HomeMy WebLinkAboutFile Documents.805 Roaring Fork Rd.0019.2018 (25).ARBK95% AFUE Efficiency Lochinvar.com HIGH EFFICIENCY CONDENSING BOILERS REMOTE CONNECT CAPABLE OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER 7 MODELS: 55,000 – 399,999 BTU/HR FIRING RATE MODULATION TO 5:1 LESS THAN 20 ppm NOx DIRECT VENT FLEXIBILITY TO 100 FEET 01/22/2018 The KNIGHT® Wall Mount, engineered with Lochinvar’s exclusive SMART SYSTEM™ control and an array of other innovative features is far ahead of any heating boiler in its class. It promises and delivers ultimate ease of installation and maintenance. With up to 99% efficiency, low-NOx emissions and a fully modulating burner, it is the best ”green choice” for today’s environmentally focused market. Seven modulating/condensing stainless steel KNIGHT Wall Mount boilers are available with 55,000–399,999 Btu/hr inputs in a space- saving wall-mounted design. All are equipped for direct-vent installation with air intake and exhaust runs up to 100 feet using PVC, CPVC, Polypropylene or AL29-4C vent materials. This range of choices is ideal for residential or light-duty applications such as small hotels, schools and office buildings. For higher-demand applications, up to eight KNIGHT Wall Mount units can be installed utilizing the built-in cascading sequencer to deliver up to 3.2 million Btu/hr heating capacity. The KNIGHT Wall Mount Boiler reflects Lochinvar’s constant commitment to providing all the options you need to serve every application. Advanced Negative Regulation Technology KNIGHT safely and reliably operates with supply gas pressure as low as 4 inches water column. Negative Regulation (Neg/Reg) technology automatically adjusts fan speed to ensure the correct volume and mix of fuel and air throughout the firing range. Fire Tube Design This fully welded ASME Certified stainless steel heat exchanger uses oval shaped tubes to pass heat from the products of combustion into the water stored in the vessel. To facilitate heat transfer the tubes are manufactured with dimples to slow the flue products and extract available latent energy. With a fire tube design the flue products are inside tapered passage ways and the water is passed through the vessel. Since the flue products pass through tubes and the water is circulated through a larger diameter vessel a fire tube design allows for minimal head pressure loss through the boiler which allows the boiler to be installed easily into various hydronic applications. Water-Backed Combustion Chamber An outstanding feature of the fire tube design is a water backed combustion chamber. By having the combustion chamber surrounded by water the Knight Wall Mount has more heating surface area. This larger heating surface area allows for efficiencies up to 99%. Fully Modulating Burner The SMART SYSTEM allows fully modulating combustion with 5:1 turndown. The burner can fire as low as 20% of maximum input and modulates the firing rate up to 100% as demand increases. The burner is a single stainless steel assembly covered with woven steel mesh and fires in a 360° pattern along the entire length of the burner. This allows the compact KNIGHT to exceed the modulation capacities of units with larger multiple burners. The Smartest Choice for The Smartest Choice for Condensing Boiler PerformanceCondensing Boiler Performance KNIGHT offers 5 venting options and tremendous flexibility for placement of units within the building, because it permits direct-vent air intake and exhaust runs up to 100 equivalent feet using either PVC, CPVC, Polypropylene or AL29-4C stainless steel vent pipe. Direct Venting up to 100 Feet Direct Vent Vertical Concentric Direct Vent Vertical*Direct Vent Sidewall Concentric Direct Vent Sidewall*Vertical w/Sidewall Air *Optional Vent Kit Sold Separately 5 Flexible Venting Options 01/22/2018 • multi-color graphic lcd display • navigation dial • usb port • ability to control up to three different setpoint temperatures • compatibility with copper-fin ii non-condensing boiler to create a front-end loading system • boilers with different inputs can be cascaded together to maximize boiler plant turndown • modbus capability (optional) • dhw modulation limiting • dhw night setback* • 0-10 v boiler rate output • 0-10 v signal to control variable speed boiler pump* • 0-10 v system pump signal input* • heat demand from 0-10v input • installer can program name and number into the boiler • installer adjustable freeze protection parameters • separately adjustable sh/dhw switching times* • installer access to bms and ramp delay settings *Exclusive to Lochinvar Smart System Refined Design Puts More Control and Information at your Fingertips Advannced featuurrees iincclude:: Lead-Lag Cascade The “lead” boiler modulates with demand to capacity. As demand increases, additional boilers fire and modulate to capacity. This continues, with additional boilers firing and modulating to capacity until all units are operating. Every 24 hours, the SMART SYSTEM automatically shifts the lead boiler role to the next in the sequence, distributing lead-lag runtimes equally. Efficiency Optimized Cascade This feature optimizes the modulation capabilities of the Boiler Plant while evenly distributing run time across all cascaded boilers. Every 24 hours the SMART SYSTEM automatically shifts the 1st boiler on role to the next in the sequence, distributing run time equally. SMART SYSTEM Cascade allows 2 - 8 boilers to be sequenced. New Selectable Cascade Options When muultiiple KKNIGHT boileers aaree iinstalledd together,r,tthee SSMARTT SSYYSYSSTEM built--inn sseeqquencer can be setet foor ““Leadad-Lag” cascaade oor ““Efficienccy Optimizzedd”caascadde ooppeeratioon. At-a-Glance Color Coding yellow screen Maintenance due - shows the installer’s name and number on the display. red screen Lockout mode. blue screen Normal system operation. The CON·X·US mobile communication platform allows SMART SYSTEM to go where no other boiler has gone before.† CON·X·US provides the ability to monitor and manage multiple Knight heating boilers without ever stepping into the mechanical rooms. CON·X·US will send alerts via text or e-mail notifying of changes in system status, and anytime, from anywhere, a user can check system status and re-program any boiler function. Once downloaded, the free CON·X·US mobile application allows for remote access to all SMART SYSTEM functions using an Internet-capable device. †CON·X·US control board sold separately. cation allows for remo sing an Internet-capable dev old separa er stepping into alerts via text or e-mail notify and anytime, from anywhere, a user c e-program any boiler function. Once downlo obile application allows for remote access mmunication plattion pla ther boiler has gone before.gone beforeas gone before.†† and manage mulprovides the abi g boilers without ever stepping into the mechanical roo X·US will send alerts via text or e-mail notifying of change status, and anytime, from anywhere, a user can chec 01/22/2018 WHN-04 (Replaces WHN-03 11/14) PDP-7.5M-5/15-Printed in U.S.A. Smart System™ Features > SMART SYSTEM Digital Operating Control Multi-Color Graphic LCD Display with Navigation Dial and Soft Keys > Three Boiler Setpoint Temperature Inputs Plus Domestic Hot Water Prioritization > Built-in Cascading Sequencer for up to 8 Boilers Multiple Size Boiler Cascade Lead Lag Efficiency Optimization Front End Loading Capability with Copper Fin II > Outdoor Reset Control with Outdoor Air Sensor Programmable for Three Reset Temperature Inputs > Programmable System Efficiency Optimizers Night Setback DHW Night Setback* Anti-Cycling Outdoor Air Reset Curve Ramp Delay Boost Temperature & Time > Three Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable Speed Pump Control* Domestic Hot Water Pump > Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the Smart System DHW Modulation Limiting Separately Adjustable Space Heat/DHW Switching Times* > Building Management System Integration 0-10 VDC Input to Control Modulation or Set Point 0-10 VDC Modulation Rate Output 0-10 VDC Input to Enable/Disable call for heat > Access to BMS Settings through Graphic LCD Display > High-Voltage Terminal Strip 120 VAC / 60 Hertz / 1 Phase Power Supply Three Sets of Pump Contacts > Low Voltage Terminal Strip 24 VAC Device Relay Proving Switch Contacts Flow Switch Contacts Alarm on Any Failure Contacts Runtime Contacts DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10 VDC BMS External Control Contact 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Variable Speed System Pump Signal Input* 0-10 VDC Signal to Control Variable Speed Boiler Pump* Modbus Contacts > Time Clock > Data Logging Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts > Maintenance Reminder Custom Maintenance Reminder with Contractor Contact Information Installer Ability to De-activate Service Reminder > Low-Water Flow Safety