Loading...
HomeMy WebLinkAboutFile Documents.RACE ST.0220.2018 (4).ARBKG:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc over City of Aspen and Pitkin County FIREPLACE & WOODSTOVE REGISTRATION *Required—Contact Assessors offices at 920-5160 Registration will not be accepted without a Parcel Id number List all devices in your home (2 are allowed per building, except for gas appliances) Note: If the number, type and location on this registration form do not match what is show on your plans or what is actually installed, your permit or Certificate of Occupancy will be denied. Type of Building (circle one): Reside ntial Other Type of device Room Existing New Make & Model Wood burning fireplace (select one) ?Site-built masonry ?Factory built insert: model number: _____________________ Gas log fireplace (select one) ?Site-built masonry ?Factory built insert: model number: _____________________ Certified woodstove Gas fireplace appliance (attach spec sheet) If any devices are being removed, please describe here, i.e. “old woodstove removed from living room” · __________________________________________________________________________________ · __________________________________________________________________________________ · __________________________________________________________________________________ _______________________________________________________ ____________________________ Signature of applicant Date *Parcel Id number:____ ____ ____ ____ -- ____ ____ ____ -- ____ ____ -- ____ ____ ____ Street Address:_________________________________________________________________________ Owners Name:_________________________________________________________________________ 2737-073-92-005 549 RACE ALLEY ASPEN MARCH LLC OLD GAS FIREPLACE APPLIANCE REMOVED FROM SITTING ROOM. ENTERTAINMENT RM 002 SITTING ROOM 106 MASTER BEDROOM 201 X X X MAJESTIC MARQUIS II 36 8.16.2018 09/04/2018 Specifications MARQ36IN Please consult the manufacturer’s installation manual for all details and requirements before making a final design layout decision. MARQUIS II 36 Direct Vent Gas Fireplace 61" [1549] 31-1/16" [789] 40-11/16" [1035] 57-5/8" [1464]41-3/8" [1051] 59-1/4" [1505] 16" [406] 29-5/8" [752] 3-7/8" [98] 2-3/4" [70] 16-1/8" [410] 10-7/8" [276] Gas Access Electrical Access 24" [610] 23-1/2" [597]Heat-Zone® Port Heat-Zone® Port 54-15/16" [1395] 1-5/16"[33 mm]3-5/8"[92 mm] 40-11/16"[1035 mm] 36-13/16"[935 mm] 35-9/16"[903 mm] MODEL HEIGHT FRONT WIDTH BACK WIDTH DEPTH GLASS SIZE MARQ36IN Actual Framing Actual Framing Actual Framing Actual Framing 35-7/8" x 31-1/16" [911 X 789]57-5/8" [1464] 56" [1422] 61" [1549] 59-1/2" [1511] 59-1/4" [1505] 59-1/2" [1511] 24" [610] 24" [610] TOP VIEW FRONT VIEWLEFT SIDE RIGHT SIDE DECORATIVE FRONT 09/04/2018 Specifications MARQ36IN MAJ/MARQUISII_MARQ36IN_0917(800) 927-6841 • www.majesticproducts.com APPLIANCE LOCATION WALL PENETRATION MANTEL LEG/WALL PROJECTIONS 105"[2667] 26-1/2"[673] 26-1/2"[673] 29-3/4"[756] 29-3/4"[756] 59-1/2"[1511] 59-1/2" [1511] 59-1/2"[1511] 23-1/2"[597] 23-1/2"[597] 74-1/4" [1886] 74-1/4"[1886] FRAMING DIMENSIONS CLEARANCES TO COMBUSTIBLES 24"[610] 56" [1422] 59-1/2" [1511] 10"[254] 1 46 3 6 12 9 49 52 55 58 FIREPLACE OPENING MAX. MIN. MANTEL PROJECTIONS 74-3/16"* 73-3/16" 10"12" Do not pack with insulationor other material. *Shows center of vent framing hole with minimum vertical for top venting. Center of hole is 1" above center of horizontal vent pipe.*Add height for chase deeper than 24". 7" min Fireplaceopening Combustible ornon-combustible wall Combustible ornon-combustible wall 14" min 14" min Combustiblecolumn Non-combustiblecolumn 4" maximum Factory-suppliednon-combustibleboard Fireplaceopening Factory-suppliednon-combustibleboard 6" maximumSee section 13.Efor requiredclearances 1/2" Building material 1/2" Building material Combustible Mantel Non-combustible Mantel 0" 1"[25]1"[25] See install manualsection 3.D 36"[914] 52"[1321] from appliance opening to ceiling 87-3/16" [2215] from bottom of fireplace to ceiling Note: A 12" non-combustible hearth extension is required. The replace may be raised from the oor a minimum of 3" to eliminate this requirement. See installation manual for more details. 13Heat & Glo • TRUE-36, TRUE-42, TRUE-50 Installation Manual • 2282-980 Rev. L • 1/16 Non-Combustible Zone Figure 3.7 Non-Combustible Zone NO COMBUSTIBLES IN HATCHED AREA 1/2" BUILDING MATERIAL (MAY BE COMBUSTIBLE) FACTORY-SUPPLIED 1/2"NON-COMBUSTIBLE BOARD PIPE IS FOR VISUAL REFERENCE ONLY 1" = COMBUSTIBLES NOT ALLOWED 39" 2" x 4" OR GREATER FRAMING MATERIAL NOTE: 2" x 4" HEADER CONFIGURATION 2" x 4" ONLY IN GRAY AREA PRODUCT LISTING CODES US ANSI Z21.88-2009 CAN CSA 2.33-2009 UL307B Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury. NON-COMBUSTIBLE ZONE Combustible Mantel Projections shown. See installation manual for Non-combustible Mantel Projections Note: All measurements in inches. Note: Measurement is taken from bottom of appliance. Note: Measurement from fireplace opening to bottom of appliance is 35-3/16". 1/2 IN NON-COMBUSTIBLE MATERIAL 09/04/2018