EC-DIR-WH, FD-301 Luxsense, Micro Luxsense Shown with Luxsense * Incorporating IC controls may affect the length of the luminaire. Please contact factory for more details. When a room is vacated, occupancy sensors ensure the light will be turned off after a programmed delay as well as ensuring that light remains on while the room is occupied. OCCUPANCY (OS): Shown with FS-205 FS-205, FS-355, FS-155 - Line Voltage FS-505, FS-505C The integrated control systems offered are: INSTALLATION EXAMPLE Sensor location option controlsoption DAYLIGHT HARVESTING AND OCCUPANCY (DOS): INTEGRATED CONTROLS ENLIGHTED INTEGRAL (EN) / ENLIGHTED REMOTE (ENR): A combination of Daylight, Occupancy & Temperature autonomously control illumination levels, monitor occupancy and environmental conditions. Data is transmitted wirelessly to the Enlighted networked management system. Shown with Actilume DALI Actilume 1-10VActilume DALI ACTILUME, a combination of Daylight & Occupancy sensor from Philips, along with a 0-10V or DALI driver can be used in one form factor. BEAM2 SQUARE luminaires allow the use of integrated controls such as daylight sensors (DS), occupancy sensors (OS) and combination daylight/occupancy sensors (DOS). These options can be seamlessly integrated into our luminaires. The control system could be used to optimize the lighting of the space by reducing energy consumption through daylight harvesting and occupancy, thereby improving the overall interior environment and allowing for LEED credits. ● Consult factory for other options. CONTROLSENSORS © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 514.948.6272 Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information. 8 / 9 FILE NAME : B2SQS.LED.SPECJuly 14, 2017 axislighting.com SURFACE MOUNT - DIRECT SENSORS BRAND Model TYPE Daylight Sensor (DS) Lutron EC-DIR-WH Daylight, IR Wattstopper FD-301 Daylight Philips Luxsense, LR1220/00 Daylight Philips Micro Luxsense Daylight Wattstopper LS-102 Light Saver (Ambient light level) Occupancy Sensor (OS) Wattstopper FS-205v2 PIR Occupancy & Ambient light level Wattstopper FS-355 (need lenses)PIR Occupancy & Ambient light level Wattstopper FS-155 PIR Occupancy & Ambient light level Wattstopper FS-505 Ultrasonic Occupancy (Staircase) Wattstopper FS-505C Ultrasonic Occupancy (Open Area) Wattstopper FM-105 High Frequency Occupancy (Wet) Lutron TriPak Wireless LRF2-OCR2B-P-WH PIR Occupancy Lutron LOS-CDT Ultrasonic Occupancy + PIR Lutron LOS-CIR PIR Occupancy Daylight & Occupancy Sensors (DOS) Philips Actilume, LR11655 Daylight & PIR Occupancy Wattstopper FS-305 (need Lenses)PIR Occupancy Wattstopper FS-305 RC PIR Occupancy & Ambient light level Creston GLS Series Daylight and/or PIR Occupancy Echofl ex MOS Series Daylight and/or PIR Occupancy Enlighted sensor (EN, ENR) Enlighted integral / remote SU-3E-00 Daylight, Occupancy & Temperature INTEGRATED CONTROL OPTIONS © 2016 Axis Lighting Inc. 1.800.263.2947 [T] 514.948.6272 Product design and development is an ongoing process at Axis Lighting. We reserve the right to change specifications. Contact Axis for the latest product information. 9 / 9 FILE NAME : B2SQS.LED.SPECJuly 14, 2017 axislighting.com SURFACE MOUNT - DIRECT PHOTOMETRIC DATA LUMINANCE DATA (cd/m2) Horizontal Angles Vertical Angle 0 45 90 45 4597 15642 10171 55 949 2223 7334 65 219 521 807 75 110 208 312 85 77 154 212 1 2 90° 60° 120° 30°0° 180° 120°120° 60°60° 90°90° 30° 150° 0° 90°0 °3142 2356 1571 785 Lumen/ft: 1000 lm/ft Total Lumens: 3854 lm (for 4ft) Input Watts: 39.6 W Efficacy: 97 lm/W IES FILE: B2SQSLED-0-1000-80-35-L-4.IES TESTED ACCORDING TO IES LM-79-2008 80 CRI shown. To calculate watts and efficacy at 90 CRI, apply a multiplier of 0.8. Horizontal Angles Vertical Angle 0 22.5 45 67.5 90 0 2297 2297 2297 2297 2297 5 2356 2348 2337 2321 2312 15 2483 2504 2693 2915 2904 25 2322 2513 3107 3055 2851 35 1290 1752 2342 1633 1320 45 194 307 658 478 428 55 32 48 76 175 250 65 6 8 13 17 20 75 2 2 3 5 5 85 0 1 1 1 1 90 0 0 0 0 0 CANDELA DISTRIBUTION ZONAL LUMENS Lumens Zone 0 0-10 228 10-20 768 20-30 1260 30-40 1073 40-50 397 50-60 106 60-70 19 70-80 4 80-90 1 90 PHOTOMETRIC CURVE 1000 lm/ft