Control & Indication > Password Security > Customizable Freeze Protection Parameters Standard Features > ENERGY STAR Most Efficient Recognition§ > 95% DOE AFUE Efficiency§ > Modulating Burner with 5:1 Turndown Direct-Spark Ignition Low-NOx Operation Field Convertible from Natural to LP Gas > ASME Stainless Steel Heat Exchanger 30 psi ASME Relief Valve > Vertical & Horizontal Direct-Vent PVC, CPVC, Polypropylene or SS Venting up to 100 feet > Smart System Control > Condensate Trap > Other Features Automatic Reset High Limit Adjustable High Limit w/Manual Reset Boiler Circulating Pump Wall-Mount Bracket Zero Clearances to Combustible Materials 12-Year Limited Warranty (See Warranty for Details) 2-Year Parts Warranty Optional Equipment CON·X·US Remote Connectivity Modbus Communication Flow Switch Low-Water Cutoff w/Manual Reset & Test Alarm Bell Concentric Vent Kit SMART SYSTEM PC Software Condensate Neutralization Kit BMS Gateway to LON or BacNet Multi-Temperature Loop Control Sidewall Vent Termination Floor Stand Wireless Outdoor Sensor Firing Codes > M9 Standard Construction > M7 California Code * Exclusive feature, available only from Lochinvar § WHN 55-285 only Input Heating Model Max. Min. *AFUE Capacity NetNumber MBH MBH % MBH MBH WHN055 55 11 95.0 51 44 WHN085 85 17 95.0 79 69 WHN110 110 22 95.0 102 89 WHN155 155 31 95.0 144 125 WHN199 199.9 40 95.0 185 161 WHN285 285 57 95.0 264 229 WHN399 399 80 94.4 377 328 A B C D E F G H I J K L M N O Gas Water Air Vent Shipping Conn. Conn. Inlet Size Wt. (lbs.) 33-1/4” 18-1/2” 16” 11-3/4” 10-1/2” 6-1/2” 4” 1-1/2” 3” 14-1/2” 5-3/4” 4” 3” 16-1/4” 5” 1/2” 1” 2” 2” 139 33-1/4” 18-1/2” 16” 11-3/4” 10-1/2” 6-1/2” 4” 1-1/2” 3” 14-1/2” 5-3/4” 4” 3” 16-1/4” 5” 1/2” 1” 2” 2” 142 33-1/4” 18-1/2” 19” 14-1/2” 10-3/4” 7-3/4” 7-3/4” 2-1/4” 10” 15-1/2” 5” 3-1/4” 3” 16-1/2” 2-3/4” 1/2” 1” 3” 3” 159 33-1/4” 18-1/2” 19” 14-1/2” 10-3/4” 7-3/4” 7-3/4” 2-1/4” 10” 15-1/2” 5” 3-1/4” 3” 16-1/2” 2-3/4” 1/2” 1” 3” 3” 166 33-1/4” 18-1/2” 19” 14-1/2” 11-3/4” 8” 8” 1-1/4” 10” 16-3/4” 4-3/4” 3-1/4” 2-3/4” 16-1/2” 3” 1/2” 1-1/4” 3” 3” 175 33-1/4” 18-1/2” 19” 14-1/2” 11-3/4” 8” 8” 1-1/4” 10” 16-3/4” 4-3/4” 3-1/4” 2-3/4” 16-1/2” 3” 1/2” 1-1/4” 3” 3” 184 35-1/2” 25” 21-3/4” 17-1/2” 12-1/2” 9-1/4” 9-1/2” 2-1/4” 13-1/4” 21-1/2” 9” 4-3/4” 4” 22-1/2” 3-3/4” 3/4” 1-1/2” 4” 4” 213 Notes: Indoor installation only. All information subject to change. Change "N" to "L" for LP gas models. *WHN399 value is Thermal Efficiency Knight Heating Boiler Dimensions and Specifications Knight® ® Wall-Mount Boiler Dimensions and Specifications Patent Pending Top Right Bottom Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com 55, 85: 3" FLUE FOR 100' 285: 3" FLUE FOR 50', 4" FOR 100' 01/22/2018 Product Data 24AHA4Performancet Series Air Conditionerwith Puronr Refrigerant1 --- 1/2 to 5 Nominal Tons Carrier air conditioners with Puron r refrigerant provide a collection of features unmatched by any other family of equipment. The 24AHA4 has been designed utilizing Carrier’s Puron refrigerant. This environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. NOTE:Ratings contained in this document are subject tochange at any time. Always refer to the AHRI directory(www.ahridirectory.org) for the most up--to--date ratingsinformation. INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S 14 SEER/11.7 -- 12.2 EER (Based on tested combinations) Sound S Levels as low as 66 dBA Design Features S Small footprint S WeatherArmort cabinet All steel cabinet construction Mesh coil guard Reliability, Quality and Toughness S Scroll compressor S Factory--supplied filter drier S High pressure switch S Low pressure switch S Accumulator S Line lengths up to 250’ (76.2 m) S Low ambient operation (down to --20_F/--28.9_C with low ambient accessories) 01/22/2018 2 MODEL NUMBER NOMENCLATURE 12 345678 N 91011 12 13 NN A A A/N N N A/N A/N A/N N N 24 AHA418 A00 3 0 Product Series Product Family Product Type Major Series SEER Cooling Capacity Variations Open Open Voltage Minor Series 24=AC A = AC H = Horizontal Discharge 4=14 SEER A=Standard 0=Not Defined 0=Not Defined 3=208/230---1 5=208/230---3 6=460/3 0, 1, 2... Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. PHYSICAL DATA UNIT SIZE --- SERIES 18---30 24---30 30---30 36---30, 50, 60 48---30, 50, 60 60---30, 50, 60 COMPRESSOR TYPE Scroll REFRIGERANT Puron(R---410A) Charge lb (kg)6.40 (2.90)6.50 (2.95)8.60 (3.90)8.90 (4.04)9.00 (4.08)10.60 (4.81) COND FAN Propeller Type, Direct Drive Air Discharge Horizontal Air Qty (CFM)1285 1285 1900 2615 2615 2785 Motor HP 1/12 1/12 1/10 1/4 1/4 1/4 Motor RPM 800 800 800 800 800 800 COND COIL Face Area (Sq ft)7.3 7.3 12.1 12.1 12.1 14.1 Fins per In.20 20 20 20 20 20 Rows 2 2 2 2 2 2 Circuits 3 3 3 3 3 4 VALVECONNECT.(In.ID) Vapor 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (In. OD) Rated Vapor*5/8 3/4 3/4 7/8 7/8 11/8 Max Liquid Line{3/8 * Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.Note: See unit Installation Instruction for proper installation. {See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. 01/22/2018 3 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths {for Cooling Only Systems with Puronr Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths : Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Size Liquid Line Connection Liquid Line Diam. w/ TXV AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit BELOW Indoor Vertical Separation ft (m) 0 --- 5(0---1.5)6 --- 10(1.8---3.0)11---20(3.4---6.1)21---30(6.4---9.1)31---40(9.4---12.2)41---50(12.5---15.2)51---60(15.5---18.3)61---70(18.6---21.3)71---80(21.6---24.4) 018 AC with Puron 3/8 1/4 150 150 125 100 100 75 --- ------ ------ --- 5/16 250*250*250*250*250*250*250*225*150 3/8 250*250*250*250*250*250*250*250*250* 024 AC with Puron 3/8 1/4 75 75 75 50 50 --- ------ ------ ------ --- 5/16 250*250*250*250*250*225*175 125 100 3/8 250*250*250*250*250*250*250*250*250* 030 AC with Puron 3/8 1/4 30 --- ------ ------ ------ ------ ------ ------ ------ --- 5/16 175 225*200 175 125 100 75 --- ------ --- 3/8 250*250*250*250*250*250*250*250*250* 036 AC with Puron 3/8 5/16 175 150 150 100 100 100 75 --- ------ --- 3//8 250*250*250*250*250*250*250*250*250* 048 AC with Puron 3/8 3/8 250*250*250*250*250*250*230 160 --- --- 060 AC with Puron 3/8 3/8 250*250*250*225*190 150 110 --- ------ --- * Maximum actual length not to exceed 200 ft (61 m) {Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. --- --- = o uts id e acce p tab le rang e Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Size Liquid Line Connection Liquid Line Diam. w/ TXV AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit ABOVE Indoor Vertical Separation ft (m) 25 (7.6) 26---50 (7.9---15.2) 51---75 (15.5---22.9) 76---100 (23.2---30.5) 101---125 (30.8---38.1) 126---150 (38.4---45.7) 151---175 (46.0---53.3) 176---200 (53.6---61.0) 018 AC with Puron 3/8 1/4 175 250*250*250*250*250*250*250* 5/16 250*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 024 AC with Puron 3/8 1/4 100 125 175 200 225*250*250*250* 5/16 250*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 030 AC with Puron 3/8 1/4 30 --- ------ ------ ------ ------ ------ ------ --- 5/16 250*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 036 AC with Puron 3/8 5/16 225*250*250*250*250*250*250*250* 3/8 250*250*250*250*250*250*250*250* 048 AC with Puron 3/8 3/8 250*250*250*250*250*250*250*250* 060 AC with Puron 3/8 3/8 250*250*250*250*250*250*250*250* * Maximum actual length not to exceed 200 ft (61 m) {Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. --- --- = o uts id e acce p tab le rang e 01/22/2018 4 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft (g/m) 3/8 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 1/4 0.27 (7.98) Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz (266.16 g). When using other length or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment Example 1:System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2:System has 45 ft of existing 5/16” liquid line. What is the charge adjustment? Formula: (.40 oz/ft. x 45ft) – (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the chart below shows when an application is considered Long Line. AC WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 No accessories needed within allowed lengths No accessories needed within allowed lengths 175 (53.3) 5/16 120 (36.6)50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 80 (24.4)35 (10.7) vertical or 80 24.4) total 80 (24.4) Note:SeeLongLineGuidelinefordetails VAPOR LINE SIZING AND COOLING CAPACITY LOSS LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft. (24.38 m) or when there is more than 20 ft. (6.09 m) vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is up to 250 ft. (76.2 m). The maximum vertical separation is 200 ft. (60.96 m) when outdoor unit is above indoor unit, and up to 80 ft. (24.38 m) when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Longline Application Guideline for required piping and system modifications. Also, refer to the table below for the vapor tube diameters based on the total length to minimize the cooling capacity loss. Vapor Line Sizing and Cooling Capacity Losses — Puronr Refrigerant 1--Stage Air Conditioner Applications Unit Nominal Size (Btuh) Maximum Liquid Line Diameters (In. OD) Vapor Line Diameters (In. OD) Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) 26---50 (7.9---15.2) 51---80 (15.5---24.4) 81---100 (24.7---30.5) 101---125 (30.8---38.1) 126---150 (38.4---45.7) 151---175 (46.0---53.3) 176---200 (53.6---61.0) 201---225 (61.3---68.6) 226---250 (68.9---76.2) 018 1Stage AC with Puron 3/8 1/2 1 2 3 5 6 7 8 9 11 5/8 0 1 1 1 2 2 2 3 3 3/4 0 0 0 0 1 1 1 1 1 024 1Stage AC with Puron 3/8 5/8 0 1 2 2 3 3 4 5 5 3/4 0 0 1 1 1 1 1 2 2 7/8 0 0 0 0 0 1 1 1 1 030 1Stage AC with Puron 3/8 5/8 1 2 3 3 4 5 6 7 8 3/4 0 0 1 1 1 2 2 2 3 7/8 0 0 0 0 1 1 1 1 1 036 1Stage AC with Puron 3/8 5/8 1 2 4 5 6 8 9 10 12 3/4 0 1 1 2 2 3 3 4 4 7/8 0 0 0 1 1 1 1 2 2 048 1Stage AC with Puron 3/8 3/4 0 1 2 3 4 5 5 6 7 7/8 0 0 1 1 2 2 2 3 3 11/8 0 0 0 0 0 0 0 1 1 060 1Stage AC with Puron 3/8 3/4 1 2 4 5 6 7 9 10 11 7/8 0 1 2 2 3 4 4 5 5 11/8 0 0 0 1 1 1 1 1 1 Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. 