HomeMy WebLinkAboutFile Documents.805 Roaring Fork Rd.0019.2018 (6).ARBK 1
HealthSafe Inspections Inc
390 Apple Drive
Basalt CO 81621
970-920-2100
Jim Baker
CDPHE Asbestos Building Inspector Certification #13437
CDPHE Lead-Based Paint Inspector Certification #23607
ASBESTOS REPORT
DATE:
06/30/2017
CLIENT:
Charlie Moss
c/o Sarah Oates
533 E Hopkins Ave, Suite 201
Aspen CO 81611
PROJECT PROPERTY ADDRESS:
805 Roaring Fork Road, Aspen, Colorado 81611
01/22/2018
2
COLORADO ASBESTOS REGULATIONS SUMMARY:
Colorado State Regulation 8 requires a State-certified Asbestos Building Inspector to
inspect and sample for suspect asbestos containing materials (ACM) or suspect asbestos
containing building materials (ACBM) prior to the disturbance, removal or demolition.
In residential buildings of four or fewer units if more than 32 square feet of any surface
coverage (e.g., gypsum wallboard or drywall and associated applied surfacing
materials/textures, acoustic sprays, joint compounds, plaster, etc.), 50 feet of asbestos
covered or asbestos insulated pipe or any material which would fill a 55-gallon drum—if
these materials are going to be disturbed or removed—an asbestos inspection is required
by a state certified asbestos building inspector. For buildings with more than four
residential units (considered public), including commercial, public (including public
access areas to a residential building), civic or industrial buildings, if more than 160
square feet of surfacing materials, 260 linear feet or more than 35 cubic feet of suspect
ACM/ACBM is going to be disturbed, an asbestos inspection is required under NESHAP.
County or City regulations may be more stringent. The regulations require an absolute
01/22/2018
3
minimum of 3 samples (EPA suggests 9) per homogenous suspect surfacing and TSI
materials and an absolute minimum of 1 sample of homogenous miscellaneous materials
or any number of “samples sufficient to determine whether a material is ACM”
(Reg8.IV.D.3). More samples are required based on surface area or volume. For the
contractor to proceed with disturbance, demolition, restoration or remodel/renovation the
suspect materials have to be sampled and analyzed by a NVLAP accredited laboratory by
polarized light microscopy (PLM) methods. OSHA compliance is required for all
employers/employees no matter the quantity of asbestos present.
CLIENT BACKGROUND:
Charlie Moss through Sarah Oates hired HealthSafe Inspections, Inc. (hereinafter,
HealthSafe) to perform an asbestos building inspection, bulk sampling and report for the
single-family residence interior only. The Client, Charlie Moss, is under contract to
purchase the above addressed property and requested that an asbestos inspection be
performed for the interior suspect materials. This report is limited to the house and garage
interiors.
VISUAL INSPECTION & LABORATORY FINDINGS:
An inspection was conducted by Jim Baker of HealthSafe on Tuesday evening, June 27,
2017 with Tommy Nims, the seller’s real estate representative, present during the
inspection. Suspect ACM/ACBM (drywall materials and sheet vinyl flooring only)
were identified and sampled. Those materials are the following:
1. A sheet vinyl flooring material in the storage room and garage laundry room, a
homogeneous miscellaneous material requiring at least one sample [sample 1].
The PLM analytical estimated results: NONE DETECTED.
2. A homogeneous taped and joint compounded drywall system (classified as a
miscellaneous material as a complete integral system) [samples 2-3]. These
composite layered taped and joint compounded drywall materials are on ceilings
and walls of the house interior two floors with a surfacing material/texture known
as “flat-finish“. The estimated surface area is more than 5,000 sf, requiring a
minimum of at least two composite core samples of all drywall layers (“…number
of samples sufficient to determine” …if asbestos is present or not). One was
taken from the ground floor inside a closet and the second one from a master
closet on the second floor. The PLM analytical estimated results: NONE
DETECTED.
