HomeMy WebLinkAboutFile Documents.905 Chatfield Rd.0111.2018 (28).ARBKDEW POINT CALCULATION JOB NAME: Silverstein JOB NUMBER: 17085.00 DATE: 4/19/18 CALCS BY: JAH DP @ DP @ DP @ DP @ DP @ 20% RH 25% RH 30% RH 35% RH 45% RH 30 33 37 41 48 -20 Indoor design temperature (IDT)70 90 R-value 0.17 10.00 0.77 49.00 0.63 0.56 0.61 61.74 1.80 67 41 YES Note: To minimize the potential for condensation problems, humidity levels within the home must be properly controlled and adjusted based on outdoor temperatures. Is TA warmer than the DPA? Inside air layer R-Total R-value at A A: point of condensation analysis 1/2" plywood 5/8" gypboard TA = IDT - (R-value at A)/(R-Total) * (Delta T) TA = Temperature at point A DPA = Dew point at point A (35% RH) 2" rigid insulation (R-5/in) 5/8" plywood 7.5" spray foam insulation (R-6.53/in) Outdoor design temperature (ODT) Delta T = IDT - ODT Layer Thermal Resistance of Proposed Roof Assembly Outside air layer 4/19/18 04/26/2018