01/22/2018 5 ACCESSORIES KIT NUMBER KIT NAME Unit Size (Voltage/Series) 018 (30) 024 (30) 030 (30) 036 (30) 036 (50) 036 (60) 048 (30) 048 (50) 048 (60) 060 (30) 060 (50) 060 (60) KAACH1401AAA Crankcase Heater X X X X X KAACH1201AAA Crankcase Heater X X X X KAACH1501AAA Crankcase Heater X KAACH1901AAA Crankcase Heater X X KAAFT0101AAA Evaporator Freeze Stat X X X X X X X X X X X X KAATD0101TDR Time Delay Relay X X X X X X X X X X X X KAAWS0101AAA Winter Start Kit X X X X X X X X X X X X KSALA0801AAA MotorMasterr 230v X X X X X X X X X KSALA0901AAA MotorMasterr 460v X X X 53DS --- 900 --- --- --- 087 Wind Baffle X X 53DS --- 900 --- --- --- 071 Wind Baffle X X X X X X X 53DS --- 900 --- --- --- 088 Wind Baffle X X X 53DS --- 900 --- --- --- 075 Stacking Kit X X 53DS --- 900 --- --- --- 076 Stacking Kit X X X X X X X X X X 53DS --- 900 --- --- --- 077 Wall Mounting Kit X X 53DS --- 900 --- --- --- 078 Wall Mounting Kit X X X X X X X X X X KAALP0401PUR Pressure Switch Kit X X X X X X X X X X X X KSASH2301COP Sound Blanket Kit X X X X X X KSASH2401COP Sound Blanket Kit X X X X X X KAALS0201LLS Solenoid Valve Kit X X X X X X X X X X X X KSAHS1501AAA Capacitor Relay Start Assist X X X X X X X = Accessory ACCESSORY THERMOSTATS PART NUMBER DESCRIPTION TP-WEM01 Côr™ Thermostat TP-PRH01-A edge™ Programmable Relative Humidity Thermostat TP-PAC01 edge™ Programmable Thermostat TP-NRH01 edge™ Non-Programmable Relative Humidity Thermostat TP-NAC01 edge™ Non-Programmable Thermostat TC-WHS01 Wi-Fi® Thermostat TC-PAC01 Programmable Thermostat TC-NAC01 Non-Programmable Thermostat TCSNAC01 Non-Programmable Standard Screen Thermostat THERMOSTAT ACCESSORIES TP-EXP edge™ EXP® Card Programmable edge™ thermostats TSTATCCSEN01-B Outdoor Air Temperature Sensor TP-Pxx, TP-Nxx TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) - 10 pack All Carrier® branded thermostats TX-MBP01 Medium Decorative Backplate TC-Nxx TX-LBP01 Large Decorative Backplate TP-Pxx, TP-Nxx, TC-Pxx 01/22/2018 6 ACCESSORY USAGE GUIDELINE Accessory REQUIRED FOR LOW---AMBIENT COOLING APPLICATIONS (Below 55F / 12.8C) REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 ft. / 24.38 m) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km) Ball Bearing Fan Motor Standard Standard Standard Compressor Start Assist Capacitor and Relay Yes Yes No Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Liquid Line Solenoid Valve No See Long---Line Application Guideline No Low Ambient Pressure Switch or MotorMasterController Yes No No * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline Application Guideline. Accessory Description and Usage (Listed Alphabetically) 1. Ball--Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when using MotorMasterr 2. Compressor Start Assist -- Capacitor and Relay Start capacitor and relay gives a ”hard” boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single--phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 4. Evaporator Freeze Thermostat An SPST temperature--actuated switch that stops unit operation when evaporator reaches freeze--up conditions. Usage Guideline: Required when low ambient kit has been added. 5. Low--Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low--ambient temperatures down to 0_F(--18_C) when properly installed. Usage Guideline: A Low--Ambient Pressure Switch or MotorMasterr Low--Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). Suggested for all commercial applications. 6. MotorMaster Low--Ambient Controller A fan--speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated condensing temperatures down to --20_F (--28.9_C), it maintains condensing temperature at 100_F+/--10_F (37.8_C +/-- 6_C) Usage Guideline: A MotorMaster Low--Ambient Controller or Low--Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). Suggested for all commercial applications. 01/22/2018 7 ELECTRICAL DATA U NIT SIZE --- voltage,series V/PH OPER VOLTS*COMPR FAN MCA MAX FUSE** or CKT BRK AMPSMAXMINLRARLAFLA 18---30 208/230/1 253 197 56.3 9.0 0.50 11.8 20 24---30 62.9 10.9 0.50 14.1 25 30---30 73.0 14.1 0.70 18.3 30 36---30 77.0 14.1 1.20 18.8 30 48---30 124.0 18.5 1.20 24.3 40 60---30 152.5 23.7 1.45 31.1 50 36---50 208/230/3 253 197 71.0 9.0 1.20 12.5 20 48---50 83.1 13.7 1.20 18.3 30 60---50 110.0 15.9 1.45 21.4 35 36---60 460/3 506 414 38.0 5.6 0.60 7.6 15 48---60 41.0 6.2 0.60 8.4 15 60---60 52.0 7.1 0.80 9.7 15 LEGEND: FLA --- Full Load Amps HACR --- Heating, Air Conditioning, Refrigeration LRA --- Locked Rotor Amps NEC --- National Electrical Code RLA ---RatedLoadAmps(compressor) * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time --- Delay fuse. Complies with 2007 requirements of ASHRAE Standards 90.1 A--WEIGHTED SOUND POWER (dBA) Unit Size Standard Rating (dBA) Typical Octave Band Spectrum (dBA, without tone adjustment) 125 250 500 1000 2000 4000 8000 18 69 50.5 57.0 59.5 64.5 60.5 53.5 43.0 24 66 50.5 58.5 60.5 59.5 56.5 51.0 41.5 30 68 55.5 59.5 61.5 63.5 60.0 58.0 49.5 36 71 59.5 59.5 62.0 65.5 63.5 62.0 55.0 48 70 57.5 59.5 64.0 66.0 63.0 60.5 54.5 60 73 60.0 61.5 64.5 67.0 66.0 65.5 58.0 NOTE: Tested in accordance with AHRI Standard 270---08 (not listed in AHRI). A--WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHIELD Unit Size Standard Rating (dBA) Typical Octave Band Spectrum (dBA, without tone adjustment) 125 250 500 1000 2000 4000 8000 18 68 52.5 58.0 58.5 64.5 59.5 52.5 42.5 24 65 54.5 57.5 59.5 59.0 56.0 50.5 40.5 30 68 55.0 60.0 61.5 62.5 60.0 58.0 49.5 36 71 59.5 59.5 62.5 65.0 63.0 61.5 55.0 48 70 57.5 59.5 63.0 65.0 62.5 60.0 54.0 60 73 61.0 62.0 64.0 67.0 65.5 65.5 57.5 NOTES: Tested in accordance with AHRI Standard 270---08 (not listed in AHRI). Accessory sound shield will not accommodate unit sizes 18 and 24. CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE) UNIT SIZE---SERIES REQUIRED SUBCOOLING °F (°C) 18 12 (6.7) 24 12 (6.7) 30 12 (6.7) 36 8 (4.4) 48 12 (6.7) 60 10 (5.6) 01/22/2018 8DIMENSIONS -- ENGLISH01/22/2018 9DIMENSIONS -- SI 01/22/2018 10 TESTED AHRI COMBINATION RATINGS* NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Carrier database at:www.MyCarrierRatings.com For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment performance calculator can be accessed at :http://rpmob.wrightsoft.com/ Outdoor Model Number Indoor Coil Model Number Furnace Model Number Capacity EER SEER 24AHA418A30 CNPV*3014AL*+TDR 18,000 12.2 14 24AHA424A30 CNPV*3117AL*+TDR 24,000 12.2 14 24AHA430A30 CNPV*3117AL*+TDR 29,600 12.2 14 24AHA436A30 CNPV*3717AL*+TDR 35,400 12.2 14 24AHA436A50 CNPV*3717AL*+TDR 35,400 12.2 14 24AHA436A60 CNPV*3717AL*+TDR 35,400 12.2 14 24AHA448A30 CNPV*6024AL*+TDR 45,000 11.7 14 24AHA448A50 CNPV*6024AL*+TDR 45,000 11.7 14 24AHA448A60 CNPV*6024AL*+TDR 45,000 11.7 14 24AHA460A30 CNPV*6124AL*+TDR 57,000 11.7 14 24AHA460A50 CNPV*6124AL*+TDR 57,000 11.7 14 24AHA460A60 CNPV*6124AL*+TDR 57,000 11.7 14 EER — Energy Efficiency Ratio SEER — Seasonal Energy Efficiency Ratio TXV — Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are significantly affected. 