3. A homogeneous trowel-applied flat-finish surfacing material/texture [samples 4-
10]. This surfacing material/texture is on ceilings and walls of the two floors of
the house interior and some garage walls. The estimated surface area is more than
5,000 sf, requiring a minimum of at least seven surfacing/texture material
samples. The PLM analytical estimated results: NONE DETECTED.
4. A homogeneous taped and joint compounded drywall system (classified as a
miscellaneous material as a complete integral system) [sample 11]; these
composite layered taped and joint compounded drywall materials are in the
01/22/2018
4
garage mechanical room and ceiling with a surfacing material/texture known as
“knock-down“ in the ceiling of the garage and laundry room. The estimated
surface area is more than 32 sf, but less than 1,000 sf, requiring a minimum of at
least a single composite core sample of all drywall layers (“…number of samples
sufficient to determine” …if asbestos is present or not). The PLM analytical
estimated results: NONE DETECTED.
5. A homogeneous spray-applied then troweled surfacing material/texture (“knock-
down”) [samples 12-14]. This surfacing material/texture is on the garage ceiling
and garage laundry room. The estimated surface area is more than 32 sf, but less
than 1,000 sf, requiring a minimum of at least three surfacing/texture material
samples. The PLM analytical estimated results: NONE DETECTED.
A total of 14 suspect homogeneous ACM/ACBM bulk samples were collected from the
interior spaces of the house and garage and 14 samples were analyzed. The bulk samples
were analyzed by PLM by a NVLAP accredited laboratory in accordance with Colorado
State Regulation 8 for the presence of asbestos mineral fibers. There is NO asbestos in
all 14 samples analyzed.
See supporting Hayes Microbial Consulting, Inc. data report #17017685.
HEALTHSAFE CONCLUSIONS:
There is NO asbestos in any of the interior suspect building materials of the house and
garage. If changes are slated to be made of the house and garage interiors NO asbestos
abatement will be required. All interior building materials that may need to be removed
or disturbed can be dealt with without the concerns for asbestos fibers. All building
waste and debris can be disposed of in any landfill which accepts normal, non-hazardous
building waste.
Sincerely Submitted,
Jim Baker
01/22/2018
HMC #17017685
contact@hayesmicrobial.com
http://hayesmicrobial.com/
Analysis Report prepared for
HealthSafe Inspections
390 Apple Drive
Basalt, CO. 81621 USA
Phone: 970-920-2100
Job Name: Moss c/o Sarah Oates
805 Roaring Fork Rd
Aspen CO 81611
Date Sampled: 06-27-2017
Date Analyzed: 06-30-2017
Report Date: 06-30-2017
EPA Laboratory ID# VA01419
NVLAP Lab Code: 500096-0 Asbestos License: 300435 License: #PH-0198
Page 1 of 5
01/22/2018
HMC #17017685
HealthSafe Inspections
390 Apple Drive
Basalt, CO 81621 USA
June 30, 2017
Client Job Number:
Client Job Name:Moss c/o Sarah Oates
805 Roaring Fork Rd
Aspen CO 81611
Dear HealthSafe Inspections,
We would like to thank you for trusting Hayes Microbial for your analytical needs. On June 29, 2017 we received 14 samples by FedEx for the job
referenced above. 14 samples were received in good condition.
The results in this analysis pertain only to this job, collected on the stated date and should not be used in the interpretation of any other job. This report
may not be duplicated, except in full, without the written consent of Hayes Microbial Consulting, LLC.
This laboratory bears no responsibility for sample collection activities, analytical method limitations, or your use of the test results. Interpretation and
use of test results are your responsibility. Any reference to health effects or interpretation of mold levels is strictly the opinion of Hayes Microbial
Consulting. In no event, shall Hayes Microbial Consulting or any of its employees be liable for lost profits or any special, incidental or consequential
damages arising out of your use of the test results.
