HomeMy WebLinkAboutFile Documents.COACH RD.0079.2018 (16).ARBKAir System Sizing Summary for ADU Project Name: 18003-DBX 7 03/27/2018 Prepared by: RADER ENGINEERING INC.01:39PM Air System Information Air System Name ADU Equipment Class UNDEF Air System Type SZCAV Number of zones 1 Floor Area 833.0 ft² Location Eagle, Colorado Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.4 Tons Total coil load 28.4 MBH Sensible coil load 27.3 MBH Coil CFM at Sep 1400 1614 CFM Max block CFM 1614 CFM Sum of peak zone CFM 1614 CFM Sensible heat ratio 0.961 CFM/Ton 682.7 ft²/Ton 352.2 BTU/(hr·ft²)34.1 Water flow @ 10.0 °F rise 5.68 gpm Load occurs at Sep 1400 OA DB / WB 82.9 / 61.7 °F Entering DB / WB 73.1 / 58.1 °F Leaving DB / WB 52.2 / 50.8 °F Coil ADP 49.9 °F Bypass Factor 0.100 Resulting RH 45 % Design supply temp.50.0 °F Zone T-stat Check 1 of 1 OK Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil load 29.5 MBH Coil CFM at Des Htg 1614 CFM Max coil CFM 1614 CFM Water flow @ 20.0 °F drop 2.95 gpm Load occurs at Des Htg BTU/(hr·ft²)35.4 Ent. DB / Lvg DB 68.9 / 91.5 °F Humidifier Sizing Data Max steam flow at Des Htg 0.92 lb/hr Airflow Rate 1614 CFM Air mass flow 5437.68 lb/hr Moisture gain .00017 lb/lb Supply Fan Sizing Data Actual max CFM 1614 CFM Standard CFM 1208 CFM Actual max CFM/ft²1.94 CFM/ft² Fan motor BHP 0.33 BHP Fan motor kW 0.26 kW Fan static 0.75 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/ft²0.00 CFM/ft² CFM/person 0.00 CFM/person Hourly Analysis Program 5.11 Page 1 of 2 3/30/18 4/5/2018 Zone Sizing Summary for ADU Project Name: 18003-DBX 7 03/27/2018 Prepared by: RADER ENGINEERING INC.01:39PM Air System Information Air System Name ADU Equipment Class UNDEF Air System Type SZCAV Number of zones 1 Floor Area 833.0 ft² Location Eagle, Colorado Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Terminal Sizing Data Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft² Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) ADU 1614 1614 1.94 0.0 0.00 0.0 0.00 0 Zone Peak Sensible Loads Zone Zone Zone Cooling Time of Heating Floor Sensible Peak Sensible Load Area Zone Name (MBH)Cooling Load (MBH)(ft²) ADU 27.7 Sep 1500 30.8 833.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft²) Space CFM/ft² ADU A-10 Entry & Living 1 23.6 Sep 1500 1329 25.7 509.0 2.61 A-13 Storage 1 0.3 Jul 1700 19 0.4 34.0 0.55 A-14 Hall 1 1.2 Jul 1500 69 0.3 40.0 1.72 A-15 Bedroom 1 1.8 Jul 1700 104 2.5 154.0 0.68 A-16 WIC 1 0.4 Jul 1500 39 0.9 30.0 1.29 A-17 Bath 1 1.0 Jul 1500 55 1.0 66.0 0.83 Hourly Analysis Program 5.11 Page 2 of 2 4/5/2018