01/22/2018 11DETAILED COOLING CAPACITIESEVAPORATOR AIRCONDENSER ENTERING AIR TEMPERATURES ° F (° C)75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7)CFMEWB°F(°C)Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**TotalSens‡TotalSens‡TotalSens‡TotalSens‡TotalSens‡TotalSens‡24AHA418A30 Outdoor Section With CNPV*3014AL* Indoor Section52572 (22.2)21.4910.921.1820.5510.571.3119.5610.211.4518.509.831.6117.369.431.7916.129.002.0067 (19.4)19.4313.311.1818.5812.961.3117.6712.601.4516.7112.221.6115.6811.821.7914.5711.392.0063 (17.2)17.9612.781.1817.1512.431.3116.3112.061.4515.4311.691.6114.4811.291.7913.4610.862.0062 (16.7)17.6815.681.1816.9115.331.3116.1114.961.4515.2814.561.6114.4814.481.7913.6513.652.0057 (13.9)17.1717.171.1816.5516.551.3115.9115.911.4515.2115.211.6114.4614.461.7913.6313.632.0060072 (22.2)21.9311.501.2120.9411.141.3419.9010.771.4818.7910.381.6417.619.971.8216.329.532.0367 (19.4)19.8414.221.2118.9413.871.3418.0013.501.4817.0013.111.6315.9312.701.8214.7812.262.0363 (17.2)18.3413.631.2117.5113.271.3316.6312.901.4715.7012.511.6314.7212.101.8213.6511.662.0362 (16.7)18.1416.911.2117.3616.531.3316.6116.611.4715.8615.861.6315.0515.051.8214.1514.152.0357 (13.9)17.9517.951.2117.2917.291.3316.5916.591.4715.8415.841.6315.0215.021.8214.1314.132.0367572 (22.2)22.2512.051.2421.2211.691.3620.1511.311.5019.0010.911.6617.7810.501.8516.4610.052.0667 (19.4)20.1515.111.2419.2214.741.3618.2514.371.5017.2213.971.6616.1213.551.8514.9413.092.0663 (17.2)18.6414.451.2417.7714.081.3616.8613.701.5015.9113.301.6614.9012.881.8413.8112.422.0562 (16.7)18.6318.631.2417.9217.921.3617.1817.181.5016.3816.381.6615.5115.511.8414.5614.562.0657 (13.9)18.6018.601.2417.8917.891.3617.1517.151.5016.3616.361.6615.4915.491.8414.5514.552.06EVAPORATOR AIRCONDENSER ENTERING AIR TEMPERATURES ° F (° C)75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7)CFMEWB°F(°C)Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**TotalSens‡TotalSens‡TotalSens‡TotalSens‡TotalSens‡TotalSens‡24AHA424A30 Outdoor Section With CNPV*3117AL* Indoor Section70072 (22.2)28.6214.231.5827.3313.771.7525.9513.301.9424.4812.802.1522.9012.262.4021.2111.702.6767 (19.4)26.0617.531.5724.8817.081.7423.6316.601.9322.3016.092.1420.8715.562.3919.3314.992.6763 (17.2)24.2016.871.5723.1116.411.7421.9615.941.9220.7315.442.1419.4114.912.3817.9914.342.6662 (16.7)23.8020.791.5722.7420.321.7321.6519.831.9220.5820.582.1419.5119.512.3818.3318.332.6657 (13.9)23.2923.291.5722.4422.441.7321.5321.531.9220.5520.552.1419.4819.482.3818.3118.312.6680072 (22.2)29.1114.991.6227.7614.531.7926.3314.041.9824.8013.532.1923.1612.992.4321.4112.422.7167 (19.4)26.5318.751.6125.3018.291.7824.0017.801.9722.6117.282.1821.1316.742.4319.5416.162.7063 (17.2)24.6818.011.6123.5317.541.7722.3317.061.9621.0516.552.1819.6716.002.4218.2115.422.7062 (16.7)24.3922.421.6123.4023.401.7722.4222.421.9621.3621.362.1820.2020.202.4218.9418.942.7057 (13.9)24.2824.281.6123.3623.361.7722.3922.391.9621.3221.322.1820.1720.172.4218.9118.912.7090072 (22.2)29.4615.721.6628.0715.251.8326.5914.762.0125.0114.242.2323.3313.692.4721.5313.112.7567 (19.4)26.8819.931.6525.6119.461.8224.2718.962.0122.8418.432.2221.3217.872.4619.7017.272.7463 (17.2)25.0419.111.6523.8518.631.8122.6018.142.0021.2817.612.2119.8717.052.4618.3816.432.7462 (16.7)25.1525.151.6524.1624.161.8123.1123.112.0021.9821.982.2220.7520.752.4619.4219.422.7457 (13.9)25.1125.111.6524.1324.131.8123.0823.082.0021.9521.952.2220.7320.732.4619.3919.392.74See notes on pg. 13 01/22/2018 12DETAILED COOLING CAPACITIES(CONT.)Evaporator AirCONDENSER ENTERING AIR TEMPERATURES_F(_C)75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7)CFMEWB_F(_C)Capacity MBtuh†TotalSystemKW**Capacity MBtuh†TotalSystemKW**Capacity MBtuh†TotalSystemKW**Capacity MBtuh†TotalSystemKW**Capacity MBtuh†TotalSystemKW**Capacity MBtuh†TotalSystemKW**TotalSens‡TotalSystemKW**TotalSens‡TotalSystemKW**TotalSens‡TotalSystemKW**TotalSens‡TotalSystemKW**TotalSens‡TotalSystemKW**TotalSens‡TotalSystemKW**24AHA430A30 Outdoor Section With CNPV*3117AL* Indoor Section87572 (22.2)35.2016.841.9533.6216.292.1831.9715.732.4330.1815.132.7028.2414.483.0226.1313.793.3867 (19.4)31.9920.621.9230.5620.082.1529.0619.512.4027.4418.912.6825.6718.263.0023.7517.573.3663 (17.2)29.6619.841.9028.3419.302.1326.9518.742.3725.4518.132.6623.8017.482.9822.0216.783.3562 (16.7)29.1824.361.9027.9223.822.1226.5823.242.3725.1824.972.6523.8123.812.9822.3422.343.3557 (13.9)28.3828.381.8927.3727.372.1226.2826.282.3725.0925.092.6523.7723.772.9822.3122.313.35100072 (22.2)35.9017.731.9834.2617.172.2132.5216.592.4630.6615.982.7428.6515.323.0526.4614.623.4167 (19.4)32.6522.031.9531.1721.482.1829.6020.902.4327.9120.282.7126.0819.623.0324.1018.913.3963 (17.2)30.3021.151.9328.9320.602.1627.4820.022.4025.9119.412.6924.2118.743.0122.3618.023.3762 (16.7)29.9426.261.9328.6625.662.1527.4327.432.4126.1526.152.6924.7324.733.0123.1723.173.3857 (13.9)29.6529.651.9328.5628.562.1527.3927.392.4026.1126.112.6924.7024.703.0123.1423.143.38112572 (22.2)36.4418.572.0134.7318.002.2432.9417.412.4931.0216.792.7728.9416.123.0826.7115.413.4367 (19.4)33.1823.381.9831.6422.822.2130.0122.232.4628.2821.602.7426.4020.923.0524.3820.183.4163 (17.2)30.8122.411.9629.3821.852.1927.8921.262.4326.2820.632.7224.5319.943.0422.6519.203.4062 (16.7)30.7630.761.9629.5929.592.1928.3428.342.4426.9926.992.7225.4925.493.0523.8423.843.4157 (13.9)30.7230.721.9629.5529.552.1928.3128.312.4426.9526.952.7225.4525.453.0423.8123.813.41EVAPORATOR AIRCONDENSER ENTERING AIR TEMPERATURES ° F (° C)75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7)CFMEWB°F(°C)Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**TotalSens‡TotalSens‡TotalSens‡TotalSens‡TotalSens‡TotalSens‡24AHA436A30 Outdoor Section With CNPV*3717AL* Indoor Section105072 (22.2)42.5822.262.3640.5121.512.6038.3020.712.8735.9419.873.1633.3718.973.5030.6218.013.8867 (19.4)38.7327.462.3436.8726.712.5834.8825.922.8432.7425.083.1430.4324.183.4827.9723.233.8663 (17.2)35.9626.412.3234.2425.672.5632.4024.882.8230.4324.043.1228.3123.153.4626.0322.203.8562 (16.7)35.3832.602.3233.7331.842.5632.0131.812.8230.3830.383.1228.6328.633.4626.7326.733.8557 (13.9)34.7134.712.3133.3733.372.5531.9231.922.8230.3430.343.1228.5928.593.4626.7026.703.85120072 (22.2)43.2923.462.4241.1322.692.6638.8421.882.9336.3721.023.2233.7120.103.5630.8519.133.9467 (19.4)39.4329.382.4037.4728.612.6435.4027.802.9033.1826.943.2030.7926.023.5328.2625.053.9263 (17.2)36.6428.202.3834.8327.432.6232.9226.622.8830.8725.773.1828.6724.853.5226.3323.883.9162 (16.7)36.2736.052.3834.7734.772.6233.2033.202.8931.5031.503.1929.6129.613.5327.5727.573.9257 (13.9)36.1736.172.3834.7134.712.6233.1533.152.8931.4531.453.1929.5729.573.5327.5427.543.91135072 (22.2)43.8124.602.4841.5823.822.7239.2023.002.9936.6622.133.2833.9221.203.6231.0420.234.0067 (19.4)39.9331.222.4637.9230.442.7035.7829.612.9633.5028.733.2631.0627.783.5928.4926.763.9863 (17.2)37.1429.912.4435.2829.132.6833.3028.302.9431.2027.423.2428.9426.473.5826.5825.433.9762 (16.7)37.4337.432.4435.8735.872.6834.2134.212.9532.3932.393.2530.3930.393.5928.2328.233.9857 (13.9)37.3837.382.4435.8335.832.6834.1634.162.9532.3532.353.2530.3630.363.5928.2028.203.98See notes on pg. 13 01/22/2018 13DETAILED COOLING CAPACITIES(CONT.)EVAPORATOR AIRCONDENSER ENTERING AIR TEMPERATURES ° F (° C)75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7)CFMEWB°F(°C)Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**TotalSens‡TotalSens‡TotalSens‡TotalSens‡TotalSens‡TotalSens‡24AHA448A30 Outdoor Section With CNPV*6024AL* Indoor Section140072 (22.2)54.3228.473.2251.8927.573.5349.2926.623.8846.4325.594.2943.3024.474.7639.8923.275.3067 (19.4)49.5435.143.1947.3534.253.4945.0033.303.8542.4332.284.2539.6031.164.7236.5129.955.2663 (17.2)46.0633.823.1644.0532.943.4741.8932.003.8239.5230.984.2236.9029.874.6934.0428.665.2362 (16.7)45.4441.733.1543.5340.823.4641.4839.823.8139.3739.374.2237.2237.224.7034.8034.805.2457 (13.9)44.5444.543.1542.9742.973.4641.2441.243.8139.3239.324.2237.1737.174.7034.7634.765.24160072 (22.2)55.1729.903.3052.6428.993.6149.9228.013.9646.9626.964.3743.7225.834.8440.1924.615.3867 (19.4)50.3637.463.2748.0936.553.5745.6435.593.9342.9734.534.3440.0533.394.8136.8632.135.3463 (17.2)46.8635.983.2444.7735.093.5542.5134.123.9040.0533.084.3137.3531.934.7734.4030.675.3162 (16.7)46.5144.793.2444.6444.643.5542.7942.793.9040.7340.734.3138.4238.424.7935.8335.835.3357 (13.9)46.3046.303.2444.6044.603.5542.7342.733.9040.6740.674.3138.3738.374.7935.7935.795.33180072 (22.2)55.7931.253.3853.1630.323.6950.3629.344.0447.3128.274.4543.9727.124.9240.3725.895.4667 (19.4)50.9839.683.3548.6238.753.6546.1037.764.0143.3736.694.4240.3735.504.8937.1434.185.4263 (17.2)47.4738.043.3245.3037.123.6342.9836.133.9840.4535.064.3937.6933.874.8634.7032.545.3962 (16.7)47.8047.803.3245.9945.993.6344.0044.003.9941.8141.814.4039.3639.364.8836.6436.645.4257 (13.9)47.7447.743.3245.9345.933.6343.9543.953.9941.7641.764.4039.3239.324.8736.6036.605.41EVAPORATOR AIRCONDENSER ENTERING AIR TEMPERATURES ° F (° C)75 (23.9)85 (29.4)95 (35)105 (40.6)115 (46.1)125 (51.7)CFMEWB°F(°C)Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**Capacity MBtuhTotalSysKW**TotalSens‡TotalSens‡TotalSens‡TotalSens‡TotalSens‡TotalSens‡24AHA460A30 Outdoor Section With CNPV*6124AL* Indoor Section175072 (22.2)68.8634.684.0965.7333.574.4862.3732.404.9358.6831.125.4554.6529.756.0450.2128.266.7167 (19.4)62.8142.854.0360.0141.764.4257.0040.604.8753.6939.345.3950.0537.965.9846.0336.466.6563 (17.2)58.4141.243.9955.8540.174.3853.1139.034.8250.0637.785.3446.7036.415.9342.9834.906.5962 (16.7)57.6150.933.9855.1749.824.3752.5848.594.8249.9349.935.3447.1547.155.9444.0044.006.6157 (13.9)56.5356.533.9754.5354.534.3752.3252.324.8249.8649.865.3447.0947.095.9443.9443.946.61200072 (22.2)69.9436.444.1966.6635.314.5863.1434.105.0459.3232.815.5655.1431.416.1550.5629.906.8167 (19.4)63.8445.704.1460.9344.594.5357.7843.404.9854.3442.105.4950.5940.696.0846.4539.146.7563 (17.2)59.4343.904.0956.7642.804.4853.8741.624.9350.7240.345.4447.2538.936.0343.4237.376.7062 (16.7)58.9854.674.0956.6656.664.4854.2854.284.9451.6151.615.4648.6348.636.0645.2745.276.7357 (13.9)58.7658.764.0956.5856.584.4854.2054.204.9351.5551.555.4648.5748.576.0545.2245.226.73225072 (22.2)70.7038.104.2967.3036.944.6863.6835.725.1459.7334.415.6655.4432.996.2550.7731.466.9167 (19.4)64.6148.424.2461.5947.284.6358.3546.065.0854.8244.745.5950.9843.276.1846.7941.646.8563 (17.2)60.1846.424.1957.4145.294.5854.4544.095.0351.2142.775.5547.6641.316.1343.7939.656.8062 (16.7)60.6660.664.2058.3458.344.5955.7955.795.0552.9652.965.5749.8149.816.1746.2546.256.8457 (13.9)60.5860.584.2058.2758.274.5955.7255.725.0552.9052.905.5749.7549.756.1746.2046.206.84{Total and sensible capacities are net capacities. Blower motor heat has been subtracted.