Loading...
HomeMy WebLinkAboutFile Documents.805 Roaring Fork Rd.0019.2018 (26).ARBKDEW POINT CALCULATION JOB NAME: 805 Roaring Fork Road JOB NUMBER: 17089.00 DATE: 1/18/18 CALCS BY: JSW DP @ DP @ DP @ DP @ DP @ 20% RH 25% RH 30% RH 35% RH 45% RH 30 33 37 41 48 0 Indoor design temperature (IDT)70 70 R-value 0.17 0.00 0.00 0.94 30.15 0.00 19.00 0.56 0.61 51.43 20.17 43 41 YES Note: To minimize the potential for condensation problems, humidity levels within the home must be properly controlled and adjusted based on outdoor temperatures. DPA = Dew point at point A (35% RH) Roof Underlayment 3/4" plywood 4.5" spray foam insulation (R-6.7/in) Outdoor design temperature (ODT) Delta T = IDT - ODT Layer Thermal Resistance of Proposed Roof Assembly Outside air layer Roofing Batt Insulation (5.5") Is TA warmer than the DPA? Inside air layer R-Total R-value at A A: point of condensation analysis Vapor barrier 5/8" gypboard TA = IDT - (R-value at A)/(R-Total) * (Delta T) TA = Temperature at point A NOMINAL R-49 ROOF INSULATION 1/18/2018 01/22/2018