Steve Hayes, BSMT(ASCP)
Laboratory Director
Hayes Microbial Consulting, LLC
Page 2 of 5
01/22/2018
HMC #17017685
EPA 600/R-93, M-4/82-020 (PLM)HealthSafe Inspections
390 Apple Drive
Basalt, CO 81621 USA
Phone: 970-920-2100
Job Number:
Collected by:
Email:
Jim Baker
healthsafeinspections@gmail.com
Job Name:Moss c/o Sarah Oates
805 Roaring Fork Rd
Aspen CO 81611
Date Collected:
Date Received:
Date Reported:
06/27/2017
06/29/2017
06/30/2017
#Sample Name Description Asbestos Fibers Other Fibers Non- Fibers
1 1 805-STOR-V Vinyl / Gray
(None Detected)
(None Detected)
100 %
2 2 805-FLT-C/W-J-1 Drywall / Gray
(None Detected)
15 % Cellulose fibers
85 %
Layer 2 805-FLT-C/W-J-1 Joint Compound / White
(None Detected)
(None Detected)
100 %
3 3 805-FLT-C/W-J-2 Drywall / White
(None Detected)
12 % Cellulose fibers
88 %
Layer 2 805-FLT-C/W-J-2 Joint Compound / White
(None Detected)
(None Detected)
100 %
4 4 805-FLT-C/W-T-1 Texture / White
(None Detected)
(None Detected)
100 %
5 5 805-FLT-C/W-T-2 Texture / White
(None Detected)
(None Detected)
100 %
6 6 805-FLT-C/W-T-3 Texture / White
(None Detected)
(None Detected)
100 %
7 7 805-FLT-C/W-T-4 Texture / White
(None Detected)
12 % Cellulose fibers
88 %
8 8 805-FLT-C/W-T-5 Texture / White
(None Detected)
(None Detected)
100 %
9 9 805-FLT-C/W-T-6 Texture / White
(None Detected)
(None Detected)
100 %
Signature: Date:06/30/2017 Reviewed by: Date:06/30/2017
Page 3 of 5
01/22/2018
HMC #17017685
EPA 600/R-93, M-4/82-020 (PLM)HealthSafe Inspections
390 Apple Drive
Basalt, CO 81621 USA
Phone: 970-920-2100
Job Number:
Collected by:
Email:
Jim Baker
healthsafeinspections@gmail.com
Job Name:Moss c/o Sarah Oates
805 Roaring Fork Rd
Aspen CO 81611
Date Collected:
Date Received:
Date Reported:
06/27/2017
06/29/2017
06/30/2017
#Sample Name Description Asbestos Fibers Other Fibers Non- Fibers
10 10 805-FLT-C/W-T-7 Texture / White
(None Detected)
(None Detected)
100 %
11 11 GAR-MECH-J Joint Compound / White
(None Detected)
8 % Cellulose fibers
92 %
12 12 KD-GAR-CLG-T-1 Texture / White
(None Detected)
(None Detected)
100 %
13 13 KD-GAR-CLG-T-2 Texture / White
(None Detected)
(None Detected)
100 %
14 14 KD-GAR-CLG-T-3 Texture / White
(None Detected)
(None Detected)
100 %
Signature: Date:06/30/2017 Reviewed by: Date:06/30/2017
Page 4 of 5
01/22/2018
HMC #17017685
Asbestos - Additional InformationHealthSafe Inspections
390 Apple Drive
Basalt, CO 81621 USA
Phone: 970-920-2100
All samples were received in acceptable condition unless otherwise noted on the report. The Report must not be used by the client to claim product certification, approval, or
endorsement by: AIHA, NIST, NVLAP NY ELAP, or any agency. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with
estimating percentages by polarized light microscopy. Measurement uncertainty data can be provided when requested. None detected: Below the detected reporting limit of 1% unless
point counting is performed, then the detected, reporting limit is .25%. Per NY ELAP198.6 (NOB) TEM is the only reliable method to declare an NOB material as Non-Asbestos
Containing. Hayes Microbial Consulting reserves the right to dispose of all samples after a period of 60 days in compliance with state and federal guidelines.
Signature: Date:06/30/2017 Reviewed by: Date:06/30/2017
Page 5 of 5
01/22/2018
01/22/2018
01/22/2018