}Sensible capacities shown are based on 80_F(27_C) entering air at the indoor coil. For sensible capacities at other than 80_F(27_C), deduct 835 Btuh(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F(27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F(27_C).** System kw is total of indoor and outdoor unit kilowatts.EWB— Entering Wet BulbNOTES:1. Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240---2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation incapacity may occur.2. When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. 01/22/2018 14 CONDENSER ONLY RATINGS SST °F(°C) CONDENSER ENTERING AIR TEMPERATURES °F (°C) 55 (12.78)65 (18.33)75 (23.89)85 (29.44)95 (35.0)105 (40.56)115 (46.11)125 (51.67) 24AHA418A30 30 (---1.11) TCG 16.60 15.60 14.70 13.80 12.90 12.00 11.10 10.10 SDT 68.50 78.00 87.50 97.00 106.50 116.00 125.40 134.70 KW 0.76 0.87 0.99 1.11 1.25 1.40 1.59 1.80 35 (1.67) TCG 18.30 17.20 16.30 15.30 14.30 13.30 12.30 11.20 SDT 69.70 79.20 88.70 98.20 107.60 117.00 126.30 135.50 KW 0.76 0.87 0.99 1.11 1.25 1.41 1.59 1.80 40 (4.44) TCG 20.00 19.00 17.90 16.90 15.80 14.70 13.60 12.40 SDT 71.10 80.50 89.90 99.40 108.70 118.00 127.20 136.30 KW 0.77 0.88 0.99 1.11 1.25 1.41 1.59 1.80 45 (7.22) TCG 22.00 20.80 19.70 18.50 17.40 16.20 14.90 13.60 SDT 72.50 81.90 91.30 100.60 109.80 119.00 128.20 137.20 KW 0.77 0.88 0.99 1.12 1.26 1.41 1.59 1.80 50 (10.0) TCG 24.00 22.80 21.60 20.40 19.10 17.80 16.40 15.00 SDT 74.00 83.40 92.60 101.90 111.00 120.10 129.20 138.20 KW 0.77 0.88 0.99 1.12 1.26 1.41 1.59 1.80 55 (12.78) TCG 26.30 25.00 23.60 22.30 20.90 19.50 18.00 16.40 SDT 75.60 84.80 94.10 103.20 112.30 121.30 130.30 139.20 KW 0.78 0.88 1.00 1.12 1.26 1.42 1.60 1.80 24AHA424A30 30 (---1.11) TCG 21.40 20.20 19.00 17.80 16.60 15.40 14.20 12.90 SDT 71.90 81.30 90.70 100.00 109.30 118.50 127.70 136.80 KW 1.01 1.15 1.30 1.46 1.64 1.85 2.09 2.36 35 (1.67) TCG 23.50 22.20 20.90 19.60 18.30 17.00 15.60 14.20 SDT 73.50 82.80 92.10 101.30 110.50 119.60 128.70 137.70 KW 1.02 1.16 1.30 1.47 1.65 1.86 2.09 2.37 40 (4.44) TCG 25.70 24.40 23.00 21.60 20.20 18.70 17.20 15.60 SDT 75.10 84.30 93.50 102.60 111.80 120.80 129.80 138.80 KW 1.02 1.16 1.31 1.47 1.66 1.86 2.10 2.38 45 (7.22) TCG 28.20 26.70 25.20 23.70 22.10 20.50 18.90 17.10 SDT 76.70 85.90 95.00 104.10 113.10 122.10 131.00 139.80 KW 1.03 1.17 1.32 1.48 1.66 1.87 2.11 2.39 50 (10.0) TCG 30.80 29.20 27.50 25.90 24.20 22.40 20.60 18.70 SDT 78.50 87.50 96.60 105.60 114.60 123.40 132.20 140.90 KW 1.04 1.18 1.32 1.49 1.67 1.88 2.12 2.39 55 (12.78) TCG 33.60 31.80 30.10 28.30 26.40 24.50 22.40 20.30 SDT 80.30 89.30 98.30 107.20 116.10 124.90 133.50 142.00 KW 1.05 1.18 1.33 1.50 1.68 1.89 2.13 2.40 24AHA430A30 30 (---1.11) TCG 27.20 25.80 24.40 22.90 21.40 19.70 17.90 16.00 SDT 69.90 79.20 88.60 98.00 107.30 116.60 125.80 134.80 KW 1.22 1.39 1.57 1.77 2.00 2.27 2.58 2.94 35 (1.67) TCG 30.10 28.50 27.00 25.40 23.70 21.90 20.00 17.90 SDT 71.20 80.60 89.90 99.20 108.50 117.70 126.80 135.80 KW 1.22 1.40 1.58 1.78 2.01 2.28 2.58 2.94 40 (4.44) TCG 33.10 31.40 29.70 28.00 26.20 24.30 22.20 20.00 SDT 72.70 82.00 91.20 100.50 109.70 118.90 127.90 136.90 KW 1.23 1.41 1.59 1.80 2.03 2.29 2.59 2.94 45 (7.22) TCG 36.50 34.50 32.70 30.80 28.80 26.80 24.50 22.10 SDT 74.30 83.50 92.70 101.90 111.00 120.10 129.10 137.90 KW 1.25 1.43 1.61 1.82 2.05 2.31 2.60 2.95 50 (10.0) TCG 40.00 37.90 35.80 33.80 31.60 29.40 27.00 24.40 SDT 76.00 85.10 94.20 103.40 112.40 121.40 130.30 139.00 KW 1.27 1.45 1.64 1.84 2.07 2.33 2.62 2.95 55 (12.78) TCG 43.80 41.40 39.20 36.90 34.60 32.10 29.50 26.70 SDT 77.90 86.90 95.90 104.90 113.90 122.80 131.50 140.20 KW 1.29 1.47 1.66 1.87 2.09 2.35 2.64 2.97 See notes on page 15 01/22/2018 15 CONDENSER ONLY RATINGS CONTINUED SST °F(°C) CONDENSER ENTERING AIR TEMPERATURES °F (°C) 55 (12.78)65 (18.33)75 (23.89)85 (29.44)95 (35.0)105 (40.56)115 (46.11)125 (51.67) 24AHA436A30 30 (---1.11) TCG 31.40 29.80 28.20 26.40 24.60 22.70 20.60 18.50 SDT 68.70 78.10 87.50 96.80 106.20 115.50 124.70 134.00 KW 1.48 1.69 1.91 2.14 2.40 2.69 3.04 3.44 35 (1.67) TCG 34.70 32.90 31.10 29.20 27.20 25.10 22.80 20.50 SDT 70.00 79.30 88.60 97.90 107.20 116.40 125.60 134.80 KW 1.48 1.70 1.91 2.15 2.41 2.70 3.05 3.45 40 (4.44) TCG 38.20 36.20 34.20 32.10 29.90 27.60 25.20 22.60 SDT 71.30 80.50 89.80 99.10 108.30 117.40 126.50 135.60 KW 1.49 1.70 1.92 2.16 2.42 2.72 3.06 3.45 45 (7.22) TCG 42.00 39.80 37.60 35.30 32.90 30.30 27.70 24.80 SDT 72.80 81.90 91.10 100.30 109.40 118.50 127.50 136.40 KW 1.50 1.72 1.94 2.18 2.44 2.73 3.07 3.46 50 (10.0) TCG 46.00 43.60 41.10 38.60 36.00 33.20 30.20 27.20 SDT 74.40 83.40 92.50 101.60 110.60 119.60 128.50 137.30 KW 1.52 1.74 1.96 2.20 2.46 2.75 3.08 3.47 55 (12.78) TCG 50.20 47.60 44.90 42.10 39.20 36.20 32.90 29.60 SDT 76.10 85.00 94.00 103.00 111.90 120.80 129.50 138.20 KW 1.54 1.76 1.98 2.22 2.48 2.77 3.10 3.48 24AHA448A30 30 (---1.11) TCG 41.50 39.50 37.40 35.40 33.20 30.80 28.20 25.40 SDT 73.40 82.60 91.90 101.20 110.40 119.50 128.60 137.50 KW 2.05 2.30 2.57 2.87 3.21 3.60 4.05 4.56 35 (1.67) TCG 45.70 43.40 41.20 38.90 36.50 33.90 31.10 28.10 SDT 75.10 84.30 93.40 102.60 111.70 120.80 129.70 138.60 KW 2.08 2.33 2.60 2.90 3.24 3.63 4.08 4.60 40 (4.44) TCG 50.10 47.70 45.20 42.70 40.10 37.20 34.20 30.90 SDT 77.00 86.00 95.10 104.10 113.20 122.10 131.00 139.70 KW 2.12 2.36 2.63 2.93 3.27 3.67 4.12 4.64 45 (7.22) TCG 54.80 52.20 49.50 46.70 43.80 40.70 37.40 33.80 SDT 78.90 87.80 96.80 105.80 114.70 123.50 132.20 140.80 KW 2.15 2.39 2.66 2.96 3.31 3.71 4.16 4.69 50 (10.0) TCG 59.90 56.90 54.00 51.00 47.80 44.40 40.70 36.80 SDT 80.90 89.80 98.60 107.50 116.30 125.00 133.60 142.00 KW 2.19 2.43 2.70 3.00 3.34 3.74 4.20 4.72 55 (12.78) TCG 65.20 62.00 58.80 55.40 51.90 48.20 44.20 39.90 SDT 83.10 91.80 100.50 109.30 117.90 126.50 134.90 143.20 KW 2.24 2.47 2.73 3.03 3.38 3.78 4.24 4.76 24AHA460A30 30 (---1.11) TCG 53.00 50.30 47.70 45.10 42.40 39.40 36.00 32.40 SDT 76.00 85.10 94.30 103.50 112.70 121.70 130.60 139.40 KW 2.59 2.90 3.23 3.61 4.03 4.52 5.08 5.71 35 (1.67) TCG 58.30 55.30 52.50 49.70 46.60 43.30 39.70 35.70 SDT 78.00 87.00 96.10 105.20 114.20 123.10 131.90 140.60 KW 2.64 2.94 3.28 3.65 4.08 4.58 5.14 5.78 40 (4.44) TCG 63.90 60.70 57.60 54.50 51.10 47.50 43.60 39.30 SDT 80.00 88.90 97.90 106.90 115.80 124.70 133.30 141.90 KW 2.69 2.99 3.32 3.70 4.14 4.63 5.20 5.84 45 (7.22) TCG 70.00 66.50 63.10 59.60 55.90 51.90 47.60 42.90 SDT 82.20 91.00 99.90 108.80 117.60 126.30 134.80 143.20 KW 2.74 3.04 3.38 3.76 4.19 4.69 5.27 5.91 50 (10.0) TCG 76.40 72.60 68.80 65.00 60.90 56.50 51.80 46.70 SDT 84.60 93.30 102.00 110.70 119.40 127.90 136.30 144.50 KW 2.80 3.10 3.43 3.81 4.25 4.76 5.33 5.97 55 (12.78) TCG 83.30 79.10 74.90 70.60 66.10 61.30 56.10 50.60 SDT 87.00 95.60 104.20 112.80 121.20 129.60 137.80 145.80 KW 2.86 3.15 3.49 3.87 4.31 4.82 5.39 6.04 * AHRI listing applies only to systems shown in Combination Ratings table. KW --- Outdoor Unit Kilowatts Only. SDT --- Saturated Temperature Leaving Compressor (°F) SST --- Saturated Temperature Entering Compressor (°F/°C) TCG --- Gross Cooling Capacity (1000 Btuh) 01/22/2018 16 GUIDE SPECIFICATIONS GENERAL System Description Outdoor--mounted, air--cooled, split--system air conditioning unit suitable for ground or rooftop installation. Unit consists of a scroll--type hermetic compressor, an air--cooled coil, propeller--type condenser fan, and a control box. Unit will discharge supply air horizontally as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or furnace. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210. — Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c--UL approval. — Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500--hr salt spray test. — Air--cooled condenser coils will be leak tested and pressure tested — Unit constructed in ISO9001 approved facility. Delivery, Storage, and Handling — Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. PRODUCTS Equipment — Factory assembled, single piece, air--cooled air conditioning unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puronr (R--410A), and special features required prior to field start--up. Unit Cabinet — Unit cabinet will be constructed of galvanized steel and bonderized. Fans — Condenser fan will be direct--drive propeller type, discharging air horizontally. AIR--COOLED, SPLIT--SYSTEM AIR CONDITIONER 24AHA4 1--1/2 TO 5 NOMINAL TONS — Condenser fan motors will be totally enclosed, 1--phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Compressor — Compressor will be a scroll--type, hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed. Refrigeration Components — Refrigeration circuit components will include liquid--line front--seating shutoff valve with sweat connections, vapor--line front--seating shutoff valve with sweat connections, system charge of Puronr (R--410A) refrigerant, and compressor oil. — Unit will be equipped with high--pressure switch, low pressure switch and filter drier for Puron refrigerant. Operating Characteristics — The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of ______F/_C. The power consumption at full load will not exceed _____ kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at ______F/_Cwet bulb and ______F/_C dry bulb, and air entering the unit at ______F/_C. — The system will have a SEER of _____ Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. — Nominal unit electrical characteristics will be _____ v, three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. Copyright 2015 Carrier Corp.S 7310 W. Morris St.S Indianapolis, IN 46231 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: 24AHA4---02PD Replaces: 24AHA4---01PD Edition Date: 03/15 01/22/2018 9FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM EV-SERIES & GRSpecifications may be subject to change without notice. INDOOR UNIT SPECIFICATIONS Ventilation Type: Static plate, heat and humidity transfer Typical Airflow Range: 50-140 CFM Standard Features: Painted cabinet Line-cord power supply Low-voltage circuit for controls Unit may be mounted in any orientation Controls: Onboard 24 VAC transformer/relay package with switched dry contacts Filters: Total qty. 2, MERV 8, spun-polyester media: 10 1/2" x 10 1/2" x 1" Unit Dimensions & Weight: 33 1/2" L x 13 1/4" W x 20" H 48 lbs. Max. Shipping Dimensions & Weight (in carton): 32" L x 22" W x 18" H 60 lbs. Motor(s): Qty. 1, Double-shaft standard motor Accessories: Backdraft damper 6" Wall cap 6" - white, brown Percentage timer control (PTL) Push-button point-of-use controls (PBL), PTL req'd. Percentage timer control with furnace interlock (FM) 6" Typ. 8 1/8" 5 1/2" Typ. 9" OA EA RA FA 34" Line Cord 28 3/4" Case 33 1/4" Overall 2 1/4" Typ. 6 3/8" Typ. 13 1/8" Overall(with HangingBracket) 4 1/8" Typ. 18 1/8"Case 2 5/8" 7/8" 8" NominalTyp.21 3/4" Overall(with HangingBracket)6" Nominal Typ. 20" Overall 12 7/8" Case 11 1/4" MinimumService Area (Door can beRemoved from Hinges.)18 1/2"MinimumService Area 17 1/2" Door Swing 24V AC Control TerminalLEFT VIEW FRONT VIEW RIGHT VIEW TOP VIEW Model: EV130Drawing Type: Unit DimensionVersion: MAR16 ABBREVIATIONSEA: Exhaust Air to outsideOA: Outside Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside INSTALLATION ORIENTATIONUnit may be installed in any orientation. NOTE1.UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE ROUNDED TO THENEAREST EIGHTH OF AN INCH. 2.SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. UNIT DIMENSIONS EV-SERIES & GRAIRFLOW CONFIGURATION Available as shown in dimension drawing. UNIT MOUNTING & APPLICATION Can be mounted in any orientation. RA/EA airstream can be switched with OA/FA airstream. ELECTRICAL DATA HP Volts HZ Phase Input Watts FLA 0.1 120 60 Single 102 @ 130 CFM 1.3 UNIT PERFORMANCE CORE PERFORMANCE Airflow CFM ESP in H20 Temp EFF%Total EFF% Winter/Summer* 79 0.60 78 73/60 104 0.50 75 69/55 126 0.40 72 66/50 137 0.30 71 64/48 153 0.20 68 61/45 165 0.10 67 59/43 * See HVI certification ratings on page 148 of RenewAire’s Full Line Volume XVII Catalog. Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on the EV130. 130EV Energy Recovery Ventilator Standard Download specification at: renewaire.com/specifications 01/22/2018 RENEWAIRE.COM 1.800.627.4499 6 SPECIFICATIONS & DIMENSIONS Specifications may be subject to change without notice. INDOOR UNIT SPECIFICATIONS Ventilation Type: Static plate, heat and humidity transfer Typical Airflow Range: 40-110 CFM Standard Features: Galvanized cabinet Terminal strip hard wiring in ebox (no line cord) Unit may be mounted in any orientation Control: Can use any switched line-voltage power supply (no low-voltage controls) Filters: Total qty. 2, MERV 8, spun-polyester media: 9 5/8" x 10 1/2" x 1" Unit Dimensions: & Weight 22 1/2" L x 11 3/4" W x 23 3/4" H 36 lbs. Max. Shipping Dimensions & Weight (in carton): 29" L x 22" W x 15" H 40 lbs. Motor(s): Qty. 2, Standard motorized impeller blowers Accessories: Backdraft damper 6" Wall cap 6" - white, brown 120V line voltage Honeywell control 5 7/8" Typ. 11 3/4" Overall(with HangingBracket) 18" Case 2 1/4" Typ. 22 1/2" Overall Power Wiring Inlet 7/8"6 1/4"Typ.11 3/4"Typ.5 3/4"Typ.OA EA RA FA 11 5/8"Case 23 3/4"Overall10 1/8" Minimum Service Area (Door can beRemoved from Hinges.)22 1/4" MinimumService Area 21 1/4" Door Swing 2 5/8" 7/8" Typ. 21 7/8" Case 6" Nominal Typ. 8" Nominal Typ.25 1/2" Overall(with Hanging bracket)Formed Inlet Ring LEFT VIEW FRONT VIEW RIGHT VIEW TOP VIEW Model: GR90Drawing Type: Unit DimensionVersion: MAR16 ABBREVIATIONSEA: Exhaust Air to outsideOA: Outside Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside INSTALLATION ORIENTATIONUnit may be installed in any orientation. NOTE1.UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE ROUNDED TO THENEAREST EIGHTH OF AN INCH. 2.SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. UNIT DIMENSIONS AIRFLOW CONFIGURATION Available as shown in dimension drawing. UNIT MOUNTING & APPLICATION Can be mounted in any orientation. RA/EA airstream can be switched with OA/FA airstream. ELECTRICAL DATA HP Volts HZ Phase Input Watts FLA 0.03 120 60 Single 46 @ 90 CFM 0.35 UNIT PERFORMANCE CORE PERFORMANCE Airflow CFM ESP in H20 Temp EFF%Total EFF% Winter/Summer* 40 0.60 84 74/56 58 0.50 80 69/50 73 0.40 77 65/46 85 0.30 74 62/43 98 0.20 71 59/39 113 0.10 68 56/34 * See HVI certification ratings on page 148 of RenewAire’s Full Line Volume XVII Catalog. Note: Electric Duct Heater and Indirect Gas-Fired Duct Furnace are not available on the GR90. 90GR Energy Recovery Ventilator Standard Download specification at: renewaire.com/specifications 01/22/2018 01/22/2018 01/22/2018 01/22/2018 01/22/2018 01/22/2018 01/22/2018 01/22/2018 01/22/2018 A United Technologies Company Carrier 0. 01/22/2018 IInnvviissiiLLiinneeaarr ®® TTHHEE AAEESSTTHHEETTIICC CCHHOOIICCEE 01/22/2018 01/22/2018 01/22/2018 01/22/2018 01/22/2018 AIR HORIZONS LLC IN NYS: AIR HORIZONS CORPORATION PO BOX 1369 MEREDITH, NH 03253-1369 USA PH & FAX: 888-808-2580 InvisiLinear ® #LBG-724-PSF SERIES INSTALLATION INSTRUCTION Installation: Openings larger than 1 bay should be framed. Raw end or hemmed edge (no flange) plenum should terminate at the inside of the framing to allow slip-in. Diffuser is fastened directly to the framing via c/s screws (not shown) through the sub flange. Non standard wall thicknesses may require adjustments or spacing as required. Blueboard may be undercut as required to accommodate the sub flange. Blue board should be scored or beaded all around frame if necessary and plaster feathered in. A fine plaster line at the grille border is the key to a first class installation. Standard cores are removable through the face of the diffuser via concealed screws. Both standard finishes - white and clear anodized - are paintable without further treatment. Black- out construction, if ordered, should be rollered to avoid paint spray on the blackened support components. Opposed blade damper (#OBD) and pattern controller (#SDG-H), if required, duct mount separately behind the diffuser. LBG-724-INSTALLATION 01/22/2018 01/22/2018 01/22/2018 01/22/2018 01/22/2018 01/22/2018 Louvered Supply Grilles and Registers • Aero-Blade Series Steel Border • Aluminum Airfoil Blades Models: 272RL • Double Deflection • Long Front Blades • 3/4” Blade Spacing 272RS • Double Deflection • Short Front Blades • 3/4” Blade Spacing D minus 1/2" D plus 1 3/4" D minus 3/4" Nominal Duct Size D " 9/16" 1 1/4" 3/4" 1 13/16" 1/4" 3 9/16" Optional Opposed Blade Damper TITUS®Submittal ABG-272R 5-1-95 Available Sizes (D” x D”) Note:Dimensions are in inches. Wall or duct opening should be duct size ±1/8.” Border Type 1 • Surface Mount Mounting Frames 1 5/8 5/16 3/8 Duct + 1/16 Duct + 1 13/16 1/4 Duct + 2 7/16 Duct Size 1 1/4 Duct Size - 3/4 Duct 1/4 Available with Border Type 1 only. Single deflection blades shown for clarity. Type A • External Screw Type C • Concealed Screw PFAP • Aluminum Plaster Frame Note:Wall opening should be listed duct size + 1/8” to listed duct size + 1/4”. Model PFAP Plaster Frame can be installed as either surface mount or recessed. Fastenings Opposed blade damper (galvanized steel) IS • Insect Screen (1/16” square mesh – galvanized steel) DS • Debris Screen (1/4” square mesh – galvanized steel) Accessories (Optional) Check if provided3 EQT • Earthquake Tabs Other Finish: ______________________ Standard Finish:#26 White Other: __________________________ General Description • Aerodynamically shaped blades are individu- ally adjustable. • Optional opposed blade damper has screw- driver adjustment accessible through face of register. • Material is 20 gauge steel for border and heavy extruded aluminum for blades. • #8 x 11/4” lg. Phillip’s flat head sheet metal screws painted white. • All dimensions are ±1/16”. TITUS® 990 Security Row • Richardson, Texas 75081 • 972-699-1030 • Fax 972-918-8880 ABG-2.0-S All rights reserved. No part of this work may be reproduced or transmitted in any form or any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system without permission in writing from Tomkins Industries, Inc. Note: This submittal is meant to demonstrate general dimensions of this product. The drawings on this submittal are not meant to detail every aspect of the product with exactness. Drawings are not to scale. TITUS reserves the right to make changes without written notice. Recessed Mounted Example Border Type 1 is available in sizes 6” x 4” through 48” x 48” in one piece construction. Sizes larger than 48” x 48” are shipped in multiple sections with joining strips for field assembly. Odd and fractional sizes are available at additional cost.01/22/2018 mr.steam®steambaths Technical Specifications Model MS Super 3E Serial Number 9000000 and higher Mr.Steam Standard Features •Stainless steel resevoir •Industrial,large diameter,serviceable heating element •Modular “snap-in”connections •Electronic water-level control system •Full-port drain valve. •Limited lifetime steam generator parts warranty Safety Features •UL recognized electronic controller system •Built-in,low-voltage 24-volt control •60-minute electronic countdown with 75-minute limiting safety back-up •ASME safety valve Locating and installing the Steam Generator Unit •Select a location as near as practical to the steam room,within 50 feet. Typical locations include:closet,vanity cabinet,heated attic or basement. •Do not install steambath generator inside the steam room. •Do not install steambath generator outdoors or wherever environmental conditions may affect the safety and/or performance of the generator. •Do not install steambath generator or plumbing lines in unheated attic or any locations where water could freeze. •Do not install steambath generator near flammable or corrosive materials or chemicals or in areas having a high concentration of chlorine. •Install steambath generator on a solid and level surface or securely mounted to a wall using the keyhole slots provided. •Install steambath generator in an upright position only. •Provide a minimum of (12)inches at both ends and top of the steam generator or as required for servicing. Refer to Mr.Steam Installation,Operation and Maintenance Manual PUR 101289 REV 10.08 or later for complete instructions. Required Plumbing Water Supply (3/8"NPT)Steam Outlet (1/2"NPT) Safety Valve (3/4"NPT)Drain (1/2"NPT) Steam Head (1/2"NPT) •Locate steam head 6–12 inches above floor. •For tub/shower enclosures,install 6 inches above tub top edge. •Consult with supplier of acrylic,fiberglass and other non-heat resist- ant enclosures for recommended steamhead location.An acrylic shield is available for these installations (part number 103938). Electrical All electrical wiring to be installed by a qualified licensed electrician in accordance with National Electrical Code and local electrical code. Power Wiring 1.Check power voltage.Use 240V rated unit when supply is greater than 208V.(Most homes have 240V,1PH service).Use 208V rated unit for 208V power. 2.Use minimum 90˚C/300V rated insulated copper conductors only, type THHN or equal sized in accordance with National Electrical Code and local electrical code for the Amps in Ampere Chart.If allowed by code,NM cable may require a larger wire size than as listed on the chart. 3.Connect suitably sized equipment grounding wire to ground terminal provided. 4.Install a separate circuit breaker between supply and unit.Provide a power supply disconnect within sight of the steam generator or one that is capable of being locked in the open position. 5.For single phase units,use two-wire supply source and equipment grounding wire.Neutral (white)wire is not required. †All specifications shown are for 208V and 240V,single phase. Consult factory for other voltage specifications. ††See power wiring,note 2 above. AMPERE CHART max room volts wire size model no.vol.cu.ft.kw 1 ph†amps (awg)†† MS Super 3E 675 15.0 208 73 4 240 63 4 01/22/2018 17" (432)23/8" (60) 4" (102) 13/8" (35) 77/8" (200) 71/4" (184) 10" (254) 121/2" (310) 183/4" (466) 13/4" (45) 6" (152) 63/8" (162) 21/2" (64) 17" (432)23/8" (60) 4" (102) 13/8" (35) 77/8" (200) 71/4" (184) 10" (254) 121/2" (310) 183/4" (466) 13/4" (45) 6" (152) 63/8" (162) 21/2" (64) Water Inlet Control & Accessory Connections Steam Outlet Safety Valve Optional AutoFlush Side View Showing Element Access Panel Manual Drain Valve NOTES: 1.M=Optional AutoFlush 2.All units in inches (MM) IMPORTANT NOTE: Provide a minimum of twelve (12)inches at both ends and top of the steam generator or as required for servicing.Alternately,provide unions as required to facilitate installation and disconnection of the steam generator. IMPORTANT NOTE: The minimum clearance from combustible surfaces is zero all around. IMPORTANT NOTE: Do not rough in plumbing and electrical services based in the dimensional information provided. Drawings are not to scale. TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO HEATING ELEMENTS !!! NOTE:FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT:See Mr.Steam®Installation,Operation and Maintenance Manual,PUR 101289,for details.Click here to download this manual: http://mrsteam.com/products/technical-downloads.html mr.steam®steambaths Technical Specifications Model MS Super 3EGeneratorDiagram 2 01/22/2018 Stainless Steel Indirect Water Heaters Lochinvar.com 12 Squire Models to Choose From - 6 Standard Models from 30 to 119 Gallons - 6 Solar Models from 65 to 119 Gallons 316L Passivated Stainless Steel Tank 316L High Capacity Stainless Steel Coil Fully Welded Construction 01/22/2018 Laser Cut Precision A CNC laser uses Programmable Logic Controls to precisely cut the Squire Indirect Water Heater’s tank shell out of 14 gauge 316L stainless steel to a tolerance of .01 inch. 2 The Squire Stainless Steel Indirect Water Heater -- with 12 models to choose from in capacities from 30-119 gallons, we are sure to have the right size indirect water heater to fit your application. Squire features important enhancements that our customers will recognize and benefit from such as a welded and passivated stainless steel tank and heat exchanger, two-inch thick, high-density insulating foam, and best of all an American made product built in Lebanon, Tennessee. LASER Cut Precision Robotic Welder Passivated for Protection - a new Class of Water Heater Tank Cylinder Roller The computer controlled tank cylinder rolling machine ensures that the 316L stainless steel is transformed into a geometrically perfect cylinder. Coil Winder Straight tubes are rolled by a seven axis coil winder and turned into a precise, round coil used in the indirect water heater to transfer the BTU’s from the heat source to the potable water stored in the tank. Robotic Welder This state of the art six axis programmable robotic welder uses computer guidance to accurately weld the stainless steel fittings to the tank. Hydrostatic Leak Test After welding, the tank is hydrostatically pressure tested to ensure quality conformance. Passivation Process Each tank is subjected to a soaking spray of nitric acid. This treatment washes away any iron that was left behind during the welding process and re-establishes the oxide level of the stainless steel to ensure corrosion resistance. By removing iron from the welded surfaces, the Squire is less susceptible to corrosion brought on by aggressive water. Jacket and Foam The dent resistant polypropylene jacket and ABS caps are attached to the tank assembly, and then high density foam is added using a high pressure dispensing system to provide insulation that will keep the heat where it belongs, in the water. The result is a tank that is jacketed and evenly foam insulated with standby losses as low as 0.5°F per hour.Foam Insulation Process Stainless Steel Tank Manufacturing 01/22/2018 3 316L Passivated Stainless Steel Tank 316L Stainless Steel material is used for the tank interior for superior durability and long life. The rust prohibitive characteristics of this material make it the perfect material to resist the corrosive tendencies of domestic water. The passivation process consists of a treatment method that enhances and increases the superior corrosion resistance of stainless steel. 316L High Capacity Stainless Steel Coil The Squire’s 316L Stainless Steel heating coil efficiently transfers high volumes of BTU’s from the heat source to the domestic water with high first hour delivery capability. Built in the U.S.A. at Lochinvar’s World Headquarters A 100% stainless steel indirect water heater built in the USA, the Squire is completely assembled in Lebanon, Tennessee. Outstanding Features Inside Look Stainless Steel SIT Indirect How it Works Combine the Knight Heating Boiler with the Squire Indirect for the perfect combination for your application. Dent resistant polypropelene jacket*Temperature & pressure relief valve Sensor well 316L Stainless Steel coil High density foam insulation Cold water inlet Boiler water outlet Boiler water inlet The Squire uses the power and efficiency of the building’s heating boiler or solar array to generate domestic hot water for showers, dishwashing, clothes washing or any potable hot water demand. The efficiency of the heating boiler could be as much as 20% higher than a direct-fired tank-type water heater. So, why not use that efficiency to “indirectly” provide hot water for all potable applications? By using the Squire to indirectly heat the domestic water, you eliminate the additional gas line, electrical connections and vent ducts needed with direct-fired tank-type water heaters. Six Standard Models from 30 to 119 Gallons The highest quality indirect water heater in the market also has one of the widest ranges of gallon capacities. With 6 models covering gallon capacities from 30 to 119 gallons the Squire is one of the broadest lines available. Six Solar Models from 65 to 119 Gallons With three dual coil models for solar heating in conjunction with a heat source and three models with a solar coil and an electric element the Squire line of water heaters has a model to fit any residential or light duty commercial solar application. 100% Stainless Steel Construction Squire Water Heaters are constructed with Stainless Steel materials that are highly resistant to corrosion that can result from poor water quality. *SET models feature metal jacket 01/22/2018 Fully Welded Construction Lochinvar utilizes state of the art, highly accurate robotic welding equipment that results in a fully welded construction method that requires no gaskets or mechanical sealing methods. Gaskets and seals are the weak point of any water storing appliance, therefore Lochinvar’s advanced design eliminates this potential failure point. Factory Supplied Tank Sensor (SIT and SDT only) A tank sensor with built in temperature limit is standard equipment on all sizes. This sensor accurately monitors the water temperature and sends a call for heat when the tank temperature drops below the desired setpoint. This sensor is 100% compatible and can be directly connected with Lochinvar’s line of KNIGHT or Cadet Heating Boilers. T&P Relief Valve Supplied with the unit in the carton. (shipped loose) High Density CFC/HCFC Free Polyurethane Foam Two inches of R-13.4 High Density Polyurethane foam yields the lowest standby losses in the industry. Attractive Rust Resistant Jacket Resistant to scratches and dents, the Squire will maintain its classic high quality appearance for years. Limited Lifetime Warranty* Lochinvar believes that the Squire is the best built Indirect Water Heater on the market, we have a Limited Lifetime warranty to prove it. *SIT models only Stainless Steel SIT Indirect Solar Indirect with SET Electric Back-upSolar Indirect with SDT Dual Coil Squire Indirect Water Heaters with a single coil and an electric element are designed to collect heat from a solar array and transfer the collected heat into the stored water by way of the indirect coil which is located in the lower portion of the tank. An electric element, which is controlled by a factory supplied thermostat, is positioned in the top half of the tank to ensure ample hot water even at times when the solar array is not capable of collecting the heat required by the DHW demand. Squire Indirect Water Heaters with a dual coil design have a coil in the lower portion of the tank to transfer heat from a solar array to the water that is stored in the tank. An additional coil in the upper portion of the tank will transfer heat from a back-up boiler into the water. This will ensure that the tank has ample hot water even at times when the solar array cannot generate enough heat to suitably heat the tank. 01/22/2018 Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt. (lbs.) SIT030 39-1/2” 20” 32-1/4” 21-3/4” 8-1/4” 3” 1” 1” 79 SIT040 55-3/4” 20” 48-1/2” 25-1/4” 8-1/4” 3” 1” 1” 105 SIT050 48” 24” 39-3/4” 24-1/2” 9-1/4” 3-3/4” 1” 1” 131 SIT065 60” 24” 52-1/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 147 SIT080 69-1/2” 24” 61-3/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 177 SIT119 69” 28” 60-1/4” 31-3/4” 9-1/4” 3-1/4” 1-1/2” 1” 213 Heat Source Standby First Continuous 1st Hour Min. Flow Friction Model Capacity Water Volume Loss Draw Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (°F/Hr) Gals. (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SIT030 27 1.1 1.5 24 160 183 99,000 14.0 3.9 SIT040 40 1.6 0.9 27 181 208 115,000 14.0 4.5 SIT050 52 1.7 0.9 47 209 255 133,000 14.0 5.3 SIT065 67 1.9 0.7 65 263 327 154,000 14.0 5.7 SIT080 82 2.1 0.6 74 266 347 160,000 14.0 5.7 SIT119 114 3.2 0.5 109 349 459 200,000 14.0 6.5 Performance data is based on I=B=R test results. All ratings are based on 180°F boiler water temperature with incoming cold water at 50°F and a Delta T of 77°F. Includes tank sensor for use with KNIGHT or Cadet Heating Boiler. Optional thermostat available for use with other boiler models. SIT MODELS All models standard with a Lifetime Limited Warranty Against Tank Failure. All parts are warranted for one year. Five year limited tank warranty on all models when installed in a commercial application. Stainless Steel Indirect SIT Models Dimensions and Specifications TRIM AREAThe “Hot Water Outlet” connection is Female NPT. All other connections are Male NPT. 01/22/2018 Solar Stainless Steel Indirect Dimensions and Specifications PDP-7.5M-3/15–Printed in U.S.A.SIT-02 (Reprint SIT-02 4/14) Stainless Steel Indirect Water Heaters A D G H I FROMPANEL TOPANEL COLD WATERINLET SOLARSENSORWELL Domestic Coil Model Water Connection Shipping Number A B D E F G H I Conn. Size Wt. (lbs.) SDT065 60” 24” 52-1/4” 47-1/4” 33-3/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 158 SDT080 69-1/4” 24” 61-3/4” 53-3/4” 40-1/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 188 SDT119 68” 28” 60-1/4” 54-1/2” 37-1/2” 31-3/4” 9-1/4” 3-1/4” 1-1/2” 1” 224 Heat Boiler Heat Standby Continuous 1st Hour Min. Flow Friction Model Capacity Source Water Source Water Loss Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (Gallons) (°F/Hr) (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SDT065 66 2.1 1.7 0.7 175 205 128,000 14.0 3.4 SDT080 79 2.1 1.7 0.6 175 208 128,000 14.0 3.4 SDT119 110 3.2 2.6 0.5 251 301 181,000 14.0 4.9 Performance data based on incoming cold water at 50°F and a Delta T of 77°F. Delivery ratings for boiler coil only. Includes tank sensor for use w/ KNIGHT Heating Boiler. Domestic CoilModel Water Connection ShippingNumber A B D G H I Conn. Size Wt. (lbs.) SET065 60” 24” 52-1/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 149 SET080 69-1/2” 24” 61-3/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 179 SET119 68-1/4” 28” 60-1/4” 31-3/4” 9-1/4” 3-1/4” 1-1/2” 1” 215 Electric Electric Heat Source Standby Continuous 1st HourModel Capacity Water Loss Delivery DeliveryNumber (Gallons) (Gallons) (°F/Hr) (GPH) (Gallons) SET065 67 1.9 0.7 24 54 SET080 81 2.1 0.6 24 57 SET119 113 3.2 0.5 24 75 All SET models: 4500w 240v 1 phase. SDT Models Dimensions and Specifications SET Models Dimensions and Specifications A D G H I FROMPANEL TOPANEL COLD WATERINLET SOLARSENSORWELL SDT Models SET Models SET & SDT MODELS All models standard with a 5 year Limited Warranty Against Tank Failure. All parts are warranted for one year. *SET models only The “Hot Water Outlet” connection is Female NPT. All other connections are Male NPT. Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com 01/22/2018